Next Article in Journal
Review of Non-Invasive Fetal Electrocardiography Monitoring Techniques
Previous Article in Journal
A Review of Machine Learning and Deep Learning Methods for Person Detection, Tracking and Identification, and Face Recognition with Applications
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Development and Validation of an Argon Triple Point Apparatus with a Novel Automatic Pressure Control System

1
Laboratory for Process Measurement, Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, 10000 Zagreb, Croatia
2
Laboratory of Metrology and Quality Ljubljana, Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
*
Author to whom correspondence should be addressed.
Sensors 2025, 25(5), 1411; https://doi.org/10.3390/s25051411
Submission received: 30 December 2024 / Revised: 19 February 2025 / Accepted: 25 February 2025 / Published: 26 February 2025
(This article belongs to the Section Sensors Development)

Abstract

This paper describes the development and validation of an apparatus for the realization of the triple point of argon (83.8058 K), with a novel automatic pressure control system for the liquid nitrogen cryostat. The automatic pressure controller, together with custom-made software, was developed and tested in the Laboratory for Process Measurement at the Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb (FSB-LPM). Performance testing and characterization of the automatic pressure controller confirmed its suitability for precise and reliable control of gauge pressure in the cryostat. The characteristics and uncertainty of the measurement setup for the realization of the triple point of argon were validated through a bilateral hybrid comparison with the Laboratory of Metrology and Quality at the Faculty of Electrical Engineering, University of Ljubljana (MIRS/UL-FE/LMK). A long-stem quartz-sheathed standard platinum resistance thermometer was used as a transfer standard. The realizations of the International Temperature Scale (ITS-90) were compared in the subrange from the triple point of argon to the triple point of water. The comparison results show that resistance ratio (W) values determined by FSB-LPM at the fixed points of argon and mercury deviate from the MIRS/UL-FE/LMK values, within the determined combined uncertainty of the comparison.
Keywords: ITS-90; realization; fixed point; triple point; argon; pressure; control; cryostat; comparison ITS-90; realization; fixed point; triple point; argon; pressure; control; cryostat; comparison

Share and Cite

MDPI and ACS Style

Matas, I.; Grgec Bermanec, L.; Šestan, D.; Bojkovski, J.; Žužek, V. Development and Validation of an Argon Triple Point Apparatus with a Novel Automatic Pressure Control System. Sensors 2025, 25, 1411. https://doi.org/10.3390/s25051411

AMA Style

Matas I, Grgec Bermanec L, Šestan D, Bojkovski J, Žužek V. Development and Validation of an Argon Triple Point Apparatus with a Novel Automatic Pressure Control System. Sensors. 2025; 25(5):1411. https://doi.org/10.3390/s25051411

Chicago/Turabian Style

Matas, Ivan, Lovorka Grgec Bermanec, Danijel Šestan, Jovan Bojkovski, and Vincencij Žužek. 2025. "Development and Validation of an Argon Triple Point Apparatus with a Novel Automatic Pressure Control System" Sensors 25, no. 5: 1411. https://doi.org/10.3390/s25051411

APA Style

Matas, I., Grgec Bermanec, L., Šestan, D., Bojkovski, J., & Žužek, V. (2025). Development and Validation of an Argon Triple Point Apparatus with a Novel Automatic Pressure Control System. Sensors, 25(5), 1411. https://doi.org/10.3390/s25051411

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop