1. Introduction
The increasing global power demand and growing concerns about its environmental impacts have prompted the introduction of regulations aimed at curbing this trend. Notably among these regulations are IEC 61000-3-2 and the Climate Saver Computing Initiative [
1,
2]. IEC 61000-3-2 particularly sets the limits on harmonic currents, which increases reactive power and causes a subsequent unnecessary increase in power capacity in grid systems as well as transmission line losses. To ensure low harmonic currents, a power factor correction (PFC) converter is necessary for power electronic systems. The PFC converter ensures a high power factor (PF) and low total harmonic distortion (THD) in power systems [
3,
4].
Examples of the PF and THD regulations utilized in computer power supplies are shown in
Figure 1. The 80 PLUS certification serves as a benchmark for high-quality power supplies and offers four levels based on efficiency and PF. The highest level, titanium, demands an exceptionally high PF under 20–100% load conditions. Recently, this regulation has become more stringent, often requiring a very high PF even at a 20% load condition. In addition, IEC 61000-3-2 imposes limits on harmonic currents, effectively regulating the THD.
Among the various PFC converters, the boost PFC converter is widely utilized with continuous conduction mode (CCM) control owing to its high efficiency with a minimal number of components. In addition, it has a high PF and low THD compared with other PFC converters. However, although the boost converter is designed to operate with the CCM, when the output load is reduced in light-load conditions, the average inductor current is decreased and the inductor current starts to reach to 0 A. As a result, the CCM boost converter starts to operate with the DCM boost converter in light-load conditions. In particular, since the inductor current is small near the low input AC voltage, the DCM region occurs near 0 V of the input voltage. At that time, the inductor current still operates as the CCM near the peak of the input voltage. Therefore, the CCM and DCM regions both exist in the light-load condition. This is called mixed conduction mode (MCM), as shown in
Figure 2a [
5,
6,
7,
8,
9]. The problem with the MCM is that the DCM region makes current oscillations, as shown in
Figure 2b, which degrades the PFC and THD [
10,
11,
12,
13,
14,
15,
16,
17].
Studies aimed at resolving these issues are underway [
18,
19,
20,
21,
22]. In [
20,
21,
22], various control techniques based on digital signal processing were proposed to alleviate THD concerns within MCM operation. These methods are highly effective and relatively easy to implement. However, digital integrated circuits (ICs) are more expensive compared with their analog counterparts and may be limited in terms of computational speed. In the absence of digital ICs, an alternative converter structure was introduced in [
20] and [
21] to enhance THD performance under light-load conditions. In [
20], various snubbers were incorporated to suppress resonance between parasitic components. Although this approach improved the THD and PF, it introduced power losses within the snubber circuit. Consequently, Ref. [
21] proposed a converter structure that maintained efficiency without degradation. This method eliminates the MCM operation by exclusively operating in CCM and DCM. Under heavy-load conditions, it operates in pure CCM operation and transitions to complete DCM operation as the output load decreases. This innovative approach harnesses the advantages of both CCM and DCM, resulting in a high PF and efficiency. However, implementing this method requires the addition of two extra thyristors and their associated gate signals, thereby increasing the complexity and cost of the system. In [
22], the authors proposed a new controller structure to modulate the on-time of the PFC converter. By increasing the on-time of the converter near the peak current and decreasing the on-time near zero voltage, they improved the THD of the converter. However, this also required two additional switches, a resistor, a capacitor, and an amplifier to implement the proposed controller.
To resolve these challenges, this study presents a novel method to improve THD by utilizing simple passive components. The proposed method involves increasing the switching frequency near the zero-crossing point of the line voltage to minimize the DCM region. Further, it involves decreasing the switching frequency near the peak of the line voltage to reduce switching losses. This method relies on only a few components; thus, it offers a simple and versatile solution that is applicable to a wide range of analog ICs.
2. Concept of the Proposed Scheme
As shown in
Figure 2, the CCM boost PFC operates with DCM when the average current of the boost inductor decreases compared with the ripple of the boost inductor. The boundaries between the CCM and DCM regions can be determined as follows:
where
is the input current,
is the current ripple of the inductor,
Vline is the line voltage,
Dswitch is the duty ratio of the switch,
Lboost is the boost inductor, and
fswitching is the switching frequency. Therefore, the DCM region decreases by increasing the switching frequency, resulting in improved THD and PF. However, although a high frequency improves the PF and THD, the frequency cannot be easily increased by the general power supply because it causes high switching losses at the switches. Thus, the proposed method adopts frequency modulation, as shown in
Figure 3.
The proposed scheme utilizes a high switching frequency near the zero-crossing area to reduce the DCM region. Moreover, near the peak of the line voltage, a low switching frequency is employed to reduce switching losses at the switch. Consequently, compared with the conventional method that employs a constant frequency, the proposed converter has a reduced DCM region owing to the high switching frequency near the zero-crossing area. This leads to a high PF and low THD. In addition, the proposed converter utilizes a lower switching frequency compared with the conventional converter near the peak line voltage, thereby avoiding an increase in switching losses at the switch. Therefore, the proposed method enables the boost PFC converter to achieve a high PF and low THD without compromising efficiency. To validate the effectiveness of the proposed method, we varied the switching frequency from 40 to 80 kHz and compared it with the conventional boost PFC converter that operates at 60 kHz. Notably, the frequency variation can be modulated from 50 to 70 kHz or 30 to 90 kHz. However, the impact on the electromagnetic interference (EMI) filters at the input stage should be considered during frequency variations, as excessively low frequencies can affect these filters.
4. Experimental Results
The effectiveness and feasibility of the proposed frequency modulation scheme were validated by utilizing a 60 Hz/230 Vac input and 850 W/380 V output prototypes. Generally, the CCM boost PFC converter operates at a relatively low switching frequency owing to its inability to achieve zero-voltage switching during CCM operation. Therefore, the general CCM boost PFC converter operates near 60 kHz, so the center-switching frequency of the proposed converter was designed to be 60 kHz. The frequency varied from approximately 40 kHz to 80 kHz. The frequency range can be modulated by utilizing four resistor values in the analog IC or by calculating the value for the digital IC. In this experiment, we compared the proposed boost PFC converter with a conventional CCM boost PFC converter with analog control prototypes.
The experimental specifications and design examples of the prototype converters are listed in
Table 1. As previously mentioned, both topologies are based on the CCM boost PFC converter. The proposed converter incorporates a frequency modulation scheme to reduce the DCM region under light-load conditions. The target application of this converter is a server power supply because the power supply for data centers is subject to strict regulations owing to its high power consumption and reliability. Therefore, achieving high efficiency, high PF, and low THD is crucial and a challenging objective for a server power supply. The input voltage for the experiment was 220 V
ac/60 Hz, corresponding to a high line voltage. This voltage was converted to 380
VDC by utilizing a boost converter. The output power was set at 850 W. To implement the CCM boost PFC converter, we utilized the widely used Infineon ICE3PCS03G [
23], which offers various subfunctions and facilitates easy designs. However, it operates at a constant switching frequency. Although ICE3PCS03G is designed for CCM control using four resistors and the sensed input voltage
VAC_det, it can also operate with frequency modulation control. For the proposed converter, we applied external resistors
Ra, Rb, Rc, and
RT using small 1608 chip resistors with values of 36 kΩ, 51 kΩ, 510 kΩ, and 130 kΩ, respectively, as per Equation (2). By utilizing these resistors, the proposed converter could operate within a frequency range of 40 to 80 kHz. To compare the performance, the conventional CCM boost PFC converter was tested at switching frequencies of 40, 60, and 80 kHz.
The testbed for the prototype converters is shown in
Figure 9. To ensure precise measurement of the PF and THD, a Yokogawa WT3000 power analyzer [
24] was utilized. This power analyzer boasts an exceptional accuracy of 0.02%. In addition, it offers a bandwidth range from 0.1 Hz to 1 MHz for PF and THD measurements. The output power was measured by utilizing a Yokogawa WT1600 power analyzer [
25].
Figure 10 and
Figure 11 show key waveforms of both prototype converters at a 20% load condition. Although both converters are designed to operate with CCM, they operate with MCM operation in light-load conditions. Since the PFC converters are designed to operate with CCM over a 50% load condition, they start to operate with DCM under a 50% load condition. And because the advantage of the proposed frequency modulation scheme is to decrease the DCM region in MCM operation, the effectiveness of the proposed converter is analyzed by focusing on the light load such as a 20% load condition. For both figures, the yellow line is a 60 Hz input high line voltage with 220 VAC, and the blue line is a current waveform of the boost inductor. Since the switching frequency of the boost converter is relatively high compared to the 60 Hz line frequency, it is shown as a ripple current shape. Lastly, the red line is an input current waveform flowing between rectifier diodes and an input capacitor of the boost converter. Since there is an input capacitor between the boost converter and the rectifier diodes, the input current can be a clear sine wave even though the inductor current has a large ripple current. And the input current near zero-crossing has a small discrete current due to the dead zone.
As shown in
Figure 10, the conventional boost PFC converter has a DCM region owing to the low-output power condition. The width of the DCM region increases as the output power decreases. In particular, under the 20% load condition, the DCM region occupies approximately 56% of the line cycle, whereas the CCM region occupies approximately 44%. Determining the inductor current from the waveform is challenging as it is filtered by the input capacitor between the rectifier diodes and boost inductor. However, precise measurement is possible by utilizing the WT3000 power analyzer. In the DCM region, numerous suboscillations caused by resonances between parasitic components occur, resulting in a decrease in the average value of the input current. Consequently, distortions in the input current are observed and represented as a red line in the measurement. As shown in the figure, the conventional CCM boost PFC converter has a THD value of 9.51% at a load condition of 20%. This value is quite low because the THD generally increases under light-load conditions. However, owing to the stringent THD regulations for server power supplies, even under light-load conditions, this value is considered significant. This is particularly relevant as data centers often operate under light-load conditions.
Compared with the conventional system, the proposed converter in
Figure 11 shows a considerably lower DCM region under the same output load condition. Because the switching frequency is increased near zero voltage, ripple currents are reduced compared with the conventional boost converter, and the DCM region decreases from 56% to 42%, representing a 25% reduction. On the other hand, the ripple current near the peak voltage increases from 1 A to 1.5 A due to low switching frequency. Therefore, the proposed converter achieved high-quality current through the implementation of a novel frequency modulation scheme.
The measured THD values of both converters under all load conditions are shown in
Figure 12. Notably, the proposed converter showed no improvements at heavy loads, as the THD remained consistently low. However, as the output load decreased, the DCM region increased, resulting in a significant increase in the THD. In practice, because the THD is generally low under heavy-load conditions, the key to satisfying various regulations is to have a low THD under light-load conditions. The advantages of the proposed converter are significant under light-load conditions.
The measured PF values of the prototypes are shown in
Figure 13. In general, the value of the PF is high under heavy-load conditions, similar to the THD. However, as the output load decreases, the PF starts decreasing as well. The main reason for the decrease in the light-load condition is related to the phase-leading current in the input capacitor. This current, with a different phase from the input voltage, predominantly degrades the PF. Notably, the absolute value of the phase-leading current remained constant regardless of the output load condition; thus, it significantly influenced the PF under light-load conditions. Therefore, the proposed scheme does not yield a considerable improvement in the PF, as the low PF under light-load conditions is not related to the DCM region. However, the PF consists of a displacement and distortion factor. Therefore, improving the THD has a positive effect on achieving a high PF. As a result, the PF of the proposed converter was slightly improved under light-load conditions.
The measured efficiencies of both prototype converters are shown in
Figure 14. Although the proposed converter operated at a high switching frequency to reduce the DCM region, it did not degrade the efficiency under all load conditions. This is because the proposed converter reduced the switching frequency near the peak of the input line voltage. Therefore, the proposed converter improved the PF and THD without degrading efficiency.
5. Conclusions
This study proposed a simple method to improve the THD of a CCM boost PFC converter under light-load conditions by utilizing a frequency modulation scheme. Achieving a high PF and low THD is crucial in numerous applications, particularly in server power supplies. A low PF and high THD increase the reactive power, which increases conduction loss in transmission lines. Therefore, many industrial regulations strictly govern the PF and THD. The PFC stage, which typically employs a CCM boost converter, determines the PF and THD in a power system. The CCM boost PFC converter is an excellent choice for the PFC stage owing to its simplicity, fewer number of components, and high efficiency. In addition, it has a relatively high PF and low THD compared with other PFC converters with other topologies, such as buck or buck–boost converters. However, despite its excellent performance, as technology advances and regulations become more stringent, novel methodologies must be developed to satisfy these requirements. Many related studies have been conducted to improve the power quality using various concepts. The methods employed in previous studies have proven to be highly effective in enhancing power quality. However, owing to this trade-off, some decrease the efficiency of the system, whereas others require numerous components, such as MOSFETs, resulting in an increase in cost and volume. In addition, the utilization of active components degrades the reliability of power systems. Consequently, the practical application of many of these studies to industrial products has been challenging. However, the proposed method offers a distinct advantage. While it did not significantly improve the power quality, it clearly decreased the THD and enhanced the PF through the utilization of simple passive components. In addition, frequency modulation did not degrade the overall efficiency under all load conditions, although it increased the switching frequency near zero voltage. This highlights the paramount importance of the proposed method, which prioritizes practicality and reliability through a straightforward approach. Furthermore, the proposed method can be applied to almost all analog and digital ICs. The proposed control method emerges as a strong contender for numerous applications in which THD and PFC are crucial.