1. Introduction
Ice hockey sticks are a growing segment of the USD 850+ million hockey equipment market due to increasing global hockey participation and short product shelf life [
1]. It is estimated that hockey sticks alone will reach a market value of USD 320 million by the end of 2025 [
2]. Since players first began to modify their wooden sticks in the mid-20th century, the technologies, materials, and customizability of hockey sticks has improved greatly [
3]. Today, players can purchase off the shelf sticks of various linear bending stiffnesses (“flex”), blade patterns (“curve” and “lie”), and dynamic flex profiles (“kick point”) with the rationale that different stick properties can enhance a player’s on-ice performance, such as shot speed, by “fitting” to their technique and/or style of play. During the shooting motion, the hockey stick functionally acts as a spring by releasing energy at a faster rate than it was previously stored, amplifying shot power.
Research on the influence of stick flex on shooting performance to date has been conflicted; however, it appears that players should select their flex based on the way they load the hockey stick. Three possible stick “loading styles” have been reported in the literature. These are Constant Displacement, Constant Force, and Constant Energy [
4,
5]. In each loading style, a player affects a constant maximal deformation of the shaft, applies an identical level of force, or stores the same maximal amount of energy in the stick regardless of changes in shaft stiffness. At present, the exact origins of these disparate stick loading styles remain unknown; however, there is evidence that such differences may arise due to differences in anthropometrics, kinematics, and levels of experience. For example, it is believed that larger, stronger players may be able to use a Constant Displacement model while weaker players may follow a Constant Force model [
4]. Others have proposed that players have adopted new shooting techniques to take advantage of the spring-like properties of modern carbon composite hockey sticks [
3]. These theories are consistent with previous findings that stick stiffness may negatively affect the shot velocities of younger [
6] or female [
7] players by preventing them from realizing the full power-amplifying benefits of the stick. These findings suggest that players should be provided tailored recommendations of shaft stiffness based on their specific loading style.
Sticks are designed to have specific kick points to maximize specific shot performance parameters, such as speed, accuracy, and quickness. Kick points are commonly referred to by the desired location of maximum deflection within the shaft. For example, a low-kick-point stick is most flexible at the bottom and increases in stiffness moving up the shaft while a high-kick-point stick is stiffest at the bottom. Published academic research on the effect of stick dynamic flex profiles is scarce. However, it is generally believed that low-kick-point sticks assist with release quickness while high-kick-point sticks are best for maximizing stick bend and puck velocity [
8].
Research on the effect of blade patterns has shown that flatter curves may enhance shot speed by affecting the spatiotemporal characteristics of blade and stick loading during the slap shot [
9]. This may occur due to systematically decreased lag between blade–toe and blade–heel ice contact similar to how advanced hockey players achieve higher puck speeds by “pinning” the stick blade earlier and storing more strain potential energy in the stick [
10]. In contrast, the very origin of blade curves was to provide players with added levels of puck control [
11]. Mechanically, more “open” curves make it easier to apply lift to the puck and consequently reach the upper net on forehand shots while a more pronounced curve and proper lie aid in puck control.
While hockey stick technologies have evolved drastically over the past twenty-five years, the means to fit players for them have been much slower to change; players still buy sticks mainly in retail stores without much knowledge of which may work best for them. The data-driven process of matching players with the best stick for them is called “stick fitting”. In recent years, with the incorporation of scanning technologies for hockey equipment fitting in retail settings, demand has grown for systems that are able to fit players quickly with little cost, floor space, or manpower required by the retailer. Previous research has shown that automated computer vision algorithms can evaluate shot performance metrics with comparable accuracy to more expensive and cumbersome motion capture systems [
12]; however, the lengthy computation time (111 s/frame) makes it challenging to implement this automated, low-cost technology in retail settings. Instead, many hockey equipment retailers use 2D slow-motion video analysis apps, such as CCM Hockey’s Stick Fitter and Bauer Hockey’s Stick Studio, for stick fitting. No research has yet explored the combination of embedded sensors and machine learning algorithms for the purpose of automating stick fitting, providing recommendations of stick parameters more rapidly to players based on objective measures of shooting performance.
The aim of this study was to evaluate the feasibility of using inertial measurement unit sensors (IMUs) and machine learning algorithms for the stick fitting of experienced ice hockey players. This was an exploratory study on the use of in-glove IMUs in a hockey shooting context; however, motivation was derived from previous studies that have used kinematic signals obtained using IMUs and machine learning algorithms to classify athletic movement patterns [
13,
14], including those specific to ice hockey [
15,
16]. It was hypothesized that differences in hand kinematics would be characteristic of different responses to stick flex, blade pattern, and kick point.
2. Materials and Methods
2.1. Participants
Ten experienced male ice hockey players were recruited for this study. Two participants had experience at the Junior A level, five at the Canadian/American university level, and three at the professional level (
Table 1). All participants had played hockey in the past calendar year and were free of serious injuries at the time of data collection. Descriptive statistics of the participants are provided in
Table 1.
2.2. Instrumentation and Data Collection
Testing took place in the Biomechanics and Performance Analysis Lab at McGill University’s Currie Gymnasium in Montreal, Quebec. Testing procedures were explained in written and oral format to the participants, who then provided informed written consent prior to data collection.
An 18-camera Vicon optoelectronic system (Vicon, Oxford, UK) was used to capture three-dimensional kinematics of the body, stick, and puck during testing. These data were necessary to identify key shot events and calculate puck velocity (shot speed), radial error from target center at net entry (shot accuracy), and contact time with the stick blade (shot quickness). The formula of Hancock et al. [
17] was used to calculate radial error, where x represents the horizontal distance between the puck center and target center and z represents the vertical distance between the puck center and target center at net entry:
The Vicon system consisted of eight T10S, two T40S, four Vantage V5, and four Vero 2.2 cameras, which were positioned on tripods of varying heights around a synthetic ice surface (Viking, Toronto, ON, Canada) (
Figure 1), providing a capture volume approximately 8.0 m long × 3.4 m wide × 2.0 m high. The cameras were connected to an MX Giganet connection Hub and desktop computer (Nexus 2.6, Vicon, Oxford, UK) and recorded at a sampling rate of 240 Hz.
After obtaining informed written consent, anthropometric measurements were taken and participants were fitted with a full-body, tight-fitting Velcro suit (OptiTrack, Corvallis, OR, USA). Fifty-two spherical retroreflective markers with a diameter of 14 mm were placed on the participant in accordance with an adapted version of the Plug-in Gait full-body model (
Figure 2). Four markers were placed on the puck and ten along each stick (
Figure 2) to measure puck and stick kinematics, respectively. An additional eight markers were placed along the posts and crossbar of the net to compute puck-to-target accuracy measures.
Prior to the start of testing, participants recorded a static calibration pose held by each participant for five seconds with the arms parallel with the floor and elbow bent to 90°. This calibration was required to determine the model of each participant’s initial coordinate system reference frame. After the static calibration trial was recorded, participants were given time to warm-up and get accustomed to the synthetic ice surface by taking practice shots on the net.
Bespoke IMUs (Motsai Research, Saint-Bruno-de-Montarville, QC, Canada) were inserted in an opening in the thumb segment of each glove during testing to capture concurrent kinematics of the hands. This instrumentation configuration was chosen to ensure the IMU placement would not affect players’ shooting technique during data collection and could be easily replicated in a real-world fitting context. Data capture for the IMU system was initiated by a second researcher using a custom-built tablet application (Bauer Hockey Ltd., Blainville, QC, Canada) over Wi-Fi connection. The IMUs comprised an accelerometer capturing linear acceleration in gravitational units and a gyroscope capturing angular velocity in degrees per second at a rate of 200 Hz. Data collection was synchronized between the sensors and was triggered when either gyroscope signal passed a threshold of 4 degrees per second, recording for 199 frames.
2.3. Testing Protocol
Testing consisted of 10 stationary wrist shots and 10 stationary slap shots with 4 different sticks for a total of 80 shots. Stick A was the “baseline” stick, and Sticks B-D varied from Stick A in bending stiffness, blade pattern, or dynamic bending profile, respectively (
Table 2). The sticks were all uniform in length and were representative of those commonly used by players of similar caliber. The sticks were devoid of graphics to blind participants to their differences.
At the beginning of each trial, participants stood adjacent to the puck placed 5.13 m away from the net. Participants did not receive specific instructions with respect to their technique but were asked to shoot like they normally would in a game from a stationary position and to strive for maximum velocity and accuracy, aiming at a 0.3 m-diameter circular target suspended from the center of the net crossbar (
Figure 1).
Each participant performed the first 20 trials with the reference stick (Stick A), with subsequent stick exposure orders (i.e., BCD, CDB, DBC, etc.) assigned using the first ten orders from a permutation generator to approximate a crossover-balanced design. Shot exposure order (wrist–slap–wrist... or slap–wrist–slap...) alternated between participants. Between each block of 10 shots, participants received approximately 1 min of rest.
2.4. Data Processing
Data captured using the Vicon cameras were processed using Vicon Nexus 2.6 software. Processing consisted of marker data identification (“labelling”) and gap filling (interpolating missing marker positions). This “processed” data from the Nexus software were then imported into Visual3D software (Ver 5.01.23, C-Motion, Germantown, MD, USA) where data were filtered using a 4th-order Butterworth filter with a cut-off frequency of 25 Hz, and all 3D calculations and event detections were performed. All data were reflected to one body side to account for kinematic differences due to handedness using the biomechZoo toolbox [
17]. The terms “top” and “bottom” replaced “left” and “right” when identifying side-specific hand kinematic signals. Shot speed of each trial was calculated as peak puck velocity in the Y (towards the net) between puck contact/forward movement (START) and net entry (END) events for slap and wrist shots, respectively (
Table 3).
For the IMUs, only the Z axis was systematically aligned in the glove due to technical challenges related to consistency. The +Z axis was aligned in the glove in the direction of thumb extension with the +X and +Y orthogonal to this axis (
Figure 3). For this reason, only the resultant channels of the IMU’s accelerometer (linear acceleration in gravitational units) and gyroscope (angular velocity in degrees per second) were used for analysis. IMU data for both the left and right sensor were combined in the same file for each trial. Acceleration and gyroscope data were filtered with 4th-order lowpass Butterworth filter with a cut-off frequency of 20 Hz.
All trials were inspected for completeness, data quality, and event placement prior to the statistical analysis. Vicon trials were removed if certain events were unable to be detected in Visual3D; for example, if the trial ended prematurely or stick or puck markers had fallen off or went undetected by the Vicon system (n = 43).
Since IMU trials did not have events, trials from this dataset were only omitted if they ended before the shooting motion had finished (n = 44). Due to differences in the causes of trial omission, the Vicon and IMU datasets were analyzed separately. Despite the fact they are of similar size, the datasets should not be confused as identical.
2.5. Model Training and Validation
Three separate models were created for each channel to fit players for flex, blade pattern, and kick point. Slap and wrist shot data were analyzed separately (3 stick parameters × 4 channels × 2 shot type = 24 models). The algorithms devised in this study were attempting to classify the responses of players’ shooting performance to stick flex, blade pattern, and kick point independently while each IMU channel provided different hand kinematic data throughout the shooting motion. Thus, the purpose of developing different sets of flex, blade pattern, and kick point models was to evaluate which IMU channel was best for each shot type and stick parameter combination.
Separate models were trained and tested on their ability to classify (i.e., fit) shooters using four different channels from the in-glove IMUs:
Top hand resultant linear acceleration (Top_A);
Top hand resultant angular velocity (Top_G);
Bottom hand resultant linear acceleration (Bottom_A);
Bottom hand resultant angular velocity (Bottom_G).
Three stick parameters were controlled in this study (flex, blade pattern, kick point). To determine a subject’s true class on each stick parameter, the shot speed of the stick that varied along that parameter (Stick B, Stick C, or Stick D, respectively) was compared to that of the reference stick (Stick A). True class values of stick fit—for training the algorithms and evaluating model accuracy—were based on the stick with higher mean shot speed to the nearest whole meter per second (m/s). For example, if a subject shot at least 1 m/s faster with Stick A (95 flex) than Stick B (70 flex), this subject would be considered a “high flex responder”. Shot speed was chosen as the shooting performance metric to define true class based on its prevalence in the literature [
3,
4,
5,
7,
9,
18,
19] and its simplicity of measurement in various settings (e.g., using a radar gun).
The inputs of each model were reduced from 199 data points to the 14 to 18 principal components, or “features”, that explained 95% of the variability within the waveform data (
Table 4). In other words, principal components—rather than complete waveforms—were the features used to develop the algorithms. The features, in addition to true class values, were fed into MATLAB R2020a’s Machine Learning Toolbox, and prediction models were created using k-nearest neighbors (KNN) classification. Five-fold cross validation—such as the principal components—was used to improve the generalizability of the models.
For all models, standardized data, a Euclidean distance metric, equal distance weight, and a default misclassification cost matrix were used, and hyper-parametrization was disabled.
Model performance was evaluated primarily on classification accuracy (high being preferable) and secondarily on computation time (low being preferable) after the fifth fold of cross-validation was used to compare performance between models.
4. Discussion
Using in-glove IMU data, fine KNN machine learning models were capable of fitting players with their optimal flex, blade pattern, and kick point with 90–98% accuracy for slap shots and 93–97% accuracy for wrist shots. Perhaps more impressively, these algorithms were able to achieve these high levels of accuracy with a processing time of less than one second. Thus, it appears possible—using embedded sensors and fine KNN machine learning algorithms—to rapidly fit players for stick flex, blade, and kick point with high levels of accuracy.
Individual differences in optimal sticks for shot speed reported corroborate trends in previous hockey stick studies [
11] and those of other sporting implements [
20]. Anderson found three players using six different sticks of wood and composite constructions each shot fastest with a different stick.
More specifically, machine learning algorithms were able to identify individual differences in hand kinematic signals to predict optimal stick flex, blade pattern, and kick point based on shot velocity. This agrees with previous findings of Zane [
21] and Flemming [
22], who reported player coordinative strategies (or “shooting styles”) that appeared in both high- and low-caliber groups. It has been established that no two players shoot exactly the same [
22]; however, the methods used in this study were satisfactorily sensitive to the characteristics of hand kinematics relevant to stick fitting for the purpose of maximizing shot speed. Thus, further research is warranted to better understand how features of these kinematic profiles relate to stick fit and employ this technology to assist players in tuning the flex, blade pattern, and kick point that they use.
The small sample size (
n = 10) may have limited the statistical power of the analysis. A larger sample size (e.g.,
n = 40) of novel hockey players of differing ability levels would better permit the comparison of different machine learning algorithms in predicting hockey stick preferences in future studies [
14,
23]. Further, it is unknown how the findings of the present study apply to the larger population of hockey players, since it is not known how representative this sample is of the kinematic variability across different player demographics. For example, only experienced adult males participated in this study. Thus, the inclusion of female, youth, and less experienced athletes for the development of commercial hockey stick fitting applications is warranted since these groups represent large, growing segments of the global hockey stick market [
24].
Another limitation of this study was that the IMU data were limited to the resultant magnitude of the accelerometer and gyroscope data due to the lack of systematic alignment of the IMUs’ X and Y axes in the gloves. Nonetheless, the IMUs provided unencumbered, direct kinematic measurements of the hands, which makes them practical for application in stick fitting in retail hockey stores. More work is required to investigate the repeatability of these findings when accounting for IMU alignment.
Moreover, the current algorithm was delimited to the fitting of sticks based on shot velocity; however, shot accuracy and quickness may be of greater importance to a player depending on their position and style of play [
3]. Thus, it is suggested that future stick fitting research considers the contribution of such metrics to shooting performance at large. This could elucidate additional clusters of hockey shooters. IMU alignment, as mentioned above, would assist in ensuring the reliability of such algorithms.
An additional limitation of this study was that the sticks were not subjected to a battery of mechanical tests to understand the physical properties of sticks [
25]. Having such information would be interesting, particularly for understanding how such parameters relate to perceptions of shooting performance [
26,
27]. Further, understanding how perceptual and performance measures relate to dynamic player behaviors during shooting—such as grip width on the stick and stick bend—is of great interest.
In summary, these findings suggest that there are promising applications for the combination of embedded IMU sensors and machine learning algorithms in the fitting of ice hockey sticks due to the portability, accuracy, and processing speed of such systems. This technology could be used to recommend hockey stick parameters quickly, accurately, and scientifically in a format easily accessible to hockey players. In the future, standalone IMU systems could be used to further differentiate hockey players based on their shooting kinematics and provide more individualized fitting recommendations. Further research to investigate the repeatability of these findings within a larger, diverse, and representative group of hockey players is warranted.
5. Conclusions
Fine k-nearest neighbors machine learning models were capable of fitting players with their optimal flex, blade pattern, and kick point with 90–98% accuracy for slap shots and 93–97% accuracy for wrist shots using select principal components of in-glove IMU data. Perhaps more impressively, these algorithms were able to achieve these high levels of accuracy with a processing time of less than one second.
The above results demonstrate the potential of using embedded IMU sensors tracking hand kinematics and machine learning algorithms to accurately fit individuals for stick flex, blade pattern, and kick point. Similar research to this study should be conducted with a greater number of sticks with more subtle differences in flex, blade patterns, and kick points and a larger pool of hockey players of differing backgrounds to further validate the findings of this study. This study could be further supplemented through the capture of shooting performance and stick perception data in retail and on-ice settings using simplified objective measurement instruments (i.e., a radar gun).
Although it appears that players do not change their shooting style when using sticks of different flexes in the short run, it is not known how stable these gross kinematic patterns are and whether they would yield consistent values under test–retest conditions. Additionally, it is not yet known how habitual exposure to sticks of different flex, blade, and kick point properties affect shooting technique. Studies aimed at the repeat exposure and measurement of kinematics in response to sticks with different properties should be conducted.