Next Article in Journal
Concerns or Desires Post-Pandemic: An Extended MGB Model for Understanding South Korean Residents’ Perceptions and Intentions to Travel to China
Previous Article in Journal
University Students’ Self-Rated Health in Relation to Perceived Acoustic Environment during the COVID-19 Home Quarantine
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Thermal Discomfort Levels, Building Design Concepts, and Some Heat Mitigation Strategies in Low-Income Communities of a South Asian City

1
Department of Environmental Sciences and Engineering, Government College University Faisalabad, Faisalabad 38000, Pakistan
2
School of Climate Change and Adaptation, University of Prince Edward Island, Charlottetown, PE C1A 4P3, Canada
3
Climate Energy and Water Research Institute, Pakistan Agricultural Research Council, Islamabad 44000, Pakistan
4
Faculty of Sustainable Design Engineering, University of Prince Edward Island, Charlottetown, PE C1A 4P3, Canada
*
Authors to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2021, 18(5), 2535; https://doi.org/10.3390/ijerph18052535
Submission received: 5 February 2021 / Revised: 28 February 2021 / Accepted: 1 March 2021 / Published: 4 March 2021

Abstract

:
Heat stress provokes thermal discomfort to people living in semiarid and arid climates. This study evaluates thermal discomfort levels, building design concepts, and some heat mitigation strategies in low-income neighborhoods of Faisalabad, Pakistan. The outdoor and indoor weather data are collected from April to August 2016 using a weather station installed ad hoc in urban settings, and the 52 houses of the five low-income participating communities living in congested and less environment-friendly areas of Faisalabad. The discomfort index values, related to the building design concepts, including (i) house orientation to sunlight and (ii) house ventilation, are calculated from outdoor and indoor dry-bulb and wet-bulb temperatures. Our results show that although June was the hottest month of summer 2016, based on the monthly mean temperature of the Faisalabad region, the month of May produced the highest discomfort levels, which were higher in houses exposed to sunlight and without ventilation. The study also identifies some popular heat mitigation strategies adopted by the five participating low-income communities during various heat-related health complaints. The strategies are gender-biased and have medical, cultural/customary backgrounds. For example, about 52% of the males and 28% of the females drank more water during dehydration, diarrhea, and eye infection. Over 11% and 19% of the males and females, respectively, moved to cooler places during fever. About 43% of the males and 51% of the females took water showers and rested to combat flu (runny nose), headache, and nosebleed. The people did not know how to cure muscular fatigue, skin allergy (from a type of Milia), and mild temperature. Planting trees in an area and developing open parks with greenery and thick canopy trees can be beneficial for neighborhoods resembling those evaluated in this study.

1. Introduction

There has been a rise of 0.74 °C in the global average temperature during the last 100 years—the latter half of which experienced extreme temperatures and intense precipitations with an estimated rise to 1.8–4.0 °C (estimated average of 3.0 °C) by 2100 [1]. The weather of the arid and semiarid zone countries is specifically inclined to heat stress. The low-income people of these countries face harsh weather challenges with a probability of deadly events [2]. Heat stress is considered as the key health issue of people living in low-income areas of Asian cities as declared by IPCC (the Intergovernmental Panel on Climate Change) [3]. For example, the heat stress during 2015 resulted in mortalities in India and Pakistan. Relationships have been established between temperature and mortality, with a strong link between weather and the fitness of people [4]. Mitigation strategies are conventionally derived from the common outdoor meteorological information, such as temperature and humidity, generally used to produce warning signs for heatwaves [5].
Pakistan is among South Asian countries with its numerous regions having arid and semiarid climates. The country is categorized as the world’s most climate-vulnerable region [6]. Heat stress warnings are commonly issued during the summer days in Pakistan. The local outdoor temperature causes people’s exposure to heat stress [7]. Poor living conditions (i.e., no air conditioners to run during summers) and improper design of the living places, such as buildings without vents and built with no plans, by an architect, strongly affect the indoor environment [8,9]. The buildings of small size or without windows act like caves [10]. The urban heat island effect extends the sufferings of the people from heat stress, particularly in congested low-income neighborhoods that cannot afford air conditioning to combat harsh weather [11,12]. The low-income communities in major cities of Pakistan, including Faisalabad live under congested conditions. Their houses do not have proper building design concepts. They are built with poor ventilation and unavoidable orientation to the sun. Most of the houses in Pakistan face South and/or East to avoid sun orientation during summer. North–East and South–East oriented houses/windows/vents are recommended for ventilation. However, the low-income communities do not have control over choosing the orientation of their houses because of limited available places. House orientation to the sun exacerbates indoor temperature and humidity. These conditions lead to cause a high feel-like effect (of temperature) for dwellers during the early summer of humid days that worsen during peak-temperature hours of the day. The feel-like effect is not the real temperature and is based on air temperature, wind speed, and humidity [13]. The phenomenon of the feel-like effect is temperature and/or thermal sensation felt by a human body being hot or cold. Once exposed to winds, human skin becomes colder than the real temperature because the winds draw away body heat with sweat. Therefore, no perspiration during humid conditions keeps the human body hotter than the real temperature.
In arid or semiarid zones, the climates with little to no humidity in the air, allow solar radiation to penetrate the earth without any interference [14]. In such situations, the earth’s surface heats up during the day because of solar radiations and cools down during the night because nothing blocks or traps the heat generated during the day [13]. Coastal entities, such as Karachi in Pakistan, face heatwaves that result from interactions of land-ocean-atmosphere processes causing increases in humidity and temperature [15]. Climate change is expected to exacerbate the frequency, intensity, and duration of heatwaves [16].
People living indoors or working outdoor face exposure to heat hazards in low-income neighborhoods of South Asian cities. Exhaust from the air conditioners, as well as buildings without air conditioning, both lead to the conditions of severe heat stress outdoor and indoors. Night-time indoor temperatures stand important because of the value of this time when residents of a building respite from the harsh hot day. The interactions of indoor temperature and humidity result in thresholds for heat stress facing the dwellers [17], resulting in heat-related morbidity and mortality, heat stress, ground-level ozone, and undernutrition [18]. The thermal thresholds of a certain value have been reported to cause health risks. In Barcelona, Spain, on higher humid days, it was found that a 2 °C higher temperature than the threshold (23 °C) accompanied with relative humidity above 85% potentially caused health risks. Thresholds have been reported riskier for elderly people than youngsters [19], and measured in terms of discomfort index—an index for measuring the discomfort felt in warm weather because of the combined effects of ambient air temperature and humidity of the air. High discomfort level, caused by heat waves, adversely affects human well-being [20]. Especially, high night-time temperatures disturb sleep, adversely affect next-day activities, and even to the extent of mortality in arid or semiarid climate zone [21,22].
Nicol and Roaf [23] explained the concepts of understanding behind the thermal relationship between people and buildings, socio-economic aspects [24], psychology [25], physiology [26] which underlies the related health effects and the ways to interpret the body’s response to the environment either as comfort or discomfort [27]. Worldwide, the varying cultural and architectural setups have increasing pressures to exacerbate the challenge of comfortable living [23]. A research question for this study was that how the outdoor weather conditions and building design concepts raise the indoor discomfort levels. Several reports exist on thermal comfort faced by the people living inside modern buildings (see Nicol and Roaf [23], and the references therein). However, thermal discomfort levels, building design concepts, and some heat mitigation strategies in low-income neighborhoods of cities in arid/semiarid zones of South Asia remained unreported. Therefore, this study evaluated thermal discomfort levels, building design concepts, and some heat mitigation strategies in low-income neighborhoods of Faisalabad, Pakistan.

2. Materials and Methods

Planning for this study started during a seminar held at the Government College University Faisalabad, Pakistan. The theme of this gathering was to create awareness about heat stress mitigation techniques. These activities were in the wake of the June 2015 Karachi heatwaves, causing deaths of over 700 people from dehydration and heatstroke [28]. Faisalabad was chosen as a study site because of having Karachi resembling slums and congested neighborhoods of low-income communities. Another edge of this study location was the availability of the basic instrumentations from projects of the Higher Education Commission of Pakistan and the Himalayan Adaptation, Water and Resilience (HI-AWARE) consortium supported by the Collaborative Adaptation Research Initiative in Africa and Asia. A student (the lead author) was hired to conduct this research for her Ph.D. dissertation supervised by the second author of this report.
The project team designed a questionnaire and held awareness seminars in the low-income communities of Faisalabad (Figure 1). After the seminars, the heads of some willing households were approached through the cooperative community leaders who were educated about the study’s importance and convinced for cooperation. A general survey questionnaire was shared with the potential participant about data to be collected for this study. Some of the questions, leading to privacy disclosure, were simplified on the demand of the participants. The final questions included socio-economic conditions, family information, health-related issues, and customary heat mitigation strategies adopted by the dwellers to combat heat-related complaints. Access to the personal/family rooms of the participants was granted on the terms and conditions to let female students only collect indoor data and avoid taking photos of the indoor environments.

2.1. Study Sites

This study was conducted in Faisalabad, which is the third-largest city in Pakistan. The population of Faisalabad is about eight million. Faisalabad features a semiarid climate (BWh) in Köppen-Geiger classification with very hot and humid summers and cool, dry winters. This city is situated on the plains of the northeast of Punjab with an elevation of 184 m above mean sea level at longitude 73–74° East, and latitude 30–31.5° North. The study site comprised five low-income neighborhoods in the western and central part of the city; (i) the clock tower district, which is the city center comprising old architecture buildings, (ii) D block of Gulam-Muhammad Abad, which is characterized by more vegetation like trees and shrubs and wide roads, (iii) Gulam-Muhammad Abad, a congested area with few trees but shades from buildings, (iv) Muradabad–a slum alongside the city’s main drain, and (v) Babuwala—a slum across main Jhang Road, densely populated and with little vegetation (Figure 2). A historical record of monthly means record of the past 50-years weather data for rainfall, minimum temperature, and maximum temperature for the Faisalabad region is shown in Figure 2.
The participants of this study were low-income communities of Faisalabad who work as a laborer on a daily basis and whose literacy rate is below 10%. As depicted in the participating communities’ photos, taken with permission, their living standards are below the international poverty lines set by the United Nations (Figure 3). They were reluctant to mention it, but their daily income was less than $2 US. One out of the 6–7 members of a family worked for a living, and the rest were his/her dependents. Convincing such low-literate and low-income communities to participate in this study was challenging as there were no financial incentives to offer them for their cooperation. Additionally, in a Muslim and cultural setup of South Asia, permissions to enter their private/personal living places were hard to get manage for the continuous period of five months without any promises to help them ease their living conditions, even to the extent of buying them a pedestal fan with a minimal cost of $100 US. Figure 3 presents snapshots of the neighborhood (left) and indoor conditions (right) of (a) Site 1: The clock tower district; (b) Site 2: D block of Gulam-Muhammad Abad; (c) Site 3: Gulam-Muhammad Abad; (d) Site 4: Muradabad, and (e) Site 5: Babuwala.

2.2. Households and Housing Building Design Concepts Data

With the help of community heads, 52 sample houses were selected within the five low-income participating communities. Detailed household data were also collected by interviewing the house owners individually. The survey questionnaire designed to collect human behavior data comprised questions about health conditions specific to heat, as well as questions based on socio-economic parameters. The regular questionnaire was done on a monthly basis. The socio-economic parameters included the weekly income of the entire family, monthly electricity bill, and power cut-off hours they are suffering. This questionnaire included the sections like how they are coping with heat stress and what type of health issues they are facing gender-wise.
The questionnaire included questions like (i) households’ ratio (i.e., number of persons per house), (ii) gender proportion (female to male ratio), (iii) crowding ratio (the number of rooms per persons), (iv) building design concept (i.e., if houses with proper ventilation, such as windows and/or vents, and if the houses were exposed to sunlight versus a house with shades of trees, the neighboring building, or an upper story construction), (v) possession of necessities, such as a fan, washing machine, evaporative cooler, air conditioner, or fridge, and (vi) experience of a daily power outage. Description of variables and summary statistics of socio-economic conditions and building design concepts of the house considered in this study are given in Table 1.
The average family size of the surveyed communities was 6.6 persons per household. There were congested situations making houses in the study area overcrowded as judged from the ratio between the number of rooms and people per house, e.g., 292 people/114 rooms = 2.56. Most of the houses had common building materials, such as tiles in the roof and bricks in walls. Rooftops were made from tiles, and walls were made up of bricks. Although all households owned one fan (ceiling and/or pedestal), power shortage was a permanent problem in the whole study area.
Houses of all the five communities had no proper design concepts. For example, the rooms did not have poor ventilation (on the two opposite walls). Over half of the rooms (~32) had one or more windows, and the rest (~20) were without a window. Half of the rooms had vents, and <10 of the rooms had two or more, but improperly placed vents. About 90% of the houses were covered with shades either from the neighboring buildings and/or an upper story (47) and the rest (5) with trees. About 40% of the houses faced South, and 25% of the houses were oriented eastward. This is a common house building concept regarding house orientation in Pakistan because of the dominating sun path and radiations during peak sun hours in summer. Owners of the rest of the houses, facing North and West, had no options to choose the orientation of their houses because of limited available space.

2.3. Temperature Measurements

The outdoor and indoor measurements of temperatures were needed to calculate the discomfort index for various experimental setups. The data collection setup for this study was specially designed to avoid data variability, underestimations, and dimension error [29]. For indoor dry-bulb temperature (Td) measurements, data loggers (HOBO® Temp Data Logger UX100-001, HOBO® Temp/RH 2.5% Data Logger (UX100-011) were installed in the participating household to record and download data with a special shuttle (HOBO® U-Shuttle, U-DT-x) or with a laptop/tablet. All the loggers were validated in a climate chamber against a licensed calibrated data logger. The accuracy of temperature sensors was ±0.21 °C to stand out from 10 to 90% for humidity. Data loggers were installed 1.5 m high on walls having no windows and/or minimal vents. The loggers were also kept away from heat, cold, moist, and dry sources, including the kitchen, heater, lights, fan, and water cooler, as suggested by Nguyen et al. [30] and Smargiassi et al. [8]. The indoor data were collected from 1 April to 31 August 2016 (150 days), which are historically summer months in Pakistan.
The indoor wet-bulb temperature (Tw) was measured using Kestrel 4600 Heat Stress Meter (Extreme Meters C/O Weather Republic, LLC. 3947 W Lincoln Hwy Unit 304 Downingtown, PA, USA) during the fortnight visits of each of the 52 houses, made for downloading the indoor Td data from HOBO® data loggers, during five months of the study period. The Kestrel device measures Tw using an externally mounted, hermetically sealed thermistor sensor. The device was calibrated according to the manufacturer’s instructions, and data were recorded after the meteorologic values stabilized in about 6–7 min [31].
For outside weather data, an automated weather station (Wireless Vantage Pro2 Plus, Davis Instruments, Hayward, CA, USA) that included radiation sensors and a daytime fan-aspirated radiation shield for the temperature and humidity devices was installed ad hoc within the old campus of the Government College University, Faisalabad for real-time outdoor weather information of areas mimicking city center’s paved roads and surrounding buildings. Late delivering, installation of the weather station, and downloading issues with correct time-series data, delayed the outdoor data collection by 17 days. Therefore, the outdoor data became available from 17 April to 31 August 2016 (134 days).

2.4. Data Analysis

2.4.1. Discomfort Index

Discomfort levels experienced by people were evaluated using the discomfort index formula introduced by Sohar et al. [32] and used by Ren et al. [33]. Sohar’s method compares the cumulative discomfort index (CDI), and cumulative effective temperature (CET) obtained from meteorological data [33]. This method is based on the sums CDI and CET values for each hour of the day and night, and modification of the Thom [34] method given below.
Discomfort Index = 0.4 (Td + Tw) + 15
The formula of discomfort index designed by Thom [34] is for Td and Tw measured in °F. According to this formula, the Td and Tw are “equally important in respect to man’s feeling of discomfort in heat” therefore, Td and Tw measured in °C can represent discomfort index calculated as:
Discomfort Index = (0.5 × Td + 0.5 × Tw)
The formula of Equation (2) used in this study is based on the observations of Thom [34] that the changes in the sum of Td and Tw follow a similar pattern as changes in the effective temperature under the same conditions. The advantage of using Equation (2) is its advantage over Equation (1) that the former does not necessitate the measuring of the wind velocity, which is necessary for the estimation of the effective temperature [32].

2.4.2. Time-Series Data

The time-series outdoor Td and Tw data were available from the weather station installed ad hoc for this study. The time-series indoor Td data were available from HOBO® data loggers installed in each household. However, the time-series indoor Tw data were not available as it was only measured fortnightly instead of daily Tw separately for days and nights as mentioned in Section 2.3. Therefore, for time-series indoor Tw, two assumptions were made. First, to use representative Tw calculated from the regression model of the Engineering ToolBox [35] drawn as Figure 4a. Second, to use representative averaged indoor Tw calculated from outdoor Tw-Td relationship (Figure 4b). These assumptions were based on the literature reporting the use of representative data and assumptions adopted by Oreszczyn et al. [36], who evaluated mold (mould) and winter indoor relative humidity in low-income households in England and used the representative values of vapor pressure access from outdoor temperature. Similarly, Künzel [37] calculated a representative indoor relative humidity from moisture load using a developed relationship between the two variables with the cautionary statement that the estimated values correspond only to mean conditions and do not show the possible ranges. Once determining that since the tendency of the linear relation between moisture load and outdoor temperature of one location was obvious, they used the regression equation of the individual values to produce a summary of analog regression lines of all investigated homes. Representative values and assumptions have been commonly used in the literature of indoor/outdoor temperature and relative humidity/water vapor [38,39,40,41].
The validity of these assumptions was confirmed from the discomfort index values calculated using the measured indoor Td, Tw data and compared with the discomfort index values from indoor Td, indoor Tw calculated from the two regression models of Figure 4 (Table 2). The average discomfort index calculated from the measured indoor Td, Tw data deviated 1.44 °C from its mean in comparison with 1.63 and 2.24 °C from the respective means Figure 4a,b models. Based on a smaller deviation from the mean and the published nature, the Figure 4a relationship was used to calculate the missing values of indoor Tw from the respective indoor Td.
The risk of heat stress is experienced as mild or no discomfort for discomfort index below 24 °C, a moderate level of discomfort is experienced for discomfort index in the range of 24–28 °C, and discomfort index above 28 °C is considered as the severe level of discomfort [32].

2.5. The Interviews and Survey Questionnaires

Besides data collection from data loggers installed in houses of the five low-income communities, this study involved collecting information from the participating communities through interviews and survey questionnaires. All the 292 people of the 52 households were interviewed. The age group and gender of the interviewee are given in Table 3. Since over 90% of the participants were not literate, the survey questionnaires were filled in by the researchers from replies of the interviewees to various questions. The survey questions were about the sufferings of the people during summer days and the mitigation strategies adopted to combat heat-related health complaints. Children who were unable to express their feelings were represented by their mothers or elder siblings. The heat mitigation strategies were meant for adaptation to the changes specific to their sufferings during summer 2016.

3. Results

3.1. Difference between Indoor and Outdoor Temperatures

The indoor night-time discomfort indices were higher during May and June than during the rest of the months of the study period (Figure 5a). There were similar trends in the variations of outdoor discomfort indices (Figure 5b). The indoor discomfort index line remained farther below its respective Td line because of the big difference between the Td and Tw throughout the summer period (Figure 5a). Contrary to this, the outdoor discomfort index line remained closer to its respective Td line because of the smaller difference between the Td and Tw throughout the summer period as compared with the indoor lines (Figure 5b). A comparison of indoor and outdoor diurnal discomfort indices showed that the two indices lines overlapped each other during April and May, but the indoor discomfort index line remained below the outdoor discomfort index line for the rest of the summer months (Figure 5c). The increases in discomfort indices during April, May, and June were partly because of the historically prevailing continued drier conditions in Faisalabad during these months and the months before this period (Figure 2) than during July 2016, which received a record 178 mm of cumulative rain (Figure 5d) that might have resulted in lowering of discomfort indices during July and August 2016 both indoor and outdoor.
The effects of dry and wet conditions were substantial on indoor Td, Tw, and the resultant discomfort indices than on outdoor discomfort indices (Figure 6). The effects were greater on day and night indoor temperatures than on day and night outdoor temperatures (Figure 6b,d, respectively), as shown by greater offsetting of Td by Tw (Figure 5a,c, respectively). The effect of July rainfall was obvious on the squeezed distance between outdoor day and night Td, Tw, and discomfort indices (Figure 6b,d, respectively). Averaged over the five summer months of the study period, the daytime outdoor values of discomfort indices remained in the range of severe level of discomfort (>28 °C), while the night-time indoor and outdoor, and daytime indoor values of discomfort indices were in the top-end of mild discomfort levels (24–28 °C).

3.2. Daily and Hourly Calculated Discomfort Indices

Since May data reflected the highest discomfort index, further analysis of this dataset was conducted to evaluate variations in discomfort levels experienced by people during this month. Analysis of the daily variations revealed that the first three days of this month (1–3 May 2016) and the last week (21–28 May 2016) had the maximum discomfort index regardless of the design concepts of buildings (Figure 7). The data analysis further showed that direct exposure to sunlight caused a higher discomfort index than the houses having shades of trees or from the neighboring buildings (Figure 7a). There was a substantial difference between the discomfort index values of the shaded and non-shaded houses during the middle of the month (10–20 May 2016). The rest of the high discomfort index days did not have such a substantial difference. However, the difference between the discomfort index values of the ventilated and non-ventilated rooms was observed throughout May 2016, while the former type of rooms had a lower discomfort index than the discomfort index of the latter (Figure 7b).
The discomfort level experienced by people of the study houses touched its peak on 23 May 2016. Analysis of the diurnal variations calculated for 23 May 2016, reflected that the hours from 13:00 to 16:00 on this day had the highest discomfort index, and the morning hours of 07:00 to 09:00 and midnight durations of 21:00 to 00:00 had the lowest and medium discomfort index values, respectively, for all types of house building design concepts (Figure 8).
Almost similar effects of the house building design concepts were observed when hourly collected data were analyzed for the effect of house exposure to sunlight (Figure 8a), and house ventilation (Figure 8b). The houses exposed to sunlight and rooms without vent had higher values of discomfort index than the discomfort index of rooms of their opposite respective design concept.

3.3. Mitigation Strategies

Analysis of the survey questionnaire data revealed that the orientation of the house to the angle of the sun was used by the people to set their living habits and rules. For example, to ensure a living comfort, the people, especially females, preferred to live inside a house during different timings of the day. In addition to taking typical custom heat mitigation measures, including taking regular showers, drinking plenty of water, spending summer nights outside on lawns or the rooftops, and remaining under the tree shades outside the homes during peak hot hours. Under the cultural conditions, males of the community had the advantage to spend the peak hot hours outside their home under the shades of available trees. This benefit was not available to the female community.
With outdoor angles for sunlight, different parts of the house or a particular room had advantages and/or disadvantages for the people. Based on the sunlight angle, certain vents, windows, and doors remained shut or open by people to combat heat at varying hours of the day. When high temperature followed a daily peak-hour power cut, health issues arose, including diarrhea, dehydration, headache, and/or fever for both genders (Table 4).
Some popular heat mitigation strategies adopted by the five participating low-income communities during various heat-related health complaints were extracted from the analysis of the survey interviews and questionnaires. The strategies were gender-biased and had medical, cultural/customary backgrounds. For example, about 52% of the males and 28% of the females drank more water during dehydration, diarrhea, and eye infection. Over 11% and 19% of the males and females, respectively, moved to cooler places during fever. About 43% of the males and 51% of the females took water showers and rested to combat flu (runny nose), headache, and nosebleed. The people did not know how to cure muscular fatigue, skin allergy (from a type of Milia), and mild temperature.

4. Discussion

This study used meteorological, socio-economic, and health-related data collected from five low-income communities in Faisalabad’s neighborhood. Analysis of the meteorological data revealed that summer 2016 was harsh during the first two months when the indoor discomfort level was higher than the outdoor discomfort level dictating the neighborhood of the low-income families in Faisalabad spend their nights in cooler places outside their rooms (either in lawns or on the rooftops) to look for a little comfort against heat.
Rooms under the shades of trees or in the shades of neighboring buildings that did not have direct exposure to the sunlight had a lower discomfort level than the house without shades. Several environmental variables influence environmental conditions, including ambient air temperature, relative humidity, sunlight, wind direction, as well as speed, and solar radiation. These environmental conditions dictate the thermal comfort of an area. Additionally, the neighborhood of a house provides thermal comfort to the people of the house. Shades from the neighboring buildings and the trees improve thermal comfort, especially during summer [42,43]. Literature suggests that indoor thermal comfort can be achieved without using a mechanically or electrically build cooling system if the indoor temperature remains within the range of mild to moderate discomfort levels [44]. One of the discussed options is the use of specific types and layers of building walls that can play a significate role in regulating indoor air temperature [45,46]. Therefore, the application of appropriate materials for efficient building envelope design would be an effective alternative to maintain mild to moderate discomfort levels for low-income communities of cities like Faisalabad.
The study results are in concurrence with the findings of Astrom [47], who also reported sensitivity of indoor temperature to outdoor temperature primarily based on house building design concepts, outdoor conditions of a locality, and the outdoor temperature itself. However, house design concepts were related to old wisdom-based construction protocols; for example, well-ventilated high-ceiling, and shaded rooms either with trees, the neighboring buildings, or by an upper story construction were able to mitigate outdoor temperature in this study.
The amount of heat transferred through the walls and rooftops of the building made from various materials depends on the conduction, convection, and radiation capacity of the building materials [48]. During the daytime, the solar radiation hits the surfaces of external walls and rooftops. A part of the is released to the outdoor environment, and the other part is absorbed and conducted across the material. Theoretically, the inner surface of the walls or the rooftop, exposed to the outdoor temperature, exchange heats with the room air and other objects inside the room through convection and radiation. These two heat transfer methods regulate the indoor air temperature and consequently influence the level of discomfort inside the room. The heat exchange rate depends on the solar radiation, indoor temperature, outdoor temperature, material thermophysical properties, and exposed surface area.
Information collected from the survey questionnaire showed that people of the low-income areas of Faisalabad followed various mitigation strategies to combat heat discomforts depending upon the gender orientation of the people who face higher heat indoor during the first few months of summer. Large variation exists in indoor thermal comfort according to different climates, times of the year, and cultures [23]. While during night-time, the night indoor temperature remained higher than the outdoor usual temperature emphasizing the need to adapt to the challenging conditions of spending nights outside their rooms.
In addition to taking typical custom heat mitigation measures, including taking regular showers, drinking plenty of water, spending summer nights outside on lawns or the rooftops, and remaining under the tree shades outside the homes during peak hot hours, planting trees in an area, and developing open parks with greenery and thick canopy trees can be beneficial for a community. These responses and the actions and the lifestyles and beliefs ensure that people could survive in almost all the wide variety of conditions found across the planet [23].

5. Conclusions

Heat warnings are typically based on outdoor conditions, where the people usually consume little time, especially during the hottest periods or the periods when the warnings are issued. Our conclusions on seasonal heat stress levels in low-income homes show a true picture of actual conditions in the urban residential environments of most of the South Asian cities. Poor communities are most affected because they live in crowded, built-up urban neighborhoods, which are hot and humid, and not equipped with air conditioners. Discomfort levels in low-income houses can be further lessened with some economic and efficient management practices, including using natural ventilation, roof and wall insulation, and shading houses with trees. The use of evaporative coolers, smart and/or high roof and wall with cross-ventilation options can dramatically reduce indoor temperatures and sufferings of the people. Caution may, therefore, be practiced when using passive cooling techniques. Since a substantial fraction of homes exceeds heat thresholds during the extreme events in Faisalabad, there is an immediate need for greater understanding and monitoring of urban heat in cities at risk of heat stress. The findings of this study are also applicable to the people of low-income areas of other parts of the country, such as Lahore and Rawalpindi, that resemble the conditions of Faisalabad. These people may face severe discomfort, due to arid to semiarid climatic conditions where temperature plays a major role in heat stress thresholds. In addition to taking typical custom measures, including taking showers, spending summer nights outside in lawns or on the rooftops, and remaining under the shades during summer days, planting trees in an area can be beneficial for the community in addition to building open community parks with an abundance of greenery and occupancy of thick-canopy trees.

Author Contributions

Conceptualization, F.A., M.I. and B.A.; methodology, F.A., M.I. and S.E.; software, S.E. and F.A.; validation, F.A. and A.A.F.; formal analysis, S.E. and F.A.; investigation, F.A., M.I. and S.E.; resources, F.A. and B.A.; data curation, S.E.; Writing—Original draft preparation, S.E., F.A. and M.I.; Writing—Review and editing, B.A. and A.A.F.; supervision, F.A. and M.I.; project administration, F.A. and B.A.; funding acquisition, F.A., B.A. and A.A.F. All authors have read and agreed to the published version of the manuscript.

Funding

This research was partially funded by (i) the Higher Education Commission of Pakistan under the title of “Heat stress in slums and congested areas of Faisalabad city”, grant number NO.5632/PUNJAB/NRPU/R$D/HEC/2016, (ii) the Himalayan Adaptation, Water and Resilience (HI-AWARE) consortium supported by the Collaborative Adaptation Research Initiative in Africa and Asia (CARIAA), and (iii) the Natural Sciences and Engineering Research Council of Canada (NSERC).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

This study did not report any data.

Acknowledgments

Sana Ehsan sincerely expresses her gratitude to the Higher Education Commission of Pakistan for providing her financial support to complete the Ph.D. program. Help from the climate change research group of the Government College University Faisalabad namely Muhammad Adrees, Usman Iftikhar, Musaab Waqas, Muhammad Awais, and Qurat ul An Aini is acknowledged. The authors are thankful to Christian Siderius (Wageningen University) for his continuous support during this work.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. IPCC. Fourth Assessment Report. Geneva, Intergovernmental Panel on Climate Change; Cambridge University Press: Cambridge, UK, 2018. [Google Scholar]
  2. Moser, C.; Satterthwaite, D. Toward pro-poor adaptation to climate change in the urban centers of low-and middle-income countries. In Social Dimensions of Climate Change: Equity and Vulnerability in a Warming World; World Bank: Washington, DC, USA, 2010; pp. 231–258. [Google Scholar]
  3. Hijioka, Y.; Lin, E.; Pereira, J.; Corlett, R.; Cui, X.; Insarov, G.; Lasco, R.; Lindgren, E.; Surjan, A. Climate Change 2014: Impacts, Adaptation, and Vulnerability. Part B: Regional Aspects. Contribution of Working Group II to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change; Cambridge University Press: Cambridge, UK, 2014. [Google Scholar]
  4. Hajat, S.; Kosatky, T. Heat-related mortality: A review and exploration of heterogeneity. J. Epidemiol. Community Health 2010, 64, 753–760. [Google Scholar] [CrossRef]
  5. Baccini, M.; Biggeri, A.; Accetta, G.; Kosatsky, T.; Katsouyanni, K.; Analitis, A.; Anderson, H.R.; Bisanti, L.; D’Ippoliti, D.; Danova, J.; et al. Heat effects on mortality in 15 European cities. Epidemiology 2008, 19, 711–719. [Google Scholar] [CrossRef]
  6. Shah, S.A.A.; Solangi, Y.A. A sustainable solution for electricity crisis in Pakistan: Opportunities, barriers, and policy implications for 100% renewable energy. Environ. Sci. Pollut. Res. 2019, 26, 29687–29703. [Google Scholar] [CrossRef]
  7. Oke, T.R. The energetic basis of the urban heat island. Q. J. R. Meteorol. Soc. 1982, 108, 1–24. [Google Scholar]
  8. Harlan, S.L.; Declet-Barreto, J.H.; Stefanov, W.L.; Petitti, D.B. Neighborhood effects on heat deaths: Social and environmental predictors of vulnerability in Maricopa County, Arizona. Environ. Health Perspect. 2013, 121, 197–204. [Google Scholar] [CrossRef] [Green Version]
  9. Smargiassi, A.; Fournier, M.; Griot, C.; Baudouin, Y.; Kosatsky, T. Prediction of the indoor temperatures of an urban area with an in-time regression mapping approach. J. Expo. Sci. Environ. Epidemiol. 2018, 18, 282–288. [Google Scholar] [CrossRef] [Green Version]
  10. Traci, L. Sustainable Climate Design. Ph.D. Dissertation, The University of Arizona, Tucson, AZ, USA, 2018. [Google Scholar]
  11. Alcazar, S.S.; Olivieri, F.; Neila, J. Green roofs: Experimental and analytical study of its potential for urban microclimate regulation in Mediterranean–continental climates. Urban Clim. 2016, 17, 304–317. [Google Scholar] [CrossRef]
  12. Sánchez, C.S.G.; Peiró, M.N.; González, F.J.N. Urban heat island and vulnerable population. The case of Madrid. In Sustainable Development and Renovation in Architecture, Urbanism and Engineering; Springer: Cham, Switzerland, 2017; pp. 3–13. [Google Scholar]
  13. Paul, R.K. Thermal Responses in Peri-urban Environment: A Case Study of Baduria Municipality in North Parganas, West Bengal. Observer 2018, 55, 75–83. [Google Scholar]
  14. Lechner, N. Heating, Cooling, Lighting. In Sustainable Design Methods for Architects, 4th ed.; John Wiley & Sons: New York, NY, USA, 2015. [Google Scholar]
  15. Saleem, S.G.; Ansari, T.; Ali, A.S.; Fatima, S.; Rizvi, M.H.; Samad, M.A. Risk factors for heat related deaths during the June 2015 heat wave in Karachi, Pakistan. J. Ayub Med Coll. Abbottabad 2017, 29, 320–324. [Google Scholar] [PubMed]
  16. Collins, M.; Knutti, R.; Arblaster, J.; Dufresne, J.-L.; Fichefet, T.; Friedlingstein, P.; Gao, X.; Gutowski, W.J.; Johns, T.; Krinner, G.; et al. Long-term climate change: Projections, commitments and irreversibility. In Climate Change 2013—The Physical Science Basis. Contribution of Working Group I to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change; Stocker, T.F., Qin, D., Plattner, G.-K., Tignor, M., Allen, S.K., Boschung, J., Nauels, A., Xia, X., Bex, V., Midgley, P.M., Eds.; Cambridge University Press: Cambridge, UK; New York, NY, USA, 2013. [Google Scholar]
  17. Nazaroff, W.W. Four principles for achieving good indoor air quality. Indoor Air 2013, 23, 353–356. [Google Scholar] [CrossRef] [PubMed]
  18. Linares, C.; Díaz, J.; Negev, M.; Martínez, G.S.; Debono, R.; Paz, S. Impacts of climate change on the public health of the Mediterranean Basin population-current situation, projections, preparedness and adaptation. Environ. Res. 2020, 182, 109107. [Google Scholar] [CrossRef]
  19. Conti, S.; Meli, P.; Minelli, G.; Solimini, R.; Toccaceli, V.; Vichi, M.; Beltrano, C.; Perini, L. Epidemiologic study of mortality during the Summer 2003 heat wave in Italy. Environ. Res. 2005, 98, 390–399. [Google Scholar] [CrossRef]
  20. Gabriel, K.M.A.; Endlicher, W.R. Urban and rural mortality rates during heat waves in Berlin and Brandenburg, Germany. Environ. Pollut. 2011, 159, 2044–2050. [Google Scholar] [CrossRef]
  21. Okamoto-Mizuno, K.; Mizuno, K. Effects of thermal environment on sleep and circadian rhythm. J. Physiol. Anthropol. 2012, 31, 14. [Google Scholar] [CrossRef] [Green Version]
  22. Laaidi, K.; Zeghnoun, A.; Dousset, B.; Bretin, P.; Vandentorren, S.; Giraudet, E.; Beaudeau, P. The Impact of Heat Islands on Mortality in Paris during the August 2003 Heat Wave. Environ. Health Perspect. 2012, 120, 254–259. [Google Scholar] [CrossRef] [Green Version]
  23. Nicol, J.F.; Roaf, S. Rethinking thermal comfort. Build. Res. Inf. 2017, 45, 711–716. [Google Scholar] [CrossRef]
  24. Kingma, B.; van Marken Lichtenbelt, W. Energy consumption in buildings and female thermal demand. Nat. Clim. Chang. 2015, 5, 1054–1056. [Google Scholar] [CrossRef]
  25. Pallubinsky, H.; Schellen, L.; Rieswijk, T.A.; Breukel, C.M.G.A.M.; Kingma, B.R.M.; van Marken Lichtenbelt, W.D. Local cooling in a warm environment. Energy Build. 2016, 113, 15–22. [Google Scholar] [CrossRef]
  26. Van Marken Lichtenbelt, W.; Hanssen, M.; Pallubinsky, H.; Kingma, B.; Schellen, L. Healthy excursions outside the thermal comfort zone. Build. Res. Inf. 2017, 45, 819–827. [Google Scholar] [CrossRef] [Green Version]
  27. Schweiker, M.; Rissetto, R.; Wagner, A. Thermal expectation: Influencing factors and its effect on thermal perception. Energy Build. 2020, 210, 109729. [Google Scholar] [CrossRef]
  28. Masood, I.; Majid, Z.; Sohail, S.; Zia, A.; Raza, S. The deadly heat wave of Pakistan, June 2015. Int. J. Occup. Environ. Med. 2015, 6, 247–248. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  29. Rhomberg, L.R.; Chandalia, J.K.; Long, C.M.; Goodman, J.E. Measurement error in environmental epidemiology and the shape of exposure-response curves. Crit. Rev. Toxicol. 2001, 41, 651–671. [Google Scholar] [CrossRef]
  30. Nguyen, J.L.; Schwartz, J.; Dockery, D.W. The relationship between indoor and outdoor temperature, apparent temperature, relative humidity, and absolute humidity. Indoor Air 2014, 24, 103–112. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  31. Pryor, J.L.; Pryor, R.R.; Grundstein, A.; Casa, D.J. The Heat Strain of Various Athletic Surfaces: A Comparison between Observed and Modeled Wet-Bulb Globe Temperatures. J. Athl. Train. 2017, 52, 1056–1064. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  32. Sohar, E.; Tennenbaum, J.; Robinson, N. A comparison of the Cumulative Discomfort Index (Cum. DI) and Cumulative Effective Temperature (Cum. ET), as obtained by meteorological data. Biometeorol. Pergamon 1962, 395–400. [Google Scholar] [CrossRef]
  33. Ren, Z.; Wang, X.; Chen, D. Heat stress within energy efficient dwellings in Australia. Archit. Sci. Rev. 2014, 57, 227–236. [Google Scholar] [CrossRef]
  34. Thom, E.C. The discomfort index. Weatherwise 1959, 12, 57–61. [Google Scholar] [CrossRef]
  35. Engineering ToolBox. Indoor Comfort Temperature versus Outdoor Temperature. 2006. Available online: https://www.engineeringtoolbox.com/indoor-outdoor-temperature-d_1018.html (accessed on 30 January 2021).
  36. Oreszczyn, T.; Ridley, I.; Hong, S.H.; Wilkinson, P.; Warm Front Study Group. Mould and winter indoor relative humidity in low income households in England. Indoor Built Environ. 2006, 15, 125–135. [Google Scholar] [CrossRef]
  37. Künzel, H.M. Indoor Relative Humidity in Residential Buildings—A Necessary Boundary Condition to Assess the Moisture Performance of Building Envelope Systems. 2015. Available online: https://wufi.de/literatur/K%c3%bcnzel%20-%20Indoor%20Relative%20Humidity%20in%20Residential.pdf (accessed on 3 March 2021).
  38. Quraishi, S.A.; Berra, L.; Nozari, A. Indoor temperature and relative humidity in hospitals: Workplace considerations during the novel coronavirus pandemic. Occup. Environ. Med. 2020, 77, 508. [Google Scholar] [CrossRef]
  39. Log, T. Modeling Indoor Relative Humidity and Wood Moisture Content as a Proxy for Wooden Home Fire Risk. Sensors 2019, 19, 5050. [Google Scholar] [CrossRef] [Green Version]
  40. Bylund, M.C.; Hagentoft, C.E.; Holl, K.; Nik, V.M.; Kilian, R. Simulations of moisture gradients in wood subjected to changes in relative humidity and temperature due to climate change. Geosciences 2018, 8, 378. [Google Scholar]
  41. Rana, R.; Kusy, B.; Jurdak, R.; Wall, J.; Hu, W. Feasibility analysis of using humidex as an indoor thermal comfort predictor. Energy Build. 2013, 64, 17–25. [Google Scholar] [CrossRef]
  42. Armson, D.; Stringer, P.; Ennosa, A.R. The effect of tree shade and grass on surface and globe temperatures in an urban area. Urban For. Urban Green. 2012, 11, 245–255. [Google Scholar] [CrossRef]
  43. Klemm, W.; Heusinkveld, B.G.; Lenzholzer, S.; Hove, B. Street greenery and its physical and psychological impact on thermal comfort. Landsc. Urban Plan. 2015, 138, 87–98. [Google Scholar] [CrossRef]
  44. Pathirana, S.; Rodrigo, A.; Halwatura, R. Effect of building shape, orientation, window to wall ratios and zones on energy efficiency and thermal comfort of naturally ventilated houses in tropical climate. Int. J. Energy Environ. Eng. 2019, 10, 107–120. [Google Scholar] [CrossRef]
  45. Makaka, G.; Meyer, E. Temperature stability of traditional and low-cost modern housing in the Eastern Cape, South Africa. J. Build. Phys. 2006, 30, 71–86. [Google Scholar] [CrossRef]
  46. Mohammad, S.; Shea, A. Performance evaluation of modern building thermal envelope designs in the semi-arid continental climate of Tehran. Buildings 2013, 3, 674–688. [Google Scholar] [CrossRef] [Green Version]
  47. Astrom, C. Commentary: What measure of temperature is the best predictor of mortality? Environ. Res. 2012, 118, 149–151. [Google Scholar]
  48. Givoni, B. Man, Climate and Architecture, 2nd ed.; Applied Science Publishers: London, UK, 1976; pp. 1–144. [Google Scholar]
Figure 1. Meeting of some members of study team with community heads to convince them for attending community awareness seminars in Babuwala and Muradabad sites of this study about the importance of the talk and their participation in the study activities.
Figure 1. Meeting of some members of study team with community heads to convince them for attending community awareness seminars in Babuwala and Muradabad sites of this study about the importance of the talk and their participation in the study activities.
Ijerph 18 02535 g001
Figure 2. The geographic location of Faisalabad city and the five low-income communities (top) the past 50-year record of monthly means for rainfall, minimum temperature, and maximum temperature for the Faisalabad region.
Figure 2. The geographic location of Faisalabad city and the five low-income communities (top) the past 50-year record of monthly means for rainfall, minimum temperature, and maximum temperature for the Faisalabad region.
Ijerph 18 02535 g002
Figure 3. Snapshots of the neighborhood (left) and indoor conditions (right) of (a) Site 1: The clock tower district; (b) Site 2: D block of Gulam-Muhammad Abad; (c) Site 3: Gulam-Muhammad Abad; (d) Site 4: Muradabad; and (e) Site 5: Babuwala.
Figure 3. Snapshots of the neighborhood (left) and indoor conditions (right) of (a) Site 1: The clock tower district; (b) Site 2: D block of Gulam-Muhammad Abad; (c) Site 3: Gulam-Muhammad Abad; (d) Site 4: Muradabad; and (e) Site 5: Babuwala.
Ijerph 18 02535 g003
Figure 4. Relationships between (a) indoor wet-bulb and outdoor dry-bulb temperatures drawn from the data of the Engineering ToolBox [35], and (b) between the observed outdoor wet-bulb and outdoor dry-bulb temperatures.
Figure 4. Relationships between (a) indoor wet-bulb and outdoor dry-bulb temperatures drawn from the data of the Engineering ToolBox [35], and (b) between the observed outdoor wet-bulb and outdoor dry-bulb temperatures.
Ijerph 18 02535 g004
Figure 5. Diurnal wet-bulb temperature, dry-bulb temperature, and discomfort indices for (a) indoor (b) outdoor, and (c) comparison of indoor and outdoor diurnal discomfort indices, and (d) monthly averages of daily mean temperatures (plotted on the primary y-axis) and cumulative monthly rainfall (plotted on the secondary y-axis) for the study period.
Figure 5. Diurnal wet-bulb temperature, dry-bulb temperature, and discomfort indices for (a) indoor (b) outdoor, and (c) comparison of indoor and outdoor diurnal discomfort indices, and (d) monthly averages of daily mean temperatures (plotted on the primary y-axis) and cumulative monthly rainfall (plotted on the secondary y-axis) for the study period.
Ijerph 18 02535 g005
Figure 6. Variations in the monthly averaged discomfort indices caused by increasing and/or decreasing dry- and wet-bulb temperatures of the indoor day, night (a,c), and outdoor day, night (b,d) conditions during the five months of summer 2016.
Figure 6. Variations in the monthly averaged discomfort indices caused by increasing and/or decreasing dry- and wet-bulb temperatures of the indoor day, night (a,c), and outdoor day, night (b,d) conditions during the five months of summer 2016.
Ijerph 18 02535 g006
Figure 7. Discomfort indices for the days of the highest discomfort index month (May 2016) of the study period based on the effects of house building design concepts, including (a) houses exposed to sunlight versus shaded houses, and (b) houses with and without proper ventilation.
Figure 7. Discomfort indices for the days of the highest discomfort index month (May 2016) of the study period based on the effects of house building design concepts, including (a) houses exposed to sunlight versus shaded houses, and (b) houses with and without proper ventilation.
Ijerph 18 02535 g007
Figure 8. Diurnal effect of the house building design concepts in terms of discomfort indices for 23 May 2016, when people faced the highest discomfort level during summer 2016 under the scenarios of (a) houses exposed to sunlight versus shaded houses, and (b) houses with and without proper ventilation.
Figure 8. Diurnal effect of the house building design concepts in terms of discomfort indices for 23 May 2016, when people faced the highest discomfort level during summer 2016 under the scenarios of (a) houses exposed to sunlight versus shaded houses, and (b) houses with and without proper ventilation.
Ijerph 18 02535 g008
Table 1. Description of variables and summary statistics of socio-economic conditions and building design concepts of houses (n = 52) considered in this study.
Table 1. Description of variables and summary statistics of socio-economic conditions and building design concepts of houses (n = 52) considered in this study.
CategoryHouseholds and Building DesignStatistics
Household ratios
Family sizeNumber of dwellers6.6/house
Gender proportionFemale:Male~1.0 (148:144)
Crowding per householdNo rooms/No of occupants0.4 (114/292)
Building design concepts
Rooms with windowsWith61%
Without38%
One window57%
Two windows4%
Rooms with ventsWith50%
Without50%
One vent32%
Two or more vents18%
Rooms with shadesWith89%
Without11%
Fully shaded59%
Partly shaded30%
Necessities
Home appliancesEvaporative water cooler9.6%
Fan100%
Fridge55%
UPS/Generator10%
Own toilet87%
Separate indoor kitchen66%
Washing machine53%
Experience power outage 100%
Table 2. Values of discomfort index calculated from measured indoor dry-bulb temperature (Td) and (a) measured indoor wet-bulb temperature (Tw), (b) indoor Tw calculated with Engineering ToolBox [35] equation (Figure 4a), and (c) indoor Tw calculated with measured outdoor Td-Tw relationship (Figure 4b).
Table 2. Values of discomfort index calculated from measured indoor dry-bulb temperature (Td) and (a) measured indoor wet-bulb temperature (Tw), (b) indoor Tw calculated with Engineering ToolBox [35] equation (Figure 4a), and (c) indoor Tw calculated with measured outdoor Td-Tw relationship (Figure 4b).
Date
dd/mm
a. Discomfort Index from Measured Td and Tw, °Cb. Discomfort Index from Engineering TooBox Equation [35], °Cc. Discomfort Index from Measured Outdoor Td-Tw Relation, °C
01/0428.225.429.9
16/0428.225.229.7
01/0531.528.834.2
16/0529.228.829.7
01/0631.729.434.9
16/0632.129.635.2
01/0731.629.434.9
16/0730.327.632.6
01/0830.927.532.5
15/0830.227.032.0
Minimum, °C28.225.229.7
Maximum, °C32.129.635.2
Mean, °C30.427.932.6
SD, °C1.441.632.24
SD, standard deviation.
Table 3. Age group and gender of the interviewees who were interviewed for their experience about heat-related complaints and mitigation strategies.
Table 3. Age group and gender of the interviewees who were interviewed for their experience about heat-related complaints and mitigation strategies.
GenderAdult: ≥18 Years Old (% of Total Participants)Non-Adult: <18 Years Old (% of Total Participants)Total Participants (%)
Female85 (30.1%)63 (21.6%)148 (50.7%)
Male76 (26.0%)68 (23.3%)144 (49.3%)
Total161 (55.1%)131 (44.9%)292 (100%)
Table 4. Gender-wise (n = 104 @ 2 samples per household) data for heat-related health complaints and heat mitigation strategies adopted by the interviewees.
Table 4. Gender-wise (n = 104 @ 2 samples per household) data for heat-related health complaints and heat mitigation strategies adopted by the interviewees.
Health ComplaintsPercentHeat Mitigation StrategiesPercent
MaleFemaleAll *MaleFemaleTotal
Dehydration16.9814.8915.9Drank more water21.2813.2117.25
Diarrhea26.4217.0221.7Drank water and took a shower14.895.6610.28
Eye infection4.262.13Drank water and rested14.899.4312.16
Fever24.5323.424.0Moved to cooler places10.6418.8714.8
Flu (runny nose)1.896.384.14Took more than usual rest10.647.559.10
Headache16.9827.6622.3Took multiple showers a day21.2841.5131.4
Nosebleed1.896.384.14Took shower and stayed home6.383.775.08
Muscular fatigue1.890.95Did not know what to do
Skin allergy5.662.83Did not know what to do
Mild temperature2.771.39Did not know what to do
* percentage calculated based on all genders’ data.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Ehsan, S.; Abbas, F.; Ibrahim, M.; Ahmad, B.; Farooque, A.A. Thermal Discomfort Levels, Building Design Concepts, and Some Heat Mitigation Strategies in Low-Income Communities of a South Asian City. Int. J. Environ. Res. Public Health 2021, 18, 2535. https://doi.org/10.3390/ijerph18052535

AMA Style

Ehsan S, Abbas F, Ibrahim M, Ahmad B, Farooque AA. Thermal Discomfort Levels, Building Design Concepts, and Some Heat Mitigation Strategies in Low-Income Communities of a South Asian City. International Journal of Environmental Research and Public Health. 2021; 18(5):2535. https://doi.org/10.3390/ijerph18052535

Chicago/Turabian Style

Ehsan, Sana, Farhat Abbas, Muhammad Ibrahim, Bashir Ahmad, and Aitazaz A. Farooque. 2021. "Thermal Discomfort Levels, Building Design Concepts, and Some Heat Mitigation Strategies in Low-Income Communities of a South Asian City" International Journal of Environmental Research and Public Health 18, no. 5: 2535. https://doi.org/10.3390/ijerph18052535

APA Style

Ehsan, S., Abbas, F., Ibrahim, M., Ahmad, B., & Farooque, A. A. (2021). Thermal Discomfort Levels, Building Design Concepts, and Some Heat Mitigation Strategies in Low-Income Communities of a South Asian City. International Journal of Environmental Research and Public Health, 18(5), 2535. https://doi.org/10.3390/ijerph18052535

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop