1. Introduction
Due to their simple structure and low manufacturing cost, induction motors are widely used in industrial and social applications in fans, pumps, belts, compressors, electric vehicles, etc. The complex operating conditions of these motors can easily lead to various faults in them. Inter-turn fault (ITF) is the most common type of stator fault in AC motors, accounting for about 28–36% of total faults [
1]. The overheating caused by the fault will accelerate the aging of the insulation and further deepen the degree of the fault [
2].
The thermal field of different motors with ITF has been studied [
3,
4,
5,
6,
7,
8,
9]. The variations in magnetic field and loss after the ITF in a permanent magnet synchronous motor (PMSM) are analyzed in [
3]. The distribution of the motor thermal field with different degrees of fault is given by a two-dimensional (2D) finite-element (FE) simulation, and the housing temperature in the normal condition is measured by an infrared imager. In [
4], the faulty thermal field of an induction motor, considering different contact-resistance conditions, is simulated by a 2D lumped parameter (LP) model and an FE model. On this basis, a 2D thermal field distribution of an induction motor with ITF under the voltage imbalance is considered [
5], and similar results are obtained. However, due to the difference between the actual structure of the motor and the axial heat dissipation conditions, the 2D simulation results reported in [
3,
4,
5] cannot reflect the accurate faulty thermal field distribution, and the above research lacks adequate experimental verification.
The rotor thermal field of a synchronous generator under rotor static eccentricity fault, ITF, and the combined fault are studied in [
6]. The changes in rotor loss and rotor three-dimensional (3D) magnetic field before and after the fault are given. The rotor thermal distribution in each case is obtained through 3D electromagnetic–thermal coupled simulation, and the results are verified by rotor temperature measurement. A similar coupled analysis method was also adopted in [
7]. The faulty thermal distribution of a permanent magnet-assisted synchronous reluctance motor is presented, considering the influence of changes in temperature and working condition on motor losses, and the correctness is verified experimentally. In addition, the research on the thermal field of the motor with ITF using the 3D LP model and the FE model also achieved good results [
8,
9].
The thermal stress of the rotor changes as the temperature of the rotor varies. For the rotor structure design of high-speed motors [
10] and the optimal design of motors with specific rotor structures [
11], thermal stress analysis has proven to be an efficient research method. In terms of the research on the thermal rotor stress caused by a fault [
12] focuses on the thermal stress of a hydro generator after a rotor excitation winding fault. The rotor thermal strain and stress variations are obtained by considering the different fault turns and faulty locations. In [
13], the influence of a broken bar fault on the distribution of the rotor thermal stress is analyzed, and the reason for the broken bar fault of the induction motor is presented by evaluating the maximum stress area of the rotor squirrel cage. The temperature and stress variations in the rotor squirrel cage are analyzed during the breakage development process [
14]. Furthermore, the calculated stress values of each transient operation are compared with the physical failure model of the rotor to provide a fatigue analysis and lifespan evaluation of the rotor.
In general, considering the difference in heat dissipation conditions in axial and circumferential directions of the totally enclosed fan-cooled (TEFC) motor studied in this paper, the space and time distribution of the motor thermal field after the fault and the internal transient temperature rise (TR) characteristics need to be studied. In addition, due to the particularity of the squirrel cage structure, it is necessary to evaluate the influence of faults on the rotor from the perspective of thermal stress.
In this paper, the 3D transient thermal field-rotor thermal stress field simulation and the TR measurement of the embedded thermistor are used to study the influence of ITF on the thermal characteristics of the motor. The comprehensive analysis of the faulty thermal field and the thermal stress field distribution reveal the faulty thermal characteristics of the motor, which can be used as a reference for ITF research.
The advantages of this research compared with existing literature research results can be summarized as follows: (1) The adopted 3D transient simulation can reflect the transient characteristics of faults and is closer to the practice than 2D and steady-state simulation. (2) Considering the structure of the TEFC motor, both the transient and steady-state temperature characteristics of the faulty motor are analyzed, and a fault feature is proposed using the winding temperature characteristics at different moments. (3) The rotor thermal stress analysis is introduced for the first time in studying the stator ITF in induction motors, expanding the research direction and evaluating the possibility of other faults caused by ITF.
3. Experimental Platform
In the research in the motor ITF thermal field, it is necessary to measure the TR at key parts of the motor. During the rewinding process, temperature-measuring elements are embedded inside the motor in the middle of the axial direction. The positions of each temperature-measuring point (TMP) are shown in
Figure 3 (S1–S24 are the numbers of stator slots).
TMP-A is located in the middle of the faulty slot winding; TMP-B is located in the middle of the non-faulty slot winding in the faulty phase; TMP-C and -D are, respectively, located in the middle of the non-faulty phase winding on the side and opposite side of the junction box; TMP-E and -F are located at the bottom of stator core slot at the same position of TMP-C and -D; TMP-G and -H are located in the air-gap on the side and opposite side of the junction box, and these two detectors are placed in the stator slot wedge at the air-gap side during the embedding process.
The thermal field variation of the TEFC motor caused by ITF remains to be studied. Thus, this paper does not consider the influence of different fault degrees and carries out the TR experiment of normal and faulty motors under a single fault degree. The TR experimental platform of the normal and 45-turn faulty motor under rated load conditions is shown in
Figure 4. The voltage regulator and magnetic brake are used to maintain the stability of the supply and load. The power analyzer (HIOKI 3196, Sampling rate: 200 kS/s, 2 MS/s; Accuracy: ±0.2% rdg ± 0.1% f.s. for voltage, ±0.3% rdg ± 0.01% f.s. for current) is equipped with voltage (HIOKI 9438, Input impedance: 4 M
; Maximum voltage: 600 Vrms CAT III ), and current detectors (HIOKI 9661, Maximum current: 500 Arms; Frequency range: 40 Hz–5 kHz) to monitor the electrical signals. The real-time temperature measurement for each TMP is conducted through electronic thermometers (TM902C, Resolution: 0.1 °C; Accuracy: ±0.75 °C; Range: −50–750 °C) with K-type detectors (TP-01, Accuracy: ±0.5 °C; Range: −50–400 °C, Thermal response time: 1 s). In order to ensure the safety of the prototype and experimental equipment, two short-circuit (SC) turns are connected through a contact resistance to limit the excessive SC current.
4. Heat Source Analysis
The heat source is the loss of each motor part during operation, and the total loss of the motor consists of winding copper loss, core loss, rotor aluminum loss, and mechanical and stray loss.
where
is the total loss;
is winding copper loss;
is core loss;
is rotor aluminum loss; and
is mechanical and stray loss.
Copper loss and stray loss are calculated through experimental values and empirical formulas. The electromagnetic simulation calculates core loss and rotor aluminum loss, and specific calculation methods can be found in [
17]. For a normal three-phase winding motor, the resistance and current of each phase are equal, and the copper loss can be calculated by
(
is the effective value of the phase current and
R is the value of phase resistance). The equivalent circuit topology of the motor is changed by ITF, as shown in
Figure 5, and an SC current is appended in addition to the original equal three-phase current. In the case of the fault, the copper loss of the motor can be calculated according to (
4).
Table 4 lists the copper loss values under normal and 45-turn fault conditions at 75 °C as a reference. It can be seen that the total copper loss of the motor increases significantly and that the copper loss of each phase winding varies greatly after the fault.
where
,
, and
are the effective values of each phase current;
is the effective value of SC current; and
is the resistance of the faulty coil.
Figure 6 is the distribution of the core loss of the motor before and after the fault, and the location of the faulty slot has an obvious influence on the loss space distribution. Due to the effect of the reverse pulsed magnetic field generated by the SC current, one side of the faulty slot will be magnetized, and the other one will be demagnetized [
19]. As indicated by the marks in the figure, the core loss of the teeth on both sides of the faulty slot is quite different, which further increases the non-uniformity of the distribution of core loss after the fault.
Since the core loss of the rotor is small and is considered a constant, these two values will not be discussed here. The calculated loss values of each part of the motor are converted into loss densities, which are loaded as the heat sources to the corresponding position of the thermal field model. Thus, the thermal field distribution before and after the fault can be obtained by simulation.
5. Thermal Field Analysis
Three-dimensional thermal field simulation and TR experiments are carried out for normal and faulty motors under rated load conditions. The temperature distribution law of the motor before and after the fault and the influence on the spatial and temporal thermal characteristics can be obtained.
5.1. Thermal Field Distribution before and after Fault
Figure 7 shows the simulated and measured temperature curves of the two test points (TMP-A and -F) of normal and faulty motors. It can be seen that the trend and temperature value of the simulation curves are similar to the measured ones, indicating that the accuracy of modeling and simulation is high. It should be noted that during the rated load fault test, the measured TR of the faulty slot winding reached 112.8 K (the test had been operating for 45 min), exceeding the maximum TR limit of insulation class F. In order to ensure the safety of the equipment, the test is stopped immediately. Unless otherwise specified, the steady-state temperatures of the normal and faulty motor are the ones at 90 min and 45 min, respectively.
The steady-state temperature and TR values before and after the fault of each TMP of the motor are listed in
Table 5, and the TR of each TMP of the motor is quite different. In the normal motor, due to the poor heat-dissipation conditions at the junction box position, the TR at TMP-C is higher than that at TMP-A, -B, and -D of other windings. The TRs of TMP-E and -G at the slot bottom and the air-gap of the junction box are higher than those of TMP-F and -H on the opposite side. After the fault, the temperature of all TMPs increases noticeably, and the maximum value occurs in the faulty slot winding (TMP-A). The temperature-distribution law of other measuring points related to the position of the junction box is the same as that of the normal motor.
Figure 8 is the temperature distribution of the whole motor, stator core, and rotor before and after the fault. The comparison between
Figure 8a,d shows that the hotspot of the normal motor is located in the rotor, and the temperature of the circumferential sections is approximately evenly distributed. The hotspot after the fault is located in the faulty winding, and the axial and circumferential distribution of housing temperature is no longer uniform, which shows that the housing temperature on the side close to the faulty slot is higher than that in other positions.
The temperature of the stator core and rotor increase after the fault, but the overall distribution law is consistent with the normal motor. Due to the different heat-dissipation conditions, the temperature of the stator core at the axial load side is higher than that at the fan side, and the temperature at the circumferential junction box side is higher than that at other positions. As for the rotor, there is a slight temperature difference in the axial direction, while the difference in the radial direction is large. The temperature on the load side is higher than on the fan side, and the hotspot is at the bar near the middle of the rotor. After the fault, the rotor temperature increases significantly, with an increase of 15.0%, which leads to the rise in thermal stress in the key position of the rotor, thus increasing the risk of rotor fault.
In general, the temperature of the housing, stator core, and rotor before and after the fault does not show new temperature distribution characteristics except for an obvious increase. Therefore, for the change in thermal field caused by ITF, one should focus on the temperature variation of winding.
Figure 9 shows the temperature distribution of winding in the steady state before and after the fault. Under the normal condition, the hotspot appears at the junction box side, and the overall winding temperature difference is only 4.4 °C. However, the hotspot is located in the faulty slot after the fault, and the overall temperature difference in the winding reaches 38.3 °C. Furthermore, the average temperature of each phase winding is also quite different (131.4 °C in the faulty slot of the A-phase, 110.1 °C in the non-faulty slot of A-phase, 99.45 °C in the B-phase, 95.94 °C in the C-phase).
5.2. Thermal Characteristics Caused by Fault
The TR of the motor is obvious in the early stage of operation after the fault, as shown in
Figure 7b. In order to study the impact of the fault on the TR characteristics of the motor, the measurement data of the first nine minutes under normal and faulty conditions at TMP-A are drawn in
Figure 10. The temperature of this position changes drastically after the fault, and the TR in the first nine minutes is more than twice that of the normal motor. Taking the time to reach the normal TR of the motor as the measurement standard, the TR time at this point after the fault is 88.9% shorter than the normal time.
ITF will cause great changes in the heat generation rate of each part of the motor before and after the fault and then lead to a time change in TR at the same TMP, as well as overall temperature space distribution variation caused by the related position to the faulty slot. The measured TR and TR time of the first nine minutes before and after the fault of each TMP are plotted in
Figure 11. The TR time of each TMP is defined as the time to reach the normal TR of the motor, and the shortening of the TR time of each point is marked in the figure. The data in the figure show that the TR of the fault phase winding is large and the TR rate is fast (TMP-A and -B), especially the faulty slot winding, while there is little difference between the TR and TR rate of TMPs at other positions. Since the TMPs are located in different parts of the motor, the difference in temperature distribution and TR time of each TMP further explains the space and time characteristics of motor temperature caused by the fault.
According to the analysis results in the previous section, the temperature characteristics of the motor housing, stator core, and rotor are not obvious after the fault; on the other hand, the part with the most drastic temperature change is the stator winding.
Figure 12 shows the temperature distribution of stator winding at three different moments. The positions of each slot, phase belt, and the faulty slot are marked in the figure. It can be seen that the temperature distribution of normal motor windings is evenly distributed in the initial stage, middle stage, and steady state of operation, and the temperature difference between windings in different slots is small. The distribution of winding temperature after the fault is complex. The temperature of non-faulty phase winding shown in
Figure 12a is almost the same as that of the normal motor in the initial stage of faulty operation, while the temperature of the faulty phase winding increases significantly and the temperature of the faulty slot winding is the highest. From the middle stage of faulty operation to the final moment, the winding temperature of the faulty phase continues to rise, the temperature distribution remains unchanged, and the temperature of non-faulty winding also gradually increases, which is significantly higher than the temperature of the normal motor.
In order to measure the temperature distribution of stator winding before and after fault, variance (
) is used to evaluate the dispersion of winding temperature distribution caused by the fault.
in
Table 6 is the temperature variance of all 24 slots. Under normal conditions, the
value is small, indicating that normal motor-winding temperature is evenly distributed, while the dispersion degree of overall winding temperature is significantly improved after the fault. The great difference in
before and after the fault is accompanied by three moments of motor operation, indicating that this feature can be used as a thermal feature of ITF for fault diagnosis. However, it is impossible to monitor the winding temperature of all slots in practice; thus, it is measured by extracting one slot winding per phase.
is the data that do not contain the faulty slot winding (S4, S8, S12), and
is the data that contain the faulty slot winding (S3, S7, S11). It can be seen that the three data are extremely small under normal conditions. Even if
does not have the faulty slot winding, the temperature also has a large deviation in the statistical data value after the fault, and this deviation is further enlarged for
. It should be noted that the values in
Table 6 only provide a reference for fault diagnosis. The specific winding monitoring mode and the definition of the fault feature need to study the changes caused by different fault degrees, which will be carried out in future research work.
7. Conclusions
In this paper, the thermal characteristics of an induction motor under a rated load before and after the stator ITF are analyzed using a 3D transient thermal field, stress-field simulation, and TR experiment, and the conclusions are as follows:
- (1)
The original temperature distribution law of the motor is broken after ITF, and the hotspot of the motor is transferred from the rotor to the faulty slot winding. The TR of each part of the motor is higher than that under normal conditions, and the difference in space and time characteristics of temperature distribution is further increased due to the different TR values and TR rates of each part.
- (2)
The significant thermal characteristic of ITF is the difference in winding temperature distribution. Taking the TR of normal winding in the first nine minutes as the standard, the TR value and TR time of winding in the faulty slot are 2.2 times and 11.1%, respectively, of those of the normal motor. The statistical variance data of winding temperature show that the fault causes the discrete distribution of winding temperature, and the variance value can provide a reference for fault diagnosis.
- (3)
The rotor thermal stress analysis is introduced for the first time in studying the stator ITF in induction motors. The maximum thermal stress of the squirrel cage rotor occurs at the bottom of the bar near the joint of the end-ring. After the fault, due to the increase in rotor temperature, the thermal stress value at this place further increases (20.7% higher than that under normal conditions), which intensifies the risk of broken bar fault.
Moreover, further work is in progress to study the difference in TR characteristics under various fault degrees, assess the impact of fault on the remaining life of insulation, and propose a fault diagnosis method from the perspective of thermal characteristics.