Advancing Motivation Feedforward Control of Permanent Magnetic Linear Oscillating Synchronous Motor for High Tracking Precision

1
School of Automation Science and Electrical Engineering, Beihang University, Beijing 100191, China
2
Ningbo Institute of Technology, Beihang University, Ningbo 315800, China
3
Science and Technology on Aircraft Control Laboratory, Beihang University, Beijing 100191, China
*
Author to whom correspondence should be addressed.
Actuators 2021, 10(6), 128; https://doi.org/10.3390/act10060128
Submission received: 29 April 2021 / Revised: 24 May 2021 / Accepted: 3 June 2021 / Published: 10 June 2021
(This article belongs to the Section Control Systems)

Abstract

:
Linear motors have promising application to industrial manufacture because of their direct motion and thrust output. A permanent magnetic linear oscillating synchronous motor (PMLOSM) provides reciprocating motion which can drive a piston pump directly having advantages of high frequency, high reliability, and easy commercial manufacture. Hence, researching the tracking performance of PMLOSM is of great importance to realizing its popularization and application. Traditional PI control cannot fulfill the requirement of high tracking precision, and PMLOSM performance has high phase lag because of high control stiffness. In this paper, an advancing motivation feedforward control (AMFC), which is a combination of advancing motivation signal and PI control signal, is proposed to obtain high tracking precision of PMLOSM. The PMLOSM inserted with AMFC can provide accurate trajectory tracking at a high frequency. Compared with single PI control, AMFC can reduce the phase lag from −18 to −2.7 degrees, which shows great promotion of the tracking precision of PMLOSM. In addition, AMFC will promote the application of PMLOSM to other working conditions needing high frequency reciprocating tracking performance and give PMLOSM greater future prospects.

1. Introduction

Linear motors can provide direct motion without any other transmission gears or power producers such as fluid pumps and air compressors, so the linear motor has been vitally applied to rail transit [1], flexible beam systems [2], biaxial systems [3], maglev transportation systems [4], printer gantry positioning [5], H-shape gantry control [6], and other applications that require fast smooth operation [7] or high frequency response [8]. The PMLOSM is a permanent magnetic linear synchronous motor that has been inserted in high stiffness springs to make up the mover as a typical secondary order mass-spring system and can provide high frequency reciprocating motion, so PMLOSMs can be a core component for a directly driven linear hydraulic pump with enough power density [9].
In recent years, researchers have centered on the linear motor performance of faster transient response [10,11,12], tracking accuracy [13,14,15], and high robustness [16,17,18,19]. The performance of linear motors is influenced by many factors such as parameter uncertainties [11,20], nonlinear friction, kinematic and dynamic constraints [14], nonlinear electromagnetic field [21], exogenous disturbance [22], cogging force [10], and back electromagnetic force [23]. Various approaches are related to linear motor control such as multiple input–output control [10], network control [11,19], speed estimation [12], sliding mode control [15,16,21,24,25,26], iterative learning control [17], adaptive robust control [10], sensorless control [23,27,28], backstepping control [29], and impedance control [30,31]. A novel multiple-input multiple-output space-state control model improves direct thrust force control leading to faster transient response of permanent magnetic linear synchronous motor [10]. A radial basis function network control satisfies good transient performance of the linear motor through lumping uncertainties including parameter variations, external disturbances and nonlinear friction force at tracking frequency of 0.25 Hz [11]. A sliding mode controller, injected with estimated speed, is constructed to ensure the accuracy and robustness for linear permanent magnetic synchronous motor (PMLSM) [16], and an adaptive recursive sliding mode control conquers deterioration of parameter uncertainty, nonlinear friction, and exogenous disturbance for the linear motor to get high speed and high precision performance at about 1 Hz [21]. An adaptive robust controller, taking into account nonlinear electromagnetic field, is designed to obtain accurate trajectory performance at 1 Hz [21]. An adaptive backstepping control strategy is provided to obtain satisfied performance of position tracking ability and control robustness for PMLSM [29]. Sensorless control is conducted on linear motor via extended Kalman filter [27,28]. A typical PID controller is designed for the asymmetric bilateral linear hybrid switched reluctance motor to obtain high-accuracy position performance at 0.5 Hz [32].
All these linear motor control studies cannot match PMLOSM it its high tracking precision because of high stiffness, high operating frequency, and low sampling times. High stiffness springs are inserted in the mover of the PMLOSM to give a mass-spring second order system so that the mover can oscillate as a trigonometric waveform at high frequency, which undoubtedly challenges the phase response of PMLOSM. Fortunately, researchers have explored some control strategies for PMLOSM. Yang proposed a dual feedback and feedforward controller for stroke and phase compensation [30] indicating that stroke and phase should each be taken into consideration for high tracking precision of PMLOSM. Du proposed a model-based feedforward controller that practically improved the phase response of linear oscillating motor [31]. Wang introduced B-spline neural network compensator as feedforward control to obtain better performance, but required more conditions to satisfy learning process of feedforward coefficient [33]. These studies indicate that feedforward control can improve phase response. For stroke control, traditional PI control of PMLOSM has the advantages of convenient adjustment and robustness, but cannot cope with phase delay [34]. Though Kim studied PID control on PMLOSM on improving phase response, noise and disturbance of the derivative element led to insufficient control performance [35]. Input and output signals should be taken into consideration for a more efficient controller [36]. Integral action and anticipatory action are taken into consideration mainly in controller design for linear motor position control [37]. Above all, we combined traditional PI control and feedforward control as a two-degree-of-freedom controller [38], to obtain high tracking precision of PMLOSM.
In this paper, we provide an advancing motivation feedforward control (AMFC) strategy for PMLOSM. In Section 2, the structure and problem illustration are given. In Section 3, the mathematical model and simulation analysis are given. In Section 4, the experiment results are given. In Section 5, conclusion is given.

2. Structure and Problem Illustration

The PMLOSM can provide reciprocating motion at a high frequency because of an inserted hard spring into the mover to construct a second order mass-spring system. The cross section of the PMLOSM is shown in Figure 1.
PMLOSM is composed of hard springs, stator, and mover. The stator consists of coils, silicon steel lamination, stainless steel frame and stainless steel end covers. The mover consists of Halbach permanent magnetic array and iron frame. Springs are inserted between stator and mover, so the mover becomes a typical second order system which has a high inherent frequency. A diagram of the PMLOSM is depicted in Figure 2.
The insertion of hard springs makes up a typical second order system. If the input current is of inherent frequency, PMLOSM can operate at high frequency. The open loop magnitude figure is shown in Figure 3. If PMLOSM works at inherent frequency, the efficiency of PMLOSM would be high. However, the phase lag is about 90 degrees, as shown in Figure 4. When we design a closed loop controller, it is inevitable to conquer the phase lag to obtain high tracking precision, which challenges the controller design.
Hence, we proposed AMFC for PMLOSM to obtain high tracking precision. AMFC is a combination of feedforward control and traditional PI control. Traditional PI control satisfies stroke adjustment and feedforward control improves phase response.

3. Mathematical Model and Simulation Analysis

3.1. Mathematical Model

Assume that the PMLOSM is symmetrical and the relationship between thrust and input current is linear, absolutely obtained by experiment shown in Figure 5. Hence, the electromagnetic force of the PMLOSM can be written as
F e = K e i
where F e is electromotive force of the PMLOSM; K e is force constant coefficient of the PMLOSM; i is input current.
Assume that mover is a rigid body and there is no deformation, and the dynamic function, based on Newton’s second law, can be written as
F e = k x + ξ x ˙ + m x ¨
where k is spring stiffness of PMLOSM; m is total mass of mover and piston; ξ is damping coefficient of LHP; x is displacement of mover.
Traditional PI control applied to the PMLOSM is shown in Figure 6.
The command error is written as
e = x r x
where x r is command signal.
Hence, the PI control law can be written as
u c = K i e d t + K p e
where K i is integral gain; K p is proportional gain.
The relationship between input current and control law can be written as
i = K d u c
where K d is gain of current driver.
Substitute (4) into (5), and the input current can be written as
i = K d K i e d t + K d K p e
Substitute (6) into (1), and the electromagnetic force can be written as
F e = K e K d K i e d t + K e K d K p e
Substitute (3) and (7) into (2), and the closed loop function can be written as
K e K d K i ( x r x ) d t + K e K d K p ( x r x ) = k x + ξ x ˙ + m x ¨
Perform Laplace transform at both sides of (8), and (8) can be transformed as
K e K d K i 1 s ( X r X ) + K e K d K p ( X r X ) = k X + ξ s X + m s 2 X
So the closed loop system transfer function of traditional PI control can be expressed as
X X r = K e K d K p s + K e K d K i m s 3 + ξ s 2 + ( k + K e K d K p ) s + K e K d K i
AMFC is combination of traditional PI control and feedforward control. The structure of AMFC is shown as Figure 7.
Control law of AMFC can be written as
u bc = K i e d t + K p e + u b
The driving current of PMLOSM can be written as
i bc = K d K i e d t + K d K p e + K d u b
The dynamic equation of PMLOSM can be written as
K e K d K i e d t + K e K d K p e + K e K d u b = k x + ξ x ˙ + m x ¨
Substitute (3) into (13), and the dynamic equation can be written as
K e K d K i ( x r x ) d t + K e K d K p ( x r x ) + K e K d u b = k x + ξ x ˙ + m x ¨
Perform Laplace transform at both sides of (14), and (14) can be transformed as
K e K d K i 1 s ( X r X ) + K e K d K p ( X r X ) + K e K d U b = k X + ξ s X + m s 2 X
where
U b = X r G b ( s )
Substitute (16) into (15), and the equation can be written as
K e K d K i 1 s ( X r X ) + K e K d K p ( X r X ) + K e K d G b ( s ) X r = k X + ξ s X + m s 2 X
Hence the closed loop system transfer function of AMFC can be expressed as
X X r = K e K d K i + K e K d K p s + K e K d G b ( s ) s K e K d K i + ( k + K e K d K p ) s + ξ s 2 + m s 3
If excellent performance of PMLOSM is desired, Equation (18) should be
X X r = 1
Hence the transfer function of feedforward control can be derived as
G b ( s ) = U b X r = k + ξ s + m s 2 K e K d
Perform inverse Laplace transform, Equation (20) can be expressed as
u b = 1 K e K d ( k + ξ x ˙ r + m x ¨ r )
Figure 8 depicts the features of (21).
Figure 8 shows that x r is the open loop response of u b . If x r is
x r = A sin ( 2 π f t + φ )
u b can be designed as
u b = A b sin ( 2 π f t + φ + θ )
where θ is leading phase of u b with respect of x r .
However, all analysis is linear model-based and the real physical model must be nonlinear. Hence the response of u b can be expressed as
K d K e u b = k x b + ξ x ˙ b + m x ¨ b
x b = α x r
where α is gain of AMFC.
The dynamic equation of PMLOSM can be written as
K e K d K i ( x r x ) d t + K e K d K p ( x r x ) + α k x r + α ξ x ˙ r + α m x ¨ r = k x + ξ x ˙ + m x ¨
Perform Laplace transform at both sides of (26), and (26) can be transformed as
K e K d K i 1 s ( X r X ) + K e K d K p ( X r X ) + α k X r + α ξ s X r + α m s 2 X r = k X + ξ s X + m s 2 X
Hence the system transfer function of AMFC can be expressed as
X X r = α m s 3 + α ξ s 2 + ( K e K d K p + α k ) s + K e K d K i m s 3 + ξ s 2 + ( K e K d K p + k ) s + K e K d K i

3.2. Simulation Analysis

The parameter values of PMLOSM are shown in Table 1.
If α = 0.5 , comparisons of amplitude and phase between PI control and AMFC are depicted in Figure 9 and Figure 10, respectively.
As can be seen Figure 9, the amplitude response of AMFC performs a little better than PI control at low PI parameters, and Figure 10 shows that AMFC performs much better phase response than PI control and the phase lag is reduced from 20 to 10 degrees. This indicates AMFC improves phase response and it is necessary to enhance value of α .
If the value of α increases up to 1, comparisons of amplitude and phase between PI control and AMFC are depicted in Figure 11 and Figure 12, respectively.
As can be seen Figure 11 and Figure 12, the amplitude response is 0 dB and phase lag is 0 degree invariably, showing extremely excellent performance of tracking accuracy. While it is suspected to design a motivation control signal that α = 1 exactly. Hence it is inevitable to see the result when the value of α is higher than 1.
If value of α increases up to 1.5, comparisons of amplitude and phase between PI control and AMFC are depicted in Figure 13 and Figure 14, respectively.
As can be seen in Figure 13, amplitude response performs from 0.45 to 3.5 dB, and amplitude response decreased as the proportional gain increases, indicating that PI control plays the role of restraining the amplitude response. Figure 14 depicts the phase response to be an about 10 degrees advance, indicating that AMFC leads to an advancing system of loose tracking performance at α = 1.5 .
The above simulation research shows that the performance of PMLOSM varies with the changing of motivation gain and if α = 1 , the performance of PMLOSM is of high tracking precision. For this all, it is of great importance to search effects of motivation gain α surrounding 1 on the tracking performance. Motivation gain α is set from 0.8 to 1.2 and simulation results are shown in Figure 15 and Figure 16.
As can be seen in Figure 15 and Figure 16, amplitude and phase response tend to perform better as the motivation gain α increases, except if α = 0.9 . If α = 0.9 , amplitude and phase response mainly vary with proportional gain parameter. If α = 0.8 , phase response performs well and has small phase lag from −1.2 to −2.6 degrees but the amplitude response attenuates from −1.65 to −0.48 dB. If α = 1.1 or α = 1.2 , the phase response performs well, having small phase lag but amplitude has a large overshot that may cause system disorder. Hence, motivation gain α should be set close to 1 and simulation results are shown in Figure 17 and Figure 18.
As can be seen in Figure 17 and Figure 18, both amplitude and phase response can perform well with accurate tracking performance and small fluctuation.
The above simulation results indicate that AMFC can provide high tracking accuracy for PMLOSM and perform much better than single traditional PI control. Moreover, motivation gain α plays a crucial role of tracking accuracy for PMLOSM, and motivation gain α should be set from 0.95 to 1.05 so that both amplitude and phase response can satisfy high tracking precision. Moreover, this indicates that feedforward controller has enough tolerance for experiment verification, and that even though the theoretical model has some error compared with the physical model, AMFC can provide high tracking accuracy for PMLOSM.

4. Experiment Results

The prototype of the PMLOSM and signal acquisition and control system are shown in Figure 19 and Figure 20.
At the beginning of the LHP test, parameters of PI controller are set at a low level. Proportional gain is set from 0.03 to 0.04 and integral gain is set from 0.02 to 0.05. Amplitude and phase at low PI parameters are shown in Figure 21 and Figure 22.
As can be seen in Figure 21, low PI parameters can reach a reliable amplitude response at high frequency, while Figure 22 shows that low PI parameters cannot achieve accurate phase tracking. The proportional parameter has more influence on phase response compared with that of integral parameter. Phase lag decreases as the proportional parameter becomes larger. Next step, proportional gain is set from 0.04 to 0.07 and integral gain is set from 0.03 to 0.05, and the experiments of larger proportional parameters are described in Figure 23 and Figure 24.
As can be seen in Figure 23, middle PI parameters can also satisfy the requirement of amplitude response. However, if the proportional gain continues to increase, the amplitude response tends to be divergent. Moreover, Figure 24 shows that phase lag is at a high level though, decreasing from 45 to 25 degrees as the proportional gain increases. Phase response cannot satisfy the needs of high-accuracy tracking. Hence, it is necessary to increase both proportional gain and integral gain. Then, proportional gain is set from 0.07 to 0.1 and integral gain is set from 0.06 to 0.1. Experiment result of high level parameters is depicted in Figure 25 and Figure 26.
As can be seen in Figure 25, PMLOSM would appear to system crash at the high level PI parameters. Figure 26 shows that the best performance of phase response is −18 degrees at high level PI parameters, which cannot meet the high-accuracy tracking requirement. The reason why PI control cannot settle large phase lag is that the system stiffness is high and sample time of each trigonometric wave is large. Hence, we proposed a novel method called AMFC to satisfy the requirement of high-accuracy tracking of high frequency PMLOSM.
Firstly, the PI parameters of AMFC are set as K i = 0.04 and K p = 0.02 and the motivation gain α is from 0.5 to 1. The experiment result is show in Figure 27 and Figure 28.
As can be seen in Figure 27 and Figure 28, both amplitude response and phase response reach for better performance as motivation gain α tends to be 1. Figure 27 shows that motivation gain should be larger than 0.5 so that amplitude response is larger than −3 dB. Moreover, if the motivation gain is larger than 0.8, system overshoot occurs. Figure 28 shows that the higher the motivation gain, the smaller the phase lags. If motivation gain is 1, the phase lag is −2.7 degrees. The position output is shown in Figure 29.
In [35], Kim studied the PID controller on an oscillating linear motor. The experiment results of PID control are shown from Figure 30. An experiment phase lag comparison is shown in Table 2 with respect to AMFC, PID, and PI.
AMFC obviously provided better dynamic performance than PI and PID.
The working frequency is set as 24 Hz and waveforms of current and position for one operating point of AMFC are shown in Figure 31 and Figure 32.
Figure 31 shows that AMFC can provide highly accurate position tracking for PMLOSM at high working frequency. The frequency characteristics due to different gain are in Figure 33 and Figure 34.
As can be seen in Figure 33 and Figure 34, AMFC can provide accurate position tracking at high working frequency for PMLOSM. If a small unknown force load acts on the PMLOSM, the position output is shown in Figure 35.
Figure 35 shows that AMFC has a certain degree of robustness.

5. Conclusions

Linear motors can provide direct motion without any other transmission gears or power producers such as fluid pumps and air compressors. A permanent magnetic linear oscillating synchronous motor is composed of a permanent magnetic linear synchronous motor and two springs to construct a typical second order mass-spring system, so that the permanent magnetic linear oscillating synchronous motor can provide high frequency reciprocating motion, which is challenging for controller design because of limited sampling time, high spring stiffness, and high motor operating frequency.
In this paper, detailed structure illustration and problem formulation are provided, and it is a great challenge to guarantee high tracking precision of PMLOSM because of large phase delay due to hard springs and high operating frequency. The proposed AMFC is a combination of feedforward control and traditional PI control. The simulation results show that AMFC performs better than single traditional PID control and motivation gain should be set from 0.95 to 1.05 to show that the feedforward controller has enough tolerance, which indicates that even though the theoretical model has some error compared with the physical model, AMFC can provide high tracking accuracy for PMLOSM. The experiment results show that AMFC decreases the phase lag from −18 to −2.7 degrees and maintains enough amplitude response, and AMFC can provide high tracking precision for PMLOSM at a high frequency. In conclusion, AMFC gets the hang of how to achieve high tracing precision of PMLOSM.
More illustrations: In this paper, we mainly focus on the tracking performance of PMLOSM differential control and limited robustness belongs to the motor. In addition, system analysis is based on linear model system without taking load nonlinearity into consideration. In the future, we will concentrate on load nonlinearities such as instantaneous load, constant large load, and nonlinear friction to improve the robustness of the PMLOSM.

Author Contributions

Conceptualization, Z.J., Y.C. and L.Z.; Funding acquisition, Z.J.; Project administration, Z.J.; Data curation, Y.C.; Formal analysis, Y.C. and L.Z.; Methodology, Y.C.; Resources, Y.C. and Y.L.; Validation, Z.J.; Software, X.L. and Y.L.; Investigation, L.Y.; Supervision, L.Y.; Writing—Original draft, Y.C.; Writing—Review and editing: Y.C., X.L., L.Z. and Y.L. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by, the National Key R&D Program of China under grant 2017YFB1300400 the National Natural Science Foundation of China under grants 51890882, 51875013 and 51575026, National Key Basic Research Program of China under grant 2014CB046400, the New Generation of Artificial Intelligence under grant 2018AAA0102900.

Institutional Review Board Statement

The study was conducted according to the guidelines of Science and Technology on Aircraft Control Laboratory, Beihang University, and approved by School of Automation Science and Electrical Engineering, Beihang University.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Acknowledgments

This work was supported by, the National Key R&D Program of China under grant 2017YFB1300400 the National Natural Science Foundation of China under grants 51890882, 51875013 and 51575026, National Key Basic Research Program of China under grant 2014CB046400, the New Generation of Artificial Intelligence under grant 2018AAA0102900, the Fundamental Research Funds for the Central Universities, Science and Technology on Aircraft Control Laboratory, and Ningbo Institute of Technology, Beihang University.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Li, J.Q.; Li, W.L.; Deng, G.Q.; Ming, Z. Continuous-Behavior and Discrete-Time Combined Control for Linear Induction Motor-Based Urban Rail Transit. IEEE Trans. Magn. 2016, 52, 8500104. [Google Scholar] [CrossRef]
  2. Lu, L.; Chen, Z.; Yao, B.; Wang, Q. A Two-Loop Performance-Oriented Tip-Tracking Control of a Linear-Motor-Driven Flexible Beam System with Experiments. IEEE Trans. Ind. Electron. 2013, 60, 1011–1022. [Google Scholar] [CrossRef]
  3. Hu, C.; Yao, B.; Wang, Q. Global Task Coordinate Frame-Based Contouring Control of Linear-Motor-Driven Biaxial Systems with Accurate Parameter Estimations. IEEE Trans. Ind. Electron. 2011, 58, 5195–5205. [Google Scholar] [CrossRef]
  4. Toshimitsu, M.; Kousuke, T.; Noriyuki, K. Control of Traction and Levitation of Linear Induction Motor Driven by Power Source with Frequency Component Synchronous with the Motor Speed. IEEE Trans. Magn. 2011, 47, 4302–4305. [Google Scholar] [CrossRef]
  5. Chih-Jer, L.; Her-Terng, Y.; Yun, C. Identification and Compensation of Nonlinear Friction Characteristics and Precision Control for a Linear Motor Stage. IEEE-ASME Trans. Mechatron. 2013, 18, 1385–1396. [Google Scholar] [CrossRef]
  6. Chen, Z.; Li, C.; Yao, B.; Yuan, M.; Yang, C. Integrated Coordinated/Synchronized Contouring Control of a Dual-Linear-Motor-Driven Gantry. IEEE Trans. Ind. Electron. 2020, 67, 3944–3954. [Google Scholar] [CrossRef]
  7. Hossein, K.; Sadgeh, V.; Farzad, R.S. Combined Vector and Direct Thrust Control of Linear Induction Motors with End Effect Compensation. IEEE Trans. Energy Convers. 2016, 31, 196–205. [Google Scholar] [CrossRef]
  8. Chen, Z.; Yao, B.; Wang, Q. Synthesis Based Adaptive Robust Control of Linear Motor Driven Stages with High Frequency Dynamics: A Case Study. IEEE-ASME Trans. Mechatron. 2015, 20, 1482–1490. [Google Scholar] [CrossRef]
  9. Jiao, Z.; Cao, Y.; Yan, L.; Li, X.; Zhang, L. Design and Analysis of Novel Linear Oscillating Loading System. Appl. Sci. 2019, 18, 3771. [Google Scholar] [CrossRef] [Green Version]
  10. Chen, Z.; Yao, B.; Wang, Q. Adaptive Robust Precision Motion Control of Linear Motors with Integrated Compensation of Nonlinearities and Bearing Flexible Modes. IEEE Trans. Ind. Inform. 2013, 9, 965–973. [Google Scholar] [CrossRef]
  11. Lin, F.-J.; Chou, P.-H.; Hung, Y.-C.; Wang, W.-M. Field-programmable gate array-based functional link radial basis function network control for permanent magnet linear synchronous motor servo drive system. IET Electr. Power Appl. 2010, 4, 357–372. [Google Scholar] [CrossRef]
  12. Muhammad, A.M.C.; John, E.F.; Muhammad, F.R.; Dan, X. Optimal, Combined Speed and Direct Thrust Control of Linear Permanent Magnet Synchronous Motors. IEEE Trans. Energy Convers. 2016, 31, 947–958. [Google Scholar] [CrossRef]
  13. Liu, X.; Zhen, S.; Sun, H.; Zhao, H. A Novel Model-based Robust Control for Position Tracking of Permanent Magnet Linear Motor. IEEE Trans. Ind. Electron. 2020, 67, 7767–7777. [Google Scholar] [CrossRef]
  14. Yuan, M.; Chen, Z.; Yao, B.; Liu, X. Fast and Accurate Motion Tracking of a Linear Motor System under Kinematic and Dynamic Constraints: An Integrated Planning and Control Approach. IEEE Trans. Control Syst. Technol. 2021, 29, 804–811. [Google Scholar] [CrossRef]
  15. Yi, S.H.; Cheng, C.S. Function-Based Controller for Linear Motor Control Systems. IEEE Trans. Ind. Electron. 2010, 57, 1096–1105. [Google Scholar] [CrossRef]
  16. Cheema, M.A.; Fletcher, J.E.; Farshadnia, M.; Xiao, D.; Rahman, M.F. Combined Speed and Direct Thrust Force Control of Linear Permanent-Magnet Synchronous Motors with Sensorless Speed Estimation Using a Sliding Mode Control with Integral Action. IEEE Trans. Ind. Electron. 2017, 64, 3489–3502. [Google Scholar] [CrossRef]
  17. Hui, Y.; Chi, R.; Huang, B.; Hou, Z. Extended State Observer-Based Data-Driven Iterative Learning Control for Permanent Magnet Linear Motor with Initial Shifts and Disturbances. IEEE Trans. Syst. Man Cybern. Syst. 2021, 51, 1881–1891. [Google Scholar] [CrossRef]
  18. Chiang, H.H.; Hsu, K.C.; Li, I.H. Optimized Adaptive Motion Control Through an SoPC Implementation for Linear Induction Motor Drives. IEEE-ASME Trans. Mechatron. 2015, 20, 348–360. [Google Scholar] [CrossRef]
  19. Chaio, S. Supervisory Interval Type-2 TSK Neural Fuzzy Network Control for Linear Microstepping Motor Drives with Uncertainty Observer. IEEE Trans. Power Electron. 2011, 26, 2049–2064. [Google Scholar] [CrossRef]
  20. Shao, K.; Zheng, J.; Huang, K.; Wang, H.; Man, Z.; Fu, M. Finite-Time Control of a Linear Motor Positioner Using Adaptive Recursive Terminal Sliding Mode. IEEE Trans. Ind. Electron. 2020, 67, 6659–6668. [Google Scholar] [CrossRef]
  21. Chen, Z.; Yao, B.; Wang, Q. Accurate Motion Control of Linear Motors with Adaptive Robust Compensation of Nonlinear Electromagnetic Field Effect. IEEE-ASME Trans. Mechatron. 2013, 18, 1122–1129. [Google Scholar] [CrossRef]
  22. Francesco, A.; Maurizio, C.; Filippo, D.I.; Marcello, P.; Antonino, S. Active Disturbance Rejection Control of Linear Induction Motor. IEEE Trans. Ind. Appl. 2017, 53, 4460–4471. [Google Scholar] [CrossRef]
  23. Bastian, C.; Serge, G.; Luca, R.; Mauro, C. Speed Control of a Multiphase Active Way Linear Motor Based on Back EMF Estimation. IEEE Trans. Ind. Electron. 2015, 62, 7299–7307. [Google Scholar] [CrossRef]
  24. Ruchao, P.; Nattapon, C.; David, G.T.; Niyom, N.; Seubsuang, K.; Prapon, J.; Pakasit, S.; Kanokvate, T. Adaptive Integral Sliding-Mode Position Control of a Coupled-Phase Linear Variable Reluctance Motor for High-Precision Applications. IEEE Trans. Ind. Appl. 2012, 48, 1353–1363. [Google Scholar] [CrossRef]
  25. Zheng, J.; Wang, H.; Man, Z.; Jin, J.; Fu, M. Robust Motion Control of a Linear Motor Positioner Using Fast Nonsingular Terminal Sliding Mode. IEEE-ASME Trans. Mechatron. 2015, 20, 1743–1752. [Google Scholar] [CrossRef]
  26. Huang, Y.-S.; Sung, C.-C. Implementation of sliding mode controller for linear synchronous motors based on direct thrust control theory. IET Contr. Theory Appl. 2010, 4, 326–338. [Google Scholar] [CrossRef]
  27. Sadighi, A.; Kim, W.J. Sensorless Control of a Novel Linear Magnetostrictive Motor. IEEE Trans. Ind. Appl. 2011, 47, 736–743. [Google Scholar] [CrossRef]
  28. Cao, R.; Jiang, N.; Lu, M. Sensorless Control of Linear Flux-switching Permanent Magnet Motor Based on Extended Kalman Filter. IEEE Trans. Ind. Electron. 2019, 67, 5971–5979. [Google Scholar] [CrossRef]
  29. Ting, C.S.; Chang, Y.N.; Shi, B.W.; Lieu, J.F. Adaptive Backstepping Control for Permanent Magnet Linear Synchronous Motor Servo Drive. IET Electr. Power Appl. 2015, 9, 265–279. [Google Scholar] [CrossRef]
  30. Yang, Y.; Chen, W. Dual stroke and phase control and system identification of linear compressor of a split-stirling cryocooler. Asian J. Control 1999, 1, 116–121. [Google Scholar] [CrossRef]
  31. Du, Z.; Zhou, Z.; Ai, W.; Chen, Y. A linear drive system for the dynamic focus module of SLS machines. Int. J. Adv. Manuf. Technol. 2007, 32, 1211–1217. [Google Scholar] [CrossRef]
  32. Pan, J.F.; Zou, Y.; Cao, G.; Cheung, N.C.; Zhang, B. High-Precision Dual-Loop Position Control of an Asymmetric Bilateral Linear Hybrid Switched Reluctance Motor. IEEE Trans. Magn. 2015, 51, 8600405. [Google Scholar] [CrossRef]
  33. Lin, Z.; Wang, J.; Howe, D. A Hybrid Current Controller for Linear Reciprocating Vapor Compressors. In Proceedings of the 2007 IEEE Industry Applications Annual Meeting, New Orleans, LA, USA, 23–27 September 2007; pp. 274–280. [Google Scholar] [CrossRef]
  34. Chun, T.W.; Ahn, J.R.; Lee, H.H.; Kim, H.G.; Nho, E.C. A novel strategy of efficiency control for a linear compressor system driven by a PWM inverter. IEEE Trans. Ind. Electron. 2008, 55, 296–301. [Google Scholar] [CrossRef]
  35. Kim, G.; Jeon, J.; Yim, C. Dynamic performance improvement of oscillating linear motors via efficient parameter identification. J. Power Electron. 2010, 10, 58–64. [Google Scholar] [CrossRef]
  36. Wang, X.; Chen, F.; Zhu, R.; Huang, X.; Sang, N.; Yang, G.; Zhang, C. A Review on Disturbance Analysis and Suppression for Permanent Magnet Linear Synchronous Motor. Actuator 2021, 10, 77. [Google Scholar] [CrossRef]
  37. Jean-Franco, L.; Nicolas, M.; Pascal, L.; Bertr, N. Analysis and Modeling of Linear-Switched Reluctance for Medical Application. Actuator 2013, 2, 27–44. [Google Scholar] [CrossRef] [Green Version]
  38. Mituhiko, A.; Hidefumi, T. Two-Degree-of-Freedom PID Controllers. Int. J. Control Autom. Syst. 2003, 1, 401–411. [Google Scholar]

Short Biography of Authors

Actuators 10 00128 i001Zongxia Jiao received the B.S. and Ph.D. degrees in mechatronics engineering from Zhejiang University, Hangzhou, China, in 1985 and 1991, respectively. From 1991 to 1993, he was as a Postdoctoral Fellow with Beihang University, where he became a Professor in 1994. He is currently the Dean of the School of Automation Science and Electrical Engineering, Beihang University. His research interests include fluid power and transmission, actuators, and sensors.
Actuators 10 00128 i002Yuan Cao received the Master degree from Yanshan University, Qinhuangdao, China in 2016. He is currently working toward his Ph.D. degree in mechanical engineering at Beihang University. His research interests include electro-hydrostatic actuators and linear motors.
Actuators 10 00128 i003Liang Yan received the Bachelor degree from North China Institute of Technology, Shanxi, China in 1995, the Master degree from Beijing Institute of Technology (BIT), Beijing, China, in 1998, and the Ph.D. degree from Nanyang Technological University (NTU), Singapore, in 2006. He was with BIT from 1998 to 2002, NTU from 2006 to 2009, and currently is a Professor at Beihang University. His research interests include robotics, actuators and sensors. He served more than ten IEEE/ASME conferences as program and publication chairman.
Actuators 10 00128 i004Xinglu Li received the Bachelor degree from Beihang University, Beijing, China in 2014. He is currently working toward his Ph.D. degree in mechanical engineering at Beihang University. His research interests include electro-hydrostatic actuators and electrohydraulic load simulators.
Actuators 10 00128 i005Lu Zhang received the master’s degree in electrical engineering from the Hebei University of Science and Technology, Shijiazhuang, China, in 2015, and the Ph.D. degree in mechatronics from Beihang University, Beijing, China, in 2020. She is currently a Postdoc with Beihang University, Beijing. Her research interests include actuators, sensors, robotics and navigation systems.
Actuators 10 00128 i006Yang Li is a research associate at Beihang University. He received his bachelor degree and Ph.D. at the School of automation science and electrical engineering in Beihang University. His research focuses on more electric aircraft flight control actuation system, intelligent mechatronic system and aircraft integrated energy management technology.
Figure 1. Cross section of PMLOSM.
Figure 1. Cross section of PMLOSM.
Actuators 10 00128 g001
Figure 2. PMLOSM diagram.
Figure 2. PMLOSM diagram.
Actuators 10 00128 g002
Figure 3. Magnitude response of PMLOSM.
Figure 3. Magnitude response of PMLOSM.
Actuators 10 00128 g003
Figure 4. Phase response of PMLOSM.
Figure 4. Phase response of PMLOSM.
Actuators 10 00128 g004
Figure 5. Relationship between input current and thrust.
Figure 5. Relationship between input current and thrust.
Actuators 10 00128 g005
Figure 6. Traditional PI control sketch of PMLOSM.
Figure 6. Traditional PI control sketch of PMLOSM.
Actuators 10 00128 g006
Figure 7. Combination of PI and feedforward control.
Figure 7. Combination of PI and feedforward control.
Actuators 10 00128 g007
Figure 8. Features of (21).
Figure 8. Features of (21).
Actuators 10 00128 g008
Figure 9. Amplitude comparison between PI and AMFC α = 0.5 .
Figure 9. Amplitude comparison between PI and AMFC α = 0.5 .
Actuators 10 00128 g009
Figure 10. Phase comparison between PI and AMFC α = 0.5 .
Figure 10. Phase comparison between PI and AMFC α = 0.5 .
Actuators 10 00128 g010
Figure 11. Amplitude comparison between PI and AMFC α = 1 .
Figure 11. Amplitude comparison between PI and AMFC α = 1 .
Actuators 10 00128 g011
Figure 12. Phase comparison between PI and AMFC α = 1 .
Figure 12. Phase comparison between PI and AMFC α = 1 .
Actuators 10 00128 g012
Figure 13. Amplitude comparison between PI and AMFC α = 1.5 .
Figure 13. Amplitude comparison between PI and AMFC α = 1.5 .
Actuators 10 00128 g013
Figure 14. Phase comparison between PI and AMFC α = 1.5 .
Figure 14. Phase comparison between PI and AMFC α = 1.5 .
Actuators 10 00128 g014
Figure 15. Amplitude of AMFC ( α = 0.8 to 1.2).
Figure 15. Amplitude of AMFC ( α = 0.8 to 1.2).
Actuators 10 00128 g015
Figure 16. Phase of AMFC ( α = 0.8 to 1.2).
Figure 16. Phase of AMFC ( α = 0.8 to 1.2).
Actuators 10 00128 g016
Figure 17. Amplitude of AMFC ( α = 0.95 to 1.05).
Figure 17. Amplitude of AMFC ( α = 0.95 to 1.05).
Actuators 10 00128 g017
Figure 18. Phase of AMFC ( α = 0.95 to 1.05).
Figure 18. Phase of AMFC ( α = 0.95 to 1.05).
Actuators 10 00128 g018
Figure 19. PMLOSM prototype.
Figure 19. PMLOSM prototype.
Actuators 10 00128 g019
Figure 20. Signal acquisition and control system.
Figure 20. Signal acquisition and control system.
Actuators 10 00128 g020
Figure 21. Amplitude at low PI.
Figure 21. Amplitude at low PI.
Actuators 10 00128 g021
Figure 22. Phase lag at low level PI.
Figure 22. Phase lag at low level PI.
Actuators 10 00128 g022
Figure 23. Amplitude at middle level PI.
Figure 23. Amplitude at middle level PI.
Actuators 10 00128 g023
Figure 24. Phase lag at middle level PI.
Figure 24. Phase lag at middle level PI.
Actuators 10 00128 g024
Figure 25. Amplitude at high level PI.
Figure 25. Amplitude at high level PI.
Actuators 10 00128 g025
Figure 26. Phase lag at high level PI.
Figure 26. Phase lag at high level PI.
Actuators 10 00128 g026
Figure 27. Amplitude of AMFC α = 0.5 to 1.
Figure 27. Amplitude of AMFC α = 0.5 to 1.
Actuators 10 00128 g027
Figure 28. Phase of AMFC α = 0.5 to 1.
Figure 28. Phase of AMFC α = 0.5 to 1.
Actuators 10 00128 g028
Figure 29. Position output of PMLOSM of PI and AMFC.
Figure 29. Position output of PMLOSM of PI and AMFC.
Actuators 10 00128 g029
Figure 30. Experiment of PID.
Figure 30. Experiment of PID.
Actuators 10 00128 g030
Figure 31. Position of AMFC.
Figure 31. Position of AMFC.
Actuators 10 00128 g031
Figure 32. Drive current of AMFC.
Figure 32. Drive current of AMFC.
Actuators 10 00128 g032
Figure 33. Amplitude–frequency characteristics of AMFC.
Figure 33. Amplitude–frequency characteristics of AMFC.
Actuators 10 00128 g033
Figure 34. Phase–frequency characteristics of AMFC.
Figure 34. Phase–frequency characteristics of AMFC.
Actuators 10 00128 g034
Figure 35. Position with load.
Figure 35. Position with load.
Actuators 10 00128 g035
Table 1. Parameters of PMLOSM.
Table 1. Parameters of PMLOSM.
SymbolQuantityValue
K e Force constant32 N/A
kSpring stiffness30,700 N/m
ξ Damping coefficient60 N s/m
mTotal mass1.35 kg
Table 2. Experiment phase lag of PI, PID and AMFC.
Table 2. Experiment phase lag of PI, PID and AMFC.
Control MethodPhase Lag/deg
AMFC2.7
PID6.4
PI18
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Jiao, Z.; Cao, Y.; Yan, L.; Li, X.; Zhang, L.; Li, Y. Advancing Motivation Feedforward Control of Permanent Magnetic Linear Oscillating Synchronous Motor for High Tracking Precision. Actuators 2021, 10, 128. https://doi.org/10.3390/act10060128

AMA Style

Jiao Z, Cao Y, Yan L, Li X, Zhang L, Li Y. Advancing Motivation Feedforward Control of Permanent Magnetic Linear Oscillating Synchronous Motor for High Tracking Precision. Actuators. 2021; 10(6):128. https://doi.org/10.3390/act10060128

Chicago/Turabian Style

Jiao, Zongxia, Yuan Cao, Liang Yan, Xinglu Li, Lu Zhang, and Yang Li. 2021. "Advancing Motivation Feedforward Control of Permanent Magnetic Linear Oscillating Synchronous Motor for High Tracking Precision" Actuators 10, no. 6: 128. https://doi.org/10.3390/act10060128

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop