Next Article in Journal
Parametric Automated Design and Virtual Simulation of Building Machine Using BIM
Next Article in Special Issue
Influences of the Decomposition Atmosphere and Heating Rate on the Pyrolysis Behaviors of Resin Sand
Previous Article in Journal
A Comparative Analysis of Optimization Algorithms for Finite Element Model Updating on Numerical and Experimental Benchmarks
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Bond Strength of Reinforcing Steel Bars in Self-Consolidating Concrete

Durham School of Architectural Engineering and Construction, College of Engineering, University of Nebraska—Lincoln, 1110 South 67th Street, Omaha, NE 68182-0816, USA
*
Author to whom correspondence should be addressed.
Buildings 2023, 13(12), 3009; https://doi.org/10.3390/buildings13123009
Submission received: 16 October 2023 / Revised: 21 November 2023 / Accepted: 25 November 2023 / Published: 1 December 2023

Abstract

This paper presents an experimental investigation of the bond strength of reinforcing steel bars in tension in self-consolidating concrete (SCC). The effects of the reinforcing bar’s location, orientation, size, and coating on the bond strength with SCC were studied and compared to those with conventionally vibrated concrete (CVC). Several SCC mixtures were developed to cover a wide range of applications/components and material types. The fresh properties of the SCC mixtures were determined to evaluate their filling ability, passing ability and stability. Two hundred and thirty-four pull-out tests of rebars embedded in cubes, wall panels and slabs were conducted. Almost half of the tests were conducted to evaluate the bond with SCC and the other half with CVC. Load–slippage relationships were measured for each test. Pull-out test results were analyzed, and the bond strength was reported in two values: critical strength, which corresponds to slippage of 0.01 in. *0.25 mm); and ultimate strength, which corresponds to the maximum load. The critical strength of SCC and CVC were compared against the ACI 318-19 provisions and comparisons between the ultimate strength of SCC and CVC were conducted. The comparisons indicated that SCC has lower bond strength with vertical rebars than CVC, and a 1.3 development length modification factor is recommended. A similar conclusion applies to epoxy-coated and large diameter rebars. Also, SCC with high slump flow has shown a less top-bar effect than that of CVC.
Keywords: bond strength; self-consolidating concrete; top-bar effect; orientation of the rebar; epoxy-coated rebar bond strength; self-consolidating concrete; top-bar effect; orientation of the rebar; epoxy-coated rebar

Share and Cite

MDPI and ACS Style

Asaad, M.; Morcous, G. Bond Strength of Reinforcing Steel Bars in Self-Consolidating Concrete. Buildings 2023, 13, 3009. https://doi.org/10.3390/buildings13123009

AMA Style

Asaad M, Morcous G. Bond Strength of Reinforcing Steel Bars in Self-Consolidating Concrete. Buildings. 2023; 13(12):3009. https://doi.org/10.3390/buildings13123009

Chicago/Turabian Style

Asaad, Micheal, and George Morcous. 2023. "Bond Strength of Reinforcing Steel Bars in Self-Consolidating Concrete" Buildings 13, no. 12: 3009. https://doi.org/10.3390/buildings13123009

APA Style

Asaad, M., & Morcous, G. (2023). Bond Strength of Reinforcing Steel Bars in Self-Consolidating Concrete. Buildings, 13(12), 3009. https://doi.org/10.3390/buildings13123009

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop