Next Article in Journal
Serologic Status of Borrelia burgdorferi sensu lato in Patients with Cardiovascular Changes
Next Article in Special Issue
Match Running Performance Profile and Heart Rate Response in Amputee Soccer Players
Previous Article in Journal
Psychometric Analysis of an Academic Self-Attribution Questionnaire in Middle and High School Students in Italy: Implications of Gender and Age
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Brief Report

Test-Retest Reliability and Minimum Difference Values of a Novel and Portable Upright Row Strength Assessment in Probation Officers

by
Nicholas A. Buoncristiani
1,2,3,
Jacob A. Mota
4,
Gena R. Gerstner
1,2,
Hayden K. Giuliani-Dewig
5 and
Eric D. Ryan
1,2,3,*
1
Neuromuscular Assessment Laboratory, Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
2
Carolina Center for Healthy Work Design and Worker Well-Being, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
3
Human Movement Science Curriculum, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
4
Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX 79430, USA
5
Human Performance Innovation Center, Rockefeller Neuroscience Institute, West Virginia University, Morgantown, WV 26505, USA
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2023, 20(3), 2236; https://doi.org/10.3390/ijerph20032236
Submission received: 16 November 2022 / Revised: 17 January 2023 / Accepted: 25 January 2023 / Published: 27 January 2023
(This article belongs to the Special Issue Editorial Board Members' Collection Series: Exercise Physiology)

Abstract

:
Upper body (UB) strength is important for occupational tasks and injury prevention in law enforcement officers (LEOs). Portable, reliable, and cost-effective assessments are needed to examine UB strength among LEOs in field settings. The purpose of this study was to examine the test-retest reliability and minimum difference (MD) values of a novel and portable isometric upright row assessment in probation officers. Thirty certified probation officers (18 women; age = 38.9 ± 9.0 years, body mass = 98.8 ± 27.1 kg, stature = 171.4 ± 14.0 cm) volunteered for this investigation. Testing occurred on-site across two sessions (2–5 days apart). Participants stood upon an aluminum plate with a chain attached to a handle and dynamometer. They grasped the handle with a pronated grip, two cm below the umbilicus, and performed three isometric maximal voluntary contractions. Intraclass correlation coefficient (ICC2,1), standard error of the measurement (SEM), and MD values were calculated. Results indicated no significant systematic error (p = 0.080) across sessions. The ICC2,1, SEM, and MD values for UB strength were 0.984, 27.20 N (4.1% of the mean), and 75.38 N (11.3% of the mean), respectively. These data suggest this isometric upright row assessment is a reliable, portable, and cost-effective measure of UB strength to assess and monitor LEOs in field settings.

1. Introduction

Law enforcement officers (LEOs) are essential public safety personnel, with occupational tasks that include high physical and psychological demands [1,2]. As of 2020, there were nearly 800,000 LEOs employed in the United States, with an expected increase of nearly 10 percent by 2030 [3]. The unpredictable nature of this occupation requires sudden transitions from sedentary activity (i.e., driving, paperwork), to tasks that require high-physical demand (i.e., foot pursuit and suspect apprehension) [2,4]. Due to the high physiological stress and hazardous nature of this occupation, LEOs have an injury rate of nearly 500 per 10,000 workers, which is over four times the national average (107.1 per 10,000), resulting in a large financial burden [5,6].
Previous investigations have noted that upper body (UB) strength is an important factor impacting occupational performance and injury risk [7,8]. For example, the primary critical job tasks for LEOs include maneuvering over fences, subduing and controlling suspects, and transporting victims or offenders, all of which require some degree of UB strength [1]. Previous studies have found low isometric strength to be associated with poorer performance during simulated occupational tasks and shooting accuracy in LEOs and recruits [7,8]. In addition, low isometric UB strength (i.e., grip strength) has also been shown to be associated with a greater injury risk in LEO recruits [8].
The most common laboratory assessment of UB strength is typically performed using isokinetic dynamometry [9,10]. However, due to its cost and lack of portability, investigators have utilized handheld dynamometry (HHD) to assess muscular strength in field and clinical settings [9,10]. Previous studies [11,12] have noted a lack of standardization of participant placement and evaluator positioning, and dependence on evaluator strength as key HDD weaknesses that may impact its consistency, especially when examining larger muscle groups. Given the importance of UB strength in LEOs, future studies are needed to identify reliable, portable, and cost-effective UB multi-joint strength assessments. Further, the determination of minimum difference (MD) values may be important for researchers and LEO administrators to determine if a difference or change in UB strength can be considered real [13]. Thus, the purpose of this study is to examine the test-retest reliability and MD values of a novel and portable isometric upright row assessment in probation officers, a subset of LEOs. We chose to use a validated, commercially available dynamometer [14] during a common bilateral, easy-to-perform UB exercise, often prescribed in resistance exercise programs [15].

2. Materials and Methods

2.1. Participants

Thirty certified probation officers (18 women; all demographic data are in Table 1) volunteered for this investigation. Before testing, all participants completed and signed an approved consent form, and completed a health history questionnaire. None of the participants reported any current neuromuscular or metabolic diseases, or musculoskeletal injuries sustained within the previous three months that would preclude them from participating in the testing. In addition, none of the participants were involved in an active workers’ compensation or personal injury case, or were trying to become pregnant. This study was approved by the University’s Institutional Review Board (#16–3295) and all participants were informed of the benefits and risks of the investigation prior to signing an institutionally-approved informed consent document to participate in this study.

2.2. Experimental Design

This study used a repeated-measures design to examine the test-retest reliability of a novel UB isometric assessment among probation officers. Testing occurred across two separate sessions that were scheduled 2–5 days apart and were completed at the same time of the day (± three hours). All testing occurred on-site at local probation-officer offices in North Carolina.

2.3. Isometric Strength Testing

Upper-body isometric strength testing occurred on a custom-built, portable, aluminum plate (which the participants stood on), that included a tension dynamometer (TSD121C, BIOPAC Systems Inc., Goleta, CA) attached in series with a metal chain and handle (Figure 1). Participants grasped the handle with a pronated grip, approximately shoulder-width apart. The length of the chain was adjusted so that the handle was approximately two cm below the umbilicus for each participant and kept the same for each testing session. Following a brief warm-up consisting of three submaximal isometric contractions (50–75% of perceived maximal exertion) lasting four seconds, participants then performed three isometric maximal voluntary contractions (MVC), with a 2-minute rest period between attempts. Participants were initially instructed to pull the bar sub-maximally to remove the slack in the chain immediately prior to the start of the MVC, as determined with visual feedback of force production. Once the baseline force was completely steady, participants were given strong verbal encouragement to pull as hard and as fast as possible during each contraction for 3–4 s.

2.4. Signal Processing

Force (N) was sampled at 2KHz with a Biopac data acquisition system (MP150WSW, Biopac Systems Inc., Goleta, CA, USA) and stored on a personal computer (ThinkPad T420; Lenovo, Morrisville, NC, USA). Custom-written software (LabVIEW 17; National Instruments, Austin, TX, USA) was used to process all the signals offline. Signals were filtered with a zero-phase shift, fourth order, low-pass Butterworth filter (150 Hz) [16]. Peak force for the MVCs was defined as the highest 500 ms epoch during the plateau of the MVC.

2.5. Statistical Analysis

Test-retest reliability for UB isometric strength was evaluated using the procedures described by Weir [13] and analyzed using a custom-written software program (Microsoft Excel, Microsoft, Redmond, WA, USA). A one-way repeated-measures analyses of variance (ANOVAs) were used to examine the systematic variability across testing days. The intraclass correlation coefficient (ICC) was calculated from model ‘2,1’, as described by Shrout and Fleiss [17], because it has been suggested that the ICCs generated with this model can be generalized to other research laboratories conducting field-based assessments. Further, the standard error of measurement (SEM) and MD values were calculated based on the recommendations of Weir [13], using the mean square error term from the ANOVA, and expressed as a percentage of the mean. Alpha levels were set a priori at 0.05 to determine statistical significance.

3. Results

Our participant demographics are similar to and representative of probation officers in the state of North Carolina [18]. There was no significant systematic error (p = 0.080) between day 1 (658.50 ± 228.14 N) and day 2 (671.25 ± 217.70 N) UB strength values. The ICC2,1, SEM, and MD values for UB strength were 0.984, 27.20 N (4.1% of the mean), and 75.38 N (11.3% of the mean), respectively.

4. Discussion

The findings of the present study indicated no significant systematic error across testing sessions and acceptable relative (ICC2,1 = 0.984) and absolute (SEM = 27.2 N, SEM% = 4.1%) consistency values. To the authors’ knowledge, this is the first study to assess the test-retest reliability of a portable UB isometric upright row strength assessment in first responders. Previous papers have examined the test-retest reliability of various portable UB assessments, ranging from “make” or “break” HHD, to fixed isometric assessments [9,10,11]. Of these, previous work utilizing isometric assessments to examine UB strength have reported similar test-retest reliability. For example, Holt et al. [9] examined the reliability of portable isometric shoulder strength assessments, which resulted in similar relative (ICC = 0.91–0.96) and absolute (SEM = 2.21–3.87 Nm, SEM% = 7.13–9.59%) values when compared to our novel strength assessment.
From a practitioner perspective, the MD values from this study suggest a change of at least 75.38 N (11.3% of the mean) is needed to be considered a real change in UB isometric upright row strength as a result of an intervention, treatment, or condition, which is similar to the findings reported by Holt et al. [9]. Previous authors [19,20,21] have also examined sex-related differences, training interventions (pre- and post-resistance training), and upper-body injury (participants recovering from radial fracture versus uninjured participants) on UB strength reporting differences of 216 N, 76 N, and 118 N, respectively. Based on the results of our investigation and previous studies, this assessment can reliably detect changes in UB strength seen in common clinical and training scenarios.
It is important to discuss our limitations. The current assessment examined UB isometric strength during an upright row. It is unclear if this setup can be used to examine other specific measures of UB strength (e.g., shoulder flexion, extension) traditionally examined with isokinetic dynamometry.

5. Conclusion and Practical Applications

Previous studies [7,8] have noted that UB muscular strength is critically important for various job-specific occupational tasks and injury prevention. For example, decreased UB strength is associated with failing simulated occupational assessments, poor marksmanship, and injury status in LEOs [8]. For tactical strength and conditioning researchers and practitioners, it is often more feasible to assess UB muscle strength in LEOs at their local offices. Common portable tests that employ HHD are often dependent on the clinician’s strength and experience level, while lacking testing standardization that may impact the usefulness of HHD to assess UB strength [11,12]. Future UB assessments using validated, commercially available equipment are needed to overcome these limitations. The findings from this study demonstrated that the UB isometric upright row is a reliable multi-joint UB muscle strength assessment that is portable, cost-effective, easy to implement, and sensitive to changes commonly seen in many clinical and training situations.

Author Contributions

J.A.M. and E.D.R.; methodology, J.A.M., G.R.G. and E.D.R.; formal analysis, N.A.B., J.A.M., G.R.G., H.K.G.-D. and E.D.R.; investigation, N.A.B., J.A.M., G.R.G., H.K.G.-D. and E.D.R.; data curation, N.A.B., J.A.M., G.R.G., H.K.G.-D. and E.D.R.: writing and original draft preparation, N.A.B., G.R.G. and E.D.R.; writing—review and editing, N.A.B., J.A.M., G.R.G., H.K.G.-D. and E.D.R.; supervision; N.A.B., J.A.M., G.R.G., H.K.G.-D. and E.D.R. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by a research grant from the CDC #U19OH012303 and NIOSH #T42OH008673.

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Institutional Review Board of The University of North Carolina at Chapel Hill (#16-3295).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Deidentified individual data that supports the results will be shared upon a reasonable request beginning 12–24 months following publication, provided the investigator who proposes to use the data has approval from an Institutional Review Board (IRB), Independent Ethics Committee (IEC), or Research Ethics Board (REB), as applicable, and executes a data use/sharing agreement and data management plan with UNC.

Acknowledgments

We would like to thank the North Carolina Department of Public Safety for supporting this project and all the probation officers who participated in this study. We would also like to thank Kaitlyn Newman, Megan McKenna, Luis Freile, and Abigail Trivisonno for their help with data collection.

Conflicts of Interest

The results from the present study do not constitute endorsement of the product by the authors or the IJERPH.

References

  1. Jamnik, V.; Gumienak, R.; Gledhill, N. Developing legally defensible physiological employment standards for prominent physically demanding public safety occupations: A Canadian perspective. Eur. J. Appl. Physiol. 2013, 113, 2447–2457. [Google Scholar] [CrossRef] [PubMed]
  2. Sorensen, L.; Smolander, J.; Louhevaara, V.; Korhonen, O.; Oja, P. Physical Activity, Fitness and Body Composition of Finnish Police Officers: A 15-year Follow-up Study. Occup. Med. 2000, 50, 3–10. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Bureau of Labor Statistics. U.S. Department of Labor, Occupational Outlook Handbook, Police and Detectives. Available online: https://www.bls.gov/ooh/protective-service/police-and-detectives.htm (accessed on 12 August 2022).
  4. Dawes, J.J.; Orr, R.M.; Flores, R.R.; Lockie, R.G.; Kornhauser, C.; Holmes, R. A physical fitness profile of state highway patrol officers by gender and age. Ann. Occup. Environ. Med. 2017, 29, 16. [Google Scholar] [CrossRef] [PubMed]
  5. Bureau of Labor Statistics. Nonfatal Occupational Injuries and Illnesses Requiring Days Away from Work; Bureau of Labor Statistics: Washington, DC, USA, 2014; Volume 31.
  6. Holloway-Beth, A.; Forst, L.; Freels, S.; Brandt-Rauf, S.; Friedman, L. Occupational Injury Surveillance Among Law Enforcement Officers Using Workers’ Compensation Data, Illinois 1980 to 2008. J. Occup. Environ. Med. 2016, 58, 594–600. [Google Scholar] [CrossRef] [PubMed]
  7. Frio Marins, E.; Cabistany, L.; Bartel, C.; Dawes, J.J.; Boscolo Del Vecchio, F. Aerobic fitness, upper-body strength and agility predict performance on an occupational physical ability test among police officers while wearing personal protective equipment. J. Sports Med. Phys. Fit. 2019, 59, 1835–1844. [Google Scholar] [CrossRef] [PubMed]
  8. Orr, R.; Pope, R.; Stierli, M.; Hinton, B. Grip Strength and Its Relationship to Police Recruit Task Performance and Injury Risk: A Retrospective Cohort Study. IJERPH 2017, 14, 941. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  9. Holt, K.L.; Raper, D.P.; Boettcher, C.E.; Waddington, G.S.; Drew, M.K. Hand-held dynamometry strength measures for internal and external rotation demonstrate superior reliability, lower minimal detectable change and higher correlation to isokinetic dynamometry than externally-fixed dynamometry of the shoulder. Phys. Ther. Sport 2016, 21, 75–81. [Google Scholar] [CrossRef] [PubMed]
  10. McLaine, S.J.; Ginn, K.A.; Kitic, C.M.; Fell, J.W.; Bird, M.-L. The Reliability of Strength Tests Performed In Elevated Shoulder Positions Using a Handheld Dynamometer. J. Sport Rehabil. 2016, 1–4. Available online: https://journals.humankinetics.com/view/journals/jsr/25/2/article-jsr.2015-0034.xml.xml (accessed on 5 August 2022). [CrossRef] [PubMed]
  11. Schrama, P.P.M.; Stenneberg, M.S.; Lucas, C.; van Trijffel, E. Intraexaminer Reliability of Hand-Held Dynamometry in the Upper Extremity: A Systematic Review. Arch. Phys. Med. Rehabil. 2014, 95, 2444–2469. [Google Scholar] [CrossRef] [PubMed]
  12. Wikholm, J.B.; Bohannon, R.W. Hand-held Dynamometer Measurements: Tester Strength Makes a Difference. J. Orthop. Sport. Phys. Ther. 1991, 13, 191–198. [Google Scholar] [CrossRef] [PubMed]
  13. Weir, J.P. Quantifying test-retest reliability using the intraclass correlation coeffecient and the SEM. J. Strength Cond. Res. 2005, 10, 231–240. [Google Scholar]
  14. Wiles, J.D.; Boyson, H.; Balmer, J.; Bird, S.R. Validity and reliability of a new isometric hand dynamometer. Sports Eng. 2001, 4, 147–152. [Google Scholar] [CrossRef]
  15. McAllister, M.J.; Schilling, B.K.; Hammond, K.G.; Weiss, L.W.; Farney, T.M. Effect of Grip Width on Electromyographic Activity During the Upright Row. J. Strength Cond. Res. 2013, 27, 181–187. [Google Scholar] [CrossRef] [PubMed]
  16. Thompson, B.J. Influence of signal filtering and sample rate on isometric torque—Time parameters using a traditional isokinetic dynamometer. J. Biomech. 2019, 83, 235–242. [Google Scholar] [CrossRef] [PubMed]
  17. Shrout, P.E.; Fleiss, J.L. Intraclass correlations: Uses in assessing rater reliability. Psychol. Bull. 1979, 86, 420–428. [Google Scholar] [CrossRef] [PubMed]
  18. Mota, J.A.; Kerr, Z.Y.; Gerstner, G.R.; Giuliani, H.K.; Ryan, E.D. Obesity Prevalence and Musculoskeletal Injury History in Probation Officers. Med. Sci. Sports Exerc. 2019, 51, 1860–1865. [Google Scholar] [CrossRef] [PubMed]
  19. Bot, A.G.J.; Mulders, M.A.M.; Fostvedt, S.; Ring, D. Determinants of Grip Strength in Healthy Subjects Compared to That in Patients Recovering From a Distal Radius Fracture. J. Hand Surg. 2012, 37, 1874–1880. [Google Scholar] [CrossRef] [PubMed]
  20. Hunter, S.K.; Enoka, R.M. Sex differences in the fatigability of arm muscles depends on absolute force during isometric contractions. J. Appl. Physiol. 2001, 91, 2686–2694. [Google Scholar] [CrossRef] [PubMed]
  21. Meigh, N.J.; Keogh, J.W.L.; Schram, B.; Hing, W.; Rathbone, E.N. Effects of supervised high-intensity hardstyle kettlebell training on grip strength and health-related physical fitness in insufficiently active older adults: The BELL pragmatic controlled trial. BMC Geriatr. 2022, 22, 354. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Example of the upper body isometric upright row assessment. The handle is placed approximately two centimeters below the umbilicus.
Figure 1. Example of the upper body isometric upright row assessment. The handle is placed approximately two centimeters below the umbilicus.
Ijerph 20 02236 g001
Table 1. Mean ± standard deviation (SD) and range values for the demographic variables.
Table 1. Mean ± standard deviation (SD) and range values for the demographic variables.
Mean ± SDRange
Age (yrs)38.9 ± 9.025.0–55.0
Stature (cm)171.4 ± 14.0154.5–199.1
Body Mass (kg)98.8 ± 27.152.0–185.4
Body Mass Index (kg/m2) 33.2 ± 5.821.1–47.2
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Buoncristiani, N.A.; Mota, J.A.; Gerstner, G.R.; Giuliani-Dewig, H.K.; Ryan, E.D. Test-Retest Reliability and Minimum Difference Values of a Novel and Portable Upright Row Strength Assessment in Probation Officers. Int. J. Environ. Res. Public Health 2023, 20, 2236. https://doi.org/10.3390/ijerph20032236

AMA Style

Buoncristiani NA, Mota JA, Gerstner GR, Giuliani-Dewig HK, Ryan ED. Test-Retest Reliability and Minimum Difference Values of a Novel and Portable Upright Row Strength Assessment in Probation Officers. International Journal of Environmental Research and Public Health. 2023; 20(3):2236. https://doi.org/10.3390/ijerph20032236

Chicago/Turabian Style

Buoncristiani, Nicholas A., Jacob A. Mota, Gena R. Gerstner, Hayden K. Giuliani-Dewig, and Eric D. Ryan. 2023. "Test-Retest Reliability and Minimum Difference Values of a Novel and Portable Upright Row Strength Assessment in Probation Officers" International Journal of Environmental Research and Public Health 20, no. 3: 2236. https://doi.org/10.3390/ijerph20032236

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop