Next Issue
Volume 7, February
Previous Issue
Volume 6, April
 
 
Audiology Research is published by MDPI from Volume 10 Issue 2 (2020). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with PAGEPress.

Audiol. Res., Volume 6, Issue 2 (August 2016) – 6 articles

  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list.
  • You may sign up for e-mail alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.
Order results
Result details
Select all
Export citation of selected articles as:
715 KiB  
Article
Multicentre Evaluation of the Naída CI Q70 Sound Processor: Feedback from Cochlear Implant Users and Professionals
by Jeanette Martin, Christine Poncet-Wallet, Angelika Illg, Sarah Perrin-Webb, Lise Henderson, Nathalie Noël-Petroff, Gennaro Auletta, Maria Grazia Barezzani, Karim Houri, Indian Research Group, Heike Bagus, Ulrich Hoppe, Jane Humphries, Wiebke van Treeck, Jeroen J. Briaire, Martina Brendel and Nathalie Mathias
Audiol. Res. 2016, 6(2), 160; https://doi.org/10.4081/audiores.2016.160 - 22 Dec 2016
Cited by 3 | Viewed by 1055
Abstract
The aim of this survey was to gather data from both implant recipients and professionals on the ease of use of the Naída CI Q70 (Naída CI) sound processor from Advanced Bionics and on the usefulness of the new functions and features available. [...] Read more.
The aim of this survey was to gather data from both implant recipients and professionals on the ease of use of the Naída CI Q70 (Naída CI) sound processor from Advanced Bionics and on the usefulness of the new functions and features available. A secondary objective was to investigate fitting practices with the new processor. A comprehensive user satisfaction survey was conducted in a total of 186 subjects from 24 centres. In parallel, 23 professional questionnaires were collected from 11 centres. Overall, there was high satisfaction with the Naída CI processor from adults, children, experienced and new CI users as well as from professionals. The Naída CI processor was shown as being easy to use by all ages of recipients and by professionals. The majority of experienced CI users rated the Naída CI processor as being similar or better than their previous processor in all areas surveyed. The Naída CI was recommended by the professionals for fitting in all populations. Features like UltraZoom, ZoomControl and DuoPhone would not be fitted to very young children in contrast to adults. Positive ratings were obtained for ease of use, comfort and usefulness of the new functions and features of the Naída CI sound processor. Seventy-seven percent of the experienced CI users rated the new processor as being better than their previous sound processor from a general point of view. The survey also showed that fitting practices were influenced by the age of the user. Full article
221 KiB  
Article
Item Response Theory Applied to Factors Affecting the Patient Journey towards Hearing Rehabilitation
by Michelene Chenault, Martijn Berger, Bernd Kremer and Lucien Anteunis
Audiol. Res. 2016, 6(2), 159; https://doi.org/10.4081/audiores.2016.159 - 30 Nov 2016
Cited by 4 | Viewed by 782
Abstract
To develop a tool for use in hearing screening and to evaluate the patient journey towards hearing rehabilitation, responses to the hearing aid rehabilitation questionnaire scales aid stigma, pressure, and aid unwanted addressing respectively hearing aid stigma, experienced pressure from others; perceived hearing [...] Read more.
To develop a tool for use in hearing screening and to evaluate the patient journey towards hearing rehabilitation, responses to the hearing aid rehabilitation questionnaire scales aid stigma, pressure, and aid unwanted addressing respectively hearing aid stigma, experienced pressure from others; perceived hearing aid benefit were evaluated with item response theory. The sample was comprised of 212 persons aged 55 years or more; 63 were hearing aid users, 64 with and 85 persons without hearing impairment according to guidelines for hearing aid reimbursement in the Netherlands. Bias was investigated relative to hearing aid use and hearing impairment within the differential test functioning framework. Items compromising model fit or demonstrating differential item functioning were dropped. The aid stigma scale was reduced from 6 to 4, the pressure scale from 7 to 4, and the aid unwanted scale from 5 to 4 items. This procedure resulted in bias-free scales ready for screening purposes and application to further understand the help-seeking process of the hearing impaired. Full article
557 KiB  
Article
Impact of Different Cutoff Criteria on Rate of (Central) Auditory Processing Disorders Diagnosis Using the Central Test Battery
by Mohsin Ahmed Shaikh, Lisa Fox-Thomas and Denise Tucker
Audiol. Res. 2016, 6(2), 158; https://doi.org/10.4081/audiores.2016.158 - 25 Nov 2016
Cited by 5 | Viewed by 738
Abstract
The purpose of this study was to quantify how the use of two different cutoff criteria affects the test failure rate and potential diagnosis of central auditory processing disorder ([C]APD) in a sample of children subjected to central auditory processing ([C]AP) assessment. Test [...] Read more.
The purpose of this study was to quantify how the use of two different cutoff criteria affects the test failure rate and potential diagnosis of central auditory processing disorder ([C]APD) in a sample of children subjected to central auditory processing ([C]AP) assessment. Test failure rates for the central test battery (CTB) using two different cutoff criteria (1 and 2 SDs below the mean) were measured retrospectively for 98 children who completed (C)AP assessment. The rates of potential (C)APD diagnosis ranged from 86.8% [when a 1 standard deviation (SD) cutoff was used] to 66.2% (when a 2 SD cutoff was used). The current use of two different cutoffs for the CTB has a large impact on the diagnostic rate for (C)APD. These findings have clinical implications for the diagnosis of (C)APD due to the widespread use of the CTB in the United States for the assessment of (C)APD in children. Thus, it is important to create awareness among audiologists that use of the 2 SDs cutoff criterion is recommended for reducing false positives (error). Full article
609 KiB  
Brief Report
New Treatment Strategy for Apogeotropic Horizontal Canal Benign Paroxysmal Positional Vertigo
by Francisco Zuma e Maia
Audiol. Res. 2016, 6(2), 163; https://doi.org/10.4081/audiores.2016.163 - 24 Nov 2016
Cited by 33 | Viewed by 1224
Abstract
The apogeotropic variant of horizontal semicircular canal benign paroxysmal positional vertigo (HC-BPPV) is attributed to canalithiasis of the anterior arm or cupulolithiasis. Despite some therapeutic maneuvers, I propose a new treatment strategy for apogeotropic HCBPPV that is designed to detach both the otoconial [...] Read more.
The apogeotropic variant of horizontal semicircular canal benign paroxysmal positional vertigo (HC-BPPV) is attributed to canalithiasis of the anterior arm or cupulolithiasis. Despite some therapeutic maneuvers, I propose a new treatment strategy for apogeotropic HCBPPV that is designed to detach both the otoconial debris from the anterior arm of the semicircular canal and the debris that is attached to the utricular side of the cupula using inertia and gravity and based on simulations with a 3D biomechanical model. Full article
593 KiB  
Article
An Exploratory Study Identifying a Possible Response Shift Phenomena of the Glasgow Hearing Aid Benefit Profile
by Jonathan Arthur, Tessa Watts, Ruth Davies, Vinaya Manchaiah and Julie Slater
Audiol. Res. 2016, 6(2), 152; https://doi.org/10.4081/audiores.2016.152 - 24 Nov 2016
Cited by 3 | Viewed by 1352
Abstract
A then-test technique was used to investigate the possibility of a response shift in the Glasgow hearing aid benefit profile (GHABP). Following completion of part 1 of the GHABP, 16 adults were invited for hearing-aid follow up appointments. In accordance with then-test technique, [...] Read more.
A then-test technique was used to investigate the possibility of a response shift in the Glasgow hearing aid benefit profile (GHABP). Following completion of part 1 of the GHABP, 16 adults were invited for hearing-aid follow up appointments. In accordance with then-test technique, participants were asked to think back to before they had their hearing-aids fitted and the GHABP part 1 was completed again to re-establish the disability and handicap scores. These scores were then compared with the initial GHABP part I scores. Paired T testing and Wilcoxon Rank tests were carried out to investigate the statistical significance of the response shift effect. Statistically significant differences were seen between initial and retrospective GHABP (disability) scores using t test. No significant differences could be seen between the initial and retrospective handicap scores. Results suggest participants may have demonstrated a possible response shift phenomenon with the disability construct of the GHABP questionnaire, related to a possible re-calibration effect or a denial of disability effect. This exploratory study suggests that the GHABP questionnaire may be subject to a response shift phenomena. We suggest that further more robust studies are completed to verify this and recommend that this could have psychological impact on participants when explaining the results of the outcome measure and may affect hearing aid use. There is also potential for this phenomenon to affect global GHABP scores specifically when demonstrating to stakeholders the overall success of an audiology service. Full article
1057 KiB  
Article
Transient Noise Reduction in Cochlear Implant Users: A Multi-Band Approach
by Karl-Heinz Dyballa, Phillipp Hehrmann, Volkmar Hamacher, Thomas Lenarz and Andreas Buechner
Audiol. Res. 2016, 6(2), 154; https://doi.org/10.4081/audiores.2016.154 - 23 Aug 2016
Cited by 5 | Viewed by 847
Abstract
A previously-tested transient noise reduction (TNR) algorithm for cochlear implant (CI) users was modified to detect and attenuate transients independently across multiple frequency-bands. Since speech and transient noise are often spectrally distinct, we hypothesized that benefits in speech intelligibility can be achieved over [...] Read more.
A previously-tested transient noise reduction (TNR) algorithm for cochlear implant (CI) users was modified to detect and attenuate transients independently across multiple frequency-bands. Since speech and transient noise are often spectrally distinct, we hypothesized that benefits in speech intelligibility can be achieved over the earlier single- band design. Fifteen experienced CI users (49 to 72 years) were tested unilaterally using pre-processed stimuli delivered directly to a speech processor. Speech intelligibility in transient and soft stationary noise, subjective sound quality and the recognition of warning signals was investigated in three processing conditions: no TNR (TNRoff), single- band TNR (TNRsgl) and multi-band TNR (TNRmult). Notably, TNRmult improved speech reception thresholds (SRTs) in cafeteria noise and office noise by up to 3 dB over both TNRoff and TNRsgl, and yielded higher comfort and clarity ratings in cafeteria noise. Our results indicate that multi-band transient noise reduction may be advantageous compared to a single-band approach, and reveal a substantial overall potential for TNR to improve speech perception and listening comfort in CI users. Full article
Previous Issue
Next Issue
Back to TopTop