Next Article in Journal
Sensitivity Analysis of Bogie Wheelbase and Axle Load for Low-Floor Freight Wagons, Based on Wheel Wear
Previous Article in Journal
Computational Fluid Dynamics-Based Optimisation of High-Speed and High-Performance Bearingless Cross-Flow Fan Designs
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Simulation Study on Arc Temperature of Urban Rail DC Pantograph-Catenary and Arc Ablation of Contact Line

School of Automation & Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
*
Author to whom correspondence should be addressed.
Machines 2024, 12(8), 514; https://doi.org/10.3390/machines12080514
Submission received: 19 June 2024 / Revised: 17 July 2024 / Accepted: 26 July 2024 / Published: 29 July 2024
(This article belongs to the Section Electrical Machines and Drives)

Abstract

The high temperature generated by the DC pantograph-catenary arc of urban rail systems will aggravate the wear of the pantograph-catenary system. When the ablation intensifies, it will lead to disconnection accidents on the contact line. In this paper, through the establishment of a pantograph-catenary arc model and contact line arc ablation model, considering the flow of the molten pool, it is reported that the temperature distribution of the pantograph-catenary arc is axisymmetric. With the increase in the arcing time, the maximum temperature of the arc increases. The heat flux density of the arc injection contact line presents a Gaussian distribution and is positively correlated with the arcing time. The high-temperature area of the contact line and the distribution of the molten pool show an approximate arc shape. The velocity of the molten pool shows a symmetrical distribution about the center of the electrode. The area, depth, and radius of the molten pool of the contact line increase with an increase in the arcing time, and the radius of the molten pool is always greater than the depth of the molten pool. The work presented in this paper is helpful to further our understanding of the basic physical process of pantograph-catenary arc ablation of contact lines.
Keywords: urban rail transit; pantograph-catenary arcing; temperature distribution; contact line; molten pool urban rail transit; pantograph-catenary arcing; temperature distribution; contact line; molten pool

Share and Cite

MDPI and ACS Style

Yu, X.; Wang, Z.; Song, M.; Song, L.; Yang, J.; Su, Y. Simulation Study on Arc Temperature of Urban Rail DC Pantograph-Catenary and Arc Ablation of Contact Line. Machines 2024, 12, 514. https://doi.org/10.3390/machines12080514

AMA Style

Yu X, Wang Z, Song M, Song L, Yang J, Su Y. Simulation Study on Arc Temperature of Urban Rail DC Pantograph-Catenary and Arc Ablation of Contact Line. Machines. 2024; 12(8):514. https://doi.org/10.3390/machines12080514

Chicago/Turabian Style

Yu, Xiaoying, Ze Wang, Mengjie Song, Liying Song, Junrui Yang, and Yang Su. 2024. "Simulation Study on Arc Temperature of Urban Rail DC Pantograph-Catenary and Arc Ablation of Contact Line" Machines 12, no. 8: 514. https://doi.org/10.3390/machines12080514

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop