Next Article in Journal
Integrated Application of GPR and Ultrasonic Testing in the Diagnostics of a Historical Floor
Previous Article in Journal
Analysis on Three-Dimensional Strength Influencing Factors and Control Measures of Asphalt Mixtures
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Elduque, A., et al. Electricity Consumption Estimation of the Polymer Material Injection-Molding Manufacturing Process: Empirical Model and Application

1
BSH Electrodomésticos España S. A., Avda. de la Industria, 49, 50016 Zaragoza, Spain
2
i+, Department of Mechanical Engineering, EINA, University of Zaragoza, C/María de Luna, 3, 50018 Zaragoza, Spain
*
Author to whom correspondence should be addressed.
Materials 2020, 13(11), 2548; https://doi.org/10.3390/ma13112548
Submission received: 20 April 2020 / Accepted: 1 June 2020 / Published: 3 June 2020
During the formatting phase of this article [1], the authors did not detect a typographical error in the equations to calculate the SEC value; they would therefore like to make the following correction in both Equations (1) and (7). There was a minus symbol missing in the super index of the η value (percentage of utilization of the injection-molding machine).
Equation (1) was wrongly formatted as:
SEC (KWh/kg) = (7.5 – 5 × E/100) × (η)0.5
Moreover, it must be corrected as the following:
SEC (KWh/kg) = (7.5 – 5 × E/100) × (η)−0.5
Equation (7) was wrongly formatted as:
SEC = (7.5 − (5 × (E/100) × (((w × 3.6/tc)/(0.0052 × Fc))0.15/(ce× (Ti − Ta)/350.255)0.1))) × (w × 100/(⍴ × Vmax))0.5
It must be corrected as the following:
SEC = (7.5 − (5 × (E/100) × (((w × 3.6/tc)/(0.0052 × Fc))0.15/(ce × (Ti − Ta)/350.255)0.1))) × (w × 100/(⍴ × Vmax))−0.5
The authors would also like to take the opportunity to apologize for any inconvenience that this typographical error may have caused in the calculations done by the readers. All the data, calculations and results are correct, but both equations were missing, in the final version, the minus symbol in the superscript, due to a formatting error.

Reference

  1. Elduque, A.; Elduque, D.; Pina, C.; Clavería, I.; Javierre, C. Electricity Consumption Estimation of the Polymer Material Injection-Molding Manufacturing Process: Empirical Model and Application. Materials 2018, 11, 1740. [Google Scholar]

Share and Cite

MDPI and ACS Style

Elduque, A.; Elduque, D.; Pina, C.; Clavería, I.; Javierre, C. Correction: Elduque, A., et al. Electricity Consumption Estimation of the Polymer Material Injection-Molding Manufacturing Process: Empirical Model and Application. Materials 2020, 13, 2548. https://doi.org/10.3390/ma13112548

AMA Style

Elduque A, Elduque D, Pina C, Clavería I, Javierre C. Correction: Elduque, A., et al. Electricity Consumption Estimation of the Polymer Material Injection-Molding Manufacturing Process: Empirical Model and Application. Materials. 2020; 13(11):2548. https://doi.org/10.3390/ma13112548

Chicago/Turabian Style

Elduque, Ana, Daniel Elduque, Carmelo Pina, Isabel Clavería, and Carlos Javierre. 2020. "Correction: Elduque, A., et al. Electricity Consumption Estimation of the Polymer Material Injection-Molding Manufacturing Process: Empirical Model and Application" Materials 13, no. 11: 2548. https://doi.org/10.3390/ma13112548