1. Introduction
Biocides are used to suppress the growth of unwanted organisms. Coating materials of buildings are, for instance, enriched with algaecides and fungicides to protect them from algae and fungi attacks. Many materials also contain in-can preservatives to prevent bacterial growth before application. However, next to the many benefits that biocides bring, there are some significant drawbacks, especially when considering biocide toxicity to the natural environment [
1].
Wet weather conditions cause leaching of biocides from building materials into the surrounding environment [
2,
3]. In many urban areas, runoff is directed to man-made ponds designed to mitigate flooding and pollution carried by the stormwater [
4]. In addition to more traditional pollutants such as heavy metals and PAHs, the stormwater entering these ponds can contain considerable amounts of biocides, some of which exceed, for instance, the recommended annual average values of the European Water Framework Directive for priority substances in inland waters or the predicted-no-effect-concentrations [
5]. A number of studies acknowledge that a variety of organisms populate stormwater ponds [
6,
7,
8]. They can contribute to the biodiversity of the urban environment [
9]. However, organisms in these aquatic systems become exposed to elevated amounts of pollutants, which pose a risk to the ecosystem quality and diversity [
10].
Many biocides are algaecides, and hence affect organisms such as phytoplankton—the microscopic water column algae of the aquatic environment. Phytoplankton forms the basis of the aquatic food web [
11] and any effects on its density or community composition caused by the presence of pollutants could lead to changes in the entire food web. Similarly to many other pollutants, biocides can experience a number of changes while in the stormwater pond. They might become photodegraded, biodegraded, and adsorbed into particulate matter [
12]. The remaining bulk water biocide concentrations could have an impact on planktonic algae communities [
13]. The phytoplankton could furthermore be affected by biocide degradation products or by biocides bound to sediments when these are re-suspended by high water column turbulence. The biocides and their breakdown products could inhibit growth of certain algal species [
14]; change the taxonomic composition and thereby induce shifts in the algae community [
15]; or alter the biovolume of the taxonomic groups [
16].
Several studies have been carried out testing the effects of different pesticides and biocides on phytoplankton communities. For instance, [
16] investigated the effects of irgarol in an indoor pond mesocosm study and observed a decrease in phytoplankton abundance after application at concentrations of 1 and 5 µg L
−1. [
17] examined natural phytoplankton communities in outdoor mesocosms and their sensitivity to constant exposure of the herbicides atrazine (70 µg L
−1), isoproturon (14 µg L
−1), and diuron (5 µg L
−1). The authors observed changes in phytoplankton community composition, where chrysophytes and chlorophytes were found to be less sensitive to herbicide contamination compared to cryptophytes or diatoms. Reference [
18] investigated phytoplankton changes in Lake Geneva in response to herbicide contaminations. Hazardous concentrations for 5% of the species were found to be 0.03 µg L
−1 for terbutryn and 0.05 µg L
−1 for diuron.
While various studies provide evidence that biocide contamination might induce changes in freshwater phytoplankton communities, few have addressed the man-made aquatic ecosystems of stormwater ponds. The present study investigated whether natural phytoplankton communities of stormwater ponds reflect the presence of biocides at environmentally realistic concentrations. The community response was measured in terms of its taxonomic composition, abundance, and biovolume. The biocides and their concentrations were chosen to reflect what has previously been measured in the same systems, namely, terbutryn, diuron, carbendazim, and irgarol 1051 (cybutryne) in concentrations from 10 to 1000 ng L
−1 [
5,
19]. The responses of the phytoplankton communities were studied in two types of laboratory microcosms and one type of in-situ outdoor mesocosm.
2. Materials and Methods
Samples for the two laboratory microcosm experiments were collected from a residential stormwater pond located in Silkeborg, Denmark (56°11′39.3″ N, 9°32′56.9″ E). The in situ mesocosm study was carried out in the same pond. The Silkeborg pond was selected based on previous studies documenting considerable biocide loads received by this pond, building coating materials being one of the sources of origin [
5]. In the study, biocides terbutryn and irgarol in some stormwater samples were found to exceed the recommended annual average values of the European Water Framework Directive for priority substances in inland waters [
20]. Additionally, the measured median concentrations of biocides such as terbutryn and carbendazim were exceeding the predicted-no-effect-concentrations referred in [
21]. During dry weather, the pond holds 2.680 m
3 of water, has a surface area of 3.260 m
2, and has a maximum depth of 1 m, and the slope of the embankments is 20%. It is sub-divided into 3 sections by sand barriers that rise to approximately 0.2 m below the water surface. The barriers and part of the embankments are vegetated by primarily
Phragmites australis. The pond receives surface runoff from a residential area of 21.5 ha of which 33% contributes to the runoff.
Four biocides, which are typically found in stormwater ponds and measured at significant concentrations during some wet-weather events [
5,
19], namely, tebutryn (TB), diuron (DR), carbendazim (CD), and irgarol 1051 (cybutryne) (IRG) were selected for the study. The biocides were purchased from Sigma-Aldrich as a powder (Pestanal
®, analytical standards, Broendby, Denmark). Stock solutions were prepared for each compound and their mixture (MIX) using acetonitrile as a solvent and stored in a freezer until dosing into microcosms and mesocosms (0.01% final acetonitrile concentration in each microcosm and mesocosm).
2.1. Microcosm Setups
The two laboratory microcosm setups consisted of 18 individual microcosms each. In the first setup the microcosms held only a water phase, while the microcosms of the second setup held both sediments and water phase (
Figures S1 and S2, Supplementary Material). For both setups, the 18 microcosms were organized in two parallel rows and illuminated from the sides by LED lamps consisting of a number of red (254 W m
−2) and white (342 W m
−2) bulbs. The light energy was measured with a fiber-optic spectrometer (USB2000+, Ocean Optics, Dunedin, FL, USA) and a light-dark cycle of 12 h was selected for the experiments to mimic day-night changes. In order to prevent sample evaporation as much as possible, the microcosm setups were placed in a dark room where the measured average temperature was 18.7 °C and the relative humidity was 55–74%, as the microcosms from both setups were kept open throughout the experiment. No additional CO
2 source was used for the experiments.
For the water phase microcosms, samples were collected from several locations distributed around the shoreline of the pond. Collected water was mixed in large containers and 1 L of it was poured into each of the 18 microcosms (1 L glass bottles). For the sediment microcosms, sediment cores were collected by glass corers of 5 cm diameter around the shoreline of the stormwater pond at a similar depth. This way, sediment disturbance among samples was prevented, and it was assumed that the water column phytoplankton communities would be more alike in the microcosms. Furthermore, the slope of the pond is shallow (1:5), and sediments hence also accumulate on the slopes of the pond. The glass corers holding the sediments were placed in the same setup as the water phase microcosms and hence used directly as microcosms. As sediment levels were not even in all cores (microcosms), pond water was adjusted to achieve identical water depths (25 cm). Samples for both setups were collected in spring, April 2015.
For both setups, biocide solution was added to the microcosms aiming at final concentrations of 10, 100, and 1000 ng L−1 of each biocide: 0.1 mL of the prepared stock solution was injected into each water phase microcosm, and 50 µL into each sediment microcosm. Additionally, 3 columns were spiked to hold a mix of the 4 biocides at the same final concentrations of each biocide. Three microcosms were selected as controls where no biocides were added, but the same amount of acetonitrile as in other microcosms was injected. Acetonitrile was used as solvent to prepare biocide stock solutions because of their low/moderate solubility in water. The experiments were carried out for 10 days and the water of each microcosm was mixed once per day. The 10 days exposure time was chosen because of the water residence time in stormwater ponds, which in designs following Danish best engineering practices is around two weeks. If no biocide effect on phytoplankton communities was observed after 10 days of exposure at controlled laboratory conditions, it was not expected to be significant later on either. This was considered especially due to the typical water exchange in stormwater ponds happening on average shortly after this tested period of time. At the end of the experiment, water was collected from each microcosm and preserved with Lugol’s solution for later phytoplankton identification and enumeration (40 mL from each water phase microcosm and 20 mL from each sediment microcosm).
2.2. In Situ Mesocosm Setup
The mesocosm experiment was carried out in August 2015. Ten cylinders of 50 cm diameter and 100 cm of height, with an upper part made of transparent and flexible 2-mm polycarbonate plastic, and a lower part made of stainless steel, were positioned along the shoreline of the stormwater pond. The mecosoms were pressed into the pond bottom, so that most of each of the steel cylinders was in the sediment and approximately 20 cm of the polycarbonate cylinder was above the waterline (
Figure S3, Supplementary Material). The latter was done to avoid inflow of pond water during excessive rain and consequent water level fluctuations in the pond. The pond bottom was originally constructed as a 0.5 m layer of clay to avoid seepage, and pressing the cylinders into this clay layer consequently hindered water exchange through the bottom sediments. After positioning the mesocosms, they were left in the pond for several days to let the disturbed bottom sediment settle before dosing of biocides.
The water volume in the mesocosms was estimated and biocide stock solution was dosed into each to achieve final concentrations of 100 and 1000 ng L
−1 for every biocide individually. Two mesocosms were selected as controls where no biocides were added, but the same amount of acetonitrile as in other mesocosms was dosed. The experiment was run for 15 days in order to cover an average two-week water residence time in Danish stormwater ponds. According to Danish Meteorological Institute [
22], the average temperature of the month for the region where Silkeborg pond is located was 17 °C with the lowest temperature of 2.8 °C and highest of 27.6 °C. Sunshine hours during the experiment ranged from approximately 2 to 14 h per day.
To follow the biocide concentration throughout the experiment, 1 L water samples were collected from each mesocosm and from the pond itself right after biocide dosing and then continuously every 3 days. The samples were stored cool and dark until further analysis, which was carried out within 24 h. At the end of the experiment, an additional 40 mL of water was sampled from each mesocosm and from the pond and right after sampling preserved with Lugol’s solution for phytoplankton identification and enumeration.
Microcosms and mesocosms are referred to according to the amounts of biocides they received. For example, TB100 is a cosm that received 100 ng L−1 of terbutryn, while MIX10 is a cosm that received 10 ng L−1 of all 4 biocides. Cosms labeled Control 1, 2, and 3 did not receive biocides, but were in all other respect treated identically to cosms that received biocides.
2.3. Water Quality Parameters
The water quality parameters, such as total phosphorus (TP, µg L
−1), dissolved reactive phosphorus (DRP, µg L
−1), NO
3 + NO
2-N (µg L
−1), and chlorophyll-
a, were measured in all samples collected from the pond, and in each microcosm and mesocosm at the end of the experiment. For the mesocosm experiment, this was also done on day 9. Total and dissolved reactive phosphorus were measured according to methods adapted from Danish Standard 292 [
23] and Standard Methods 4500-P [
24], respectively. NO
3 + NO
2-N was measured according to Danish Standard 223 [
25]. Water samples for measurement of dissolved reactive phosphorus and NO
3 + NO
2-N were first filtered through 0.3 µm glass fiber filters. Chlorophyll-
a measurements were done as described in [
26]. Each analysis was carried out only once for each sample, except at the start of each experiment where triple determinations were made. During the mesocosm study, conductivity, pH, dissolved oxygen, and water temperature were measured in the pond (WTW, Multi 3430 set G), and in every mesocosm every 3 days until the end of the experiment.
2.4. Biocide Analysis
Bulk water background concentrations of the 4 biocides were measured before all experiments. At the end of each experiment, the remaining concentrations in the water phase were measured for every microcosm and mesocosm. Mesocosm biocide concentrations were additionally measured every 3rd day during the experiment.
Biocide concentrations were measured with an Ultimate 3000 HPLC system coupled to an MSQ Plus single quadrupole Mass Spectrometer (Thermo Scientific, Waltham, MA, USA). The compound separation was performed at 30 °C using a Synergy polar–RP column of 150 mm length, 2 mm ID, and 4 µm particle size (Phenomenex, Torrance, CA, USA). A multi-step gradient of MiliQ HPLC-grade water (A) with 0.1% formic acid and HPLC-grade acetonitrile (B) with 0.1% formic acid was used: 0–1 min 30% of eluent B, 1–10 min 30–90%, 10–14 min 90%, and 14–19 min 30%. All collected water samples were first filtered through 1.2 µm glass fiber filters to remove larger particles; 200–600 mL of filtered water was used for solid phase extraction (Sol Ex Octadecyl C18 cartridges), which was carried out with a Dionex Autotrace 280 fully automated system. The selected program consisted of the steps: (1) cartridge conditioning with 10 mL of acetonitrile and 10 mL MiliQ water; (2) sample load on the cartridges; (3) cartridge rinse with 10 mL of MiliQ water; (4) cartridge drying for 8 min; (5) stepwise soaking and collecting of the sample using acetonitrile and methanol as solvents. Samples with the lowest biocide concentration were evaporated under nitrogen gas to 1 mL. The evaporated samples were centrifuged at 11,000 rpm for 10 min before injection into the HPLC. Limits of detection (LOD) and quantification (LOQ) for the 4 biocides were: LOD: CD: 1.05 µg L−1; DR: 7.5 µg L−1; TB: 0.3 µg L−1; and IRG: 0.4 µg L−1. LOQ: CD: 3.5 µg L−1; DR: 25 µg L−1; TB: 1 µg L−1; and IRG: 1.3 µg L−1.
2.5. Phytoplankton Identification and Enumeration
Phytoplankton identification and enumeration were carried out with EVOS XL-Core and GX Optical XDS-3 inverted microscopes.
HydroBios or
KC-Denmark counting chambers were used and depending on sample richness, dilutions with demineralized water were made. The largest organisms were counted in the whole chamber at 100 × magnification, while smaller organisms were counted in transects at 400 × or 600 × magnification; 95% of a sample (by biovolume) was counted and taxa biovolume was estimated according to [
27,
28]. Organisms were identified and classified to genus or higher taxonomical levels using the keys by [
11,
29,
30,
31,
32,
33,
34,
35,
36,
37].
2.6. Statistical Analysis
Total numbers of organisms and biovolumes were grouped into different biocide treatment groups for each experimental study. One-way ANOVA tests in SigmaPlot version 12.3 [
38,
39,
40] were run to test whether there were any significant differences among the treatments by different biocides and their concentrations. Multivariate analysis, such as classical cluster analysis, DCA, and Bray–Curtis similarity and distance indices were carried out for each microcosm and mesocosm study using the program Past version 3.15 [
41,
42]. Multivariate tests were done on log-transformed relative abundance and relative biovolume data of different phytoplankton phyla.
4. Discussion
In all three types of control cosms the majority of the abundant phytoplankton taxa were identical to those found in the biocide-treated cosms. The few observed differences were not sufficient to conclude that the phytoplankton community composition reflected the applied biocide contaminations. On the other hand, a common observation throughout the three types of cosms was that the lowest taxa numbers were consistently found in the TB1000 treated cosms. Nevertheless, the differences were not statistically significant from the rest of the cosms, and this effect was not seen for the two MIX1000 microcosms that contained 1000 ng L−1 of all four biocides.
A number of water quality parameters were also measured, such as available nutrients, chlorophyll-
a, dissolved oxygen, conductivity, and pH for all the cosms, to see whether there were any significant differences among the biocide-treated samples and controls (
Supplementary Material, Tables S1, S3, and S5). No significant differences were found, except for the water phase microcosm experiment where total phosphorus concentrations in control samples were significantly lower than in those treated by biocides CD, DR, IRG, and MIX. Such a result suggests possible slower utilization of this nutrient by phytoplankton communities in the samples affected by biocides. Nevertheless, this was not observed in the sediment microcosm or mesocosm experiments. In order to draw firm conclusions about possible combined biocide contamination and different water quality parameter induced changes in phytoplankton communities, this could be explicitly studied in future works.
Different observations have been reported by a number of studies investigating phytoplankton responses to pesticide contamination. For instance, reference [
18] in a study of Lake Geneva correlated the monitored concentrations of 14 herbicides with phytoplankton species. The study did not show direct herbicide toxicity to phytoplankton, but indicated that different species have different susceptibility towards certain compounds. For instance, hazardous concentrations of TB and DR for 5% of species were found to be 30 and 50 ng L
−1, respectively. Reference [
44] tested the effects of different concentrations of IRG on single phytoplankton species in indoor nanocosms. The study showed that the effect of IRG differed greatly depending on the species. A similar conclusion has been reached by [
45], who investigated the sensitivity of different algal species to 12 pesticides. For instance, EC50 concentrations for
Asterionella formosa,
Navicula accomoda,
Scenedesmus acutus, and
Chlorella vulgaris after a 96 h experiment were found to be >253, 0.5, 5.1, and 1.5 µg L
−1, respectively.
Reference [
46] carried out an outdoor mesocosm experiment where constant exposure of atrazine (70 µg L
−1), isoproturon (14 µg L
−1), and diuron (5 µg L
−1) on phytoplankton communities was tested. After a 5 day experiment, no differences between biocide-treated and control mesocosms in terms of species composition was observed. Herbicide influence on the species diversity was seen on day 12, only due to a few sensitive species, however, while diversity in most mesocosms remained the same. Reference [
15] investigated natural plankton communities in tropical freshwater microcosms, and for tested diuron concentrations of 2.2 and 11 µg L
−1 phytoplankton taxonomic diversity was found to be unaffected. However, the phytoplankton abundance and biovolume had decreased.
In the present study, the abundance and biovolume of the phytoplankton varied greatly among the three studied cosm types. The water phase microcosms exhibited the lowest variability among biocide treatments, while several of the sediment microcosms and in situ mesocosms peaked out from the datasets with respect to the organism counts. These differences were mainly due to increased numbers of single-celled
Chroococcales, Chlorella, and
Monoraphidium. The conducted statistical tests did not show any significant differences among the biocide treatments. Despite that, visually it could be seen that phytoplankton numbers and biovolumes were somewhat lower in biocide-treated cosms compared to the control ones. In a similar study, reference [
47] studied the effect of a somewhat higher diuron concentration, 0.01 mg L
−1, on the phytoplankton ecology of a catfish pond. The authors found similar phytoplankton biomass in the diuron treated ponds and the control ponds. Yet, the biomass of filamentous blue-green algae was somewhat replaced by diatoms, indicating possible biocide pollution induced response/changes in distinct phytoplankton taxonomic groups leading to changes in dominance patterns.
In all three types of cosms of the present investigation, the response of phytoplankton phyla to the added biocide concentrations varied highly and inconsistently. One common observed tendency was though that
Chlorophyta total numbers and biovolumes increased with an increase in IRG concentration. This suggests a possible higher
Chlorophyta tolerance to the biocide. A similar observation was made by [
46], who in their herbicide affected outdoor mesocosm found that the phytoplankton communities were dominated by
Chrysophyceae,
Chlorophyceae, and
Cyanophyceae. Additionally, reference [
16] carried out an indoor pond mesocosm study, where effects of IRG at concentrations ranging from 0.04–5 µg L
−1 on phytoplankton, periphyton, and ecosystem function were tested. In that study, the biovolumes of diatom communities decreased, while green and blue-green algae increased in the more contaminated ponds.
Despite the few observations, addressing the probable stormwater phytoplankton community response to biocide contamination, the statistical analysis did not provide any clear evidence to draw firm conclusions. It is more likely that any observed differences among samples were driven by factors other than biocides, such as, nutrient limitation or the presence of zooplankton which could have regulated the abundance of certain taxa, inducing species competition for the resources and survival [
48]. Moreover, the phytoplankton communities of the studied pond are subject to considerable biocide contamination throughout the year, including terbutryn, diuron, carbendazim, and irgarol, which were investigated in the present study [
5]. As a consequence, phytoplankton might have developed a tolerance to biocide contamination and thus did not show any apparent response to the applied compounds and their concentrations. Pollution induced community tolerance is well reported in the mesocosm study by [
17], where phytoplankton sensitivity to atrazine, diuron, and isoproturon was tested. Phytoplankton communities which previously experienced exposure to these compounds were more tolerant to their contamination compared to the tested controls. A similar conclusion was drawn by [
45], who reported that phytoplankton communities which were previously subject to IRG contamination were more tolerant to IRG.
5. Conclusions
We examined the responses of natural stormwater phytoplankton communities to biocide contamination in laboratory microcosm and outdoor mesocosms. The selected biocides, namely, carbendazim, terbutryn, diuron, irgarol, and their mixture were applied at concentrations from 10 to 1000 ng L−1 of each biocide. At the ends of the tests, the phytoplankton were analyzed with respect to taxonomic diversity, abundance, and biovolume.
No apparent differences among the biocide treatment groups were observed in any of the cosm experiments at the investigated taxonomic level. The conducted statistical tests and multivariate analysis did not show any significant differences among phytoplankton communities, after being exposed to different biocide contamination. Nevertheless, a few consistent tendencies throughout the three cosm setups were observed, such as a decrease in taxa numbers where the highest terbutryn concentration was applied, and an increase in Chlorophyta abundance and biovolume with an increase in the applied IRG concentration.
One of the possible explanations for the absence of an evident phytoplankton community response to the applied biocides at the tested concentrations could be that those are probably below the threshold which causes significant toxic effects on the phytoplankton taxa. It is likely that other factors, such as nutrient limitation and the presence of zooplankton, are as much, or even more, responsible for the phytoplankton community behavior compared to the examined biocides and their concentrations.
On the other hand, the investigated stormwater pond receives inputs of biocides from the surrounding residential catchment throughout the year, including terbutryn, diuron, carbendazim, and irgarol, which were used in the cosm experiments of this study. Thus, the possibility that previous phytoplankton exposure to biocide contamination might have induced community tolerance towards them should not be neglected and could be further investigated in the future studies.