An Experimental Data-Driven Model of a Micro-Cogeneration Installation for Time-Domain Simulation and System Analysis

Department of Power Engineering and Turbomachinery, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland
*
Author to whom correspondence should be addressed.
Energies 2020, 13(11), 2759; https://doi.org/10.3390/en13112759
Submission received: 21 April 2020 / Revised: 25 May 2020 / Accepted: 26 May 2020 / Published: 1 June 2020
(This article belongs to the Section G: Energy and Buildings)

Abstract

:
In this article, an investigation of a free-piston Stirling engine-based micro-cogeneration (μCHP) unit is presented. This work is a step towards making the system calculations more reliable, based on a data-driven model, which enables the time-domain simulation of the μCHP behavior. A laboratory setup was developed that allowed for the measurement of a micro-cogeneration unit during long-term operation with a variable thermal load. The maximum efficiency of electricity generation was equal to 13.2% and the highest overall efficiency was equal to 95.7%. A model of the analyzed μCHP system was developed and validated. The simulation model was based on the device’s characteristics that were obtained from the measurements; it enables time-domain calculations, taking into account the different operating modes of the device. The validation of the system showed satisfactory compliance of the model with the measurements: for the period modeled of 24 h, the error in the heat generation fluctuated in the range 0.31–4.50%, the error in the electricity generation was in the range 2.48–4.70%, the error in the natural gas consumption was in the range 0.26–4.59%, and the engine’s runtime error was in the range 0.14–8.58%. The modelling process is easily applicable to other energy systems for detailed analysis.

1. Introduction

Low-stack emission reduction can be implemented by using sources of lower emissions in dwellings (e.g., gas boilers) or renewable sources. The need to increase the share of renewable and distributed energy sources in the production structure, enforced by laws introduced by the European Union, will cause an increase in the interest in such technologies at the local level. Obtaining the required share of renewable energy in total production and reducing pollutant emissions will take place through the implementation of new technologies as well as the modernization of current technological resources, but also through support for distributed energy, in particular, prosumer systems. The use of renewable sources, widely promoted by the EU for many years, is the future of energy production, but it poses significant challenges, which include, first of all, a high investment cost and the discontinuous nature of energy production.
Therefore, for renewable energy to become a reliable source of energy, in addition to the need to reduce costs, it is necessary to:
-
develop energy storage techniques that will allow, among other things, the load in the daily and seasonal cycles resulting from variable demand to be balanced,
-
integrate them with a stable, low-emission source that will flexibly adapt to often unstable renewable sources using optimal operating strategies (e.g., a micro-cogeneration natural gas-fueled system).
Micro-cogeneration is a type of cogeneration, i.e., the simultaneous production of electricity and heat. The prefix “micro” has been interpreted differently, for example Directive 2012/27/EU of the European Parliament and of the Council on energy efficiency [1] describes a micro-cogeneration unit as a system with a maximum electrical power of below 50 kW. However, in the scientific literature, much lower limit values are encountered, e.g., 15 kW [2,3,4] or 5 kW [5,6]. The systematics of micro-cogeneration systems are complex; they can be distinguished according to the type of fuel (natural gas, biomass), the maximum electrical power or the type of use (residential buildings, public buildings). However, the basic criterion for micro-cogeneration (μCHP) system classification is the prime mover. Therefore, a differentiation is made between micro-cogenerators using internal combustion engines [2], organic Rankine cycle (ORC) systems [2,4], gas microturbines [6], and Stirling engines or fuel cells [7]. The scope of this work focused on the use of a micro-cogenerator with a free piston Stirling engine (FPSE). A detailed description of FPSE can be found in the literature [8]. The next subsection presents a brief review of previous research on Stirling engine-based cogenerators.

1.1. Review of Stirling μCHP Research

Research on Stirling engines has intensified exceptionally over the past decade. There are numerous examples in the experimental research, aimed mainly at determining the efficiency potential [9,10] or modeling studies describing the Stirling cycle [11,12]. A separate category is papers concerning free piston engines [13,14,15], which take into account the engines kinematics; in general, these papers focus on the engine itself. There are also examples of using dedicated software (e.g., Sage) for simulation FPSEs [16,17]. An innovative modeling approach has been presented in paper [16]. Researchers implemented a thermoacoustic theory to simulate the micro-cogeneration system based on a free piston Stirling engine. The simulation process was complemented with an experimental study, which revealed the primary deviation within 10%. The combined heat and power (CHP) system only included the engine and it supplied over 6.3 kW of thermal power at mean water temperature of 60 °C. The obtained electric power was 2.9 kW with an overall thermal efficiency of 87.5%. The comprehensive approach for the design of the FPSE for cogeneration purposes was presented in paper [17]. Sage software was used for performance mapping, and the main components of the designed engine were manufactured and examined. The designed engine was meant to operate at 60 Hz due to integration with a preexisting linear alternator and the proximity of the power grid frequency, however the performance mapping of the system was performed within the range of 50–70 Hz. A review of the research conducted on engine modeling, together with its own proposition of model analysis, was described in detail by the authors of article [18]. An interesting viewpoint has been presented by papers related to the potential applications of the engine for larger power systems, usually supplied with biomass [19,20,21,22].
The analytical approach is different when the μCHP device is considered. There have been some experimental studies, including experimental data [23,24,25], and modeling-based papers [7,26,27,28,29,30,31], where dynamic analysis software has been applied.
The field tests of the Whispergen Mk IV have been presented in the literature [24]. The μCHP system (1 kW of electrical power and 7 kW of thermal power) is equipped with a four-cylinder Stirling engine; the unit is powered by natural gas. The tests of the system when operating in a single-family house allowed for a 20.8% reduction in the electricity purchased from the grid. The annual overall efficiency of the system was 86.3%, while the manufacturer’s stated efficiency was 90%. An important result of the research was the availability of the system for 97% of the time throughout the year. The field data of the Whispergen device was also used for modeling [32]. The proposed solution seems to be able to be used for the selected demand profile, however, it does not include cooperation with the heat buffer or external control system. Significant work regarding micro-cogeneration modelling has been presented within IEA/ECBCS Annex 42 [33]. The main outcome is the zero-order modeling approach related to fuel cell and combustion-based μCHP devices [34]. The models omit the physical phenomena and rely on engine-specific parametric equations; it has to be calibrated using experimental data [35]. Its empirical nature makes it applicable for only one device when calibrated. In the case of the Stirling engine, the Whispergen SE data was used [36].
Significant research has been demonstrated [23], where a model of the μCHP gas system with a Stirling engine has been prepared, which was validated by the measurement data. The researchers noticed a significant difference in the approach to modeling, focusing on the proper mapping of the Stirling cycle, and the simulations of buildings equipped with energy generators. Detailed models of the engine did not answer the questions posed in the system analysis and energy assessment of prosumer systems. The prepared model contains transient states of the engine; however, it does not take into account the control system and power modulation of the system.
Important experimental tests have been described in [25]. The researcher performed an analysis of a micro-cogeneration unit (a Stirling engine with nominal parameters of 1 kWel and 5 kWth and peak boiler power of 18 kWth) in real conditions. Although this type of analysis is burdened by situations that are important for the measurement results, such as holidays and power blackouts, it provided valuable data on the efficiency of the μCHP system. For the selected reference measurement, which lasted 1 h (including start-up and shutdown), the efficiency of electricity production was 12.2%, and the total efficiency was 88.5%. In the case of longer, stable work, the authors achieved a total efficiency of about 91%. Efficiencies have been given in relation to the lower calorific value of natural gas. During the described field tests, two modes of operation of the analyzed unit were determined: 0.65 and 0.8 kWel net.
One example of the use of software for dynamic building simulations is a publication in the literature [37], the authors of which used the TRNSYS environment to calculate the seasonal efficiency of a micro-cogeneration unit, based on the data provided by Baxi. The calculation effect indicated that a reduction in the carbon dioxide emissions was achieved through the use of the μCHP. The system efficiency was maintained at a very similar level, regardless of the unit’s operating mode.
A paper in the literature [38] presented the concept of using the μCHP system for a combined customer (a multi-family building and an office building), which resulted in an increase in the system’s operating time compared to the conventional customer profile, and thus better results with regard to the energy and economic contexts. The researchers pointed out that the key to the proper application of micro-cogeneration is the heat demand profile. For well-insulated buildings with a lower ratio of heat demand to electrical power, a micro-generator based on a gas piston engine was indicated to be more suitable than the variant with a Stirling engine. The same team of authors [39] performed an analysis of a prosumer who uses an electric car and charges it using the μCHP (charging station power of 3.3 kW). The possibility of charging a vehicle overnight significantly increased the level of self-consumption. Charging a vehicle for approximately 7.5 h made it possible to cover an average of 120 km in a day. It should be emphasized, however, that the calculations concerned only the heating season in which it is possible to use heat from the Stirling engine.

1.2. Operation Strategies for μCHP Units

Profiles of energy demand in buildings are highly variable. The changing load forces the adaptation of the device supplying the power. A way to prevent peaks in the load is to use energy buffers. However, building heat storage systems have limited capacities, hence there is a need to adjust the power of the energy device. In micro-cogeneration systems, the Stirling engine is an energy generator that usually operates in a two-state, on–off mode, or with a small number of available operating modes.
The general operating strategy is crucial for the optimal effectiveness of the unit, both economic and ecological. Cogeneration units usually operate in two basic modes [40,41]:
  • following the thermal load (FTL, heat tracking), where the maximum possible part of the heat demand is covered by the CHP system, and any deficits are covered by another source. Electricity is an additional product: in the case of overproduction, it is fed back into the grid, and if the demand is higher, electricity is bought from the electricity grid to cover the deficit,
  • following the electrical load (FEL, electricity tracking), when the most important criterion is the maximum possible coverage (by the CHP system) of the electricity demand and the deficits in the electrical energy production are covered by the grid. If there is too much heat generated, it is dissipated and any deficits are covered by another source.
There are some operational strategies where the objective functions are related to the economic or ecological effects, however they are, in actuality, a combination of the basic modes, including switching the device off. In the case of systems other than micro scale, operation without the cogeneration is also considered—electricity is generated and all the heat is dissipated. A paper in the literature [42] presented the least-cost mode (LC), which minimizes the cost of covering both heat and electricity demand in full by the cogeneration system.
There are also strategies which integrate model predictive control to search for the most appropriate operation mode [42,43]. The methods of optimal switching between different modes or optimal power modulation for the CHP unit have been the subject of extensive analysis in the literature. The analyses applied various mathematical approaches, e.g., fuzzy logic, and were related to the μCHP based on fuel cells [44], microturbines [45] or the integration of photovoltaic/thermal (PVT) modules with a heat pump [46]. A fairly common approach to the system analysis of micro-cogeneration is to assume that the μCHP unit operation is in the on–off mode once or twice per day (only using the daily energy balances) [26,47,48,49] or applying power modulation to the device within a certain range, e.g., 0–100% [41,50] or 50–100% [51].

1.3. Motivation and Novelties of Current Work

It was postulated that the assessment of the system implementation of micro-cogeneration units should take into account the operational characteristics and limitations of real systems. It is reasonable to conduct experimental research that allows for the full performance characteristics of micro-cogeneration systems to be determined, and apply it in the modeling, which takes into account the various constraints and better reflects the operation of the unit, which means that the system analysis will have a smaller error. The analyses of energy systems based on a Stirling engine presented in the literature are a good starting point. They have raised a variety of issues which concern system analysis. This work is a step towards making the system calculations more reliable, thanks to the data-driven model. Moreover, a much smaller time step has been used here, which will allow sudden changes in energy demand to be taken into consideration.
The main novelty of the research presented in this paper lies in a contribution to the time-domain modeling of a micro-cogeneration device. The μCHP can be the basis of the prosumer system. The model was developed on the basis of a detailed experimental investigation under a variable thermal load. The research tasks that were performed led to reliable results in the long-term analysis of the prosumer system operation, e.g., by the year or by the heating season. The purpose of the paper is also to present the modeling process, which is applicable for other energy devices in residential scale providing satisfactory results. The results can provide information allowing economic evaluation for given type of consumer.
The paper consists of six sections. Section 2 presents the laboratory installation and measuring equipment used in the experimental work. Section 3 describes, in detail, the results of conducted measurements. The investigated characteristics of micro-cogeneration device are presented. Section 4 presents the developed model of the installation, including the assumptions and equations used for simulations. Section 5 is focused on the model validation. This part presents the applicability of the model and consistency with the experimental results. Section 6 presents the most important outcomes and the conclusions that can be drawn from conducted research. The last part shows also the possible directions for further investigation.

2. Experimental Setup

The laboratory apparatus was based on the Viessmann Vitotwin μCHP unit. It is fueled with natural gas and consists of a condensation gas boiler with a built-in free piston Stirling engine, which is the product of Microgen [52]. This engine has been implemented in multiple micro-cogeneration devices, e.g., Viessmann Vitotwin, Baxi Ecogen, Remeha eVita. It is characterized by the following parameters: maximum electrical power: 1 kW, working gas: helium, nominal pressure 23 bar, nominal voltage: 230 V, frequency: 50 Hz, weight (without a burner): 49 kg, dimensions (without a burner): 450 mm in height, 300 mm in diameter, noise at a distance of 1 m without a housing: 52.5 dB, in a standard housing: 45 dB, declared service life: 50,000 h, hermetically sealed and maintenance free.
The free piston Stirling engine is supplied with heat by a ring-shaped basic burner. This burner is a source of thermal energy for the engine and it covers the basic heat demand. The burner of an auxiliary boiler (for covering the peak load) is a cylindrical radiant burner. The maximum power of the μCHP device is 26 kW of thermal power and 1 kW of gross electrical power. Figure 1 presents the scheme of the research installation, including characteristic points measured during the investigation. The laboratory stand was described in detail in the literature [53] and the following description is mostly based on the aforementioned paper.
From the figure: Ti—temperatures—measured by a thermocouple, TDQi, TRQi, VQi—delivery temperature, return temperature and water flow from the heat meter (i = 1 the first circuit μCHP-heat buffer, i = 2 the second circuit: heat buffer-fan heaters), E—bidirectional electrical energy meter, Pump1—internal μCHP unit pump, Pump2—additional pump for the second circuit, obci—fan heaters.
The laboratory installation consists of: a water heat buffer with a capacity of 750 dm3; a water treatment station Aquahome; and two fan heaters Leo Flowair with nominal powers of 46.8 kW and 8.9 kW (for the delivery and return water parameters TDQ2/TRQ2 = 90 °C/70 °C). The fan heaters allow for the dispersion of the heat generated in the μCHP device. The laboratory apparatus allows for the operation of the Vitotwin module to be observed for various ambient conditions and to determine the characteristics of the device without interfering with its internal control system [53]. The external system for measuring and control allows for archiving the results of the measurements of the temperature, water flows, and natural gas consumption. It consists of:
-
eleven temperature sensors Pt100, error ±5 K;
-
two heat meters B-meters Hydrocal-2, accuracy class: 3 (Directive 2004/22/EC);
-
three water meters GSD5 (for verification), accuracy class: R100 (EN 14154);
-
gas meter BK-G4M, accuracy class: 1.5 (Directive 2004/22/EC);
-
bidirectional electricity meter SBC ALE3, accuracy class: B (EN 50 470-3); the produced electrical energy is supplied to the electricity grid.
The system also allows the rotational speed of the fans in the heaters to be adjusted in the range of 0–100%. This is convenient for precise control of the heat demand. The system allows the water outlet for simulating the hot water consumption to be activated. Also, as the internal, weather controller of the μCHP unit is based on heating curves, the ambient temperature has to be adjustable. In order to control the ambient temperature, a Peltier module-based system was developed (the temperature sensor of the μCHP unit is cooled by the Peltier module, and the regulator operates with on–off control). The main feature of the presented control and measurement system is its ability to execute a predetermined operation schedule for the devices. The schedule consists of the number of measurement cycles and, for each cycle, the rotational speed of the heater fans (range: 0–100%), the ambient temperature (T5z), and the water sluice from the tank (binary: 0% or 100%) [53].
The set of measured data is archived every ten minutes (τmeas = 10 min). In the case of the counting devices (gas, electricity, heat, and water meters), the current state of the meter is archived. The determined values of the thermal power, electrical power, or efficiencies are the average values for 10-min periods. The efficiency values presented in this paper are related to the lower calorific value of the fuel at LHVgas = 35 MJ/m3n. This methodology was previously described in paper [53].
It is important to mention that this study significantly increased the studied range of the device’s power. Multiple heating curves were investigated, as it was necessary to provide full information for the modeling process. The experimental determination of the thermal power was improved, which allowed for the thermodynamic effectiveness of the micro-cogeneration unit to be studied better.

3. Results of the Measurements

The purpose of the measurements was to determine the operational characteristics of the μCHP unit at various heat demands to improve the mathematical modeling of the device.
The following is the nomenclature of the experimentally determined parameters of the μCHP unit, following the installation description in the previous section:
  • TRQ1—temperature of the return water °C;
  • TDQ1—temperature of the delivery water, °C;
  • T5—ambient temperature (simulated for controller), °C;
  • Q(Q1)—thermal power of the μCHP unit (heat generation), kW;
  • Q(Q2)—total thermal power of the fan heaters (simulated heat demand), kW;
  • Ech—chemical energy of the natural gas, kW;
  • Nel_n—net electrical power, kW.
Measurements of the micro-cogeneration system were carried out for three heating curves with different slopes, marked as K1, K2 and K3. The results of the K1 and K3 series of measurements are presented in Figure 2, Figure 3, Figure 4, Figure 5, Figure 6 and Figure 7, respectively. Due to the concise form of this publication (article), it was decided to only graphically present two series with extreme slopes of the heating curve.
Figure 2 presents the recorded values of the delivery/return water temperature and the ambient temperature for the K1 heating curve. In the wide range of the ambient temperature that was tested, from −15 °C to 15 °C, relatively small differences in the supply temperature were obtained; this means that the slope of the K1 curve is shallow. The temperature range below 40 °C allowed for the thermal powers shown in Figure 3 to be achieved. The possibilities of heat dissipation were controlled by the air temperature in the room which had a large volume, in which the fan coolers were located, therefore the thermal power demand Q(Q2) did not exceed 5 kWth. The same figure shows the heat output generated in the μCHP Q(Q1).
It is clear that the system could match the demand well, but it worked on an on–off basis. Figure 4 shows the thermal and electrical power as well as the chemical energy stream used by the μCHP system. When the unit worked in cogeneration, the heat demand was covered by the Stirling engine operating at partial load. The system operation was stable; only one mode of the system was active throughout the entire testing period.
The highest TDQ1 temperature values were obtained for a series of measurements of the K3 heating curve. In this case, starting at an ambient (outside) temperature of T5 = 0 °C, the system worked at the highest possible water delivery temperature, i.e., TDQ1 = 78 °C. The range of the tested temperature T5 was from −15 °C to 13 °C (Figure 5). Figure 6 shows the device’s adaptation to the heat demand that exceeded 13.5 kWth. In addition to the Stirling engine, the peak burner was started, which allowed for a smooth adjustment to the heat demand above approximately 10.5 kWth.
An analysis of Figure 7 indicates that the operation of the unit with a thermal power above the level enabled by the Stirling engine with the peak burner at its minimum load (in total above about 10.5 kWth) can be defined as one mode with modulated thermal power. Below this level, it can be seen that the system, due to the presence of a heat accumulator in the installation, did not have to adjust the power to the current demand, it only regulated the heat production by enabling/disabling the individual modes and the operating time of a particular mode. When the heat demand exceeded the heat production capacity of the Stirling engine (about 5.8 kWth), the peak burner started, although it worked with a low (basic) load.
One of the elements that controls the operation of the micro-cogeneration device are the aforementioned heating curves K, i.e., the relationship between the ambient temperature and the water delivery temperature. Figure 8 shows the TDQ1 temperature value as the T5 = Tamb function, which reflects the waveforms of the analyzed curves that were implemented in the device controller.

Determination of Operating States

The measurements made it possible to determine the parameters of the conditions of stable operation at various heat loads. The described operational states were characterized by different thermal powers, electrical powers, the use of chemical energy of the fuel and the efficiency of energy production. Each of the operating states was determined for a five-hour operation of the micro-cogeneration unit at a constant power, and the presented power values, Nel_n(av), Q(Q1)(av), and Ech(av), were determined as the average values of 30 measurement points during the five hours of operation, in accordance with the general relationship expressed by the Equation (1). Each of the measurement points is an average value for a 10-min period, which resulted from the use of measurement devices to measure the flow of the media (as described in Section 2).
X ( a v ) = j = 1 30 X j 30
where, X:
  • N el _ n —net electrical power at the working point, kW,
  • Q ( Q 1 ) —thermal power at the working point, kW,
  • E ch —chemical energy flux at the working point, kW.
For each operating state, the efficiency of electricity generation ηel_av, heat generation ηq_av and the overall efficiency ηel+q_av were also determined in accordance with the following relationships:
η el _ av = N el _ n ( av ) E ch ( av )
η q _ av = Q ( Q 1 ) ( av ) E ch ( av )
η el + q _ OM 1 = N el _ n ( av ) + Q ( Q 1 ) ( av ) E ch ( av )
Two operating states of the Stirling engine can be distinguished: partial load (SP1) and maximum load (SP2). In the case of operation of a cogeneration unit with thermal power above the production capacity of the Stirling engine, two further operating modes can be generally distinguished: SP3—operation with a power of approximately 10.5 kWth (Stirling engine + peak burner with a basic load) and SP4—work with heat power above 10.5 kWth, when the power is smoothly modulated due to the peak burner. The periods of stable operation in these modes are presented on the basis of time periods. The operation of the micro-cogeneration unit in the SP4 state, i.e., with smoothly modulated thermal power, can be described in detail in two points: for a thermal power of 13.7 kWth (SP4.1) and 16.68 kWth (SP4.2). A summary of the parameters of all operating modes is presented in Table 1. An example of the characteristics for one operating state (SP2) is shown in Figure 9. For the other modes, they were determined analogously to the presented variant.
The SP1 mode is the mode of operation with the lowest possible heat output; however, due to it mainly starting at low operating temperatures of the system, it is characterized by high efficiency. The average water flow rate in the first circuit during the five hours of operation is Vav = 0.197 dm3/s (709.4 dm3/h). The device operates with a small difference in supply/return temperatures (average ∆Tav = 5.6 K).
The SP2 mode is the Stirling engine operated at maximum power. This is the mode of operation with the highest obtained net electrical power Nel_n = 0.938 kWel. The average water flow rate is Vav = 0.128 dm3/s (459.5 dm3/h), and the device works with an average supply/return temperature difference of ∆Tav = 11.2 K.
The SP3 mode is activated at higher system operating temperatures than the SP1 and SP2 modes. The system was operated at an average water flow rate in the first circuit Vav = 0.200 dm3/s (721.7 dm3/h), for a difference in the supply/return temperatures of ∆Tav = 13.0 K.
For two points describing work with a thermal power above 10.5 kWth (SP4), the following was determined: at state SP4.1, the average water flow rate during five hours of operation was Vav = 0.202 dm3/s (728 dm3/h), for a difference in the supply/return temperature of ∆Tav = 16.6 K on average. At point SP4.2, the average water flow rate was Vav = 0.201 dm3/s (725.3 dm3/h), for a difference in the supply/return temperature of ∆Tav = 20.3 K.
The relationship between the reduction in the net electricity production, together with the increase in the heat load of the cogeneration unit, demonstrated in selected operating states, can also be seen in longer measurements. This results from the reduced power of the Stirling engine caused by the higher temperature of the return water and from the increased energy consumption for its own needs—in this case, for the work of the circulation pump in the first circuit (μCHP—storage tank) and for the operation of the fan supplying air to the combustion chamber. On the basis of the presented work points, one can also see how the flow control system works, which reduced the flow to about 64% (approximately 460 dm3/h) only when working in the SP2 mode.
The results of the conducted experimental analyses of the system with a Stirling engine were confirmed by the literature, which is described in more detail [25,53].
Based on the series of measurements, the system performance characteristics as a function of the return water temperature (cold, TRQ1) were determined and described by the Equation (5). Only the points where the system was enabled were taken into account. The efficiency of the micro-cogeneration device at a point is defined by the following equation:
η = N el _ n + Q ( Q 1 ) E ch
The slope of the approximation function clearly indicates an increased efficiency when the system is operating at a lower temperature range. This is a consequence of the system working as a condensing unit; the lower temperature TRQ1 allows for the recovery of more heat from the exhaust gases, but also provides better cooling for the Stirling engine working in the system, improving its efficiency.
η = { 0.0027 T RQ 1 + 1.0465 , SP 1 , R 2 = 0.883 0.003 T RQ 1 + 1.0351 , SP 2 ,   R 2 = 0.911 0.002 T RQ 1 + 1.0093 , SP 3 ,   SP 4 , R 2 = 0.901

4. Modeling Principles and Assumptions

The energy systems and their parts were investigated through experiments or mathematical modeling. The essence of the mathematical modeling process is mapping the behavior of the real object, although the calculation process often requires a number of simplifications, which can lead to the wrong conclusions. In many cases, running an experiment is impossible for technological reasons or because of the required costs of the laboratory apparatus. Both approaches towards the analysis of the physical phenomena and the operation of utility devices should complement each other as closely as possible. This is represented by the validation of mathematical models based on the results of experiments.
Knowledge of the phenomenological description of the modeled phenomenon allows for forward modeling. Assuming the parameters and structure of the model, which can be very complex, the response for specific input values may be received. However, when it is possible to take measurements from an actual device, one of the possibilities of the mathematical description of its behavior is the use of data-driven modeling. What is more, models of power systems are usually analyzed at the nominal working points of the system, and the use of measurement data makes it possible to include various operating states in the model description; this modeling method was used in this paper. It should be pointed out that data-driven modeling might provide some limitations as the model is influenced by particular dataset; the results are valid for specific case study within the experimental-stand conditions. First, the modeling method is described, and then a comparison of the measurement results and the modeling is presented.
It is necessary to properly assess the efficiency and the operating method of the micro-cogeneration system for various customers. For this purpose, the μCHP unit model was built, which enables the implementation of customer characteristics (as heat and electricity demand profiles).

4.1. General Description of the Model

The μCHP system was modelled in Simulink, which is an integral part of the Matlab computing environment. The main premise of the prepared solution is to present the way the real device operates during a longer working period. The use of the information gathered during long-term measurements of the real micro-cogeneration system allowed for time-domain calculations to be performed. This is necessary, because the presentation of the nature of the device’s operation has a significant impact on the accuracy of the subsequent economic analyses. The modeling of the discussed μCHP system must take into account the fact that, for example, there is a heat buffer included, which not only plays an accumulative role, but also an inertial role. The model is modular, and the exchange of information between the individual modules is continuous. The concept of the model and the data exchange scheme are shown in Figure 10. According to the diagram, the model consists of six modules:
  • M0—a set of input information that is necessary to start the calculations, i.e., heat demand, electricity and ambient temperature demand profiles (consumer characteristics),
  • M1—μCHP management system, the effect of which is to choose the operating mode,
  • M2—a set of data and relationships that directly result from the measurements of the device. It describes the operation of the μCHP system for the given conditions,
  • M3—electricity balances are carried out here. Depending on the configuration of the model, this module may only contain the prosumer’s own consumption and connection to the power grid or other variants of the system’s operation,
  • M4—responsible for the thermal part of the installation. The module calculates the heat accumulator, the heat generation of the μCHP system and the heat used by the consumer,
  • M5—this module archives the behavior of the micro-cogeneration system for the entire time that it is modeled and information from part M3, e.g., the amount of energy used from its own production and the amount of electricity purchased or sold to the grid, which allows for a comprehensive assessment of the prosumer’s efficiency.
The calculations are made in the time domain, therefore the input information to the model must also be presented as a function of time f(τ). This allows for the calculation results to be compared with the results of the laboratory measurements. In the model, the timestep was constant and is equal to τstep = 1 s.

4.2. Operating Modes

In the model of the micro-cogeneration device that was developed, the measurement characteristics presented in Section 3 were used as the main elements describing the operation of the system.
Four main operating modes (OM) termed OM0-OM3 were considered. The OM0 mode is a standby state. In this mode, the system does not generate energy and only uses electricity from the grid for its own needs, i.e., maintaining the power supply of the control system (60 W was adopted). In the OM1 mode, the Stirling engine works at partial load, i.e., it corresponds to the SP1 operating state. In a situation where the value of the water delivery temperature is only slightly lower than the set value, it is possible to work with a lower load (in this case both thermal and electrical) to extend the operating time of the engine itself and produce more electricity.
The OM2 mode is the basic mode where the Stirling engine operates at full load (operating state SP2) and the μCHP system reaches its maximum electrical power. The OM3 mode allows the system to cover the increased heat demand. In addition to the full-load engine, the peak burner (auxiliary boiler) is also started. In this mode, two categories of working conditions were considered. When the Stirling engine cooperates with the peak burner, and the demand does not exceed approximately 10.8 kW, the OM3 mode corresponds to the SP3 operation condition, i.e., the peak burner works with the basic load. When the heat demand increases, the device adapts flexibly to it (as during the K3 measurement series, described in Section 3) which needs to be taken into account in the calculation of the μCHP unit.
A series of measurements were made over a wide range of thermal loads without the Stirling engine running, which allowed for the determination of the peak boiler operational characteristics, which are shown in Figure 11. This was implemented into the OM3 mode in order to cooperate with the engine for higher thermal loads. The role of the heat buffer in this situation is clearly visible, because in the thermal load range from 0 to 10.8 kWth, the system operates in step adjustment and the heat buffer makes it possible to function smoothly with the Stirling engine (and peak boiler) generally operating in an on–off state.
The operation of the auxiliary boiler in the OM3 mode, which generates QAUX heating power in cooperation with the Stirling engine, is reflected by the characteristics shown in Figure 11. The thermal power generated (QAUX) is a function of an “additional” heat demand—QDEM_AUX, i.e., one that exceeds the production capacity of the Stirling engine itself, which is the primary source. The additional demand is determined from the formula:
Q DEM _ AUX = Q DEM Q SE _ MAX
where:
  • QDEM—instantaneous heat demand, kW,
  • QSE_MAX—maximum thermal power of the Stirling engine, kW.
The condition of a maximum thermal power of 26 kWth for the micro-cogeneration device was adopted.
Individual operating modes are characterized by the electrical power and thermal power as well as the water flow rate (according to Section 3). The total efficiency of the device (ηel+th) in a given mode, and thus the use of natural gas chemical energy, is defined as a function of the return water temperature in the first circuit (TRQ1), according to Section 3. Table 2 presents a set of functions describing the individual modes of operation.
The net electricity production in the OM3 mode, in which the electrical power is variable, is described by the function shown in Figure 12. The way the system works in cooperation with the peak source is described in Section 3, and the measurements carried out at three operating points (SP3, SP4.1, SP4.2) allowed for the relationship between the net electrical power and the thermal power of the system to be prepared.

4.3. Management of the μCHP Operation

The micro-cogeneration unit considered was controlled by a PID controller. Based on the temperature signals and set temperatures, it was possible to select the desired power of the device. The management module in the model should not be considered in the category of a control system, because it was not possible to correctly identify the exact way of regulating the μCHP device. The M1 module consists of a set of conditional instructions developed on the basis of long-term observations of the actual system. A comparison of the model’s work with the measurements (described in detail in Section 5) indicates that it satisfactorily manages the operation of the installation model. The presented method of regulating the system allows it to operate in the heat tracking strategy. The generated electricity is, in this case, an additional product.
Figure 13 presents the conditional instructions (thresholds) enabling a given operating mode. The system will activate the mode indicated by a specific condition and will keep it until another condition is met. The calculations always started with the micro-cogeneration device turned off. Two signals were used to control the model’s operation. The calculations provided the possibility of using more information than in the case of the control of the real device. The first signal (u1) is the difference between the value of the desired water supply temperature (which results from the heating curve) and the one that was actually measured. This is an equivalent signal with a control error (e) that would actually be introduced in the PID controller. The second control signal (u2) is the difference between the current heat demand (in kilowatts) and the maximum thermal power of the Stirling engine. This signal indirectly provides the management module with information about the dynamics of the temperature changes. This is additional information for the model control module, which the real controller would be able to identify from the differentiating part. Based on this information, the operating conditions in the individual modes of the device were determined (Figure 13).
Where: u1—signal 1, u2—signal 2, OMi—selected operation mode of the μCHP, i { 0 , 1 , 2 , 3 } , TD_ZAD—desired water delivery temperature (which is a result of the heating curve and depends on the ambient temperature), TDQ1—current water delivery temperature, QDEM—instantaneous heat demand, QSE_MAX—maximum thermal power of the Stirling engine.

4.4. Thermal Part Calculations

The M4 module is responsible for the calculations related to heat generation and dissipation, as well as storage behavior, which is an important element of the system. Thermal energy storage (TES) is a technology that allows for peak loads to be covered and compensated for the fluctuations in heat demand. Heat is stored during periods of overproduction for later use. There are three methods of heat storage: in the form of sensible heat; in the form of latent heat (phase change enthalpy); in the form of thermochemical energy.
A thorough analysis of the heat transfer phenomena in the tank is not a subject of this paper, nevertheless, it is crucial to take it into account in the calculations in order to reflect the nature of the system’s operation. Therefore, elements of the CARNOT library [54] were used to simulate the thermal part of the model. The use of external tools for modeling installation elements or the use of simplified methods is a popular method in the calculation and analysis of cogeneration systems [5,39,47,49].
Calculations of the water heat accumulator were carried out in a one-dimensional model, according to the concept of the division of volumes into nodes, and in each of them heat and mass flow were considered (StorageTank_3 model), described in detail in [54]. This method has been widely adopted in the literature [55,56,57,58]. The parameters that can be set in the tank model (total volume, distribution of the connectors) correspond to the heat buffer, which is part of the laboratory installation (described in Section 2). Heat generation and heat dissipation with the thermal power resulting from the M2 module (μCHP system) and the heat demand profile (M0 module), respectively, were implemented in the heat exchangers [54]. The general scheme of the calculations performed using CARNOT submodels is presented in Figure 14.

4.5. Electrical Part Calculations

Calculations which relate to electricity were solved in the module M3. Appropriate energy balances were made here, depending on the current configuration of the system. In the basic variant, presented in Figure 15, the module contains the prosumer’s own consumption and connection to the power grid.
Figure 15 shows the basic solution, typically used as the μCHP system, for an on-grid application. The electrical power of the μCHP unit (NμCHP) is the net power, i.e., it takes the system’s own needs into account. The prosumer’s own electricity production is used as a priority. When the demand profile (Nd) does not coincide with the current production capacity, the deficits are compensated for by the grid (Npg) or the excess energy produced is fed to the grid (Nsg). The calculation algorithm is shown in Figure 16. In addition to the balance of the sold/purchased power, the DSCkW parameter (in kilowatts) is monitored when performing a given procedure, i.e., covering the electrical demand.

5. Validation of the Model Using Experimental Data

The developed model of the micro-cogeneration system was intended to reflect the operation of the real device. The main application of the model is the possibility of the assessment a prosumer’s system in the heating season or the whole year, which is a valuable representation of the efficiency of the selected technology. This section compares the effects of the modeling with the results of long-term measurements from the laboratory apparatus.

5.1. Evaluation Methods

Due to the use of a model that combines elements of data-driven modeling (μCHP unit, management system based on observations) and elements of analytical calculations using models from the available thermodynamic libraries (thermal part), it was assumed that full compliance was not expected with the measurement of the model at the moment τ0. The goal is the smallest possible deviation in the amount of energy generated (used) in the long-term evaluation. A specific characteristic of heating installations is high inertia (large time constants), so any changes occur relatively slowly.
A simplified scheme of the laboratory installation, where the variables that were validated with the model have been marked, is presented in Figure 17.
Where: T6, T7, T8—temperature sensors in the buffer, TDQ1—water delivery temperature, TRQ1—water return temperature, TDQ2—temperature of the water delivered to the fan heaters, TRQ2—temperature of the water returning from the fan heaters, Q(Q1)—thermal power of the μCHP—heat generation, Q(Q2)—thermal power of the fan heaters—heat demand.
During the validation, as a set of input information to the model, the heat demand profile and the ambient temperature profile, which were obtained during the measurements, were introduced. The record of the operation of the real μCHP system was then compared to the operation of the model. During validation, the relative error δ of the following parameters was calculated: the amount of heat generated Eth (δth), the amount of electricity generated Eel (δel), the amount of natural gas Egas (δgas) used, the operating time of the Stirling engine τSE (δSE). It is necessary to distinguish between the values of the electricity generated and the operating time of the engine due to the two possible modes of its operation (of different powers). The checked parameters are described by Equations (8)–(10). The relative error is defined by Equation (11).
E th = 0 τ val Q d τ
E e l = 0 τ v a l N μ C H P d τ
E g a s = 0 τ v a l E c h d τ
δ = | x x 0 | | x 0 | · 100 %
where: x—modeled variable, x0—measured variable.
The verification calculations did not include the M3 module with the electricity balance, because all the energy (net) generated from the real installation was fed into the grid.
The checking of the compliance of the model with the operation of the actual installation was carried out for a variety of cases, which differed in heat demand profile and water temperature operating range.

5.2. Results of Validation

Four representative cases (SPR1-SPR4) were considered, and in each case, the system’s operating time was equal to τval = 24 h, which was monitored and modeled. Due to the short form of this publication, the results of the calculations for cases SPR1 and SPR2 are presented graphically. The results of the validation calculations in the form of the analyzed parameters values and error percentage are presented in Table 3 and Table 4, respectively.
Figure 18, Figure 19, Figure 20 and Figure 21 present the temperature waveforms at the characteristic points (marked in Figure 17) and the thermal powers (generation and demand) were recorded during the measurements and modeled. The SPR1 variant is characterized by a heat demand profile in the range of 0–8 kWth and a TDQ1 water delivery temperature in the range of 50–60 °C (this depends on the ambient temperature). In the case of the SPR2 variant, the heat demand is up to 10 kWth, for a water delivery temperature of approximately 60 °C. The analyzed SPR3 case is characterized by an almost constant heat demand profile at the level of about 6 kWth at a water supply temperature of 45 °C, which allowed the mostly “Stirling engine-only” (without the auxiliary boiler) operation modes to be analyzed. The final option considered, SPR4, allowed the model’s behavior to be observed when the heat demand is increased, even up to 16 kWth and a TDQ1 temperature above 70 °C.
The analysis of the presented data indicates that the operation of the proposed model satisfactorily reflects the operation of the micro-cogeneration system. The modeled μCHP device maintained the desired water delivery temperature using the operating modes characterizing the real unit. The calculations that were performed using the prepared model were evaluated in the form of a comparison (between the model and the experiment) of the amount of energy produced (or used) and the determination of the relative error. Table 3 contains the results of the validation for daily runs, and Table 4 presents the relative error percentage for the individual types of energy and the operating time of the Stirling engine. The “mod” index refers to the values obtained from the modeling, while the “exp” index refers to the measured values. The designations in the tables were used in accordance with the Equations (9)–(11).
In the case of heat generation, the model worked best for the SPR2 variant—the relative error value δth of which was 0.31%. This calculation variant had an error equal to δel = 2.50% related to electricity generation. The smallest relative error (δgas = 0.26%) in determining the use of the chemical energy of natural gas was achieved in the SPR3 variant, which at the same time was the least favorable in terms of assessing the Stirling engine’s operating time (δSE = 8.58%). The operating time of the Stirling engine was modeled with good accuracy in the SPR2 calculations (δSE = 0.14%) and in the SPR1 calculations (δSE = 1.32%), which were characterized by the largest error in heat generation (δth = 4.50%). The range of discrepancies is influenced by the use of simplified characteristics, which was obtained from the system measurements (e.g., application of linear functions), analytical elements (a one-dimensional model of the heat storage from the CARNOT thermodynamic libraries) and their impact on the operating temperature range, on which the current efficiency of the micro-cogeneration unit directly depends. Nevertheless, the presented level of discrepancy should not have a significant impact on the assessment of the system’s effectiveness over a year or heating season.
The calculations of the micro-cogeneration unit operation were also carried out for a longer period (τval = 10 days) using the K2 measurement series (described in detail in Section 3) for additional verification (SPRK2 variant). The results of the calculations and the relative error percentage are also presented in Table 3 and Table 4. The analysis of the results clearly indicates that the increase in the modeled operating time of the μCHP device did not cause the increase in the relative error in relation to the measurements of the actual installation. The proposed computational model can be used for system analysis and assessment of the efficiency of the micro-cogeneration system.

6. Conclusions

The main purpose of the work presented in the paper was to experimentally determine the operational characteristics and efficiency of a micro-cogeneration system based on a free piston Stirling engine, as well as to accurately map its characteristics in the form of a computational model.
The following research tasks were carried out:
  • a laboratory setup was developed that could take measurements of the micro-cogeneration unit during long-term operation with a variable thermal load. The achievements also include the implementation of operating schedules enabling comprehensive measurements to be carried out over the full power range of the device and revealing all the operating modes of the μCHP module. The control and measurement system enabled the simulation of variable ambient conditions and forced operation with the use of all the operational modes without interfering with the μCHP’s internal control system. The measurements were carried out, which enabled the operational characteristics and thermodynamic efficiency of the micro-cogeneration unit to be determined,
  • a model of the analyzed micro-cogeneration system was built in the Matlab and Simulink environment. The simulation model was based on the device’s characteristics that were obtained from the measurements. It enabled time-domain calculations (simulations) that took into account the different operating modes of the device. It allows for the operation of the μCHP unit to be simulated for various types of consumers because of the possibility of implementing the given profile of electricity and heat demand. The developed model, due to its modular structure, is a tool that can be used for the analysis of distributed energy systems. It enables the implementation of various devices and control methods and has provided a good basis for modeling other energy systems. The calculations that were made with the use of the model were compared with the measurement results, which revealed good compliance when assessing 24-h operation of the μCHP unit or longer.
The completed research tasks can be summarized as follows:
  • four basic operating modes of the micro-cogeneration system were determined. The net electrical power of the Stirling engine operating within the system varied in the range of 0.65–0.94 kW. The system was tested in the thermal power range of 4.6–16.7 kW. A maximum efficiency of electricity generation of ηel_av = 13.2% was achieved for the SP2 mode with full engine load (without the peak burner). A highest overall efficiency of ηel+q_av = 95.7% was achieved for the SP1 mode with partial engine load (without the peak burner), which resulted from the unit operating at the lowest water temperatures and recovering more heat from the exhaust gases,
  • the results showed that the developed model sufficiently reflected the actual operation of the device. The relative errors of the heat and electricity generation, as well as the natural gas use and the operating time of the engine for longer operating periods of the μCHP unit, were analyzed. For a modeled period of τval = 24 h, the error in the heat generation fluctuated in the range of δth = 0.31–4.50%, the error in the electricity generation was δel = 2.48–4.70%, the error in the natural gas consumption was δgas = 0.26–4.59%, and the engine’s runtime error was δSE = 0.14–8.58%.
  • the modelling process is applicable to other energy systems.
The next step towards recognition of the full potential of the micro-cogeneration units is a comprehensive system analysis, utilizing the proposed model. For instance, gas-fueled micro-cogenerators, as a stable prime mover, could be integrated with an electrical energy storage or renewable energy systems (e.g., photovoltaic system) to increase the prosumer’s self-sufficiency and the reliability of the distributed generation technologies. These are worthwhile topics for further exploration.

Author Contributions

Conceptualization, W.U.; Formal analysis, W.U.; Funding acquisition, W.U.; Investigation, W.U., J.K. and L.R.; Methodology, W.U.; Resources, J.K. and L.R.; Writing—original draft, W.U. All authors have read and agreed to the published version of the manuscript.

Funding

The publication was supported by the SUT Rector’s grant. Silesian University of Technology, project no. 08/050/RGJ20/0208. WU gratefully acknowledge the support of the National Science Centre (Poland, Kraków) through the Etiuda scholarship (project no. 2018/28/T/ST8/00160).

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

cenergy demand profile
CHPcombined heat and power
Eenergy, kWh, GJ
FELfollowing the electrical load strategy
FPSEfree-piston Stirling engine
FTLfollowing the thermal load strategy
Kheating curve
LHVlower heating value, MJ/m3n
Mmodule of the μCHP model
Nelectrical power, kW
OMoperating mode of the model
Qthermal power, kW
SPoperating mode of the device
SPRvalidation variant
T, ttemperature, K, °C
ucontrol signal
Vflow, dm3/s, dm3/h
δrelative error, %
ηefficiency
μCHPmicro-cogeneration unit
τtime, seconds, hours, days

Indices

ambambient
AUXrelated to the auxiliary burner
avaverage
bgross
chrelated to the chemical energy of the fuel
drelated to the current energy demand
D_ZADset water delivery temperature
DQwater delivery temperature
elrelated to the electrical energy
expmeasured value
gasrelated to natural gas
measrelated to the measurements
modmodeled value
nnet
nomnominal
Qrelated to the heat meter
q, ththermal
RQwater return temperature
SErelated to the Stirling engine
stepcalculation step
totaltotal, overall
valrelated to the validation of the model

References

  1. European Parliament and Council. Directive 2012/27/EU of the European Parliament and of the Council of 25 October 2012 on Energy Efficiency, Amending Directives 2009/125/EC and 2010/30/EU and Repealing Directives 2004/8/EC and 2006/32/EC; European Parliament and Council: Strasbourg, France, 2012. [Google Scholar]
  2. Murugan, S.; Horak, B. A review of micro combined heat and power systems for residential applications. Renew. Sustain. Energy Rev. 2016, 64, 144–162. [Google Scholar] [CrossRef]
  3. Peris, B.; Navarro-Esbri, J.; Moles, F.; Marti, J.P.; Mota-Babiloni, A. Experimental characterization of an Organic Rankine Cycle (ORC) for micro-scale CHP applications. Appl. Eng. 2015, 79, 1–8. [Google Scholar] [CrossRef]
  4. Roselli, C.; Sasso, M.; Sibilio, S.; Tzscheutschler, P. Experimental analysis of microcogenerators based different prime movers. Energy Build. 2011, 43, 796–804. [Google Scholar] [CrossRef]
  5. De Paepe, M.; D’Herdt, P.; Mertens, D. Micro-CHP systems for residential applications. Energy Convers Manag. 2006, 47, 3435–3446. [Google Scholar] [CrossRef]
  6. Maghanki, M.M.; Ghobadian, B.; Najafi, G.; Galogah, R.J. Micro combined heat and power (MCHP) technologies and applications. Renew. Sustain. Energy Rev. 2013, 28, 510–524. [Google Scholar] [CrossRef]
  7. Kupecki, J.; Jewulski, J.; Motylinski, K. Parametric evaluation of a micro-CHP unit with solid oxide fuel cells integrated with oxygen transport membranes. Int. J. Hydrogen Energy 2015, 40, 11633–11640. [Google Scholar] [CrossRef] [Green Version]
  8. Zare, S.H.; Tavakolpour-Saleh, A.R. Free piston Stirling engines: A review. Int. J. Energy Res. 2019, 43, 1–32. [Google Scholar] [CrossRef]
  9. Tavakolpour-Saleh, A.R.; Zare, S.H.; Bahreman, H. A novel active free piston Stirling engine: Modeling, development and experiment. Appl. Energy 2017, 199, 400–415. [Google Scholar] [CrossRef]
  10. Valenti, G.; Silva, P.; Fergnani, N.; Campanari, S.; Ravida, A.; Di Marcoberardino, G.; Macchi, E. Experimental and numerical study of a micro-cogeneration Stirling unit under diverse conditions of the working fluid. Appl. Energy 2015, 160, 920–929. [Google Scholar] [CrossRef] [Green Version]
  11. Ahmadi, M.H.; Ahmadi, M.-A.; Pourfayaz, F. Thermal models for analysis of performance of Stirling engine: A review. Renew. Sustain. Energy Rev. 2017, 68, 168–184. [Google Scholar] [CrossRef]
  12. Paul, C.J.; Engeda, A. Modeling a complete Stirling engine. Energy 2015, 80, 85–97. [Google Scholar] [CrossRef] [Green Version]
  13. Formosa, F. Coupled thermodynamic-dynamic semi-analytical model of free piston Stirling engines. Energy Convers. Manag. 2011, 52, 2098–2109. [Google Scholar] [CrossRef] [Green Version]
  14. Riofrio, J.A.; Al-Dakkan, K.; Hofacker, M.E.; Barth, E.J. Control-based design of free piston Stirling engines. In Proceedings of the American Control Conference, Seattle, WA, USA, 11–13 June 2008. [Google Scholar]
  15. Zare, S.H.; Tavakolpour-Saleh, A.R. Frequency-based design of a free piston Stirling engine using genetic algorithm. Energy 2016, 109, 117–124. [Google Scholar] [CrossRef]
  16. Zhu, S.; Yu, G.; Jongmin, O.; Xu, T.; Wu, Z.; Dai, W.; Luo, E. Modeling and experimental investigation of a free-piston Stirling engine-based micro-combined heat and power system. Appl. Energy 2018, 226, 522–533. [Google Scholar] [CrossRef]
  17. Qiu, S.; Gao, Y.; Rinker, G.; Yanaga, K. Development of an advanced free-piston Stirling engine for micro combined heating and power application. Appl. Energy 2019, 235, 987–1000. [Google Scholar] [CrossRef]
  18. Uchman, W.; Remiorz, L.; Grzywnowicz, K.; Kotowicz, J. Parametric analysis of a beta Stirling engine—A prime mover for distributed generation. Appl. Eng. 2018, 145, 693–704. [Google Scholar] [CrossRef]
  19. Bartela, Ł.; Kotowicz, J.; Dubiel-Jurgaś, K. Investment risk for biomass integrated gasification combined heat and power unit with an internal combustion engine and Stirling engine. Energy 2018, 150, 601–616. [Google Scholar] [CrossRef]
  20. Damirchi, H.; Najafi, G.; Alizadehnia, S.; Mamat, R.; Che Sidik, N.A.; Azmi, W.H.; Noor, M.M. Micro combined heat and power to provide heat and electrical power using biomass and gamma-type Stirling engine. Appl. Eng. 2016, 103, 1460–1469. [Google Scholar] [CrossRef] [Green Version]
  21. Habibollahzade, A.; Gholamian, E.; Houshfar, E.; Behzadi, A. Multi-objective optimization of biomass-based solid oxide fuel cell integrated with Stirling engine and electrolyzer. Energy Convers. Manag. 2018, 171, 1116–1133. [Google Scholar] [CrossRef]
  22. Skorek-Osikowska, A.; Kotowicz, J.; Uchman, W. Thermodynamic assessment of the operation of a self-sufficient, biomass based district heating system integrated with a Stirling engine and biomass gasification. Energy 2017, 141, 1764–1778. [Google Scholar] [CrossRef]
  23. Bouvenot, J.-B.; Andlauer, B.; Stabat, P.; Marchio, D.; Flament, B.; Latour, B.; Siroux, M. Gas Stirling engine μCHP boiler experimental data driven model for building energy simulation. Energy Build. 2014, 84, 117–131. [Google Scholar] [CrossRef]
  24. Conroy, G.; Duffy, A.; Ayompe, L.M. Economic, energy and GHG emissions performance evaluation of a WhisperGen Mk IV Stirling engine μ-CHP unit in a domestic dwelling. Energy Convers. Manag. 2014, 81, 465–474. [Google Scholar] [CrossRef]
  25. Lipp, J. Field test with Stirling engine micro-combined heat and power units in residential buildings. Proc. Inst. Mech. Eng. Part A J. Power Energy 2012, 227, 43–52. [Google Scholar] [CrossRef]
  26. Balcombe, P.; Rigby, D.; Azapagic, A. Energy self-sufficiency, grid demand variability and consumer costs: Integrating solar PV, Stirling engine CHP and battery storage. Appl. Energy 2015, 155, 393–408. [Google Scholar] [CrossRef]
  27. Barbieri, E.S.; Melino, F.; Morini, M. Influence of the thermal energy storage on the profitability of micro-CHP systems for residential building applications. Appl. Energy 2012, 97, 714–722. [Google Scholar] [CrossRef]
  28. Gonzalez-Pino, J.; Iribarren-Perez, E.; Campos-Celador, A.; Las-Heras-Casas, J.; Sala, J.M. Influence of the regulation framework on the feasibility of a Stirling engine-based residential micro-CHP installation. Energy 2015, 84, 575–588. [Google Scholar] [CrossRef]
  29. Rosato, A.; Sibilio, S.; Ciampi, G. Energy, environmental and economic dynamic performance assessment of different micro-cogeneration systems in a residential application. Appl. Eng. 2013, 59, 599–617. [Google Scholar] [CrossRef]
  30. Ulloa, C.; Miguez, J.L.; Porteiro, J.; Eguia, P.; Cacabelos, A. Development of a transient model of a Stirling-based CHP system. Energies 2013, 6, 3115–3133. [Google Scholar] [CrossRef] [Green Version]
  31. Ulloa, C.; Porteiro, J.; Eguia, P.; Pousada-Carballo, J.M. Application model for a Stirling engine micro-cogeneration system in caravans in different european locations. Energies 2013, 6, 717–732. [Google Scholar] [CrossRef] [Green Version]
  32. Conroy, G.; Duffy, A.; Ayompe, L.M. Validated dynamic energy model for a Stirling engine μ-CHP unit using field trial data from a domestic dwelling. Energy Build. 2013, 62, 18–26. [Google Scholar] [CrossRef]
  33. Beausoleil-Morrison, I. An Experimental and Simulation-based Investigation of the Performance of Small-Scale Fuel Cell and Combustion-based Cogeneration Devices Serving Residential Buildings. Annex 42 of the International Energy Agency Energy Conservation in Buildings and Community Systems Programme; Government of Canada: Ottawa, ON, Canada, 2008.
  34. Lombardi, K.; Ugursal, V.I.; Beausoleil-Morrison, I. Proposed improvements to a model for characterizing the electrical and thermal energy performance of Stirling engine micro-cogeneration devices based upon experimental observations. Appl. Energy 2010, 87, 3271–3282. [Google Scholar] [CrossRef]
  35. Alanne, K.; Soderholm, N.; Siren, K.; Beausoleil-Morrison, I. Techno-economic assessment and optimization of Stirling engine micro-cogeneration systems in residential buildings. Energy Convers. Manag. 2010, 51, 2635–2646. [Google Scholar] [CrossRef]
  36. Rosato, A.; Sibilio, S. Calibration and validation of a model for simulating thermal and electric performance of an internal combustion engine-based micro-cogeneration device. Appl. Eng. 2012, 45–46, 79–98. [Google Scholar] [CrossRef]
  37. Magri, G.; Di Perna, C.; Serenelli, G. Analysis of electric and thermal seasonal performances of a residential microCHP unit. Appl. Eng. 2012, 36, 193–201. [Google Scholar] [CrossRef]
  38. Angrisani, G.; Canelli, M.; Roselli, C.; Sasso, M. Microcogeneration in buildings with low energy demand in load sharing application. Energy Convers. Manag. 2015, 100, 78–89. [Google Scholar] [CrossRef]
  39. Angrisani, G.; Canelli, M.; Roselli, C.; Sasso, M. Integration between electric vehicle charging and micro-cogeneration system. Energy Convers. Manag. 2015, 98, 115–126. [Google Scholar] [CrossRef]
  40. Cai, B.; Li, H.; Hu, Y.; Zhang, G. Operation strategy and sustainability analysis of CHP system with heat recovery. Energy Build. 2017, 141, 284–294. [Google Scholar] [CrossRef]
  41. Liu, M.; Shi, Y.; Fang, F. A new operation strategy for CCHP systems with hybrid chillers. Appl. Energy 2012, 96, 164–173. [Google Scholar] [CrossRef]
  42. Ummenhofer, C.D.; Heyer, G.; Roediger, T.; Olsen, J.; Page, J. Improved system control logic for an MCHP system incorporating electric storage. Appl. Energy 2017, 203, 737–751. [Google Scholar] [CrossRef]
  43. Houwing, M.; Negenborn, R.R.; De Schutter, B. Demand response with micro-CHP systems. Proc. IEEE 2011, 90, 200–213. [Google Scholar] [CrossRef] [Green Version]
  44. Shaneb, O.A.; Taylor, P.C.; Coates, G. Real time operation of μCHP systems using fuzzy logic. Energy Build. 2012, 55, 141–150. [Google Scholar] [CrossRef]
  45. Nayak, S.K.; Gaonkar, D.N.; Shivarudraswamy, R. Fuzzy logic controlled microturbine generation system for distributed generation. Enrgy Procedia 2012, 14, 1213–1219. [Google Scholar] [CrossRef] [Green Version]
  46. Putrayudha, S.A.; Kang, E.C.; Evgueniy, E.; Libing, Y.; Lee, E.J. A study of photovoltaic/thermal (PVT)-ground source heat pump hybrid system by using fuzzy logic control. Appl. Eng. 2015, 89, 578–586. [Google Scholar] [CrossRef]
  47. Balcombe, P. Energy from Microgeneration: Sustainability and Perceptions in the UK. Ph.D. Thesis, University of Manchester, Manchester, UK, 2014. [Google Scholar]
  48. Caliano, M.; Bianco, N.; Graditi, G.; Mongibello, L. Economic optimization of a residential micro-CHP system considering different operation strategies. Appl. Eng. 2016, 101, 592–600. [Google Scholar] [CrossRef]
  49. Skorek-Osikowska, A.; Remiorz, L.; Bartela, Ł.; Kotowicz, J. Potential for the use of micro-cogeneration prosumer systems based on the Stirling engine with an example in the Polish market. Energy 2017, 133, 46–61. [Google Scholar] [CrossRef]
  50. Liu, M.; Shi, Y.; Fang, F. Optimal power flow and PGU capacity of CCHP systems using a matrix modeling approach. Appl. Energy 2013, 102, 794–802. [Google Scholar] [CrossRef]
  51. Dorer, V.; Weber, A. Energy and CO2 emissions performance assessment of residential micro-cogeneration systems with dynamic whole-building simulation programs. Energy Convers. Manag. 2009, 50, 648–657. [Google Scholar] [CrossRef]
  52. Microgen Engines. Available online: www.microgen-engine.com (accessed on 16 March 2017).
  53. Remiorz, L.; Kotowicz, J.; Uchman, W. Comparative assessment of the effectiveness of a free-piston Stirling engine-based micro-cogeneration unit and a heat pump. Energy 2018, 148, 134–147. [Google Scholar] [CrossRef]
  54. CARNOT Toolbox Ver. 6.1, 05/2017 for Matlab/Simulink R2013b Software; Solar-Institut Juelich, University of Applied Sciences FH Aachen: Aachen, Germany, 2017.
  55. Cadafalch, J.; Carbonell, D.; Consul, R.; Ruiz, R. Modelling of storage tanks with immersed heat exchangers. Sol. Energy 2015, 112, 154–162. [Google Scholar] [CrossRef] [Green Version]
  56. Nash, A.L.; Badithela, A.; Jain, N. Dynamic modeling of a sensible thermal energy storage tank with an immersed coil heat exchanger under three operation modes. Appl. Energy 2017, 195, 877–889. [Google Scholar] [CrossRef]
  57. Patankar, S.V. Numerical Heat Transfer and Fluid Flow; Hemisphere Publishing Company: Washington, DC, USA, 1980. [Google Scholar]
  58. Rahman, A.; Smith, A.D.; Fumo, N. Performance modeling and parametric study of a stratified water thermal storage tank. Appl. Eng. 2016, 100, 668–679. [Google Scholar] [CrossRef]
Figure 1. Scheme of the research apparatus of the micro-cogeneration unit. Reprinted from Energy, 148, Remiorz L., Kotowicz J., Uchman W., Comparative assessment of the effectiveness of a free-piston Stirling engine-based micro-cogeneration unit and a heat pump, 134–147, Copyright (2018), with permission from Elsevier.
Figure 1. Scheme of the research apparatus of the micro-cogeneration unit. Reprinted from Energy, 148, Remiorz L., Kotowicz J., Uchman W., Comparative assessment of the effectiveness of a free-piston Stirling engine-based micro-cogeneration unit and a heat pump, 134–147, Copyright (2018), with permission from Elsevier.
Energies 13 02759 g001
Figure 2. Recorded levels of the ambient temperature T5 (black line), the water delivery temperature TDQ1 (red line), and the return temperature TRQ1 (blue line) for the K1 series.
Figure 2. Recorded levels of the ambient temperature T5 (black line), the water delivery temperature TDQ1 (red line), and the return temperature TRQ1 (blue line) for the K1 series.
Energies 13 02759 g002
Figure 3. Thermal power of the micro-cogeneration (μCHP) unit Q(Q1) (black line) and the heat demand Q(Q2) (red line) for the K1 series.
Figure 3. Thermal power of the micro-cogeneration (μCHP) unit Q(Q1) (black line) and the heat demand Q(Q2) (red line) for the K1 series.
Energies 13 02759 g003
Figure 4. Thermal power Q(Q1) (black line) and the net electrical power Nel_n (green line) of the μCHP unit; chemical energy of the fuel Ech (yellow line) for the K1 series.
Figure 4. Thermal power Q(Q1) (black line) and the net electrical power Nel_n (green line) of the μCHP unit; chemical energy of the fuel Ech (yellow line) for the K1 series.
Energies 13 02759 g004
Figure 5. Recorded levels of the ambient temperature T5 (black line), the water delivery temperature TDQ1 (red line), and the return temperature TRQ1 (blue line) for the K3 series.
Figure 5. Recorded levels of the ambient temperature T5 (black line), the water delivery temperature TDQ1 (red line), and the return temperature TRQ1 (blue line) for the K3 series.
Energies 13 02759 g005
Figure 6. Thermal power of the μCHP unit Q(Q1) and the heat demand Q(Q2) for the K3 series.
Figure 6. Thermal power of the μCHP unit Q(Q1) and the heat demand Q(Q2) for the K3 series.
Energies 13 02759 g006
Figure 7. Thermal power Q(Q1) (black line) and net electrical power Nel_n (green line) of the μCHP unit; chemical energy of the fuel Ech (yellow line) for the K3 series.
Figure 7. Thermal power Q(Q1) (black line) and net electrical power Nel_n (green line) of the μCHP unit; chemical energy of the fuel Ech (yellow line) for the K3 series.
Energies 13 02759 g007
Figure 8. The investigated heating curves K1, K2 and K3 (TDQ1 as a function of T5 = Tamb).
Figure 8. The investigated heating curves K1, K2 and K3 (TDQ1 as a function of T5 = Tamb).
Energies 13 02759 g008
Figure 9. Characteristics of the SP2 operating conditions.
Figure 9. Characteristics of the SP2 operating conditions.
Energies 13 02759 g009
Figure 10. Scheme of the continuous information transfer in the model.
Figure 10. Scheme of the continuous information transfer in the model.
Energies 13 02759 g010
Figure 11. Model-implemented auxiliary boiler characteristic, based on the experiment.
Figure 11. Model-implemented auxiliary boiler characteristic, based on the experiment.
Energies 13 02759 g011
Figure 12. Electrical power in the OM3 mode, Nel_n = f(Q(Q1)).
Figure 12. Electrical power in the OM3 mode, Nel_n = f(Q(Q1)).
Energies 13 02759 g012
Figure 13. Module M1—management of the modeled μCHP operation.
Figure 13. Module M1—management of the modeled μCHP operation.
Energies 13 02759 g013
Figure 14. Scheme of simplified calculations in M4 module.
Figure 14. Scheme of simplified calculations in M4 module.
Energies 13 02759 g014
Figure 15. Basic configuration of the FPSE-based μCHP for a prosumer.
Figure 15. Basic configuration of the FPSE-based μCHP for a prosumer.
Energies 13 02759 g015
Figure 16. Algorithm of the calculations in the M3 module.
Figure 16. Algorithm of the calculations in the M3 module.
Energies 13 02759 g016
Figure 17. Simplified installation scheme with the measurement points that were used for validation.
Figure 17. Simplified installation scheme with the measurement points that were used for validation.
Energies 13 02759 g017
Figure 18. Top: recorded levels of the temperature at the measurement points; bottom: thermal power of the μCHP unit (Q(Q1)) and the heat demand (Q(Q2)), for variant SPR1—measurements.
Figure 18. Top: recorded levels of the temperature at the measurement points; bottom: thermal power of the μCHP unit (Q(Q1)) and the heat demand (Q(Q2)), for variant SPR1—measurements.
Energies 13 02759 g018
Figure 19. Top: recorded levels of the temperature at the measurement points; bottom: thermal power of the μCHP unit (Q(Q1)) and the heat demand (Q(Q2)), for variant SPR1—modeling.
Figure 19. Top: recorded levels of the temperature at the measurement points; bottom: thermal power of the μCHP unit (Q(Q1)) and the heat demand (Q(Q2)), for variant SPR1—modeling.
Energies 13 02759 g019
Figure 20. Top: recorded levels of the temperature at the measurement points; bottom: thermal power of the μCHP unit (Q(Q1)) and the heat demand (Q(Q2)), for variant SPR2—measurements.
Figure 20. Top: recorded levels of the temperature at the measurement points; bottom: thermal power of the μCHP unit (Q(Q1)) and the heat demand (Q(Q2)), for variant SPR2—measurements.
Energies 13 02759 g020
Figure 21. Top: recorded levels of the temperature at the measurement points; bottom: thermal power of the μCHP unit (Q(Q1)) and the heat demand (Q(Q2)), for variant SPR2—modeling.
Figure 21. Top: recorded levels of the temperature at the measurement points; bottom: thermal power of the μCHP unit (Q(Q1)) and the heat demand (Q(Q2)), for variant SPR2—modeling.
Energies 13 02759 g021
Table 1. Measured operating conditions of the μCHP unit.
Table 1. Measured operating conditions of the μCHP unit.
Operating ConditionsDescriptionNel_n, kWQ(Q1), kWEch, kWηel_av, -ηq_av, -ηel+q_av, -
SP1partial load of the engine0.6484.6005.4830.1180.8390.957
SP2full load of the engine0.9385.8617.1170.1320.8230.955
SP3full load of the engine + minimum load of the auxiliary boiler0.86210.78912.7750.0670.8450.912
SP4.1full load of the engine + partial load of the auxiliary boiler (modulated)0.78213.74416.1580.0480.8510.899
SP4.2full load of the engine + partial load of the auxiliary boiler (modulated)0.72816.67719.6000.0370.8510.888
Table 2. Parameters of the μCHP unit in the various operating modes.
Table 2. Parameters of the μCHP unit in the various operating modes.
Operating ModeNel_n, kWelQ, kWthV(Q1), dm3/hηel+th, -
OM10.6484.600709.5 η el + th = 0.0027 T RQ 1 + 1.0465 , R2 = 0.883
OM20.9385.861459.5 η el + th = 0.003 T RQ 1 + 1.0351 , R2 = 0.911
OM3 Q DEM 10.789 0.86210.789720.0 η el + th = 0.002 T RQ 1 + 1.0093 , R2 = 0.901
Q DEM > 10.789 N = 0.0228 Q + 1.1034 , R2 = 0.988QSE_MAX + QAUX720.0
Table 3. Validation results for the 24-hour cycle and 10-day cycle operation of the μCHP.
Table 3. Validation results for the 24-hour cycle and 10-day cycle operation of the μCHP.
VariantEth(exp)Eth(mod)Egas(exp)Egas(mod)Eel(exp)Eel(mod)τSE(exp)τSE(mod)
kWhMJkWhMJkWhMJkWhMJkWhkWhhh
SPR1146.6527.8140.0504.0178.0640.8173.8625.719.618.821.1620.88
SPR2192.9694.4192.3692.3233.5840.6231.3832.719.619.121.8321.80
SPR3124.1446.8122.3440.3151.4545.0151.0543.619.318.922.520.57
SPR4278.31001.9270.2972.7339.91223.6324.31167.517.718.522.9722.08
SPRK21543.05554.81479.05324.41861.06699.61790.06444.0184.3180.5215.1201.9
Table 4. Relative error of the analyzed parameters for the 24-hour cycle and 10-day cycle operation of the μCHP.
Table 4. Relative error of the analyzed parameters for the 24-hour cycle and 10-day cycle operation of the μCHP.
Variant δth, %δgas, %δel, %δSE, %
SPR14.502.364.031.32
SPR20.310.942.500.14
SPR31.450.262.488.58
SPR42.914.594.703.87
SPRK24.153.822.066.14

Share and Cite

MDPI and ACS Style

Uchman, W.; Kotowicz, J.; Remiorz, L. An Experimental Data-Driven Model of a Micro-Cogeneration Installation for Time-Domain Simulation and System Analysis. Energies 2020, 13, 2759. https://doi.org/10.3390/en13112759

AMA Style

Uchman W, Kotowicz J, Remiorz L. An Experimental Data-Driven Model of a Micro-Cogeneration Installation for Time-Domain Simulation and System Analysis. Energies. 2020; 13(11):2759. https://doi.org/10.3390/en13112759

Chicago/Turabian Style

Uchman, Wojciech, Janusz Kotowicz, and Leszek Remiorz. 2020. "An Experimental Data-Driven Model of a Micro-Cogeneration Installation for Time-Domain Simulation and System Analysis" Energies 13, no. 11: 2759. https://doi.org/10.3390/en13112759

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop