Next Article in Journal
Inhalable Mannosylated Rifampicin–Curcumin Co-Loaded Nanomicelles with Enhanced In Vitro Antimicrobial Efficacy for an Optimized Pulmonary Tuberculosis Therapy
Next Article in Special Issue
Particle-Assisted Dermal Penetration—A Simple Formulation Strategy to Foster the Dermal Penetration Efficacy
Previous Article in Journal
Peptide Targeted Gold Nanoplatform Carrying miR-145 Induces Antitumoral Effects in Ovarian Cancer Cells
Previous Article in Special Issue
Liposomal Formulations to Improve Antioxidant Power of Myrtle Berry Extract for Potential Skin Application
 
 
Article
Peer-Review Record

In Silico Prediction of Skin Permeability Using a Two-QSAR Approach

Pharmaceutics 2022, 14(5), 961; https://doi.org/10.3390/pharmaceutics14050961
by Yu-Wen Wu 1,†, Giang Huong Ta 1,†, Yi-Chieh Lung 1, Ching-Feng Weng 2 and Max K. Leong 1,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Reviewer 3: Anonymous
Pharmaceutics 2022, 14(5), 961; https://doi.org/10.3390/pharmaceutics14050961
Submission received: 4 April 2022 / Revised: 23 April 2022 / Accepted: 26 April 2022 / Published: 28 April 2022

Round 1

Reviewer 1 Report

Overall the month is well written and the results presented are satisfactory.

Author Response

Nothing needed to be done.

Reviewer 2 Report

The manuscript is interesting and the overall study design looks good.

Author Response

This manuscript has been polished by professional scientific editing service.

Reviewer 3 Report

The manuscript of Wu et al. well demonstrated the weaknesses of the various methods in the logP calculations and the necessity of the correct choice of the descriptors in QSAR methods. However, it is unclear what was the real aim of this work. Unfortunately, apart from some minor issues, there are weaknesses in the data visualizations which make the reading difficult. Before the resubmission, a native English chemist revision is also necessary.

Some points proposed for reconsideration:
- Please replace "skin permeability" and " quantitative structure-activity relationship (QSAR)" in the Keywords section because the title already contains them, and so there is no added value in this section.

- The authors wrote just in the first sentence of the Introduction, "The skin, which is the largest organ in the human body ..." In which terms are the largest? Surface, weight, etc.?

- The Δ symbol represents a difference rather than a gradient.

- Interestingly, the authors also used software more than 15-years old in their work, but the correlation between the various models and results is unclear between the softwares and the found results.

- The selection rationale of the model compounds is also unclear. There are some chemicals whose presence among the selected molecules is difficult to interpret. An example is diethyl ether. This molecule is highly volatile and has a boiling point close to the natural temperature of human skin, meaning it interacts with the skin only in extreme conditions. Only the minority of the diethyl ether can penetrate through the skin, while its majority immediately evaporates - except, of course, the soaking. Other interesting molecules are the halogenated acetic acids. They are not medicines, but it is also hard to find formulations in which these compounds are present in significant quantities.

- Although the authors defined the r^2 values in the text, the r values are in figures. The referee understands that the r values are larger than the r^2, and so the results are more attractive, but it is incorrect -  at least by the referee.

- What do the points (and lines) represent in Figure 4. It is clear that only some data points are in the figure and not the entire set, but the lines and the caption make the figure confusing. What do they represent? Are they a subset of the originals? If so, what were the criteria of selection?

- In Figure 5, two faults make it confusing. The first is that the legend does not have colors, only the circle, square, and triangle. The second is that the squares and triangles have identical colors.

- Figure 6 also contains two errors. The first is in the graph. There is an illegal "@" sign in front of the 0.78, and the second is a typo in the caption.

- The referee would suggest replacing Figure 8 with another, more informative figure. Perhaps more interesting would be the error of the logP calculations versus the measured logP.

- Figure 9 caption writes the Vm vs. 0χ, but the ordinate identifier is log Kp.

- The graphs in the SI file need separate captions because there are so many graphs that the reader can easily get lost among them.

Though the listed concerns do not have equal weights, a major revision is necessary to correct them.

Author Response

See the attached file for detail.

Author Response File: Author Response.pdf

Round 2

Reviewer 3 Report

See the attached file.

Comments for author File: Comments.pdf

Author Response

See the attached file for detail

Author Response File: Author Response.pdf

Back to TopTop