1. Introduction
Due to rising fuel prices and stricter greenhouse gas emission regulations, reducing fuel consumption and emissions has become an endeavor for the internal combustion engine industry [
1,
2,
3,
4]. For example, the European Union has set a 37.5% reduction in fuel consumption for passenger cars by 2030 compared to 2021. For the internal combustion engine itself, stringent emission regulations and rising fuel control requirements have prompted the internal combustion engine industry to develop more advanced technologies [
5,
6,
7,
8]. To achieve this goal, exhaust gas turbochargers, a key component of the internal combustion engine’s air exchange system, could play a particularly important role. Similarly, the studies of alternative liquid fuels also need to consider the effect of the turbocharger [
9]. The turbocharger and the engine match and interact with each other, and the operating characteristics of the engine must be considered while studying the turbocharger [
10].
On account of the exhaust characteristics of the engine, the turbocharger turbine operates in an exhaust gas pulse environment where the turbine inlet pressure and temperature change periodically [
11,
12]. Under pulsed, unsteady conditions, the turbine mostly operates in deviation from the design point condition and even in a zero-admission condition [
13]. Copeland et al. [
14] studied the difference between the unsteady and steady flow performance of a separated twin-entry turbine, and the steady flow efficiency was found to be higher than the unsteady flow efficiency. Moreover, Rajoo [
15] showed in his study that the pulsed, unsteady average efficiency of the turbine deviated from the corresponding quasi-steady efficiency value by up to 32%, indicating that the steady approach was inaccurate.
The automotive turbocharger pulse boost system sets the turbine to work in the engine’s periodic pulse, unsteady exhaust environment; the admission condition at the turbine end changes continuously, and the performance of the turbine further changes periodically with the change in the intake state at the turbine end. Multi-fluid turbine structures and various boost systems have emerged to improve the utilization of pulse energy [
16,
17]. Currently, the swallowing capacity and efficiency of a turbine can be easily improved by using a twin-entry turbine instead of a single-entry turbine [
15]. Other research studies that have focused on the use of single-entry turbine are include [
18,
19,
20]. Cerdoun [
21] investigated the unsteady flow process in an asymmetric parallel twin-entry turbine and concluded that increasing the radius of the volute shape could enhance the centrifugal force of the airflow. In addition, Chiong MS [
22,
23] studied a one-dimensional (1D) numerical model of a twin-entry turbine under full admission pulse flow conditions and predicted the corresponding performance. The full admission condition of the twin-entry turbine occurs only momentarily, and the turbine operates with unequal admission [
24,
25,
26].
In terms of unequal admission conditions, Newton [
27] employed a computational fluid dynamics (CFD) software to investigate the flow loss of a twin-entry turbine under full and partial admissions. Costall [
28] developed a twin-entry turbine model, which could be used as a simplified single-entry model under full admission conditions, while a more complex model is required for unequal admission conditions. Hajilouy [
29] investigated the performance and internal flow field characteristics of a twin-entry turbine under full and extreme admission conditions. Other studies [
30,
31] have also performed the same experiment, and revealed the mechanism of the influence of the volute structure on the turbine performance.
The compressor is also the key component of the turbocharger, which directly determines the turbocharger performance, as well as the matching performance of the turbocharger and the engine. The compressor is affected by the fluctuation of the engine admission, which makes the flow rate and pressure of the compressor periodically change with the engine operating process. This could further affect the engine performance; for example, the compressed air supercharging system could improve the driving force during the phase of the engine’s increasing crankshaft rotational speed [
32]. The works of [
33] and [
34] presented the periodic changes in air flow at the inlet and outlet of the compressor. Other studies related to the compressor of a turbocharger can be found in [
35,
36,
37].
The performance of turbochargers in a harsh working environment of high temperature and high pressure for a long time will directly affect the performance of an engine. Fan proposed a novel Adaptive Local Maximum-Entropy Surrogate Model, carried out a turbine disk reliability analysis under geometrical uncertainty, and achieved a desirable result [
38]. Meng constructed a smooth response surface of the turbine performance by the saddlepoint approximation reliability analysis method and solved a turbine blade design problem [
39].
As can be seen from the brief description above, the actual operation of the booster has a non-constant flow at both ends, and the difference between the non-constant flow performance and the corresponding constant flow value is obvious. The performance at both ends of the turbocharger is limited by the structural properties of another end, and a complete performance map is usually unavailable [
40]. Meanwhile, the current conventional method of calculating the total efficiency of a turbocharger is to multiply the turbine efficiency, the compressor efficiency, and the turbocharger mechanical efficiency [
41]. This calculation method is not objective enough, because the maximum efficiency points of the turbine and compressor are often not in the same operating condition. Moreover, the operation of the turbocharger is a dynamic process of speed change, and the actual efficiency of both the turbine and the compressor is dynamically changing, therefore there are different total efficiencies of the turbocharger for different operating conditions. The internal matching of the compressor to the turbine fundamentally determines the actual operating performance of the turbocharger and the matching performance between the turbocharger and the engine.
There is no in-depth and systematic research on the internal matching between the compressor and turbine, and the important role of the internal matching of their joint, in the design of turbochargers, is not fully reflected. In this study, a combination of experimental and numerical simulations was used to study different turbine structures, and GT-Power and ANSYS CFX were used as the simulation platforms. First, an automotive engine turbocharger turbine was studied and verified. Second, different volutes and turbine impellers with different numbers of blades were designed to produce different turbine structures, and simulations were performed to compare the new turbine structure with the original turbine and determine the differences between the conventional evaluation method and new method. Lastly, different turbine structures were evaluated using our new method, and the best turbine structure was identified. Following this, the corresponding superposition of the compressor power consumption curve and turbine effective power curve were coupled. A new method for optimizing the actual operating performance of the turbine from the perspective of joint matching between the compressor and turbine was proposed. The turbine performance optimized by the two methods was compared, and the new optimization method was proven to be effective and feasible when using equal and unequal admission experiments. The evaluation process and correction method used in this study can provide a future reference for the research and optimal design of turbocharger turbines.
Figure 1 shows the framework structure of this paper.
3. Results
3.1. Coupling of Internal Joint Operating Curves
The compressor and turbine are rigidly connected by the rotor shaft. They have the same speed, and their working states are related to the operation of the engine. The following three are the basic conditions for the operation of the booster:
Speed balance: the compressor, turbine, and rotor shaft have the same speed.
where
is the compressor speed (rpm),
is the turbine speed (rpm), and
is the rotor shaft speed (rpm);
Flow rate balance: the compressor working mass flow rate plus the engine fuel mass flow rate is equal to the turbine working mass flow rate, and this flow rate balance condition is also followed when the turbine bypass valve is opened.
where
is the turbine operating flow rate (kg/s),
is the compressor operating flow rate (kg/s), and
is the fuel flow rate (kg/s);
Power balance: The power transfer from the turbine side to the compressor side will lose part of the power, which includes turbine rotor lubrication and cooling losses, as well as the heat radiation of the components and other losses. The turbine power output minus this loss is equal to the compressor power consumption.
where
is the turbine output power (kW),
is the compressor power consumption (kW), and
is the power loss during energy transfer (kW).
The turbocharger operation must comply with Equations (1)–(3). This shows that the matching of the turbocharger to the engine contains three aspects: the matching of the compressor to the engine, the matching of the turbine to the engine, and the internal matching between the compressor and turbine of the turbocharger [
48].
In the fixed-speed line, the compressor power consumption curve and turbine effective power curve were superimposed and coupled. The intersection point of both the compressor and turbine at the time of coupling was the compressor flow rate, and the intersection point of the power balance was obtained, as shown in
Figure 5.
In comparison, the compressor power consumption curves and turbine effective power curves for all speeds were superimposed and coupled to obtain the joint operation points of the turbocharger at each speed, as shown in
Figure 6a. Connecting each joint operation point in turn formed the complete turbocharger joint operation curve for the condition of the turbine bypass valve being closed, as shown in
Figure 6b. The parameters in
Figure 5 and
Figure 6 are for the common operating conditions of the matched engine, and the parameter ranges are from the engine calibration and turbocharger map.
Furthermore, the turbocharger joint operation curve was the joint operation matching curve between the compressor and the turbine. When matching a turbocharger with an engine, following the turbocharger joint operating curve must be prioritized. The joint operation curve reflects the matching performance between the turbocharger and the engine, which helps to simplify matching the work between the turbocharger and the engine and improves the matching accuracy.
3.2. Turbine Optimization Evaluation Method
The performance parameters were described and compared in the research. The data related to these parameters were obtained from experiments and CFD simulations. The turbine performance parameters mainly include the expansion ratio, efficiency, output power, etc. The expansion ratio reflects turbine swallowing capacity. Different parameters have different effects on turbine performance, and the calculation formula is shown in Equation (4), where variable parameters
,
, and
are the corresponding performance weights, and the calculated turbine performance index,
, is a dimensionless value.
here,
P is the joint point output power,
π is the joint point expansion ratio,
is the joint point efficiency,
T1 refers to the original turbine, and
T2 refers to the modified turbine.
For the weight distribution of each parameter, the role of the turbine is to extract more engine exhaust gas energy and transfer it to the coaxial compressor; moreover, the turbine output power directly determines the distribution of the joint operating curve. Therefore, the weight distribution of the turbine output power is the largest. The swallowing capacity is the parameter that must be guaranteed by the turbine with the second highest weight, while the turbine efficiency weight is the last consideration.
Table 4 lists the weight assignment of each performance parameter.
3.3. Analysis of Turbine Impeller Blade Number Based on Joint Point
Five groups of turbine impellers with blade numbers of 8, 9, 10, 11, and 12 were designed, and the 3D modeling of each group was kept consistent with that of the original turbine. The same topology and meshing method were used for the impeller models, and the optimization study was carried out at 150,000 rpm.
The turbine was evaluated based on the conventional method, which compares the turbine performance curves as one component rather than favoring the joint points.
Figure 7 shows the effect of different blade numbers on the turbine performance, and all the turbine joint points are marked in the figure.
The output power, expansion ratio, and efficiency of the turbine decreased significantly at 150,000 rpm when the number of blades was lower than nine, which indicated that the number of turbine impeller blades should not be too small. When the number of blades was greater than nine, the turbine performances were very close.
This indicated that there was no significant difference in performance between the turbine structures for blade numbers greater than 9. Therefore, based on the conventional evaluation method, the number of turbine impeller blades could be reduced from 11 to 9 blades to reduce the turbine rotor mass and improve the turbocharger response characteristics without any significant reduction in the overall turbine performance.
The turbine was evaluated based on the joint point, and the output power and efficiency near the joint point of the nine-blade turbine were found to be lower than those of the original turbine at all speeds.
Table 5 shows the joint point performance comparison of turbines with different numbers of blades based on a single-entry volute. With reference to the performance of the original turbine, the turbine performance changed with the number of blades. Whether the number of impeller blades was greater than 11 or less than 11, the turbine performance index was less than that of the original turbine. When the number of impeller blades was less than nine, the turbine performance index decreased significantly, in terms of turbine output power and efficiency. The nine-blade turbine performance was different from the 11-blade original turbine performance based on the joint point performance evaluation, and the turbine impeller blade number could not be reduced. For a single-entry turbine, the number of the original turbine blades was reasonable. This differed from the conclusions of the conventional method evaluation.
Flow field analysis was performed for the mid-speed joint point, and
Figure 8 shows the entropy increase distribution at 80% leaf spread height of the impeller channel, with different numbers of blades at the mid-speed joint point. The lower the number of blades, the higher the entropy downstream of the blade channel was, and the larger the region of high entropy. The high entropy area near the suction surface of the blades increased significantly compared with the original turbine when the number of impeller blades was nine. The circumferential flow field of the impeller was not uniformly distributed, indicating that the internal flow evidently became turbulent, and that the flow loss downstream of the blade channel increased significantly, thus reducing the efficiency of the turbine.
According to the turbine working principle, the flow efficiency is high in the blade channel, and the Mach number or relative velocity of the flow in the airflow direction increases. The greater the relative Mach number and the lower the absolute velocity, the smaller the turbine outlet residual velocity loss and the higher the efficiency at the exit of the blade.
The Mach number of each scheme at the inlet of the blade channel was equal in the middle and downstream position of the blade channel. The greater the number of blades, the greater the Mach number was, which implied that the better the utilization of exhaust gas energy, the smaller the corresponding absolute speed at the exit of the impeller, as shown in
Table 6. As seen in the following table, the difference in the absolute outlet velocity between blades 8 and 9 was large. Therefore, the number of turbine impeller blades could be reduced within a reasonable range to reduce the rotor mass.
3.4. Comparative Analysis of Engine Performance with Optimized Structure of Two Methods
The difference between the conventional method and the joint point-based turbine optimization method was verified using the GT model.
Figure 9 shows the 1D model constructed using GT-Power. The basic assumptions [
49] in this simulation are as follows:
The working fluid is a uniform state, and the air entering the cylinder and the residual exhaust gas are completely mixed instantaneously;
Air and mixed gas are considered ideal gases, and their thermodynamic parameters are affected by the temperature and composition of the gas;
A steady flow process has been regarded for the process of working fluid;
The import and export kinetic energy of the working fluid is negligible, and there is no leakage during the combustion process;
The combustion heat release process is regarded as a thermodynamic process in which the external heats the working fluid inside the system in accordance with the established heat release law.
Keeping the compressor of the original turbine unchanged, the number of turbine impeller blades was varied to obtain the external characteristic torque and BSFC distribution of the engine, as shown in
Figure 10. In the low- and medium-speed ranges of the engine, the output torque of the engine was significantly lower when matched with a nine-blade, single-entry turbine than when matched with the original turbine. Furthermore, the overall BSFC of the nine-blade, single-entry turbine was higher than that of the original turbine. Its maximum torque was 3.5% lower than that of the original turbine, and the minimum BSFC was 3.7% higher than that of the original turbine.
Reducing the number of turbine impeller blades reduced the engine power and fuel economy performance of the single-entry turbine. Therefore, the conclusion of reducing the number of turbine impeller blades obtained based on the conventional method was not reasonable, while the evaluation method based on the joint point performance could accurately predict the optimization trend of the number of turbine impeller blades.
3.5. Optimized Design of Twin-Entry Turbine Structure under the Equal Admission Conditions
A twin-entry volute was designed based on the single-entry volute of the original turbine to compare its performance with a single-entry turbine under the same conditions. The two air inlets of the twin-entry turbine used equal-flow balanced admission.
Figure 11 shows the performance comparison of two volute structures at 150,000 rpm. Compared to the single-entry turbine, the overall output of the twin-entry turbine was higher at the joint point. However, its expansion ratio was also higher, thus making the twin-entry turbine performance index only slightly greater than that of the original turbine. The performance indices of the 9-blade and 11-blade twin-entry turbines were equal at the joint point, indicating that the number of impeller blades could be reduced from 11 to 9 for the twin-entry turbine.
The output power of the twin-entry turbine was slightly higher than that of the single-entry turbine at the joint operating point, and there was no significant difference in the overall swallowing capacity. Furthermore, the efficiency of the joint point of the twin-entry turbine was slightly lower; however, the flow inside the impeller was more uniform. The overall performance of the joint point of the twin-entry turbine was slightly higher than that of the original turbine, and the joint point performance indices of the 9-blade and 11-blade, twin-entry turbines were equal. Therefore, the original 11-blade, single-entry turbine could be optimized to a 9-blade, twin-entry turbine, and the 9-blade, twin-entry turbine exhibited better response characteristics and a more stable operation.
Equal admission performance tests of the twin-entry turbine with different numbers of blades were conducted to illustrate the feasibility of optimizing the number of blades of the twin-entry turbine impeller.
Figure 12 shows the equal admission experimental comparison of the performance of the 11-blade and 9-blade, twin-entry turbines. The maximum difference between the two expansion ratios (of 2.0%) was located at the high evolution speed joint point. The maximum difference in the relative efficiency at the joint point was 1.5%. The output powers of the two were close to each other near the joint working condition; the maximum difference between them was 2.1% at the joint point of 150,000 rpm, and the absolute difference was less than 0.2 kW.
From the analysis of the equal admission test, it was found that the swallowing capacity, efficiency, and output power of the 11-blade and 9-blade, twin-entry turbines were relatively close near the joint operating conditions, and there was no obvious difference between the two performances, indicating that the number of blades of the twin-entry turbine impeller could be optimized from 11 to 9 blades, which was consistent with the optimization conclusion from the simulation.
3.6. Analysis of the Unequal Admission Performance of the Twin-Entry Turbine
The exhaust pipes of cylinders 1 and 2 were connected to the outer runner of the twin-entry turbine, and the exhaust pipes of cylinders 3 and 4 were connected to the inner runner. The comprehensive performance comparisons of the turbine in different states under unequal admission condition were carried out at 150,000 rpm, as shown in
Table 7. The output power of the twin-entry turbine had a significant advantage over the single-entry turbine, and its performance index was higher than that of the single-entry turbine. For the twin-entry turbine, the performance index was slightly larger for the outer runner.
Under unequal admission conditions, there was no significant difference in expansion ratio, efficiency, and output power overall between the 11-blade and 9-blade, twin-entry turbines with a fixed inlet. Therefore, the original 11-blade, single-entry turbine can be optimized to a 9-blade, twin-entry turbine with better performance.
The device for an unequal admission turbine inlet performance test was used to add a gasket at the inlet of the twin-entry turbine housing to cut off the flow rate to one inlet while the other inlet was normal. The unequal admission experiment of the twin-entry turbine swallowing capacity was carried out, as shown in
Figure 13. When the same runner was closed, the expansion ratios of the 11-blade and 9-blade turbines were very close to each other, which was the same as the simulated trend. For the same number of blades, the turbine expansion ratio of the inner runner admission was slightly smaller than that of the outer runner intake; however, the expansion ratio error of the inner and outer runner admission was within the allowable range, indicating that there was no significant difference in the swallowing capacity of the inner and outer runners, and the experimental trend agreed well with the simulation conclusion.
4. Discussion
Based on the above method, all the performance points of engine meet the joint operating point requirements. Keeping the compressor of the original structure unchanged, the turbine structure was varied to obtain the external characteristic torque and the BSFC distribution of the engine based on the joint operating points, as shown in
Figure 14. In the low- and middle-speed range of the engine, the output torque of the engine was significantly higher when matched with a twin-entry turbine than when matched with a single-entry turbine. However, its BSFC was lower than that of the single-entry turbine.
For the twin-entry volute, the torque and BSFC curves of the 11-blade and 9-blade turbines overlapped, showing no significant difference. Hence, the 9-blade impeller could replace the 11-blade impeller and significantly reduce the turbine rotor mass and improve the response characteristics of the turbocharger and engine. The maximum engine torque of the 9-blade, twin-entry turbine was 5.4% higher than that of the original engine, and its lowest BSFC was 2.1% lower than that of the original engine. It was seen that the 9-blade, twin-entry turbine could effectively improve the engine performance at low- and medium-speed, and that the turbine performance was significantly improved.
Figure 14 shows the results of the 1D engine performance simulation, which shows that the torque and BSFC are basically nonlinear. This conclusion has also been confirmed by Samuel et al. [
50] and Yusaf et al. [
51]. On the other hand, the turbine obtained by the optimization method based on the joint operating curve has no significant difference at high speed compared to the conventional method. However, the turbine with the new optimized method has improved torque and BSFC in the low and medium speed. In this operating region, engine torque was increased by up to 3.2% and BSFC was reduced by up to 1.1% compared to the turbine optimized by conventional methods.
5. Conclusions
In this study, according to the basic conditions of turbocharger internal operation, the turbocharger joint point was determined, and the internal joint operation curve was obtained. A turbine evaluation method was proposed based on the internal joint operation, and the number of impeller blades and turbine housing were selected for optimal application design. The following conclusions were obtained within the scope of this study:
- (1)
Based on the joint operating characteristics of the two ends of the turbocharger compressor and turbine, the internal joint operating curve of the turbocharger was coupled using the performance distribution of the compressor and turbine, which was closer to the actual situation and was more practical;
- (2)
The evaluation method based on the joint point performance could predict the optimization trend of the turbine more accurately. Based on the internal joint operation curve of the turbocharger, the number of turbine impeller blades was optimized compared with the conventional evaluation method. The 1D engine performance simulation showed that the engine power and fuel economy of the turbine structure optimized by the conventional method were worse than those of the original engine;
- (3)
The turbine based on joint point optimization has better overall performance under the unequal admission condition. The output power of the twin-entry turbine has a significant advantage over the original turbine. Under the unequal admission condition, the 11-blade and 9-blade, twin-entry turbines have a similar performance, and the optimized turbine with 9-blade outer runner has the best overall performance, which is 1.7% higher than the original turbine;
- (4)
The turbine structure determined using the optimization method showed clear advantages. The findings of the study were verified using performance tests. The engine 1D performance simulation further showed that the maximum torque of the engine with the 9-blade, twin-entry turbine was 5.4% higher than that of the original engine and that the minimum BSFC was reduced by 2.1%.
The analysis determined that the optimal turbocharger was a 9-blade, twin-entry turbine. The performance of the optimized turbocharger was verified using the turbocharger test and the engine 1D performance simulation results. In the low- and medium-speed operating regions, the engine torque was increased by up to 3.2%, and BSFC was reduced by up to 1.1% compared to the turbine optimized by conventional methods.
In this study, from the perspective of internal joint matching between the compressor and turbine, and by coupling the internal joint operation curve of the turbocharger, the optimization application study of the turbine was carried out with the objective of improving the performance of the turbocharger turbine under internal joint operation conditions. This optimization method can provide future reference for the research and design optimization of the turbocharger turbine.