Article

Batch and Fixed-Bed Column Studies on Palladium Recovery from Acidic Solution by Modified MgSiO3

1
Faculty of Industrial Chemistry and Environmental Engineering, Politehnica University Timisoara, 300223 Timisoara, Romania
2
Research Institute for Renewable Energy, Politehnica University Timisoara, 138 Musicescu Street, 300774 Timisoara, Romania
*
Authors to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2020, 17(24), 9500; https://doi.org/10.3390/ijerph17249500
Submission received: 18 November 2020 / Revised: 12 December 2020 / Accepted: 16 December 2020 / Published: 18 December 2020
(This article belongs to the Section Environmental Science and Engineering)

Abstract

:
Effective recovery of palladium ions from acidic waste solutions is important due to palladium’s intensive usage as a catalyst for different industrial processes and to the high price paid for its production from natural resources. In this paper, we test the ability of a new adsorbent, MgSiO3 functionalized by impregnation with DL-cysteine (cys), for palladium ion recovery from waste solutions. The Brunauer–Emmett–Teller (BET) surface area analysis, Barrett–Joyner–Halenda (BJH) pore size and volume analysis, scanning electron microscopy (SEM), energy dispersive X-ray (EDX) spectroscopy and Fourier-Transformed Infrared (FTIR) spectroscopy have been performed to characterize this material. Firstly, the maximum adsorption capacity of the new obtained material, MgSiO3-cys, in batch, was studied. To establish the adsorption mechanism, the obtained experimental data were fitted using the Langmuir, Freundlich and Sips adsorption isotherms. Studies on the adsorption of palladium ions on the synthesized material were performed in a dynamic regime, in a fixed-bed column. The Pd(II) recovery mechanism in the dynamic column regime was established based on Bohart–Adams, Yoon–Nelson, Thomas, and Clark models. The obtained equilibrium adsorption capacity was 9.3 (mg g−1) in static regime (batch) and 3 (mg g−1) in dynamic regime (column). The models that best describe the Pd(II) recovery process for batch and column adsorption are Sips and Clark, respectively.

1. Introduction

The noble metals platinum, palladium and rhodium have a wide application range based on their distinct physical and chemical properties [1,2,3,4,5]. One of the first historical uses of the precious metals was as currency, internationally recognized under ISO 4217. Palladium and its alloys are currently used by the telecommunication and automotive industries (as catalytic converters), the metallurgy and chemical industries, for jewelry manufacturing and in the medical field (dental alloy production) [5,6,7,8,9].
Its growing popularity led, in 2010, to official recognition as the fourth most precious metal, after gold, silver and platinum, a statute that requires the marking of each jewel. White gold contains variable amounts of palladium (up to 20%); furthermore, dental alloys can contain up to 10% palladium [5,10,11,12,13,14,15].
Due to its increased used, palladium has become an important contact allergen, with palladium-positive patch-tests being reported by different countries—from 2% in Northern Ireland to 13% in Israel. The main aspects of palladium allergy are contact dermatitis, rash for lichen planes, stomatitis, and mouth burns [16].
Because natural platinum resources are limited, the recovery of platinum-group metals is a challenge of great importance. The two main classes of recyclable precious metal wastes are (i) precious metals including tableware, jewelry, coins, electronic waste, and spent catalysts, and (ii) secondary products of recovery/processing/use of precious metals and, namely, waste: sludge, anodic sludge, ash, filters, refractory materials, crucibles, photographic films, and resins [5].
Palladium compounds are toxic and carcinogenic for humans. Palladium is easily accumulated into plants, transported through their roots, and, finally, along the food chain [17]. Excessive exposure to palladium has adverse effects on human health, such as skin and eye irritation, substantial DNA and cell mitochondrial degradation, and deterioration and inhibition of hydroxyl radicals associated with enzymatic activity [18]. As environmental issues related to palladium contamination continue to grow, finding advantageous extracting alternatives becomes very important. Some of the analytical techniques used for palladium ion recovery by separation and preconcentration are coprecipitation, solvent extraction, electro-deposition, or membrane filtration [19,20,21,22,23,24,25].
These techniques have some major disadvantages such as lack of sensitivity and selectivity, high cost, and high consumption of toxic organic solvents [26,27,28,29]. Recently, a new separation technique has emerged, having many advantages over traditional extraction methods: high enrichment factor, better separation, selectivity and high efficiency, ease of recovery and reuse, low cost due to the low consumption of organic reagents and solvents, and, most importantly, environmentally friendly. This method consists of using a preconcentration of the metal ion of new materials obtained by functionalization of chemically inert supports with various pendant groups. Some of the advantages of these new materials are high chemical and thermal stability, fast availability, economic viability, and easy and robust surface immobilization. The materials most commonly used as supports are commercial polymeric resins [30,31,32], resins such as Dowex 1-X10 [33], Bio-Rad AG1-8x [34], Dowex 1-X8 and Amberlite IRN -78 [35,36,37,38,39], Amberlite IRA-958, Lewatit MP-500 A, and Purolliet A-850 [40,41], natural polymers [42], inorganic silicone compounds [43], magnesium silicate [44,45], and ionic liquids crown ethers [46].
Selection of the sorbent material is a complex decision, the choice being influenced by the palladium form in the considered waste and many other factors. The absorbent materials technology can be efficient at the laboratory scale, but could be a failure at industrial level. Thus, the choice of sorbent material in close correlation with treatment technology for liquid acid waste is very important.
Adsorption is an advanced method, efficient and with high potential for metal ion removal from aqueous solutions. Therefore, it is important to develop new materials having advanced sorbent properties. Materials can be improved by functionalization of the solid support with an extractant containing certain groups designed to improve the sorbent properties of the support. Organic compounds with structural N, P, or S pendant groups can be used as extractors for functionalization of the support [44,47].
Therefore, new chemical modification methods of the inorganic or organic supports have been developed by functionalization with different extractants.
Common techniques at present include the wet method, the dry method, the adding modifiers method, and the dynamic column method, which has the following advantages: a short functionalization time and an increased effectiveness of the adsorption process [48,49,50,51,52,53].
In order to apply these methods, some restrictions must be considered—the extractant must be liquid or be kept in a liquid state by the addition of solvent; the extractant and solvent must have a minimum solubility; the support must be prepared for impregnation; and the functionalization method must not alter the properties of the extractant or support [51].
The purpose of this study was to develop an ecological strategy for Pd(II) recovery using (florisil) MgSiO3 functionalized by impregnation with DL-cysteine (cys) [49]. This new material has -SH, -NH2, and -COOH pendant groups derived from the amino acid DL-cysteine [54,55].
The first objective was to test the new MgSiO3 cys material’s ability to recover palladium ions from waste solutions by adsorption. The second goal of this research was to compare the static adsorption process with the dynamic one.

2. Materials and Methods

2.1. Adsorbent Synthesis and Characterization

Functionalized MgSiO3 using DL-cysteine (DL-cysteine-hydrochloride monohydrate 99.0%, Fluka, Buchs, Switzerland) as extractant was obtained using 0.1 g of DL-cysteine. This amount of extractant was dissolved in 25 mL of deionized water. The obtained solution was mixed with 1 g of support (MgSiO3, 60–100 mesh, Merck, Darmstadt, Germany), corresponding to a ratio support: extractant of 1:0.1 and they were brought into contact for 24 h in stand-by (SIR, solvent impregnated resin—dry method) [49,51]. After that, the obtained material was dried in the oven (Pol-Eko SLW 53 STD, POL-EKO-APARATURA, Wodzisław Śląski, Poland) for 24 h at 323 K. The appearance of the adsorbent material can be seen in Figure 1.
The specific surface area, cumulative pore volume, and pore size of the adsorbent material were measured with a Micromeritics ASAP 2020 instrument (Brunauer–Emmett–Teller, BET, surface area analysis and Barrett–Joyner–Halenda, BJH, pore size and volume analysis, at liquid nitrogen temperature, −196 °C) from Micromeritics Instrument, Norcross, GA, USA. The point of zero charge (pHPZC) and density were determined using the solid addition method and pycnometer method, respectively. Furthermore, the adsorbent was analyzed by scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy, using the FEI Quanta FEG 250 instrument (FEI, Eindhoven, The Netherlands), and Fourier-Transformed Infrared (FTIR) spectroscopy using a Bruker Platinum ATR-QL Diamond apparatus (Bruker Optik GmbH, Ettlingen, Germany) in the range of 4000–400 cm−1.

2.2. Batch Adsorption Experiments

The effect of the initial concentration of Pd(II) upon the adsorption capacity of the materials was studied using Pd(II) solutions of different concentrations (5, 10, 20, 30, 40, and 50 mg L−1), prepared by the appropriate dilution of a stock solution of palladium (II) chloride (5 wt% in 10 wt% HCl, Sigma-Aldrich, St. Louis, MO, USA). Adsorptions were carried out at pH = 2 for one hour at 298 K. The equilibrium concentration was determined using thermostatic Julabo SW23 water bath and shaken at a rotation speed of 200 rpm. The adsorption mechanism was established by modeling the experiment using three specific isotherms in non-linear form: Langmuir, Freundlich and Sips, according to equations used in scientific literature [56,57,58,59].
Langmuir   q e = q m K L C e 1 + K L C e
Freundlich   q e = K F C e 1 / n F
Sips   q e = q m K S C e 1 / n S 1 + K S C e 1 / n S
where qe is the maximum absorption capacity (mg g−1), qm is maximum adsorption capacity (mg g−1), KL is the Langmuir constant, Ce is the equilibrium concentration of Pd(II) in solution (mg L−1), KF is the Freundlich constant, 1/nF is the heterogeneity factor, KS is Sips constant, and 1/nS is the Sips model exponent.
Three independent replicates were performed for each batch adsorption experiment.

2.3. Column Adsorption Experiments

The obtained sorbent, MgSiO3 functionalized using DL-cysteine (MgSiO3- cys), was used for dynamic studies in a fixed-bed column. Pd(II) solutions’ initial concentration was 60 (mg L−1), prepared using appropriate dilution of a stock solution of palladium (II) chloride (5 wt% in 10 wt% HCl, Sigma-Aldrich, St. Louis, MO, USA).
The experimental setup was made using a glass column (diameter 20 mm and height 300 mm) loaded with three different amounts of adsorbent material (10, 5, and 3 g), corresponding to three layers’ heights (70, 35, and 21 mm, respectively) (Figure 2). The Pd(II) solution was transferred in the experimental column using a peristaltic pump (Heidolph SP quick, Heidolph Instruments, Schwabach, Germany) at a flow rate of 7 (mL min−1). The studies were made using samples sequences of 25 mL. The retention times of the solution in the adsorption column, corresponding to the amounts of adsorbent mentioned above, were approximately 3, 1.5, and 1 min, respectively. The residual concentration of Pd(II) was measured using an atomic absorption spectrometer type Varian AAS 280 FS (Varian Inc., Mulgrave, Australia).
For each adsorption column experiment, there were three independent replicates.
The column adsorption mechanism was established using four specific models: Bohart–Adams, Thomas, Yoon–Nelson, and Clark (linear form), according to equations described elsewhere [60,61,62,63,64,65].
Bohart Adams   ln ( C t C 0 ) = k B A C 0 t k B A N 0 Z F
Thomas   ln ( C 0 C t 1 ) = k T h q T h m Q k T h C 0 t
Yoon Nelson   ln ( C t C 0 C t ) = k Y N t τ k Y N
Clark   ln ( ( C t C 0 C t ) n 1 ) = ln A r t
where C0 is the influent concentration (mg L−1); Ct is the solution concentration at time t in the effluent (mg L−1); t is time (min); kBA is the kinetic constant of the Bohart–Adam model (L mg−1 min−1); F is the linear velocity calculated by dividing the flow rate by the column section area; Z is the bed depth of column (cm); N0 is the saturation concentration (mg L−1); kTh is the Thomas rate constant (L min−1 mg−1); qTh is the equilibrium compound uptake per g of the resin (mg g−1); m is the mass of sorbent resin (g); Q is the flow rate (mL min−1); kYN is the rate constant (min−1); τ is the time required for 50% adsorbate breakthrough (min); n is the Freundlich constant determined experimentally in batch; r is the Clark model constant (min−1); and A is the Clark model constant.

3. Results and Discussion

3.1. Characterization of the MgSiO3-Cys

BET analysis showed that the specific surface area was SBET = 166 (m2 g−1). The average pore size and cumulative pore volume calculated using BJH method were 25.24 nm and 0.43 (cm3 g−1), respectively. The value of pHPZC was six and the density was about 4 (g cm−3).
Figure 3 shows the main morphological changes of the surface of the adsorbent material that appeared after impregnation. The presence of functional groups in MgSiO3-cys was investigated using energy dispersive X-ray spectroscopy (EDX) (Figure 4). The EDX spectra of MgSiO3-cys show both magnesium silicate peaks (O, Mg, Si) and N, S, and C characteristic peaks, confirming the presence of specific peaks for functionalized sorbent.
Infrared spectroscopy (FTIR) was used to confirm the MgSiO3 functionalization. The FTIR spectra for commercial magnesium silicate together with functionalized MgSiO3-cys are presented in Figure 5. Magnesium silicate-specific peaks can be observed on both spectra: a large peak at 1052 cm−1 and another peak at 600 cm−1, corresponding to Si–O stretching vibrations, and the peak at 800 cm−1, assigned to Si–O–Si bending vibrations. The MgSiO3 spectrum show a band at ~3500 cm−1 and a peak at 1637 cm−1, specific to the –OH bond from H2O molecules.
The FTIR spectrum of magnesium silicate functionalized with DL-cysteine shows specific peaks for the –SH bond at ~2620 cm−1, the –NH2 bond at ~2245 cm−1, the –COOH bond at ~1325 cm−1. The intensities of those peaks are lower compared to those of MgSiO3 due to the small cysteine amount used in the functionalization process. This process leads to an attenuation of MgSiO3 specific vibrations.

3.2. Equilibrium Adsorption Studies. Adsorption Isotherms

The maximum adsorption capacity of the MgSiO3-cys material was determined based on adsorption experiment data using three isotherm models: Langmuir, Freundlich, and Sips [66]. The equilibrium adsorption capacity was determined by monitoring the dependence of materials’ adsorption capacity vs. initial Pd(II) concentration, illustrated in Figure 6.
Augmentation of the initial Pd(II) solution concentration led to an increase in the adsorption capacity up to an approximately constant value. The highest Pd(II) adsorption capacity (qm) on DL-cysteine functionalized magnesium silicate, for a steady state concentration of 40 (mg L−1), was 9.23 (mg g−1).
Figure 7 shows the equilibrium isotherms for the studied material. The parameters of the isotherm models for palladium ion adsorption on the studied functionalized material are presented in Table 1.
The existing literature data [67] suggest that most metallic ion adsorption processes on the MgSiO3-cys material obtained by chemical modification are multilayer processes and the surface is heterogeneous. At the same time, the adsorption mechanism is controlled by chemisorption processes due to the strong chelation between metal ions and OH groups or free electron pairs of S and/or N—containing pendant groups present on the surface of the chemical functionalized material.
Using the Sips isotherm to model the obtained experimental data leads to a parameter 1/ns value deviated from unity, suggesting the heterogeneity of the adsorbent surface [68]. Regardless of the extractant used for functionalization, the Sips model better describes the adsorption process, reflected by the highest correlation coefficient (R2) values. In the case of Pd(III) adsorbed on DL-cysteine functionalized magnesium silicate, the correlation coefficient of the Sips isotherm, R2 = 0.9953, is higher than those obtained using the Langmuir and Freundlich adsorption isotherms. In addition, the calculated equilibrium adsorption capacity of the Sips model (9.62 mg g−1) was consistent with that obtained experimentally (9.23 mg g−1).

3.3. Bed Height Column (BHC) Influence on the Pd(II) Breakthrough Curves

An important parameter in the sorption process is the bed depth. Pd(II) retention in a fixed-bed column depends, among other factors, on the sorbent quantity reflected by the bed depth of the column works. Three different heights of the MgSiO3-cys sorbent filling the fixed-bed column were used in the experiments: 2.1, 3.5, and 7.0 cm.
According to Figure 8, the column adsorption process is highlighted by establishing breakthrough curves, which represent the variation of the ratio between the residual concentration of Pd(II) and its initial concentration (Crez/C0), depending on the volume of effluent passed through the column, for three distinct amounts of material. Volumes of Pd(II) of 60 (mg L−1) concentration were varied between 1500 and 3000 mL, depending on the amount of adsorbent material in the column.
The mass transfer area is the active surface of the bed of adsorbent material where the adsorption of Pd(II) ions takes place [65]. The first part of the column adsorption process takes place rapidly, through the adsorption of Pd(II) on the surface of the material, called the primary adsorption zone. This is why, at the beginning, the collected samples do not contain Pd(II) ions. The second part of the adsorption process is slower and is characterized by the adsorption of Pd(II) ions on the adsorbent material, achieving mass transfer. The adsorption process is complete, the concentration of Pd(II) ions varies from 60 to 0 (mg L−1), and the saturation of the material is total.
For the three different bed depths used, as the bed depth increases (from 2.1 at 7 cm), the breakthrough point increases (from 100 to 325 min). A rational explanation of this behavior is that with increasing column sorbent height a greater number of binding sites become available and the quantity of the Pd(II) removed increases accordingly [69].
A higher BHC leads to a longer contact time between the waste solution and the MgSiO3-cys sorbent (from about 1 min to 3 min), having a positive influence on Pd(II) adsorption.
Figure 8 shows an alteration of the steep concave shape to flat concave shape curves as BHC increases, which leads to an enlargement of the mass transfer area [70,71,72]. However, too high a layer of adsorbent material in the column is not recommended as it increases the flow resistance [73].

3.4. Modeling for Adsorption Behaviors of Pd(II) on MgSiO3-Cys

Various practical parameters such as sorbent capacity, contact time between adsorbent and adsorbed, column operating life span, regeneration time, and prediction of the time necessarily have a significant influence upon the operation of the column. Knowing these parameters is important to model the adsorption process in a fixed-bed column.
The four models tested (Bohart–Adams, Yoon–Nelson, Thomas, and Clark) provide detailed conclusions about the process mechanism. The adsorption column is subjected to axial dispersion, external film strength, and intraparticle diffusion resistance [74].
The Bohart–Adams model is used for one-component systems and provides information on the saturation concentration of the material. This model characterizes the beginning of the column penetration, gives information about the adsorbent material used, and shows the maximum concentration at which the column is instantly broken through [60]. The Yoon–Nelson model is used to model a one-component system and provides information about the time by which half of the column is broken through. It is a purely theoretical model which does not focus on the properties of the adsorbent, the type of adsorbent, or the physical characteristics of the fixed bed [74]. The Thomas model provides information on the maximum solid phase concentration of the adsorbent and on the rate constant [62], while the Clark model describes, very well, the dynamic adsorption process [74].

3.4.1. Bohart–Adams Model

Figure 9 illustrates the influence of sorbent dose (10, 5, and 3 g) corresponding to the three previously mentioned BHCs (7, 3.5, and 2.1 cm) on the ln (Ct/C0) vs. time curves. The graphic shows a direct influence of the sorbent amount upon maximum adsorption capacity, N0, and the kinetic constant, kBA, which indicates that, kinetically, the process is controlled by the mass transfer in the first part of the breakthrough process. The calculated regression coefficients have relatively low values (between 0.9717 and 0.9755); therefore, one can assume that the model is not the most suitable to describe the Pd(II) adsorption mechanism on MgSiO3-cys in a dynamic regime.

3.4.2. Thomas Model

Figure 10 shows the influence of sorbent dose (10, 5, and 3 g) upon the ln[(C0/Ct) − 1] vs. time curves. The figure illustrates that a higher sorbent amount leads to a decrease in the Thomas rate constant kTh. The reason for this behavior is the adsorption driving force given by the difference between the Pd(II) concentration in the sorbent and in the solution [75,76,77,78]. The determination coefficient R2 values (between 0.9704 and 0.9961) indicated positive correlation, but we cannot assume that this model is best fitted for the adsorption mechanism. The adsorption capacity qTh and the kinetic constant are presented in Table 2.

3.4.3. Yoon–Nelson Model

Figure 11 illustrates the relationship of ln[Ct/(C0Ct)] vs. time for the three sorbent doses. Increasing the sorbent mass leads to an increase in the breakthrough time and also in the kYN constant, as it is presented in Table 2. The determination coefficient R2 ranged between 0.9722 and 0.9941 but we cannot assume that it best describes the adsorption process.

3.4.4. Clark Model

The relationship ln[(C0/Ct)n−1 − 1] vs. time for all adsorbent doses studied is shown in Figure 12, where n is the Freundlich constant, determined experimentally in batch section. The value of this parameter was 1.81. The high values of the determination coefficient R2 (between 0.9881 and 0.9973) certify that the Clark model best describes the adsorption in a fixed-bed column. The value of r and A parameters are presented in Table 2.
Table 3 provides a comparison between the DL-cysteine functionalized magnesium silicate obtained in this study and other commonly used sorbents for Pd(II) removal in batch systems. The equilibrium adsorption capacity value is comparable to or even higher than those obtained in previous studies using various adsorbent materials. This behavior is based on the presence of the -SH and -NH2 groups in functionalized material structures, suggesting the surface adsorption of Pd(II) by free electrons or by creating hydrogen bridges.
In addition, the experimental conditions in which the adsorption studies were performed, for each material, are highlighted.

4. Conclusions

The current paper presents a new adsorbent, MgSiO3 functionalized with DL-cysteine (cys), designed for palladium ion recovery from waste solutions.
SEM, EDX and FTIR analyses revealed morphological changes in the surface of the adsorbent material after impregnation and confirmed the functionalization of MgSiO3 with DL-cysteine.
The modeling of the experimental data obtained in the batch system showed that the Sips isotherm best describes the adsorption process, because the correlation coefficient R2 approaches 1 and the maximum calculated adsorption capacity (9.62 mg g−1) is close to the experimentally determined value (9.23 mg g−1). The obtained adsorption capacity is better than those reported in the literature for other adsorbent materials due to the presence of the -SH and -NH2 groups in the structure of the functionalized material which allow the surface adsorption of Pd(II) by free electrons or by creating hydrogen bridges.
Palladium ion adsorption studies in a dynamic regime using a fixed-bed column are influenced by the adsorbent bed height (the output flow rate decreases as the fixed-bed height increases). The adsorption process is characterized by the Clark model for all the MgSiO3-cys material bed heights studied.

Author Contributions

Conceptualization, C.V., A.N., M.M., M.C. and V.M.; methodology, A.N., M.M. and G.M.; software, V.M. and G.M.; validation, C.V., A.N., P.N. and N.D.; formal analysis, A.N., N.D. and G.M.; investigation, C.V., A.N., M.M., M.C. and V.M.; resources, A.N. and P.N.; writing—original draft preparation, A.N. and M.C.; writing—review and editing, A.N. and G.M.; visualization, A.N., N.D. and P.N.; supervision, C.V. and A.N.; project administration, C.V. and A.N.; funding acquisition, C.V. and P.N. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by a grant of the Romanian Ministry of Research and Innovation, CCCDI—UEFISCDI, project number PN-III-P1-1.2-PCCDI-2017-0391/CIA_CLIM—Smart buildings adaptable to the climate change effects, within PNCDI III.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bailar, J.C.; Emeleus, H.J.; Nyholm, S.R.; Trotman-Dickeson, A.F. Comprehensive Inorganic Chemistry; Pergamon: Oxford, UK, 1982. [Google Scholar]
  2. Kumar, A.S.K.; Sharma, S.; Reddy, R.S.; Barathi, M.; Rajesh, N. Comprehending the interaction between chitosan and ionic liquid for the adsorption of palladium. Int. J. Biol. Macromol. 2015, 72, 633–639. [Google Scholar] [CrossRef] [PubMed]
  3. Rao, C.R.M.; Reddi, G.S. Platinum group metals (PGM); occurrence, use and recent trends in their determination. Trend Anal. Chem. 2000, 19, 565–586. [Google Scholar] [CrossRef]
  4. Wataha, J.C.; Hanks, C.T. Biological effects of palladium and risk of using palladium in dental casting alloys. J. Oral. Rehabil. 1996, 23, 309–320. [Google Scholar] [CrossRef]
  5. Wolowicz, A.; Hubicki, Z. Comparison of strongly basic anion exchange resins applicability for the removal of palladium(II) ions from acidic solutions. Chem. Eng. J. 2011, 171, 206–215. [Google Scholar] [CrossRef]
  6. Butler, J. Platinum Interim Review 2010; Johnson Matthey: Royston, UK, 2010. [Google Scholar]
  7. Farrauto, R.J.; Heck, R.M. Catalytic converters: State of the art and perspectives. Catal. Today 1999, 51, 351–360. [Google Scholar] [CrossRef]
  8. Polshettiwar, V.; Len, C.; Fihri, A. Silica-supported palladium: Sustainable catalysts for cross-coupling reactions. Coord. Chem. Rev. 2009, 253, 2599–2626. [Google Scholar] [CrossRef]
  9. Sharma, R.K.; Pandey, A.; Gulati, S.; Adholeya, A. An optimized procedure for preconcentration, determination and on-line recovery of palladium using highly selective di-phenyl-di-ketone-mono-thio-semi-carbazone modified silica gel. J. Hazard. Mater. 2012, 209–210, 285–292. [Google Scholar] [CrossRef]
  10. Bernardis, F.L.; Grant, R.A.; Sherrington, D.C. A review of methods of separation of the platinum-group metals through their chloro-complexes. React. Funct. Polym. 2005, 65, 205–217. [Google Scholar] [CrossRef]
  11. Cui, J.; Zhang, L. Metallurgical recovery of metals from electronic waste: A review. J. Hazard. Mater. 2008, 158, 228–256. [Google Scholar] [CrossRef]
  12. Gaita, R.; Al-Bazi, S.J. An ion-exchange method for selective separation of palladium, platinum and rhodium from solutions obtained by leaching automotive catalytic converters. Talanta 1995, 2, 249–255. [Google Scholar] [CrossRef]
  13. Kononova, O.N.; Leyman, T.A.; Melnikov, A.M.; Kashirin, D.M.; Tselukovskaya, M.M. Ion exchange recovery of platinum from chloride solutions. Hydrometallurgy 2010, 100, 161–167. [Google Scholar] [CrossRef]
  14. Park, Y.J.; Fray, D.J. Recovery of high purity precious metals from printed circuit boards. J. Hazard. Mater. 2009, 164, 1152–1158. [Google Scholar] [CrossRef] [PubMed]
  15. Rao, S.R. Resource Recovery and Recycling from Metallurgical Wastes; Elsevier: Amsterdam, The Netherlands, 2006. [Google Scholar]
  16. Durosaro, O.; el-Azhary, R.A. A 10-year Retrospective Study on Palladium Sensitivity. Dermatitis 2009, 20, 208–213. [Google Scholar] [CrossRef] [PubMed]
  17. Shultz, M.D.; Lassig, J.P.; Gooch, M.G.; Evans, B.R.; Woodward, J. Palladium a new inhibitor of cellulase activities. Biochem. Biophys. Res. Commun. 1995, 209, 1046–1052. [Google Scholar] [CrossRef] [PubMed]
  18. Kielhorn, J.; Melber, C.; Keller, D.; Mangelsdorf, I. Palladium—A review of exposure and effects to human health. Int. J. Hyg. Environ. Health 2002, 205, 417–432. [Google Scholar] [CrossRef] [PubMed]
  19. Borges, D.L.G.; Veiga, M.A.M.S.D.; Frescura, V.L.A.; Welz, B.; Curtius, A.J. Cloudpoint extraction for the determination of Cd, Pb and Pd in blood by electrothermal atomic absorption spectrometry, using Ir or Ru as permanent modifiers. J. Anal. At. Spectrom. 2003, 18, 501–507. [Google Scholar] [CrossRef]
  20. Ghaedi, M.; Shokrollahi, A.; Niknam, K.; Niknam, E.; Najibi, A.; Soylak, M. Cloud point extraction and flame atomic absorption spectrometric determination of cadmium(II), lead(II), palladium(II) and silver(I) in environmental samples. J. Hazard. Mater. 2009, 168, 1022–1027. [Google Scholar] [CrossRef]
  21. Komarek, J.; Krasensky, P.; Balcar, J.; Rehulka, P. Determination of palladium and platinum by electrothermal atomic absorption spectroscopy after deposition on a graphite furnace. Spectrochim. Acta B 1999, 54, 739–743. [Google Scholar] [CrossRef]
  22. Lee, J.Y.; Raju, B.; Kumar, B.N.; Kumar, J.R.; Park, H.K.; Reddy, B.R. Solvent extraction separation and recovery of palladium and platinum from chloride leach liquors of spent automobile catalyst. Sep. Purif. Technol. 2010, 73, 213–218. [Google Scholar] [CrossRef]
  23. Pan, L.; Zhang, Z. Solvent extraction and separation of palladium (II) and platinum (IV) from hydrochloric acid medium with dibutyl sulfoxide. Miner. Eng. 2009, 22, 1271–1276. [Google Scholar] [CrossRef]
  24. Priya, B.K.; Subrahmanayam, P.; Suvardhan, K.; Kumar, K.S.; Rekha, D.; Rao, A.V.; Rao, G.C.; Chiranjeevi, P. Cloud point extraction of palladium in water samples and alloy mixtures using new synthesized reagent with flame atomic absorption spectrometry. J. Hazard. Mater. 2007, 144, 152–158. [Google Scholar] [CrossRef] [PubMed]
  25. Soylak, M.; Tuzen, M. Coprecipitation of gold(III), palladium(II) and lead(II) for their flame atomic absorption spectrometric determinations. J. Hazard. Mater. 2008, 152, 656–661. [Google Scholar] [CrossRef] [PubMed]
  26. Bulut, V.N.; Tufekci, M.; Duran, C.; Soylak, M.; Kantekin, H. Selective Solid Phase Extraction for Separation and Preconcentration of Palladium from Gold Ore and Anode Slime after Complexation with a N4O2 Mixed Donor Ligand Derivative. Clean 2010, 38, 678–683. [Google Scholar] [CrossRef]
  27. Elci, L.; Soylak, M.; Buyuksekerci, E.B. Separation of gold, palladium and platinum from metallurgical samples using an Amberlite XAD-7 resin column prior to their atomic absorption spectrometric determinations. Anal. Sci. 2003, 19, 1621–1624. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  28. Sharma, R.K.; Mittal, S.; Koel, M. Analysis of trace amounts of metal ions using silica-based chelating resins: A green analytical method. Crit. Rev. Anal. Chem. 2003, 33, 183–197. [Google Scholar] [CrossRef]
  29. Soylak, M.; Elci, L. A sorbent extraction procedure for the preconcentration of gold, silver and palladium on an activated carbon column. Anal. Lett. 2000, 33, 513–525. [Google Scholar] [CrossRef]
  30. Ciopec, M.; Davidescu, C.M.; Negrea, A.; Muntean, C.; Popa, A.; Negrea, P.; Lupa, L. Equilibrium and Kinetic Studies of the Adsorption of Cr(III) ions onto Amberlite XAD8 impregnated with Di (2-ethylhexyl) phosphoric acid (DEHPA). Adsorp. Sci. Technol. 2011, 29, 989–1005. [Google Scholar] [CrossRef]
  31. Davidescu, C.M.; Ciopec, M.; Negrea, A.; Popa, A.; Lupa, L.; Dragan, E.S.; Ardelean, R.; Ilia, G. Synthesis, characterization and Ni(II) Ion separation properties of poly(styrene-co-divinylbenzene)-supported aminophosphonic acids. Polym. Bull. 2013, 70, 277–291. [Google Scholar] [CrossRef]
  32. Negrea, A.; Ciopec, M.; Lavinia, L.; Davidescu, C.M.; Popa, A.; Ilia, G.; Negrea, P. Removal of As(V) by Fe(III) loaded XAD7 impregnated resin containing di(2-ethylhexyl) phosphoric acid DEHPA): Equilibrium, Kinetic, and Thermodynamic modeling studies. J. Chem. Eng. Data 2011, 565, 3830–3838. [Google Scholar] [CrossRef]
  33. Kovacheva, P.; Djingova, R. Ion-exchange method for separation and concentration of platinum and palladium for analysis of environmental samples by inductively coupled plasma atomic emission spectrometry. Anal. Chim. Acta 2002, 464, 7–13. [Google Scholar] [CrossRef]
  34. Enzweiler, J.; Potts, P.J. The separation of platinum, palladium and gold from silicate rocks by the anion exchange separation of chloro complexes after a sodium peroxide fusion: An investigation of low recoveries. Talanta 1995, 42, 1411–1418. [Google Scholar] [CrossRef]
  35. Els, E.R.; Lorenzen, L.; Aldrich, C. The recovery of palladium with the use of ion exchange resins. Miner. Eng. 1997, 10, 1177–1181. [Google Scholar] [CrossRef]
  36. Kim, K.R.; Lee, M.S.; Ahn, D.H.; Yim, S.P.; Chung, H. Preparation of functional anion exchange resin and its selective adsorption of palladium in nitric acid medium. J. Ind. Eng. Chem. 2002, 8, 472–476. [Google Scholar]
  37. Lee, S.H.; Chung, H. Ion exchange characteristics of palladium and rhodium from a simulated radioactive liquid waste. J. Nucl. Sci. Technol. 2000, 37, 281–287. [Google Scholar] [CrossRef]
  38. Lee, S.H.; Chung, H. Ion exchange characteristics of palladium and ruthenium from a simulated radioactive liquid waste. Sep. Sci. Technol. 2003, 38, 3459–3472. [Google Scholar] [CrossRef]
  39. Lee, S.H.; Kim, K.R.; Jung, C.H.; Chung, H. Ion exchange characteristics of palladium from nitric acid solution by anion exchangers. Korean J. Chem. Eng. 1999, 16, 571–575. [Google Scholar] [CrossRef]
  40. Hubicki, Z.; Leszczynska, M. Sorption of palladium(II) chloride complexes on weakly, intermediate and strongly basic anion exchangers. Desalination 2005, 175, 227–236. [Google Scholar] [CrossRef]
  41. Hubicki, Z.; Leszczynska, M. Studies of sorption of Pd(II) micro quantities on strongly basic polyacrylate anion exchangers. Desalination 2005, 175, 289–295. [Google Scholar] [CrossRef]
  42. Negrea, A.; Gabor, A.; Davidescu, C.M.; Ciopec, M.; Muntean, C.; Negrea, P.; Duteanu, N.; Barbulescu, A. Rare Earth Elements Removal from Water Using Natural Polymers. Sci. Rep. 2018, 8, 316. [Google Scholar] [CrossRef] [Green Version]
  43. Gabor, A.; Davidescu, C.M.; Negrea, A.; Ciopec, M.; Lupa, L. Behaviour of silica and florisil as solid supports in the removal process of As(V) from aqueous solutions. J. Anal. Methods Chem. 2015, 2015, 562780. [Google Scholar] [CrossRef]
  44. Gabor, A.; Davidescu, C.M.; Popa, A.; Negrea, A.; Ciopec, M.; Motoc, M.; Lupa, L.; Negrea, P. Equilibrium studies for crown ether impregnated solid support used in the removal process of Nd(III), La(III), Sr(II), Tl(I), Eu(III). Rev. Chim. 2016, 67, 580–583. [Google Scholar]
  45. Gabor, A.; Davidescu, C.M.; Negrea, A.; Ciopec, M.; Muntean, C.; Negrea, P.; Ianasi, C.; Butnariu, M. Magnesium silicate doped with environmentally friendly extractants used for rare earth elements adsorption. Desalin. Water. Treat. 2017, 63, 124–134. [Google Scholar]
  46. Negrea, A.; Popa, A.; Ciopec, M.; Lupa, L.; Negrea, P.; Davidescu, C.M.; Motoc, M.; Minzatu, V. Phosphonium grafted styrene- divinylbenzene resins impregnated with iron(III) and crown ethers for arsenic removal. Pure Appl. Chem. 2014, 86, 1729–1740. [Google Scholar] [CrossRef]
  47. Ciopec, M.; Davidescu, C.M.; Negrea, A.; Grozav, I.; Lupa, L.; Muntean, C.; Negrea, P.; Popa, A. Statistical optimization of chromium ions adsorption on DEHPA-impregnated Amberlite XAD7. Environ. Eng. Manag. J. 2012, 11, 525–531. [Google Scholar] [CrossRef]
  48. Benamor, M.; Bouariche, Z.; Belaid, T.; Draa, M.T. Kinetic studies on cadmium ions by Amberlite XAD7 impregnated resin containing di(2-ethylhexyl) phosphoric acid as extractant. Sep. Purif. Technol. 2008, 59, 74–84. [Google Scholar] [CrossRef]
  49. Cortina, J.L.; Warshawsky, A. Developments in Solid-Liquid Extraction by Solvent-Impregnated Resins. In Ion Exchange and Solvent Extraction; Marinsky, J.A., Marcus, Y., Eds.; Marcel Dekker Inc.: New York, NY, USA, 1997; pp. 195–293. [Google Scholar]
  50. Davidescu, C.M.; Ciopec, M.; Negrea, A.; Popa, A.; Lupa, L.; Negrea, P.; Muntean, C.; Motoc, M. Use of di-(2-ethylhexyl)phosphoric acid (DEHPA) impregnated XAD7 copolymer resin for the removal of chromium (III) from water. Rev. Chim. 2011, 62, 712–717. [Google Scholar]
  51. Juang, R.S. Preparation, properties and sorption behaviour of impregnated resin containing acidic organo-phosphorus extractants. Proc. Natl. Sci. Counc. ROC(A) 1999, 23, 353–364. [Google Scholar]
  52. Mendoza, R.N.; Medina, I.S.; Vera, A.; Rodriguez, M.A. Study of the sorption of Cr(III) with XAD-2 resin impregnated with di-(2,4,4-trimethylpentyl) phosphinic acid (Cyanex 272). Solvent Extr. Ion Exch. 2000, 18, 319–343. [Google Scholar] [CrossRef]
  53. Muraviev, D.; Ghantous, L.; Valiente, M. Stabilization of solvent impregnated resin capacities by different techniques. React. Funct. Polym. 1998, 38, 259–268. [Google Scholar] [CrossRef]
  54. Disbudak, A.; Bektas, S.; Patir, S.; Genc, O.; Denizli, A. Cysteine-metal affinity chromatography: Determination of heavy metal adsorption properties. Sep. Purif. Technol. 2002, 26, 273–281. [Google Scholar] [CrossRef]
  55. Hisada, M.; Kawase, Y. Recovery of rare-earth metal neodymium from aqueous solutions by poly-g-glutamic acid and its sodium salt as biosorbents: Effects of solution pH on neodymium recovery mechanisms. J. Rare Earth 2018, 36, 528–536. [Google Scholar] [CrossRef]
  56. Langmuir, I. The adsorption of gases on plane surfaces of glass, mica and platinum. J. Am. Chem. Soc. 1918, 40, 1361–1403. [Google Scholar] [CrossRef] [Green Version]
  57. Kucuker, M.A.; Wieczorek, N.; Kuchta, K.; Copty, N.K. Biosorption of neodymium on Chlorella vulgaris in aqueous solution obtained from hard disk drive magnets. PLoS ONE 2017, 12, e0175255. [Google Scholar] [CrossRef]
  58. Freundlich, H.M.F. Over the adsorption in solution. J. Phys. Chem. 1906, 57, 385–470. [Google Scholar]
  59. Sips, R. On the Structure of a Catalyst Surface. J. Chem. Phys. 1948, 16, 490–495. [Google Scholar] [CrossRef]
  60. Bohart, G.S.; Adams, E.Q. Some aspects of the behaviour of charcoal with respect to chlorine, Behaviour of charcoal toward chlorine. Am. Chem. Soc. 1920, 42, 523–544. [Google Scholar] [CrossRef] [Green Version]
  61. Chu, K.H. Breakthrough curve analysis by simplistic models of fixed bed adsorption: In defense of the century-old Bohart-Adams model. Chem. Eng. J. 2020, 380, 122513. [Google Scholar] [CrossRef]
  62. Thomas, H.C. Heterogeneous ion exchange in a flowing system. J. Am. Chem. Soc. 1944, 66, 1664–1666. [Google Scholar] [CrossRef]
  63. Vilvanathan, S.; Shanthakumar, S. Removal from Aqueous Solution Using Native and Biochar Form of Tectona grandis. Environ. Prog. Sustain. Energy 2017, 36, 1030–1038. [Google Scholar] [CrossRef]
  64. Dlugosz, O.; Banach, M. Sorption of Ag+ and Cu2+ by Vermiculite in a Fixed-Bed Column: Design, Process Optimization and Dynamics Investigations. Appl. Sci. 2018, 8, 2221. [Google Scholar] [CrossRef] [Green Version]
  65. Madan, S.S.; De, B.S.; Wasewar, K.L. Adsorption performance of packed bed column for benzylformic acid removal using CaO2 nanoparticles. Chem. Data Collect. 2019, 23, 100267. [Google Scholar] [CrossRef]
  66. Sert, S.; Kutahyali, C.; Inan, S.; Talip, Z.; Cetinkaya, B.; Eral, M. Biosorption of lanthanum and cerium from aqueous solutions by Platanus orientalis leaf powder. Hydrometallurgy 2008, 90, 13–18. [Google Scholar] [CrossRef]
  67. Zhang, P.; Wang, Y.; Zhang, D.; Bai, H.; Tarasov, V.V. Calixarene-functionalized Graphene Oxide Composites for Adsorption of Neodymium Ions from aqueous phase. RSC Adv. 2016, 6, 30384–30394. [Google Scholar] [CrossRef]
  68. Dzieniszewska, A.; Kyziol-Komosinska, J.; Pajak, M. Adsorption and bonding strength of chromium species by ferrihydrite from acidic aqueous solutions. PeerJ 2020, 8, e9324. [Google Scholar] [CrossRef] [PubMed]
  69. Mohammed, N.; Grishkewich, N.; Waeijen, H.A.; Berry, R.M.; Tam, K.C. Continuous flow adsorption of methylene blue by cellulose nanocrystalalginate hydrogel beads in fixed bed columns. Carbohydr. Polym. 2016, 136, 1194–1202. [Google Scholar] [CrossRef] [PubMed]
  70. Chowdhury, Z.Z.; Zain, S.M.; Rashid, A.K.; Rafique, R.F.; Khalid, K. Breakthrough curve analysis for column dynamics sorption of Mn(II) ions from wastewater by using Mangostana garcinia peel-based granular-activated carbon. J. Chem. 2013, 2013, 959761. [Google Scholar] [CrossRef] [Green Version]
  71. Hasanzadeh, M.; Ansari, R.; Ostovar, F. Synthesis and application of CeO2/sawdust nanocomposite for removal of As(III) ions from aqueous solutions using a fixed bed column system. Glob. NEST J. 2016, 19, 7–16. [Google Scholar]
  72. Shafeeyan, M.S.; Daud, W.M.A.W.; Shamiri, A. A review of mathematical modeling of fixed-bed columns for carbon dioxide adsorption. Chem. Eng. Res. Des. 2014, 92, 961–988. [Google Scholar] [CrossRef]
  73. Netpradit, S.; Thiravetyan, P.; Towprayoon, S. Evaluation of metal hydroxide sludge for reactive dye adsorption in a fixed-bed column system. Water Res. 2004, 38, 71–78. [Google Scholar] [CrossRef]
  74. Patel, H. Fixed-bed column adsorption study: A comprehensive review. Appl. Water Sci. 2019, 9, 45. [Google Scholar] [CrossRef] [Green Version]
  75. Soto, M.L.; Moure, A.; Dominguez, H.; Parajo, J.C. Batch and fixed bed column studies on phenolic adsorption from wine vinasses by polymeric resins. J. Food Eng. 2017, 209, 52–60. [Google Scholar] [CrossRef]
  76. Han, R.P.; Wang, Y.; Zou, W.H.; Wang, Y.F.; Shi, J. Comparison of linear and nonlinear analysis in estimating the Thomas model parameters for methylene blue adsorption onto natural zeolite in fixed-bed column. J. Hazard. Mater. 2007, 145, 331–335. [Google Scholar] [CrossRef] [PubMed]
  77. Han, R.P.; Zhang, J.H.; Zou, W.H.; Xiao, H.J.; Shi, J.; Liu, H.M. Biosorption of copper(II) and lead(II) from aqueous solution by chaff in a fixed-bed column. J. Hazard. Mater. 2006, 133, 262–268. [Google Scholar] [CrossRef]
  78. Mondal, S.; Aikat, K.; Halder, G. Ranitidine hydrochloride sorption onto superheated steam activated biochar derived from mung bean husk in fixed bed column. Biochem. Pharmacol. 2016, 4, 488–497. [Google Scholar] [CrossRef]
  79. Wolowicz, A.; Hubicki, Z. Palladium(II) complexes adsorption from the chloride solutions with macrocomponent addition using strongly basic anion exchange resins, type 1. Hydrometallurgy 2009, 98, 206–212. [Google Scholar] [CrossRef]
  80. Uheida, A.; Iglesias, M.; Fontas, C.; Zhang, Y.; Muhammed, M. Adsorption Behaviour of Platinum Group Metals (Pd, Pt, Rh) on Nonylthiourea-Coated Fe3O4 Nanoparticles. Sep. Sci. Technol. 2006, 41, 909–923. [Google Scholar] [CrossRef]
  81. Mavhungu, A.; Mbaya, R.K.K.; Moropeng, M.L. Recovery of Platinum and Palladium Ions from Aqueous Solution Using Grape Stalk Waste. Int. J. Chem. Eng. Appl. 2013, 4, 354–358. [Google Scholar] [CrossRef] [Green Version]
  82. Morisada, S.; Kim, Y.H.; Yakuwa, S.; Ogata, T.; Nakano, Y. Improved adsorption and separation of palladium(II) and platinum(IV) in strong hydrochloric acid solutions using thiocyanate-retaining tannin gel. J. Appl. Polym. Sci. 2012, 126, E478–E483. [Google Scholar] [CrossRef]
  83. Wasikiewicz, J.M.; Mitomo, H.; Seko, N.; Tamada, M.; Yoshii, F. Platinum and Palladium Ions Adsorption at the Trace Amounts by Radiation Crosslinked Carboxymethylchitin and Carboxymethylchitosan Hydrogels. J. Appl. Polym. Sci. 2007, 104, 4015–4023. [Google Scholar] [CrossRef]
  84. Godlewska-Zylkiewicz, B.; Sawicka, S.; Karpinska, J. Removal of Platinum and Palladium from Wastewater by Means of Biosorption on Fungi Aspergillus sp. and Yeast Saccharomyces sp. Water 2019, 11, 1522. [Google Scholar] [CrossRef] [Green Version]
Figure 1. The appearance of the adsorbent material obtained by functionalizing MgSiO3 using DL-cysteine.
Figure 1. The appearance of the adsorbent material obtained by functionalizing MgSiO3 using DL-cysteine.
Ijerph 17 09500 g001
Figure 2. The scheme of the experimental Pd(II) removal installation in a fixed-bed adsorption column.
Figure 2. The scheme of the experimental Pd(II) removal installation in a fixed-bed adsorption column.
Ijerph 17 09500 g002
Figure 3. SEM image of adsorbent before and after impregnation.
Figure 3. SEM image of adsorbent before and after impregnation.
Ijerph 17 09500 g003
Figure 4. Energy dispersive X-ray (EDX) spectra for MgSiO3 and MgSiO3-cys materials.
Figure 4. Energy dispersive X-ray (EDX) spectra for MgSiO3 and MgSiO3-cys materials.
Ijerph 17 09500 g004
Figure 5. The FTIR spectra for commercial magnesium silicate and functionalized MgSiO3-cys.
Figure 5. The FTIR spectra for commercial magnesium silicate and functionalized MgSiO3-cys.
Ijerph 17 09500 g005
Figure 6. Influence of Pd(II) initial solution concentration on adsorption capacity of MgSiO3-cys.
Figure 6. Influence of Pd(II) initial solution concentration on adsorption capacity of MgSiO3-cys.
Ijerph 17 09500 g006
Figure 7. Equilibrium isotherms for adsorption of Pd(II) ions onto MgSiO3-cys.
Figure 7. Equilibrium isotherms for adsorption of Pd(II) ions onto MgSiO3-cys.
Ijerph 17 09500 g007
Figure 8. Breakthrough curves for Pd(II) adsorption on a MgSiO3-cys fixed-bed column at three fixed-bed bed height columns (BHCs) (T = 298 K, L = 2.1–7.0 cm, Ci = 60 mg L−1 Pd(II), and Q = 7 mL min−1).
Figure 8. Breakthrough curves for Pd(II) adsorption on a MgSiO3-cys fixed-bed column at three fixed-bed bed height columns (BHCs) (T = 298 K, L = 2.1–7.0 cm, Ci = 60 mg L−1 Pd(II), and Q = 7 mL min−1).
Ijerph 17 09500 g008
Figure 9. Bohart–Adams model for the adsorption of Pd(II) in a fixed-bed column at various MgSiO3-cys amounts.
Figure 9. Bohart–Adams model for the adsorption of Pd(II) in a fixed-bed column at various MgSiO3-cys amounts.
Ijerph 17 09500 g009
Figure 10. Thomas model for the adsorption of Pd(II) in a fixed-bed column at various MgSiO3-cys amounts.
Figure 10. Thomas model for the adsorption of Pd(II) in a fixed-bed column at various MgSiO3-cys amounts.
Ijerph 17 09500 g010
Figure 11. Yoon–Nelson model for the adsorption of Pd(II) in a fixed-bed column at various MgSiO3-cys amounts.
Figure 11. Yoon–Nelson model for the adsorption of Pd(II) in a fixed-bed column at various MgSiO3-cys amounts.
Ijerph 17 09500 g011
Figure 12. Clark model for the adsorption of Pd(II) in a fixed-bed column at various MgSiO3-cys amounts.
Figure 12. Clark model for the adsorption of Pd(II) in a fixed-bed column at various MgSiO3-cys amounts.
Ijerph 17 09500 g012
Table 1. Parameters of isotherm models for adsorption of palladium ions onto MgSiO3-cys.
Table 1. Parameters of isotherm models for adsorption of palladium ions onto MgSiO3-cys.
qm,exp
(mg g−1)
Freundlich IsothermLangmuir IsothermSips Isotherm
KF
(mg g−1)
1/nR2KL
(L mg−1)
qm
(mg g−1)
R2KSqm
(mg g−1)
1/nSR2
9.231.920.550.75990.1014.950.86880.019.620.340.9953
Table 2. Pd(II) adsorption process parameters in a fixed-bed column.
Table 2. Pd(II) adsorption process parameters in a fixed-bed column.
Column Adsorption Parameters Specification
Bohart–Adams modelMgSiO3-cys amounts (g)kBA
(L mg−1 min−1)
N0
(mg L−1)
R2
33.45 × 10−31688.80.9755
51.89 × 10−31960.80.9777
101.90 × 10−31407.70.9717
Thomas modelMgSiO3-cys amounts (g)kTh
(L mg−1 min−1)
qTh
(mg g−1)
R2
32.50 × 10−33.330.9911
52.29 × 10−33.880.9961
102.99 × 10−32.850.9704
Yoon–Nelson modelMgSiO3-cys amounts (g)kYN
(min−1)
τ
(min)
R2
30.213724.400.9727
50.137646.050.9941
100.146968.300.9722
Clark modelMgSiO3-cys amounts (g)r
(min−1)
AR2
30.215695090.9936
50.12972900.9973
100.14051290.9881
Table 3. The equilibrium adsorption capacity of different sorbents reported in literature compared to the proposed MgSiO3-cys material.
Table 3. The equilibrium adsorption capacity of different sorbents reported in literature compared to the proposed MgSiO3-cys material.
MaterialAdsorption ConditionsAdsorption Capacity, (mg g−1)References
Lewatit MP-500 resinContact time = 2 h
Temperature = 298 K
Initial concentration of Pd(II) complex = 0.1 M
8.45[79]
Nonylthiourea-coated Fe3O4Contact time = 30 min Temperature = 295 K
pH = 2.5
Initial concentration of Pd(II) = 0.076 (mmol g−1)
8.10[80]
Grape stalk impregnated with orthophosphoric acidContact time = 4 h
Temperature = 295 K
pH = 1.5
Initial concentration of Pd(II) = 60 (mg L−1)
1.4[81]
Thiocyanate retaining tannin gelContact time = 2 h,
Temperature = 298 K,
Initial concentration of Pd(II) = 0.001 M
0.065[82]
Crosslinked carboxymethyl chitosan hydrogelsContact time = 2 h
Temperature = 295 K
pH = 4,
Initial concentration of Pd(II) = 100 ppb
2.6[83]
Fungi Aspergillus sp.Contact time = 45 min,
Temperature = 298 K
pH = 2.5–3.5
Initial concentration of Pd(II) = 0.075 (mg L−1)
4.28[84]
MgSiO3-cysContact time = 1 h
Temperature = 298 K
pH = 2
Initial concentration of Pd(II) = 40 (mg L−1)
9.23This paper
Publisher′s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Vancea, C.; Mihailescu, M.; Negrea, A.; Mosoarca, G.; Ciopec, M.; Duteanu, N.; Negrea, P.; Minzatu, V. Batch and Fixed-Bed Column Studies on Palladium Recovery from Acidic Solution by Modified MgSiO3. Int. J. Environ. Res. Public Health 2020, 17, 9500. https://doi.org/10.3390/ijerph17249500

AMA Style

Vancea C, Mihailescu M, Negrea A, Mosoarca G, Ciopec M, Duteanu N, Negrea P, Minzatu V. Batch and Fixed-Bed Column Studies on Palladium Recovery from Acidic Solution by Modified MgSiO3. International Journal of Environmental Research and Public Health. 2020; 17(24):9500. https://doi.org/10.3390/ijerph17249500

Chicago/Turabian Style

Vancea, Cosmin, Maria Mihailescu, Adina Negrea, Giannin Mosoarca, Mihaela Ciopec, Narcis Duteanu, Petru Negrea, and Vasile Minzatu. 2020. "Batch and Fixed-Bed Column Studies on Palladium Recovery from Acidic Solution by Modified MgSiO3" International Journal of Environmental Research and Public Health 17, no. 24: 9500. https://doi.org/10.3390/ijerph17249500

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop