Factors That Cause Concerns after Cardioverter Defibrillator Implantation
Abstract
:1. Introduction
2. Materials and Methods
2.1. Study Design and Setting
2.2. Study Participants and Selection
- -
- Stage I aimed at a clinical examination with data collection and analysis before ICD implantation. Additionally, specific questionnaires were completed (DS-14 scale—Scale for Measuring a Type-D Personality, Acceptance of Illness Scale (AIS), Hospital Anxiety Depression Scale (HADS) and the Athens Insomnia Scale (AIS)).
- -
- Stage II consisted of a follow-up appointment after six months ± two weeks following ICD insertion. The occurrence of any ICD interventions, hospital admissions or complications were reviewed. The previous questionnaires were again completed, including the ICD Patient Concern Questionnaire (ICDC) [9].
2.3. Ethical Considerations
2.4. Research Instruments
2.5. Statistical Analyses
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
Study Limitation
References
- Priori, S.; Blomström-Lundqvist, C.; Mazzanti, A.; Blom, N.; Borggrefe, M.; Camm, J.; Elliott, P.; Fitzsimons, D.; Hatala, R.; Hindricks, G.; et al. ESC Scientific Document Group. 2015 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: The Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC) Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Eur. Heart J. 2015, 36, 2793–2867. [Google Scholar] [PubMed] [Green Version]
- Zungsontiporn, N.; Loguidice, M.; Daniels, J. Important parameters for implantable cardioverter defibrillator selection. Card. Elektrophysiol. Clin. 2018, 10, 145–152. [Google Scholar] [CrossRef] [PubMed]
- Raczak, G.; Sominka, D. Indications for implantation of a cardioverter-defibrillator. Forum Med. Rodz. 2009, 3, 165–172. [Google Scholar]
- Stern, S. Michele Mirowski. Folia Cardiol. Experta 2006, 1, 175–176. [Google Scholar]
- El-Battrawy, I.; Roterberg, G.; Liebe, V.; Ansari, U.; Lang, S.; Zhou, X.; Borggrefe, M.; Akin, I. Implantable cardioverter-defibrillator in Brugada syndrome: Long-term follow up. Clin. Cardiol. 2019, 42, 958–965. [Google Scholar] [CrossRef] [PubMed]
- Pedersen, S.; Theuns, D.; Erdman, R.; Jordaens, L. Clustering of device-related concerns and type D personality predicts increased distress in ICD patients independent of shocks. Pacing Clin. Electrophysiol. 2008, 31, 20–27. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Mańkowska-Załuska, B.; Nowek, A.; Topolska, E.; Oszczygieł AChudzik, M.; Wranicz, J. Psychological problems of patients after cardioverter-defibrillator implantation. Folia Cardiol. 2015, 10, 342–347. [Google Scholar] [CrossRef]
- The EHRA White Book 2017: The Current Status of Cardiac Electrophysiology in ESC Member Countries. Available online: https://www.escardio.org/static-file/Escardio/Subspecialty/EHRA/Publications/Documents/2017/ehra-white-book-2017.pdf (accessed on 12 September 2020).
- Karczewska, O.; Młynarska, A. The influence of antiarrhythmic device intervention on biopsychosocial functioning and anxiety in patients with an implantable cardioverter defibrillator. Medicina 2021, 57, 113. [Google Scholar] [CrossRef]
- Frizelle, D.; Lewin, B.; Kaye, G.; Moniz-Cook, E.D. Development of a measure of the concerns held by people with implanted cardioverter defibrillators: The ICDC. Br. J. Health Psychol. 2006, 11, 293–301. [Google Scholar] [CrossRef]
- Młynarska, A.; Młynarski, R.; Uchmanowicz, I.; Marcisz-Dyla, E.; Marcisz, C.; Gołba, K. Cross-cultural adaptation and reliability testing of the Implantable Cardioverter-Defibrillator Concerns questionnaire to optimize the care of Polish patients with implantable cardioverter-defibrillators. Kardiol. Pol. 2020, 9, 906–912. [Google Scholar] [CrossRef]
- Denollet, J. DS14: Standard Assessment of Negative Affectivity, Social Inhibition and Type D Personality. Psychosom. Med. 2005, 67, 89–97. [Google Scholar] [CrossRef] [PubMed]
- Mazurek, J.; Lurbiecki, J. Acceptance of Illness Scale and Its Clinical Impact. Pol. Merkur. Lek. Organ Pol. Tow. Lek. 2014, 36, 106–108. [Google Scholar]
- Snaith, P. The hospital anxiety and depression scale. Health Qual. Life Outcomes 2003, 29, 1–4. [Google Scholar]
- Watrowski, R.; Rohde, A. Validation of the Polish version of the Hospital Anxiety and Depression Scale in three populations of gynecologic patients. Arch. Med. Sci. AMS 2014, 10, 517–524. [Google Scholar] [CrossRef]
- Fornal-Pawłowska, M.; Wołyńczyk-Gmaj, D.; Szelenberger, W. Validation of the Polish version of the Athens Insomnia Scale. Psychiatr. Pol. 2011, 45, 211–221. [Google Scholar] [PubMed]
- R Core Team. R: A Language and Environment for Statistical Computing. R Foundation for Statistical Computing; R Core Team: Vienna, Austria, 2020. [Google Scholar]
- Pedersen, S.; van der Broek, K.; Erdman, R.; Jordaens, L.; Theuns, D. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator. Europace 2010, 12, 1446–1452. [Google Scholar] [CrossRef] [PubMed]
- Pedersen, S.; van Domburg, R.; Theuns, D.; Luc Jordaens, L.; Erdman, R. Concerns about the implantable cardioverter defibrillator: A determinant of anxiety and depressive symptoms independent of experienced shocks. Am. Heart J. 2005, 149, 664–669. [Google Scholar] [CrossRef]
- Versteeg, H.; Timmermans, I.; Meine, M.; Zitron, E.; Mabo, P.; Denollet, J. Prevalence and risk markers of early psychological distress after ICD implantation in European REMOTE-CIED study cohort. Int. J. Cardiol. 2017, 240, 208–213. [Google Scholar] [CrossRef] [Green Version]
- Pedersen, S.; Hoogwegt, M.; Jordaens, L.; Theuns, D. Pre-implantation psychological functioning preserved in majority of implantable cardioverter defibrillator patients 12 months post implantation. Int. J. Cardiol. 2013, 166, 215–220. [Google Scholar] [CrossRef] [PubMed]
- Starrenburg, A.; Pedersen, S.; den Broek, K.; Kraaier, K.; Scholten, M.; Palen, J. Gender differences in psychological distress and quality of life in patients with an ICD1-Year postimplant. Pacing Clin. Electrophysiol. 2014, 37, 843–852. [Google Scholar] [CrossRef] [PubMed]
- Vazquez, L.D.; Kuhl, E.A.; Shea, J.B.; Kirkness, A.; Lemon, J.; Whalley, D.; Conti, J.; Sears, S. Age-specific differences in women with Implantable Cardioverter Defibrillators: An international multicenter study. Pacing Clin. Electrophysiol. 2008, 31, 1528–1534. [Google Scholar] [CrossRef] [PubMed]
Parameter | Value |
---|---|
Age (years) | 67.61 ± 9.15 |
BMI (kg/m2) | 29.01 ± 5.84 |
SBP (mmHg) | 123.32 ± 12.87 |
DBP (mmHg) | 74.8 ± 8.93 |
EF (%) | 29.75 ± 8.34 |
HR (bpm) | 72.84 ± 9.29 |
Marital status: | |
Single | 47 (29.7%) |
Married/living with partner | 111 (70.2%) |
Education: | |
None or primary | 6 (3.8%) |
Vocational | 93 (58.9%) |
Secondary | 41 (25.9%) |
Higher | 18 (11.4%) |
Disease: | |
Heart Failure (NYHA I-IV) | 140 (88.6%) |
Hypertension | 129 (81.6%) |
Stroke | 14 (8.8%) |
Ischemic Heart Disease | 123 (77.8%) |
COPD | 18 (11.3%) |
Obesity | 71 (44.9%) |
Thyroid Disease | 20 (12.6%) |
Diabetes | 67 (42.4%) |
Medications: | |
β-blocker | 156 (98.1%) |
ACE | 144 (91.1%) |
MRA | 147 (93%) |
Statins | 136 (86%) |
Oral antidiabetic drugs | 63 (39.8%) |
Insulin | 26 (16.45%) |
Number | Question I Am Worried About: | Not at All N (%) | A Little Bit N (%) | Somewhat N (%) | Quite a Lot N (%) | Very Much So N (%) |
---|---|---|---|---|---|---|
1. | My ICD firing | 40 (25.31%) | 53 (33.54%) | 26 (16.45%) | 22 (13.92%) | 17 (10.75%) |
2. | My ICD not working when I need it to | 52 (32.91%) | 59 (37.34%) | 34 (21.51%) | 8 (5.06%) | 5 (3.16%) |
3. | What I Should do if my ICD fires | 67 (42.40%) | 53 (33.54%) | 29 (18.35%) | 7 (4.43%) | 2 (1.26%) |
4. | Doing exercise in case it causes my ICD to fire | 109 (68.98%) | 27 (17.08%) | 15 (9.49%) | 5 (3.16%) | 2 (1.26%) |
5. | Doing activities/hobbies that may cause my ICD to fire | 83 (52.53%) | 35 (22.15%) | 17 (10.75%) | 11 (6.96%) | 12 (7.59%) |
6. | My heart condition getting worse if the ICD fires | 106 (67.08%) | 27 (17.08%) | 11 (6.96%) | 8 (5.06%) | 6 (3.79%) |
7. | The amount of time I spend thinking about my heart condition and having an ICD | 144 (91.13%) | 10 (6.32%) | 4 (2.53%) | 0 (0%) | 0 (0%) |
8. | The amount of time I spend thinking about my ICD firing | 143 (90.5%) | 10 (6.32%) | 5 (3.16%) | 0 (0%) | 0 (0%) |
9. | The ICD battery running out | 108 (68.35%) | 28 (17.72%) | 14 (8.86%) | 5 (3.16%) | 3 (1.89%) |
10. | Working too hard/overdoing things and causing my ICD to fire | 76 (48.1%) | 37 (23.41%) | 22 (13.92%) | 12 (7.59%) | 11 (6.96%) |
11. | Making love in case my ICD fires | 104 (65.82%) | 30 (18.98%) | 13 (8.22%) | 6 (3.79%) | 5 (3.16%) |
12. | Having no warning that my ICD will fire | 32 (20.25%) | 60 (37.97%) | 20 (12.65%) | 24 (15.18%) | 22 (13.92%) |
13. | The symptoms/pain associated with my ICD firing | 59 (37.34%) | 36 (22.78%) | 20 (12.65%) | 20 (12.65%) | 23 (14.55%) |
14. | Being a burden on my partner/family | 106 (67.08%) | 23 (14.55%) | 17 (10.75%) | 5 (3.16%) | 7 (4.43%) |
15. | Not being able to prevent my ICD from firing | 126 (79.74%) | 8 (5.06%) | 11 (6.96%) | 8 (5.06%) | 5 (3.16%) |
16. | The future now that I have an ICD | 106 (67.08%) | 16 (10.12%) | 14 (8.86%) | 14 (8.86%) | 8 (5.06%) |
17. | Problems occurring with my ICD, e.g., battery failure | 86 (54.43%) | 29 (18.35%) | 22 (13.92%) | 12 (7.59%) | 9 (5.69%) |
18. | Getting too stressed in case my ICD fires | 141 (89.24%) | 7 (4.43%) | 3 (1.89%) | 4 (2.53%) | 3 (1.89%) |
19. | Not being able to work/take part in activities and hobbies because I have an ICD | 131(82.91%) | 13 (8.22%) | 4 (2.53%) | 6 (3.79%) | 4 (2.53%) |
20. | Exercising too hard and causing my ICD to fire | 144 (91.13%) | 7 (4.43%) | 3 (1.89%) | 2 (1.26%) | 2 (1.26%) |
Parameter | Age Spearman Correlation Coefficient | |
---|---|---|
Number of concerns | r = −0.282 | p < 0.001 |
Intensity of concerns | r = −0.278 | p < 0.001 |
Overall concerns score | r = −0.28 | p < 0.001 |
Factor 1-perceived limitations | r = −0.357 | p < 0.001 |
Factor 2-device specific concerns | r = −0.209 | p = 0.008 |
Parameter | Gender—Value | ||
---|---|---|---|
Women (N = 31) | Men (N = 127) | p | |
Number of concerns | 9.84 ± 5.09 | 7.02 ± 4.8 | p = 0.006 |
Intensity of concerns | 18.81 ± 13.52 | 13.46 ± 14.19 | p = 0.012 |
Overall concerns score | 28.65 ± 17.93 | 20.48 ± 18.63 | p = 0.009 |
Factor 1—perceived limitations | 5.32 ± 5.17 | 4.9 ± 6.4 | p = 0.162 |
Factor 2—device specific concerns | 10.48 ± 7.44 | 7.14 ± 7.75 | p = 0.005 |
Parameter | Prevention—Value | ||
---|---|---|---|
Primary | Secondary | p | |
Number of concerns | 7.24 ± 4.85 | 9.48 ± 5.32 | p = 0.06 |
Intensity of concerns | 13.21 ± 13.08 | 22.13 ± 17.96 | p = 0.022 * |
Overall concerns score | 20.46 ± 17.48 | 31.61 ± 23.05 | p = 0.028 * |
Factor 1—perceived limitations | 4.46 ± 5.66 | 8.04 ± 8.03 | p = 0.016 * |
Factor 2—device specific concerns | 7.05 ± 7.12 | 12.17 ± 10 | p = 0.026 * |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Karczewska, O.; Młynarska, A. Factors That Cause Concerns after Cardioverter Defibrillator Implantation. Int. J. Environ. Res. Public Health 2021, 18, 6095. https://doi.org/10.3390/ijerph18116095
Karczewska O, Młynarska A. Factors That Cause Concerns after Cardioverter Defibrillator Implantation. International Journal of Environmental Research and Public Health. 2021; 18(11):6095. https://doi.org/10.3390/ijerph18116095
Chicago/Turabian StyleKarczewska, Olimpia, and Agnieszka Młynarska. 2021. "Factors That Cause Concerns after Cardioverter Defibrillator Implantation" International Journal of Environmental Research and Public Health 18, no. 11: 6095. https://doi.org/10.3390/ijerph18116095