Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs
Abstract
:1. Introduction
2. Materials and Methods
2.1. Contact Test Protocol
2.2. Sampling and Analysis
- -
- Five days a week for 4 weeks, 300 mL were collected from the intradaily composite sample after mixing for the analysis of E. aerogenes or P. aeruginosa (100 mL in triplicate); 3 mL was also collected and analyzed for TAMC (1 mL in triplicate);
- -
- Four days a week for 4 weeks, 300 mL were collected from the interdaily water sample after mixing for the analysis of E. aerogenes or P. aeruginosa (100 mL in triplicate); 3 mL was also collected and analyzed for TAMC (1 mL in triplicate);
- -
- Once a week for 4 weeks, 300 mL were collected from the interweekly water sample after mixing for the analysis of E. aerogenes or P. aeruginosa (100 mL in triplicate); 3 mL was also collected and analyzed for TAMC (1 mL in triplicate);
- -
- Five days a week for 4 weeks, positive controls were tested for E. aerogenes or P. aeruginosa (1 mL in triplicate).
2.3. Tested Microorganisms
2.4. Microbiological Methods
2.5. Data Analysis
3. Results
3.1. Enterobacter Aerogenes
3.2. Pseudomonas aeruginosa
3.3. Total Aerobic Microbial Count at Room Temperature
4. Discussion
5. Conclusions
Author Contributions
Funding
Conflicts of Interest
References
- Hug, M.; Xavie, G.; Domene, E.; Sauri, D. Tap water, bottled water or in-home water treatment. Systems: Insights on household perceptions and choices. Water 2020, 12, 1310. [Google Scholar] [CrossRef]
- French Agency for Food, Environmental and Occupational Health & Safety (ANSES). Opinion of the French Agency for Food, Environmental and Occupational Health & Safety on the Assessment of the Safety and Effectiveness of Water Filter Jugs; Opinion Request No 2015-SA-0083; French Agency for Food, Environmental and Occupational Health & Safety (ANSES): Maisons-Alfort, France, 2016. [Google Scholar]
- Information Note no. 2014-XXX (Communicable under the Act of 17 July 1978). Review of the TN 35EA Investigation Undertaken in the Fourth Quarter of 2012 Dealing with Domestic Household Treatment Devices: Water Filter Jugs and Permanent Filtration Facilities; 27 March 2014; Directorate General for Competition Policy, Consumer affairs and Fraud Control (DGCCRF)—Ministry of Economy and Finance France: Paris, France, 2014.
- Doria, M.F. Factors influencing public perception of drinking water quality. Water Policy 2010, 12, 1–19. [Google Scholar] [CrossRef]
- European Union. Council Directive 98/83/EC. On the Quality of Water Intended for Human Consumption. Off. J. Eur. Communities 1998, 330, 32–54. [Google Scholar]
- European Union. Commission Directive (EU) 2015/1787 of 6 October 2015 amending Annexes II and III to Council Directive 98/83/EC on the quality of water intended for human consumption. Off. J. Eur. Communities 2015, 260, 6–17. [Google Scholar]
- Disposizioni Tecniche Concernenti Apparecchiature Finalizzate al Trattamento dell’Acqua Destinata al Consumo Umano [Technical Provisions Concerning Equipment for the Treatment of Water Intended for Human Consumption]; Italian Decree of the Ministry of Health 25/2012; Gazzetta Ufficiale n. 69 del 22-3-2012; Ministry of Health: Rome, Italy, 2012.
- World Health Organization (WHO). Guidelines for Drinking Water Quality, 4th ed.; World Health Organization (WHO): Geneva, Switzerland, 2011; 541p. Available online: http://whqlibdoc.who.int/publications/2011/9789241548151eng.pdf (accessed on 20 September 2020).
- Lautenschlager, K.; Hwang, C.; Liu, W.T.; Boon, N.; Köster, O.; Vrouwenvelder, H.; Egli, T.; Hammes, F. A microbiology-based multi-parametric approach towards assessing biological stability in drinking water distribution networks. Water Res. 2013, 47, 3015–3025. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Nescerecka, A.; Juhna, T.; Hammes, F. Identifying the underlying causes of biological instability in a full-scale drinking water supply system. Water Res. 2018, 135, 11–21. [Google Scholar] [CrossRef]
- Bartram, J.; Cotruvo, J.; Exner, M.; Fricker, C.; Glasmacher, A. Heterotrophic Plate Counts and Drinking-Water Safety: The Significance of HPCs for Water Quality and Human Health; WHO Emerging Issues in Water and Infectious Disease Series; IWA Publishing: London, UK, 2003. [Google Scholar] [CrossRef]
- Hambsch, B.; Sacre, C.; Wagner, I. Heterotrophic plate count and consumer’s health under special consideration of water softeners. Int. J. Food Microbiol. 2004, 92, 365–373. [Google Scholar] [CrossRef]
- Chang, C.Y. Surface sensing for biofilm formation in Pseudomonas aeruginosa. Front. Microbiol. 2017, 8, 2671. [Google Scholar] [CrossRef]
- Douterelo, I.; Sharpe, R.L.; Boxall, J.B. Influence of hydraulic regimes on bacterial community structure and composition in an experimental drinking water distribution system. Water Res. 2013, 47, 503–516. [Google Scholar] [CrossRef]
- Kilb, B.; Lange, B.; Schaule, G.; Flemming, H.C.; Wingender, J. Contamination of drinking water by coliforms from biofilms grown on rubber-coated valves. Int. J. Hyg. Environ. Health 2003, 206, 563–573. [Google Scholar] [CrossRef]
- Ashbolt, N.J.; Grabow, W.O.K.; Snozzi, M. Indicators of microbial water quality. In Water Quality—Guidelines, Standards and Health. Assessment of Risk and Risk Management for Water-Related Infectious Disease; Fewtrell, L., Bartram, J., Eds.; World Health Organization: Geneva, Switzerland, 2001; pp. 289–316. [Google Scholar]
- Bonadonna, L.; Ottaviani, M. Metodi Analitici di Riferimento per le Acque Destinate al Consumo Umano ai Sensi del DL.vo 31/2001. Metodi Microbiologici. Rapporti ISTISAN 07/5; Istituto Superiore di Sanità: Roma, Italia, 2007. [Google Scholar]
- Garboś, S.; Swięcicka, D. Silver migration from silver-modified activated carbon applied as a water filtration medium in classic cartridges of jug filter systems. Food Addit. Contam. Part A Chem. Anal. Control. Expo. Risk Assess. 2012, 29, 1810–1819. [Google Scholar] [CrossRef]
- Garboś, S.; Swiecicka, D. Human exposure to silver released from silver-modified activated carbon applied in the new type of jug filter systems. Rocz. Panstw. Zakl. Hig. 2013, 64, 1–6. [Google Scholar]
- RASFF (Rapid Alert System for Food and Feed). Available online: https://webgate.ec.europa.eu/rasff-window/portal/?event=SearchForm&cleanSearch=1# (accessed on 20 September 2020).
- RAPEX (Rapid Alert System for Dangerous Non-Food Products). Available online: http://ec.europa.eu/consumers/safety/rapex/alerts/main/index.cfm?event=main.search (accessed on 20 September 2020).
- Water quality—Enumeration of Escherichia Coli and Coliform Bacteria—Part 2: Most Probable Number Method; ISO 9308-2:2012; International Organization for Standardization (ISO): Geneva, Switzerland, 2012.
- Water Quality—Detection and Enumeration of Pseudomonas Aeruginosa—Part 2: Most Probable Number Method; ISO 16266-2:2018; International Organization for Standardization (ISO): Geneva, Switzerland, 2018.
- Water Quality—Enumeration of Culturable Micro-Organisms—Colony Count by Inoculation in a Nutrient Agar Culture Medium; ISO 6222:1999; International Organization for Standardization (ISO): Geneva, Switzerland, 1999.
- Daschner, F.D.; Rüden, H.; Simon, R.; Clotten, J. Microbiological contamination of drinking water in a commercial household water filter system. Eur. J. Clin. Microbiol. Infect. Dis. 1996, 15, 233–237. [Google Scholar] [CrossRef] [PubMed]
- Drinking Water Inspectorate. Assessment of the Effects of Jug Water Filters on the Quality of Public Water Supplies; Report n. DWI 6049/2; Drinking Water Inspectorate (DWI): England, UK, 2003. Available online: http://dwi.defra.gov.uk/research/completed-research/reports/DWI70-2-147.pdf (accessed on 20 September 2020).
- Camper, A.K.; LeChevallier, M.W.; Broadaway, S.C.; McFeters, G.A. Bacteria associated with granular activated carbon particles in drinking water. Appl. Environ. Microbiol. 1986, 52, 434–438. [Google Scholar] [CrossRef] [Green Version]
- Hwang, M.G.; Katayama, H.; Ohgaki, S. Inactivation of Legionella pneumophila and Pseudomonas aeruginosa: Evaluation of the bactericidal ability of silver cations. Water Res. 2007, 41, 4097–4104. [Google Scholar] [CrossRef]
- Huang, H.I.; Shih, H.Y.; Lee, C.M.; Yang, T.C.; Lay, J.J.; Lin, Y.E. In vitro efficacy of copper and silver ions in eradicating Pseudomonas aeruginosa, Stenotrophomonas maltophila and Acinetobacter baumannii: Implications for on-site disinfection for hospital infection control. Water Res. 2008, 42, 73–80. [Google Scholar] [CrossRef]
- Silvestry-Rodriguez, N.; Bright, K.R.; Uhlmann, D.R.; Slack, D.C.; Gerba, C.P. Inactivation of Pseudomonas aeruginosa and Aeromonas hydrophila by silver in tap water. J. Environ. Sci. Health A 2007, 42, 1579–1584. [Google Scholar] [CrossRef]
- Veschetti, E. Results of a recent survey of the use of jug water filters. In Proceedings of the 33rd ENDWARE Meeting, Gibraltar, 21–22 May 2013. [Google Scholar]
- Wingender, J.; Flemming, H.C. Biofilms in drinking water and their role as reservoir for pathogens. Int. J. Hyg. Environ. Health 2011, 214, 417–423. [Google Scholar] [CrossRef]
- Douterelo, I.; Jackson, M.; Solomon, C.; Boxall, J. Microbial analysis of in situ biofilm formation in drinking water distribution systems: Implications for monitoring and control of drinking water quality. Appl. Microbiol. Biotechnol. 2016, 100, 3301–3311. [Google Scholar] [CrossRef] [Green Version]
- Mena, K.D.; Gerba, C.P. Risk assessment of Pseudomonas aeruginosa in water. Rev. Environ. Contam. Toxicol. 2009, 201, 71–115. [Google Scholar] [CrossRef]
- Buck, A.C.; Cooke, E.M. The fate of ingested Pseudomonas aeruginosa in normal persons. J. Med. Microbiol. 1969, 2, 521–525. [Google Scholar] [CrossRef]
- Al-Hiyasat, A.S.; Ma’ayeh, S.Y.; Hindiyeh, M.Y.; Khader, Y.S. The presence of Pseudomonas aeruginosa in the dental unit waterline systems of teaching clinics Intern. J. Dent. Hyg. 2007, 5, 36–44. [Google Scholar] [CrossRef]
- Leclerc, H.; Moreau, A. Microbiological safety of natural mineral water. FEMS Microbiol. Rev. 2002, 26, 207–222. [Google Scholar] [CrossRef]
- Schwartz, T.; Hoffmann, S.; Obst, U. Formation and bacterial composition of young, natural biofilms obtained from public bank-filtered drinking water systems. Water Res. 1998, 32, 2787–2797. [Google Scholar] [CrossRef]
- Tobin, R.S.; Smith, D.K.; Lindsay, J.A. Effects of activated carbon and bacteriostatic filters on microbiological quality of drinking water. Appl. Environ. Microbiol. 1981, 41, 646–651. [Google Scholar] [CrossRef] [Green Version]
E. aerogenes Pitcher (n.) | Interdaily Stagnation (16 Per Pitcher) * | Interweekly Stagnation (4 Per Pitcher) ** |
---|---|---|
Mean ± SD (min–max) MPN/100 mL | Mean ± SD (min–max) MPN/100 mL | |
1 | 8.9 ± 2.1 × 101 | 0 |
(0.0–7.8 × 101) | (0.0–0.0) | |
2 | 6.0 ± 1.2 × 101 | 0 |
(0.0–4.3 × 101) | (0.0–0.0) | |
3 | 4.4 ± 7.9 | 2.2 ± 4.3 |
(0.0–2.9 × 101) | (0.0–8.6) | |
4 | 4.6 × 101 ± 8.1 × 101 | 0 |
(0.0–2.0 × 102) | (0.0–0.0) | |
5 | 1.8 × 101 ± 3.9 × 101 | 0 |
(0.0–1.3 × 102) | (0.0–0.0) | |
6 | 1.2 × 101 ± 3.1 × 101 | 0 |
(0.0–1.0 × 102) | (0.0–0.0) | |
7 | 3.3 × 101 ± 6.3 × 101 | 0 |
0.0–2.0 × 102 | (0.0–0.0) | |
8 | 1.6 × 101 ± 3.4 × 101 | 0 |
0.0–1.0 × 102 | (0.0–0.0) | |
9 | 7.1 ± 1.5 × 101 | 0 |
0.0–4.3 × 101 | (0.0–0.0) |
P. aeruginosa Pitcher (n.) | Interdaily Stagnation (16 Per Pitcher) * | Interweekly Stagnation (4 Per Pitcher) ** |
---|---|---|
Mean ± SD (min–max) MPN/100 mL | Mean ± SD (min–max) MPN/100 mL | |
1 | 4.4 × 103 ± 4.4 × 103 | 5.9 × 103 ± 3.5 × 103 |
(6.4–1.6 × 104) | (0.0–9.1 × 103) | |
2 | 5.3 × 105 ± 7.0 × 105 | 2.1 × 106 ± 2.6 × 106 |
(0.0–2.2 × 106) | (0.0–5.6 × 106) | |
3 | 2.6 × 101 ± 4.9 × 101 | 1.8 ± 2.5 |
(0.0–2.0 × 102) | (0.0–5.3) | |
4 | 5.5 × 101 ± 9.5 × 101 | 5.0 × 102 ± 1.0 × 103 |
(0.0–3.3 × 102) | (0.0–2.0 × 103) | |
5 | 3.2 × 101 ± 5.3 × 101 | 4.2 ± 8.4 |
(0.0–1.4 × 102) | (0.0–1.7 × 101) | |
6 | 5.6 × 101 ± 7.6 × 101 | 8.4 ± 1.3 × 101 |
(0.0–2.0 × 102) | (0.0–2.7 × 101) | |
7 | 8.9 ± 1.7 × 101 | 0 |
0.0–5.3 × 101 | (0.0–0.0) | |
8 | 1.0 × 101 ± 2.6 × 101 | 0 |
0.0–1.0 × 102 | (0.0–0.0) | |
9 | 6.7 ± 1.2 × 101 | 0 |
0.0–3.2 × 101 | (0.0–0.0) |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Briancesco, R.; Paduano, S.; Semproni, M.; Vitanza, L.; Bonadonna, L. Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs. Int. J. Environ. Res. Public Health 2020, 17, 8263. https://doi.org/10.3390/ijerph17218263
Briancesco R, Paduano S, Semproni M, Vitanza L, Bonadonna L. Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs. International Journal of Environmental Research and Public Health. 2020; 17(21):8263. https://doi.org/10.3390/ijerph17218263
Chicago/Turabian StyleBriancesco, Rossella, Stefania Paduano, Maurizio Semproni, Luca Vitanza, and Lucia Bonadonna. 2020. "Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs" International Journal of Environmental Research and Public Health 17, no. 21: 8263. https://doi.org/10.3390/ijerph17218263
APA StyleBriancesco, R., Paduano, S., Semproni, M., Vitanza, L., & Bonadonna, L. (2020). Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs. International Journal of Environmental Research and Public Health, 17(21), 8263. https://doi.org/10.3390/ijerph17218263