Next Article in Journal
Trilateral Evolutionary Game Strategy for the Design Optimization of Engineering General Contracting Projects in the Chinese Context
Previous Article in Journal
Comparative Study on the Heat Transfer via Unheated Spaces Based on Correction Factor
Previous Article in Special Issue
District Heating Deployment and Energy-Saving Measures to Decarbonise the Building Stock in 100% Renewable Energy Systems
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Hydrogen Blending in Natural Gas Grid: Energy, Environmental, and Economic Implications in the Residential Sector

by
Domiziana Vespasiano
,
Antonio Sgaramella
,
Gianluigi Lo Basso
,
Livio de Santoli
and
Lorenzo Mario Pastore
*
Department of Astronautical, Electrical and Energy Engineering, Sapienza University of Rome, 00184 Roma, Italy
*
Author to whom correspondence should be addressed.
Buildings 2024, 14(8), 2284; https://doi.org/10.3390/buildings14082284
Submission received: 9 June 2024 / Revised: 17 July 2024 / Accepted: 20 July 2024 / Published: 24 July 2024
(This article belongs to the Special Issue Sustainable and Smart Energy Systems in the Built Environment)

Abstract

:
The forthcoming implementation of national policies towards hydrogen blending into the natural gas grid will affect the technical and economic parameters that must be taken into account in the design of building heating systems. This study evaluates the implications of using hydrogen-enriched natural gas (H2NG) blends in condensing boilers and Gas Adsorption Heat Pumps (GAHPs) in a residential building in Rome, Italy. The analysis considers several parameters, including non-renewable primary energy consumption, CO2 emissions, Levelized Cost of Heat (LCOH), and Carbon Abatement Cost (CAC). The results show that a 30% hydrogen blend achieves a primary energy consumption reduction of 12.05% and 11.19% in boilers and GAHPs, respectively. The presence of hydrogen in the mixture exerts a more pronounced influence on the reduction in fossil primary energy and CO2 emissions in condensing boilers, as it enhances combustion efficiency. The GAHP system turns out to be more cost-effective due to its higher efficiency. At current hydrogen costs, the LCOH of both technologies increases as the volume fraction of hydrogen increases. The forthcoming cost reduction in hydrogen will reduce the LCOH and the decarbonization cost for both technologies. At low hydrogen prices, the CAC for boilers is lower than for GAHPs; therefore, replacing boilers with other gas technologies rather than electric heat pumps increases the risk of creating stranded assets. In conclusion, blending hydrogen into the gas grid can be a useful policy to reduce emissions from the overall natural gas consumption during the process of end-use electrification, while stimulating the development of a hydrogen economy.

1. Introduction

As the phenomenon of global warming and its consequences continue to develop, the necessity to reduce greenhouse gas (GHG) emissions is becoming increasingly apparent. Therefore, the implementation of energy systems that integrate renewable energy sources is of paramount importance for the immediate decarbonization of the energy sector. This results in a significant enhancement of the flexibility of energy systems [1]. Electric batteries can play an important role in renewable energy integration. Nevertheless, this technology is not sufficient to address the issue, and more effective storage devices are therefore being sought [2]. Hence, the integration of diverse strategies and the conversion of energy carriers that enhance storage capacities represent suitable solutions for guaranteeing the flexibility of the energy system [3]. In this context, the utilization of hydrogen becomes a crucial factor. Indeed, numerous studies have identified hydrogen as a key vector for facilitating the integration of renewable energy sources at high percentages [4,5]. The European Hydrogen Strategy has the objective of making hydrogen a substantial part of the European energy system. The ambitious targets of the strategy set forth a goal of achieving a minimum production of 10 million tonnes of hydrogen from renewable sources by 2030 along with the installation of 40 GW of electrolyzers. Furthermore, the national gas grid should be employed as a means of distributing hydrogen over long distances, thereby contributing to the development of adequate storage facilities [6]. In order to achieve the 2050 climate neutrality targets, it is necessary to reduce emissions from the hard-to-abate sectors, which are characterized by high energy intensity and a lack of viable electrification solutions [7]. Currently, the chemical and petroleum refining sectors utilize hydrogen as a raw material in the production of basic chemicals such as ammonia and methanol, as well as in a number of refining processes [8]. Accordingly, by 2050, hydrogen carriers should represent at least 13% of the European energy mix in order to achieve the set climate neutrality targets [9]. It is of significant importance to emphasize that the European Hydrogen Strategy has been designed with the intention of facilitating the long-term deployment of renewable hydrogen and the transition to low-carbon hydrogen. Indeed, despite currently accounting for the majority of hydrogen produced [10], hydrogen produced by steam reforming remains excluded from the planning. The objective is therefore to gradually increase the proportion of green hydrogen in industry [11]. A further hard-to-abate sector is transport, in particular heavy [12], public [13] and maritime transport [14]. Nevertheless, in the absence of refueling stations across the country, the production of synthetic natural gas (SNG) [15] or other alternative fuels [16] could be considered potential applications for immediate decarbonization of the transport segment.
The implementation of a hydrogen economy may encounter initial obstacles related to the lack of dedicated storage and distribution infrastructures [17]. In this context, a potential interim solution could be the injection of hydrogen into natural gas (NG) distribution networks [18,19]. It is indeed feasible to employ limited hydrogen volumetric fractions (fH2,vol) in hydrogen-enriched natural gas (H2NG) mixtures in such a way that this blend can be used in end-user devices without necessitating significant operational changes [20]. According to Jones et al. [21] and Schiro et al. [22], the threshold limit for safely running domestic end-user devices without any modifications on commercial versions is equal to 30% vol. of hydrogen content. Based on these studies, the limit value for the volumetric fraction of hydrogen used in the present study was selected. It has been widely demonstrated that the utilization of H2NG mixtures within end-user devices can result in technical and environmental benefits [23]. In fact, the incorporation of hydrogen fractions within the natural gas (NG) network could potentially reduce GHG emissions from heating systems while simultaneously enhancing combustion efficiency. Indeed, hydrogen has a high flame velocity and a wide flammability range, which would permit more complete combustion in a mixture, thereby reducing pollutants such as CO and nitrogen oxides (NOx). Furthermore, its higher energy density per unit mass, if compared to natural gas (NG), enables a reduction in the volume of fuel required when used in a blend.
Nevertheless, the integration of hydrogen still presents unresolved problems that are intrinsically linked to the very characteristics of H2. In addition to the lack of adequate facilities for transport and storage, hydrogen is characterized by high flammability, which could create safety problems, especially in residential applications [24]. Furthermore, hydrogen is characterized by high energy losses related to compression and liquefaction processes, with losses of 10% and 40%, respectively [25]. From a mechanical standpoint, it is also essential to consider the potential for hydrogen embrittlement, which could impact the yield stress and strength of the materials. Consequently, the current design process of transmission networks can only be considered valid for low volumetric fractions of hydrogen in the mixture, due to the low ignition energy of hydrogen, which could cause accidents [26]. Indeed, the thermophysical properties of the mixture are significantly influenced by the proportion of hydrogen utilized. The utilization of H2NG blends would facilitate a more extensive diffusion of the hydrogen carrier, while also representing an economically viable means of storage and transport [27]. The utilization of these mixtures of H2NG would also result in an immediate reduction in CO2 emissions associated with end-user systems, with reductions varying depending on the device considered [28,29,30]
A number of European countries have already enacted legislation on the introduction of hydrogen into the grid. For instance, France and Spain have imposed a limit of 6% and 5% by volume, respectively. In Germany, the threshold of fH2, vol in the mixture is 10%, but only under specific conditions and in designated infrastructure sections. In many European countries, the maximum permitted blending ratio is 4% [31]. Other countries, such as Italy, have not yet enacted legislation to incorporate H2NG blending into their energy systems. However, their strategy encourages the implementation of such a solution in the next decade [32]. In fact, the employment of this vector would facilitate the achievement of decarbonization objectives in the building heating sector, which are challenging to attain through the implementation of efficiency enhancements or the electrification of end-user systems in isolation [33]. Moreover, the building sector is frequently constrained by spatial limitations and architectural constraints that preclude the installation of large-scale renewable energy systems, thereby complicating the task of reducing emissions [34]. The utilization of mixtures of hydrogen and natural gas in the building sector will result in increased primary fossil energy savings through the deployment of highly efficient gas systems.
This work aims to evaluate the H2NG effects on technical, economic, and environmental parameters of two different plant configurations: condensing boilers and Gas Adsorption Heat Pumps (GAHPs). Some experimental investigations have already analyzed the effects of using H2NG mixtures on condensing boilers, while there are still few studies on GAHPs. Lamioni et al. [35] numerically simulated the use of H2NG mixtures on condensing boilers. Their study showed that the use of hydrogen causes the flame front to advance towards the burner, causing the risk of flashback, but at the same time, it prevents temperature rise due to the dilution phenomenon. The temperature reduction observed has a positive effect on the reduction in NOx emissions. In their study of a condensing boiler, Yang et al. [36] showed how the use of 100% hydrogen as a fuel leads to an increase in the efficiency of the appliance of 8.8 percentage points. It was also shown that the boiler condenser can adequately meet the heat transfer demand when using H2NG blends, demonstrating the feasibility of this energy-saving approach. Furthermore, with an 80% hydrogen content, the CO2 emission intensity could be reduced by 55.4%, demonstrating the positive environmental impact of using H2NG blends. Sforzini et al. [37] focused on developing and validating a mathematical model for a GAHP running on unconventional gaseous fuels, specifically hydrogen-enriched natural gas blends. The study revealed that from an energetic point of view, the hydrogen addition does not visibly influence the machine’s performance. This is due to the fact that the tested GAHP heat recovery architecture is not able to exploit latent heat by condensing out the exhaust gas water content.
Some works analyzed the combustion effects of blending hydrogen in gas-driven end-user systems. Other works analyzed the technical and economic aspects of feeding gas-fired heating systems in residential buildings. However, to the best of the authors’ knowledge, there is a gap in the literature regarding the broader analysis of the energy, environmental, and economic effects of implementing hydrogen blending policies in gas-based countries. The present work aims to fill this gap by investigating such aspects from the point of view of the end-users, who see variations in the quality of the gas mixture consumed, with consequent implications for primary energy, plant efficiency, emissions, and costs associated with their heat requirements.
In this scenario, the aim is to make a comparison between two different heat generation systems, one traditional and widely used, such as gas boilers, and one innovative, such as GAHPs, and to assess how the use of H2NG blends can affect several technical and environmental parameters. Different parameters were assessed at variable H2 volumetric fractions of the blend. Due to the effects of hydrogen on technical, environmental, and economic parameters, different fractions of hydrogen ranging between 0% and 30% were assessed. Finally, the economic parameters were evaluated at different hydrogen and natural gas costs, respectively, by means of two sensitivity analyses.
Similar analyses have been implemented for other H2NG end-uses, such as internal combustion engines [38,39], household appliances [40,41], industrial burners [42,43], and CHPs [44,45].

2. Materials and Methods

The purpose of this study is to evaluate the efficiency and cost-effectiveness of two heating systems applied to a building. To conduct this evaluation, a methodology was developed for assessing the energy, environmental, and economic performances of a condensing boiler and a GAHP. The proposed scenarios have been dynamically implemented in MATLAB/SIMULINK to determine the power required to fulfill the heating demand of the building. Several energy, environmental, and economic parameters related to boiler operation were then evaluated. The latter is considered the reference case when supplied with natural gas. The second system envisages the replacement of the boiler with a GAHP. Subsequently, the operation of the two systems has been evaluated by powering them with hydrogen fractions varying between 0 and 30% by volume, with a gradual increase of 10%. Next, many sensitivity analyses were conducted to ascertain how the impact of variations in the costs of the two energy vectors employed and the fraction of hydrogen replaced in the mixture affects the economic viability of the proposed interventions.

2.1. Case Study

The residential building considered as a case study is situated within a renewable energy community in Rome. Such a case study has already been analyzed and described in Ref. [46]. Four distinct housing types have been identified within the building by the study by Mancini et al. [47], whose characteristics, electrical consumptions, and heating demands are presented in Table 1. All values in Table 1 are taken from Ref. [46]. The total surface of the building was calculated as equal to 1990 m2. The study enabled the estimation of the thermal demand to be carried out, starting from the definition of average energy performance indicators for a residential complex located in Rome. The energy performance indicator for the heating phase is considered equal to 70.3 kWh/m2 yr. The hourly profiles related to the heating demand were evaluated from data obtained from the Hotmaps Project [48]. In order to determine the annual thermal energy demand of the entire building, the demands of the individual apartments, related to the m2 of each housing unit, and the number of housing units within the structure were considered. The annual heating demand was thus determined to be 139.9 MWh/yr as seen in Figure 1. Therefore, for each type of dwelling, the total heat load was determined by considering five dwelling units, while the surfaces are referred to as a single unit.

2.2. Energy, Economic, and Environmental Model for Simulation

To be able to evaluate the energy, environmental, and economic performances of the boiler and GAHP systems, several parameters were considered such as non-renewable primary energy consumption (EPnr,t), CO2 emissions, Levelized Cost of Heat (LCOH), and Carbon Abatement Cost (CAC).
In order to verify the viability of the proposed scenarios, they were dynamically implemented in the MATLAB/SIMULINK environment and simulated on an hourly basis over a full year. Initially, the fuel utilized was only natural gas (NG), followed by a transition to H2NG blends. Specifically, knowing the power required to fulfill the heating demand of the building, the thermal power related to the different mixtures can be obtained from Equations (1) and (2) for the boiler and GAHP, respectively. The quantity of NG varies according to the hydrogen fractions considered for the mixture.
P H 2 N G , b o i l e r t = P t h , D ( t ) η b o i l e r ( t )
P H 2 N G , G A H P t = P t h , D ( t ) η G A H P ( t )
It should be noted that when a change is made to the composition of the mixture, the power supplied to the end-user remains constant. Consequently, the power supplied is dependent upon the efficiency of the system under consideration. Once the supply of thermal power was established, it was therefore possible to determine the amount of energy produced as the mixture under consideration varied, using the following equation:
E H 2 N G = t P H 2 N G
The fraction of energy derived from hydrogen can be quantified by multiplying the energy content of the mixture by the hydrogen fraction applied.
E f H 2 = E H 2 N G · f H 2 , v o l · L H V H 2 , v o l L H V H 2 N G , v o l
The efficiency of the GAHP system was considered constant and equal to 1.4, while the efficiency of the boiler was considered variable as the fraction of H2 varied. As Ref. [49] points out, the indirect method, which is also certified by UNI 10389 [50] in Italy, allows for the assessment of combustion efficiency from sensible heat losses using temperature probes and a gas analyzer. The combustion efficiency for a condensing boiler can be determined using the following equation:
η C = 1 P l o s s , s e n s P f u e l + E F C
where Energy Fraction of Condensation (EFC) indicates the fraction of latent heat resulting from water vapor condensation relative to the energy absorbed by the boiler. It should be noted that both the water dew point temperature and the flue gas temperature at the stack can be used to calculate the mass of water, the actual latent heat recovered, and the EFC factor.
E F C = P l a t e n t P f u e l
In order to evaluate the efficiency variation due to different H2NG mixtures burned in the boiler, certain parameters were defined including the flue gas outlet temperature equal to 45 °C and an external ambient temperature of 0 °C [51]. The percentage of sensible heat loss to the stack can be determined using Equation (7).
P l o s s , s e n s P f u e l = ( K 1 20.9 O 2 + K 2 ) · Δ T
ΔT is determined by the difference in flue gas outlet temperature and the external ambient temperature. The oxygen content in the flue gas outlet was considered to be equal to 4%. The values of the K1 and K2 coefficients as the H2NG mixture varies are provided in Table 2. The EFC factor can be determined using Equation (8).
E F C = ( H V R 1 ) · η c o n d
Here, HVR is the Heating Value Ratio and is defined as the ratio between the HHV (higher heating value) and the LHV (lower heating value) of the considered mixtures. The other component in the equation is the condensation efficiency (ηcond), which is defined as the ratio between the actual condensed water mass and the maximum condensable mass. The HVR and ηcond values, obtained from Ref. [49], are based on the varying fraction of applied hydrogen, as shown in Table 2.
The values of the combustion efficiency obtained for different H2NG mixtures are shown in Table 3.
The non-renewable primary energy consumption and the CO2 emissions were calculated using factors determined by Ref. [52] as the H2NG mixture used in the two systems varied. EPnr,t for the reference year was calculated using Equation (9).
E P n r = ( E H 2 N G E f H 2 ) · f n r , N G
In this equation, fnr,NG is the factor for non-renewable primary energy related to NG. In order to consider the annual equivalent CO2 emissions of the two systems, it is necessary to establish the following relationship (10):
C O 2 , e q = ( E H 2 N G E f H 2 ) · f e , N G
In this equation, fe,NG is the factor required to calculate the emissions associated with NG.

2.2.1. Levelized Cost of Heat

The Levelized Cost of Heat is an economic parameter that assesses the costs of heat produced by a defined system and helps to compare the various technologies for process heating and power generation [53]. The LCOH was calculated as the sum of the annual costs divided by the energy supplied annually, in accordance with Ref. [54].
L C O H = P · C A P E X · c r f + C O & M + C F U E L E t h
The dimensions of the two devices were determined from the rated power (P) of the entire building, which was calculated to be 88 kW [46]. The annual costs were calculated on the basis of an initial installation cost (CAPEX) in EUR/kW for each of the two devices, with the cost varying according to the technology implemented. In order to evaluate the part of the installation costs related to each year of the useful life of the plant, a capital recovery factor (crf) was considered. This is defined from Equation (12) as the ratio of the present value of the net cash inflows to the initial investment [55].
c r f = i · ( 1 + i ) t ( 1 + i ) t 1
In Equation (12), i stands for the interest rate applied and t is the lifetime of the plant considered. The data provided by the Danish Energy Agency enabled the estimation of the percentage of costs required to operate and maintain the plants [56]. The annual fuel purchase cost was then estimated, varying according to the efficiency of the device and the mixture of hydrogen and methane considered. This cost is calculated according to the following relationship (13):
C F U E L = E t h · η · P H 2 N G , E
where Eth is the total heat demand of the whole building, η is the efficiency of the device used, and (PH2NG,E) is the calculated price for the mixture. The efficiency of the GAHP was considered to be constant, whereas for the condensing boiler, the variation in efficiency due to the use of mixtures with different hydrogen fractions inside was taken into account. The efficiency values when varying the volumetric fraction of hydrogen used are presented in Table 1. The price of the mixture was then evaluated through the following relationship (14) [57]:
P H 2 N G , E = f H 2 , v o l · P H 2 L H V H 2 , m a s s · L H V H 2 , v o l L H V H 2 N G , v o l + P N G · 1 f H 2 , v o l · L H V N G , v o l L H V H 2 N G , v o l
The relationship allows the cost per unit of energy of the mixture to be assessed. It is a function of the price of hydrogen considered in EUR/kg, the price of natural gas in EUR/MWh, the lower heating value (LHV) of natural gas in MJ/Nm3, the LHV of hydrogen in mass and volume, in MJ/kg and MJ/Nm3, respectively, and the LHV of the mixture depending on the volumetric percentage of H2 involved.

2.2.2. Carbon Abatement Cost

The Carbon Abatement Cost (CAC) is an economic parameter expressed in EUR/tonne of CO2 avoided [58]. This parameter refers to the cost associated with the implementation of measures or technologies aimed at reducing carbon dioxide emissions when compared with a reference scenario in which no such measures are taken. In simpler terms, CAC represents the cost of avoiding the emission of one ton of CO2. It is evident that the Carbon Abatement Cost (CAC) may fluctuate considerably in accordance with the technologies employed, the geographical and economic context, and specific local conditions [59]. Consequently, the utilization of this metric, as observed in this paper, is a prevalent methodology employed for the assessment of the cost-effectiveness of measures designed to reduce carbon emissions. Additionally, this approach enables an evaluation of the efficacy of these strategies in terms of climate change mitigation. Furthermore, it can be observed that this value, in addition to the LCOH described above, is also affected by the quantity of hydrogen utilized in the H2NG mixture. The Carbon Abatement Cost is thus defined as the ratio of the difference between the investment and O&M costs for the technology under consideration and the CO2 emissions avoided with the use of this technology [57], as shown in Equation (15).
C A C = C A P E X i · c r f i + C O & M , i + C f u e l , i , f H 2 ( C A P E X b o i l e r · c r f b o i l e r + C O & M , b o i l e r + C f u e l , b o i l e r , 0 % ) C O 2 ,   i ,   f H 2 C O 2 ,   b o i l e r , 0 %

2.3. Techno-Economic Assumptions

In order to determine the different parameters, some techno-economic assumptions are needed. To proceed with the calculation of EPnr and the assessment of CO2 emissions, two different factors were defined. From Ref. [52], it was possible to determine the value of the factor fnr,NG to be equal to 1.05, while the factor fe,NG was considered equal to 201.4 kgCO2/MWh. Table 4 shows the values of the lower heating value (LHV) and the density of the H2NG mixture. The LHV mass for hydrogen is defined as 120 MJ/kg and the density ρ of H2 as 0.0899 kg/Nm3, as a function of the fraction of hydrogen within the H2NG mixture. All values in Table 4 are taken from Ref. [49].
The price of the mixture was evaluated considering a natural gas price of 93 EUR/MWh [60] and an estimated hydrogen price of 5 EUR/kg [61]. In order to annualize the investment costs, it was necessary to estimate an interest rate of 3% and determine the life cycle of the devices considered. The main techno-economic assumptions related to the two systems used are shown in Table 5.

3. Results

In this section, the outcomes of the work are presented and discussed.

3.1. Environmental Effects of H2 Addition on Boiler and GAHP Systems

In order to verify the impact of H2NG on the boiler and GAHP, it is first necessary to consider the annual non-renewable primary energy consumption and the CO2 emissions for both systems.
As illustrated in Figure 2, the utilization of the GAHP results in a reduction in primary energy consumption, even when only NG is burned in the system. This reduction is attributed to the enhanced efficiency of the GAHP system. Indeed, in the NG fuel case, there is a 25.69% reduction in the EPnr,t between the boiler and GAHP, with a value of non-renewable primary energy consumed of 104.93 MWh/y. However, when the H2NG mixture is employed, a linear decrease in non-renewable primary energy consumption can be observed, reaching 124.19 MWh/y and 93.18 MWh/y for the boiler and the GAHP, respectively, with a 30% volume fraction of hydrogen in the mixture. This phenomenon can be attributed to the progressive increase in the hydrogen volumetric fraction, which consequently results in a reduction in natural gas consumption. Furthermore, it can be observed that as the hydrogen fraction increases, the reduction is marginally greater in the boiler than in the GAHP, due to enhanced boiler efficiency by increasing fH2,vol. Indeed, a reduction in EPnr,t of 12.05% and 11.19% for the boiler and GAHP, respectively, is achieved when 30% hydrogen is implemented in the mixture.
A similar trend and percentage reduction can be observed for CO2 emissions since they are directly related to the NG consumption recorded for the system. In fact, if we consider the boiler, we can observe a reduction in CO2 emissions from 27.08 to 23.82 tons per year. Similarly, for the GAHP, we can see a reduction from 20.13 to 17.87 tons per year. This reduction is achieved by increasing the hydrogen fraction within the mixture from 0% vol. to 30% vol. The GAHP is more cost-effective when fueled with natural gas (NG) due to its higher efficiency, which enables it to consume smaller quantities of fuel and consequently produce less carbon dioxide. Even when the two systems are fed the H2NG mixture with different H2 volumetric fractions, the GAHP remains a more cost-effective option, with lower CO2 emissions and a lower consumption of non-renewable primary energy. The results demonstrate that the GAHP is a technology that can reduce emissions by more than 25%. This potential can be further enhanced by implementing policies pertaining to hydrogen injection and by encouraging the decarbonization of the gas grid in the future.

3.2. Levelized Cost of Heat

The LCOH parameter is used to evaluate the cost of heat production in the different heating system configurations and hydrogen fraction scenarios. Figure 3 illustrates the variation in the cost of the H2NG mixture as the fH2,vol changes considering an NG price equal to 93 EUR/MWh. Also, two maximum and minimum values for the price of natural gas were then evaluated according to the data collected in Ref. [60] for residential consumption over the last four years, equal to 121 EUR/MWh and 63 EUR/MWh, respectively. The cost of the H2NG mixture increases as the fH2,vol increases, due to the higher cost of hydrogen compared to natural gas when considering a price of 5 EUR/kg for the purchase of hydrogen [61]. At fH2,vol of 30%, the fuel price increases by 6.88% when a price for the NG equal to 93 EUR/MWh is considered.
In Figure 4, the LCOH of the GAHP and boiler systems supplied by different H2NG blends are depicted. The LCOH of the GAHP fed by NG is equal to around 102 EUR/MWh. This cost is lower than the NG boiler due to the higher efficiency of the GAHP system, which allows a lower amount of fuel to be purchased for the same amount of energy produced. Such an efficiency increase allows offsetting of the higher investment cost. As the proportion of hydrogen in the mixture increases, the LCOH rises due to the higher cost of hydrogen compared to natural gas. A 30% hydrogen volume fraction for the GAHP results in an increase in the LCOH of 4.47% compared to the case with NG alone. In the case of the boiler, the LCOH also demonstrates an increasing trend, with an increase of 4.93% observed when an H2NG mixture with a 30% vol. H2 content is employed.

3.3. Carbon Abatement Cost

Figure 5 shows the CAC trend for the two devices as the fH2,vol varies. The change in boiler efficiency when the fH2,vol in the H2NG mixture varies affects this parameter. An increase in efficiency of 0.96% is achieved by using a 30% volumetric hydrogen fraction, resulting in a 27.7% reduction in CAC compared to the base case. The decarbonization cost has been calculated with respect to the reference scenario involving the NG boiler. The GAHP can reduce the overall cost of heat production; therefore, the CAC achieves negative values representing cost-effectiveness in its use. Furthermore, even when fH2,vol values up to 20% are considered, the CAC of the GAHP is negative. Taking into consideration a fH2,vol of 30%, the CAC is nevertheless very low. From this trend, it can be inferred that the economic advantage of the GAHP is reduced as the volumetric fraction of H2 used increases, due to the higher cost of fuel purchasing. Nevertheless, it is important to note that while the hydrogen price causes costs to rise, the increased quantity of hydrogen used in the heating process helps to reduce CO2 emissions. In contrast, different considerations must be made about the boiler, as the CAC in these scenarios is linked only to the hydrogen blending in the gas grid. Therefore, the emission reduction as well as the increase in blend price is due to the increase in fH2,vol. The current hydrogen prices are correlated with high values of CAC, approximately 220 EUR/kgCO2,avd. Such value is correlated to the difference in the purchase cost of the two energy vectors. Furthermore, a slight variation in the CAC is observed in the case of the boiler as the fraction of hydrogen involved increases, which is due to the aforementioned increase in efficiency.

3.4. Sensitivity Analysis

The values of the LCOH and CAC are closely related to the assumptions made about the cost of hydrogen and the cost of NG. In order to assess how the future cost of hydrogen production affects the techno-economic parameters used in this paper, a sensitivity analysis was carried out. The LCOH and CAC values were evaluated by changing the hydrogen price. The latter can be identified as the Levelized Cost of Hydrogen (LCOH2) production, transmission, and distribution, which represents the total cost of hydrogen distributed evenly over the lifetime of the production plant. In the reference scenario, such cost was considered equal to 5 EUR/kg in order to take into consideration current hydrogen production costs. In the sensitivity analysis, a decrease of up to 1 EUR/kg was considered. This assessment is based on the assumption of a high future market penetration of the hydrogen vector, which would lead to a reduction in purchase costs. As with all scale economies, the increase in hydrogen production would reduce production costs through process optimization and increased efficiency. Achieving such a low price threshold for the purchase of hydrogen would, in fact, allow a much greater penetration of this vector within the energy system.
Figure 6 illustrates the trend of the LCOH as the LCOH2 varies. The forthcoming hydrogen price reduction allows the LCOH to be substantially reduced in the different scenarios. The two lines representing mixtures with fH2,vol of 30% exhibit a steeper slope than those representing mixtures with 10% volume fraction. The graph illustrates that, at the same LCOH2, the use of the GAHP is less expensive than the configuration with the boiler. However, this difference decreases as the price of hydrogen decreases. Moreover, it can be observed that, for a given fH2,vol, the GAHP consistently exhibits a lower LCOH. In detail, when the LCOH2 is equal to 1 EUR/kg, the most advantageous configuration is that which involves the GAHP fed by a 30% fH2,vol mixture. As shown in Figure 6, the threshold values between the GAHP (10%) and GAHP (30%) lines and between the Boiler (10%) and Boiler (30%) lines, respectively, represent the point at which the purchase cost of hydrogen equals the purchase cost of natural gas. At higher hydrogen prices, blending within the system is no longer cost-effective. The LCOH2 values resulting from the intersection of the aforementioned straight lines are 3.17 EUR/kg and 3.38 EUR/kg for the GAHP and boiler, respectively. The meeting point of the two straight lines for boiler technology is slightly displaced to the right. This phenomenon can be attributed to the variation in the efficiency of the device as the percentage of hydrogen used changes, which therefore balances out the purchase price even for a slightly higher cost.
Figure 7 illustrates the CAC trend as a function of the LCOH2 value. The configuration characterized by the boiler is more susceptible to fluctuations in the LCOH2 since the only variable is the fuel cost. Conversely, for the GAHP configuration, there are fixed installation and maintenance costs that are constant beyond the fuel, thus reducing the significance of the variation linked to the LCOH2. The CAC values linked to the GAHP system are consistently negative, indicating that the intervention is advantageous across the entire LCOH2 range under consideration, with the exception of the final point on the GAHP straight line (30%), which becomes marginally positive. It can be observed that up to an LCOH2 of 3 EUR/kg, the boiler configuration is more convenient than the GAHP, as no expenditure is required to replace the existing system. Consequently, while Figure 7 indicates that the GAHP configuration is cost-effective for low hydrogen purchase values, Figure 8 indicates that the boiler configuration is more cost-effective.
Figure 8 and Figure 9, on the other hand, show the variation in the LCOH and CAC as a function of both the price of natural gas and the LCOH2. The NG price was considered to be equal to two values representing the maximum and minimum observed in Ref. [60], equal to 121 EUR/MWh and 63 EUR/MWh, respectively. This analysis allows us to assess how the variation in the cost of the two fuels, taking into account a 30% hydrogen content in the blend, affects the cost of heat production and the reduction in emissions.
As demonstrated in the sensitivity analysis above, an increase in the LCOH2 results in an increase in the LCOH. However, Figure 8 shows that the LCOH is more influenced by the NG price than by the hydrogen price, as evidenced by the gentle slopes of the straight lines. This is undoubtedly related to the fact that NG still represents the largest volumetric share in the mixture, 70% volumetric in this case, and to the considerable price variations assessed for natural gas. In fact, considering an initial configuration characterized by an NG price of 93 EUR/MWh and a hydrogen price of 5 EUR/kg, the increase that occurs with an NG price of 121 EUR/MWh is 21.27% for the boiler and 16.63% for the GAHP, whereas with a price of 63 EUR/MWh, there is a decrease of 22.79% and 17.81% respectively, for the boiler and the GAHP. This analysis demonstrates that at a low natural gas (NG) cost, the boiler is more cost-effective than the gas absorption heat pump (GAHP), regardless of the Levelized Cost of Heat, despite the GAHP’s superior efficiency. This is due to the higher installation cost of the GAHP, which is not offset by the lower cost of NG. On the other hand, a higher NG price demonstrates the advantage of using the GAHP system, which has a higher efficiency.
Figure 9 illustrates the variation in the CAC as the price of NG and H2 fluctuates, with a constant 30% by volume hydrogen mixture. Upon examination of the boiler and the GAHP individually, it becomes evident that as the cost of natural gas increases, the corresponding values for the Carbon Abatement Cost also increase. For each of the three values considered for the price of NG, it can be observed that for an LCOH2 of 3 EUR/kg, the two technologies are equivalent. This hydrogen price is, therefore, the one that compensates for the purchase difference between the two analyzed energy sources. With an NG price of 121 EUR/MWh, it is evident that an LCOH2 of 4 EUR/kg is sufficient to eliminate the CAC and thus the cost of reducing emissions. On the other hand, for a lower NG price of 63 EUR/MWh, an LCOH2 value of around 2 EUR/kg is required to make the use of hydrogen for the boiler economically viable. In contrast, when considering the system with the GAHP, it can be observed that at low NG prices, the CAC remains positive for any H2 cost considered, making the system unprofitable.
In summary, the integration of hydrogen carriers into the natural gas infrastructure can help reduce consumption and emissions from heating systems. However, the ultimate goal for decarbonizing the residential sector lies in the electrification of low-temperature heat demand. While GAHPs can reduce emissions in the short term, further investment in natural gas technologies could lead to the risk of creating stranded assets.
This research shows that the costs of decarbonization remain lower when hydrogen prices are below 3 EUR/kg, without the necessity to replace boilers with GAHPs. Consequently, the use of H2NG blends can effectively reduce the emissions associated with natural gas, with no need for further investments in gas infrastructure. This strategy allows to reduce carbon emissions without disrupting the shift towards electrification of energy consumption. A complete overhaul of heating systems is desirable, but this would be challenging to realize in the short–medium term. Hydrogen blending can contribute to the decarbonization of the not-yet electrified heating demand and in the meantime boost the deployment of hydrogen technologies. Therefore, the implementation of national hydrogen policies should not delay the process of end-use electrification. This approach can be suitable, especially for countries such as Italy, where the heating sector is heavily reliant on natural gas.
In addition, the potential interrelationships and synergies between gas-based and electrification-based decarbonization strategies in the energy transition are issues that can be further explored in future developments of this work.

4. Conclusions

This work aims to assess the technical, economic, and environmental impacts of hydrogen blending on the condensing boiler and GAHP systems in a building. Furthermore, a detailed sensitivity analysis was carried out to evaluate the impact of varying hydrogen and natural gas costs.
The main findings of this study can be summarized as follows:
  • The use of the GAHP results in a reduced non-renewable primary energy consumption compared with the boiler of up to 25.69%. The GAHP records an EPnr,t of 93.18 MWh/y when fueled with 30% vol. of H2.
  • At a hydrogen volumetric fraction of 30%, the CO2 emissions reductions recorded for the condensing boiler and the GAHP are 12.05% and 11.19%, respectively.
  • The GAHP records a lower LCOH than NG boilers (102.26 EUR/MWh vs. 106.06 EUR/MWh) due to its higher efficiency. The greater the hydrogen rate in the blend, the greater the LCOH.
  • Due to its reduction in the overall cost of heat production, the GAHP shows negative values of CAC at fH2,vol values ranging between 0 and 20%. The economic advantage of the GAHP is reduced as the volumetric fraction of H2 used increases, which is due to the higher cost of fuel purchasing. The current hydrogen prices are correlated with high values of CAC, which are approximately 220 EUR/kgCO2,avd.
  • The forthcoming cost reduction in hydrogen will reduce the Levelized Cost of Heat and the decarbonization cost for both technologies. At a hydrogen cost of 1 EUR/kg, the LCOH for the boiler and GAHP systems are 98.49 EUR/MWh and 97.22 EUR/MWh, respectively, with a 30% vol. of hydrogen in the mixture.
In conclusion, hydrogen blending in the NG grid allows an immediate reduction in final heating consumption. Nevertheless, H2NG represents merely a bridging energy carrier toward decarbonization. In the long term, the main solution to decarbonize the building stock is the electrification of the low-temperature heat demand. Therefore, while the GAHP may reduce emissions in the short term, there is a risk of developing stranded assets by investing in additional natural gas-related technologies.
Furthermore, as shown in this article, the overall cost of decarbonization for hydrogen prices below 3 EUR/kg is lower without considering the replacement of the boiler with the GAHP. Therefore, although gas-fired boilers with high volume fractions of hydrogen lead to an increase in overall heating costs, replacement with other gas-fired heating systems may not be the best strategy in the long run. Therefore, blending hydrogen into the gas grid can be a useful policy to reduce emissions from the overall natural gas consumption, including the building sector, without contradicting the process of electrification of energy end-uses.
This policy may have a particular impact in NG-based countries, such as Italy, which has an extensive capillary gas network and where the building stock is mostly supplied by gas boilers. It is challenging to envision a complete replacement of heating systems within the next few years. Consequently, in the near future, hydrogen blending represents an intriguing approach to supporting the decarbonization process while stimulating the development of an industrial hydrogen technology supply chain.

Author Contributions

Conceptualization, D.V., A.S. and L.M.P.; methodology, A.S. and L.M.P.; software, D.V. and A.S.; formal analysis, D.V.; investigation, D.V.; data curation, D.V.; writing—original draft preparation, D.V.; writing—review and editing, A.S. and L.M.P.; supervision, G.L.B. and L.d.S.; project administration, L.d.S. and L.M.P. All authors have read and agreed to the published version of the manuscript.

Funding

The present work was funded by the European Union Next Generation EU under the PNRR (Na-tional Recovery and Resilience Plan, NEST “Network 4 Energy Sustainable Transition”, PE2 NEST Spoke 4, B53C22004070006; PNRR, Missione 4, Componente 2, Investimento 1.3, finanziato dall’Unione europea, NextGenerationEU).

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

Nomenclature
CCosts (EUR/yr)
CAPEXInitial Capital Expenditure (EUR)
CO2,eqAnnual CO2 equivalent emissions (tCO2/yr)
EthThermal energy required (MWh/yr)
EH2NGThermal energy from fuel (MWh/yr)
EfH2Thermal energy from hydrogen fraction (MWh/yr)
EPPrimary energy consumption (MWh/yr)
fH2,volHydrogen volumetric fraction
fe,NGEmission factor (kgCO2/MWh)
fnr,NGNon-renewable primary energy factor
iinterest rate (%)
PThermal power (kW)
PH2NGThermal power from fuel (MW)
PH2Price of hydrogen (EUR/kg)
PNGPrice of natural gas (EUR/MWh)
tLifetime (yr)
yi,H2Hydrogen Mass Fraction
ΔTTemperature difference between exhaust gas and external air (°C)
ηboilerBoiler efficiency
ηGAHPGas Adsorption Heat Pump efficiency
ηcondCondensation efficiency
ηcCombustion efficiency
Subscripts
DDemand
fuelFossil fuel
latentLatent heat losses
loss, sensSensible heat losses
nrNon-renewable energy
O&MOperation and maintenance
thThermal
Abbreviations and Acronyms
CACCarbon Abatement Cost
crfCapital recovery factor
EFCEnergy Fraction of Condensation
GAHPGas Adsorption Heat Pump
GHGGreenhouse gas
H2NGHydrogen-enriched natural gas blends
HHVHigher heating value
HVRHeating Value Ratio
LCOHLevelized Cost of Heat
LCOH2Levelized Cost of Hydrogen
LHVLower heating value
NGNatural gas
SNGSynthetic natural gas

References

  1. Rabiee, A.; Keane, A.; Soroudi, A. Green Hydrogen: A New Flexibility Source for Security Constrained Scheduling of Power Systems with Renewable Energies. Int. J. Hydrogen Energy 2021, 46, 19270–19284. [Google Scholar] [CrossRef]
  2. Lund, H.; Andersen, A.N.; Østergaard, P.A.; Mathiesen, B.V.; Connolly, D. From Electricity Smart Grids to Smart Energy Systems—A Market Operation Based Approach and Understanding. Energy 2012, 42, 96–102. [Google Scholar] [CrossRef]
  3. Sgaramella, A.; Pastore, L.M.; Lo Basso, G.; de Santoli, L. Optimal RES Integration for Matching the Italian Hydrogen Strategy Requirements. Renew Energy 2023, 219, 119409. [Google Scholar] [CrossRef]
  4. Brey, J.J. Use of Hydrogen as a Seasonal Energy Storage System to Manage Renewable Power Deployment in Spain by 2030. Int. J. Hydrogen Energy 2021, 46, 17447–17457. [Google Scholar] [CrossRef]
  5. Caglayan, D.G.; Heinrichs, H.U.; Robinius, M.; Stolten, D. Robust Design of a Future 100% Renewable European Energy Supply System with Hydrogen Infrastructure. Int. J. Hydrogen Energy 2021, 46, 29376–29390. [Google Scholar] [CrossRef]
  6. Field, C.B.; Barros, V.R.; Dokken, D.J.; Mach, K.J.; Mastrandrea, M.D. (Eds.) Climate Change 2014 Impacts, Adaptation, and Vulnerability; Cambridge University Press: Cambridge, UK, 2014; ISBN 9781107415379. [Google Scholar]
  7. Abdin, Z.; Zafaranloo, A.; Rafiee, A.; Mérida, W.; Lipiński, W.; Khalilpour, K.R. Hydrogen as an Energy Vector. Renew. Sustain. Energy Rev. 2020, 120, 109620. [Google Scholar] [CrossRef]
  8. van Wijk, A.; Chatzimarkakis, J. Green Hydrogen for a European Green Deal: A 2x40 GW Initiative; Hydrogen Europe: Brussels, Belgium, 2021. [Google Scholar]
  9. European Commission. A Clean Planet for All: A European Long-Term Strategic Vision for a Prosperous, Modern, Competitive and Climate Neutral Economy; European Commission: Brussels, Belgium, 2018. [Google Scholar]
  10. Nikolaidis, P.; Poullikkas, A. A Comparative Overview of Hydrogen Production Processes. Renew. Sustain. Energy Rev. 2017, 67, 597–611. [Google Scholar] [CrossRef]
  11. Hanley, E.S.; Deane, J.; Gallachóir, B.Ó. The Role of Hydrogen in Low Carbon Energy Futures–A Review of Existing Perspectives. Renew. Sustain. Energy Rev. 2018, 82, 3027–3045. [Google Scholar] [CrossRef]
  12. Liu, F.; Mauzerall, D.L.; Zhao, F.; Hao, H. Deployment of Fuel Cell Vehicles in China: Greenhouse Gas Emission Reductions from Converting the Heavy-Duty Truck Fleet from Diesel and Natural Gas to Hydrogen. Int. J. Hydrogen Energy 2021, 46, 17982–17997. [Google Scholar] [CrossRef]
  13. Herwartz, S.; Pagenkopf, J.; Streuling, C. Sector Coupling Potential of Wind-Based Hydrogen Production and Fuel Cell Train Operation in Regional Rail Transport in Berlin and Brandenburg. Int. J. Hydrogen Energy 2021, 46, 29597–29615. [Google Scholar] [CrossRef]
  14. Choi, C.H.; Yu, S.; Han, I.-S.; Kho, B.-K.; Kang, D.-G.; Lee, H.Y.; Seo, M.-S.; Kong, J.-W.; Kim, G.; Ahn, J.-W.; et al. Development and Demonstration of PEM Fuel-Cell-Battery Hybrid System for Propulsion of Tourist Boat. Int. J. Hydrogen Energy 2016, 41, 3591–3599. [Google Scholar] [CrossRef]
  15. Gutiérrez-Martín, F.; Rodríguez-Antón, L.M. Power-to-SNG Technologies by Hydrogenation of CO2 and Biomass Resources: A Comparative Chemical Engineering Process Analysis. Int. J. Hydrogen Energy 2019, 44, 12544–12553. [Google Scholar] [CrossRef]
  16. Stančin, H.; Mikulčić, H.; Wang, X.; Duić, N. A Review on Alternative Fuels in Future Energy System. Renew. Sustain. Energy Rev. 2020, 128, 109927. [Google Scholar] [CrossRef]
  17. Kurtz, J.; Sprik, S.; Bradley, T.H. Review of Transportation Hydrogen Infrastructure Performance and Reliability. Int. J. Hydrogen Energy 2019, 44, 12010–12023. [Google Scholar] [CrossRef]
  18. Wahl, J.; Kallo, J. Quantitative Valuation of Hydrogen Blending in European Gas Grids and Its Impact on the Combustion Process of Large-Bore Gas Engines. Int. J. Hydrogen Energy 2020, 45, 32534–32546. [Google Scholar] [CrossRef]
  19. Gondal, I.A. Hydrogen Integration in Power-to-Gas Networks. Int. J. Hydrogen Energy 2019, 44, 1803–1815. [Google Scholar] [CrossRef]
  20. Qadrdan, M.; Abeysekera, M.; Chaudry, M.; Wu, J.; Jenkins, N. Role of Power-to-Gas in an Integrated Gas and Electricity System in Great Britain. Int. J. Hydrogen Energy 2015, 40, 5763–5775. [Google Scholar] [CrossRef]
  21. Jones, D.R.; Al-Masry, W.A.; Dunnill, C.W. Hydrogen-Enriched Natural Gas as a Domestic Fuel: An Analysis Based on Flash-Back and Blow-off Limits for Domestic Natural Gas Appliances within the UK. Sustain. Energy Fuels 2018, 2, 710–723. [Google Scholar] [CrossRef]
  22. Schiro, F.; Stoppato, A.; Benato, A. Modelling and Analyzing the Impact of Hydrogen Enriched Natural Gas on Domestic Gas Boilers in a Decarbonization Perspective. Carbon Resour. Convers. 2020, 3, 122–129. [Google Scholar] [CrossRef]
  23. Sgaramella, A.; Lo Basso, G.; de Santoli, L. How the Cylinder Initial Conditions Affect the HCNG Refuelling Process—A Thermodynamic Analysis to Determine the Most Effective Filling Parameters. Int. J. Hydrogen Energy 2024, 51, 559–575. [Google Scholar] [CrossRef]
  24. Jeon, J.; Kim, S.J. Recent Progress in Hydrogen Flammability Prediction for the Safe Energy Systems. Energies 2020, 13, 6263. [Google Scholar] [CrossRef]
  25. Acar, C.; Dincer, I. Review and Evaluation of Hydrogen Production Options for Better Environment. J. Clean. Prod. 2019, 218, 835–849. [Google Scholar] [CrossRef]
  26. Pluvinage, G. Mechanical Properties of a Wide Range of Pipe Steels under Influence of Pure Hydrogen or Hydrogen Blended with Natural Gas. Int. J. Press. Vessel. Pip. 2021, 190, 104293. [Google Scholar] [CrossRef]
  27. Quarton, C.J.; Samsatli, S. Should We Inject Hydrogen into Gas Grids? Practicalities and Whole-System Value Chain Optimisation. Appl. Energy 2020, 275, 115172. [Google Scholar] [CrossRef]
  28. Chintala, V.; Subramanian, K.A. Hydrogen Energy Share Improvement along with NOx (Oxides of Nitrogen) Emission Reduction in a Hydrogen Dual-Fuel Compression Ignition Engine Using Water Injection. Energy Convers. Manag. 2014, 83, 249–259. [Google Scholar] [CrossRef]
  29. WHITE, C.; STEEPER, R.; LUTZ, A. The Hydrogen-Fueled Internal Combustion Engine: A Technical Review. Int. J. Hydrogen Energy 2006, 31, 1292–1305. [Google Scholar] [CrossRef]
  30. Choudhury, S.; McDonell, V.G.; Samuelsen, S. Combustion Performance of Low-NOx and Conventional Storage Water Heaters Operated on Hydrogen Enriched Natural Gas. Int. J. Hydrogen Energy 2020, 45, 2405–2417. [Google Scholar] [CrossRef]
  31. The European House–Ambrosetti, Snam. H2 Italy 2050; ENEA: Roma, Italy, 2020.
  32. Pniec, Piano Nazionale Integrato Per L’Energia E IL Clima; Ministero Dell’Ambiente e Della Sicurezza Energetica: Roma, Italy, 2023.
  33. van Renssen, S. The Hydrogen Solution? Nat. Clim. Chang. 2020, 10, 799–801. [Google Scholar] [CrossRef]
  34. Pastore, L.M.; Lo Basso, G.; de Santoli, L. How National Decarbonisation Scenarios Can Affect Building Refurbishment Strategies. Energy 2023, 283, 128634. [Google Scholar] [CrossRef]
  35. Lamioni, R.; Bronzoni, C.; Folli, M.; Tognotti, L.; Galletti, C. Feeding H2-Admixtures to Domestic Condensing Boilers: Numerical Simulations of Combustion and Pollutant Formation in Multi-Hole Burners. Appl. Energy 2022, 309, 118379. [Google Scholar] [CrossRef]
  36. Yang, H.; Lin, X.; Pan, H.; Geng, S.; Chen, Z.; Liu, Y. Energy Saving Analysis and Thermal Performance Evaluation of a Hydrogen-Enriched Natural Gas-Fired Condensing Boiler. Int. J. Hydrogen Energy 2023, 48, 19279–19296. [Google Scholar] [CrossRef]
  37. Sforzini, M.; Lo Basso, G.; Paiolo, R.; De Santoli, L.; Cumo, F. Adsorption Gas Heat Pump Fuelled with Hydrogen Enriched Natural Gas Blends: The Analytical Simulation Model Development and Validation. E3S Web Conf. 2020, 197, 08002. [Google Scholar] [CrossRef]
  38. Yan, F.; Xu, L.; Wang, Y. Application of Hydrogen Enriched Natural Gas in Spark Ignition IC Engines: From Fundamental Fuel Properties to Engine Performances and Emissions. Renew. Sustain. Energy Rev. 2018, 82, 1457–1488. [Google Scholar] [CrossRef]
  39. Mehra, R.K.; Duan, H.; Juknelevičius, R.; Ma, F.; Li, J. Progress in Hydrogen Enriched Compressed Natural Gas (HCNG) Internal Combustion Engines—A Comprehensive Review. Renew. Sustain. Energy Rev. 2017, 80, 1458–1498. [Google Scholar] [CrossRef]
  40. Zhao, Y.; McDonell, V.; Samuelsen, S. Experimental Assessment of the Combustion Performance of an Oven Burner Operated on Pipeline Natural Gas Mixed with Hydrogen. Int. J. Hydrogen Energy 2019, 44, 26049–26062. [Google Scholar] [CrossRef]
  41. Zhang, Y.; Qin, C.; Xing, H.; Liu, P. Experimental Research on Performance Response of Domestic Gas Cookers to Variable Natural Gas Constituents. J. Nat. Gas. Sci. Eng. 2013, 10, 41–50. [Google Scholar] [CrossRef]
  42. Cellek, M.S.; Pınarbaşı, A. Investigations on Performance and Emission Characteristics of an Industrial Low Swirl Burner While Burning Natural Gas, Methane, Hydrogen-Enriched Natural Gas and Hydrogen as Fuels. Int. J. Hydrogen Energy 2018, 43, 1194–1207. [Google Scholar] [CrossRef]
  43. Kouchachvili, L.; Entchev, E. Power to Gas and H2/NG Blend in SMART Energy Networks Concept. Renew. Energy 2018, 125, 456–464. [Google Scholar] [CrossRef]
  44. Cinti, G.; Bidini, G.; Hemmes, K. Comparison of the Solid Oxide Fuel Cell System for Micro CHP Using Natural Gas with a System Using a Mixture of Natural Gas and Hydrogen. Appl. Energy 2019, 238, 69–77. [Google Scholar] [CrossRef]
  45. Rajpara, P.; Shah, R.; Banerjee, J. Effect of Hydrogen Addition on Combustion and Emission Characteristics of Methane Fuelled Upward Swirl Can Combustor. Int. J. Hydrogen Energy 2018, 43, 17505–17519. [Google Scholar] [CrossRef]
  46. Pastore, L.M.; Lo Basso, G.; Ricciardi, G.; de Santoli, L. Smart Energy Systems for Renewable Energy Communities: A Comparative Analysis of Power-to-X Strategies for Improving Energy Self-Consumption. Energy 2023, 280, 128205. [Google Scholar] [CrossRef]
  47. Mancini, F.; Salvo, S.; Piacentini, V. Issues of Energy Retrofitting of a Modern Public Housing Estates: The ‘Giorgio Morandi’ Complex at Tor Sapienza, Rome, 1975-1979. Energy Procedia 2016, 101, 1111–1118. [Google Scholar] [CrossRef]
  48. European Commission. HotMaps, the Open Source Mapping and Planning Tool for Heating and Cooling; European Commission: Brussels, Belgium, 2020. [Google Scholar]
  49. Lo Basso, G.; Nastasi, B.; Astiaso Garcia, D.; Cumo, F. How to Handle the Hydrogen Enriched Natural Gas Blends in Combustion Efficiency Measurement Procedure of Conventional and Condensing Boilers. Energy 2017, 123, 615–636. [Google Scholar] [CrossRef]
  50. UNI 10389-1:2019; Misurazioni in Campo—Generatori di Calore—Parte 1: Apparecchi Alimentati a Combustibile Liquido e/o Gassoso. 2019. Available online: https://StoreUniCom/Uni-10389-1-2019 (accessed on 8 June 2024).
  51. UNI 10339:1995; Impianti Aeraulici al fini di Benessere. Generalità, Classificazione e Requisiti. Regole per la Richiesta D’offerta, L’offerta, L’ordine e la Fornitura. 1995. Available online: https://StoreUniCom/Uni-10339-1995 (accessed on 8 June 2024).
  52. ISPRA Istituto Superiore per La Protezione e La Ricerca Ambientale. Fattori Di Emissione Atmosferica Di Gas a Effetto Serra Nel Settore Elettrico Nazionale e Nei Principali Paesi Europei; ISPRA Istituto Superiore per La Protezione e La Ricerca Ambientale: Roma, Italy, 2019. [Google Scholar]
  53. Ravi Kumar, K.; Krishna Chaitanya, N.V.V.; Sendhil Kumar, N. Solar Thermal Energy Technologies and Its Applications for Process Heating and Power Generation—A Review. J. Clean. Prod. 2021, 282, 125296. [Google Scholar] [CrossRef]
  54. Meesenburg, W.; Ommen, T.; Thorsen, J.E.; Elmegaard, B. Economic Feasibility of Ultra-Low Temperature District Heating Systems in Newly Built Areas Supplied by Renewable Energy. Energy 2020, 191, 116496. [Google Scholar] [CrossRef]
  55. Wang, Z. Heat Pumps with District Heating for the UK’s Domestic Heating: Individual versus District Level. Energy Procedia 2018, 149, 354–362. [Google Scholar] [CrossRef]
  56. Danish Energy Agency. Technology Data—Energy Plants for Electricity and District Heating Generation. 2016. Available online: http://www.ens.dk/teknologikatalog (accessed on 8 June 2024).
  57. Sgaramella, A.; Pastore, L.M.; Lo Basso, G.; Mojtahed, A.; de Santoli, L. HCNG Refuelling Station to Accelerate the Transition towards a Real Hydrogen Economy: A Techno-Economic Analysis. Int. J. Hydrogen Energy 2024, 69, 1403–1416. [Google Scholar] [CrossRef]
  58. Ciancio, A.; Lo Basso, G.; Pastore, L.M.; de Santoli, L. Carbon Abatement Cost Evolution in the Forthcoming Hydrogen Valleys by Following Different Hydrogen Pathways. Int. J. Hydrogen Energy 2024, 64, 80–97. [Google Scholar] [CrossRef]
  59. Prakash, V.; Ghosh, S.; Kanjilal, K. Costs of Avoided Carbon Emission from Thermal and Renewable Sources of Power in India and Policy Implications. Energy 2020, 200, 117522. [Google Scholar] [CrossRef]
  60. ARERA–Prezzi e Tariffe. Available online: https://www.arera.it/area-operatori/prezzi-e-tariffe (accessed on 1 June 2024).
  61. IEA. Global Hydrogen Review 2022; IEA: Paris, France, 2022. [Google Scholar]
  62. Heat Roadmap Europe 4 (HRE4). EnergyPLAN 2018. Available online: https://www.energyplan.eu/hre4/ (accessed on 16 July 2024).
  63. Heat Pump Strategy Report; World Liquid Gas: Neuilly-sur-Seine, France, 2022.
Figure 1. Annual heating demand for the different dwellings, surface of each dwelling, and total heating demand.
Figure 1. Annual heating demand for the different dwellings, surface of each dwelling, and total heating demand.
Buildings 14 02284 g001
Figure 2. Non-renewable primary energy consumption and CO2 emissions for the boiler and GAHP systems with changes in hydrogen fraction.
Figure 2. Non-renewable primary energy consumption and CO2 emissions for the boiler and GAHP systems with changes in hydrogen fraction.
Buildings 14 02284 g002
Figure 3. Price variation in the H2NG mixture with changes in hydrogen fraction and NG price.
Figure 3. Price variation in the H2NG mixture with changes in hydrogen fraction and NG price.
Buildings 14 02284 g003
Figure 4. Levelized Cost of Heat for the boiler and GAHP systems with changes in hydrogen fraction.
Figure 4. Levelized Cost of Heat for the boiler and GAHP systems with changes in hydrogen fraction.
Buildings 14 02284 g004
Figure 5. Carbon Abatement Cost for the boiler and GAHP systems with changes in hydrogen fraction.
Figure 5. Carbon Abatement Cost for the boiler and GAHP systems with changes in hydrogen fraction.
Buildings 14 02284 g005
Figure 6. Sensitivity analysis of the LCOH for the boiler and GAHP systems with changes in hydrogen fraction and hydrogen price.
Figure 6. Sensitivity analysis of the LCOH for the boiler and GAHP systems with changes in hydrogen fraction and hydrogen price.
Buildings 14 02284 g006
Figure 7. Sensitivity analysis of the CAC for the boiler and GAHP systems with changes in hydrogen fraction and hydrogen price.
Figure 7. Sensitivity analysis of the CAC for the boiler and GAHP systems with changes in hydrogen fraction and hydrogen price.
Buildings 14 02284 g007
Figure 8. Sensitivity analysis of the LCOH for the boiler and GAHP systems with changes in NG and hydrogen prices with fixed H2 volumetric fraction.
Figure 8. Sensitivity analysis of the LCOH for the boiler and GAHP systems with changes in NG and hydrogen prices with fixed H2 volumetric fraction.
Buildings 14 02284 g008
Figure 9. Sensitivity analysis of the CAC for the boiler and GAHP systems with changes in NG and hydrogen prices with fixed H2 volumetric fraction.
Figure 9. Sensitivity analysis of the CAC for the boiler and GAHP systems with changes in NG and hydrogen prices with fixed H2 volumetric fraction.
Buildings 14 02284 g009
Table 1. Dwelling characteristics and heating demand [46].
Table 1. Dwelling characteristics and heating demand [46].
Dwelling
Typology/Building
Number of DwellingsSurface (m2)Annual Heating Demand
(MWh/yr)
Annual Electrical Consumption (MWh/yr)INHABITANTS (n° of People)
A5604.224.752
B5674.719.553
C51349.4212.654
D51379.6312.53
Building201990139.939.4560
Table 2. Parameter calculation required with changes in hydrogen fraction [49].
Table 2. Parameter calculation required with changes in hydrogen fraction [49].
fH2 (% vol.)K1K2HVRηcond
00.0078522.27425 × 10−51.10620.549
100.0078082.23817 × 10−51.10840.565
200.0077562.19601 × 10−51.11090.581
300.0076952.14608 × 10−51.11390.597
Table 3. Boiler’s combustion efficiency with changes in hydrogen fraction.
Table 3. Boiler’s combustion efficiency with changes in hydrogen fraction.
fH2 (% vol.)ηc
01.04034
101.04340
201.04671
301.05043
Table 4. Density and LHV values for H2NG mixtures [49].
Table 4. Density and LHV values for H2NG mixtures [49].
fH2 (% vol.)ρn (kg/Nm3)LHVH2NG,mass (MJ/kg)LHVH2NG,vol (MJ/Nm3)
00.71749.9835.857
100.65550.9933.3822
200.59252.2230.9074
300.52953.7328.4326
Table 5. Techno-economic assumptions for the condensing boiler and GAHP systems [46,56,62].
Table 5. Techno-economic assumptions for the condensing boiler and GAHP systems [46,56,62].
TechnologyCAPEX (EUR/kW)O&M Costs (% of CAPEX)Lifetime (y)Ref.
Boiler2284.915[46,56,62]
GAHP4294.920[56,62,63]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Vespasiano, D.; Sgaramella, A.; Lo Basso, G.; de Santoli, L.; Pastore, L.M. Hydrogen Blending in Natural Gas Grid: Energy, Environmental, and Economic Implications in the Residential Sector. Buildings 2024, 14, 2284. https://doi.org/10.3390/buildings14082284

AMA Style

Vespasiano D, Sgaramella A, Lo Basso G, de Santoli L, Pastore LM. Hydrogen Blending in Natural Gas Grid: Energy, Environmental, and Economic Implications in the Residential Sector. Buildings. 2024; 14(8):2284. https://doi.org/10.3390/buildings14082284

Chicago/Turabian Style

Vespasiano, Domiziana, Antonio Sgaramella, Gianluigi Lo Basso, Livio de Santoli, and Lorenzo Mario Pastore. 2024. "Hydrogen Blending in Natural Gas Grid: Energy, Environmental, and Economic Implications in the Residential Sector" Buildings 14, no. 8: 2284. https://doi.org/10.3390/buildings14082284

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics