Erratum: Toro, C. et al. On the Detection of Spectral Emissions of Iron Oxides in Combustion Experiments of Pyrite Concentrates. Sensors 2020, 20, 1284
Figure 9. Non-linear curve fitting results for a spectrum from combustion of PyE sample, RMSE (root mean square error) = 0.4393, θ0 = 0.0249, Ts = 2220.3 K, θ1 (related to I1 or Na) = 3.4583, θ2 (related to I2 or Na) = 15.7373, θ3 (related to I3 or FeO) = 6.2484, θ4 (related to I4 or Fe3O4) = 7.3093 and θ5 (related to an offset) = 9.6 × 10-8.
Reference
- Toro, C.; Torres, S.; Parra, V.; Fuentes, R.; Castillo, R.; Diaz, W.; Reyes, G.; Balladares, E.; Parra, R. On the Detection of Spectral Emissions of Iron Oxides in Combustion Experiments of Pyrite Concentrates. Sensors 2020, 20, 1284. [Google Scholar] [CrossRef] [Green Version]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Toro, C.; Torres, S.; Parra, V.; Fuentes, R.; Castillo, R.; Díaz, W.; Reyes, G.; Balladares, E.; Parra, R. Erratum: Toro, C. et al. On the Detection of Spectral Emissions of Iron Oxides in Combustion Experiments of Pyrite Concentrates. Sensors 2020, 20, 1284. Sensors 2020, 20, 6141. https://doi.org/10.3390/s20216141
Toro C, Torres S, Parra V, Fuentes R, Castillo R, Díaz W, Reyes G, Balladares E, Parra R. Erratum: Toro, C. et al. On the Detection of Spectral Emissions of Iron Oxides in Combustion Experiments of Pyrite Concentrates. Sensors 2020, 20, 1284. Sensors. 2020; 20(21):6141. https://doi.org/10.3390/s20216141
Chicago/Turabian StyleToro, Carlos, Sergio Torres, Víctor Parra, Rodrigo Fuentes, Rosario Castillo, Walter Díaz, Gonzalo Reyes, Eduardo Balladares, and Roberto Parra. 2020. "Erratum: Toro, C. et al. On the Detection of Spectral Emissions of Iron Oxides in Combustion Experiments of Pyrite Concentrates. Sensors 2020, 20, 1284" Sensors 20, no. 21: 6141. https://doi.org/10.3390/s20216141
APA StyleToro, C., Torres, S., Parra, V., Fuentes, R., Castillo, R., Díaz, W., Reyes, G., Balladares, E., & Parra, R. (2020). Erratum: Toro, C. et al. On the Detection of Spectral Emissions of Iron Oxides in Combustion Experiments of Pyrite Concentrates. Sensors 2020, 20, 1284. Sensors, 20(21), 6141. https://doi.org/10.3390/s20216141