Next Article in Journal
Congenital Haemostasis Disorders and Urology Surgery: Is It Safe?
Next Article in Special Issue
Reply to Rubin, J.M.; Kripfgans, O.D. Comment on “Barbieri et al. Umbilical Vein Blood Flow in Uncomplicated Pregnancies: Systematic Review of Available Reference Charts and Comparison with a New Cohort. J. Clin. Med. 2023, 12, 3132”
Previous Article in Journal
Are There Sex-Related Differences in the Effectiveness of Janus Kinase Inhibitors in Rheumatoid Arthritis Patients?
Previous Article in Special Issue
Clinical Ultrasound Applications in Obstetrics and Gynecology in the Year 2024
 
 
Reply published on 30 April 2024, see J. Clin. Med. 2024, 13(9), 2654.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Comment

Comment on Barbieri et al. Umbilical Vein Blood Flow in Uncomplicated Pregnancies: Systematic Review of Available Reference Charts and Comparison with a New Cohort. J. Clin. Med. 2023, 12, 3132

by
Jonathan M. Rubin
* and
Oliver D. Kripfgans
Department of Radiology, University of Michigan, Ann Arbor, MI 48109-2026, USA
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2024, 13(8), 2347; https://doi.org/10.3390/jcm13082347
Submission received: 13 March 2024 / Revised: 2 April 2024 / Accepted: 15 April 2024 / Published: 18 April 2024
(This article belongs to the Special Issue Clinical Imaging Applications in Obstetrics and Gynecology)
We would like to comment on the systemic review article published in the Journal of Clinical Medicine by Barbieri et al. Umbilical vein blood flow in uncomplicated pregnancies: systematic review of available reference charts and comparison with a new cohort [1].
We have been following the authors’ efforts in promoting the use of blood volume flow for assessing fetal well-being for over 20 years [2,3]. We agree that these authors have presented many reasons justifying the use of true umbilical cord volume flow estimates for fetal assessment [1,4]. In fact, it is very odd, that surrogate flow measures such as blood flow velocities or indices, such as systolic/diastolic ratios, are employed at all when true flow estimates are and have been available on most ultrasound machines for over four decades. However, as the authors point out, volume flow estimates are generally only employed in research settings [1]. This is despite the fact the ultrasound equipment and images have steadily improved with time. One must conclude that it is likely that there are systematic problems with the methodology that are at fault. Either the techniques Barbieri et al. [1] use fail because of incorrect assumptions and/or the measurements themselves are too cumbersome to perform or to inaccurate to be clinically useful. We believe that both are the case.
The method presented by Barbieri et al. [1] where volume flow in the umbilical vein (UV-Q) = mean velocity times (½ diameter)2, is calculated from b-mode images of the vessel and 1D sampling of the velocity using spectral Doppler. The estimates rely on several critical assumptions that in general are rarely if ever valid [5,6]. First, they assume that the flow in the umbilical vein is laminar and cylindrically symmetric. Given the spiral geometry of the vessels in the umbilical cord, this is almost never the case. In fact, the flow must be asymmetric with the higher velocities along the greater curvature of the vein [7]. Therefore, sampling for mean velocity estimates will vary depending on how the sample volume is positioned through the center of the vessel which is also consistent with the authors’ statement that volume flow estimates vary depending on the sampling site in the cord. Physically, this cannot be the case; since blood flow in the cord must be the same throughout its entire length since there are no sources or sinks that alter the flow [8]. More precise measurements in the free-floating cord than in the fetal abdomen must reflect systematic differences in the flow profiles or in the definitions of the vessel walls between the two sites. Further, assuming a Reynolds number for blood flow in the umbilical vein of about 350, even if the cord “looks straight”, a cylindrically symmetric profile will not have developed within the apparent straight segment due to prior turbulence or tortuosity [9]. Next, these estimates require angle correction, which is another source of error and an annoyance. Interestingly, some sampling methods suggest that scanning directly along the path of the vessel, which corresponds to a Doppler angle of zero degrees, can overcome this problem [10]. Typically, investigators then use ½ the peak velocity to represent the mean. This estimate again relies on the flow being laminar and cylindrically symmetric, which as pointed out, is rarely ever true [11]. Finally, vessel cross-sectional estimates are typically made using linear estimates of the vein diameter on b-mode images. This measurement assumes that the venous cross-section is a circle, a major assumption. Also, the measurement error is compounded by the fact that diameter is being used as a means of estimating cross-sectional area. Even if the cross-section is a circle, the relative error in the area estimate is twice the relative error in the diameter. So, for example, if an umbilical vein measures 4 mm in diameter, and the error is ±1 mm, the area estimate will have an error of ±50%. Lastly, the authors propose measuring the venous diameter from the back of the echo from the near wall to the front of the echo from the far wall. This measurement will be highly dependent on the transducer frequency and axial point-spread function. A better, less equipment dependent measure would be from the front of the front wall reflection to the front of the backwall reflection. All the sources of error mentioned above are systematic. Different methods of random error analysis such as z-scores will not solve these problems.
Because of these issues, we have been using flux estimates across blood vessels using Gauss’s divergence theorem to estimate volume flow [12,13,14,15]. This method has many advantages including angle independence, flow profile independence, and vessel geometry independence. Annoying measurements such as angle correction and diameter estimates are not required. The measurement process could be easy to perform and nearly automatic. We have shown about a 2.5 times improvement in precision of umbilical vein flow measurements using this method over the spectral Doppler technique the authors use [15]. The method uses standard color and power flow ultrasound with one additional requirement; it must be done in 3D. A standard 3D mechanical probe used for making baby faces will work. Using a 2D array probe, literally dozens of estimates can be obtained in a few seconds, making mean flow measurements statistically very robust.
The biggest obstacle to general clinical implementation of this method is that unlike standard spectral Doppler, it has not been implemented on any clinical ultrasound machines. This is unfortunate since any ultrasound machine that can carry out 3D imaging along with color flow and color power imaging can implement this new method. We would hope that these authors, along with other practitioners interested in estimating umbilical venous volume flow, would encourage ultrasound companies to incorporate this method on their machines. Hopefully, we will see a new leap in the levels of fetal assessment initiated by measuring true blood flow in the umbilical cord.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Barbieri, M.; Zamagni, G.; Fantasia, I.; Monasta, L.; Lo Bello, L.; Quadrifoglio, M.; Ricci, G.; Maso, G.; Piccoli, M.; Di Martino, D.D.; et al. Umbilical Vein Blood Flow in Uncomplicated Pregnancies: Systematic Review of Available Reference Charts and Comparison with a New Cohort. J. Clin. Med. 2023, 12, 3132. [Google Scholar] [CrossRef] [PubMed]
  2. Ferrazzi, E. Measurement of venous blood flow in the human fetus: A dream comes true, but now for some standardization. Ultrasound Obstet. Gynecol. 2001, 18, 1–4. [Google Scholar] [CrossRef] [PubMed]
  3. Ferrazzi, E.; Rigano, S.; Bozzo, M.; Giovannini, N.; Galan, H.; Battaglia, F.C. Umbilical vein blood flow in growth-restricted fetuses. Ultrasound Obstet. Gynecol. 2000, 16, 432–438. [Google Scholar] [CrossRef] [PubMed]
  4. Stampalija, T.; Gyte, G.M.; Alfirevic, Z. Utero-placental Doppler ultrasound for improving pregnancy outcome. Cochrane Database Syst. Rev. 2010, 2010, CD008363. [Google Scholar] [CrossRef] [PubMed]
  5. Burns, P.N. Measuring volume flow with Doppler ultrasound-an old nut. Ultrasound Obstet. Gynecol. 1992, 2, 238–241. [Google Scholar] [CrossRef] [PubMed]
  6. Gill, R. Measurement of blood flow by ultrasound: Accuracy and sources of error. Ultrasound Med. Biol. 1985, 11, 625–641. [Google Scholar] [CrossRef] [PubMed]
  7. Verkaik, A.C.; Beulen, B.W.A.M.M.; Bogaerds, A.C.B.; Rutten, M.C.M.; van de Vosse, F.N. Estimation of volume flow in curved tubes based on analytical and computational analysis of axial velocity profiles. Phys. Fluids 2009, 21, 023602. [Google Scholar] [CrossRef]
  8. Davies, J.E.; Walker, J.T.; Keating, A. Concise review: Wharton’s Jelly: The rich, but enigmatic, source of mesenchymal stromal Cells. Stem Cells Transl. Med. 2017, 6, 1620–1630. [Google Scholar] [CrossRef] [PubMed]
  9. Lew, H.S.; Fung, Y.C. Entry flow into blood vessels at arbitrary Reynolds number. J. Biomech. 1970, 3, 23–38. [Google Scholar] [CrossRef] [PubMed]
  10. Najafzadeh, A.; Dickinson, J.E. Umbilical venous blood flow and its measurement in the human fetus. J. Clin. Ultrasound 2012, 40, 502–511. [Google Scholar] [CrossRef] [PubMed]
  11. Krams, R.; Bambi, G.; Guidi, F.; Helderman, F.; van der Steen, A.F.; Tortoli, P. Effect of vessel curvature on Doppler derived velocity profiles and fluid flow. Ultrasound Med. Biol. 2005, 31, 663–671. [Google Scholar] [CrossRef] [PubMed]
  12. Kripfgans, O.D.; Rubin, J.M.; Hall, A.L.; Gordon, M.B.; Fowlkes, J.B. Measurement of volumetric flow. J. Ultrasound Med. 2006, 25, 1305–1311. [Google Scholar] [CrossRef] [PubMed]
  13. Lui, G.Y.; Burns, P.N. The attenuation compensated C-mode flowmeter: A new Doppler method for blood volume flow measurement. In Proceedings of the 1997 IEEE Ultrasonics Symposium Proceedings, Toronto, ON, Canada, 5–8 October 1997; Volume 2, pp. 1285–1289. [Google Scholar]
  14. Pinter, S.Z.; Rubin, J.M.; Kripfgans, O.D.; Treadwell, M.C.; Romero, V.C.; Richards, M.S.; Zhang, M.; Hall, A.L.; Fowlkes, J.B. Three-dimensional sonographic measurement of blood volume flow in the umbilical cord. J. Ultrasound Med. 2012, 31, 1927–1934. [Google Scholar] [CrossRef] [PubMed]
  15. Rubin, J.M.; Li, S.; Fowlkes, J.B.; Sethuraman, S.; Kripfgans, O.D.; Shi, W.; Treadwell, M.C.; Jago, J.R.; Leichner, R.D.; Pinter, S.Z. Comparison of variations between spectral Doppler and Gaussian surface integration methods for umbilical vein blood volume flow. J. Ultrasound Med. 2021, 40, 369–376. [Google Scholar] [CrossRef] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Rubin, J.M.; Kripfgans, O.D. Comment on Barbieri et al. Umbilical Vein Blood Flow in Uncomplicated Pregnancies: Systematic Review of Available Reference Charts and Comparison with a New Cohort. J. Clin. Med. 2023, 12, 3132. J. Clin. Med. 2024, 13, 2347. https://doi.org/10.3390/jcm13082347

AMA Style

Rubin JM, Kripfgans OD. Comment on Barbieri et al. Umbilical Vein Blood Flow in Uncomplicated Pregnancies: Systematic Review of Available Reference Charts and Comparison with a New Cohort. J. Clin. Med. 2023, 12, 3132. Journal of Clinical Medicine. 2024; 13(8):2347. https://doi.org/10.3390/jcm13082347

Chicago/Turabian Style

Rubin, Jonathan M., and Oliver D. Kripfgans. 2024. "Comment on Barbieri et al. Umbilical Vein Blood Flow in Uncomplicated Pregnancies: Systematic Review of Available Reference Charts and Comparison with a New Cohort. J. Clin. Med. 2023, 12, 3132" Journal of Clinical Medicine 13, no. 8: 2347. https://doi.org/10.3390/jcm13082347

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop