Next Article in Journal
Interactive Trimap Generation for Digital Matting Based on Single-Sample Learning
Next Article in Special Issue
Active Contour Model Using Fast Fourier Transformation for Salient Object Detection
Previous Article in Journal
Specific Emitter Identification Based on Synchrosqueezing Transform for Civil Radar
Previous Article in Special Issue
Design and Implementation of a Digital Dual Orthogonal Outputs Chaotic Oscillator
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Findings about LORETA Applied to High-Density EEG—A Review

DICEAM Department, Mediterranea University of Reggio Calabria, Via Graziella Feo di Vito, 89060 Reggio Calabria, Italy
*
Author to whom correspondence should be addressed.
Electronics 2020, 9(4), 660; https://doi.org/10.3390/electronics9040660
Submission received: 30 March 2020 / Accepted: 14 April 2020 / Published: 17 April 2020
(This article belongs to the Special Issue Multidimensional Digital Signal Processing)

Abstract

Electroencephalography (EEG) is a non-invasive diagnostic technique for recording brain electric activity. The EEG source localization has been an area of research widely explored during the last decades because it provides helpful information about brain physiology and abnormalities. Source localization consists in solving the so-called EEG inverse problem. Over the years, one of the most employed method for solving it has been LORETA (Low Resolution Electromagnetic Tomography). In particular, in this review, we focused on the findings about the LORETA family algorithms applied to high-density EEGs (HD-EEGs), used for improving the low spatial resolution deriving from the traditional EEG systems. The results were classified according to their clinical application and some aspects arisen from the analyzed papers were discussed. Finally, suggestions were provided for future improvement. In this way, the combination of LORETA with HD-EEGs could become an even more valuable tool for noninvasive clinical evaluation in the field of applied neuroscience.
Keywords: high-density EEG; LORETA; EEG source localization high-density EEG; LORETA; EEG source localization

Share and Cite

MDPI and ACS Style

Dattola, S.; Morabito, F.C.; Mammone, N.; La Foresta, F. Findings about LORETA Applied to High-Density EEG—A Review. Electronics 2020, 9, 660. https://doi.org/10.3390/electronics9040660

AMA Style

Dattola S, Morabito FC, Mammone N, La Foresta F. Findings about LORETA Applied to High-Density EEG—A Review. Electronics. 2020; 9(4):660. https://doi.org/10.3390/electronics9040660

Chicago/Turabian Style

Dattola, Serena, Francesco Carlo Morabito, Nadia Mammone, and Fabio La Foresta. 2020. "Findings about LORETA Applied to High-Density EEG—A Review" Electronics 9, no. 4: 660. https://doi.org/10.3390/electronics9040660

APA Style

Dattola, S., Morabito, F. C., Mammone, N., & La Foresta, F. (2020). Findings about LORETA Applied to High-Density EEG—A Review. Electronics, 9(4), 660. https://doi.org/10.3390/electronics9040660

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop