Next Article in Journal
An Elliptical-Shaped Dual-Band UWB Notch Antenna for Wireless Applications
Next Article in Special Issue
Model Test Analysis of Groundwater Level Fluctuations on Karst Cover Deformation Taking the Monolithic Structure of Guilin as an Example
Previous Article in Journal
Effectiveness of Virtual Reality Goggles as Distraction for Children in Dental Care—A Narrative Review
Previous Article in Special Issue
Diatomaceous Soils and Advances in Geotechnical Engineering—Part I
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Bearing Capacity of Shallow Foundations on Unsaturated Silty Soils

by
Mehmet Ugur Yilmazoglu
1,* and
Askin Ozocak
2
1
Institute of Natural Sciences, Sakarya University, Serdivan 54050, Turkey
2
Department of Civil Engineering, Faculty of Engineering, Sakarya University, Serdivan 54050, Turkey
*
Author to whom correspondence should be addressed.
Appl. Sci. 2023, 13(3), 1308; https://doi.org/10.3390/app13031308
Submission received: 28 December 2022 / Revised: 13 January 2023 / Accepted: 17 January 2023 / Published: 18 January 2023
(This article belongs to the Special Issue Mechanical Properties and Engineering Applications of Special Soils)

Abstract

:
In general, the ultimate bearing capacity (UBC) of shallow foundations on unsaturated soils is characterized by the conventional shear strength (SS) parameters in which saturated theories are applied. However, in this case, it is clear that the foundations designed using the obtained values from the saturated cases not be economical. In recent years, procedures have been developed to estimate the UBC of foundations on unsaturated soils, that take into account drained and undrained loading conditions. However, these studies generally concentrate on sandy soils. The validity of the results proposed in the literature should be tested for other soils. Therefore, this paper includes a conventional direct shear box (DSB) test to determine the unsaturated SS of statically compacted silty soil, and a series of model tests were performed to determine the foundation’s UBC. In the experimental model setup, the UBC values of different types and sizes of model foundations on silty soil layers with a different soil saturation degrees (SSDs)/matric suctions (MSs) and different void ratio values were measured. In addition, the soil-water characteristic curves (SWCCs) and SS parameters of unsaturated silt were obtained. Using the experimental results, a new equation is proposed for the characterization of the UBC of shallow foundations on unsaturated silty soils. Using this equation, the UBC of unsaturated soils can be determined based on the results of unconfined compressive strength tests (UC) measured on unsaturated soil samples and based on the degree of saturation and the fitting parameter. The results indicate that the measured bearing capacity values obtained via the model footing test, shows a good consistency with those obtained by the proposed equation.

1. Introduction

The design of shallow foundations involves two main objectives: determining the ultimate bearing capacity (UBC) and ensuring compliance with allowable settlement limits. Traditional methods for determining UBC and settlement behavior on saturated soils can be divided into two groups: the Effective Stress Approach [1] (ESA) and the Total Stress Approach [2] (TSA). The ESA requires effective soil parameters and uses c′ (effective cohesion) and ∅′ (effective internal friction angle), whereas the TSA is based on the ∅u = 0 analysis and is used for undrained conditions. Until recently, UBC values for footings on unsaturated soil layers were determined based on the assumption of saturated soil [1,2,3]. However, this assumption is not always accurate and can lead to non-economical solutions. To ensure a realistic design in unsaturated the soil environments, the effect of soil saturation degree (SSD)/matric suction (MS) must be taken into account. MS, which is frequently used as a measure of suction, is a critical characteristic that determines the behavior and mechanical properties of unsaturated soil [4,5,6]. Therefore, in geotechnical applications, the the MS value must be taken into account when calculating soil strength and volume changes. Capillary tension is the ability of soil to absorb and retain water and is directly related to water content [7].
Research on the behavior of unsaturated soils, which make up a large portion of the Earth’s land, has been important in recent years. The majority of shallow foundations are found in areas of unsaturated soil, depending on the depth of the groundwater table. The SS of unsaturated soils is important in the design of shallow foundations because the failure in these foundations is usually caused by exceeding the UBC value [8,9,10,11]. Therefore, research on the behavior of unsaturated soils has been prioritized over the last ten years. In the literature, experimental studies have been conducted under both drained and undrained conditions [12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29]. In general, research in this area has aimed to improve understanding of the mechanical behavior of unsaturated soils and to develop appropriate methods for assessing the bearing capacity of unsaturated soils. Studies have focused on factors such as matric suction, soil structure, and soil water content and their effects on the bearing capacity of unsaturated soils. Some studies have also investigated the use of various test methods to assess the bearing capacity of unsaturated soils, such as triaxial tests, direct shear tests, and plate load tests. Additionally, numerical models have been used to simulate the mechanical behavior of unsaturated soils. These studies have shown that the UBC values of foundations, calculated using traditional saturated soil mechanics concepts, are quite far from the UBC values of foundations on unsaturated soil conditions. Studies on the estimation of the UBC of foundations on unsaturated soil layers can be grouped under two main groups, which are similar to traditional soil mechanics groupings. These are the proposed approaches to estimate the SS of unsaturated soils under drained and undrained conditions. There are various structural models and modeling techniques that can be used for both approaches, but these models require a variety of soil parameters that necessitate complex and extensive laboratory tests. On the other hand, there are various numerical modeling techniques presented in the literature that are extended by modifying the ESA and the TSA to take into account the effect of MS [11,12,30,31,32,33,34,35,36,37]. The approaches introduced in the literature are called the Modified Effective Stress Approach (MESA) and the Modified Total Stress Approach (MTSA). These methods, which can be estimated with the test results obtained for unsaturated conditions for the MSEA and the MTSA in the literature, are simple and fast. Additionally, these numerical techniques can be verified by comparing the experimentally measured UBC values with the values obtained through the proposed equations.
Previous studies have shown that the influence of MS on soil strength is not linear [38]. MS is considered to have a non-linear, hydrostatic suction profile. The MS value can change due to changes in the water level or weather conditions, even when the groundwater level is constant [39,40]. This means that foundations on soil layers above the groundwater level may experience larger UBC values than calculations made assuming saturated conditions.
The focus of this research is to use model foundations of various forms and sizes to investigate the UBC of shallow foundations on silty soil. Strength tests and model foundation loading tests on samples with varied void ratios, saturation levels, and the MS values were conducted in order to ascertain the effect of the MS on SS and the UBC values for the unsaturated soil zone.

Estimation of UBC of Foundations on Unsaturated Soils

Several methods have been proposed in the literature for estimating the UBC of foundations on unsaturated soils. These methods mainly involve modifying the equations proposed by Terzaghi [1] and Skempton [2] to take into account the effect of matric suction. Research has shown that foundations on unsaturated soils typically fail through the punching shear failure mode [11,12,15,41]. In the case of cohesive soils, it is assumed the a constant pore water pressure under undrained conditions can provide accurate results. Tang et al. [42] also found that in-place plate bearing tests typically occur under constant water content condition, and that assuming a constant value for the effective stress parameter does not lead to errors in the results. Oh and Vanapalli [18] proposed an equation (Equation (1)) for estimating the UBC of shallow foundations on the surface of unsaturated fine-grained soil, based on the assumption of an undrained loading condition.
q u l t ( u n s a t ) = s u n s a t × ξ × N c s
where qult(unsat) = UBC of the foundation on fine-grained soil; sunsat = SS of unsaturated soil based on unconfined compressive strength (UC); ξ = shape factor; and Ncs = UBC factor under undrained loading conditions (i.e., 5,14). In the same study, Oh and Vanapalli (2013) [18] have also demonstrated that the SS of an unsaturated soil is equal to the sum of the saturated SS and the increase in SS produced by the MS (Equation (2)). In addition, it has been reported that the total SS of the unsaturated cohesive soil (including the contribution of the MS to the SS) can be obtained with the UC, so there is no need to measure the MS value of the cohesive soils [18].
s u n s a t = [ s s a t + f ( u a u w ) ] = [ q u ( u n s a t ) 2 ]
where sunsat is the SS of the soil based on the UC; f ( u a u w ) is the increase in strength with MS contribution; and qult(unsat) is the UC of the soil.
Oh and Vanapalli (2013) [18] demonstrated that the UC of fine-grained soils, and mainly of clay soils, can be used to predict the UBC of shallow square foundations (Equation (3)). A shape factor, ξunsat = 1 + 0.2B/L (where B and L corresponds to the foundation width and length, respectively) established by Meyerhof (1963) [43] and Vesic (1973) [44] for undrained circumstances, was also employed in the proposed equation:
q u l t ( u n s a t ) = [ q u ( u n s a t ) 2 ] × [ 1 + 0.2 B L ] × N u n s a t
where B is the width of the foundation; L is the length of the foundation; and Nunsat is the UBC factor in unsaturated soils, which was obtained using back analysis by Oh and Vanapalli (2013) [18].
In addition, for the estimation of the UBC of foundations on coarse-grained unsaturated soils under drained loading conditions, equations based on the modification of the UBC equation (Equation (4)) proposed by Terzaghi (1943) [1] for strip foundations on saturated soils is available in the literature [12,13,15,26,29,30,32,34].
q u l t = K 1 c N c + q N q + K 2 γ B N γ
where c′ is the effective cohesion; q is the effective vertical stress; B is the width of foundation; K1 and K2 are shape factors; and Nc, Nq and Nγ are UBC factors.
Oloo et al. (1997) [12] modified Terzaghi’s (1943) [1] effective stress approach and proposed a model that can be used to estimate the UBC of a shallow foundation on unsaturated soils, taking into account the effect of MS (Equation (5)). The model covers the situation in which both pore air and water pressure are effective during the loading phase. The model employs a fixed ∅b for suction values greater than the air-entry value (AEV) of the soil.
q u l t = { c + ( u a u w ) b t a n + [ ( u a u w ) ( u a u w ) b ] t a n b } N c + 1 2 B γ N γ
where c′ is the effective cohesion; ∅′ is the effective angle of internal friction; ∅b is the angle indicating the rate of increase in shear strength relative to the MS; ( u a u w ) b is the AEV/bubbling pressure; ( u a u w ) is the MS value; B is the width of the foundation; N c and N γ are the UBC coefficients of Terzaghi (1943) [1] and Kumbhokjar (1993) [45], respectively. Since the behavior of ∅b is non-linear beyond the AEV, this method can estimate the UBC within an acceptable range depending on the suction range. A bilinear envelope [46] can be used to simulate the nonlinear relationship between the SS and the MS, as shown in Figure 1. As can be seen from Figure 1, the contribution of MS to the SS is ∅b = ∅ for suction values less than the AEV. This region, where the SS increases linearly with the MS, is called the linear region. Beyond the AEV, the contribution of ∅b gradually decreases despite the increase in MS; therefore, ∅b is less than ∅. In this region, which is called the nonlinear region, the SS of unsaturated soils changes nonlinearly with the MS [46,47]. Such a behavior is consistent with the reason explained using Figure 1 for the SS of unsaturated soils. The red line here shows the contribution of ∅b, to the SS at MS values greater than the AEV.
Vanapalli and Mohamed (2007) [14] developed the original UBC equation for continuous footings which was based on the Terzaghi (1943) [1] equation for unsaturated soils and reference the UBC model of Oloo et al. (1997) [12], and the nonlinear shearing resistance model proposed by Vanapalli et al. (1996) [48] (Equation (6)). Vanapalli and Mohamed (2007) [14] also suggested that by using the measured shear strength angle value increased by 10% (1.1ϕ′), a more accurate estimation of the UBC value can be obtained for both saturated and unsaturated conditions.
q u l t = { [ c + ( u a u w ) b t a n S Ψ t a n ] + ( u a u w ) A V E S Ψ t a n } N c ξ c + 1 2 B γ N γ ξ γ
where c′ is the effective cohesion; ∅′ is the effective angle of internal friction; S is the degree of saturation; Ψ is the fitting parameter; ( u a u w ) b is the AEV; ( u a u w ) A V E is the average MS value; Nc and Nγ = are Terzaghi (1943) [1] and Kumbhokjar (1993) [45] bearing capacity coefficients, respectively, and ξc and ξγ = Vesic (1973) [44] shape factors.
Vanapalli and Mohamed (2007) [14] developed a correlation between the UBC fitting parameter (Ψ) and the plasticity index (Ip) based on the results of the study performed on five soils (Figure 2). All three of the sandy soils examined in the study had a fitting parameter (Ψ) = 1; however, it was noted that other fine-grained soils needed greater values. Equation 7 explains the link between the UBC fitting parameter (Ψ) and the Ip based on the findings of the research conducted on five soils.
Ψ = 0.0031 I p 2 + 0.34 I p + 1
In this study, a new equation is proposed in which the UBC of foundations on unsaturated silty soils is determined by adopting the total stress analysis philosophy presented above, with a bearing capacity fitting parameter (SΨ) based on the SS determined via the UCS tests and the SSD/MS value.
Various models have been proposed in the literature to estimate the UBC of unsaturated soils (see Table 1). Some of these proposed equations directly use the MS value, whereas the other group indirectly uses MS.

2. Materials and Methods

2.1. Material

Soil samples taken from the city of Adapazarı were used in the experimental studies to examine the change in the UBC of the shallow footings on unsaturated soils. The samples were taken from the Yenigün District of Adapazarı (Turkey), at a depth of 3–4 m. The properties of the silty soil sample used in this study according to ASTM D4318 [49] are given in Table 2. The soil sample was classified as low plasticity silt (ML) according to the USCS. Figure 3 shows the grain size distribution curve of the sample.
The mineralogical composition of the silt used in this study was determined with an X-ray diffraction analysis and is shown in Table 3. It indicates that elements such as calcium oxide and magnesium oxide, which are the primary cementing agents in the soil, are present in significant amounts in the soil sample [50,51]. However, studies in the literature have demonstrated that the cementing bonds that are disrupted in remolded samples do not re-form [50,52]. As a result, when compared to experiments carried out on in situ or undisturbed materials, the cohesiveness of the remolded samples is lower. Furthermore, research suggests that the shear resistance angle is less influenced than the cohesion value [53].

2.2. Method

In this study, the ultimate bearing capacity (UBC) of shallow foundations on unsaturated soils was investigated. The basic physical properties of silt samples taken from Adapazarı were determined and void ratios were selected for use in experiments. The natural void ratios of silts in Adapazarı were examined [54], and samples with void ratios of 0.65, 0.70, and 0.75 were used in the experiments. The sample SSDs were set at 65%, 70%, 75%, and 85% to account for seasonal groundwater level changes in Adapazarı. The shear strength angle and cohesion values of the silt samples were obtained by using direct shear tests.
The SS parameters of unsaturated soils can be measured using a modified MS-controlled triaxial apparatus or a direct shear box (DSB) test [53,55,56,57]. However, these methods can be costly and time-consuming, and the results are not as practical as those from the saturated state. A more widely accepted method is to combine the application of the targeted suction magnitude with a DSB test. Studies have shown that this method is consistent with the results obtained using a modified DSB test capable of MS control [53,58,59,60]. In this study, the shear strength of unsaturated Adapazarı silt was determined using a conventional direct shear test. The samples were prepared at the targeted SSD, and MS values were measured using a pressure plate and filter paper. The shear box test was carried out on a fully automatic direct shearing apparatus with a square shear box 6 × 6 cm in diameter and 2.5 cm in height. During the test, the samples were carefully isolated from air to maintain their saturation degree/suction values. The ∅b values of silt soil were calculated from the test results and MS values, and the UBC was determined using these values.
The relationship between the WC/SSD and MS is important in evaluating the behavior of unsaturated soils. In this study, the MS values of the samples were determined using the filter paper method and pressure plate method to create the SWCCs. The filter paper method, which was proposed in the 1930s, is an economical but slow method for measuring suction, and it can measure total and the MS values up to 30 MPa [61]. This method uses a filter paper whose calibration curve is known and places it in full contact with the sample to determine pore water flow. The measurement period is 6–8 days. After the moisture balance is achieved, the wet and dry weight of the filter paper is weighed on a balance with a sensitivity of 0.0001 g, and the corresponding MS value is found in the calibration curve according to the filter paper water content. The SWCC of the sample is formed by repeating these processes at different WCs from the saturated state to the air-dried state [28,62]. In this study, the MS values were determined with the filter paper method by using the calibration curve recommended for the Whatman No. 42 filter paper in ASTM 5298-92 [63].
The pressure plate method is used to apply suction using the axis translation technique [64]. Air pressure (ua) is applied to the samples placed on a ceramic with the high AEV in the steel cell coming from the inlet at the top of the cell, and pore water pressure (uw) is applied trough the inlet connected to the ceramic. This process must be continued until the water flow is balanced [28,65]. When the water at the output reaches equilibrium after the applied suction, the sample weight/volume is taken and the next suction stage is started. The MS (ua–uw) values were applied in incremental steps from 5 kPa to 1500 kPa. A 1500F1 pressure plate extractor with a 15-bar capacity was used to conduct the pressure plate experiments.
The UBC of foundations on unsaturated silt soils was examined by model tests. Previous research and experimental studies have shown that the applied loads will have no effect on the boundaries of the sample container if the soil model tank size is 6 or more times higher than the model foundation size [14,66,67]. For this reason, of the soil tank used in the current study was chosen to be greater than 6 times higher than the model foundation dimensions. The model test used a cylindrical model test box with a height of 240 mm and a diameter of 310 mm filled with the soil sample at the desired void ratio and soil saturation degree values. The foundation bearing capacity was investigated with the help of 50 mm diameter circle, 50 × 50 mm square, 42.3 mm circle, and 37.5 × 37.5 square foundation models placed on the model test box. The 42.3 mm circle and 37.5 × 37.5 mm square foundations were selected for further experiments as they have an equal base area.

Sample Preparation

The silty soil taken from the Adapazarı city center was first air-dried in the laboratory environment. The air-dried sample was pulverized by hand. In order to prepare the samples homogeneously at the desired water content, it was sieved through the No.10 (2 mm) sieve with for the maximum grain diameter, both to prevent lumping and to remove organic substances. The sieved soil sample was divided into groups of 2 kg, which were wetted by spraying deionized and deaired water for the desired degree of saturation was reached and mixed with the help of a sample preparation mixer. This process was repeated for each sample of different VR and SSD values. The prepared soil samples were placed in airtight containers and left at room temperature for 24 h for curing. With this procedure, a homogeneous soil-water mixture was obtained with no measurable difference between the desired WCs. After the standard 24 h curing period was completed, three different samples were taken from the different parts of each airtight container to check the WC and it was confirmed that the WCs of the mixtures in all the bags were equal within a ±0.5% evaporation/moisture change margin of error.
The prepared soil samples were compacted at a statically constant velocity in a model tank specifically designed for hydraulic press equipment. A metal plate with a diameter of 305 mm and a thickness of 30 mm was used as the clamping apparatus. While preparing the samples for the model experiments, they were statically compacted into two layers to obtain a homogeneous void ratio. By creating scratches between the layers, adherence losses that could occur between these layers were prevented. For each VR and SSD values, a prepared and cured soil sample equal to the calculated sample weights by using the volume-weight ratio of the soil was statically compacted in the model tank. After the UBC tests were carried out, two specimens were taken out from the compacted sample using 50 mm diameter stainless steel thin-wall tubes for the UC test. With the help of a small cylindrical sample mold that had a certain volume which was obtained from the model test mold, the weight and the WC measurements of the samples taken from different depths, as well as the VR and SSD were checked. In addition, the MS values were measured using the filter paper method on samples with a height of 20 mm and a diameter of 50 mm, which were taken from depths of 0.5B and 1.5B (Figure 4).
The samples for the DSB test were statically compacted, the same as those used in the model footing testing. The samples, prepared with the WC values corresponding to the desired MS values from the SWCC curves, were insulated from the air with silicone grease so that there was no loss in the WC during rapid shearing and no change in the MS value [53,58,68]. The shear rate applied in this study was determined to be 1.15 mm/min after considering other studies in the literature [12,14,53,60]. Experiments on the model load tests were run as displacement-controlled tests. According to earlier research on compacted samples, soil specimens can reach drained conditions when loaded at a strain rate between 0.0102 mm/min and 0.0132 mm/min [46,48]. In the current investigation, undrained loading conditions were simulated using a reasonably quick loading rate of 1.15 mm/min. The DSB tests were conducted in accordance with the ASTM D3080-98 [69] at normal stress levels of 59, 98, and 147 kPa. Due to the fast loading rate applied in the direct shear tests, the undrained shearing conditions were assumed to prevail. In order to confirm the assumption that there is no change in the gravimetric water content (GWC) value of the samples during the DSB test process, the sheared samples were subjected to MS and WC measurements directly after the test.

3. Results and Discussion

After the soil samples were created for the pressure plate tests and filter paper tests, they were statically compressed, as was carried out for the other tests, and the samples were taken with the help of metal rings with a diameter of 50 mm and a height of 20 mm. The samples were fixed by placing porous stones on the samples in order to reach the SSD and were kept in distilled water for 7 days. The samples taken from the model loading tests, on the other hand, were placed immediately on the filter paper to start the equilibrium stage and the MS values of the prepared samples were measured.
The SWCCs of the samples formed at three different void ratios were determined by the pressure plate and filter paper method. In the experimental study, model tests were conducted with soil samples compacted with targeted VRs (0.65, 0.7 and 0.75) and SSDs (i.e., 65%, 70%, 75%, 85%, 100%) considering seasonal groundwater level changes. To reflect this scenario, the samples were statically compressed with targeted VRs at four different SSDs. Since experiments were carried out on samples with three different VRs, the samples were prepared at these VRs for the SWCC experiments. Therefore, SWCC experiments were carried out on three samples (0.65, 0.7 and 0.75 void ratios) and SWCCs have been created according to the GWC. The most ideal curves of the experimental data were created with the Van Genuchten (1980) [70] model, which is one of the SWCC generation models available in the literature, for MS values ranges between 0 and 1,000,000 kPa (Figure 5). Since the SWCC data at high MS range could not be determined with the pressure plate (the suction was determined with the pressure plate up to 800 kPa), it was measured by the filter paper method, and it was again found to be compatible with the curves obtained from the Van Genuchten (1980) [70] model. The AEVs of the samples with 0.65, 0.70 and 0.75 void ratios have been determined as 12.4, 10.2 and 8.0 kPa, respectively.
Samples with VRs of 0.65, 0.70 and 0.75 and SSDs of 65%, 70%, 75%, 85% and 100% were created using static compression. The samples were saturated under water for 9 days. The SS were recorded as a function of horizontal displacement up to the maximum value. As seen in Figure 6, a clear peak is observed in the stress-strain graphs at each net stress (59, 98 and 147 kPa) at MS values higher than the AEV in the samples with 0.65 VR. No significant peak has been observed for the saturated state. A similar situation is observed for the samples with VRs of 0.70 and 0.75.
In each VR, the MS values taken from the SWCCs and the results of the shear box test performed at 65%, 70%, 75%, 85% and 100% saturation degrees were combined, and the MS—SS net normal stress (NNS) plots were drawn (Figure 7). The ∅b values calculated on these graphs are presented in Table 4. When Table 4 is examined, it is seen that lower ∅b values are calculated for the three different VRs at low NNS. The increase in the VR also increases the ∅b value.
Figure 8 shows the failure envelopes formed by considering the maximum SS values of the samples. Table 5 lists the SS parameters of the soils obtained from these failure envelopes. With the increase of the SSD, a decreasing trend is observed in the cohesion values and the SS angles of the samples with three different VRs. In the literature, it is a known behavior that a decrease in the SSD/increase in the MS value will cause an increase in the cohesion value [55]. In addition, the observation that the increase in the MS value causes an increase in the angle of SS is compatible with the data of Wen and Yan (2014) [53].
Figure 9 shows how the SS of silt soils tested at three different VRs varies with both the NNS and the SSD. The results show that the effect of the SSD on the SS decreases as the NNS value increases. In the tests carried out under NNSs of 59 and 98 kPa, there was a peak/trough fluctuation between the SSDs of 70% and 75% SSDs. This shows that in addition to the MS of the silty soil sample, a different void structure has the strongest or weakest effect on the SS at a certain SSD [53,60].
In the current work, model foundations experiments were conducted in a cylindrical tank filled with statically compacted soils to examine the UBC of foundations on unsaturated soils under undrained loading circumstances. The model foundations were loaded relatively quickly (1.15 mm/min) to avoid any changes to the suction value of the sample during the loading process. Square and circular shallow foundation models were loaded up to the peak failure conditions to determine the UBC. The dimensions of the glass fiber reinforced polyester tank used are 310 mm in diameter, height of 250 mm and a thickness of 10.2 mm. Model foundations with the largest foundation width of 50 mm were employed in the study. The dimensions of the model mold were selected large enough (>6D) that stresses on the boundaries of the mold due to the loads applied to the model foundation would have a negligible effect. It was confirmed by the control measurements carried out during the tests that no deformation occurred in the mold (The deformation was checked at three different measurement points on the outer surface of the mold.) during loading. Model foundation loadings were performed by using a triaxial loading frame. The vertical displacements of the model foundations were measured with the deformation gauges, and the loads were measured using a load cell (Figure 10). In both measurements, the data were recorded by taking their values at the predetermined deformations. Tests were terminated until the settlements reached 20 percent of the foundation width.
After the UBC tests were performed, two samples were taken from the compacted soils using 50 mm diameter stainless steel thin-walled pipes. A total of 96 UC test were performed on the samples taken. The average values of 12 different scenarios when classified with similar VRs and SSDs are shown in Table 6.
The model footing test results for both saturated and unsaturated silt sample prepared at the VR of 0.65 are shown in Figure 11. As seen, no clear failure point has been observed in the curves. Therefore, the UBC values have been evaluated by intersecting the tangents of the initial and the final linear part of the curves.
The state of the soil and punching shear failure after the model footing tests can be observed from Figure 12. In the punching failure described by Vesic (1973) [44], which is also valid in the current study:
  • A peak is not observed,
  • Except for where the load is applied, no soil heave is visible, and
  • It is defined that it is created by the vertical shear and compression of the soil immediately beneath the footing.
In such cases where the peak is not observed, the UBC of the foundation (qult) is determined in accordance with ASTM (D1194) [71]. The UBC is defined by ASTM (D1194) [71] as a stress value equal to one tenth (0.1B) of the foundation width. In addition, Steensen-Bach et al. (1987) [72] and Costa et al. (2003) [13] graphically determined the UBC by expanding the elastic and plastic parts of the loading curves profile. In Figure 11, the UBC values were calculated via both the graphical method (with the intersection point of the two linear sections) and the stress value corresponding to the 0.1B settlement value. With the use of the method valid in the literature, the UBC values corresponding to 0.1B have been taken into account in the next evaluations.
In this study, a total stress-based approach was employed. The most crucial part of the paper is introducing a new relationship that can estimate the UBC of foundations on unsaturated silty soils from the UC test and also estimate the UBC fitting parameter (SΨ) depending on the soil saturation (Equation (8)).
q u l t ( u n s a t ) = [ q u ( u n s a t ) 2 ] × [ 1 + 0.2 B L ] × N c s × S Ψ
where qult(unsat) is the UBC of the foundation on silty soil; qu(unsat) is the SS of unsaturated soil-based on UC; B is the width of the foundation; L is the length of the foundation; Ncs is the UBC; S is the degree of saturation; and Ψ is fitting parameter.
At the end of the experimental studies, the model tests performed on silty soil (72% silt content) showed that the UBC of the foundations was different from that of the foundations on sand or clay soils studied in the literature. As it is known, the behavior of silts is neither exactly similar to clays nor sands, and nor is it the average of the reactions of two neighboring soil types. Silt soils are not under fully undrained conditions as clay soils are, nor are they under drained conditions as sandy soils are. Therefore, a critical part of the unsaturated soil mechanics must be studied to better understand the characterization of the unsaturated silty soils. The results obtained were also plugged into the equations proposed by Oloo et al. (1997) [12] and Vanapalli and Muhammed (2007) [14] for the estimation of a foundation’s UBC of unsaturated soils and the results were compared.
Table 7 summarizes the measured the UBC values for all model foundations, including those estimated using the MTSA (i.e., Equations (3) and (8)), and those estimated using MESA (i.e., Equations (5) and (6)). The mean SΨ values, which were back calculated by using the Equation (8) suggested in this paper, have been found to be −2.89 and −1.33 when the UBC values were determined using 0.1B settlement and graphical methods, respectively. As can be seen from Table 6, although the difference between the calculated UBC values and the measured UBC values is small, the difference between the measured UBC values and the UBC values calculated with Equation (3) [i.e., that estimated using the value Nc(unsat) = 5.14 as suggested by Oh and Vanapalli (2013) [18] and the modifications of Skempton (1948) [2] is large.
Equation (6), which is one of the models that estimate the UBC using the MESA, estimated very high UBC values compared to both the graphical method and the UBC values corresponding to the 0.1B settlement. However, Equation (5), which calculates the UBC by using the SS parameters, ∅b values, and MS values, gives reliable results for the MS values equivalent to an SSD of 85%, 75% and 70%, according to the UBC values calculated with 0.1B method. In cases where the MS value is high, the model gives very high values according to the test results. The main reason for this is that the model proposed by Oloo et al. (1997) [12] takes into account the increase in SS after high MS values are reached and as the residual WC approaches saturation. It is seen that there are great differences between the UBC values estimated via Equation (5) and the UBC values calculated by using the graphical method on the model test data. In addition, there are significant differences between the UBC results obtained with the test data (and proposed with Equation (8)) and the method produced by Oloo et al., (1997) [12].
Figure 13 compares the estimated ultimate bearing capacity obtained with Equation (8) and the measured the ultimate bearing capacity obtained through the model footing tests. When these graphs are examined, it is seen that the UBC, which is sometimes measured with model tests and sometimes estimated using the proposed equation, is slightly higher than the estimate value, but it is understood that these differences are within a small margin of error. It is also understood that the UBC measured at an SSD of 70% and 75% is slightly higher than the estimated value. This situation is similar to the undulating behavior of the SS both mentioned above and presented in the literature [53]. Considering the contribution of the MS values to the SS, although the MS value of the sample with an SSD of 70% is lower than the MS value of the sample with an SSD of 60%, its contribution to the SS is higher. It also appears that the size of the model foundations (i.e., 50 mm × 50 mm square; 50 mm circle; 42.3 mm circle; and 37.5 mm × 37.5 mm square) rather than the foundation shape has a limited effect on the UBC under MS.
The variation in the UBC measured according to the MS values corresponding to the SSD of 65%, 70%, 75%, 85% and 100% at three different VRs with a 50 mm diameter circular model foundation is shown in Figure 14. The results show a significant increase in UBC due to the contribution of MS in the range of the MS values corresponding to the decreasing SSD. In addition, as the VR increases, the contribution of the MS to the UBC begins to be relatively low compared to the smaller MS values.

4. Conclusions

In this study, an equation was proposed to determine the UBC of shallow foundations on unsaturated silty soil layers. In an experimental model setup created for this purpose, the UBC values of different types and sizes of model footings on silty soil layers with a different SSD/MS and VR values were measured. In addition, the SWCCs and SS parameters of unsaturated silt were determined. The conclusions obtained as a result of these experimental studies and analyses can be listed as follows:
  • Although the SS parameters of the unsaturated silty soil sample changes depending on the MS and the VR values, the failure behavior (punching failure) remains the same.
  • An increase in cohesion values in accordance with the literature was observed due to the increase in MS for all silt samples with different VRs. However, an increase was observed in the SS angle value due to the MS magnitude.
  • It was observed in the literature that the values calculated with the equations for the UBC of shallow foundations on unsaturated soils do not comply with the results of the model tests carried out on silty soils. Within the scope of this study, a new equation that gives suitable results for shallow foundations on unsaturated silty soils is proposed (Equation (8)).
  • It was determined that the foundation’s UBC value for unsaturated silty soils can be estimated by using the unconfined compression test result and the fitting parameter depending on the SSD.
  • To evaluate foundations on unsaturated silty soils, the UBC can be estimated by considering the 0.1B method (ASSHTO method) by using the proposed equation in the current paper and by taking the fitting parameter (Ψ) as −2.89. If the graphical method is taken into account, the estimation can be made by taking the fitting parameter as −1.33 due to the generated relationship.
  • As the foundation size becomes smaller, the values of the foundation’s UBC values measured in the model tests and calculated from the proposed equation become closer to each other. In addition, it was observed that the model foundation dimensions, and the variation in the foundation type causes changes to the measured UBC value.
  • In future studies, UBC tests can be performed on silt soils with different plasticity indexes and a relationship can be derived between the plasticity index and the fitting parameter (Ψ).

Author Contributions

Writing—original draft, M.U.Y.; conceptualization, A.O.; supervision, A.O.; investigation, M.U.Y.; methodology, M.U.Y. and A.O.; data curation, M.U.Y. and A.O.; writing—review and editing, A.O. and M.U.Y. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

We thank Sedat Sert, Ertan Bol, and Kadir Kocaman (Sakarya University) for comments and suggestions.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Terzaghi, K. Theoretical Soil Mechanics; John Wiley & Sons, Inc.: New York, NY, USA, 1943. [Google Scholar]
  2. Skempton, A.W. The φ 0 Analysis of Stability and Its Theoretical Basis. In Proceedings of the 2nd International Conference on Soil Mechanics and Foundation Engineering (Rotterdam), Rotterdam, The Netherlands, 21–30 June 1948; pp. 72–77. [Google Scholar]
  3. Meyerhof, G.G. The Ultimate Bearing Capacity of Foudations. Geotechnique 1951, 2, 301–332. [Google Scholar] [CrossRef]
  4. Houston, S.L.; Houston, W.N.; Wagner, A.-M. Laboratory Filter Paper Suction Measurements. Geotech. Test. J. 1994, 17, 185–194. [Google Scholar]
  5. Guan, Y.; Fredlund, D.G. Use of the Tensile Strength of Water for the Direct Measurement of High Soil Suction. Can. Geotech. J. 1997, 34, 604–614. [Google Scholar] [CrossRef]
  6. Houston, S.L.; Perez-Garcia, N.; Houston, W.N. Shear Strength and Shear-Induced Volume Change Behavior of Unsaturated Soils from a Triaxial Test Program. J. Geotech. Geoenviron. Eng. 2008, 134, 1619–1632. [Google Scholar] [CrossRef] [Green Version]
  7. Bulut, R.; Wray, W.K. Free Energy of Water-Suction-in Filter Papers. Geotech. Test. J. 2005, 28, 355–364. [Google Scholar]
  8. Likos, W.J.; Lu, N. Hysteresis of Capillary Stress in Unsaturated Granular Soil. J. Eng. Mech. 2004, 130, 646–655. [Google Scholar] [CrossRef]
  9. Aldaood, A. Impact of Fine Materials on the Saturated and Unsaturated Behavior of Silty Sand Soil. Ain Shams Eng. J. 2020, 11, 717–725. [Google Scholar] [CrossRef]
  10. Zhang, C.; Chen, X.; Fan, W.; Zhao, J. A New Unified Failure Criterion for Unsaturated Soils. Environ. Earth Sci. 2015, 74, 3345–3356. [Google Scholar] [CrossRef]
  11. Yan, Q.; Zhao, J.; Zhang, C.; Wang, J. Ultimate Bearing Capacity of Strip Foundations in Unsaturated Soils Considering the Intermediate Principal Stress Effect. Adv. Civ. Eng. 2020, 2020, 8854552. [Google Scholar] [CrossRef]
  12. Oloo, S.Y.; Fredlund, D.G.; Gan, J.K. Bearing Capacity of Unpaved Roads. Can. Geotech. J. 1997, 34, 398–407. [Google Scholar] [CrossRef]
  13. Costa, Y.D.; Cintra, J.C.; Zornberg, J.G. Influence of Matric Suction on the Results of Plate Load Tests Performed on a Lateritic Soil Deposit. Geotech. Test. J. 2003, 26, 219–227. [Google Scholar]
  14. Vanapalli, S.K.; Mohamed, F.M. Bearing Capacity of Model Footings in Unsaturated Soils. In Experimental Unsaturated Soil Mechanics; Springer: Berlin/Heidelberg, Germany, 2007; pp. 483–493. [Google Scholar]
  15. Rojas, J.C.; Salinas, L.M.; Sejas, C. Plate-Load Tests on an Unsaturated Lean Clay. In Experimental Unsaturated Soil Mechanics; Springer: Berlin/Heidelberg, Germany, 2007; pp. 445–452. [Google Scholar]
  16. Zhang, F.; Bao, X.; Ikariya, T. A New Model for Unsaturated Soil Using Skeleton Stress and Degree of Saturation as State Variables. Soils Found. 2010, 50, 355–370. [Google Scholar] [CrossRef] [Green Version]
  17. Zhang, C.; Yan, Q.; Zhao, J.; Wang, J. Formulation of Ultimate Bearing Capacity for Strip Foundations Based on the Meyerhof Theory and Unsaturated Soil Mechanics. Comput. Geotech. 2020, 126, 103734. [Google Scholar] [CrossRef]
  18. Oh, W.T.; Vanapalli, S.K. Interpretation of the Bearing Capacity of Unsaturated Fine-Grained Soil Using the Modified Effective and the Modified Total Stress Approaches. Int. J. Geomech. 2013, 13, 769–778. [Google Scholar] [CrossRef]
  19. Ibrahim, K.M.H.I. Effect of Percentage of Low Plastic Fines on the Unsaturated Shear Strength of Compacted Gravel Soil. Ain Shams Eng. J. 2015, 6, 413–419. [Google Scholar] [CrossRef] [Green Version]
  20. Lotfizadeh, M.R.; Kamalian, M. Estimating Bearing Capacity of Strip Footings over Two-Layered Sandy Soils Using the Characteristic Lines Method. Int. J. Civ. Eng. 2016, 14, 107–116. [Google Scholar] [CrossRef]
  21. Maghvan, S.V.; Imam, R.; McCartney, J.S. Relative Density Effects on the Bearing Capacity of Unsaturated Sand. Soils Found. 2019, 59, 1280–1291. [Google Scholar] [CrossRef] [Green Version]
  22. Chen, T.; Xiao, S. An Upper Bound Solution to Undrained Bearing Capacity of Rigid Strip Footings Near Slopes. Int. J. Civ. Eng. 2020, 18, 475–485. [Google Scholar] [CrossRef]
  23. Chen, W.; Xia, W.; Zhang, S.; Wang, E. Study on the Influence of Groundwater Variation on the Bearing Capacity of Sandy Shallow Foundation. Appl. Sci. 2023, 13, 473. [Google Scholar] [CrossRef]
  24. Silveira, I.A.; Rodrigues, R.A. Collapsible Behavior of Lateritic Soil Due to Compacting Conditions. Int. J. Civ. Eng. 2020, 18, 1157–1166. [Google Scholar] [CrossRef]
  25. Liu, Y.; Vanapalli, S.K. Mechanical Behavior of a Floating Model Pile in Unsaturated Expansive Soil Associated with Water Infiltration: Laboratory Investigations and Numerical Simulations. Soils Found. 2021, 61, 929–943. [Google Scholar] [CrossRef]
  26. Tan, M.; Cheng, X.; Vanapalli, S. Simple Approaches for the Design of Shallow and Deep Foundations for Unsaturated Soils I: Theoretical and Experimental Studies. Indian Geotech. J. 2021, 51, 97–114. [Google Scholar] [CrossRef]
  27. Tan, M.; Vanapalli, S.K. Foundation Bearing Capacity Estimation on Unsaturated Soil Slope under Transient Flow Condition Using Slip Line Method. Comput. Geotech. 2022, 148, 104804. [Google Scholar] [CrossRef]
  28. Vanapalli, S.K.; Salinas, L.M.; Avila, D.; Karube, D. Suction and Storage Characteristics of Unsaturated Soils. In Unsaturated Soils-Volume 3: Proceedings of the 3rd International Conference on Unsaturated Soils, UNSAT 2002, 10–13 March 2002, Recife, Brazil; CRC Press: Boca Raton, FL, USA, 2021; p. 1045. [Google Scholar]
  29. Cheng, Y.-Y.; Gao, X.-G.; Liu, T.-H.; Li, L.-X.; Du, W.; Hamad, A.; Wang, J.-P. Effect of Water Content on Strength of Alluvial Silt in The Lower Yellow River. Water 2022, 14, 3231. [Google Scholar] [CrossRef]
  30. Fredlund, D.G.; Morgenstern, N.R. Stress State Variables for Unsaturated Soils. J. Geotech. Eng. Div. 1977, 103, 447–466. [Google Scholar] [CrossRef]
  31. Oh, W.T.; Vanapalli, S.K. Modelling the Applied Vertical Stress and Settlement Relationship of Shallow Foundations in Saturated and Unsaturated Sands. Can. Geotech. J. 2011, 48, 425–438. [Google Scholar] [CrossRef] [Green Version]
  32. Vahedifard, F.; Robinson, J.D. Unified Method for Estimating the Ultimate Bearing Capacity of Shallow Foundations in Variably Saturated Soils under Steady Flow. J. Geotech. Geoenviron. Eng. 2016, 142, 04015095. [Google Scholar] [CrossRef]
  33. Vo, T.; Russell, A.R. Bearing Capacity of Strip Footings on Unsaturated Soils by the Slip Line Theory. Comput. Geotech. 2016, 74, 122–131. [Google Scholar] [CrossRef] [Green Version]
  34. Oh, W.T.; Vanapalli, S.K. Modeling the Stress versus Settlement Behavior of Shallow Foundations in Unsaturated Cohesive Soils Extending the Modified Total Stress Approach. Soils Found. 2018, 58, 382–397. [Google Scholar] [CrossRef]
  35. Ghasemzadeh, H.; Akbari, F. Determining the Bearing Capacity Factor Due to Nonlinear Matric Suction Distribution in the Soil. Can. J. Soil Sci. 2019, 99, 434–446. [Google Scholar] [CrossRef]
  36. Ghasemzadeh, H.; Akbari, F. Investigation of Soil Active Wedge Angle with Linear Matric Suction Distribution below the Footing. Int. J. Civ. Eng. 2020, 18, 161–168. [Google Scholar] [CrossRef]
  37. Akbari Garakani, A.; Sadeghi, H.; Saheb, S.; Lamei, A. Bearing Capacity of Shallow Foundations on Unsaturated Soils: Analytical Approach with 3D Numerical Simulations and Experimental Validations. Int. J. Geomech. 2020, 20, 04019181. [Google Scholar] [CrossRef]
  38. Lu, N.; Godt, J.W.; Wu, D.T. A Closed-Form Equation for Effective Stress in Unsaturated Soil. Water Resour. Res. 2010, 46, W05515. [Google Scholar] [CrossRef] [Green Version]
  39. Griffiths, D.V.; Lu, N. Unsaturated Slope Stability Analysis with Steady Infiltration or Evaporation Using Elasto-Plastic Finite Elements. Int. J. Numer. Anal. Methods Geomech. 2005, 29, 249–267. [Google Scholar] [CrossRef]
  40. Zhang, L.L.; Fredlund, D.G.; Fredlund, M.D.; Wilson, G.W. Modeling the Unsaturated Soil Zone in Slope Stability Analysis. Can. Geotech. J. 2014, 51, 1384–1398. [Google Scholar] [CrossRef]
  41. Consoli, N.C.; Schnaid, F.; Milititsky, J. Interpretation of Plate Load Tests on Residual Soil Site. J. Geotech. Geoenviron. Eng. 1998, 124, 857–867. [Google Scholar] [CrossRef]
  42. Tang, Y.; Taiebat, H.A.; Russell, A.R. Bearing Capacity of Shallow Foundations in Unsaturated Soil Considering Hydraulic Hysteresis and Three Drainage Conditions. Int. J. Geomech. 2017, 17, 04016142. [Google Scholar] [CrossRef]
  43. Meyerhof, G.G. Some Recent Research on the Bearing Capacity of Foundations. Can. Geotech. J. 1963, 1, 16–26. [Google Scholar] [CrossRef]
  44. Vesić, A.S. Analysis of Ultimate Loads of Shallow Foundations. J. Soil Mech. Found. Div. 1973, 99, 45–73. [Google Scholar] [CrossRef]
  45. Kumbhojkar, A.S. Numerical Evaluation of Terzaghi’s N γ. J. Geotech. Eng. 1993, 119, 598–607. [Google Scholar] [CrossRef]
  46. Gan, J.K.M.; Fredlund, D.G.; Rahardjo, H. Determination of the Shear Strength Parameters of an Unsaturated Soil Using the Direct Shear Test. Can. Geotech. J. 1988, 25, 500–510. [Google Scholar] [CrossRef]
  47. Escario, V.; Saez, J. The Shear Strength of Partly Saturated Soils. Geotechnique 1986, 36, 453–456. [Google Scholar] [CrossRef]
  48. Vanapalli, S.K.; Fredlund, D.G.; Pufahl, D.E. The Relationship between the Soil-Water Characteristic Curve and the Unsaturated Shear Strength of a Compacted Glacial Till. Geotech. Test. J. 1996, 19, 259–268. [Google Scholar]
  49. ASTM D4318-17e1; Standard Test Methods for Liquid Limit, Plastic Limit, and Plasticity Index of Soils. ASTM International: West Conshohocken, PA, USA, 2010.
  50. Kruse, G.A.; Dijkstra, T.A.; Schokking, F. Effects of Soil Structure on Soil Behaviour: Illustrated with Loess, Glacially Loaded Clay and Simulated Flaser Bedding Examples. Eng. Geol. 2007, 91, 34–45. [Google Scholar] [CrossRef]
  51. Ltifi, M.; Abichou, T.; Tisot, J.P. Effects of Soil Aging on Mechanical and Hydraulic Properties of a Silty Soil. Geotech. Geol. Eng. 2014, 32, 1101–1108. [Google Scholar] [CrossRef]
  52. Dijkstra, T.A.; Rogers, C.D.F.; Smalley, I.J.; Derbyshire, E.; Li, Y.J.; Meng, X.M. The Loess of North-Central China: Geotechnical Properties and Their Relation to Slope Stability. Eng. Geol. 1994, 36, 153–171. [Google Scholar] [CrossRef]
  53. Wen, B.-P.; Yan, Y.-J. Influence of Structure on Shear Characteristics of the Unsaturated Loess in Lanzhou, China. Eng. Geol. 2014, 168, 46–58. [Google Scholar] [CrossRef]
  54. Önalp, A.; Arel, E.; Bol, E.; Özocak, A.; Sert, S. The Assessment of Liquefaction Potential with Dissipation Method in Piezocone Penetration Testing (CPTU); Scientific and Technological Research Council of Turkey: Ankara, Türkiye, 2007. [Google Scholar]
  55. Fredlund, D.G.; Rahardjo, H. Soil Mechanics for Unsaturated Soils; John Wiley & Sons: Hoboken, NJ, USA, 1993. [Google Scholar]
  56. Hu, Z.Q.; Shen, Z.J.; Xie, D.Y. Research on Structural Behavior of Unsaturated Loess. Chin. J. Rock Mech. Eng. 2000, 19, 775–779. [Google Scholar]
  57. Maleki, M.; Bayat, M. Experimental Evaluation of Mechanical Behavior of Unsaturated Silty Sand under Constant Water Content Condition. Eng. Geol. 2012, 141, 45–56. [Google Scholar] [CrossRef]
  58. Oloo, S.Y.; Fredlund, D.G. A Method for Determination of φ b for Statically Compacted Soils. Can. Geotech. J. 1996, 33, 272–280. [Google Scholar] [CrossRef]
  59. Vanapalli, S.K.; Fredlund, D.G. Comparison of Different Procedures to Predict Unsaturated Soil Shear Strength. Geotech. Spec. Publ. 2000, 99, 195–209. [Google Scholar]
  60. Vanapalli, S.K.; Lane, J.J. A Simple Technique for Determining the Shear Strength of Finegrained Unsaturated Soils Using the Conventional Direct Shear Apparatus. In Proceedings of the Second Canadian Specialty Conference on Computer Applications in Geotechnique, Winnipeg, Canada; Citeseer. 2002; pp. 245–253. [Google Scholar]
  61. Gardner, R. A Method of Measuring the Capillary Tension of Soil Moisture over a Wide Moisture Range. Soil Sci. 1937, 43, 277–284. [Google Scholar] [CrossRef]
  62. Qian, J.S.; Lu, H. Effect of Compaction Degree on Soil-Water Characteristic Curve of Chongming Clay. In Applied Mechanics and Materials; Trans Tech Publications Ltd.: Wollerau, Switzerland, 2011; Volume 90, pp. 701–706. [Google Scholar]
  63. ASTM D5298-16; Standard Test Method for Measurement of Soil Potential (Suction) Using Filter Paper. ASTM International: West Conshohocken, PA, USA, 2016.
  64. Hilf, J.W. An Investigation of Pore-Water Pressure in Compacted Cohesive Soils; University of Colorado at Boulder: Boulder, CO, USA, 1956. [Google Scholar]
  65. Cresswell, H.P.; Green, T.W.; McKenzie, N.J. The Adequacy of Pressure Plate Apparatus for Determining Soil Water Retention. Soil Sci. Soc. Am. J. 2008, 72, 41–49. [Google Scholar] [CrossRef]
  66. Adams, M.T.; Collin, J.G. Large Model Spread Footing Load Tests on Geosynthetic Reinforced Soil Foundations. J. Geotech. Geoenviron. Eng. 1997, 123, 66–72. [Google Scholar] [CrossRef]
  67. Oh, W.T.; Garga, V.K.; Vanapalli, S.K. Shear Strength Characteristics of Statically Compacted Unsaturated Kaolin. Can. Geotech. J. 2008, 45, 910–922. [Google Scholar] [CrossRef]
  68. Oloo, S.Y. A Bearing Capacity Approach to the Design of Low-Volume Traffic Roads; University of Saskatchewan: Saskatoon, SK, Canada, 1999. [Google Scholar]
  69. ASTM D3080-04; Standard Test Method for Direct Shear Test of Soils under Consolidated Drained Conditions. ASTM International: West Conshohocken, PA, USA, 1999.
  70. Van Genuchten, M.T. A Closed-Form Equation for Predicting the Hydraulic Conductivity of Unsaturated Soils. Soil Sci. Soc. Am. J. 1980, 44, 892–898. [Google Scholar] [CrossRef] [Green Version]
  71. ASTM D1194-94; Standard Test Method for Bearing Capacity of Soil for Static Load and Spread Footings. ASTM International: West Conshohocken, PA, USA, 2003.
  72. Steensen-Bach, J.O.; Foged, N.; Steenfelt, J.S. Capillary Induced Stresses―fact or Fiction? In Proceedings of the 9th European Conference on Soil Mechanics and foundation Engineering, Dublin, Ireland, 31 August–3 September 1987; pp. 83–89. [Google Scholar]
Figure 1. The effect of MS value on SS [46].
Figure 1. The effect of MS value on SS [46].
Applsci 13 01308 g001
Figure 2. The relationship between Ψ and Ip [14].
Figure 2. The relationship between Ψ and Ip [14].
Applsci 13 01308 g002
Figure 3. Grain-size distribution of samples used in the study.
Figure 3. Grain-size distribution of samples used in the study.
Applsci 13 01308 g003
Figure 4. Schema showing the procedure used to determine the MC under the foundation.
Figure 4. Schema showing the procedure used to determine the MC under the foundation.
Applsci 13 01308 g004
Figure 5. SWCCs of silty soil prepared at different VRs.
Figure 5. SWCCs of silty soil prepared at different VRs.
Applsci 13 01308 g005
Figure 6. Shear strain curves for silt sample with VR = 0.65 (from shear box tests): (a) SSD = 65%; (b) SSD = 70%; (c) SSD = 75%; (d) SSD = 85%; (e) SSD = 100%.
Figure 6. Shear strain curves for silt sample with VR = 0.65 (from shear box tests): (a) SSD = 65%; (b) SSD = 70%; (c) SSD = 75%; (d) SSD = 85%; (e) SSD = 100%.
Applsci 13 01308 g006
Figure 7. MS-NNS-SS variation for void ratios: (a) VR = 0.65; (b) VR = 0.70; (c) VR = 0.75.
Figure 7. MS-NNS-SS variation for void ratios: (a) VR = 0.65; (b) VR = 0.70; (c) VR = 0.75.
Applsci 13 01308 g007
Figure 8. SS-SSD relations under different VR and NNS: (a) VR = 0.65; (b) VR = 0.70; (c) VR = 0.75.
Figure 8. SS-SSD relations under different VR and NNS: (a) VR = 0.65; (b) VR = 0.70; (c) VR = 0.75.
Applsci 13 01308 g008
Figure 9. Saturation-shear stress relationships: (a) VR = 0.65; (c) VR = 0.70; (e) VR = 0.75, Saturation-% shear stress increase relationships: (b) VR = 0.65; (d) VR = 0.70; (f) VR = 0.75.
Figure 9. Saturation-shear stress relationships: (a) VR = 0.65; (c) VR = 0.70; (e) VR = 0.75, Saturation-% shear stress increase relationships: (b) VR = 0.65; (d) VR = 0.70; (f) VR = 0.75.
Applsci 13 01308 g009
Figure 10. Model test setup: (a) schematic; (b) experimental picture.
Figure 10. Model test setup: (a) schematic; (b) experimental picture.
Applsci 13 01308 g010
Figure 11. UBC model test results (VR = 0.65 and 50 mm circular model foundation).
Figure 11. UBC model test results (VR = 0.65 and 50 mm circular model foundation).
Applsci 13 01308 g011
Figure 12. Soil settlement after loading test and cracks around model foundation: (a) 50 mm × 50 mm square; (b) 50 mm circle.
Figure 12. Soil settlement after loading test and cracks around model foundation: (a) 50 mm × 50 mm square; (b) 50 mm circle.
Applsci 13 01308 g012
Figure 13. Comparison of the bearing capacity values found using the proposed Equation (8) and those found using the 0.1B technique: (a) 50 mm × 50 mm square; (b) 50 mm circle; (c) 42.3 mm circle; (d) 37.5 mm × 37.5 mm square.
Figure 13. Comparison of the bearing capacity values found using the proposed Equation (8) and those found using the 0.1B technique: (a) 50 mm × 50 mm square; (b) 50 mm circle; (c) 42.3 mm circle; (d) 37.5 mm × 37.5 mm square.
Applsci 13 01308 g013
Figure 14. Graphs of 50 mm circle UBC: (a) MS (kPa); (b) SSD %.
Figure 14. Graphs of 50 mm circle UBC: (a) MS (kPa); (b) SSD %.
Applsci 13 01308 g014
Table 1. Bearing capacity models for unsaturated soil.
Table 1. Bearing capacity models for unsaturated soil.
AuthorsUBC EquationSoil Type
Oloo et al. (1997) [12] q u l t = { c + ( u a u w ) b t a n + [ ( u a u w ) ( u a u w ) b ] t a n b } N c + 1 2 B γ N γ -
Vanapalli & Mohamed (2007) [14] q u l t = { [ c + ( u a u w ) b t a n S Ψ t a n ] + ( u a u w ) A V E S Ψ t a n } N c ξ c + 1 2 B γ N γ ξ γ Poorly graded sand
Oh & Vanapalli (2013) [18] q u l t ( u n s a t ) = [ q u ( u n s a t ) 2 ] × [ 1 + 0.2 B L ] × N u n s a t Low plasticity clay
Vahedifard & Robinson (2016) [32] S e = ( 1 1 + { l n ( 1 + q k s ) e γ w α z q k s } n ) ( n 1 ) n -
Tang et al. (2017) [42] q u l t = [ c + ( χ s ) A V E t a n ] N c d c + q u l t q N q d q + 0.5 γ B N γ d γ -
Garakani et al. (2020) [37] q u l t = [ c + c A V E ] N c ξ c + q N q ξ q + 0.5 B γ N γ + s ( N s ) c s t t a n b ξ s Poorly graded sand
Zhang et al. (2020) [17] q u l t = [ c + ( u a u w ) m t a n b ] N c M + σ 0 N q M 1 2 ( B γ u a ) N γ N γ M Sand
Table 2. Physical properties of the soil used in the experimental study.
Table 2. Physical properties of the soil used in the experimental study.
PropertyValueSymbol and Unit
No 200#89FC (%)
Liquid limit35.8LL (%)
Plastic limit25.2PL (%)
Plasticity index10.6IP (%)
Specific gravity2.692Gs
Clay ratio17C (%)
Silt ratio72M (%)
Sand ratio11S (%)
Soil class: Low Plasticity Silt (ML)
Table 3. Mineralogical properties of the soil sample.
Table 3. Mineralogical properties of the soil sample.
SymbolElementValue (%)
SiO2Silicon dioxide40.94
Al2O3Alumina11.09
Fe2O3Iron oxide5.36
MgOMagnesium oxide4.48
CaOQuicklime15.58
K2OPotassium oxide1.72
Na2OSodium oxide2.09
TiO2Titanium oxide0.82
-Other17.92
Table 4. Angles showing the slope of the SS increase with respect to the MS.
Table 4. Angles showing the slope of the SS increase with respect to the MS.
e( σ n u a ) kPa b a v e r a g e b
0.65594.66.5
987.6
1477.2
0.70595.77.3
987.1
1479.0
0.75595.68.1
988.8
14710.0
Table 5. SS parameters of samples with different SSD.
Table 5. SS parameters of samples with different SSD.
eSS ParametersSSD, %
10085757065
0.65c5.529.132.938.845.1
27.427.828.330.831.5
0.70c7.131.739.138.945.9
24.222.623.826.927.6
0.75c9.630.935.136.841.5
21.117.818.822.423.5
Table 6. Angles showing the slope of the SS increase with respect to the MS.
Table 6. Angles showing the slope of the SS increase with respect to the MS.
SSD, %VR = 0.65VR = 0.70VR = 0.75
qu (kPa)qu (kPa)qu (kPa)
65116.0571.8854.31
7094.6865.1937.99
7575.5858.8931.23
8568.236.5729.31
Table 7. Model test results and estimated bearing capacity values.
Table 7. Model test results and estimated bearing capacity values.
Model FootingVRSSD
%
WC
%
MS
kPa
Oloo et al., 1997 (Equation (5))Vanapalli & Muhammed 2007 (Equation (6))Oh & Vanapalli 2013 (Equation (3))0.1B
Settlement
Method
(Exp)
Grap. Method (Exp.)UBC (Equation (8))Ψ
0.1B Method
Ψ
Grap. Method
50 mm Circle0.65164.215.69284.113001501348899648826−2.89−1.33
0.64770.116.90165.969391318292762550597
0.64874.418.0091.907121121233658470415
0.65683.820.4121.54497767210445300291
0.69664.316.70229.09983934222588385526−2.89−1.33
0.69968.617.80141.25752857201499345411
0.70174.519.4063.10547679182372280323
0.70283.221.7015.61423521113213140156
0.74964.717.99157.28645587167424320397−2.89−1.33
0.7570.519.6782.54484522117346210240
0.75675.521.1928.1836742696255180171
0.7584.423.5114.0233641390187110125
50 mm × 50 mm Square0.65264.815.70284.0112941255348905625826−2.89−1.33
0.65069.416.80174.169581136292773560597
0.65573.918.0091.90706946233595410415
0.64784.120.2223.99498567210425290291
0.69963.716.60241.731016890222548375526−2.89−1.33
0.70168.417.80141.25752812201503355411
0.70675.219.7056.67531663182360250323
0.70683.621.9013.28417485113210160156
0.75164.718.05149.05620538167398305397−2.89−1.33
0.74970.419.6382.54477502117327215240
0.74874.421.1928.1836044096250165171
0.75182.623.0418.3833841090187112125
42.3 mm Circle0.65164.915.70284.0112941255348946630826−2.89−1.33
0.65169.316.70157.289061076292749500597
0.64474.918.1087.10692922233486345415
0.65283.120.0928.18511699210406245291
0.69864.016.70229.09983870222561365526−2.89−1.33
0.69369.417.90133.86733795201494345411
0.69873.919.2070.25566703182347200323
0.70684.122.1011.93413478113201120156
0.75464.718.13141.25604530167444335397−2.89−1.33
0.75170.719.6882.54477502117367220240
0.74873.820.8450.8940948096252160171
0.74984.723.6012.5932639290176105125
37.5 mm × 37.5 mm Square0.64464.915.72279.4612851244348887570826−2.89−1.33
0.65768.216.50194.9810261211292778510597
0.64874.317.9092.29712948233460330415
0.66584.420.2323.99503664210335225291
0.70163.616.60241.731014890222519360526−2.89−1.33
0.69968.517.90133.86731796201460320411
0.69974.319.3068.25559697182314180323
0.70384.622.1011.93412534113184100156
0.74763.817.70165.96655554167477345397−2.89−1.33
0.75370.619.5882.54475502117335210240
0.74774.020.5356.6741949196253155171
0.76984.724.489.1231740890161108125
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Yilmazoglu, M.U.; Ozocak, A. Bearing Capacity of Shallow Foundations on Unsaturated Silty Soils. Appl. Sci. 2023, 13, 1308. https://doi.org/10.3390/app13031308

AMA Style

Yilmazoglu MU, Ozocak A. Bearing Capacity of Shallow Foundations on Unsaturated Silty Soils. Applied Sciences. 2023; 13(3):1308. https://doi.org/10.3390/app13031308

Chicago/Turabian Style

Yilmazoglu, Mehmet Ugur, and Askin Ozocak. 2023. "Bearing Capacity of Shallow Foundations on Unsaturated Silty Soils" Applied Sciences 13, no. 3: 1308. https://doi.org/10.3390/app13031308

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop