A Randomized Study of Rigid Video Stylet versus Macintosh Laryngoscope for Double-Lumen Endobronchial Tube Intubation Assistance in Thoracoscopic Pulmonary Surgery
Abstract
:1. Introduction
2. Materials and Methods
2.1. Outcome Variables
2.2. Sample Size
2.3. Statistical Analysis
3. Results
3.1. Demographic and Perioperative Data
3.2. Intubation Time and Success Rate
3.3. Intubation Influences
4. Discussion
Limitations of the Study
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- El-Tahan, M.R.; Khidr, A.M.; Gaarour, I.S.; Alshadwi, S.A.; Alghamdi, T.M.; Al‘ghamdi, A. A Comparison of 3 Videolaryngoscopes for Double-Lumen Tube Intubation in Humans by Users with Mixed Experience: A Randomized Controlled Study. J. Cardiothorac. Vasc. Anesth. 2018, 32, 277–286. [Google Scholar] [CrossRef]
- Brodsky, J.B. Lung separation and the difficult airway. Br. J. Anaesth. 2009, 103, i66–i75. [Google Scholar] [CrossRef] [Green Version]
- Abdelgadir, I.S.; Phillips, R.S.; Singh, D.; Moncreiff, M.P.; Lumsden, J.L. Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in children (excluding neonates). Cochrane Database Syst. Rev. 2017, 5, Cd011413. [Google Scholar] [CrossRef] [PubMed]
- Chen, P.T.; Ting, C.K.; Lee, M.Y.; Cheng, H.W.; Chan, K.H.; Chang, W.K. A randomised trial comparing real-time double-lumen endobronchial tube placement with the Disposcope((R)) with conventional blind placement. Anaesthesia 2017, 72, 1097–1106. [Google Scholar] [CrossRef] [Green Version]
- Yang, M.; Kim, J.A.; Ahn, H.J.; Choi, J.W.; Kim, D.K.; Cho, E.A. Double-lumen tube tracheal intubation using a rigid video-stylet: A randomized controlled comparison with the Macintosh laryngoscope. Br. J. Anaesth. 2013, 111, 990–995. [Google Scholar] [CrossRef] [Green Version]
- Hsu, H.T.; Chou, S.H.; Chen, C.L.; Tseng, K.-Y.; Kuo, Y.-W.; Chen, M.-K.; Cheng, K.-I. Left endobronchial intubation with a double-lumen tube using direct laryngoscopy or the Trachway(R) video stylet. Anaesthesia 2013, 68, 851–855. [Google Scholar] [CrossRef]
- Szarpak, L.; Kurowski, A.; Czyzewski, L.; Rodríguez-Núñez, A. Video rigid flexing laryngoscope (RIFL) vs Miller laryngoscope for tracheal intubation during pediatric resuscitation by paramedics: A simulation study. Am. J. Emerg. Med. 2015, 33, 1019–1024. [Google Scholar] [CrossRef]
- Szarpak, L.; Truszewski, Z.; Czyzewski, L.; Kurowski, A.; Bogdanski, L.; Zasko, P. Child endotracheal intubation with a Clarus Levitan fiberoptic stylet vs Macintosh laryngoscope during resuscitation performed by paramedics: A randomized crossover manikin trial. Am. J. Emerg. Med. 2015, 33, 1547–1551. [Google Scholar] [CrossRef] [PubMed]
- Chang, J.E.; Kim, H.; Min, S.W.; Lee, J.-M.; Ryu, J.-H.; Yoon, S.; Hwang, J.-Y. A Randomized Controlled Trial Comparing the Utility of Lighted Stylet and GlideScope for Double-Lumen Endobronchial Intubation. J. Cardiothorac. Vasc. Anesth. 2018, 32, 290–296. [Google Scholar] [CrossRef] [PubMed]
- Park, S.H.; Han, S.H.; Do, S.H.; Kim, J.W.; Rhee, K.Y.; Kim, J.H. Prophylactic dexamethasone decreases the incidence of sore throat and hoarseness after tracheal extubation with a double-lumen endobronchial tube. Anesth. Analg. 2008, 107, 1814–1818. [Google Scholar] [CrossRef]
- Karzai, W.; Schwarzkopf, K. Hypoxemia during one-lung ventilation: Prediction, prevention, and treatment. Anesthesiology 2009, 110, 1402–1411. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Lange, M.; Frommer, M.; Redel, A.; Trautner, H.; Hampel, J.; Kranke, P.; Kehl, F.; Scholtz, L.U.; Roewer, N. Comparison of the Glidescope and Airtraq optical laryngoscopes in patients undergoing direct microlaryngoscopy. Anaesthesia 2009, 64, 323–328. [Google Scholar] [CrossRef]
- Ander, F.; Magnuson, A.; Berggren, L.; Ahlstrand, R.; De Leon, A. Time-to-intubation in obese patients. A randomized study comparing direct laryngoscopy and videolaryngoscopy in experienced anesthetists. Minerva Anestesiol. 2017, 83, 906–913. [Google Scholar] [CrossRef]
- Karczewska, K.; Bialka, S.; Smereka, J.; Cyran, M.; Nowak-Starz, G.; Chmielewski, J.; Pruc, M.; Wieczorek, P.; Peacock, F.W.; Ladny, J.R.; et al. Efficacy and Safety of Video-Laryngoscopy versus Direct Laryngoscopy for Double-Lumen Endotracheal Intubation: A Systematic Review and Meta-Analysis. J. Clin. Med. 2021, 10, 5524. [Google Scholar] [CrossRef] [PubMed]
- Palaczynski, P.; Misiolek, H.; Bialka, S.; Owczarek, A.J.; Gola, W.; Szarpak, Ł.; Smereka, J. A randomized comparison between the VivaSight double-lumen tube and standard double-lumen tube intubation in thoracic surgery patients. J. Thorac. Dis. 2022, 14, 3903–3914. [Google Scholar] [CrossRef]
- Szarpak, L.; Kurowski, A.; Zaśko, P.; Karczewska, K.; Czyzewski, L.; Bogdanski, L.; Adamczyk, P.; Truszewski, Z. Double-lumen tube tracheal intubation in a manikin model using the VivaSight Double Lumen: A randomized controlled comparison with the Macintosh laryngoscope. Am. J. Emerg. Med. 2016, 34, 103–104. [Google Scholar] [CrossRef] [PubMed]
- Seo, H.; Lee, G.; Ha, S.I.; Song, J.G. An awake double lumen endotracheal tube intubation using the Clarus Video System in a patient with an epiglottic cyst: A case report. Korean J. Anesthesiol. 2014, 66, 157–159. [Google Scholar] [CrossRef] [Green Version]
- Kirkegaard-Nielsen, H.; Caldwell, J.E.; Berry, P.D. Rapid tracheal intubation with rocuronium: A probability approach to determining dose. Anesthesiology 1999, 91, 131–136. [Google Scholar] [CrossRef] [Green Version]
- Driver, B.E.; Prekker, M.E.; Klein, L.R.; Reardon, R.F.; Miner, J.R.; Fagerstrom, E.T.; Cleghorn, M.R.; McGill, J.W.; Cole, J. Effect of Use of a Bougie vs Endotracheal Tube and Stylet on First-Attempt Intubation Success Among Patients With Difficult Airways Undergoing Emergency Intubation: A Randomized Clinical Trial. JAMA 2018, 319, 2179–2189. [Google Scholar] [CrossRef] [Green Version]
- Palvia, V.; Gonzalez, A.J.H.; Vigh, R.S.; Anasti, J.N. A Randomized Controlled Trial Comparing Laparoscopic Lens Defogging Techniques through Simulation Model. Gynecol. Minim. Invasive. Ther. 2018, 7, 156–160. [Google Scholar] [CrossRef]
- Roth, D.; Pace, N.L.; Lee, A.; Hovhannisyan, K.; Warenits, A.-M.; Arrich, J.; Herkner, H. Airway physical examination tests for detection of difficult airway management in apparently normal adult patients. Cochrane Database Syst. Rev. 2018, 5, Cd008874. [Google Scholar] [CrossRef] [PubMed]
- Kaji, A.H.; Shover, C.; Lee, J.; Yee, L.; Pallin, D.J.; April, M.D.; Carlson, J.N.; Mph, A.F.; Brown, C.A. Video Versus Direct and Augmented Direct Laryngoscopy in Pediatric Tracheal Intubations. Acad. Emerg. Med. 2020, 27, 394–402. [Google Scholar] [CrossRef]
- Kitagawa, H.; Yamazaki, T.; Imashuku, Y. The “jaw thrust” maneuver rather than the “BURP” maneuver improves the glottic view for Pentax-AWS assisted tracheal intubation in a patient with a laryngeal aperture. Can. J. Anaesth. 2010, 57, 517–518. [Google Scholar] [CrossRef] [Green Version]
- Aoyama, K.; Takenaka, I.; Nagaoka, E.; Kadoya, T. Jaw thrust maneuver for endotracheal intubation using a fiberoptic stylet. Anesth. Analg. 2000, 90, 1457–1458. [Google Scholar] [CrossRef] [PubMed]
- Biro, P.; Seifert, B.; Pasch, T. Complaints of sore throat after tracheal intubation: A prospective evaluation. Eur. J. Anaesthesiol. 2005, 22, 307–311. [Google Scholar] [CrossRef] [Green Version]
- El-Boghdadly, K.; Bailey, C.R.; Wiles, M.D. Postoperative sore throat: A systematic review. Anaesthesia 2016, 71, 706–717. [Google Scholar] [CrossRef]
- Lewis, S.R.; Butler, A.R.; Parker, J.; Cook, T.M.; Smith, A.F. Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation. Cochrane Database Syst. Rev. 2016, 11, Cd011136. [Google Scholar] [CrossRef]
- Mencke, T.; Echternach, M.; Kleinschmidt, S.; Lux, P.; Barth, V.; Plinkert, P.K.; Fuchs-Buder, T. Laryngeal morbidity and quality of tracheal intubation: A randomized controlled trial. Anesthesiology 2003, 98, 1049–1056. [Google Scholar] [CrossRef]
- Kamimura, Y.; Nakanishi, T.; Sato, A.B.; Osaga, S.; Kako, E.; Sobue, K. Effects of the anesthesiologist‘s experience on postoperative hoarseness after double-lumen endotracheal tube intubation: A single-center propensity score-matched analysis. BMC Anesthesiol. 2020, 20, 278. [Google Scholar] [CrossRef] [PubMed]
- Jones, M.W.; Catling, S.; Evans, E.; Green, D.H.; Green, J.R. Hoarseness after tracheal intubation. Anaesthesia 1992, 47, 213–216. [Google Scholar] [CrossRef]
- Ezri, T.; Warters, R.D.; Szmuk, P.; Saad-Eddin, H.; Geva, D.; Katz, J.; Hagberg, C. The incidence of class “zero” airway and the impact of Mallampati score, age, sex, and body mass index on prediction of laryngoscopy grade. Anesth. Analg. 2001, 93, 1073–1075. [Google Scholar] [CrossRef] [PubMed]
- Turkstra, T.P.; Craen, R.A.; Pelz, D.M.; Gelb, A.W. Cervical spine motion: A fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope. Anesth. Analg. 2005, 101, 910–915. [Google Scholar] [CrossRef] [PubMed]
Parameter | ML (n = 65) | RVS (n = 65) |
---|---|---|
Sex (M/F) | 31/34 | 28/37 |
Age (yr) | 58.78 ± 9.52 | 57.23 ± 11.18 |
Height (cm) | 165 ± 7.0 | 164 ± 7.4 |
Weight (kg) | 66.2 ± 11.10 | 64.38 ± 10.78 |
Modified Mallampati class(I/II) | 42/23 | 47/18 |
Side of the operation (Left/Right) | 26/39 | 31/34 |
DLT duration (min) | 93.40 ± 24.83 | 90.20 ± 27.89 |
ASA physical status (I/II/III/IV) | 20/36/9/0 | 24/34/7/0 |
Variables | ML (n = 65) | RVS (n = 65) | Mean Difference (95%CI) | p Value |
---|---|---|---|---|
Intubation time(s) | 39.62 ± 6.54 (n = 63) | 30.82 ± 10.61 (n = 61) | 8.80 (5.65–11.95) | <0.001 |
First attempt intubation success rate | 62 (95.16%) | 54 (83.08%) | (2.10–2.70%) | 0.048 |
Overall intubation success rate | 63 (96.92%) | 61 (93.85%) | (42.50–44.50%) | 0.676 |
Variables | ML (n = 65) | RVS (n = 65) | 95%CI | p Value |
---|---|---|---|---|
Delta MAP | 10 (n = 65) | 10 (n = 65) | (0.699–0.717) | 0.707 |
POST 1 h (no/mild/medium/severe) | 1 1/35/23/2 | 1 9/33/15/3 | (0.016–0.021) | 0.021 |
POST 24 h (no/mild/medium/severe) | 0 42/19/0/0 | 0 49/10/1/0 | (0.085–0.096) | 0.077 |
PH 1 h (0/1/2/3) | 1 29/15/13/4 | 0 31/11/13/5 | (0.655–0.673) | 0.660 |
PH 24 h (0/1/2/3) | 0 58/0/3/0 | 0 55/1/1/3 | (0.303–0.321) | 0.376 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Gu, Y.; Zhou, Q.; Zhou, H.; Liu, M.; Feng, D.; Wei, J.; Min, K.; Zhu, W.; Chen, Y.; Lv, X. A Randomized Study of Rigid Video Stylet versus Macintosh Laryngoscope for Double-Lumen Endobronchial Tube Intubation Assistance in Thoracoscopic Pulmonary Surgery. J. Clin. Med. 2023, 12, 540. https://doi.org/10.3390/jcm12020540
Gu Y, Zhou Q, Zhou H, Liu M, Feng D, Wei J, Min K, Zhu W, Chen Y, Lv X. A Randomized Study of Rigid Video Stylet versus Macintosh Laryngoscope for Double-Lumen Endobronchial Tube Intubation Assistance in Thoracoscopic Pulmonary Surgery. Journal of Clinical Medicine. 2023; 12(2):540. https://doi.org/10.3390/jcm12020540
Chicago/Turabian StyleGu, Yang, Qing Zhou, Huanping Zhou, Meiyun Liu, Di Feng, Juan Wei, Keting Min, Wanli Zhu, Yuanli Chen, and Xin Lv. 2023. "A Randomized Study of Rigid Video Stylet versus Macintosh Laryngoscope for Double-Lumen Endobronchial Tube Intubation Assistance in Thoracoscopic Pulmonary Surgery" Journal of Clinical Medicine 12, no. 2: 540. https://doi.org/10.3390/jcm12020540
APA StyleGu, Y., Zhou, Q., Zhou, H., Liu, M., Feng, D., Wei, J., Min, K., Zhu, W., Chen, Y., & Lv, X. (2023). A Randomized Study of Rigid Video Stylet versus Macintosh Laryngoscope for Double-Lumen Endobronchial Tube Intubation Assistance in Thoracoscopic Pulmonary Surgery. Journal of Clinical Medicine, 12(2), 540. https://doi.org/10.3390/jcm12020540