A Study of Low-Potential Heat Utilization Methods for Oxy-Fuel Combustion Power Cycles

1
Department of Innovative Technologies of High-Tech Industries, National Research University “Moscow Power Engineering Institute”, 111250 Moscow, Russia
2
Department of Thermal Power Plants, National Research University “Moscow Power Engineering Institute”, 111250 Moscow, Russia
*
Author to whom correspondence should be addressed.
Energies 2021, 14(12), 3364; https://doi.org/10.3390/en14123364
Submission received: 27 April 2021 / Revised: 31 May 2021 / Accepted: 4 June 2021 / Published: 8 June 2021
(This article belongs to the Special Issue CFD Simulation in Energy Efficiency and Building Energy Saving)

Abstract

:
The world community is worried about the effects of global warming. A few agreements on the reduction of CO2 emissions have been signed recently. A large part of these emissions is produced by the power production industry. Soon, the requirements for thermal power plant ecology and efficiency performance may become significantly higher. Thus, the contemporary problem is the development of highly efficient power production facilities with low toxic and greenhouse gas emission. An efficient way to reduce CO2 emissions into the atmosphere, which implies maintaining economic growth, is the creation of closed thermodynamic cycles with oxy-fuel combustion. The Allam cycle is one of the most promising among oxy-fuel power plants. A 50 MW pilot Allam cycle plant was built in Texas. The design for a commercial system with an electrical output of 300 MW is under development. This work is devoted to the improvement of the efficiency and environmental safety of oxy-fuel combustion power cycles via the utilization of compressed working fluid heat. The results of computer simulation obtained using AspenONE software demonstrated that an additional circuit in the multi-flow regenerator might increase net efficiency by 3.5%. Besides this, the incorporation of a supercritical carbon dioxide (S–CO2) Brayton cycle with recompression increased the efficiency by 0.2%. Therefore, the maximum net efficiency of the prospective power unit was 51.4%.

1. Introduction

Available power and the growth rate of electricity production are important factors in economic development. In recent decades, renewable power sources have grown rapidly, but the majority of heat and electricity are still produced by the combustion of organic fuels. This tendency will probably remain, for technical and financial reasons [1,2].
The environmental safety of thermal power plants operating with organic fuel may be remarkably improved by a transition to oxy-fuel combustion power cycles, with carbon dioxide as a working fluid [3,4,5]. The key elements of the prospective power generation technology are an oxy-fuel combustion chamber and carbon dioxide capture and storage (CCS) systems. Reviews of the different oxy-fuel combustion power cycles have shown that the most effective is the Allam cycle [6,7,8]. Its net efficiency could be above 50% [9,10].
The Allam cycle is a supercritical, CO2 Brayton cycle with oxy-fuel combustion and recuperation. NET Power and 8 Rivers Capital, together with Toshiba, CB&I, and Exelon, developed a 50 MW Allam cycle plant in Texas. The design for a commercial system with an electrical output of 300 MW is under development. The main challenges in scaling up the system are the development of a high-pressure, oxy-fuel combustor operating in a wide pressure range [11], which is a compact, multi-stream heat exchanger, the design of which provides high thermal cycle efficiency and moderate expenses for heat resistant alloys [12]. Partial load regimes also should be considered before the implementation of a high-power, oxy-fuel power plant [13].
The preferable fuel allowing for achieve maximum efficiency for the Allam cycle is natural gas. Nevertheless, world coal resources are three times larger than natural gas ones [14,15] and therefore, the development of coal-fired power generation units with near-zero emissions is also a promising direction. A possible means for the transition to solid fuels in the oxy-fuel combustion cycle is gasification. According to the modeling results presented in [16], an implementation of gasification technologies remarkably reduced power plant thermal efficiency.
In particular, the Allam cycle with coal gasification and use of syngas sensible heat in an additional steam turbine cycle compared with an integrated gasification combined cycle (IGCC) in the paper [17]. The Allam cycle net efficiency was 39.6%, which was a little lower than the 40% net efficiency value of the IGCC without CO2 capturing. However, nearly complete carbon capture is the Allam cycle’s advantage against the IGCC.
Papers [18,19] disclose the efficiency of the Brayton cycle with supercritical CO2, which uses the sensible heat of syngas in the Rankine steam cycle. This cycle, with 98.1% CO2 capture, has 40.6% net efficiency. IGCC, based on the same gasifier, captures about 90% of CO2 and has 31.2% net efficiency. Thus, the transition to oxy-fuel combustion power cycles is reasonable from the points of view of efficient power production and environmental safety.
Investigations [20,21] propose the Allam cycle with coal gasification, wherein syngas sensible heat is used for power production in an additional carbon dioxide back-pressure turbine, and the turbine exhaust gas is supplied to a multi-flow regenerator. This technical solution allows cycle net efficiency of 43.7% at a carbon dioxide turbine inlet temperature of 1200 °C.
Numerous investigations have been concerned with the optimization of the Allam cycle’s parameters. The thermodynamic studies presented in [22,23,24] showed that the power facility reached its maximal efficiency at the following parameters: initial temperature and pressure of 1083 °C and 30 MPa, final pressure of 3 MPa, and cooling agent temperature of 200 °C. The prospective oxy-fuel combustion power cycle achieved 8.5% higher efficiency and 11–12-fold lower carbon dioxide emissions than the combined cycle facility with CCS.
Zhu Z. and Chen Y., et al. [25] discussed modifications to the Allam cycle, whereby the CO2 was compressed with pumps instead of compressors, which resulted in a 2.96% facility net efficiency improvement, up to 50.87%. Fernandes D. and Wang S., et al. [26] are devoted to exploring the influence of the type of oxidizer compression machine on the oxy-fuel facility’s efficiency.
An important feature of the Allam cycle is the integration of the air separation unit (ASU) into the cycle of supplying compressed hot air into the regenerative heat exchange system. That said, the utilization of low-potential heat sources, including the flow energy, in different compressors, has not yet been investigated. Therefore, this investigation aims to develop a highly efficient, oxy-fuel combustion power cycle that utilizes low-potential heat sources.

2. Research Objectives

This investigation’s starting point is the Allam cycle, wherein the low-potential heat of the ASU’s compressed air is used in a multi-flow heat exchanger. The main working fluid component of the cycle is carbon dioxide.
The cycle presented in Figure 1 operates as follows: The combustor is supplied with three flows, the fuel gas (CH4) is compressed in the fuel compressor, the oxidizer is produced in the ASU and compressed in the oxygen compressor, and the working fluid is heated in the multi-flow regenerator. The combustion of the oxy-fuel mixture in the carbon dioxide environment creates high-temperature products that enter the carbon dioxide turbine. These products drive the power generator and then enter the multi-flow regenerator, where they transfer some heat to the heated flows. Next, the flow is directed to the cooler–separator, where water and CO2 contents are split. After the cooler–separator, part of the carbon dioxide flow is compressed to supercritical pressure and is then sent to storage.
The main flow enters the multi-stage intercooled compressor. The compressed flow is split in two and directed towards the entrances of CO2 and CO2–O2 pumps. The inlet flow of pump CO2–O2 is pre-mixed with compressed oxygen. The high-pressure pumps’ exit flows enter the multi-flow regenerator and after heating, are directed toward to the combustor. The cycle is thus closed.
Table 1 summarizes the simulation input data for the oxy-fuel combustion power cycle. The data correspond to the optimization results presented in [26]. The fuel is pure methane, at an initial temperature and pressure of 15 °C and 0.7 MPa, respectively. The fuel burns in the 96.5% pure oxygen produced in the ASU. The carbon dioxide sent for storage has modeled pressure and temperature of 10 MPa and 28 °C, respectively [27].
Figure 2 shows the ASU producing oxygen for the combustor. Air is compressed in the axial compressor up to 0.7 MPa and then is cooled down to 25 °C and split into two flows. The main flow heads towards the nitrogen regenerators, and the other flow enters the oxygen regenerators. Downstream, the regenerator air is cooled to −172 °C, throttled, and supplied to the bottom rectifying column. In the column, the main air flow is separated at 0.55 MPa into the nitrogen reflux (with 99% nitrogen content) and the residue flow (with 62% nitrogen and 38% oxygen contents). Some air from the bottom column is supplied into the turbo-expander heat exchanger, where it is heated to 158 °C by the air flow.
In the turbo-expander, air expands to the pressure of the top column, which is 0.13 MPa, and enters the middle of the top column. At the same time, the residue flow and the nitrogen reflux produced in the bottom column heat the pure nitrogen exiting the top column in heaters, which is then throttled down to 0.13 MPa and supplied to the top column. In the top column, the air is finally separated into 99% pure nitrogen and 95.6% oxygen. This separation is carried out via the rectification process. The flow parameters are summarized in Table 2.

3. Methodology

Thermodynamic studies of oxy-fuel combustion power cycles were carried out using the AspenONE code. The simulation flowchart is shown in Figure 3, along with the flow parameters in Table 3. The scheme included an oxy-fuel combustion chamber; a cooled carbon dioxide turbine; a multi-flow regenerator; a cooler–separator; a multi-stage, intercooled compressor; oxygen, fuel and carbon dioxide compressors; and CO2 and CO2–O2 pumps. The thermo-physical performance of the operating fluid was calculated via the Peng–Robinson thermodynamic state equation.
The heat flow simulation involved a few assumptions. Particularly, the hydraulic losses in the elements’ connecting lines were assumed to be zero. Moreover, the combustion reaction was assumed to occur at a stoichiometric air–fuel ratio. The combustion products were water vapor and carbon dioxide:
CH 4 + 2 O 2 = 2 H 2 O + CO 2 + 892   kJ / mol
An open cooling scheme of the gas turbine compartment was proposed for the estimation of turbine cooling losses. If the difference between working fluid and blade wall temperatures was less than 300 °C, the convective cooling type was considered; otherwise, the film cooling type was adopted. In the model, the maximum acceptable average temperature of the blade metal outer surface was 850 °C.
The distribution of cooling agent between the turbine compartments and the cooling loss analysis are both described in [5,28]. The method described in [29] was selected for the estimation of specific coolant mass flow, or cooling flow ratio. According to the chosen method, the cooling flow fraction for each vane/blade row was defined as follows:
Ψ = K c o o l 1 + B ε 0 ε f [ 1 η i n t ( 1 ε 0 ) ] η i n t ( 1 ε 0 )
To estimate the vane/blade cooling effectiveness ε0 and the film-cooling effectiveness εf, the main flow and coolant temperatures were obtained from thermodynamic analysis of the oxy-fuel combustion cycle. A value of internal cooling efficiency ηint equal to 0.7 was considered for the calculation, which represented the current level of the internal cooling technology. To evaluate the cooling flow factor Kcool, the values of the required geometry parameters were obtained from 1D thermal and aerodynamic calculation of the CO2 turbine flow path. To estimate the coefficient B, the metal and TBC Biot numbers, equal to 0.3 and 0.15, correspondingly, were chosen, according to the recommendations in [29].
After determining the cooling flow factor for each turbine vane/blade row, the polytropic efficiency of the cooled stage was estimated with the method described in [30]:
η o i . i = ( k 1 k ) l o g ( P 02 P 01 ) l o g ( T 02 T 01 ) .
where k was the specific heat ratio, P01 was the total pressure at the stage inlet, P02 was the total pressure at the stage outlet, T01 was the total temperature at the stage inlet and T02 was the total temperature at the stage outlet.
The regenerative heat exchanging system is considered to be a combined multi-flow heat exchanger. These assumptions result in some overestimations of data, but a more accurate analysis may be carried out by following the detailed design of the equipment.
The analysis of the multi-flow regenerator had the following conditions:
  • The temperature difference in the pinch point was below 5 °C.
  • The turbine cooling agent’s temperature was 200 °C.
  • The minimal compressed air temperature at the exit of the regenerator was 30 °C.
  • The temperatures of all the heated flows, except that of the cooling agent flow at the regenerator exit, were equal.
The domestic power consumption for oxygen production was calculated with a developed model of cryogenic, low-pressure ASU. The model was created for the scheme presented on Figure 4a and allows evaluating influence of the following parameters upon ASU performance: oxygen mass flow rate (GO2, kg/s), produced oxygen purity (O2, %), ambient air temperature (tatm, °C), and compressor exit pressure (Pcomp.out, MPa). In this model, the compressor exit pressure corresponded with the assumed upper column pressure. The minimal and maximal oxygen purity degrees were assumed as 84% to 96 in this model, according to [31,32].
The ASU model was verified by the relationship of its power consumption and oxygen purity (Figure 4b). The calculated results were compared with the existing facility’s statistical data [33]; the level of results convergence was acceptable.
The ASU power consumption NASU (kW) may be calculated as follows:
N A S U = G O 2 e A S U ,
where GO2 is oxygen mass flow rate, kg/s and eASU is the specific ASU electricity consumption, kW/(kg/s).
The low potential heat QASU (MW) carried by the ASU exit airflow was calculated as follows:
Q A S U = G a i r c p . a i r ( T a i r . o u t T a i r . i n ) ,
where Gair was air mass flow rate, kg/s; cp.air was air specific heat capacity, kJ/kg·°C; Tair.out was the hot compressed air flow temperature from the ASU, °C; and Tair.in was the cold compressed air flow temperature to the ASU, °C.
The developed models of the oxy-fuel combustion power cycle and ASU were used for the thermodynamic analysis. The calculation results were compared with the research data presented in [22]. In the case of an initial temperature and pressure of 1150 °C and 30 MPa and a final pressure of 3 MPa, the cycle net efficiency mismatch was about 3.4%. The reason for such divergence was the usage of different models of the ASU and cooled gas turbine.

4. Results and Discussion

The potential sources of the low-potential heat to be utilized may be evaluated via the initial temperature level and the amount of heat carried by a flow. The evaluation results are shown in Figure 5 and Figure 6.
The compressed air flow had a maximum temperature of 241 °C (Figure 5) and a maximum thermal power of 29.4 MW. The oxygen flow potential was also high, with a temperature of 190 °C and a thermal power of 8.7 MW. Contrary to this, the compressed fuel supplied to the intermediate coolers at 127 °C and 3.6 MW had relatively low thermal power. As such, the further analyses considered only two sources with maximal potential: the compressed air and the oxygen. The carbon monoxide flow that was compressed in the multi-stage, intercooled compressor was not considered as a low-potential heat source because of its very low temperature (about 55 °C).
In the basepoint cycle (Figure 1) the low-potential heat of the compressed air flow from the ASU was utilized as the main source of heat, but it seemed reasonable to evaluate the improvement in net efficiency via the described changes. For this reason, the model shown in Figure 7 differs in the absence of the air flow supplied to the multi-flow regenerator. This cycle is similar to the E-MATIANT cycle [34,35].
The calculation results showed that the power unit’s net efficiency was increased following the utilization of the compressed air’s low-potential heat, from 47.7 to 51.2%. The low efficiency of the cycle shown in Figure 7 was caused by the insufficiency of the heat produced by the turbine exhaust gas for heating the regenerator’s cold flows. This was due to the difference in the thermal capacities of the heating and heated flows. The results were that the combustion chamber’s inlet flows were cold, and the mean integral heat supply temperature of the cycle was lower.
The high air temperature in the ASU increases the compression losses and finally raises the energy consumption of the oxygen production process. As such, for the cycle shown in Figure 7, it was reasonable to evaluate the influence of air intercooling in the ASU upon the cycle’s net efficiency. The analysis results showed that the two-stage intercooling process increased the cycle’s net efficiency to 48.6%, and the three-stage process increased it to 48.8%.
Besides this, the optimal separation pressure that allowed minimal losses in oxygen production in one-stage intercooling was 0.26–0.28 MPa (Figure 8), and the ASU compressor drive’s specific energy consumption dropped from 1093 to 976 kW s/kg.
In two-stage intercooling, the first and second coolers’ optimal pressures were 0.20–0.21 MPa and 0.36 MPa, respectively (Figure 9). In this case, the specific energy consumption of the ASU compressor drive dropped to 941 kW s/kg.
As such, the utilization of the heat of the ASU’s compressed air in the multi-flow regenerator facilitated greater improvement in cycle efficiency (up to 51.2%) than was achieved with the one-stage (up to 48.6%) and two-stage (up to 48.6%) processes of air intercooling with water.
The next assessment concerned the utilization of the compressed oxygen heat. An analysis of the cycle presented in Figure 1 showed that the regenerator did not require additional sources to the heat of the compressed air; as such, the oxygen heat should have been used for some other means: for example, in an additional cycle.
Figure 10 shows the Allam cycle utilizing the heat of the oxidizer in the Brayton cycle with recompression. The carbon dioxide heat carrier is employed because it balances the losses in the working fluid without any additional losses caused by the removal of some carbon dioxide flow from the main cycle.
The function of the additional carbon dioxide in the Brayton cycle with recompression is as follows: The heat sources are the oxygen compressor 4 inter-coolers 13 and 14, installed in parallel along the two operating fluid flows. The heat carrier flows of the heated carbon dioxide were mixed and directed into the turbine 15 inlet. The turbine drove electrical generator 16. The exhaust gas of the turbine 15 was supplied to heat exchangers 17 and 18 for sequential cooling. Downstream of heat exchanger 18, the carbon dioxide flow split into two. The majority was supplied to the pre-cooler 19, which then reduced the workload of compressor 20. This flow was compressed in compressor 20, entered heat exchanger 18, was therein heated, and was then mixed with the second smaller flow. The smaller flow was transported directly to compressor 21. After mixing, the combined working fluid flow was heated in heat exchanger 17 and then supplied to heat exchangers 13 and 14. As such, the cycle was closed.
According to the modeling results, utilization of the low-potential heat of compressed oxygen in a S–CO2 recompression Brayton cycle (Figure 10) increased the basepoint cycle (Figure 1) efficiency by 0.2%. In turn, the specific investment cost, including the price of CCS for the basic configuration of the high-power Allam cycle, was equal to 1307.5 $/kW, according to [23]. The specific investment cost of the low-power, supercritical CO2 recompression Brayton cycle is in a range of 1400 to 1600 $/kW (average value is 1500 $/kW), according to the research results presented in [36,37]. Therefore, the suggested modification of the Allam cycle, allowing for an increase in efficiency by 0.2%, leads to an increase of the specific investment cost by 4.5%. The total specific investment cost is equal to 1366.3 $/kW.

5. Conclusions

Accurate simulation models of oxy-fuel combustion power cycles were created using AspenONE software for thermodynamic analysis of the effects of utilizing various low-potential energy sources. The simulation results in the structural–parametric optimization of prospective gas-burning, oxy-fuel combustion power cycles.
In oxy-fuel combustion power cycles operating on super-critical carbon dioxide, certain sources of low-potential heat are available. Secondary utilization of the compressed air that is used for oxygen production in the regenerative heat exchanger improves net efficiency by 3.5%. The transferal of the compressed oxygen heat to the heat carrier in the Brayton cycle with recompression improves net efficiency by 0.2%. As such, low-potential heat utilization may improve the net efficiency of the cycle, with initial temperature and pressure of 1083 °C and 30 MPa and final pressure of 3 MPa, from 47.7 to 51.4%.
When low-potential heat is not utilized, it is possible to increase the cycle efficiency by 1.1% via the optimization of intercooling pressure in the air separation unit’s compressor; one-stage intercooling reduces the power consumption from 1093 to 976 kW s/kg and two-stage intercooling from 1093 to 941 kW s/kg.
The cycle modification solutions reviewed in this paper describe the effective utilization of low-potential heat, which may facilitate an improvement in the efficiency of known oxy-fuel combustion power cycles.

Author Contributions

Conceptualization, A.R. and N.R.; methodology, A.R. and V.K.; software, V.K. and A.V.; validation, V.K. and A.V.; formal analysis, O.Z.; investigation, A.R., V.K., and A.V.; resources, O.Z.; data curation, A.V.; writing (original draft preparation), V.K.; writing (review and editing), A.R. and O.Z.; visualization, A.V.; supervision, A.R. and N.R.; project administration, A.R.; funding acquisition, O.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This study was conducted by the Moscow Power Engineering Institute and was financially supported by the Ministry of Science and Higher Education of the Russian Federation (project no. FSWF-2020-0020).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Mauleon, I. Economic Issues in Deep Low-Carbon Energy Systems. Energies 2020, 13, 4151. [Google Scholar] [CrossRef]
  2. Eitan, A.; Rosen, G.; Herman, L.; Fishhendler, I. Renewable Energy Entrepreneurs: A Conceptual Framework. Energies 2020, 13, 2554. [Google Scholar] [CrossRef]
  3. Climent Barba, F.; Sanchez, G.M.D.; Segui, B.S.; Darabkhani, H.G.; Anthony, E.J. A Technical Evaluation, Performance Analysis and Risk Assessment of Multiple Novel Oxy-Turbine Power Cycles with Complete CO2 Capture. J. Clean. Prod. 2016, 133, 971–985. [Google Scholar] [CrossRef]
  4. Hamadeh, H.; Toor, S.Y.; Douglas, P.L.; Sarathy, S.M.; Dibble, R.W.; Croiset, E. Techno-Economic Analysis of Pressurized Oxy-Fuel Combustion of Petroleum Coke. Energies 2020, 13, 3463. [Google Scholar] [CrossRef]
  5. Rogalev, A.; Kindra, V.; Osipov, S.; Rogalev, N. Thermodynamic Analysis of the Net Power Oxy-Combustion Cycle. In Proceedings of the 13-th European Conference on Turbomachinery Fluid dynamics & Thermodynamics, Lausanne, Switzerland, 8–12 April 2019. [Google Scholar]
  6. Yang, H.J.; Kang, D.W.; Ahn, J.H.; Kim, T.S. Evaluation of Design Performance of the Semi-Closed Oxy-Fuel Combustion Combined Cycle. J. Eng. Gas Turb. Power 2012, 134, 111702. [Google Scholar] [CrossRef]
  7. Rogalev, A.; Kindra, V.; Zonov, A.; Rogalev, N.; Agamirov, L. Evaluation of Bleed Flow Precooling Influence on the Efficiency of the E-MATIANT Cycle. Mech. Mech. Eng. 2018, 22, 593–602. [Google Scholar] [CrossRef]
  8. Allam, R.; Martin, S.; Forrest, B.; Fetvedt, J.; Lu, X.; Freed, D.; Brown, G.; Sasaki, T.; Itoh, M.; Manning, J. Demonstration of the Allam Cycle: An Update on the Development Status of a High Efficiency Supercritical Carbon Dioxide Power Process Employing Full Carbon Capture. Energy Procedia. 2016, 114, 5948–5966. [Google Scholar] [CrossRef]
  9. Rodríguez Hervas, G.; Petrakopoulou, F. Exergoeconomic Analysis of the Allam Cycle. Energ. Fuel. 2019, 33, 7561–7568. [Google Scholar] [CrossRef]
  10. Zaryab, S.A.; Scaccabarozzi, R.; Martelli, E. Advanced Part-Load Control Strategies for the Allam Cycle. Appl. Therm. Eng. 2020, 168, 114822. [Google Scholar] [CrossRef]
  11. Sasaki, T.; Itoh, M.; Maeda, H.; Tominaga, J.; Saito, D.; Niizeki, Y. Development of turbine and combustor for a semi-closed recuperated Brayton cycle of supercritical carbon dioxide. In Proceedings of the ASME Power Conference, Charlotte, NC, USA, 26–30 June 2017; American Society of Mechanical Engineers: New York, NY, USA, 2017; p. V001T02A008. [Google Scholar]
  12. Rogalev, A.; Rogalev, N.; Kindra, V.; Vegera, A.; Zonov, A. Multi-stream heat exchanger for oxy-fuel combustion power cycle. AIP Conf. Proceedings 2021, 2323, 050001. [Google Scholar]
  13. Scaccabarozzi, R.; Gatti, M.; Martelli, E. Thermodynamic optimization and part-load analysis of the NET Power Cycle. Energy Procedia. 2017, 114, 551–560. [Google Scholar] [CrossRef]
  14. Martins, F.; Felgueiras, C.; Smitkova, M.; Caetano, N. Analysis of fossil fuel energy consumption and environmental impacts in European countries. Energies 2019, 12, 964. [Google Scholar] [CrossRef] [Green Version]
  15. Warner, K.J.; Jones, G.A. The 21-st century coal question: China, India, development, and climate change. Atmosphere 2019, 10, 476. [Google Scholar] [CrossRef] [Green Version]
  16. Allam, R.J.; Palmer, M.R.; Brown, G.W., Jr.; Fetvedt, J.; Freed, D.; Nomoto, H.; Itoh, M.; Okita, N.; Jones, C., Jr. High efficiency and low cost of electricity generation from fossil fuels while eliminating atmospheric emissions, including carbon dioxide. Energy Procedia 2013, 37, 1135–1149. [Google Scholar] [CrossRef] [Green Version]
  17. Hume, S. Performance evaluation of a supercritical CO2 power cycle coal gasification plant. In Proceedings of the 5-th International Symposium of Supercritical CO2 Power Cycles, San Antonio, TX, USA, 28–31 March 2016. [Google Scholar]
  18. Weiland, N.; Shelton, W.; White, C.; Gray, D. Performance baseline for direct-fired sCO2 cycles. In Proceedings of the 5-th International Symposium of Supercritical CO2 Power Cycles, San Antonio, TX, USA, 28–31 March 2016. [Google Scholar]
  19. Weiland, N.; White, C. Techno-economic analysis of an integrated gasification direct-fired supercritical CO2 power cycle. Fuel 2018, 212, 613–625. [Google Scholar] [CrossRef]
  20. Zhao, Y.; Zhao, L.; Wang, B.; Zhang, S.; Chi, J.; Xiao, Y. Thermodynamic analysis of a novel dual expansion coal-fueled direct-fired supercritical carbon dioxide power cycle. Appl. Energy 2018, 217, 480–495. [Google Scholar] [CrossRef]
  21. Zhao, Y.; Wang, B.; Chi, J.; Xiao, Y. Parametric study of a direct-fired supercritical carbon dioxide power cycle coupled to coal gasification process. Energy Convers. Manage. 2018, 156, 733–745. [Google Scholar] [CrossRef]
  22. Scaccabarozzi, R.; Gatti, M.; Martelli, E. Thermodynamic Analysis and Numerical Optimization of the NET Power Oxy-Combustion Cycle. Appl. Energy 2016, 178, 505–526. [Google Scholar] [CrossRef]
  23. Rogalev, A.; Grigoriev, E.; Kindra, V.; Rogalev, N. Thermodynamic Optimization and Equipment Development for a High Efficient Fossil Fuel Power Plant with Zero Emissions. J. Clean. Prod. 2019, 236, 117592. [Google Scholar] [CrossRef]
  24. Rogalev, A.; Rogalev, N.; Kindra, V.; Osipov, S. Dataset of Working Fluid Parameters and Performance Characteristics for the Oxy-Fuel, Supercritical CO2 Cycle. Data Brief 2019, 27, 104682. [Google Scholar] [CrossRef]
  25. Zhu, Z.; Chen, Y.; Wu, J.; Zhang, S.; Zheng, S. A Modified Allam Cycle without Compressors Realizing Efficient Power Generation with Peak Load Shifting and CO2 Capture. Energy 2019, 174, 478–487. [Google Scholar] [CrossRef]
  26. Fernandes, D.; Wang, S.; Xu, Q.; Buss, R.; Chen, D. Process and Carbon Footprint Analyses of the Allam Cycle Power Plant Integrated with an Air Separation Unit. Clean Technol. 2019, 1, 325–340. [Google Scholar]
  27. Gibbins, J.; Chalmers, H. Carbon Capture and Storage. Energy Policy 2008, 36, 4317–4322. [Google Scholar] [CrossRef] [Green Version]
  28. Rogalev, A.; Rogalev, N.; Kindra, V.; Komarov, I.; Zlyvko, O. Research and Development of the Oxy-Fuel Combustion Power Cycles with CO2 Recirculation. Energies 2021, 14, 2927. [Google Scholar] [CrossRef]
  29. Wilcock, R.C.; Young, J.B.; Horlock, J.H. The effect of turbine blade cooling on the cycle efficiency of gas turbine power cycles. J. Eng. Gas Turbine Power 2005, 127, 109–120. [Google Scholar] [CrossRef]
  30. Thorbergsson, E.; Grönstedt, T. A thermodynamic analysis of two competing mid-sized oxyfuel combustion combined cycles. J. Energy 2016, 2438431. [Google Scholar] [CrossRef] [Green Version]
  31. Kerry, F.G. Industrial Gas Handbook: Gas Separation and Purification, 1st ed.; CRC Press: Boca Raton, FL, USA, 2007; p. 550. [Google Scholar]
  32. Ebrahimi, A.; Meratizaman, M.; Reyhani, H.A.; Pourali, O.; Amidpour, M. Energetic, Exergetic and Economic Assessment of Oxygen Production from Two Columns Cryogenic Air Separation Unit. Energy 2015, 90, 1298–1316. [Google Scholar] [CrossRef]
  33. Van der Ham, L.V.; Kjelstrup, S. Exergy analysis of two cryogenic air separation processes. Energy 2010, 35, 4731–4739. [Google Scholar] [CrossRef]
  34. Mathieu, P.; Dubuisson, R.; Houyou, S.; Nihart, R. New concept of CO2 removal technologies in power generation, combined with fossil fuel recovery and long term CO2 sequestration. In Proceedings of the ASME Turbo Expo 2000: Power for Land, Sea, and Air, Munich, Germany, 8–11 May 2000; American Society of Mechanical Engineers: New York, NY, USA, 2000; p. V002T04A011. [Google Scholar]
  35. Mathieu, P. Towards the hydrogen era using near-zero CO2 emissions energy systems. Energy 2004, 29, 1993–2002. [Google Scholar] [CrossRef]
  36. Carlson, M.D.; Middleton, B.M.; Ho, C.K. Techno-economic comparison of solar-driven SCO2 Brayton cycles using component cost models baselined with vendor data and estimates. In Energy Sustainability; American Society of Mechanical Engineers: New York, NY, USA, 2017; Volume 57595, p. V001T05A009. [Google Scholar]
  37. Rao, Z.; Xue, T.; Huang, K.; Liao, S. Multi-objective optimization of supercritical carbon dioxide recompression Brayton cycle considering printed circuit recuperator design. Energy Convers. Manag. 2019, 201, 112094. [Google Scholar] [CrossRef]
Figure 1. The Allam cycle with low-potential heat of the air used in the multi-flow regenerator.
Figure 1. The Allam cycle with low-potential heat of the air used in the multi-flow regenerator.
Energies 14 03364 g001
Figure 2. The low-pressure ASU.
Figure 2. The low-pressure ASU.
Energies 14 03364 g002
Figure 3. Simulation flowchart.
Figure 3. Simulation flowchart.
Energies 14 03364 g003
Figure 4. ASU simulation model and results: (a) Model; (b) Dependence of the specific ASU electricity consumption on oxygen purity.
Figure 4. ASU simulation model and results: (a) Model; (b) Dependence of the specific ASU electricity consumption on oxygen purity.
Energies 14 03364 g004
Figure 5. Temperatures of the low-heat sources.
Figure 5. Temperatures of the low-heat sources.
Energies 14 03364 g005
Figure 6. Thermal power of the low-heat sources.
Figure 6. Thermal power of the low-heat sources.
Energies 14 03364 g006
Figure 7. The Allam cycle that does not utilize the low-potential heat of the compressed air from the ASU in the regenerator.
Figure 7. The Allam cycle that does not utilize the low-potential heat of the compressed air from the ASU in the regenerator.
Energies 14 03364 g007
Figure 8. Dependence of the specific energy consumption of an ASU compressor drive with a single-stage intercooled compressor.
Figure 8. Dependence of the specific energy consumption of an ASU compressor drive with a single-stage intercooled compressor.
Energies 14 03364 g008
Figure 9. Dependence of the specific energy consumption of an ASU compressor drive with a two-stage intercooled compressor.
Figure 9. Dependence of the specific energy consumption of an ASU compressor drive with a two-stage intercooled compressor.
Energies 14 03364 g009
Figure 10. The Allam cycle utilizing the low-potential heat of compressed oxygen in a S–CO2 recompression Brayton cycle.
Figure 10. The Allam cycle utilizing the low-potential heat of compressed oxygen in a S–CO2 recompression Brayton cycle.
Energies 14 03364 g010
Table 1. Cycle simulation input data.
Table 1. Cycle simulation input data.
ParameterValue
Turbine inlet temperature, °C1083
Turbine inlet pressure, MPa30
Turbine outlet pressure, MPa3
Turbine coolant temperature, °C200
CO2 compressor mass flow, kG/s600
Atmospheric pressure, MPa0.1
Atmospheric temperature, °C15
Atmospheric humidity, %60
Fuel typeCH4
Fuel temperature, °C15
Fuel pressure, MPa0.7
Fuel low heating value, MJ/kg50
CO2 storage pressure, MPa10
Turbine isoentropic efficiency, %90
Multi-stage, intercooled compressor isoentropic efficiency, %90
Fuel compressor isoentropic efficiency, %90
O2 compressor isoentropic efficiency, %90
CO2 compressor isoentropic efficiency, %90
Pumps isoentropic efficiency, %90
Temperature difference in the multi-flow regenerator pinch point, °C5
Turbine, generator, and compressor mechanical efficiency, %99
Pumps mechanical efficiency, %99
Power generator and electric motor mechanical efficiency, %99
Working fluid temperature at the cooler–separator exit, °C55
Working fluid temperature at the compressor intercooler exit, °C30
Oxygen purity, %95.6
Table 2. ASU flow parameters.
Table 2. ASU flow parameters.
Flow NoDescriptionMole Fraction, %Mass Flow Rate, kg/sTemperature, °CPressure, MPa
O2N2
1Air compressor inlet0.2090.791115
2Air compressor out 0.1
3Air after oxygen regenerator0.2090.7911300.589
4Air after nitrogen regenerator0.2090.7910.205−1720.574
5Air after mixing0.2090.7910.795−1720.574
6Air after turbo-expander heat exchanger hot side0.2090.7911−1720.574
7Air after lower column0.2090.7910.115−1130.574
8Air in nitrogen heater0.2090.7910.248−1730.574
9Air from nitrogen heater0.2090.7910.011−1730.574
10Air in turbo-expander from heat exchanger cold side0.2090.7910.011−175.5
11Air after turbo-expander0.2090.7910.248−1580.539
12Crude liquid oxygen from lower column0.2090.7910.248−1880.13
13Crude liquid oxygen from heater0.380.620.404−1740.56
14Nitrogen reflux from lower column0.380.620.404−176.50.130
15Nitrogen reflux from heater0.010.990.348−1780.55
16Nitrogen from upper column0.010.990.348−191.30.13
17Oxygen from upper column0.990.010.790−193.80.125
18Nitrogen from nitrogen heater0.9560.0440.210−1780.135
19Nitrogen output0.990.010.790−1780.1175
20Oxygen for Allam cycle0.990.010.790260.0975
Table 3. Simulation flow parameters.
Table 3. Simulation flow parameters.
Flow NoDescriptionMass Fraction, %Mass Flow Rate, kg/sTemperature, °CPressure, MPa
CH4O2N2CO2H2O
1Fuel compressor inlet1----7.33150.7
2Fuel compressor outlet1----7.33147.930
3Oxygen compressor inlet-1---29.3260.1175
4Oxygen compressor outlet-1---29.3190.68
5Carbon dioxide turbine inlet---0.9740.026618.8108330
6Carbon dioxide turbine outlet -0.9750.025636.6703.33
7Cooler–separator inlet---0.9750.025636.6863
8Cooler–separator outlet---0.99750.0025621.7553
9Carbon dioxide storage---0.99750.002521.72810
10Multi-stage compressor inlet---0.99750.0025600553
11Multi-stage compressor outlet---0.99750.0025600308
12CO2 pump inlet---0.99750.0025328.2308
13Main CO2 flow in multi-flow regenerator---0.99750.0025310.474.330
14Main CO2 flow from multi-flow regenerator---0.99750.0025310.4658.630
15Coolant flow in multi-flow regenerator---0.99750.002517.874.330
16Coolant flow from multi-flow regenerator---0.99750.002517.820030
17CO2 flow for mixing with O2---0.99750.0025271.8308
18CO2–O2 pump inlet-0.097-0.90.003301.118.28
19CO2–O2 pump outlet-0.097-0.90.003301.180.630
20CO2-O2 at combustion chamber inlet-0.097-0.90.003301.1658.630
21Air from ASU compressor-0.2330.767--139.03241.40.589
22Air from multi-flow regenerator-0.2330.767--139.0379.30.589
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Rogalev, A.; Rogalev, N.; Kindra, V.; Zlyvko, O.; Vegera, A. A Study of Low-Potential Heat Utilization Methods for Oxy-Fuel Combustion Power Cycles. Energies 2021, 14, 3364. https://doi.org/10.3390/en14123364

AMA Style

Rogalev A, Rogalev N, Kindra V, Zlyvko O, Vegera A. A Study of Low-Potential Heat Utilization Methods for Oxy-Fuel Combustion Power Cycles. Energies. 2021; 14(12):3364. https://doi.org/10.3390/en14123364

Chicago/Turabian Style

Rogalev, Andrey, Nikolay Rogalev, Vladimir Kindra, Olga Zlyvko, and Andrey Vegera. 2021. "A Study of Low-Potential Heat Utilization Methods for Oxy-Fuel Combustion Power Cycles" Energies 14, no. 12: 3364. https://doi.org/10.3390/en14123364

APA Style

Rogalev, A., Rogalev, N., Kindra, V., Zlyvko, O., & Vegera, A. (2021). A Study of Low-Potential Heat Utilization Methods for Oxy-Fuel Combustion Power Cycles. Energies, 14(12), 3364. https://doi.org/10.3390/en14123364

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop