Next Article in Journal
Electrochemical Determination of Morphine in Urine Samples by Tailoring FeWO4/CPE Sensor
Next Article in Special Issue
Intensity Interrogation-Based High-Sensitivity Surface Plasmon Resonance Imaging Biosensor for Apoptosis Detection in Cancer
Previous Article in Journal
One-Pot Preparation of Imidazole-Ring-Modified Graphitic Carbon Nitride Nanozymes for Colorimetric Glucose Detection
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Prostate-Specific Antigen Monitoring Using Nano Zinc(II) Metal–Organic Framework-Based Optical Biosensor

1
Department of Nanomaterials and Nanotechnology, Central Metallurgical R & D Institute, Cairo 11421, Egypt
2
Department of Inorganic Chemistry, National Research Centre, Cairo 12622, Egypt
3
Department of Biochemistry, Egypt Centre for Research and Regenerative Medicine, Cairo 11887, Egypt
4
Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
*
Authors to whom correspondence should be addressed.
Biosensors 2022, 12(11), 931; https://doi.org/10.3390/bios12110931
Submission received: 4 October 2022 / Revised: 21 October 2022 / Accepted: 22 October 2022 / Published: 27 October 2022
(This article belongs to the Special Issue Nano Biosensor and Its Application for In Vivo/Vitro Diagnosis)

Abstract

:
Background: The prostate-specific antigen (PSA) is an important cancer biomarker that is commonly utilized in the diagnosis of prostate cancer. The development of a PSA determination technique that is rapid, simple, and inexpensive, in addition to highly accurate, sensitive, and selective, remains a formidable obstacle. Methods: In this study, we developed a practical biosensor based on Zn(II) metal–organic framework nanoparticles (Zn-MOFs-NPs). Many spectroscopic and microanalytical tools are used to determine the structure, morphology, and physicochemical properties of the prepared MOF. Results: According to the results, Zn-MOFs-NPs are sensitive to PSA, selective to an extremely greater extent, and stable in terms of chemical composition. Furthermore, the Zn-MOFs-NPs did not exhibit any interferences from other common analytes that might cause interference. The detection limit for PSA was calculated and was 0.145 fg/mL throughout a wide linear concentration range (0.1 fg/mL–20 pg/mL). Conclusions: Zn-MOFs-NPs were successfully used as a growing biosensor for the monitoring and measurement of PSA in biological real samples.

Graphical Abstract

1. Introduction

In males, the prostate gland is a common site for the development of prostate cancer, one of the most rapidly progressing forms of malignant tumors [1,2,3,4]. It is the second highest cause of cancer patient fatalities in the United States, and constitutes 7.2% of the total number of cancer cases in Egypt, as estimated by Global Cancer Observatory (GLOBOCAN) in December 2020, which makes it the fifth most prevalent cancer [5,6,7]. In the vast majority of prostate cancer cases, symptoms do not manifest until later stages [8]. It is preferable to diagnose this sort of tumor as early as possible to reduce the mortality rate using normal therapy procedures [9]. Recent statistics from the World Health Organization (WHO) indicate an estimated prostate cancer death rate of around 1.7 million per year, with a rise of approximately 0.5 million by 2030 [6,10].
PSA, or prostate-specific antigen, is a glycoprotein made up of 237 amino acids that is released by the prostate gland [11]. It is used as an important biomarker for diagnosing prostate cancer by measuring its concentration in blood samples [11]. Serum PSA concentrations between 4.0 and 10.0 ng/mL are considered normal; a concentration of PSA more than 10.0 ng/mL is indicative of a carcinoma of the prostate in its first stages [12,13].
Owing to the widespread prevalence of malignant neoplasm of the prostate in men, several scientific and medical research investigations have focused on the development of simple, rapid, affordable, and accurate PSA-based-methods for early prostate cancer diagnosis, including electrochemical and fluorometric methods [14,15,16,17,18,19,20,21,22,23,24,25,26]. Unfortunately, the systems and procedures described above offer several benefits and drawbacks. Each method or technique has advantages such as sensitivity and accuracy, but is intensively solvent using and time-consuming, etc. The development of technologies and novel approaches for the detection of PSA is of major importance for early diagnosis. Accordingly, Karami et al. [27] and Yazdani et al. [28] summarized all methods that can be used in PSA detection by detecting nano-elements and their characteristics such as detecting element linear range and limit detection. Additionally, they study the parameters influencing the performance of the sensor to achieve high sensitivity [18,27,28]. Many review articles summarized different electrochemical aptamer-based biosensors for the detection of PSA [29]. They emphasized the specific performance parameters, advantages, and disadvantages of different methods, nanomaterials, and kits developed to attain highly selective and sensitive for the determination of PSA [29]. Moreover, Jalalvand et al. [30] reported many analytical techniques used for PSA detection and sometimes combined two methods such as electrochemical with chemometric methods to enhance the performance. They also mentioned several advantages of electrochemical biosensors such as good selectivity and sensitivity which has received wide attention from researchers [8,31,32]. However, most of these techniques did not have selectivity and sensitivity enough for PSA detection [33]. Herein, the fluorescence-based methods in comparison with traditional detection methods are more sensitive and faster [34].
On the other hand, the current challenges and prospects of nanomaterials-based PSA detection methods are essential. A few reports about using MOFs for PSA detection were published. Zhang et al. [35] reported an electrochemical immunosensor using MOF-235 for the sensitive detection of PSA [35]. The common nanomaterials-based biosensors used for prostate cancer (PSA) detection were reviewed and emphasized [33,36,37].
Therefore, in this paper, we aim to build a simple and rapid technique that combines the benefits of the aforementioned approaches and reduces their limits by leveraging the applicability, selectivity, and sensitivity of nanotechnologies [38,39,40,41,42,43,44,45,46,47]. Metal–organic frameworks nanoparticles (MOF-NPs) offer many desirable qualities, including stability both chemically and thermally, relatively high surface area and porosity, high magneticity, extremely efficient absorbency, and so on [48,49,50,51]. MOF-NPs, due to their superior physicochemical characteristics, are very selective and sensitive methods for forming bonds with both organic and biological molecules, and they may be dealt with more effectively than the rest of the components by relatively simple means [52]. In addition, MOF-NPs’ unique features allow them to be used in a wide range of fields, from sensing and biomedical to drug delivery and gas separation/storage, to catalysis and beyond [53,54,55,56,57,58].
Herein, Zn-MOFs-NP was synthesized via reacting zinc acetate with N1,N3-bis(2-(3-((l1-oxidaneyl)carbonyl)-5-aminobenzamido)phenyl)-5-aminoisophthalamide as a nano-organic linker which was previously reported [56]. Various micro/analytical techniques were employed to demonstrate that the synthesized Zn-MOFs-NP had the suggested structure and form. The PL study findings influenced the selection of Zn-MOFs-NP as a biosensor for detecting and measuring prostate-specific antigen (PSA). PSA concentration increases were shown to improve the PL emission spectrum of Zn-MOFs-NP. The MOF compound might thus be directed to use as a biosensor to quantify PSA levels. In addition, common tumor biomarkers and other biomolecules did not demonstrate any impact. The present method has also been compared to earlier research. The Zn-MOFs-NP-based PSA detection approach was superior to the others in terms of throughput, simplicity, cost, sensitivity, selectivity, and usability. Analytical and statistical analyses, as well as testing on the improvement mechanism and acute thermal stability, were performed on the proposed biosensor to see whether it could be utilized with actual blood samples [59,60].

2. Materials and Methods

2.1. Materials

Zinc acetate (99.99%) and 1, 2-phenylenediamine (99.5%) were acquired by Sigma- Aldrich. From Acros-organics 5-aminoisophthalic acid (98%) was purchased. Different buffered concentrations of standard-PSA were acquired from Monobind, USA. Both chemicals and solvents used as received in this study were analytical reagent grade.

2.2. Instruments

The FE-SEM/EDX spectroscopy was carried out with “FE-ESM-JEOL-JSM-6510LV- Japan”. The phases of structures were assessed by “HR-TEM-JEM-2100-JEOL, Japan”. The solid sample of a Zn-MOFs-NP was applied for mass spectroscopy using “Thermo-Scientific-mass spectrometer-USA”. FT-IR spectra in a range (400–4000 cm−1) were performed by “JASCO-FT-IR-460-spectrophotometer, USA” using KBr tablets. C-H-N-elemental analysis was accomplished via “ECS-4010-Costech analyzer-Italy”. UV-vis spectra were performed using “JASCO V-770 UV-Visible/NIR spectrophotometer-USA” and the software used for calculation of the energy band gap was Optbandgap-204B. The Zn-MOFs-NP species and oxidation states were verified by “Thermo Scientific X-ray photoelectron spectrometer, USA”. The thermogravimetric and thermal behavior analysis of the Zn-MOFs-NP (DSC/TGA) was performed by “Universal V4.5-TA analyzer-USA”. The Zn-MOFs-NP magnetic futures were investigated by “7400-1-VSM magnetometer-USA”. The photoluminescence (PL) investigation was carried out with “Shimadzu-RF-5301PC-spectrofluorophotometer-Japan). The samples measurements were accomplished in a 1.0 cm quartz cuvette path length at 30 s scan time and at 25 °C. The software used for data analysis was Origin-8, whereas the program used for drawing the geometrical 3D structures and Schemes was “ChemBioDraw-Ultra12”.

2.3. Synthesis of Zn-MOFs-NP

The MOF nanoparticle of Zn(II) was produced by adding 2.0 mmol of zinc II acetate dropwise to the synthesized N1,N3-bis(2-(3-((l1-oxidaneyl)carbonyl)-5-aminobenzamido)phenyl)-5-aminoisophthalamide (ABAPAPA) linker which was prepared according to previous report [56], followed by 24 h of stirring and reflux at 80 °C. After a time, the solution became brown, and an off-white precipitate formed, which was filtered, washed, and eventually dried at room temperature (Figure S1, Supplementary Material).

2.4. PL-Measurements Procedures

By dissolving an adequate quantity of Zn-MOFs-NP in DMSO, a concentration of (1 mM) stock solution was obtained. A working solution (10 mM) was produced by diluting the stock solution with deionized water. Then, the sample solution was evaluated for PL measurements to determine the optimal excitation wavelength by choosing the maximum wavelength emission. The PL spectrum of Zn-MOFs-NP (10 mM) was investigated against appropriate concentrations that were freshly prepared of PSA, as biomolecules and significant tumor biomarkers. The PL-intensity at ƛEm = 366 nm after an excitation wavelength of 305 nm was shown to be linearly related to PSA concentration between 0.1 and 0.2 fg/mL under the most ideal PL measuring circumstances. Parameters of the equation, including the correlation coefficient, were calculated using the least-squares method of statistics. The equation that was used was (Y = n + n’X), where Y represents the PL intensity of the Zn-MOFs-NP at em = 372 nm, n represents the intercept, n’ represents the slope, and X is the concentration of PSA. Moreover, the LOQ and LOD were determined using the following equations: ( L O Q = 10   ( S b ) & L O D = 3.3   ( S b ) ) [61,62,63]. (S) is the standard-error value of the PL intensity; (b) is the slope of the linear-graph. Zn-MOFs-NP PL spectra were also examined to those of true blood samples that had been treated with various amounts of PSA.

2.5. PSA Determination by MOF in Real-Samples

The serum samples that are considered to be representative were taken from a disposable sample that was located in a medical laboratory. The samples were evaluated and processed in accordance with the standard recommendations and safety procedures.

3. Results

The Zn-MOFs-NPs were made by reacting zinc II acetate with the N1,N3-bis(2-(3-((l1-oxidaneyl)carbonyl)-5-aminobenzamido)phenyl)-5-aminoisophthalamide compound in nano form represented as a linker in a simple way, as shown in Figure S1 (Reaction Scheme). After obtaining a precipitate with a somewhat off-white color, the substance was filtered, then washed, and, lastly, dried. Based on the collected micro/analytical data, a suggested structure was performed and evaluated.

3.1. FE-SEM, EDX and HR-TEM

The FE-SEM and EDX images of Zn-MOFs-NP are presented in (Figure 1a–c). The FE-SEM images of Zn-MOFs-NP at different magnifications (Figure 1a,b) looked to be an aggregation of inconsistent square forms (1a) and nearly inconsistent square wood shapes with proportionally sized dimensions of around 118 nm (1b). The mapping analysis of the Zn-MOFs-NPs using EDX (Figure 1c and Table 1) revealed the existence of carbon, oxygen, nitrogen, and zinc as a building block element in every single particle surface. EDX mapping (Figure 1c) confirmed the formation of the Zn-MOFs-NP structure by displaying a uniform distribution of block components throughout the cross-section. Similarly, the mapping element percentages from the EDX Table (Table 1) were in close agreement with the approximate proportion of theoretical elements. Theoretically, C is 40.18, N is 6.83, O is 28.99, and Zn is 18.23. In practice, C is 40.00, N is 6.57, O is 34.87, and Zn is 18.56. The Zn-MOFs-NP TEM picture (Figure 1d) shows irregular square nanosheets with a moderate size of around 120 nm. The SAED and high magnification pictures of the 3D nanostructure of square sheets are shown in (Figure 1e,f). High-resolution TEM (1e) and its selected area electron diffraction (SAED) pattern (1f) suggest the high crystallinity of Zn-MOF, which was confirmed by XRD.

3.2. Elemental Analysis

Table 1 displays the EDX mapped and theoretically predicted CHN-elemental data for the Zn-MOFs-NP compound. The findings were in good agreement with the predicted molecular formulas; the Anal./Calc. (percent): C48H82N7O26Zn4, (1434.730 gmol−1), N, 6.83; H, 5.76; C, 40.18; found N, 6.82; H, 5.95; C, 39.96; with a reaction yield of around 87.80 percent.

3.3. Mass Spectrum

The mass spectrum of the Zn-MOFs-NP compound (Figure S2) and the proposed fragmentation strategy (Figure S3) were illustrated. The figures depicted the m/z peaks that were perfectly consistent with the suggested empirical formula (C48H82N7O26Zn4), as computed theoretically and validated by C\H\N-analysis, a molecular ion-peak was observed at 1434.730 m/z for the Zn-MOFs-NP compound. Following fragmentation of the ion with m/z = 1434.730, Figure S3 also displays several significant peaks at m/z = 943.0, 716.0, 488.0, 229.0, 171.0, 149.0, 108.0, and 65.0 caused by the loss of (ethanol and water) molecules and the subsequent breakdown of the organic structure. The Zn-MOFs-NP compound fractured in most cases in accordance with the mass spectrum, computed theoretical fragmentations, and presumed structures of molecules.

3.4. UV-Vis and FT-IR Spectra

In contrast to the nano organic linker, the spectra chart of the IR spectroscopy of Zn-MOFs-NP is displayed in Figure S4. The typical intense peaks at 3440.0, 3140.0, 3018.0, 2928.0, and 1157.0 cm−1 are caused by the stretching band of the compound’s NH2 groups, H2O, and Et-OH molecules [64]. Continuing the interpretation, the peak at 3263.0 cm−1 is attributed to N-H stretching. It was found that the presence of sharp bands at 1640.0, 1585.0, 1560.0, 1476.0, and 1364.0 cm−1 also are attributed to C=O, C=N, and C=C stretching [41,65]. CH is assigned to the bands between 1024.0 and 771.0 cm−1. For the transition metal ions, bands at 540.0 and 418.0 cm−1 correspond to a zinc ion that interacted with O and N either with the formation of coordination and covalent bonds v ( Zn O )   and   ( Zn N ), respectively [65,66,67]. The emergence of the new intense peaks above verified the formation of coordination and covalent sharp bond of the zinc ion and the nano N1,N3-bis(2-(3-((l1-oxidaneyl)carbonyl)-5-aminobenzamido)phenyl)-5-aminoisophthalamide compound linker through the N and O. The reflection spectra (Figure S5) and bandgap energies (BGE) (Figure S6) were studied for Zn-MOF with nano-organic linkers. The Zn-MOF compound exhibited diverse reflection bands at 235.0, 271.0, 330.0, 385.0, 408.0, and 634.0 nm, as shown in Figure S5. These bands might be caused by LMCT and intra-ligand -*, n-* [68]. The BGE spectra in Figure S6 further show that the Zn-MOFs-NP has lower BGE values than the linker at 1.79, 2.95, and 3.50 eV due to conjugation inside the N1,N3-bis(2-(3-((l1-oxidaneyl)carbonyl)-5-aminobenzamido)phenyl)-5-aminoisophthalamide skeleton, which results in a higher BEG for the HOMO valance [41,55].

3.5. XRD and XPS Analysis

The XRD chart of different Zn-MOFs-NP compounds was presented in (Figure 2a). The XRD patterns of the Zn-MOFs-NP showed sharp strong peaks, indicating that the high crystalline-phase of the Zn-MOFs-NP had developed. Moreover, the diffraction patterns corresponded to normal Zn-MOF and other produced Zn-MOFs-NP XRD patterns, demonstrating the effectiveness of the Zn-MOFs-NP Synthesis method [69,70]. The nano crystallite size was estimated by the Scherrer equation provided in Tables S1 and S2, which showed the crystallite size was in the range of 120 nm. This finding has corroborated the SEM and TEM findings.
The XPS spectra (Figure 2b–e) revealed the existence of C, O, N, and Zn, only with no traces of contamination. The existence of Zn2+ in the Zn-MOFs-NP was confirmed by the detection of a signal at 1020.92 eV in the XPS spectra of Zn 2p, which was related to the Zn(II) 2p3/2 satellite peak (Figure 2b) [71]. The O 1s spectra revealed three peaks of O-Zn-O at 530.34 eV, C-O at 531.25 eV and C=O at 533.22 eV. While the satellite peak in the N 1s spectra was 398.16 eV, concurrently, the C 1s spectrum revealed the presence of three signals at 282.85 eV (C-C), 286.52 eV (C-N) and 289.59 eV C=O (Figure 2b–e) [71].

3.6. Thermal Behavior and Stability of the Zn-MOFs-NP

TGA/DSC plots of Zn-MOFs-NP indicated that the Zn-MOFs-NP compound broke down in four phases (Figure 2f). At temperatures ranging from 65 to 226.0 °C, the initial and subsequent weight losses are attributable to the liberation of C2H5OH and intra/inter H2O molecules. The organic skeleton began to degrade around 440.0 °C. This resulted in the third and fourth breakdown phases. The remainder is zinc (18.11 percent). The discussed data agreed with the results of mass spectrometry and XRD. The thermogravimetric behavior of the Zn-MOFs-NP further suggests that at temperatures up to 400.0 °C the Zn-MOFs-NP is thermally stable [72,73].
The whole presented data and discussion may be used to determine the structure of prepared Zn-MOFs-NP that exists in three dimensions and its exceptional molecular surface (Figure 3a,b). Accordingly, the 3D structure of Zn-MOF plates and morphology have intrinsic properties such as photonic bandgap, microporosity, high-spatial density, low surface energy, the defects and edge positions, complexity over length, and scales ranging and integrated with functional low-dimensional building blocks which can enhance the performance of sensing properties. Geometry with special crystal facets can provide a high large surface area and active sites, which is critically significant for highly efficient sensors.

3.7. Photoluminescence Investigation

Specifically, the PL curve was made via graphing the data of the excitation spectrum versus the emission spectra of Zn-MOFs-NP (Figure 4a). Zn-MOFs-NP photoluminescence (PL) spectra were measured and plotted (at different excitation wavelengths) in Figure S7. At an excitation wavelength of 305 nm (10 mM), the PL spectrum of Zn-MOFs-NP revealed a rise of emission band located at 366 nm. Furthermore, Zn-MOFs-NPs may be employed as optical biosensors for PSA detection and measurement.
ZMOF-NPs photoluminescence spectrum was analyzed in relation to a range of prostate-specific antigen concentrations (Figure 4b). It was found that the increase in the PSA concentrations significantly enhanced the Zn-MOFs-NP PL peak intensity in a PSA range of concentrations (0.1–0.2 fg/mL) with a small red-shift (about six nm) from 366.0 to 372.0 nm. After taking into consideration technique evaluations and statistical characteristics, the results demonstrated that ZMOF-NPs has the potential to be deemed a suitable biosensor based on spectrofluorimetric phenomena for the detection and quantification of PSA.

3.8. Method Validation

The calibration curve demonstrates the relationship between the PL intensity of ZMOFNP measured at ƛEm = 372.0 nm and the concentration of PSA in the sample, which may give rise in between 0.1 and 0.2 fg/mL (Figure S8). The linear-dynamic relationship for the Zn-MOFs-NP PL biosensor was observed (Figure 4c) under optimal circumstances for PL measurements. Rising PSA concentration significantly increased the spectrum PL intensities (Figure 4c). Over the range of interest (0.1–1000.0 fg/mL), the calibration curve was graphed linearly.
Zn-MOFs-NP PL-intensity = 105.21 log [PSA] + 523.01 with r2 = 0.983.
The limit of detection and quantification (LOD and LOQ) of the optical photoluminescence biosensor based on ZN-MOFS-NP was calculated to be 0.145 and 0.438 fg/mL, respectively, where Table S3 summarizes the results of the analysis of data using PL regression. The suggested optical photoluminescence biosensor’s low LOD and LOQ values and large linear ranges of concentrations are validated by table data. Furthermore, (Table 2) compares the new biosensor’s performance to other prior studies for PSA measurement and determination, where the present optical photoluminescence biosensor has a lower LOQ and LOD, and a broader linear detection PSA range compared to previous methods of detection.
Studies were conducted to determine the selectivity and specificity of the current optical photoluminescence Zn-MOFs-NP-based biosensor in the presence of competing analytes, such as biomolecules and other tumor biomarkers. Through the use of the PL spectrum of Zn-MOFs-NP (10.0mM) against PSA (100.0 fg/mL), CEA “carcinoembryonic antigen” (10.0 ng/mL), AFP “alpha-fetoprotein” (10.0 ng/mL), and CK-T “creatine kinase total” (10.0 ng/mL), selectivity and specificity studies were collated and exhibited in a histogram (Figure 4d). From the histogram, it can be noted that the luminescence intensity in cases of PSA is highly enhanced, whereas the other interfering analytes (similar biomarkers or organic molecules) do not make significant changes in the luminescence intensity of the Zn-MOFs-NP-based biosensor, which demonstrates the high selectivity and specificity of the proposed biosensor.
The curve demonstrates that PSA induced a considerable rise in the intensity of the Zn-MOFs-NP PL with a minor redshift, but the other interfering matrix had no reaction. As a result, we may infer that Zn-MOFs-NPs are very specific and selective for PSA when compared to other interfering matrices. Zn-MOFs-NP-based optical photoluminescence biosensors for PSA detection and measurements in genuine human blood serum samples were evaluated for their precision, accuracy, recovery, and usability. In this study, the PSA standard was spiked into blood samples at doses of 1.0, 100.0, 500.0, 1000.0, and 2000.0 fg/mL.
Three separate repetitions of each test were performed (Table 3). The mathematical calculations and statistical evaluations showed that the mean values (X) were suitable and in the range. The suggested method is precise and accurate since the observed sharp decrease in the values of relative error (RE%) averaged (1.01%) and the relative standard deviation (SD) averaged 4.270%. Importantly, the average percent recovery (RC%) was 99.02%, proving the existing optical photoluminescence biosensor is sensitive enough to detect prostate-specific antigen as an important cancer biomarker diagnostic for the prostate with pinpoint precision at very low concentrations.

3.9. Interaction Mechanism

The fluorescence mechanism of the enhancement process may be extrapolated from (Figure 4b), which indicates that when PSA concentrations increased, so did the PL-emission intensities of Zn-MOFs-NP. The shift in Zn-MOFs-NP emission intensities recorded by increasing PSA concentrations indicates the nature of the MOF-PSA interaction. The observed biochemical sensing behavior of Zn-MOFs-NP towards PSA might be ascribed to PSA’s remarkable affinity for the amine group lone pair of electrons inside Zn-MOFs-NP [64]. Furthermore, because the Zn-MOFs-NPs have low-lying “*orbitals” in amine groups of phenyl rings, the fluorescent performance of the Zn-MOFs-NP and further explanation that the interaction mechanism might be because of molecular-orbital transitions inside ligand-metal charge transfer (LMCT) resulted from intra-ligand n/-* transitions. Furthermore, the increased probability of Zn-MOFs-NP chelating with PSA as a biological target may be explained by the potential of “electron” delocalization inside the chelation ring and partial sharing of opposing positive charges with the donor-groups. According to chelation theory, this delocalization and charge-sharing process increases the lipophilic properties of the Zn-MOFs-NP and, as a result, decreases the polarity of the zinc-ion [52], implying that the interaction of Zn-MOFs-NP with PSA may be due to the formation of covalent bonds [65].

4. Conclusions

This scientific study describes an optical biosensor that employs photoluminescence and is based on a novel, promising Zn-MOFs-NP that has been thoroughly evaluated. The Zn-MOFs-NP morphology looked to be inconsistent square wood forms with an appropriate size of around 118 nm. The thermal stability measurements further demonstrated that the Zn-MOFs-NPs were considered stable. The photoluminescence investigation findings suggested that Zn-MOFs-NP might be employed as an advantageous optical biosensor for determining PSA content in actual human blood serum. From a statistical perspective, the current method served its intended function well. The provided results of the suggested approach showed lower PSA LOD with a response that was faster, easier, and cheaper than those reported in the literature. Moreover, the data unveiled in the not-so-distant future will be an essential piece for monitoring and quantifying PSA, a useful diagnostic tool for identifying prostate cancer early on—which is the most frequent malignancy in males worldwide—and therefore aids in monitoring public concerns about the health of men.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/bios12110931/s1, Figure S1: The proposed mechanism of the Zn-MOFs-NP synthesis; Figure S2: Mass spectrum of the Zn-MOFs-NP; Figure S3: The proposed fragmentation Scheme of the Zn-MOFs-NP; Figure S4: FT-IR spectra of Zn-MOFs-NP and nano organic linker; Figure S5: The electronic-reflection spectra of Zn-MOFs-NP and nano organic linker; Figure S6: The bandgap energy spectra of Zn-MOFs-NP and nano organic linker; Figure S7: The PL emission spectra at different excitation wavelength for the Zn-MOFs-NP; Figure S8: A full relationship (calibration graph) between the PL intensity of Zn-MOFs-NP and the logarithm PSA concentration (log [PSA]); Table S1: Summary of XRD data, Miller indices and interplanar distances of Zn-MOFs-NP; Table S2: Summary of calculated crystallite size of Zn-MOFs-NP at different position on XRD patterns; Table S3: Sensitivity and regression parameters for Zn-MOFs-NP chemosensor.

Author Contributions

Conceptualization, S.M.E.-S. and S.M.S.; methodology, S.M.S. and S.R.S.; validation, S.M.E.-S. and S.M.S.; formal analysis, S.M.E.-S., S.M.S. and S.R.S.; investigation, S.M.E.-S. and S.M.S.; resources, S.M.E.-S., S.M.S. and M.M.A.-E.; data curation, S.M.E.-S. and S.M.S.; writing—original draft preparation, S.M.E.-S. and S.M.S.; writing—review and editing, S.M.E.-S., S.M.S., S.R.S., A.A.L., M.M.A.-E. and A.S.B.; visualization, S.M.E.-S. and S.M.S.; supervision, S.M.E.-S., S.M.S. and M.M.A.-E.; project administration, S.M.E.-S., S.M.S. and M.M.A.-E.; funding acquisition, S.M.E.-S. and M.M.A.-E. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the financial support of the Science and Technology Development Fund (STDF) Foundation of the project no. (37068). And The APC was (100.00%) discount voucher.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki, and approved by the Medical Research Ethics Committee (MREC)—Federal Wide Assurance No. 00014747—at the National Research Centre, Egypt, decision No. 20169, on November 05-2020.

Informed Consent Statement

In this study, we did not use the samples in any research involving human participants or research involving physical interventions on study participants or involving processing of personal data but conducted the research according to the method described in the article.

Data Availability Statement

All data generated or analyzed during this study are included in this published article (and its supplementary information files).

Acknowledgments

The acknowledge the financial support of the Science and Technology Development Fund (STDF) Foundation.

Conflicts of Interest

The authors declare that they have no conflict of interest.

References

  1. Karunasinghe, N.; Minas, T.Z.; Bao, B.Y.; Lee, A.; Wang, A.; Zhu, S.; Masters, J.; Goudie, M.; Huang, S.P.; Jenkins, F.J.; et al. Assessment of Factors Associated with PSA Level in Prostate Cancer Cases and Controls from Three Geographical Regions. Sci. Rep. 2022, 12, 55. [Google Scholar] [CrossRef]
  2. Hoffman, S.S.; Smith, A.W.; Kent, E.E.; Doria-Rose, V.P.; Kobrin, S.C.; Mollica, M.A. Examination of Prostate-Specific Antigen (PSA) Screening in Military and Civilian Men: Analysis of the 2018 Behavioral Risk Factor Surveillance System. Cancer Causes Control 2022, 33, 393–402. [Google Scholar] [CrossRef] [PubMed]
  3. Ji, S.; Lee, M.; Kim, D. Detection of Early Stage Prostate Cancer by Using a Simple Carbon Nanotube@paper Biosensor. Biosens. Bioelectron. 2018, 102, 345–350. [Google Scholar] [CrossRef]
  4. Yang, C.; Guo, Q.; Lu, Y.; Zhang, B.; Nie, G. Ultrasensitive “Signal-on” Electrochemiluminescence Immunosensor for Prostate-Specific Antigen Detection Based on Novel Nanoprobe and Poly(Indole-6-Carboxylic Acid)/Flower-like Au Nanocomposite. Sens. Actuators B Chem. 2020, 303, 127246. [Google Scholar] [CrossRef]
  5. Global Cancer Observatory. Available online: https://gco.iarc.fr/ (accessed on 17 October 2022).
  6. Du, D.; Fu, H.J.; Ren, W.; Li, X.L.; Guo, L.H. PSA Targeted Dual-Modality Manganese Oxide–Mesoporous Silica Nanoparticles for Prostate Cancer Imaging. Biomed. Pharmacother. 2020, 121, 109614. [Google Scholar] [CrossRef] [PubMed]
  7. Wei, C.; Tian, L.; Jia, B.; Wang, M.; Xiong, M.; Hu, B.; Deng, C.; Hou, Y.; Hou, T.; Yang, X.; et al. Association between Serum Triglycerides and Prostate Specific Antigen (PSA) among U.S. Males: National Health and Nutrition Examination Survey (NHANES), 2003–2010. Nutrients 2022, 14, 1325. [Google Scholar] [CrossRef]
  8. Thunkhamrak, C.; Chuntib, P.; Ounnunkad, K.; Banet, P. Highly Sensitive Voltammetric Immunosensor for the Detection of Prostate Specific Antigen Based on Silver Nanoprobe Assisted Graphene Oxide Modified Screen Printed Carbon Electrode. Talanta 2020, 208, 120389. [Google Scholar] [CrossRef]
  9. Etzioni, R.; Urban, N.; Ramsey, S.; McIntosh, M.; Schwartz, S.; Reid, B.; Radich, J.; Anderson, G.; Hartwell, L. The Case for Early Detection. Nat. Rev. Cancer 2003, 3, 243–252. [Google Scholar] [CrossRef]
  10. Akl, M.A.; El-gharkawy, E.R.; El-mahdy, N.A.; El-sheikh, S.M.; Sheta, S.M. A Novel Nano Copper Complex: Potentiometry, DFT and Application as a Cancer Prostatic Biomarker for the Ultrasensitive Detection of Human PSA. Dalt. Trans. 2020, 49, 15769–15778. [Google Scholar] [CrossRef]
  11. Dhanasekaran, S.M.; Barrette, T.R.; Ghosh, D.; Shah, R.; Varambally, S.; Kurachi, K.; Pienta, K.J.; Rubin, M.A.; Chinnaiyan, A.M. Delineation of Prognostic Biomarkers in Prostate Cancer. Nature 2001, 412, 822–826. [Google Scholar] [CrossRef] [PubMed]
  12. Byun, H.J.; Shin, T.J.; Jung, W.; Ha, J.Y.; Kim, B.H.; Kim, Y.H. The Value of Magnetic Resonance Imaging and Ultrasonography (MRI/US)-Fusion Biopsy in Clinically Significant Prostate Cancer Detection in Patients with Biopsy-Naïve Men According to PSA Levels: A Propensity Score Matching Analysis. Prostate Int. 2022, 10, 45–49. [Google Scholar] [CrossRef] [PubMed]
  13. Escamilla-Gómez, V.; Hernández-Santos, D.; González-García, M.B.; Pingarrón-Carrazón, J.M.; Costa-García, A. Simultaneous Detection of Free and Total Prostate Specific Antigen on a Screen-Printed Electrochemical Dual Sensor. Biosens. Bioelectron. 2009, 24, 2678–2683. [Google Scholar] [CrossRef]
  14. Vural, T.; Yaman, Y.T.; Ozturk, S.; Abaci, S.; Denkbas, E.B. Electrochemical Immunoassay for Detection of Prostate Specific Antigen Based on Peptide Nanotube-Gold Nanoparticle-Polyaniline Immobilized Pencil Graphite Electrode. J. Colloid Interface Sci. 2018, 510, 318–326. [Google Scholar] [CrossRef] [PubMed]
  15. Karami, P.; Bagheri, H.; Johari-ahar, M.; Khoshsafar, H. Dual-Modality Impedimetric Immunosensor for Early Detection of Prostate- Specific Antigen and Myoglobin Markers Based on Antibody-Molecularly Imprinted Polymer. Talanta 2019, 202, 111–122. [Google Scholar] [CrossRef]
  16. Chong, J.; Chong, H.; Hoon, J. A Chemiluminescent Dual-Aptasensor Capable of Simultaneously Quantifying Prostate Specific Antigen and Vascular Endothelial Growth Factor. Anal. Biochem. 2019, 564, 102–107. [Google Scholar] [CrossRef]
  17. Zhang, S.; Du, B.; Li, H.; Xin, X.; Ma, H.; Wu, D.; Yan, L.; Wei, Q. Metal Ions-Based Immunosensor for Simultaneous Determination of Estradiol and Diethylstilbestrol. Biosens. Bioelectron. 2014, 52, 225–231. [Google Scholar] [CrossRef]
  18. Shayesteh, O.H.; Ghavami, R. A Novel Label-Free Colorimetric Aptasensor for Sensitive Determination of PSA Biomarker Using Gold Nanoparticles and a Cationic Polymer in Human Serum. Spectrochim. Acta—Part A Mol. Biomol. Spectrosc. 2020, 226, 117644. [Google Scholar] [CrossRef] [PubMed]
  19. Chen, M.; Tang, Z.; Ma, C.; Yan, Y. A Fluorometric Aptamer Based Assay for Prostate Specific Antigen Based on Enzyme-Assisted Target Recycling. Sens. Actuators B Chem. 2020, 302, 127178. [Google Scholar] [CrossRef]
  20. Kaya, T.; Kaneko, T.; Kojima, S.; Nakamura, Y.; Ide, Y.; Ishida, K.; Suda, Y.; Yamashita, K. High-Sensitivity Immunoassay with Surface Plasmon Field-Enhanced Fluorescence Spectroscopy Using a Plastic Sensor Chip: Application to Quantitative Analysis of Total Prostate-Specific Antigen and GalNAcβ1-4GlcNAc-Linked Prostate-Specific Antigen for Prost. Anal. Chem. 2015, 87, 1797–1803. [Google Scholar] [CrossRef] [PubMed]
  21. Soukka, T.; Paukkunen, J.; Härmä, H.; Lönnberg, S.; Lindroos, H.; Lövgren, T. Supersensitive Time-Resolved Immunofluorometric Assay of Free Prostate-Specific Antigen with Nanoparticle Label Technology. Clin. Chem. 2001, 47, 1269–1278. [Google Scholar] [CrossRef] [PubMed]
  22. Zhang, G.; Yu, Y.; Zhang, L.; Lin, B.; Wang, Y.; Guo, M.; Cao, Y. Precise Detection of Prostate Speci Fi c Antigen in Serum: A Surface Molecular Imprinted Sensor Based on Novel Cooperated Signal Ampli Fi Cation Strategy. Sens. Actuators B Chem. 2020, 302, 126998. [Google Scholar] [CrossRef]
  23. Zhang, B.; Wang, H.; Xi, J.; Zhao, F.; Zeng, B. Sensors and Actuators B: Chemical A Novel Z-Scheme ZnIn2S4/WO3 Photocatalyst Based Photoelectrochemical Immunosensor for the Sensitive Detection of Prostate Speci Fi c Antigen. Sens. Actuators B Chem. 2019, 298, 126835. [Google Scholar] [CrossRef]
  24. Deng, K.; Wang, H.; Xiao, J.; Li, C.; Zhang, S. Polydopamine Nanospheres Loaded with L-Cysteine-Coated Cadmium Sul Fi de Quantum Dots as Photoelectrochemical Signal Ampli Fi Er for PSA Detection. Anal. Chim. Acta 2019, 1090, 143–150. [Google Scholar] [CrossRef] [PubMed]
  25. Ehzari, H.; Amiri, M.; Safari, M. Enzyme-Free Sandwich-Type Electrochemical Immunosensor for Highly Sensitive Prostate Specific Antigen Based on Conjugation of Quantum Dots and Antibody on Surface of Modified Glassy Carbon Electrode with Core—Shell Magnetic Metal-Organic Frameworks. Talanta 2020, 210, 120641. [Google Scholar] [CrossRef] [PubMed]
  26. Khan, M.S.; Ameer, H.; Ali, A.; Zhu, W.; Li, X.; Yang, L.; Wang, H. Label-Free Electrochemiluminescent Immunosensor for Prostate Specific Antigen Ultrasensitive Detection Based on Novel Luminophore Ag3PO4 Decorated GO. J. Electroanal. Chem. 2019, 847, 113266. [Google Scholar] [CrossRef]
  27. Karami, P.; Khoshsafar, H.; Johari-Ahar, M.; Arduini, F.; Afkhami, A.; Bagheri, H. Colorimetric Immunosensor for Determination of Prostate Specific Antigen Using Surface Plasmon Resonance Band of Colloidal Triangular Shape Gold Nanoparticles. Spectrochim. Acta—Part A Mol. Biomol. Spectrosc. 2019, 222, 117218. [Google Scholar] [CrossRef]
  28. Yazdani, Z.; Yadegari, H.; Heli, H. A Molecularly Imprinted Electrochemical Nanobiosensor for Prostate Specific Antigen Determination. Anal. Biochem. 2019, 566, 116–125. [Google Scholar] [CrossRef]
  29. Ghorbani, F.; Abbaszadeh, H.; Dolatabadi, J.E.N.; Aghebati-Maleki, L.; Yousefi, M. Application of Various Optical and Electrochemical Aptasensors for Detection of Human Prostate Specific Antigen: A Review. Biosens. Bioelectron. 2019, 142, 111484. [Google Scholar] [CrossRef]
  30. Jalalvand, A.R. Fabrication of a Novel and Ultrasensitive Label-Free Electrochemical Aptasensor for Detection of Biomarker Prostate Specific Antigen. Int. J. Biol. Macromol. 2019, 126, 1065–1073. [Google Scholar] [CrossRef]
  31. Assari, P.; Rafati, A.A.; Feizollahi, A.; Joghani, R.A. An Electrochemical Immunosensor for the Prostate Specific Antigen Based on the Use of Reduced Graphene Oxide Decorated with Gold Nanoparticles. Microchim. Acta 2019, 186, 484. [Google Scholar] [CrossRef] [PubMed]
  32. Khan, M.S.; Zhu, W.; Ali, A.; Ahmad, S.M.; Li, X.; Yang, L.; Wang, Y.; Wang, H.; Wei, Q. Electrochemiluminescent Immunosensor for Prostate Speci Fi c Antigen Based upon Luminol Functionalized Platinum Nanoparticles Loaded on Graphene. Anal. Biochem. 2019, 566, 50–57. [Google Scholar] [CrossRef] [PubMed]
  33. Farshchi, F.; Hasanzadeh, M. Nanomaterial Based Aptasensing of Prostate Specific Antigen (PSA): Recent Progress and Challenges in Efficient Diagnosis of Prostate Cancer Using Biomedicine. Biomed. Pharmacother. 2020, 132, 110878. [Google Scholar] [CrossRef]
  34. Fang, B.Y.; An, J.; Liu, B.; Zhao, Y. Di Hybridization Induced Fluorescence Enhanced DNA-Ag Nanocluster/Aptamer Probe for Detection of Prostate-Specific Antigen. Colloids Surf. B Biointerfaces 2019, 175, 358–364. [Google Scholar] [CrossRef] [PubMed]
  35. Zhang, M.; Hu, X.; Mei, L.; Zhang, L.; Wang, X.; Liao, X.; Qiao, X.; Hong, C. PSA Detection Electrochemical Immunosensor Based on MOF-235 Nanomaterial Adsorption Aggregation Signal Amplification Strategy. Microchem. J. 2021, 171, 106870. [Google Scholar] [CrossRef]
  36. Hu, Y.; Lv, S.; Wan, J.; Zheng, C.; Shao, D.; Wang, H.; Tao, Y.; Li, M.; Luo, Y. Recent Advances in Nanomaterials for Prostate Cancer Detection and Diagnosis. J. Mater. Chem. B 2022, 10, 4907–4934. [Google Scholar] [CrossRef]
  37. Perry, G.; Cortezon-Tamarit, F.; Pascu, S.I. Detection and Monitoring Prostate Specific Antigen Using Nanotechnology Approaches to Biosensing. Front. Chem. Sci. Eng. 2020, 14, 4–18. [Google Scholar] [CrossRef] [Green Version]
  38. Basaleh, A.S.; Sheta, S.M. Manganese Metal—Organic Framework: Chemical Stability, Photoluminescence Studies, and Biosensing Application. J. Inorg. Organomet. Polym. Mater. 2021, 31, 1726–1737. [Google Scholar] [CrossRef]
  39. Sheta, S.M.; El-sheikh, S.M.; Osman, D.I.; Salem, A.M.; Ali, O.I.; Harraz, F.A.; Shousha, W.G.; Shoeib, M.A.; Shawky, S.M.; Dionysiou, D.D. A Novel HCV Electrochemical Biosensor Based on a Polyaniline@Ni-MOF Nanocomposite. Dalt. Trans 2020, 49, 8918–8926. [Google Scholar] [CrossRef] [PubMed]
  40. Sheta, S.M.; El, S.M.; Mohkles, S.; Elzaher, M.A.; Wassel, A.R. A Novel Nano-Size Lanthanum Metal—Organic Framework Based on 5—Amino—Isophthalic Acid and Phenylenediamine: Photoluminescence Study and Sensing Applications. Appl. Organometal. Chem. 2019, 33, e4777. [Google Scholar] [CrossRef]
  41. Basaleh, A.S.; Sheta, S.M. Novel Advanced Nanomaterial Based on Ferrous Metal—Organic Framework and Its Application as Chemosensors for Mercury in Environmental and Biological Samples. Anal. Bioanal. Chem. 2020, 412, 3153–3165. [Google Scholar] [CrossRef]
  42. Brandt, P.; Nuhnen, A.; Öztürk, S.; Kurt, G.; Liang, J.; Janiak, C. Comparative Evaluation of Different MOF and Non-MOF Porous Materials for SO2 Adsorption and Separation Showing the Importance of Small Pore Diameters for Low-Pressure Uptake. Adv. Sustain. Syst. 2021, 5, 2000285. [Google Scholar] [CrossRef]
  43. Sheta, S.M.; El-Sheikh, S.M.; Abd-Elzaher, M.M. Promising Photoluminescence Optical Approach for Triiodothyronine Hormone Determination Based on Smart Copper Metal—Organic Framework Nanoparticles. Appl. Organometal. Chem. 2019, 33, e5069. [Google Scholar] [CrossRef]
  44. Sheta, S.M.; El-Sheikh, S.M.; Abd-Elzaher, M.M.; Salem, S.R.; Moussa, H.A.; Mohamed, R.M.; Mkhalid, I.A. A Novel Biosensor for Early Diagnosis of Liver Cancer Cases Using Smart Nano-Magnetic Metal—Organic Framework. Appl. Organometal. Chem. 2019, 33, e5249. [Google Scholar] [CrossRef]
  45. Liu, S.; Wang, L.; Tian, J.; Luo, Y.; Chang, G.; Asiri, A.M. Application of Zeolitic Imidazolate Framework-8 Nanoparticles for the Fluorescence-Enhanced Detection of Nucleic Acids. Chempluschem 2012, 77, 23–26. [Google Scholar] [CrossRef]
  46. Abdel-Rahman, L.H.; Abu-Dief, A.M.; El-Khatib, R.M.; Abdel-Fatah, S.M. Some New Nano-Sized Fe(II), Cd(II) and Zn(II) Schiff Base Complexes as Precursor for Metal Oxides: Sonochemical Synthesis, Characterization, DNA Interaction, in Vitro Antimicrobial and Anticancer Activities. Bioorg. Chem. 2016, 69, 140–152. [Google Scholar] [CrossRef] [PubMed]
  47. Sheta, S.M.; El-Sheikh, S.M.; Abd-Elzaher, M.M. Simple Synthesis of Novel Copper Metal-Organic Framework Nanoparticles: Biosensing and Biological Applications. Dalt. Trans. 2018, 47, 4847–4855. [Google Scholar] [CrossRef] [PubMed]
  48. Sheta, S.M.; Salem, S.R.; Sheikh, S.M. El A Novel Iron (III)-Based MOF: Synthesis, Characterization, Biological, and Antimicrobial Activity Study. J. Mater. Res. 2022, 37, 2356–2367. [Google Scholar] [CrossRef]
  49. Hamouda, M.A.; Sheta, S.M.; Sheha, R.R.; Kandil, A.T.; Ali, O.I.; El-Sheikh, S.M. A Novel Strontium-Based MOF: Synthesis, Characterization, and Promising Application in Removal Of152+154Eu from Active Waste. RSC Adv. 2022, 12, 13103–13110. [Google Scholar] [CrossRef]
  50. El-Sherif, D.M.; Abouzid, M.; Gaballah, M.S.; Ahmed, A.A.; Adeel, M.; Sheta, S.M. New Approach in SARS-CoV-2 Surveillance Using Biosensor Technology: A Review. Environ. Sci. Pollut. Res. 2022, 29, 1677–1695. [Google Scholar] [CrossRef]
  51. Sheta, S.M.; El-Sheikh, S.M. Nanomaterials and Metal-Organic Frameworks for Biosensing Applications of Mutations of the Emerging Viruses. Anal. Biochem. 2022, 648, 114680. [Google Scholar] [CrossRef]
  52. Sheta, S.M.; Akl, M.A.; Saad, E.; El-gharkawy, E.R.H. A Novel Cerium (III)—Isatin Schi Ff Base Complex: Application as a Kidney Biomarker for Ultrasensitive Detection of Human Creatinine. RSC Adv. 2020, 10, 5853–5863. [Google Scholar] [CrossRef]
  53. Gil-Hernández, B.; Maclaren, J.K.; Höppe, H.A.; Pasán, J.; Sanchiz, J.; Janiak, C. Homochiral Lanthanoid (iii) Mesoxalate Metal–Organic Frameworks: Synthesis, Crystal Growth, Chirality, Magnetic and Luminescent Properties. CrystEngComm 2012, 14, 2635–2644. [Google Scholar] [CrossRef]
  54. Tahli, A.; Elshaarawy, R.F.M.; Köc, Ü.; Kautz, A.C.; Janiak, C. A HKUST-1 MOF Inclusion Compound with in-Situ Reduced Copper(I) as [Cu(NCCH3)4]+ Cation Complex in the Octahedral A-Type Pore. Polyhedron 2016, 117, 579–584. [Google Scholar] [CrossRef]
  55. Alhaddad, M.; Sheta, S.M. Dual Naked-Eye and Optical Chemosensor for Morphine Detection in Biological Real Samples Based on Cr(III) Metal−Organic Framework Nanoparticles. ACS Omega 2020, 5, 28296–28304. [Google Scholar] [CrossRef]
  56. Sheta, S.M.; El-Sheikh, S.M.; Abd-Elzaher, M.M.; Ghanemc, M.L.; Salem, S.R. A Novel, Fast, High Sensitivity Biosensor for Supporting Therapeutic Decisions and Onset Actions for Chest Pain Cases. RSC Adv. 2019, 9, 20463–20471. [Google Scholar] [CrossRef] [Green Version]
  57. Dey, C.; Kundu, T. Crystalline Metal-Organic Frameworks ( MOFs ): Synthesis, Structure and Function. Acta Crystallogr. Sect. B 2014, 23, 3–10. [Google Scholar] [CrossRef]
  58. Pal, S.; Bhunia, A.; Jana, P.P.; Dey, S.; Möllmer, J.; Janiak, C.; Nayek, H.P. Microporous La-Metal-Organic Framework (MOF) with Large Surface Area. Chem.—A Eur. J. 2015, 21, 2789–2792. [Google Scholar] [CrossRef] [PubMed]
  59. Nong, W.; Wu, J.; Ghiladi, R.A.; Guan, Y. The Structural Appeal of Metal–Organic Frameworks in Antimicrobial Applications. Coord. Chem. Rev. 2021, 442, 214007. [Google Scholar] [CrossRef]
  60. Pettinari, C.; Pettinari, R.; Di Nicola, C.; Tombesi, A.; Scuri, S.; Marchetti, F. Antimicrobial MOFs. Coord. Chem. Rev. 2021, 446, 214121. [Google Scholar] [CrossRef]
  61. Abd-Elzaher, M.M.; Ahmed, M.A.; Farag, A.B.; Attia, M.S.; Youssef, A.O.; Sheta, S.M. A Fast and Simple Method for Determination of Testosterone Hormone in Biological Fluids Based on a New Eu(III) Complex Optical Sensor. Sens. Lett. 2017, 15, 977–981. [Google Scholar] [CrossRef]
  62. Abd-Elzaher, M.M.; Ahmed, M.A.; Farag, A.B.; Attia, M.S.; Youssef, A.O.; Sheta, S.M. New Optical Sensor for Determination of Hydrochlorothiazide in Pharmaceutical Preparation and Biological Fluids. Sens. Lett. 2017, 15, 525–530. [Google Scholar] [CrossRef]
  63. Ahamed, M.A.; Farag, A.B.; Ibrahim, M.H.; Kamel, A.M.; Abd-Elzaher, M.M.; Sheta, S.M. New PVC Membrane Sensors for Microdetermination of Triamterene in Different Samples. Sens. Lett. 2017, 15, 632–638. [Google Scholar] [CrossRef]
  64. Sheta, S.M.; El-sheikh, S.M.; Abd-elzaher, M.M. A Novel Optical Approach for Determination of Prolactin Based on Pr-MOF Nanofibers. Anal. Bioanal. Chem. 2019, 411, 1339–1349. [Google Scholar] [CrossRef] [PubMed]
  65. Rani, S.; Kapoor, S.; Sharma, B.; Kumar, S.; Malhotra, R.; Dilbaghi, N. Fabrication of Zn-MOF@RGO Based Sensitive Nanosensor for the Real Time Monitoring of Hydrazine. J. Alloys Compd. 2020, 816, 152509. [Google Scholar] [CrossRef]
  66. Lan, J.; Qu, Y.; Xu, P.; Sun, J.; Energy, G.; Qu, Y.; Xu, P.; Sun, J. Novel HBD-Containing Zn(Dobdc)(Datz) as Efficiently Heterogeneous Catalyst for CO2 Chemical Conversion under Mild Conditions. Green Energy Environ. 2021, 6, 66–74. [Google Scholar] [CrossRef]
  67. Qin, L.; Zheng, Q.; Hu, Q.; Dou, Y.; Ni, G.; Ye, T.; Zhang, M. Selectively Sensing and Dye Adsorption Properties of One Zn(II) Architecture Based on a Rigid Biphenyltetracarboxylate Ligand. J. Solid State Chem. 2020, 284, 121216. [Google Scholar] [CrossRef]
  68. Othman, A.I.; Kaiss, I.R.; Huda, A.H. Vanadyl VO (II) with o-Phenylenediamine Complexes: Preparation and Spectral Characterization. Res. J. Chem. Environ. 2019, 23, 43–49. [Google Scholar]
  69. Sacourbaravi, R.; Ansari, Z.; Mohammad, A.; Valiollah, K.; Esmaeil, N. Fabrication of Ag NPs/Zn-MOF Nanocomposites and Their Application as Antibacterial Agents. J. Inorg. Organomet. Polym. Mater. 2020, 30, 4615–4621. [Google Scholar] [CrossRef]
  70. Yadav, D.K.; Gupta, R.; Ganesan, V.; Sonkar, P.K.; Yadav, M. Gold Nanoparticles Incorporated in a Zinc-Based Metal-Organic Framework as Multifunctional Catalyst for the Oxygen Reduction and Hydrogen Evolution Reactions. ChemElectroChem 2018, 5, 2612–2619. [Google Scholar] [CrossRef]
  71. Hu, C.; Hu, X.; Li, R.; Xing, Y. MOF Derived ZnO/C Nanocomposite with Enhanced Adsorption Capacity and Photocatalytic Performance under Sunlight. J. Hazard. Mater. 2020, 385, 121599. [Google Scholar] [CrossRef]
  72. Hong, Y.; Sun, S.; Sun, Q.; Gao, E.; Ye, M. Tuning Adsorption Capacity through Ligand Pre-Modification in Functionalized Zn-MOF Analogues. Mater. Chem. Phys. 2020, 243, 122601. [Google Scholar] [CrossRef]
  73. Mohan, A.J.; Katari, N.K.; Nagaraju, P.; Manabolu, S. ZIF-8, Zn(NA) and Zn(INA) MOFs as Chemical Selective Sensors of Ammonia, Formaldehyde and Ethanol Gases. Mater. Chem. Phys. 2020, 241, 122357. [Google Scholar] [CrossRef]
Figure 1. (a,b) FE-SEM images of the Zn-MOFs-NP at distinct magnifications, (c) mapping analysis (EDX) of the Zn-MOFs-NP, and (df) HR-TEM) and SAED images of the Zn-MOFs-NP.
Figure 1. (a,b) FE-SEM images of the Zn-MOFs-NP at distinct magnifications, (c) mapping analysis (EDX) of the Zn-MOFs-NP, and (df) HR-TEM) and SAED images of the Zn-MOFs-NP.
Biosensors 12 00931 g001
Figure 2. (a) The XRD patterns of the Zn-MOFs-NP, (be) the XPS spectra of the Zn-MOFs-NP: [Zn 2p (b), O 1s (c), N 1s (d), and C 1s (e)]; and (f) TGA-DSC of the Zn-MOFs-NP.
Figure 2. (a) The XRD patterns of the Zn-MOFs-NP, (be) the XPS spectra of the Zn-MOFs-NP: [Zn 2p (b), O 1s (c), N 1s (d), and C 1s (e)]; and (f) TGA-DSC of the Zn-MOFs-NP.
Biosensors 12 00931 g002
Figure 3. (a) The 3D suggested structural for the monomeric unit of the Zn-MOFs-NP; (b) Advanced molecular surface illustration.
Figure 3. (a) The 3D suggested structural for the monomeric unit of the Zn-MOFs-NP; (b) Advanced molecular surface illustration.
Biosensors 12 00931 g003
Figure 4. (a) The emission and excitation spectra (black and blue lines, respectively) of Zn-MOFs-NP, (b) the PL behavior of the Zn-MOFs-NP regarding various PSA concentrations, (c) a calibration graph between the PL intensities of the Zn-MOFs-NP and the logarithm of the PSA concentrations, and (d) a histogram of the PL intensities of the Zn-MOFs-NP regarding the PSA in the presence of some interfering analytes.
Figure 4. (a) The emission and excitation spectra (black and blue lines, respectively) of Zn-MOFs-NP, (b) the PL behavior of the Zn-MOFs-NP regarding various PSA concentrations, (c) a calibration graph between the PL intensities of the Zn-MOFs-NP and the logarithm of the PSA concentrations, and (d) a histogram of the PL intensities of the Zn-MOFs-NP regarding the PSA in the presence of some interfering analytes.
Biosensors 12 00931 g004
Table 1. The elemental and EDX analysis data of the Zn-MOFs-NP compared with theoretically calculated.
Table 1. The elemental and EDX analysis data of the Zn-MOFs-NP compared with theoretically calculated.
ElementTheoretically Calculated Found C/H/N Elemental AnalysisEDX Analysis (Found)
Weight%Atomic%Net Int.Error%
Carbon40.18039.96040.00053.25055.4302.370
Hydrogen5.7605.950----
Nitrogen6.8306.8206.5707.3602.8203.670
Oxygen28.990-34.87034.85062.41012.060
Zinc18.230-18.5604.54030.601.310
Table 2. The Zn-MOFs-NP biosensor in comparison to some existing methods for the determination of PSA.
Table 2. The Zn-MOFs-NP biosensor in comparison to some existing methods for the determination of PSA.
MethodLinear Detection RangeLODReference
Electrochemiluminescence 0.001–100.0 ng/mL440 fg/mL[4]
Nano Cu(II) complex biosensor0.005–10,000 pg/mL297 fg/mL[10]
Impedimetric immunosensor0.01–100 and 1–20,000 ng/mL5.4 pg/mL[15]
Voltammetry immunosensing platform0.75–100.0 ng/mL270 pg/mL[8]
Chemiluminescence resonance energy transfer (CRET)1.0–100 ng/mL600 pg/mL[16]
Electro chemiluminescent immunosensor0.001–80 ng/mL300 fg/mL [26]
Colorimetric aptasensor0.1–100 ng/mL20.0 pg/mL[18]
Fluorometric aptamer-based assay0.05–150 pg/mL43 fg/mL[19]
Cooperate signal amplifications strategy0.001–10,000 ng/mL30 fg/mL[22]
Photoelectrochemical immunosensor0.02 pg/mL–200 ng/mL6.8 fg/mL[24]
Sandwich-type electrochemical immunosensor1.0 pg/mL–100 ng/mL0.45 pg/mL[25]
Optical PL biosensor-based Zn-MOFs-NP0.1 to 0.2 fg/mL 0.145 fg/mLThe present work
Table 3. PSA determination in real serum samples using Zn-MOFs-NP biosensor.
Table 3. PSA determination in real serum samples using Zn-MOFs-NP biosensor.
SampleSpiked PSA (fg/mL) Found (fg/mL)XSDRE %R%
Serum samples1.00000.95201.02800.94200.9740.04701.027097.400
100.00101.1396.9095.20097.743.05401.034096.740
500.00496.30501.40498.10498.62.58701.003099.720
1000.001007.71009.91018.010125.42400.9880101.20
2000.002002.62010.81992.02002.69.42500.9990100.10
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

El-Sheikh, S.M.; Sheta, S.M.; Salem, S.R.; Abd-Elzaher, M.M.; Basaleh, A.S.; Labib, A.A. Prostate-Specific Antigen Monitoring Using Nano Zinc(II) Metal–Organic Framework-Based Optical Biosensor. Biosensors 2022, 12, 931. https://doi.org/10.3390/bios12110931

AMA Style

El-Sheikh SM, Sheta SM, Salem SR, Abd-Elzaher MM, Basaleh AS, Labib AA. Prostate-Specific Antigen Monitoring Using Nano Zinc(II) Metal–Organic Framework-Based Optical Biosensor. Biosensors. 2022; 12(11):931. https://doi.org/10.3390/bios12110931

Chicago/Turabian Style

El-Sheikh, Said M., Sheta M. Sheta, Salem R. Salem, Mohkles M. Abd-Elzaher, Amal S. Basaleh, and Ammar A. Labib. 2022. "Prostate-Specific Antigen Monitoring Using Nano Zinc(II) Metal–Organic Framework-Based Optical Biosensor" Biosensors 12, no. 11: 931. https://doi.org/10.3390/bios12110931

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop