Effect of Environmental and Operating Conditions on Partial Discharge Activity in Electrical Machine Insulation: A Comprehensive Review

1
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
2
Department of Engineering and Applied Sciences, University of Bergamo, 24100 Bergamo, Italy
3
Key Laboratory of More Electric Aircraft Technology of Zhejiang Province, University of Nottingham Ningbo China, Ningbo 315100, China
*
Author to whom correspondence should be addressed.
Energies 2024, 17(16), 3980; https://doi.org/10.3390/en17163980 (registering DOI)
Submission received: 12 July 2024 / Revised: 5 August 2024 / Accepted: 8 August 2024 / Published: 11 August 2024
(This article belongs to the Section F: Electrical Engineering)

Abstract

: Electrical machines for transportation applications are subjected to harsh environmental conditions during their operations. Partial discharge (PD), which is one of the main reasons for insulation failure, is greatly affected by ambient conditions (i.e., temperature, pressure, and humidity). Countless efforts are made for a comprehensive understanding of the physics of PD under variable environmental factors. This paper aims to review recent works addressing temperature, pressure, and humidity impact on PD activity. The main content of the paper is organized into three sections dealing with each environmental factor. In every section, relevant publications are reviewed considering the type of samples tested, voltage waveform applied, mutual effects, and the most common PD modeling strategies used. The applicability of the PD measurements for PD risk assessment is also discussed. Based on the review, the current progress in understanding the environmental effects on the PD inception mechanism and PD characteristics is presented and discussed in detail, and future research trends in this field are outlined.
Keywords: partial discharge; temperature; pressure; humidity; electrical machines; electrical insulation system; transportation electrification partial discharge; temperature; pressure; humidity; electrical machines; electrical insulation system; transportation electrification

Share and Cite

MDPI and ACS Style

Ji, Y.; Giangrande, P.; Zhao, W. Effect of Environmental and Operating Conditions on Partial Discharge Activity in Electrical Machine Insulation: A Comprehensive Review. Energies 2024, 17, 3980. https://doi.org/10.3390/en17163980

AMA Style

Ji Y, Giangrande P, Zhao W. Effect of Environmental and Operating Conditions on Partial Discharge Activity in Electrical Machine Insulation: A Comprehensive Review. Energies. 2024; 17(16):3980. https://doi.org/10.3390/en17163980

Chicago/Turabian Style

Ji, Yatai, Paolo Giangrande, and Weiduo Zhao. 2024. "Effect of Environmental and Operating Conditions on Partial Discharge Activity in Electrical Machine Insulation: A Comprehensive Review" Energies 17, no. 16: 3980. https://doi.org/10.3390/en17163980

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Article metric data becomes available approximately 24 hours after publication online.
Back to TopTop