Next Article in Journal
Convex Programming and Bootstrap Sensitivity for Optimized Electricity Bill in Healthcare Buildings under a Time-Of-Use Pricing Scheme
Previous Article in Journal
Impact of Demand Response Programs on Optimal Operation of Multi-Microgrid System
 
 
Reply published on 7 June 2018, see Energies 2018, 11(6), 1494.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Comment

Comments to Paper Entitled: Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy. Energies 2018, 11, 407

1
School of Civil Engineering and Architecture, Wuhan University of Technology, Wuhan 430070, China
2
College of Engineering and Science, Victoria University, Melbourne 8001, Australia
*
Author to whom correspondence should be addressed.
Energies 2018, 11(6), 1453; https://doi.org/10.3390/en11061453
Submission received: 15 March 2018 / Accepted: 22 May 2018 / Published: 4 June 2018
I have read, with interest, the article authorized by Hong and Kim, which was published in Energies 2018, 11, 407; doi:10.3390/en11020407: entitled “Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy” [1]. I have some concerns about their study approach.
The first concern is that the authors selected outside air temperature, supply air temperature, return air temperature, mixed air temperature, and time related variables as inputs to the models. However, the authors neglected that there is a supply air temperature (SAT) set point, which is conventionally based on outside air temperature [2], which is also the current best practice as proposed by ASHRAE GPC 36. The optimized SAT set point could also be a function of outside air temperature, outside air relative humidity, outdoor air flow rate and supply air flow rate [3], outside air temperature, minimum reheat valve position or return air temperature [4], outside air temperature, load ratio and power exponents [5], outside air temperature and total number of people [2], energy cost signal, and cooling demand [6]. If properly tuned, the SAT should be able to meet its set point. However, the SAT set point reset strategy in this paper is missing.
The second concern is that this paper aims at predicting SAT for energy conservation, however, the energy consumption under different SAT reset strategies is missing.
In order to find optimal SAT control for energy conservation purpose, data mining on the association various SAT controls and related energy consumption is needed.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Hong, G.; Kim, B.S. Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy. Energies 2018, 11, 407. [Google Scholar] [CrossRef]
  2. Gruber, M.; Trüschel, A.; Dalenbäck, J.-O. Alternative strategies for supply air temperature control in office buildings. Energy Build. 2014, 82, 406–415. [Google Scholar] [CrossRef]
  3. Ke, Y.; Mumma, S.A. Optimized supply-air temperature (SAT) in variable-air-volume (VAV) systems. Energy 1997, 22, 601–614. [Google Scholar] [CrossRef]
  4. Liu, M.; Claridge, D.E.; Turner, W.D. Continuous commissioning SM guidebook: maximizing building energy efficiency and comfort. In Federal Energy Management Program; U.S. Department of Energy: Washington, DC, USA, 2002. [Google Scholar]
  5. Wang, G.; Song, L. Air handling unit supply air temperature optimal control during economizer cycles. Energy Build. 2012, 49, 310–316. [Google Scholar] [CrossRef]
  6. Raftery, P.; Li, S.; Jin, B.; Ting, M.; Paliaga, G.; Cheng, H. Evaluation of a cost-responsive supply air temperature reset strategy in an office building. Energy Build. 2018, 158, 356–370. [Google Scholar] [CrossRef] [Green Version]

Share and Cite

MDPI and ACS Style

Lin, Y.; Yang, W. Comments to Paper Entitled: Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy. Energies 2018, 11, 407. Energies 2018, 11, 1453. https://doi.org/10.3390/en11061453

AMA Style

Lin Y, Yang W. Comments to Paper Entitled: Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy. Energies 2018, 11, 407. Energies. 2018; 11(6):1453. https://doi.org/10.3390/en11061453

Chicago/Turabian Style

Lin, Yaolin, and Wei Yang. 2018. "Comments to Paper Entitled: Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy. Energies 2018, 11, 407" Energies 11, no. 6: 1453. https://doi.org/10.3390/en11061453

APA Style

Lin, Y., & Yang, W. (2018). Comments to Paper Entitled: Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy. Energies 2018, 11, 407. Energies, 11(6), 1453. https://doi.org/10.3390/en11061453

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop