Validity of Lung Ultrasound: Is an Image Worth More Than a Thousand Sounds?
Abstract
:1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Data Collection
2.2.1. Demographic Variables and Final Diagnosis
- -
- Respiratory infection, including patients with bacterial pneumonia and bronchiectasis with superinfection.
- -
- Decompensation of a previous obstructive disease, including patients with chronic obstructive pulmonary disease (COPD) and asthma.
- -
- Interstitial involvement, including patients with a discharge diagnosis of interstitial lung disease (ILD) or congestive heart failure (CHF).
2.2.2. Ultrasonographic Procedure and Variables
2.2.3. Pulmonary Auscultation Procedure and Variables
2.3. Statistical Analysis
3. Results
3.1. Sample Description
3.2. Pulmonary Auscultation and Lung Ultrasound Results
3.3. Interobserver Variability
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Laennec, R.T.H. De l’Auscultation Médiate ou Traité du Diagnostic des Maladies des Poumons et du Coeur; Brosson & Chaudé: Paris, France, 1819. [Google Scholar]
- Murphy, R.L. In Defense of the Stethoscope. Respir. Care 2008, 53, 355–369. [Google Scholar] [PubMed]
- Pasterkamp, H.; Brand, P.L.P.; Everard, M.; Garcia-Marcos, L.; Melbye, H.; Priftis, K.N. Towards the standardisation of lung sound nomenclature. Eur. Respir. J. 2016, 47, 724–732. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Markel, H. The Stethoscope and the Art of Listening. N. Engl. J. Med. 2006, 354, 551–555. [Google Scholar] [CrossRef] [PubMed]
- Lichtenstein, D.A. BLUE-protocol and FALLS-protocol: Two applications of lung ultrasound in the critically ill. Chest 2015, 147, 1659–1670. [Google Scholar] [CrossRef] [Green Version]
- Volpicelli, G.; Vanni, S.; Becattini, C.; Sferrazza Papa, G.F.; Gigli, C.; Grifoni, S.; Nazerian, P. Prediction Rule for Diagnosis of Pulmonary Embolism Enhanced by Lung and Venous Ultrasound: Making Confusion or Increasing Efficiency? Acad. Emerg. Med. 2017, 24, 498–499. [Google Scholar] [CrossRef]
- Zanobetti, M.; Scorpiniti, M.; Gigli, C.; Nazerian, P.; Vanni, S.; Innocenti, F.; Stefanone, V.T.; Savinelli, C.; Coppa, A.; Bigiarini, S.; et al. Point-of-Care Ultrasonography for Evaluation of Acute Dyspnea in the ED. Chest 2017, 151, 1295–1301. [Google Scholar] [CrossRef]
- Toma, T.P.; Volpicelli, G. Essential Image Acquisition Protocols for Thoracic Ultrasonography. Respiration 2020, 99, 231–238. [Google Scholar] [CrossRef]
- Volpicelli, G.; Elbarbary, M.; Blaivas, M.; Lichtenstein, D.A.; Mathis, G.; Kirkpatrick, A.W.; Melniker, L.; Gargani, L.; Noble, V.E.; Via, G.; et al. International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med. 2012, 38, 577–591. [Google Scholar] [CrossRef] [Green Version]
- Laursen, C.B.; Clive, A.; Hallifax, R.; Pietersen, P.I.; Asciak, R.; Davidsen, J.R.; Bhatnagar, R.; Bedawi, E.O.; Jacobsen, N.; Coleman, C.; et al. European Respiratory Society Statement on Thoracic Ultrasound. Eur. Respir. J. 2020, 57, 2001519. [Google Scholar] [CrossRef]
- Lichtenstein, D.A.; Mezière, G.A. Relevance of lung ultrasound in the diagnosis of acute respiratory failure: The BLUE protocol. Chest 2008, 134, 117–125. [Google Scholar] [CrossRef] [Green Version]
- Loudon, R.; Murphy, R.L. Lung sounds. Am. Rev. Respir. Dis. 1984, 130, 663–673. [Google Scholar] [PubMed]
- Landis, J.R.; Koch, G.G. The Measurement of Observer Agreement for Categorical Data. Biometrics 1977, 33, 159–174. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- De Lucas Ramos, P.; Rodríguez-Moro, J.M. Libro Blanco de La Neumología en España; Respira, Fundación Española del Pulmón; SEPAR: Madrid, Spain, 2015. [Google Scholar]
- Cottin, V.; Cordier, J.-F. Velcro crackles: The key for early diagnosis of idiopathic pulmonary fibrosis? Eur. Respir. J. 2012, 40, 519–521. [Google Scholar] [CrossRef] [Green Version]
- Lovrenski, J.; Petrović, S.; Balj-Barbir, S.; Jokić, R.; Vilotijević-Dautović, G. Stethoscope vs. ultrasound probe—Which is more reliable in children with suspected pneumonia? Acta Med. Acad. 2016, 45, 39–50. [Google Scholar] [CrossRef]
- From the Global Strategy for the Diagnosis, Management and Prevention of COPD, Global Initiative for Chronic Obstructive Lung Disease (GOLD). 2021. Available online: https://goldcopd.org (accessed on 17 January 2021).
- Global Initiative for Asthma. Global Strategy for Asthma Management and Prevention NHLBI/WHO Workshop Report; National Institutes of Health, National Heart, Lung, and Blood Institute: Bethesda, MD, USA, 2020; Available online: https://ginasthma.org (accessed on 20 December 2020).
- Lichtenstein, D.; Goldstein, I.; Mourgeon, E.; Cluzel, P.; Grenier, P.; Rouby, J.-J. Comparative Diagnostic Performances of Auscultation, Chest Radiography, and Lung Ultrasonography in Acute Respiratory Distress Syndrome. Anesthesiology 2004, 100, 9–15. [Google Scholar] [CrossRef]
- Mozzini, C.; Pasini, A.M.F.; Garbin, U.; Cominacini, L. Lung ultrasound in internal medicine: Training and clinical practice. Crit Ultrasound J. 2016, 8, 1–7. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Gullett, J.; Donnelly, J.P.; Sinert, R.; Hosek, B.; Fuller, D.; Hill, H.; Feldman, I.; Galetto, G.; Auster, M.; Hoffmann, B.; et al. Interobserver agreement in the evaluation of B-lines using bedside ultrasound. J. Crit. Care 2015, 30, 1395–1399. [Google Scholar] [CrossRef] [PubMed]
- Biagi, C.; Pierantoni, L.; Baldazzi, M.; Greco, L.; Dormi, A.; Dondi, A.; Faldella, G.; Lanari, M. Lung ultrasound for the diagnosis of pneumonia in children with acute bronchiolitis. BMC Pulm. Med. 2018, 18, 191. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Smyllie, H.C.; Blendis, L.M.; Armitage, P. Observer disagreement in physical signs of the respiratory system. Lancet 1965, 2, 412–413. [Google Scholar] [CrossRef]
- Spiteri, M.A.; Cook, D.G.; Clarke, S.W. Reliability of eliciting physical signs in examination of the chest. Lancet 1988, 1, 873–875. [Google Scholar] [CrossRef]
- Brooks, D.; Thomas, J. Interrater Reliability of Auscultation of Breath Sounds Among Physical Therapists. Phys. Ther. 1995, 75, 1082–1088. [Google Scholar] [CrossRef] [PubMed]
- Bohadana, A.; Izbicki, G.; Kraman, S.S. Fundamentals of Lung Auscultation. N. Engl. J. Med. 2014, 370, 744–751. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Aviles-Solis, J.C.; Vanbelle, S.; Halvorsen, P.A.; Francis, N.; Cals, J.W.L.; Andreeva, E.A.; Marques, A.; Piirilä, P.; Pasterkamp, H.; Melbye, H. International perception of lung sounds: A comparison of classification across some European borders. BMJ Open Respir. Res. 2017, 4, e000250. [Google Scholar] [CrossRef] [PubMed]
- Holleman, D.R. Does the Clinical Examination Predict Airflow Limitation? JAMA 1995, 273, 313. [Google Scholar] [CrossRef]
Discharge Diagnosis | LUS Findings * | LA Findings * |
---|---|---|
Respiratory infection (n = 78) | A-pattern 3 (3.8%) Pathological B-lines 66 (84.6%)
Pleural effusion 21 (26.9%) 9 (11.5%) >3 intercostal spaces | Rhonchi 28 (35.9%) Crackles
Normal 13 (45.5%) |
Underlying obstructive disease (n = 22) | A-pattern 14 (63.6%) Pathological B-lines 7 (31.8%)
Pleural effusion 1 (4.5%) <1 intercostal space | Rhonchi 5 (22.7%) Crackles
Normal 10 (45.4%) |
Interstitial involvement (n= 15)
| A-pattern 0 Pathological B-lines 8 (100%)
Pleural thickening 5 (62.5%) Consolidation 0 Pleural effusion 0 | Rhonchi 1 (12.5%) Crackles 6 (75%)
Normal 0 |
| A-pattern 0 Pathological B-lines 7 (100%)
Hypoechoic artifacts effacing the pleura 0 Pleural thickening 0 Pleural effusion 3 (42.9%) Only 1 >3 intercostal spaces | Rhonchi 2 (28.6%) Crackles 4 (57.1%)
Normal 0 |
Discharge Diagnosis | LUS | LA | p | LUS and/or LA | |
---|---|---|---|---|---|
Focal B-Lines and/or Consolidation | Rhonchi and/or Crackles and/or Wheezes | ||||
Respiratory infection (n = 78) | Sensitivity | 93.59% | 77.02% | p = 0.00 | 95.95% |
Specificity | 37.88% | 27.77% | p = 0.58 | 50% | |
Diagnostic accuracy | 76.65% | 60.90% | p = 0.08 | ||
A-pattern | Rhonchi and/or crackles and/or wheezes | p | LUS and/or LA | ||
Underlying obstructive disease (n = 22) | Sensitivity | 63.63% | 52.38% | p = 0.72 | 76.19% |
Specificity | 95.60% | 19.10% | p = 0.00 | 100% | |
Diagnostic accuracy | 89.51% | 25.40% | p = 0.00 | ||
Diffuse B-lines | Crackles | p | LUS and/or LA | ||
Interstitial involvement (n = 15) | Sensitivity | 86.66% | 66.67% | p = 0.45 | 100% |
Specificity | 73% | 76.04% | p = 0.57 | 88.54% | |
Diagnostic accuracy | 74.75% | 74.77% | p = 0.31 |
Lung Ultrasound | |
---|---|
A-pattern | ᴋ = 0.71 (95% CI: 0.70–0.74) |
Pathological B-lines | ᴋ = 0.73 (95% CI: 0.73–0.75) |
Focal B-lines | ᴋ = 0.73 (95% CI: 0.72–0.75) |
Diffuse B-lines | ᴋ = 0.81 (95% CI: 0.81–0.83) |
Consolidation | ᴋ = 0.94 (95% CI: 0.93–0.95) |
Pleural effusion | ᴋ = 0.89 (95% CI: 0.88–0.90) |
Lung Auscultation | |
Wheezes | ᴋ = 0.63 (95% CI: 0.61–0.65) |
Fine crackles | ᴋ = 0.68 (95% CI: 0.66–0.70) |
Coarse crackles | ᴋ = 0.18 (95% CI: 0.16–0.20) |
Rhonchi | ᴋ = 0.38 (95% CI: 0.36–0.40) |
Normal | ᴋ = 0.29 (95% CI: 0.27–0.31) |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Ramos-Hernández, C.; Botana-Rial, M.; Núñez-Fernández, M.; Lojo-Rodríguez, I.; Mouronte-Roibas, C.; Salgado-Barreira, Á.; Ruano-Raviña, A.; Fernández-Villar, A. Validity of Lung Ultrasound: Is an Image Worth More Than a Thousand Sounds? J. Clin. Med. 2021, 10, 2292. https://doi.org/10.3390/jcm10112292
Ramos-Hernández C, Botana-Rial M, Núñez-Fernández M, Lojo-Rodríguez I, Mouronte-Roibas C, Salgado-Barreira Á, Ruano-Raviña A, Fernández-Villar A. Validity of Lung Ultrasound: Is an Image Worth More Than a Thousand Sounds? Journal of Clinical Medicine. 2021; 10(11):2292. https://doi.org/10.3390/jcm10112292
Chicago/Turabian StyleRamos-Hernández, Cristina, Maribel Botana-Rial, Marta Núñez-Fernández, Irene Lojo-Rodríguez, Cecilia Mouronte-Roibas, Ángel Salgado-Barreira, Alberto Ruano-Raviña, and Alberto Fernández-Villar. 2021. "Validity of Lung Ultrasound: Is an Image Worth More Than a Thousand Sounds?" Journal of Clinical Medicine 10, no. 11: 2292. https://doi.org/10.3390/jcm10112292
APA StyleRamos-Hernández, C., Botana-Rial, M., Núñez-Fernández, M., Lojo-Rodríguez, I., Mouronte-Roibas, C., Salgado-Barreira, Á., Ruano-Raviña, A., & Fernández-Villar, A. (2021). Validity of Lung Ultrasound: Is an Image Worth More Than a Thousand Sounds? Journal of Clinical Medicine, 10(11), 2292. https://doi.org/10.3390/jcm10112292