Reducing Unnecessary Biopsies Using Digital Breast Tomosynthesis and Ultrasound in Dense and Nondense Breasts

1
Medical Image Optimisation and Perception Group, Discipline of Medical Imaging Science, Faculty of Medicine and Health, The University of Sydney, Camperdown, NSW 2006, Australia
2
Department of Radiological Sciences, Faculty of Applied Medical Sciences, King Khalid University, Abha 62529, Saudi Arabia
3
Medical Imaging Department, Prince of Wales Hospital, Sydney, NSW 2031, Australia
4
Discipline of Diagnostic Radiography, UGF 12 ASSERT, Brookfield Health Sciences, University College Cork, College Road, T12 AK54 Cork, Ireland
5
Royal Prince Alfred Hospital, Sydney Local Health District, Camperdown, NSW 2050, Australia
6
Orange Radiology, Laboratories and Research Centre, Calabar 540281, Nigeria
*
Author to whom correspondence should be addressed.
Curr. Oncol. 2022, 29(8), 5508-5516; https://doi.org/10.3390/curroncol29080435
Submission received: 21 June 2022 / Revised: 29 July 2022 / Accepted: 2 August 2022 / Published: 4 August 2022
(This article belongs to the Special Issue Breast Cancer Imaging and Therapy)

Abstract

:
Aim: To compare digital breast tomosynthesis (DBT) and ultrasound in women recalled for assessment after a positive screening mammogram and assess the potential for each of these tools to reduce unnecessary biopsies. Methods: This data linkage study included 538 women recalled for assessment from January 2017 to December 2019. The association between the recalled mammographic abnormalities and breast density was analysed using the chi-square independence test. Relative risks and the number of recalled cases requiring DBT and ultrasound assessment to prevent one unnecessary biopsy were compared using the McNemar test. Results: Breast density significantly influenced recall decisions (p < 0.001). Ultrasound showed greater potential to decrease unnecessary biopsies than DBT: in entirely fatty (21% vs. 5%; p = 0.04); scattered fibroglandular (23% vs. 10%; p = 0.003); heterogeneously dense (34% vs. 7%; p < 0.001) and extremely dense (39% vs. 9%; p < 0.001) breasts. The number of benign cases needing assessment to prevent one unnecessary biopsy was significantly lower with ultrasound than DBT in heterogeneously dense (1.8 vs. 7; p < 0.001) and extremely dense (1.9 vs. 5.1; p = 0.03) breasts. Conclusion: Women with dense breasts are more likely to be recalled for assessment and have a false-positive biopsy. Women with dense breasts benefit more from ultrasound assessment than from DBT.

1. Introduction

Early detection of breast cancer is crucial to reducing mortality from the disease [1]. Population screening using mammography is the standard approach to early detection. The principal criterion for screening recommendation is patient age, although a family history of breast cancer is also a well-established risk factor for breast cancer. In the last two decades, high mammographic breast density as a risk factor has also gained significant attention in the literature due to the associated increase in breast cancer risk and the resultant reduced sensitivity of screening mammography [2]. Technological advances and the transition from film-screen to digital mammography (DM) reduced the masking effect of breast density and enhanced cancer detection [3]. However, there are still difficulties reading DM images of women with dense breasts [4]. Mammographically dense tissue has been demonstrated to increase radiologists’ suspicion during the interpretation of screening mammograms, leading to higher recall rates for women with mammographically dense breasts [5].
Most women with dense breasts recalled for assessment have demonstrated negative or benign outcomes, with false positives ranging between 73% and 97% [6,7,8,9,10]. Unnecessary recalls increase the cost of screening, may cause psychosocial harm due to false-positive alarms, and can deter women from rescreening [11,12]. Digital breast tomosynthesis (DBT) and ultrasound can mitigate the limitations associated with DM, allowing for a more detailed evaluation of breast tissue and suspicious lesions by minimising superimposition of parenchymal densities [13,14,15]. In the United Kingdom National Health Service Breast Screening Programme, DBT assessment of women recalled at DM screening led to a 33% reduction in the benign biopsy rate [16], with lower false positives across mammographic features such as mass lesions and asymmetric densities. Some studies have also shown that using ultrasound is accurate in distinguishing between benign and malignant lesions and decreases the number of benign biopsies by 34% to 60% [17,18]. However, it is unclear how DBT and ultrasound compare when assessing women recalled and whether they reduce false-positive biopsies across different breast compositions.
Studies comparing DBT and ultrasound [19,20] have focused on incremental breast cancer detection in mammography-negative dense breasts. In one study [21], the effectiveness of ultrasound screening after the combination of DM and DBT was examined. Despite the widespread concurrent use of DBT and ultrasound in many clinical settings, no study has directly compared their diagnostic efficacy in mammography-recalled women to establish optimised assessment pathways. Importantly, no published work has compared the impact of these tools in reducing unnecessary biopsies of benign lesions, across various breast densities. We hypothesised that DBT and ultrasound result in equal numbers of unnecessary biopsies. Therefore, this study aims to compare the performance of DBT and ultrasound in women recalled for assessment after a positive screening mammogram and to compare the number of unnecessary biopsies in dense and nondense breasts.

2. Materials and Methods

2.1. Study Design and Patient Selection

This is a data linkage study of women recalled for assessment following a suspicious finding on their screening mammogram. Patients were included if they were recalled for assessment after a screening mammogram, had both DBT and ultrasound assessment, and underwent breast biopsy procedures. All screening mammograms of the recalled women were read by two radiologists who interpreted the images independently from each other. Any discrepancies between these two readers were resolved by a third radiologist.
A five-tier grading system was used to describe the findings on screening mammograms based on BreastScreen Australia’s RANZCR breast imaging lesion classification system: grade 1 (normal or no abnormality); grade 2 (benign); grade 3 (indeterminate/equivocal); grade 4 (suspicious); grade 5 (malignant). Each breast was examined using two different mammographic views: the craniocaudal (CC) and the mediolateral oblique (MLO). If more mammography spot views were required, they were obtained. Women whose images were rated 3, 4, or 5 were recalled for assessment using DBT and ultrasound to confirm or rule out breast cancer. A needle biopsy was performed on breast lesions graded 3, 4, or 5 after these imaging assessment tools were assessed. Table 1 shows the baseline characteristics of women recalled for assessment.
Breast density was reported according to the Breast Imaging Reporting and Data System (BI-RADS 5th edition): BI-RADS A: “the breasts are almost entirely fatty”; BI-RADS B: “there are scattered areas of fibroglandular density”; BI-RADS C: “the breasts are heterogeneously dense, which may obscure small masses”; BI-RADS D: “the breasts are extremely dense, which lowers the sensitivity of mammography”.
All DBT images used in this study were acquired using Selenia Dimensions (Hologic Inc.). Real time B-mode and colour doppler were performed using an ACUSON S2000 Ultrasound System (HELX Evolution with Touch Control, Siemens Medical Solutions), equipped with a 12L4 linear array transducer (12–4 MHz). Both DBT and ultrasound assessment results were evaluated according to the RANZCR breast imaging lesion classification scale.

2.2. Statistical Analysis

We compared the performance of DBT and ultrasound in women recalled for assessment after a positive screening mammogram to test the hypothesis that there is no difference between DBT and ultrasound in reducing unnecessary benign biopsies. The comparisons were performed according to breast density (BI-RADS A, B, C, and D). Relative risks at a 95% confidence interval were calculated to establish how DBT and ultrasound decreased the likelihood of an unnecessary biopsy following screening mammography. Using needle biopsy results as the reference standard, the number of cases requiring DBT and ultrasound assessment to prevent one unnecessary biopsy was estimated to determine the likelihood of benefit. The number needed to be assessed is inversely proportional to the risk reduction [1/(absolute risk reduction)]. The ideal screening number would be 1, in which all the women recalled for assessment with benign lesions have benefited. The association between the recalled mammographic abnormalities and breast density was analysed using the chi-square independence test (χ2 continuity correction). The McNemar test (χ2 continuity correction) was used to determine the statistical significance between DBT and ultrasound. A p-value ≤ 0.05 was considered statistically significant. These statistical analyses were conducted via the open-source Jamovi software (2.3.0).

3. Results

The study included 550 mammographic lesions from 538 women, aged 40 to 94 years (mean age: 58.9, SD: ±8.94), recalled at breast cancer screening mammography between 2017 and 2019. Among the 550 lesions recalled, 60.4% were in dense breasts, and 39.6% were in nondense breasts. Breast density was found to influence recall decisions significantly. Mammographic abnormalities were more likely to be recalled when seen in dense breasts than in non-dense breasts (p < 0.001). The distribution of lesion types across dense and nondense breasts is shown in Table 2.
Table 3 shows that there is no difference in true negative proportions between DBT and ultrasound in nondense breasts (32.8% vs. 22%, respectively; p = 0.2). Conversely, in dense breasts, ultrasound showed a significantly higher proportion of true negatives than DBT (54.8% vs. 16.1%, respectively; p < 0.001).
Table 4 shows the potential reduction of unnecessary biopsies for DBT and ultrasound stratified according to breast density. Differences between DBT and ultrasound in terms of preventing one unnecessary biopsy are also presented. Among all recalled mammographic abnormalities, ultrasound showed greater potential to decrease unnecessary biopsies than DBT: entirely fatty (21% vs. 5%, respectively; p = 0.04); scattered fibroglandular (23% vs. 10%, respectively; p = 0.003); heterogeneously dense (34% vs. 7%, respectively; p < 0.001); extremely dense (39% vs. 9%, respectively; p < 0.001) breasts. The number of cases needing assessment to prevent one unnecessary biopsy was significantly lower with ultrasound than with DBT in heterogeneously dense breasts (1.8 vs. 7, respectively; p < 0.001) and extremely dense breasts (1.9 vs. 5.1, respectively; p = 0.03), but there were no significant differences in entirely fatty breasts (3.2 vs. 4.3, respectively; p = 0.65) and scattered fibroglandular densities (2.6 vs. 4.6, respectively; p = 0.21).

4. Discussion

We found strong evidence that the density of a woman’s breast significantly influences recall decisions in a population-based screening program. Mammographic abnormalities were more likely to be recalled when seen in dense breasts than in nondense breasts. We also found that a significant number of the lesions found in women with dense breasts recalled for assessment were benign, and almost double the number of benign lesions recalled in women with nondense breasts. These findings suggest that around 1 in 3 women with dense breasts recalled for assessment had an unnecessary biopsy.
Several factors affect the interpretation of two-dimensional images and may be responsible for the high number of recalls, particularly in women with dense breasts. Summation artefacts caused by the superimposition of dense tissue on benign lesions may mimic breast cancer, which may have resulted in the high rate of unnecessary recalls [15,22]. False-positive or negative recall at screening may be due to perceptual or cognitive errors caused by factors such as poor lesion visibility and subtle or atypical cancer appearances [23]. It has been shown that breast density is more likely to cause perceptual errors such as false positives and negatives due to its ability to obscure subtle lesions or create difficulty in distinguishing lesions in distracting background breast tissue [14,24,25]. Such perceptual errors and the higher of cancer incidence in dense breasts may have contributed to the high recall of women with high breast density.
Mammographic abnormalities such as calcifications, masses with indistinct, spiculated or circumscribed margins, and asymmetries are frequent features of breast cancer [15,22,25]. Mammographic features such as calcifications and discrete masses constituted the largest proportion of benign biopsies. These two mammographic features are common findings in screening programs [26,27,28]. The high false-positive biopsies of these lesion types underscore the need for studies to establish the features of these lesions associated with malignancy to inform criteria for reducing unnecessary recall. Such studies may provide reasonable thresholds for identifying true positive lesions and reduce overtesting and unnecessary biopsies of benign lesions. Another factor that may have been responsible for the higher recall of benign lesions is lesion size. Screening quality can be judged by the detection of small cancers, defined as those with a diameter of ≤15 mm. Small-sized calcifications (≤15 mm) and calcifications that cover a larger region of breast are more likely to be malignant [29,30,31]. However, the diameters of calcifications varied widely in our data. Malignancy may be established by a complex combination of lesion features including size, morphology, and shape. Studies that combine these features to predict malignancy may better inform criteria for recall and biopsy.
A major focus of our study was to examine the potential role of DBT and ultrasound in reducing unnecessary biopsies. Previous pieces of work that compared DBT and ultrasound focused on women with mammographically negative dense breasts [19,20] and showed that ultrasound has a higher false-positive rate than DBT. Our study focuses on women with mammographically suspicious findings recalled for assessment and shows that ultrasound has significantly greater potential to decrease unnecessary biopsies than DBT in all breast compositions. We found no significant difference in true negative proportions between ultrasound and DBT in nondense breasts. In dense breasts, ultrasound showed a significantly higher proportion of true negatives than DBT. We also found that the number of cases that required assessment to prevent one unnecessary biopsy was significantly lower with ultrasound than DBT in heterogeneously dense and extremely dense breasts. These findings suggest that every benign lesion in heterogeneously and extremely dense breasts being unnecessarily recalled has approximately a 50% (1 out of 2 benign lesions) chance of receiving benefit from ultrasound.
In women with nondense breasts, we found no significant difference between DBT and ultrasound in terms of the number of cases that required assessment to prevent one unnecessary biopsy. To the best of our knowledge, the current study was the first to compare DBT and ultrasound assessments of recalled lesions across dense and nondense breasts. Previous studies [15,25] that focused on ultrasound showed that mimickers of breast cancer with benign morphologic ultrasound features could be safely managed with ultrasound follow-up to establish stability and confirm benign status. In dense breasts, ultrasound was found to be a satisfactory alternative to biopsy for solid lesions with benign morphological ultrasound features because of the high negative predictive value (99.8%) [32]; this may reduce anxiety for women recalled for assessment.
Previous studies that sought to reduce unnecessary biopsies were based on DBT. In one of these studies [16] incorporating DBT into the diagnostic workup of mammographic abnormalities would have resulted in a reduction in the number of benign biopsies conducted during screening assessment. The authors reported that DBT enhances reader accuracy and confidence in judging whether mammographic abnormalities are cancerous or not, resulting in a decrease in biopsies from 69% to 36%. However, this study did not adjust for breast density and lesion characteristics. A study from the USA [33] showed that DBT has the potential to decrease unnecessary biopsies for all breast densities, with substantial reductions for women with heterogeneously dense breasts (21.3%) and extremely dense breasts (27.5%). Our study, based on an Australian population and radiologists, showed only modest potential of DBT to reduce unnecessary biopsies for women of all breast compositions: entirely fatty (5%), scattered fibroglandular (10%), heterogeneously dense (7%), and extremely dense breasts (9%). These differences may be due to the differences in study designs and recall classification criteria. Unlike the USA study, we included women recalled for assessment following a suspicious finding on their screening mammograms that were read by two radiologists who worked independently. Additionally, the RANZCR grade 3 used by BreastScreen Australia is classified as a positive finding that combines the BI-RADS 3 and BI-RADS 4A categories in the American College of Radiologists BI-RADS Atlas. These differences may have influenced the impact of DBT during assessment for recalled women.
Although ultrasound is an effective assessment tool to differentiate between benign and malignant lesions that appear suspicious on mammography, it is limited in accurately classifying calcifications. Therefore, mammography-recalled calcifications should not be wholly ruled out based on ultrasound findings. This is supported by a previous study [17] that suggested that women should be recalled for biopsy even if suspicious calcifications are considered normal during an ultrasound. This previous work also showed a decrease in the false-positive rate in screening mammography by incorporating ultrasound into the diagnostic work-up of suspicious findings. However, further studies are needed to estimate the benefit-to-harm ratio and costs of ultrasound and DBT as assessment tools.
Our study is not without limitations. First, it is a single-centre study. Second, the sample size is relatively small, and 60.4% of recalled lesions in our study were in dense breasts, representing a large proportion of recalled mammograms. Thus, a greater understanding of work-up for dense breasts might help screening programs better manage their assessment procedures and resources.

5. Conclusions

The mammographic breast density increases recall rates and biopsy recommendations, and women with dense breasts recalled for assessment are more likely to have a false-positive biopsy compared to those with fatty breasts. In dense breasts, ultrasound showed greater potential to decrease unnecessary biopsies than DBT, with every benign lesion in dense breasts being unnecessarily recalled having approximately a 50% chance of benefiting from ultrasound. DBT and ultrasound perform comparatively similar in reducing unnecessary benign biopsies in fatty breasts. Therefore, tailoring assessment pathways according to breast density may reduce unnecessary biopsies and anxiety in women recalled for assessment.

Author Contributions

Conceptualization, I.H., M.M. and E.E.; methodology, I.H. and E.E.; validation, I.H., E.E., M.M., J.C., W.R. and W.V.; analysis, I.H.; investigation, I.H. and E.E.; data collection, I.H.; writing—original draft preparation, I.H.; writing—review and editing, I.H., E.E., M.M., J.C., W.R. and W.V.; supervision, E.E. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki, and received ethics approval from the New South Wales health department (IRB: X19-0495) and local approval from Sydney Local Health District (2019/ETH13792), date of approval: 11 February 2020.

Informed Consent Statement

The Committee granted a waiver of the usual requirement for the consent of the individual for the use of their health information in a research project, in accordance with the Health Records and Information Privacy Act 2002 (NSW) and the NSW Privacy Commissioner’s Statutory guidelines on research and the NHMRC Guidelines approved under Section 95A of the Privacy Act 1988.

Data Availability Statement

Data are available from the authors with the permission of BreastScreen NSW, Sydney Local Health District.

Acknowledgments

We want to thank Beby Thung Winata for assisting with data collection.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Nelson, H.D.; Tyne, K.; Naik, A.; Bougatsos, C.; Chan, B.K.; Humphrey, L.; U.S. Preventive Services Task Force. Screening for breast cancer: An update for the U.S. Preventive Services Task Force. Ann. Intern Med. 2009, 151, 727–737. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Bond-Smith, D.; Stone, J. Methodological Challenges and Updated Findings from a Meta-analysis of the Association between Mammographic Density and Breast Cancer. Cancer Epidemiol. Biomark. Prev. 2019, 28, 22–31. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Kerlikowske, K.; Hubbard, R.A.; Miglioretti, D.L.; Geller, B.M.; Yankaskas, B.C.; Lehman, C.D.; Taplin, S.H.; Sickles, E.A.; Breast Cancer Surveillance Consortium. Comparative effectiveness of digital versus film-screen mammography in community practice in the United States: A cohort study. Ann. Intern Med. 2011, 155, 493–502. [Google Scholar] [CrossRef]
  4. Posso, M.; Louro, J.; Sánchez, M.; Román, M.; Vidal, C.; Sala, M.; Baré, M.; Castells, X. Mammographic breast density: How it affects performance indicators in screening programmes? Eur. J. Radiol. 2019, 110, 81–87. [Google Scholar] [CrossRef]
  5. Ekpo, E.U.B.; Egbe, N.O.P.; Egom, A.E.B.; McEntee, M.F.P. Mammographic Breast Density: Comparison Across Women with Conclusive and Inconclusive Mammography Reports. J. Med. Imaging Radiat. Sci. 2015, 47, 55–59. [Google Scholar] [CrossRef] [PubMed]
  6. Hong, S.; Song, S.Y.; Park, B.; Suh, M.; Choi, K.S.; Jung, S.E.; Kim, M.J.; Lee, E.H.; Lee, C.W.; Jun, J.K. Effect of Digital Mammography for Breast Cancer Screening: A Comparative Study of More than 8 Million Korean Women. Radiology 2020, 294, 247–255. [Google Scholar] [CrossRef] [PubMed]
  7. Berg, W.A.; Zhang, Z.; Lehrer, D.; Jong, R.A.; Pisano, E.D.; Barr, R.G.; Böhm-Vélez, M.; Mahoney, M.C.; Evans, W.P.; Larsen, L.H. Detection of breast cancer with addition of annual screening ultrasound or a single screening MRI to mammography in women with elevated breast cancer risk. JAMA 2012, 307, 1394–1404. [Google Scholar]
  8. Pisano, E.D.; Hendrick, R.E.; Yaffe, M.J.; Baum, J.K.; Acharyya, S.; Cormack, J.B.; Hanna, L.A.; Conant, E.F.; Fajardo, L.L.; Bassett, L.W.; et al. Diagnostic Accuracy of Digital versus Film Mammography: Exploratory Analysis of Selected Population Subgroups in DMIST. Radiology 2008, 246, 376–383. [Google Scholar] [CrossRef] [Green Version]
  9. McDonald, E.S.; McCarthy, A.M.; Akhtar, A.L.; Synnestvedt, M.B.; Schnall, M.; Conant, E.F. Baseline screening mammography: Performance of full-field digital mammography versus digital breast tomosynthesis. Am. J. Roentgenol. 2015, 205, 1143–1148. [Google Scholar] [CrossRef]
  10. Gilbert, F.J.; Tucker, L.; Gillan, M.G.C.; Willsher, P.; Cooke, J.; Duncan, K.A.; Michell, M.J.; Dobson, H.M.; Lim, Y.Y.; Suaris, T.; et al. Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial). Radiology 2015, 277, 697–706. [Google Scholar] [CrossRef]
  11. Brewer, N.T.; Salz, T.; Lillie, S.E. Systematic review: The long-term effects of false-positive mammograms. Ann. Intern Med. 2007, 146, 502–510. [Google Scholar] [CrossRef]
  12. Zappa, M.; Spagnolo, G.; Ciatto, S.; Giorgi, D.; Paci, E.; Rosseli del Turco, M. Measurement of the costs in two mammographic screening programmes in the province of Florence, Italy. J. Med. Screen 1995, 2, 191–194. [Google Scholar] [CrossRef] [PubMed]
  13. Peppard, H.R.; Nicholson, B.E.; Rochman, C.M.; Merchant, J.K.; Mayo, R.C., III; Harvey, J.A. Digital Breast Tomosynthesis in the Diagnostic Setting: Indications and Clinical Applications. RadioGraphics 2015, 35, 975–990. [Google Scholar] [CrossRef] [PubMed]
  14. Rafferty, E.A. Digital Mammography: Novel Applications. Radiol. Clin. N. Am. 2007, 45, 831–843. [Google Scholar] [CrossRef] [PubMed]
  15. Guirguis, M.S.; Adrada, B.; Santiago, L.; Candelaria, R.; Arribas, E. Mimickers of breast malignancy: Imaging findings, pathologic concordance and clinical management. Insights Imaging 2021, 12, 53. [Google Scholar] [CrossRef]
  16. Sharma, N.; McMahon, M.; Haigh, I.; Chen, Y.; Dall, B.J.G. The Potential Impact of Digital Breast Tomosynthesis on the Benign Biopsy Rate in Women Recalled within the UK Breast Screening Programme. Radiology 2019, 291, 310–317. [Google Scholar] [CrossRef] [PubMed]
  17. Tohno, E.; Umemoto, T.; Sasaki, K.; Morishima, I.; Ueno, E. Effect of adding screening ultrasonography to screening mammography on patient recall and cancer detection rates: A retrospective study in Japan. Eur. J. Radiol. 2013, 82, 1227–1230. [Google Scholar] [CrossRef]
  18. Stavros, A.T.; Thickman, D.; Rapp, C.L.; Dennis, M.A.; Parker, S.H.; Sisney, G.A. Solid breast nodules: Use of sonography to distinguish between benign and malignant lesions. Radiology 1995, 196, 123–134. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  19. Tagliafico, A.S.; Calabrese, M.; Mariscotti, G.; Durando, M.; Tosto, S.; Monetti, F.; Airaldi, S.; Bignotti, B.; Nori, J.; Bagni, A.; et al. Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts: Interim Report of a Prospective Comparative Trial. J. Clin. Oncol. 2016, 34, 1882–1888. [Google Scholar] [CrossRef]
  20. Tagliafico, A.S.; Mariscotti, G.; Valdora, F.; Durando, M.; Nori, J.; La Forgia, D.; Rosenberg, I.; Caumo, F.; Gandolfo, N.; Sormani, M.P. A prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2). Eur. J. Cancer 2018, 104, 39–46. [Google Scholar] [CrossRef]
  21. Yi, A.; Jang, M.J.; Yim, D.; Kwon, B.R.; Shin, S.U.; Chang, J.M. Addition of Screening Breast US to Digital Mammography and Digital Breast Tomosynthesis for Breast Cancer Screening in Women at Average Risk. Radiology 2021, 298, 568–575. [Google Scholar] [CrossRef] [PubMed]
  22. Castells, X.; Torá-Rocamora, I.; Posso, M.; Román, M.; Vernet-Tomas, M.; Rodríguez-Arana, A.; Domingo, L.; Vidal, C.; Baré, M.; Ferrer, J.; et al. Risk of Breast Cancer in Women with False-Positive Results according to Mammographic Features. Radiology 2016, 280, 379–386. [Google Scholar] [CrossRef] [PubMed]
  23. Ekpo, E.U.; Alakhras, M.; Brennan, P. Errors in Mammography Cannot be Solved Through Technology Alone. Asian Pac. J. Cancer Prev. 2018, 19, 291–301. [Google Scholar] [CrossRef]
  24. Corsetti, V.; Houssami, N.; Ghirardi, M.; Ferrari, A.; Speziani, M.; Bellarosa, S.; Remida, G.; Gasparotti, C.; Galligioni, E.; Ciatto, S. Evidence of the effect of adjunct ultrasound screening in women with mammography-negative dense breasts: Interval breast cancers at 1year follow-up. Eur. J. Cancer 2011, 47, 1021–1026. [Google Scholar] [CrossRef]
  25. Nassar, L.; Baassiri, A.; Salah, F.; Barakat, A.; Najem, E.; Boulos, F.; Berjawi, G. Stromal Fibrosis of the Breast: A Spectrum of Benign to Malignant Imaging Appearances. Radiol. Res. Pract. 2019, 2019, 5045908. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  26. Farshid, G.; Sullivan, T.; Downey, P.; Gill, P.G.; Pieterse, S. Independent predictors of breast malignancy in screen-detected microcalcifications: Biopsy results in 2545 cases. Br. J. Cancer 2011, 105, 1669–1675. [Google Scholar] [CrossRef] [Green Version]
  27. Stomper, P.C. The prevalence and distribution of well circumscribed nodules on screening mammography: Analysis of 1500 mammograms. Breast Dis. 1991, 4, 197–203. [Google Scholar]
  28. Farshid, G.; Walker, A.; Battersby, G.; Sullivan, T.; Gill, P.G.; Pieterse, S.; Downey, P. Predictors of malignancy in screen-detected breast masses with indeterminate/equivocal (grade 3) imaging features. Breast 2011, 20, 56–61. [Google Scholar] [CrossRef]
  29. Fondrinier, E.; Lorimier, G.; Guerin-Boblet, V.; Bertrand, A.-F.; Mayras, C.; Dauver, N. Breast Microcalcifications: Multivariate Analysis of Radiologicand Clinical Factors for Carcinoma. World J. Surg. 2002, 26, 290–296. [Google Scholar] [CrossRef] [PubMed]
  30. James, J.J.; Evans, A.J.; Pinder, S.E.; Macmillan, R.D.; Wilson, A.R.M.; Ellis, I.O. Is the Presence of Mammographic Comedo Calcification Really a Prognostic Factor for Small Screen-detected Invasive Breast Cancers? Clin. Radiol. 2003, 58, 54–62. [Google Scholar] [CrossRef]
  31. Nyante, S.J.; Lee, S.S.; Benefield, T.S.; Hoots, T.N.; Henderson, L.M. The association between mammographic calcifications and breast cancer prognostic factors in a population-based registry cohort. Cancer 2017, 123, 219–227. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  32. Graf, O.; Helbich, T.H.; Hopf, G.; Graf, C.; Sickles, E.A. Probably Benign Breast Masses at US: Is Follow-up an Acceptable Alternative to Biopsy? Radiology 2007, 244, 87–93. [Google Scholar] [CrossRef] [PubMed]
  33. Richard, E.; Sharpe, J.; Venkataraman, S.; Phillips, J.; Dialani, V.; Fein-Zachary, V.J.; Prakash, S.; Slanetz, P.J.; Mehta, T.S. Increased Cancer Detection Rate and Variations in the Recall Rate Resulting from Implementation of 3D Digital Breast Tomosynthesis into a Population-based Screening Program. Radiology 2016, 278, 698–706. [Google Scholar] [CrossRef]
Table 1. Characteristics of women recalled for assessment following a suspicious mammography finding.
Table 1. Characteristics of women recalled for assessment following a suspicious mammography finding.
CharacteristicNo. (%)
Age (years)
40–49 69 (12.8)
50–59 222 (41.2)
60–69 163 (30.3)
≥70 84 (15.7)
Breast Density
Almost entirely fatty 64 (12)
Scattered areas of fibroglandular density 152 (28.2)
Heterogeneously dense 238 (44.2)
Extremely dense 84 (15.6)
Risk Factor of Breast Cancer (Personal/Family History)
Yes 98 (18.2)
No 440 (81.8)
Table 2. Association between recall and breast density based on lesion features.
Table 2. Association between recall and breast density based on lesion features.
Breast Density
Radiologic FeatureNondense Breasts (Number of Benign Lesions)Dense Breasts (Number of Benign Lesions)Totalp-Value
NSD26 (16)23 (10)49<0.001
Stellate51 (5)75 (7)126
Calcification39 (18)128 (53)167
Discrete mass99 (32)82 (44)181
Architectural distortion3 (2)24 (10)27
Total218 (73)332 (124)550
NSD: Nonspecific density; Nondense Breasts: almost entirely fatty & scattered areas of fibroglandular density; Dense Breasts: heterogeneously dense & extremely dense; Bold values indicate statistical significance at the p-value ≤ 0.05 level.
Table 3. True negative proportions of DBT and ultrasound across dense and nondense breasts.
Table 3. True negative proportions of DBT and ultrasound across dense and nondense breasts.
NO. of True
Negative (%)
Negative
Outcome (Biopsy)
p-ValueNO. of True
Negative (%)
Negative
Outcome (Biopsy)
p-Value
Breast Density
Assessment ToolsNondense Breasts Dense Breasts
DBT16 (22)730.220 (16.1)124<0.001
US24 (32.8)7368 (54.8)124
Nondense Breasts: almost entirely fatty & scattered areas of fibroglandular density; Dense Breasts: heterogeneously dense & extremely dense; DBT: digital breast tomosynthesis; US: ultrasound; Bold values indicate statistical significance at the p-value ≤ 0.05 level.
Table 4. The potential reduction of DBT and ultrasound to decrease unnecessary biopsies following screening mammography and the number of DBT and ultrasound examinations required to be assessed to prevent one unnecessary biopsy.
Table 4. The potential reduction of DBT and ultrasound to decrease unnecessary biopsies following screening mammography and the number of DBT and ultrasound examinations required to be assessed to prevent one unnecessary biopsy.
Potential Reduction of DBT and Ultrasound to Decrease Unnecessary Biopsies after DM Estimation Number of Benign Cases that Required Assessment by DBT and Ultrasound to Prevent One Unnecessary Biopsy
ParameterRelative Risk (95% CI) NO. of Cases (ARR%)
Breast DensityDBTUSp-ValueDBTUSp-Value
BI-RADS A0.95 (0.89 to 1)0.79 (0.70 to 0.90)0.044.3 (23)3.2 (30.7)0.65
BI-RADS B0.9 (0.85 to 0.95)0.77 (0.70 to 0.84)0.0034.6 (21.7)2.6 (66.7)0.21
BI-RADS C0.93 (0.89 to 0.96)0.66 (0.60 to 0.73)<0.0017 (14.1)1.8 (55.4)<0.001
BI-RADS D0.91 (0.85 to 0.97)0.61 (0.51 to 0.72)<0.0015.1 (18.8)1.9 (50)0.03
BI-RADS A: almost entirely fatty; BI-RADS B: scattered areas of fibroglandular density; BI-RADS C: heterogeneously dense; BI-RADS D: extremely dense; DM: digital mammography; DBT: digital breast tomosynthesis; US: ultrasound; ARR: absolute risk reduction. Bold values indicate statistical significance at the p-value ≤ 0.05 level.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Hadadi, I.; Clarke, J.; Rae, W.; McEntee, M.; Vincent, W.; Ekpo, E. Reducing Unnecessary Biopsies Using Digital Breast Tomosynthesis and Ultrasound in Dense and Nondense Breasts. Curr. Oncol. 2022, 29, 5508-5516. https://doi.org/10.3390/curroncol29080435

AMA Style

Hadadi I, Clarke J, Rae W, McEntee M, Vincent W, Ekpo E. Reducing Unnecessary Biopsies Using Digital Breast Tomosynthesis and Ultrasound in Dense and Nondense Breasts. Current Oncology. 2022; 29(8):5508-5516. https://doi.org/10.3390/curroncol29080435

Chicago/Turabian Style

Hadadi, Ibrahim, Jillian Clarke, William Rae, Mark McEntee, Wendy Vincent, and Ernest Ekpo. 2022. "Reducing Unnecessary Biopsies Using Digital Breast Tomosynthesis and Ultrasound in Dense and Nondense Breasts" Current Oncology 29, no. 8: 5508-5516. https://doi.org/10.3390/curroncol29080435

APA Style

Hadadi, I., Clarke, J., Rae, W., McEntee, M., Vincent, W., & Ekpo, E. (2022). Reducing Unnecessary Biopsies Using Digital Breast Tomosynthesis and Ultrasound in Dense and Nondense Breasts. Current Oncology, 29(8), 5508-5516. https://doi.org/10.3390/curroncol29080435

Article Metrics

Back to TopTop