Next Article in Journal
The Correlation between Chronic Endometritis and Tubal-Factor Infertility
Previous Article in Journal
Upregulation of miRNA-200c during Disease Progression in COVID-19 Patients
Previous Article in Special Issue
Unmet Needs in TAVR: Conduction Disturbances and Management of Coronary Artery Disease
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Editorial

Device Selection for Transcatheter Aortic Valve Implantation

ACTION Study Group, INSERM UMRS 1166 Institut de Cardiologie, Sorbonne Université, Pitié Salpêtrière (APHP), 75013 Paris, France
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2023, 12(1), 284; https://doi.org/10.3390/jcm12010284
Submission received: 20 December 2022 / Accepted: 23 December 2022 / Published: 29 December 2022
(This article belongs to the Special Issue Aortic Valve Replacement: Ongoing Issues and Challenges)
Twenty years after the first implantation by Alain Cribier and his team, transcatheter aortic valve implantation (TAVI) has demonstrated its efficacy and safety in patients with symptomatic severe aortic stenosis with high, intermediate, and even low surgical risk. Consequently, its indications have expanded widely over the years, with the improvement of structural devices, operator’s experience, procedural techniques, and post-procedural management [1,2].
Most devices currently available are either balloon-expandable or self-expanding transcatheter heart valves (THV). A recent meta-analysis of randomized control trials and a prospective international observational study suggested that newer generation devices such as Sapien 3 for the Edward Sapien™ (Edward Lifesciences, Irvine, CA, USA) or the Evolut R or Evolut Pro for the Medtronik CoreValve™ (Minneapolis, MN, USA) were associated with a reduction of all-cause mortality, and major cerebro-cardiovascular events when compared to surgical aortic valve replacement (SAVR) [3,4]. There are, however, only limited conclusive data on the respective performance of these two device types. In fact, both types were recently compared, after propensity score matching, among 12,381 patients undergoing transfemoral TAVI and included in the international Cerebrovascular Events in Patients Undergoing Transcatheter Aortic Valve Implantation (CENTER) collaboration [5]. No significant differences were reported for “hard” clinical endpoints, such as death or stroke—neither at thirty days, nor one year.
Compared to SAVR, TAVI has been traditionally associated with a higher risk of aortic regurgitation due to paravalvular leakage or permanent pacemaker implantation (PPI) [3,4]. The presence of moderate or severe paravalvular leak following TAVI remains a source of concern as it was an independent risk factor for mortality in the French national FRANCE TAVI registry, with six and a half years of follow-up [6].
The recent long-term study by Tamm et al. reported higher mean transaortic gradients but lower paravalvular leak with Sapien 3 prosthesis when compared to the Evolut R, although this did not result in any significant difference concerning five-year mortality, which was similar between the two types of devices [7]. The recent Evolut vs. Myval for the Treatment of Patients with Severe Aortic Valve Stenosis (EVAL) registry reported promising results on the safety and efficacy of the new Myval balloon-expandable THV, which provided comparable performance to the Evolut R self-expanding device, with a lower rate of PPI and a moderate to severe paravalvular leak six months after the procedure [8]. The self-expanding Acurate neo™ (Boston scientific, Malborough, Massachusetts, USA) and Portico™ (Abbott, Chicago, IL, USA) THV were compared in a large multicenter center observational study with propensity-score matching, which did not report significant differences in terms of grade II or more paravalvular leakage (4.8% vs. 3.5%, respectively, p = 0.546) [9].
Device selection remains a challenge in patients with small aortic annuli, as it increases the risk of prosthesis-patient mismatch (PPM) which is associated with poorer outcomes, or in cases of severely calcified aortic valves which can result in a higher risk of paravalvular leakage, PPI or even aortic annulus rupture. Balloon-expandable Sapien 3 valves have been associated with significantly higher rates of PPM in comparison with self-expanding Evolut Pro or Accurate Neo valves, while mild to severe paravalvular leaks may be more frequent with the latter [10]. Similar results were reported in an echo Doppler comparative study in patients with small aortic annuli, demonstrating improved hemodynamic performances with self-expanding devices when compared to balloon-expandable valves [11]. It should be noted, however, that these features did not result in differences in terms of clinical outcomes, although the relatively limited sample size and follow-up duration prevent any definitive conclusions. In the case of patients with severely calcified aortic valve stenosis, self-expanding new-generation Evolut Pro devices have been associated, yet again, with lower rates of moderate and severe PPM compared to balloon-expandable Sapien 3, without significant differences in terms of paravalvular leakage or PPI implantation [12].
Uncertainty remains about the selection of the optimal device in patients with severe aortic stenosis undergoing TAVR. Larger observational studies and randomized controlled trials with adequate statistical power and long-term follow-up are warranted to further evaluate this issue.

Author Contributions

C.G. wrote the first draft of the manuscript and P.G. made critical edits. All authors have read and agreed to the published version of the manuscript.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Mesnier, J.; Panagides, V.; Nuche, J.; Rodés-Cabau, J. Evolving Indications of Transcatheter Aortic Valve Replacement-Where Are We Now, and Where Are We Going. J. Clin. Med. 2022, 11, 3090. [Google Scholar] [CrossRef] [PubMed]
  2. Granger, C.; Guedeney, P.; Collet, J.-P. Antithrombotic Therapy Following Transcatheter Aortic Valve Replacement. J. Clin. Med. 2022, 11, 2190. [Google Scholar] [CrossRef]
  3. Dogosh, A.A.; Adawi, A.; El Nasasra, A.; Cafri, C.; Barrett, O.; Tsaban, G.; Barashi, R.; Koifman, E. Comparison of Transcatheter Aortic Valve Implantation Devices in Aortic Stenosis: A Network Meta-Analysis of 42,105 Patients. J. Clin. Med. 2022, 11, 5299. [Google Scholar] [CrossRef] [PubMed]
  4. Rosato, S.; Biancari, F.; D’Errigo, P.; Barbanti, M.; Tarantini, G.; Bedogni, F.; Ranucci, M.; Costa, G.; Juvonen, T.; Ussia, G.P.; et al. One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices. J. Clin. Med. 2021, 10, 3703. [Google Scholar] [CrossRef] [PubMed]
  5. van Nieuwkerk, A.C.; Santos, R.B.; Andraka, L.; Tchetche, D.; de Brito, F.S.; Barbanti, M.; Kornowski, R.; Latib, A.; D’Onofrio, A.; Ribichini, F.; et al. Balloon-Expandable versus Self-Expandable Valves in Transcatheter Aortic Valve Implantation: Complications and Outcomes from a Large International Patient Cohort. J. Clin. Med. 2021, 10, 4005. [Google Scholar] [CrossRef] [PubMed]
  6. Deharo, P.; Leroux, L.; Theron, A.; Ferrara, J.; Vaillier, A.; Jaussaud, N.; Porto, A.; Morera, P.; Gariboldi, V.; Iung, B.; et al. Long-Term Prognosis Value of Paravalvular Leak and Patient–Prosthesis Mismatch Following Transcatheter Aortic Valve Implantation: Insight from the France-TAVI Registry. J. Clin. Med. 2022, 11, 6117. [Google Scholar] [CrossRef] [PubMed]
  7. Tamm, A.R.; Geyer, M.; Kreidel, F.; Dausmann, L.; Jablonski, C.; Hahad, O.; Schulz, E.; Münzel, T.; Von Bardeleben, R.S. Long-Term Outcome with New Generation Prostheses in Patients Undergoing Transcatheter Aortic Valve Replacement. J. Clin. Med. 2021, 10, 3102. [Google Scholar] [CrossRef] [PubMed]
  8. Barki, M.; Ielasi, A.; Buono, A.; Maliandi, G.; Pellicano, M.; Bande, M.; Casilli, F.; Messina, F.; Uccello, G.; Briguglia, D.; et al. Clinical Comparison of a Novel Balloon-Expandable Versus a Self-Expanding Transcatheter Heart Valve for the Treatment of Patients with Severe Aortic Valve Stenosis: The EVAL Registry. J. Clin. Med. 2022, 11, 959. [Google Scholar] [CrossRef] [PubMed]
  9. Blumenstein, J.; Eckel, C.; Husser, O.; Kim, W.-K.; Renker, M.; Choi, Y.-H.; Hamm, C.W.; Al-Terki, H.; Sötemann, D.; Körbi, L.; et al. Multi-Center Comparison of Two Self-Expanding Transcatheter Heart Valves: A Propensity Matched Analysis. J. Clin. Med. 2022, 11, 4228. [Google Scholar] [CrossRef] [PubMed]
  10. Ferrara, J.; Theron, A.; Porto, A.; Morera, P.; Luporsi, P.; Jaussaud, N.; Gariboldi, V.; Collart, F.; Cuisset, T.; Deharo, P. Prosthesis-Patient Mismatch in Small Aortic Annuli: Self-Expandable vs. Balloon-Expandable Transcatheter Aortic Valve Replacement. J. Clin. Med. 2022, 11, 1959. [Google Scholar] [CrossRef] [PubMed]
  11. Kanso, M.; Kibler, M.; Hess, S.; Rischner, J.; Plastaras, P.; Kindo, M.; Hoang, M.; De Poli, F.; Leddet, P.; Petit, H.; et al. Effective Orifice Area of Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Prostheses: An Echo Doppler Comparative Study. J. Clin. Med. 2021, 10, 186. [Google Scholar] [CrossRef] [PubMed]
  12. Potratz, M.; Mohemed, K.; Omran, H.; Gortamashvili, L.; Friedrichs, K.P.; Scholtz, W.; Scholtz, S.; Rudolph, V.; Piper, C.; Gilis-Januszewski, T.; et al. Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis. J. Clin. Med. 2022, 11, 4570. [Google Scholar] [CrossRef] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Granger, C.; Guedeney, P. Device Selection for Transcatheter Aortic Valve Implantation. J. Clin. Med. 2023, 12, 284. https://doi.org/10.3390/jcm12010284

AMA Style

Granger C, Guedeney P. Device Selection for Transcatheter Aortic Valve Implantation. Journal of Clinical Medicine. 2023; 12(1):284. https://doi.org/10.3390/jcm12010284

Chicago/Turabian Style

Granger, Camille, and Paul Guedeney. 2023. "Device Selection for Transcatheter Aortic Valve Implantation" Journal of Clinical Medicine 12, no. 1: 284. https://doi.org/10.3390/jcm12010284

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop