Next Article in Journal
Extraction and Fractionation of Prokinetic Phytochemicals from Chrozophora tinctoria and Their Bioactivities
Next Article in Special Issue
A New Photoacoustic Soot Spectrophone for Filter-Free Measurements of Black Carbon at 880 nm
Previous Article in Journal
Nutritional Values of Minikiwi Fruit (Actinidia arguta) after Storage: Comparison between DCA New Technology and ULO and CA
Previous Article in Special Issue
Photoacoustic Effect of Near-Infrared Absorbing Organic Molecules via Click Chemistry
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

Spider Silk-Improved Quartz-Enhanced Conductance Spectroscopy for Medical Mask Humidity Sensing

1
Key Laboratory of Optoelectronic Information and Sensing Technologies of Guangdong Higher Education Institutes, Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
2
College of Traditional Chinese Medicine, Jinan University, Guangzhou 510630, China
3
Department of Preventive Treatment of Disease, The Affiliated TCM Hospital of Guangzhou Medical University, Guangzhou 510405, China
*
Authors to whom correspondence should be addressed.
Molecules 2022, 27(13), 4320; https://doi.org/10.3390/molecules27134320
Submission received: 24 May 2022 / Revised: 25 June 2022 / Accepted: 29 June 2022 / Published: 5 July 2022
(This article belongs to the Special Issue Recent Advances in Photoacoustic and Photothermal Gas Spectroscopy)

Abstract

:
Spider silk is one of the hottest biomaterials researched currently, due to its excellent mechanical properties. This work reports a novel humidity sensing platform based on a spider silk-modified quartz tuning fork (SSM-QTF). Since spider silk is a kind of natural moisture-sensitive material, it does not demand additional sensitization. Quartz-enhanced conductance spectroscopy (QECS) was combined with the SSM-QTF to access humidity sensing sensitively. The results indicate that the resonance frequency of the SSM-QTF decreased monotonously with the ambient humidity. The detection sensitivity of the proposed SSM-QTF sensor was 12.7 ppm at 1 min. The SSM-QTF sensor showed good linearity of ~0.99. Using this sensor, we successfully measured the humidity of disposable medical masks for different periods of wearing time. The results showed that even a 20 min wearing time can lead to a >70% humidity in the mask enclosed space. It is suggested that a disposable medical mask should be changed <2 h.

1. Introduction

Spider silk is well known for its outstanding mechanical properties. One of them is that spider silk is particularly sensitive to water [1]. When wetted or saturated in a high relative humidity (RH) atmosphere, spider silk ‘supercontracts’—unrestrained silk will shrink as much as 50% in length. The restrained silk generates stresses in excess of 50 MPa, which was discovered by Bell et al. and Guinea et al. [2,3]. The powerful water-collecting ability of spider silk is attributed to a unique fibrous structure consisting of periodic spindles and joints. The joints are composed of randomly scrambled, but neatly arranged nanofibers [4,5]. When the spider silk transitions from dry to wet conditions, the structure of spider silk will change to a joint to store water [6]. Water infiltrates the silk, disrupting the hydrogen bonding within the amorphous region of the proteins, which increases the molecular mobility to rearrange configurations [7,8,9,10]. This rearrangement results in the phenomenon of supercontraction that will change the modulus of the spider silk [11,12]. The spider silks are widely used in optical systems [13], the synthesis of new materials [14,15], biomedical applications [16,17,18,19,20,21] and tensile mechanics [22,23,24,25,26]. Spider silk also exhibits powerful cyclic contractions, which can be reversible and have reproducible use [9,27].
Quartz tuning forks (QTFs) have been traditionally used as a timing reference in wristwatches. The QTF is a bimorph cantilever based on the piezoelectric properties of the quartz [28]. The sensor consists of two prongs attached to a base, which is normally clamped to a holder. In order to make the mechanical movement of the fork tip work, an electrical field needs to be applied to the tuning fork tips, which is achieved by electroplating electrodes on the surface of the quartz [29]. Common materials attached to the QTF to improve the sensitivity include polystyrene (PS) nanofilm, polymethylmethacrylate (PMMA) nanowire, electrospun nanoporous wire, and a hydrogel conical tip, etc. [30,31,32,33,34]. The QTF’s remarkable advantages attract the attention of researchers, including its stable oscillation frequency, high quality factor, low power consumption, concise structure, and resistance to surrounding electromagnetic interference [35,36]. QTFs can be used in a wide temperature range from −40 °C to 85 °C and in an ultrahigh humidity environment [37]. Until now, QTFs have been used for micro force sensing, electric field intensity distribution detecting, charge distribution measurement, trace gas detection, polymer mechanical analysis, chemical/physical analysis and biosensing applications etc. [38,39,40,41,42,43,44,45,46,47,48]. A QTF sensor can be used for quantitative measurement of biomolecular interactions [49] or be used as an immunosensor for phenylketonuria diagnosis [50].
In this work, a sensitive and cost-effective humidity sensor was developed by using quartz-enhanced conductance spectroscopy (QECS) [51]. Compared with the spider silks as optical fibers for sensing applications, the QECS does not need to use optical instruments such as an optical spectrum analyzer for detection [25,26,52,53,54,55]. There is no requirement on the optical transmission of spider silk. The QECS has a quite remarkable advantage in self-sensing, since the results can be directly read out by means of electrical conductance spectroscopy and processed by a computer [51]. Compared to cantilevers or string resonators, there are no optics required for the QECS. Therefore, it will not introduce the thermoelastic noise and additional noise caused by the instability of the laser [56,57,58,59]. Due to the supercontraction ability of spider silk, the QTF was modified by natural spider silks to improve its humidity transducing ability. The developed humidity sensor was evaluated in different humid conditions, achieving a sensitivity of 12.7 ppm at 1 min. As proof of concept, the SSM-QTF sensor was used to measure the air humidity inside a medical mask to provide suggestions for mask wearing tips.

2. Experimental Setup for the Humidity Sensing System

QTFs were purchased from the Shenzhen XinChuangYue Electronic components Factory, with a resonance frequency of ~32.7 kHz and a Q factor of >60,000 in a sealed vacuum metallic package and ~10,000 in the air after removal of the metallic housing. The geometrical parameters were measured by an optical stereomicroscope. The prong length, prong width, and prong spacing of a QTF were 3.8 mm, 0.6 mm, and 0.3 mm, respectively. The effective spring constant of the QTF is ~20 kPa [48]. The effective elastic modulus of wet spider silk is ~17 GPa [60]. The detailed analysis of the structure and chemistry of spider silk can be found in references [61,62]. To attach spider silk onto a QTF, the metallic housing of a 3 × 8 mm QTF crystal was removed with two parallel prongs exposed. We obtained the spider silk from a Pterinochilus Murinus spider, which was fed in the laboratory. The spider silk was selected from the ampullate silk glands of a Pterinochilus Murinus spider. The spider silks are composed of tubiliform fibers, which are more sensitive to ambient humidity [47]. Without any sample pretreatment, the spider silk was bridged across the prongs of a QTF, forming a spider silk-modified QTF (SSM-QTF), as shown in Figure 1. A small amount of epoxy resin glue was used to glue the spider silk across the QTF prongs. The whole process was monitored by means of an optical microscope. The diameter of the microwire across the QTF prongs in Figure 1 was measured to be ~6 μm. Photographs of an SSM-QTF were taken with a Zeiss optical microscope.
To evaluate the humidity sensing performance of the SSM-QTF, we employed the experimental setup shown in Figure 2. The gas flow rate in the system was set to 20 standard cubic centimeters per minute (SCCM) by the mass flow controller (Alicat, Tucson, AZ, USA) to avoid gas flow noise. A pressure controller, pump, and valves were used to keep the pressure constant. The humidity in the chamber was controlled by a humidifier (Perma Pure, Lakewood, NJ, USA). In the gas stream, a commercial humidity sensor (Benetech GM1363B, Shenzhen, China) was also included for reference. The function generator (Tektronix AFG3102, Beverton, Oregon, USA) was used to produce sine waves with frequencies ranging from 32,500 Hz to 32,560 Hz with a fixed peak-to-peak amplitude of 400 mV. The SSM-QTF output electrical signals passed to a custom-made transimpedance preamplifier with a feedback resistance of 10 MΩ and were finally demodulated by a lock-in amplifier (SR830, Sunnyvale, CA, USA). The filter slope and time constant of the lock-in amplifier were set to 12 dB/Oct and 1 s, respectively. The demodulated signal was used to analyze the resonance QTF frequency, which varies with humidity. All experiments in this work were carried out at room temperature and atmospheric pressure. A LabVIEW program (Community Edition, National Instrument, Austin, TX, USA) was used to control the system, and all the measurements were performed automatically.
The resonance frequency f of the QTF can be expressed as [44,51]:
f Q T F = 1 2 π × k Q T F m Q T F ,   k Q T F = E Q T F w t 3 4 l 3
where the kQTF, mQTF, and EQTF are the spring constant, effective mass, and Young’s modulus, respectively. The t, l, and w are the QTF prong thickness, QTF prong length, and QTF prong width, respectively. We considered that the mass of the spider silk was negligible, i.e., dmQTFmQTF. The resonance frequency shift, after modification by the spider silk, can be expressed as:
d f Q T F = f Q T F 2 d k Q T F k Q T F
The resonance frequency shift can be attributed to the dkQTF value, which results from the spider silk spring constant ksilk. Due to the fact that the QTF and the spider silk were connected in parallel, the effective spring constant keff of the SSM-QTF can be expressed as:
E e f f k e f f = k Q T F + k s i l k
The electrical parameters of the SSM-QTF were measured by the abovementioned system in Figure 2, which is the same system as described in our previous publication [63]. The output of the conductance spectra was 1 spectrum/min, which was limited by the frequency scanning rate. The resonance frequency and Q factor of the SSM-QTF were calculated from a Lorenz curve fitting to the square of the amplitude associated with the conductance spectra [64].

3. Characterization of the Spider Silk-Modified Quartz Tuning Fork

A bare QTF without modification was also evaluated, under the same experimental conditions. The frequencies of the sine signals were scanned from 32,500 Hz to 32,560 Hz and from 32,725 Hz to 32,805 Hz with a step of 0.3 Hz for SSM-QTF and standard QTF, respectively. The resonance curves of the bare QTF and SSM-QTF are shown in Figure 3. In this work, we normalized the amplitude and focused on the frequency shift in the experiment. In the normalization, the amplitude of the highest signal was set as 1. Compared with a bare QTF, the resonance frequency peak of the SSM-QTF decreased from 32,764.9 Hz to 32,527.6 Hz, yielding a frequency shift of Δf = 241.3 Hz. This can be attributed to the mass increase caused by the spider silk and the glue.

4. Spider Silk-Based Tuning Fork for Humidity Sensing

Figure 4a shows the conductance spectra changed in the SSM-QTF with humidity. The Lorentz function was used to fit the resonance curve to obtain the QTF resonance frequency and Q factor. As shown in Figure 4b, the resonance frequency decreased monotonically from 32 541.80 Hz at ~25% RH to 32 514.85 Hz at ~80% RH, with a Δf = 25.95 Hz. This can be attributed to the modulus of spider silk being inversely proportional to the humidity; the effective modulus of the SSM-QTF decreased with the increase in the humidity [6]. The curve of Figure 4b was fitted using linear functions. An R square value of 0.99 was obtained. We also measured the frequency response of a bare QTF without the spider silk modification. No significant change was observed. The results are shown in the inset of Figure 4b, indicating that the large frequency shift Δf was caused by the spider silk, not the QTF itself.
Figure 4c shows the Q factors of the SSM-QTF with different humidities. As the humidity increased, the spider silk absorbs water molecules, increasing the additional mass attached to the QTF. In addition, as the humidity increased, the damping effect by the water absorption into spider silk increased; thus, the quality factor of the SSM-QTF decreased [65]. As a result, with the relative humidity increases from ~25% RH to ~80% RH, the Q factor decreased from 5253 to 2790, by >2400. For comparison, the Q factor change of a bare QTF without spider silk modification was <200, shown in the inset of Figure 4c. The quality factor of SSM-QTF decreased monotonically but nonlinearly. Therefore, in this work, we used the frequency as the function of humidity to develop the sensor. Since the resonance frequencies and quality factors were obtained after the QTF reaches a saturated steady state, no estimation was necessary for the saturation of the SSM-QTF surface. This implies that the effect of water adsorption in the modified spider silk area dominates that in the quartz surface.
The relative humidity (RH) was converted into absolute humidity by the Vaisala humidity calculator. With an absolute humidity change from 8042 ppm to 24,056 ppm, the detection sensitivity of the SSM-QTF was calculated to be ~12.7 ppm. This humidity dynamic range was limited by our gas stream system, which can be improved by a better humidifier. The comparison of the SSM-QTF with current technology such as optical fibers, cantilever, and string resonators are summarized in Table 1. Although the sensitivity of the SSM-QTF sensor was not the highest, there are no optics required in the developed sensor. Compared to current technologies, this work is cost-effective with a high performance.

5. Stability of Spider Silk-Modified QTF Sensor

The resonance frequency of the SSM-QTF was measured with a fixed relative humidity. The humidity in the gas chamber was well controlled by using a mass flow controller (Alicat Tucson, AZ, USA) with a relatively low flow rate but higher resolution. With a relative humidity of 20 ± 0.1% RH, a resonance frequency of 32,542.88 Hz was obtained. Since the relative humidity is sensitive to temperature, the ambient temperature condition has to be properly maintained throughout the experiment. For the tested humidity range, the temperature in the humidity chamber has been monitored to be ~24 °C. It can be seen from Figure 5 that the SSM-QTF sensor has good stability over long-term running. Allan deviation was performed to evaluate the long-term stability of the developed sensor. The minimum deviation of the SSM-QTF resonance frequency was found to be 1.316 × 10−3 Hz at the optimum time of ∼30 min. With the optimal integration time, the detection sensitivity can be improved to ~0.8 ppm.

6. Humidity Evaluation of Medical Masks

The COVID-19 pandemic has forced the global population to adopt new ways of living, including the possible use of masks. Research has been conducted to evaluate the potential consequences of wearing masks for long periods [66,67]. Among various research, the high humidity in the mask for a long wearing time can lead to excessive moisture to the skin, disrupting the skin barrier and causing sensitive skin [68,69]. Part of the moisture is the condensation of the breathed air. The other part is the sweat that does not evaporate as quickly. If the skin is exposed to moisture for a long time, the barrier of our keratin will be undermined [70]. When the skin barrier is broken, the ability to prevent the loss of water in the skin and the ability to block external stimuli are reduced. [71]. Furthermore, wearing a mask for a long time will cause high humidity in the air inside the mask, which will easily cause the breeding of various pathogenic bacteria and increase the risk of skin diseases [72,73]. For some patients with seborrheic dermatitis, Malassezia can multiply on the skin surface when wearing a medical mask for a long time [74].
In the measurement, the humidity inside a disposable medical mask made of polypropylene was evaluated. The disposable medical masks were worn by the author Leqing Lin for different periods; then, they were taken off quickly to cover the SSM-QTF sensor in a sealed space. The humidity of the covered air inside the medical mask was then measured. For each measurement, the medical mask was replaced by a new one. The time clock was restarted. Except for the wearing time, all the other conditions were the same in the repeated experiments. The enclosed spaces were set up to prevent humidity interference from the outside atmosphere. Resonance frequencies of the different wearing time of the masks were recorded by a LabVIEW program. The obtained results were shown in Figure 6. Even a 20 min wearing time resulted in an air humidity >70% RH in the mask covered space. The longer the mask was worn, the greater the humidity in the mask. With a 150 min wearing time, the estimated humidity reached >78%. In fact, the humidity measured in the mask covered space was lower than the actual humidity surrounding the human mouth. In consequence, disposable medical masks are not suitable for prolonged wearing. It is suggested to change the mask within 2 h, when the relative humidity on the surface of the mask is more than 75%. For professional masks, such as the KN95 medical masks, the case was estimated to be worse due to their better “protection”.

7. Conclusions

This work featured a novel humidity sensing platform based on a quartz tuning fork (QTF) with a section of natural spider silk. The experimental results showed that the higher the environmental humidity, the lower the resonance frequency of the spider silk-modified QTF. The variation of the resonance frequency of the QTF modified by spider silk was closely correlated with the change in the environmental humidity. The evaluation was conducted in relative humidity from ~25% RH to ~80% RH. The resonance curves were recorded to obtain the SSM-QTF frequency variations by Lorentz fitting. With a 1 min working time, the detection sensitivity of ~12.7 ppm was obtained.
As proof of concept, the humidities of disposable medical masks, worn for different periods, were evaluated. The results suggested that the masks should be changed every 2 h due to excessive humidity, which may cause potential facial skin discomfort. Currently, the acquisition time for the resonance frequency and Q factor requires ~1 min. This time can be shortened by narrowing the frequency scanning time and range. Allan deviation was measured over a long time with a fixed humidity. With 30 points of integration, the detection sensitivity can be improved to ~0.8 ppm. Future work will include the development of a wearable respiration sensor to measure the humidity inside a medical mask. Compared to the current electrochemistry sensor [75,76], the SSM-QTF sensor has the advantage of being cost-effective and environmentally friendly. In addition, temperature effects will be researched. The temperature and humidity may be monitored simultaneously with the help of a machine learning method.

Author Contributions

Conceptualization, L.L. and H.Z.; methodology, L.L.; software, C.W.; validation, Y.Z. (Yu Zhong); formal analysis, H.L.; resources, Z.Y., Y.P. and D.Z.; data curation, Q.W.; writing—original draft preparation, L.L.; writing—review and editing, H.Z. and W.Z.; visualization, Y.Z. (Yongchun Zhong); supervision, J.Y.; project administration, J.Y. and H.Z.; funding acquisition, J.Y. and H.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the National Key Research and Development Program of China (2021YFB2800801, 2019YFE0118200), the National Natural Science Foundation of China (12174156, 12174155, 62105125, 62005105, 62075088, 62175137), the Natural Science Foundation of Guangdong Province (2020B1515020024, 2019A1515011380), the Science and Technology Projects of Guangzhou (202102020445), the Key-Area Research and Development Program of Guangdong Province (2019B010138004), the Project of Guangzhou Industry Leading Talents (CXLJTD-201607), the Aeronautical Science Foundation of China (201808W4001), the Special Project in Key Fields of the Higher Education Institutions of Guangdong Province (2020ZDZX3022), the Open foundation of CEPREI (NO. 19D09), the Foundation for Distinguished Young Talents in Higher Education of Guangdong (2018KQNCX009), the Fundamental Research Funds for the Central Universities (21619402, 11618413), and the State Key Laboratory of Applied Optics (SKLAO-201914).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

We appreciate the natural spider silk from Yuwen Pan and Di Zhang.

Conflicts of Interest

The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

Sample Availability

Samples of the spider silk and QTFs are available from the authors.

References

  1. Liu, D.; Tarakanova, A.; Hsu, C.C.; Yu, M.; Zheng, S.; Yu, L.; Liu, J.; He, Y.; Dunstan, D.J.; Buehler, M.J. Spider dragline silk as torsional actuator driven by humidity. Sci. Adv. 2019, 5, eaau9183. [Google Scholar] [CrossRef] [Green Version]
  2. Bell, F.I.; McEwen, I.J.; Viney, C. Supercontraction stress in wet spider dragline. Nature 2002, 416, 37. [Google Scholar] [CrossRef]
  3. Guinea, G.V.; Elices, M.; Pérez-Rigueiro, J.; Plaza, G. Self-tightening of spider silk fibers induced by moisture. Polymer 2003, 44, 5785–5788. [Google Scholar] [CrossRef]
  4. Schafer, A.; Vehoff, T.; Glisovic, A.; Salditt, T. Spider silk softening by water uptake: An AFM study. Eur. Biophys. J. 2008, 37, 197–204. [Google Scholar] [CrossRef]
  5. Jelinski, L.W.; Blye, A.; Liivak, O.; Michal, C.; LaVerde, G.; Seidel, A.; Shah, N.; Yang, Z.T. Orientation, structure, wet-spinning, and molecular basis for supercontraction of spider dragline silk. Int. J. Biol. Macromol. 1999, 24, 197–201. [Google Scholar] [CrossRef]
  6. Vehoff, T.; Glišović, A.; Schollmeyer, H.; Zippelius, A.; Salditt, T. Mechanical properties of spider dragline silk: Humidity, hysteresis, and relaxation. Biophys. J. 2007, 93, 4425–4432. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Agnarsson, I.; Dhinojwala, A.; Sahni, V.; Blackledge, T.A. Spider silk as a novel high performance biomimetic muscle driven by humidity. J. Exp. Biol. 2009, 212, 1990–1994. [Google Scholar] [CrossRef] [Green Version]
  8. Liu, Z.; Liu, W.; Hu, C.; Zhang, Y.; Yang, X.; Zhang, J.; Yang, J.; Yuan, L. Natural spider silk as a photonics component for humidity sensing. Opt. Express 2019, 27, 21946–21955. [Google Scholar] [CrossRef] [PubMed]
  9. Blackledge, T.A.; Boutry, C.; Wong, S.C.; Baji, A.; Dhinojwala, A.; Sahni, V.; Agnarsson, I. How super is supercontraction? Persistent versus cyclic responses to humidity in spider dragline silk. J. Exp. Biol. 2009, 212, 1980–1988. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  10. Guan, J.; Vollrath, F.; Porter, D. Two mechanisms for supercontraction in Nephila spider dragline silk. Biomacromolecules 2011, 12, 4030–4035. [Google Scholar] [CrossRef] [PubMed]
  11. Liu, Z.; Zhang, M.; Zhang, Y.; Xu, Y.; Zhang, Y.X.; Yang, X.H.; Zhang, J.Z.; Yang, J.; Yuan, L.B. Spider silk-based humidity sensor. Opt. Lett. 2019, 44, 2907–2910. [Google Scholar] [CrossRef]
  12. Liu, Z.; Zhang, M.; Zhang, Y.; Xu, Y.; Zhang, Y.X.; Yang, X.H.; Zhang, J.Z.; Yang, J.; Yuan, L.B. Spider silk-based tapered optical fiber for humidity sensing based on multimode interference. Sens. Actuators A Phys. 2020, 313, 112179. [Google Scholar] [CrossRef]
  13. Lin, C.B.; Lin, Y.H.; Chen, W.Y.; Liu, C.Y. Photonic Nanojet Modulation Achieved by a Spider-Silk-Based Metal–Dielectric Dome Microlens. Photonics 2021, 8, 334. [Google Scholar] [CrossRef]
  14. Mohammadi, P.; Zemke, F.; Wagermaier, W.; Linder, M.B. Interfacial crystallization and supramolecular self-assembly of spider silk inspired protein at the water-air interface. Materials 2021, 14, 4239. [Google Scholar] [CrossRef]
  15. Müller, F.; Zainuddin, S.; Scheibel, T. Roll-to-roll production of spider silk nanofiber nonwoven meshes using centrifugal electrospinning for filtration applications. Molecules 2020, 25, 5540. [Google Scholar] [CrossRef]
  16. Lai, W.L.; Goh, K.L. Consequences of ultra-violet irradiation on the mechanical properties of spider silk. J. Funct. Biomater. 2015, 6, 901–916. [Google Scholar] [CrossRef] [Green Version]
  17. Resch, A.; Wolf, S.; Mann, A.; Weiss, T.; Stetco, A.L.; Radtke, C. Co-culturing human adipose derived stem cells and schwann cells on spider silk-A new approach as prerequisite for enhanced nerve regeneration. Int. J. Mol. Sci. 2018, 20, 71. [Google Scholar] [CrossRef] [Green Version]
  18. Salehi, S.; Koeck, K.; Scheibel, T. Spider silk for tissue engineering applications. Molecules 2020, 25, 737. [Google Scholar] [CrossRef] [Green Version]
  19. Kiseleva, A.P.; Kiselev, G.O.; Nikolaeva, V.O.; Seisenbaeva, G.; Kessler, V.; Krivoshapkin, P.V.; Krivoshapkina, E.F. Hybrid spider silk with inorganic nanomaterials. Nanomaterials 2020, 10, 1853. [Google Scholar] [CrossRef]
  20. Schlottmann, F.; Strauss, S.; Plaass, C.; Welke, B.; Vogt, P.M.; Kuhbier, J.W. Spider Silk-Augmented Scaffolds and Adipose-Derived Stromal Cells Loaded with Uniaxial Cyclic Strain: First Investigations of a Novel Approach for Tendon-Like Constructs. Appl. Sci. 2021, 11, 1218. [Google Scholar] [CrossRef]
  21. Withanage, S.; Savin, A.; Nikolaeva, V.; Kiseleva, A.; Dukhinova, M.; Krivoshapkin, P.; Krivoshapkina, E. Native spider silk-based antimicrobial hydrogels for biomedical applications. Polymers 2021, 13, 1796. [Google Scholar] [CrossRef] [PubMed]
  22. Greco, G.; Francis, J.; Arndt, T.; Schmuck, B.; Bäcklund, F.G.; Barth, A.; Rising, A. Properties of biomimetic artificial spider silk fibers tuned by postspin bath incubation. Molecules 2020, 25, 3248. [Google Scholar] [CrossRef] [PubMed]
  23. Fraternali, F.; Stehling, N.; Amendola, A.; Tiban Anrango, B.A.; Holland, C.; Rodenburg, C. Tensegrity modelling and the high toughness of spider dragline silk. Nanomaterials 2020, 10, 1510. [Google Scholar] [CrossRef] [PubMed]
  24. Pérez-Rigueiro, J.; Elices, M.; Plaza, G.R.; Guinea, G.V. Basic principles in the design of spider silk fibers. Molecules 2021, 26, 1794. [Google Scholar] [CrossRef]
  25. Greco, G.; Pugno, N.M. Mechanical properties and Weibull Scaling Laws of unknown spider silks. Molecules 2020, 25, 2938. [Google Scholar] [CrossRef]
  26. Arndt, T.; Greco, G.; Schmuck, B.; Bunz, J.; Shilkova, O.; Francis, J.; Rising, A. Engineered Spider Silk Proteins for Biomimetic Spinning of Fibers with Toughness Equal to DragLine Silks. Adv. Funct. Mater. 2022, 32, 2200986. [Google Scholar] [CrossRef]
  27. Velmurugan, J.; Agrawal, A.; An, S.; Choudhary, E.; Szalai, V.A. Fabrication of scanning electrochemical microscopy-atomic force microscopy probes to image surface topography and reactivity at the nanoscale. Anal. Chem. 2017, 89, 2687–2691. [Google Scholar] [CrossRef] [Green Version]
  28. Li, Y.; Zhang, L.; Shan, G.; Song, Z.; Yang, R.; Li, H.; Qian, J. A homemade atomic force microscope based on a quartz tuning fork for undergraduate instruction. Am. J. Phys. 2016, 84, 478–482. [Google Scholar] [CrossRef]
  29. Oria, R.; Otero, J.; González, L.; Botaya, L.; Carmona, M.; Puig-Vidal, M. Finite element analysis of electrically excited quartz tuning fork devices. Sensors 2013, 13, 7156–7169. [Google Scholar] [CrossRef] [Green Version]
  30. Yun, M.; Lee, S.; Yim, C.; Jung, N.; Thundat, T.; Jeon, S. Suspended polymer nanobridge on a quartz resonator. Appl. Phys. Lett. 2013, 103, 053109. [Google Scholar] [CrossRef] [Green Version]
  31. Kim, W.; Yun, M.; Lee, S.; Jeon, S. Enhanced sensitivity of quartz tuning fork sensors using electrospun polymer wires. RSC Adv. 2016, 6, 31131–31134. [Google Scholar] [CrossRef] [Green Version]
  32. Hwang, S.; Kim, W.; Yoon, H.; Jeon, S. Performance Enhancement of a Microfabricated Resonator Using Electrospun Nanoporous Polymer Wire. ACS Sens. 2017, 2, 1355–1358. [Google Scholar] [CrossRef]
  33. Ko, J.; Jarzembski, A.; Park, K.; Lee, J. Hydrogel tip attached quartz tuning fork for shear force microscopy. Micro Nano Syst. Lett. 2018, 6, 8. [Google Scholar] [CrossRef]
  34. Gonzalez, L.; Martínez-Martín, D.; Otero, J.; De Pablo, P.J.; Puig-Vidal, M.; Gómez-Herrero, J. Improving the lateral resolution of quartz tuning fork-based sensors in liquid by integrating commercial AFM tips into the fiber end. Sensors 2015, 15, 1601–1610. [Google Scholar] [CrossRef] [Green Version]
  35. Lin, H.; Zheng, H.; Montano, B.A.Z.; Wu, H.; Giglio, M.; Sampaolo, A.; Spagnolo, V. Ppb-level gas detection using on-beam quartz-enhanced photoacoustic spectroscopy based on a 28 kHz tuning fork. Photoacoustics 2022, 25, 100321. [Google Scholar] [CrossRef]
  36. Zheng, H.; Liu, Y.; Lin, H.; Liu, B.; Gu, X.; Li, D.; Tittel, F.K. Quartz-enhanced photoacoustic spectroscopy employing pilot line manufactured custom tuning forks. Photoacoustics 2020, 17, 100158. [Google Scholar] [CrossRef]
  37. Ko, J.; Yoon, Y.; Lee, J. Quartz tuning forks with hydrogel patterned by dynamic mask lithography for humidity sensing. Sens. Actuators B Chem. 2018, 273, 821–825. [Google Scholar] [CrossRef]
  38. Barbic, M.; Eliason, L.; Ranshaw, J. Femto-Newton force sensitivity quartz tuning fork sensor. Sens. Actuators A Phys. 2007, 136, 564–566. [Google Scholar] [CrossRef]
  39. Paetzold, U.W.; Lehnen, S.; Bittkau, K.; Rau, U.; Carius, R. Nanoscale observation of waveguide modes enhancing the efficiency of solar cells. Nano Lett. 2014, 14, 6599–6605. [Google Scholar] [CrossRef]
  40. Giessibl, F.J. High-speed force sensor for force microscopy and profilometry utilizing a quartz tuning fork. Appl. Phys. Lett. 1998, 73, 3956–3958. [Google Scholar] [CrossRef]
  41. Breitegger, P.; Schweighofer, B.; Wegleiter, H.; Knoll, M.; Lang, B.; Bergmann, A. Towards low-cost QEPAS sensors for nitrogen dioxide detection. Photoacoustics 2020, 18, 100169. [Google Scholar] [CrossRef]
  42. Li, B.; Feng, C.; Wu, H.; Jia, S.; Dong, L. Calibration-free mid-infrared exhaled breath sensor based on BF-QEPAS for real-time ammonia measurements at ppb level. Sens. Actuators B Chem. 2022, 358, 131510. [Google Scholar] [CrossRef]
  43. Qiao, S.; Ma, Y.; He, Y.; Patimisco, P.; Sampaolo, A.; Spagnolo, V. Ppt level carbon monoxide detection based on light-induced thermoelastic spectroscopy exploring custom quartz tuning forks and a mid-infrared QCL. Opt. Express 2021, 29, 25100–25108. [Google Scholar] [CrossRef]
  44. Li, S.; Sun, B.; Shang, Z.; Li, B.; Cui, R.; Wu, H.; Dong, L. Quartz Enhanced Conductance Spectroscopy for Polymer Nano-Mechanical Thermal Analysis. Appl. Sci. 2020, 10, 4954. [Google Scholar] [CrossRef]
  45. Wu, H.; Dong, L.; Yin, X.; Sampaolo, A.; Patimisco, P.; Ma, W.; Jia, S. Atmospheric CH4 measurement near a landfill using an ICL-based QEPAS sensor with VT relaxation self-calibration. Sens. Actuators B Chem. 2019, 297, 126753. [Google Scholar] [CrossRef]
  46. Yin, X.; Wu, H.; Dong, L.; Li, B.; Ma, W.; Zhang, L.; Tittel, F.K. Ppb-level SO2 photoacoustic sensors with a suppressed absorption-desorption effect by using a 7.41 μm external-cavity quantum cascade laser. ACS Sens. 2020, 5, 549–556. [Google Scholar] [CrossRef]
  47. Kim, W.; Park, E.; Jeon, S. Performance enhancement of a quartz tuning fork sensor using a cellulose nanocrystal-reinforced nanoporous polymer fiber. Sensors 2020, 20, 437. [Google Scholar] [CrossRef] [Green Version]
  48. Ren, M.; Forzani, E.S.; Tao, N. Chemical sensor based on microfabricated wristwatch tuning forks. Anal. Chem. 2005, 77, 2700–2707. [Google Scholar] [CrossRef]
  49. Gonzalez, L.; Rodrigues, M.; Benito, M.; Pérez-García, L.; Puig-Vidal, M.; Otero, J. Piezoelectric tuning fork biosensors for the quantitative measurement of biomolecular interactions. Nanotechnology 2015, 26, 495502. [Google Scholar] [CrossRef]
  50. Kaleli-Can, G.; Özgüzar, H.F.; Mutlu, M. Development of QTF-based mass-sensitive immunosensor for phenylketonuria diagnosis. Appl. Phys. A 2022, 128, 277. [Google Scholar] [CrossRef]
  51. Zheng, H.; Yin, X.; Zhang, G.; Dong, L.; Wu, H.; Liu, X.; Tittel, F.K. Quartz-enhanced conductance spectroscopy for nanomechanical analysis of polymer wire. Appl. Phys. Lett. 2015, 107, 221903. [Google Scholar] [CrossRef] [Green Version]
  52. Tow, K.H.; Chow, D.M.; Vollrath, F.; Dicaire, I.; Gheysens, T.; Thévenaz, L. Exploring the use of native spider silk as an optical fiber for chemical sensing. J. Lightwave Technol. 2018, 36, 1138–1144. [Google Scholar] [CrossRef] [Green Version]
  53. Qiao, X.; Qian, Z.; Li, J.; Sun, H.; Han, Y.; Xia, X.; Wang, C. Synthetic engineering of spider silk fiber as implantable optical waveguides for low-loss light guiding. ACS Appl. Mater. Interfaces 2017, 9, 14665–14676. [Google Scholar] [CrossRef] [PubMed]
  54. Wang, J.; Zhang, H.; Tang, Y.; Wen, M.; Yao, B.; Yuan, S.; Zhang, W.; Lei, H. Metal-Nanostructure-Decorated Spider Silk for Highly Sensitive Refractive Index Sensing. ACS Biomater. Sci. Eng. 2022, 8, 1060–1066. [Google Scholar] [CrossRef]
  55. Huby, N.; Vié, V.; Renault, A.; Beaufils, S.; Lefèvre, T.; Paquet-Mercier, F.; Bêche, B. Native spider silk as a biological optical fiber. Appl. Phys. Lett. 2013, 102, 123702. [Google Scholar] [CrossRef] [Green Version]
  56. Mistry, K.; Nguyen, V.H.; Arabi, M.; Ibrahim, K.H.; Asgarimoghaddam, H.; Yavuz, M.; Musselman, K.P. Highly Sensitive Self-Actuated Zinc Oxide Resonant Microcantilever Humidity Sensor. Nano Lett. 2022, 22, 3196–3203. [Google Scholar] [CrossRef]
  57. Schmid, S.; Jensen, K.D.; Nielsen, K.H.; Boisen, A. Damping mechanisms in high-Q micro and nanomechanical string resonators. Phys. Rev. B 2011, 84, 165307. [Google Scholar] [CrossRef] [Green Version]
  58. Yoon, Y.; Thundat, T.; Lee, J. Resonant hair humidity sensors for disposable applications: Revisit the hair hygrometer. Sens. Actuators B Chem. 2019, 292, 1–6. [Google Scholar] [CrossRef]
  59. González, L.; Otero, J.; Cabezas, G.; Puig-Vidal, M. Electronic driver with amplitude and quality factor control to adjust the response of quartz tuning fork sensors in atomic force microscopy applications. Sens. Actuators A Phys. 2012, 184, 112–118. [Google Scholar] [CrossRef]
  60. Humenik, M.; Scheibel, T.; Smith, A. Spider silk: Understanding the structure-function relationship of a natural fiber. Prog. Mol. Biol. Transl. Sci. 2011, 103, 131–185. [Google Scholar]
  61. Asakura, T. Structure and dynamics of spider silk studied with solid-state nuclear magnetic resonance and molecular dynamics simulation. Molecules 2020, 25, 2634. [Google Scholar] [CrossRef]
  62. Du, N.; Liu, X.Y.; Narayanan, J.; Li, L.; Lim, M.L.M.; Li, D. Design of superior spider silk: From nanostructure to mechanical properties. Biophys. J. 2006, 91, 4528–4535. [Google Scholar] [CrossRef] [Green Version]
  63. Wu, H.; Dong, L.; Zheng, H.; Yu, Y.; Ma, W.; Zhang, L.; Tittel, F.K. Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring. Nat. Commun. 2017, 8, 15331. [Google Scholar] [CrossRef] [Green Version]
  64. Kosterev, A.A.; Tittel, F.K.; Serebryakov, D.V.; Malinovsky, A.L.; Morozov, I.V. Applications of quartz tuning forks in spectroscopic gas sensing. Rev. Sci. Instrum. 2005, 76, 043105. [Google Scholar] [CrossRef] [Green Version]
  65. Castellanos-Gomez, A.; Agraït, N.; Rubio-Bollinger, G. Dynamics of quartz tuning fork force sensors used in scanning probe microscopy. Nanotechnology 2009, 20, 215502. [Google Scholar] [CrossRef]
  66. Szepietowski, J.C.; Matusiak, Ł.; Szepietowska, M.; Krajewski, P.K.; Białynicki-Birula, R. Face Mask-induced Itch: A Self-questionnaire Study of 2,315 Responders During the COVID-19 Pandemic. Acta Derm. Venereol. 2020, 100, 00152. [Google Scholar] [CrossRef]
  67. De Acevedo Chávez, B.G.; Miranda, G.A.; Mosqueda, R.A.; Gómez, M.I.A.; Martínez, J.C.; Gómez, A.M.; Hink, H.M. Cutaneous manifestations secondary to the COVID-19 pandemic. Acta Médica Grupo Ángeles 2021, 19, s27–s36. [Google Scholar]
  68. İnan Doğan, E.; Kaya, F. Dermatological findings in patients admitting to dermatology clinic after using face masks during Covid-19 pandemia: A new health problem. Dermatol. Ther. 2021, 34, e14934. [Google Scholar] [CrossRef]
  69. Abdali, S.; Yu, J. Occupational Dermatoses Related to Personal Protective Equipment Used During the COVID-19 Pandemic. Dermatol. Clin. 2021, 39, 555–568. [Google Scholar] [CrossRef]
  70. Warner, R.R.; Stone, K.J.; Boissy, Y.L. Hydration disrupts human stratum corneum ultrastructure. J. Investig. Dermatol. 2003, 120, 275–284. [Google Scholar] [CrossRef] [Green Version]
  71. Han, H.S.; Shin, S.H.; Park, J.W.; Li, K.; Kim, B.J.; Yoo, K.H. Changes in skin characteristics after using respiratory protective equipment (medical masks and respirators) in the COVID-19 pandemic among healthcare workers. Contact Dermat. 2021, 85, 225–232. [Google Scholar] [CrossRef]
  72. Paichitrojjana, A. Demodicosis Associated with Wearing a Face Mask: A Case Report. Case Rep. Dermatol. 2022, 14, 19–23. [Google Scholar] [CrossRef]
  73. Damiani, G.; Gironi, L.C.; Grada, A.; Kridin, K.; Finelli, R.; Buja, A.; Savoia, P. COVID-19 related masks increase severity of both acne (maskne) and rosacea (mask rosacea): Multi-center, real-life, telemedical, and observational prospective study. Dermatol. Ther. 2021, 34, e14848. [Google Scholar] [CrossRef]
  74. Darlenski, R.; Kazandjieva, J.; Tsankov, N. Prevention and occupational hazards for the skin during COVID-19 pandemic. Clin. Dermatol. 2021, 39, 92–97. [Google Scholar] [CrossRef]
  75. Wang, Y.; Zhang, L.; Zhang, Z.; Sun, P.; Chen, H. High-sensitivity wearable and flexible humidity sensor based on graphene oxide/non-woven fabric for respiration monitoring. Langmuir 2020, 36, 9443–9448. [Google Scholar] [CrossRef]
  76. Pang, Y.; Jian, J.; Tu, T.; Yang, Z.; Ling, J.; Li, Y.; Ren, T.L. Wearable humidity sensor based on porous graphene network for respiration monitoring. Biosens. Bioelectron. 2018, 116, 123–129. [Google Scholar] [CrossRef]
Figure 1. Photographs of an SSM-QTF taken with a Zeiss optical microscope. (b) is the enlarged view of (a).
Figure 1. Photographs of an SSM-QTF taken with a Zeiss optical microscope. (b) is the enlarged view of (a).
Molecules 27 04320 g001
Figure 2. Experimental setup for humidity sensing. SSM-QTF: spider silk-modified QTF; TA: transimpedance amplifier; PC: personal computer; Lock-in: lock-in amplifier, MFC: mass flow controller.
Figure 2. Experimental setup for humidity sensing. SSM-QTF: spider silk-modified QTF; TA: transimpedance amplifier; PC: personal computer; Lock-in: lock-in amplifier, MFC: mass flow controller.
Molecules 27 04320 g002
Figure 3. Conductance spectrum of a bare QTF without modification (red rounds) and after (black squares) modification by the spider silk.
Figure 3. Conductance spectrum of a bare QTF without modification (red rounds) and after (black squares) modification by the spider silk.
Molecules 27 04320 g003
Figure 4. (a) Resonance curves of the SSM-QTF at different humidities. (b) Frequency variations of an SSM-QTF as a function of humidity. The figure inset shows the resonance frequency variations of a bare QTF. (c) Q factor variations of an SSM-QTF as a function of humidity. The figure inset shows the resonance frequency variations of a bare QTF.
Figure 4. (a) Resonance curves of the SSM-QTF at different humidities. (b) Frequency variations of an SSM-QTF as a function of humidity. The figure inset shows the resonance frequency variations of a bare QTF. (c) Q factor variations of an SSM-QTF as a function of humidity. The figure inset shows the resonance frequency variations of a bare QTF.
Molecules 27 04320 g004
Figure 5. (a) Resonance frequency of the SSM-QTF and relative humidity measured for 160 min with the relative humidity controlled to be ~20% RH. (b) Allan deviations obtained by the SSM-QTF-based QECS systems.
Figure 5. (a) Resonance frequency of the SSM-QTF and relative humidity measured for 160 min with the relative humidity controlled to be ~20% RH. (b) Allan deviations obtained by the SSM-QTF-based QECS systems.
Molecules 27 04320 g005
Figure 6. Resonance frequency variations of the SSM-QTF of the humidity inside the mask for different wearing times.
Figure 6. Resonance frequency variations of the SSM-QTF of the humidity inside the mask for different wearing times.
Molecules 27 04320 g006
Table 1. Comparison of the SSM-QTF with optical fibers, cantilever, and string resonators.
Table 1. Comparison of the SSM-QTF with optical fibers, cantilever, and string resonators.
ConfigurationSensitivityOptics
optical fiber [12]532 ppm/%RHsuper-continuum laser
cantilever [26]924 ppm/%RHlaser doppler vibrometer
string resonator [56]2950 ppm/%RHlaser doppler vibrometer
SSM-QTF sensor617 ppm/%RHnone
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Lin, L.; Zhong, Y.; Lin, H.; Wang, C.; Yang, Z.; Wu, Q.; Zhang, D.; Zhu, W.; Zhong, Y.; Pan, Y.; et al. Spider Silk-Improved Quartz-Enhanced Conductance Spectroscopy for Medical Mask Humidity Sensing. Molecules 2022, 27, 4320. https://doi.org/10.3390/molecules27134320

AMA Style

Lin L, Zhong Y, Lin H, Wang C, Yang Z, Wu Q, Zhang D, Zhu W, Zhong Y, Pan Y, et al. Spider Silk-Improved Quartz-Enhanced Conductance Spectroscopy for Medical Mask Humidity Sensing. Molecules. 2022; 27(13):4320. https://doi.org/10.3390/molecules27134320

Chicago/Turabian Style

Lin, Leqing, Yu Zhong, Haoyang Lin, Chenglong Wang, Zhifei Yang, Qian Wu, Di Zhang, Wenguo Zhu, Yongchun Zhong, Yuwei Pan, and et al. 2022. "Spider Silk-Improved Quartz-Enhanced Conductance Spectroscopy for Medical Mask Humidity Sensing" Molecules 27, no. 13: 4320. https://doi.org/10.3390/molecules27134320

APA Style

Lin, L., Zhong, Y., Lin, H., Wang, C., Yang, Z., Wu, Q., Zhang, D., Zhu, W., Zhong, Y., Pan, Y., Yu, J., & Zheng, H. (2022). Spider Silk-Improved Quartz-Enhanced Conductance Spectroscopy for Medical Mask Humidity Sensing. Molecules, 27(13), 4320. https://doi.org/10.3390/molecules27134320

Article Metrics

Back to TopTop