Next Article in Journal
Digital Twin Formation Method for Distributed Generation Plants of Cyber–Physical Power Supply Systems
Next Article in Special Issue
Deep Learning Model for Global Spatio-Temporal Image Prediction
Previous Article in Journal
A Derivative-Free MZPRP Projection Method for Convex Constrained Nonlinear Equations and Its Application in Compressive Sensing
Previous Article in Special Issue
Effect of Green Supply Chain Management Practices on Environmental Performance: Case of Mexican Manufacturing Companies
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Numerical Simulation Analysis of Difference from a Radial Resistivity Testing Method for Cylindrical Cores and a Conventional Testing Method

1
School of Ocean and Earth Science, Tongji University, Shanghai 200092, China
2
Exploration and Development Research Institute, PetroChina Southwest Oil & Gasfield Company, Chengdu 610041, China
3
Shale Gas Evaluation and Exploitation Key Laboratory of Sichuan Province, Chengdu 610213, China
4
State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu 610500, China
*
Author to whom correspondence should be addressed.
Mathematics 2022, 10(16), 2885; https://doi.org/10.3390/math10162885
Submission received: 4 July 2022 / Revised: 30 July 2022 / Accepted: 6 August 2022 / Published: 12 August 2022
(This article belongs to the Special Issue Mathematical Theories and Models in Environmental Science)

Abstract

:
Rock resistivity is a major geophysical technical parameter in geological and geotechnical engineering, geothermal prospecting, and oil and gas exploration. Its accurate measurement is of great significance to achieve the goal of “carbon peak and carbon neutrality”. To solve anisotropic problems, a method to test the radial resistivity in cylindrical core samples has been proposed and has been deemed the universal method, as it has the virtues of no specially processed sample being needed and nondestructive testing. However, there is still a difference in the radial resistivities obtained from this method and another testing method that is commonly used for cuboid samples. Furthermore, the differences between these methods have not yet been made clear in China or elsewhere. Therefore, we compared the results of the above-two testing methods via numerical simulations after establishing the potential field distribution, and, in combination with their methodological principles, illustrated the differences between the resistivities determined in samples with distinct shapes obtained using the two testing methods, summarized the conditions when there was zero difference and considerable difference when using the two methods, and provided a theoretical basis for the reasonable selection of an appropriate method to test the resistivity anisotropy.

1. Introduction

In 2008, the UN Intergovernmental Panel on Climate Change (IPCC) set the goal of “carbon neutrality” to prevent the global average temperature from rising by more than 1.5 °C by the end of the current century [1,2,3,4,5,6,7]. The consumption of fossil fuels is the main source of carbon dioxide. To adapt to this new situation, oil consumption will continue to grow in the short to middle terms and will then ultimately return to its nature of being a “basic raw material”. Many existing oil and gas companies, including PetroChina, are already focusing on developing technologies for new energy resources, such as wind power, solar power, electrical energy, and hydrogen energy. However, different from other energy companies, oil and gas companies have the advantage of having access to subsurface resources that are currently available. Natural gas, the only fossil energy with increased use during the carbon-neutrality stage, will be the best partner for new energy resources for a long time to come. As for geothermal energy, another kind of new energy, the exploitation technologies are highly similar to those used for oil and gas.
Figuring out the physical properties of the fluid flowing in rocks has been an ongoing task in the history of “carbon peak and carbon neutrality”. Clearly, the rock resistivity discussed in this paper is a physical property. With a powerful meaning in geophysics, it is a vital parameter in the exploration domain that can be used to evaluate oil and gas reservoirs, especially for reservoir classification, fluid distribution determination, and reserve calculation [8,9,10,11,12]. Moreover, it helps geophysicists interpret and determine seismic and volcanic activities as well as large tectonic events [13,14,15,16]. Moreover, resistivity is a critical physical parameter in geological and geotechnical engineering, geothermal prospecting, and oil and gas exploration [17,18,19,20]. Therefore, obtaining an accurate and representative resistivity parameter is vital to achieving the goal of “carbon peak and carbon neutrality” as soon as possible.
Anisotropy, one of the greatest problems experienced when acquiring accurate rock resistivity measures [21,22,23], is also a universal physical property in common materials or media. Moreover, there is often a big anisotropic difference among crystals, various materials used in daily life, and earth media. The international geophysical community is well aware of the importance of anisotropy among physical properties [24,25,26]. Geophysicists once concentrated their attention on the anisotropy of thermal conductivity in rocks [27]. Jan Safanda (1995) [28] used a numerical solution to express the effects of thermal conductivity anisotropy by building a 2D anisotropy model of rocks in the geothermal field. Both David Deming (1994) [29] and Pribnow (1995) [30] set up experimental approaches to test the thermal conductivity in both cuttings and core samples at room temperature. Resistivity anisotropy is similar to thermal conductivity anisotropy. Due to their very long geological history, the sedimentation, diagenesis, and tectonism joint affecting oil and gas reservoirs may lead to reservoirs having anisotropy and different resistivity values in various directions.
For the sake of clarifying resistivity anisotropy, some scholars (including Tao Zhu, 2009 [31]; Bin Zhang, 2015 [32], 2017 [14]; Chaoqiang Fang, 2018 [33]; Qiuming Gong, 2017 [34]; and Jinzhen An, 1996 [35]) have measured anisotropy by preparing cuboid samples using diamond wire slicing or direct cutting. It is evident that the cores obtained from drilling directly are unable meet the requirements of the above methods and that the most common cores are cylindrical in shape.

2. Problem Statement

Unlike cuboid samples, it is impossible to calculate the resistivity of cylindrical samples directly. As such, in 2020, Jiahuan He et al. established a new method to test radial resistivity [36] and applied the theory of complex variable function to build a mathematical model to determine anisotropic resistivity. This new method has solved technical problems that previous methods could not determine, such as the radial resistivity of cylindrical samples. This method has been successfully applied to characterize the resistivity anisotropy in shale, sandstone, and vuggy carbonate reservoirs, which may support effective natural gas exploration and development in Sichuan Basin, China.
Figure 1a shows a rather simple experimental device that this new method (Jiahuan He, 2020 [36]) uses to test the radial resistivity of cylindrical samples, which are very common in the oil and gas domain. This method is widely useful for anisotropy characterization. As shown in Figure 1b,c, the radial resistivity is derived from ρ = K/K’ LR by fully attaching a curved electrode to the sample sidewall at a specific angle after conformal transformation as well as after Schwartz–Christoffel transformation, where in   K ( α ) = 0 1 d t ( 1 t 2 ) ( 1 α 2 t 2 ) .
It is unnecessary to restate that this method is better for solving the radial resistivity than conventional ones. However, several scholars have also pointed that when using the radial resistivity testing method, the basis for using the complex variable function is that the cores are assumed to be isotropic. However, the final results that are derived actually illustrate that they are anisotropic. Meanwhile, all of the real cylindrical cores are three-dimensional, while the two-dimensional complex variable function is adopted in this method, which also implies an assumption that the properties of the cores vary uniformly in the axial direction. Therefore, it is necessary to compare the two results individually from the radial resistivity testing method and the conventional resistivity anisotropy testing method used for cubic samples.

3. Methodology

In order to define the effectiveness of the radial resistivity testing method, a finite element numerical simulation approach was used for various samples to analyze each testing error. Previously, cube samples were used for anisotropy testing. Thus, in this testing process, all of the experiments were simulated using the numerical simulation approach. An experimental resistivity result on one cuboid numerical sample was first obtained to act as a benchmark; then, the radial resistivity of another cylindrical numerical sample with the same property was simulated; finally, the discrepancy between the two resistivities resulting from the cuboid and cylindrical samples individually was analyzed.
According to the potential field theory, the potential field distribution in the reservoir rocks can be described by the following equations:
∇∙J = Qj,v
J = σE + Je
E = −∇U
In the 3D cuboid coordinate system, the current density is as follows:
J = iJx + jJy + kJz
The divergence of the current density is expressed as follows:
∇∙J = ∂Jx/x + ∂Jy/y + ∂Jz/z
The electric field intensity is defined as follows:
E = iEx + jEy + kEz
Equation (7) describes the 3D vector value of the differential operator:
∇ = i/x + j/y + k/z
Using COMSOL Multiphysics Simulation software, the potential field distribution was obtained using finite element numerical simulation. The testing was carried out from the left ends to the right ends of the samples. For the cylindrical samples, the radial resistivity from the left end to the right end was tested using a curved electrode with a centering angle of π/2. Figure 2 shows the current direction. The yellow arrow in the figure represents the current flowing from the positive electrode to the negative electrode.
Based on the radial resistivity testing method proposed by Jianhuan He (2020 [36]), the measured resistivity value was calculated using the electrical charges across the electrode per unit time under the known potential difference.
Equation (8) expresses the potential difference between both sample ends.
U ab = Σ E d v / S
Equation (9) formulates the current passing through the electrode.
I y = S J y d s / l
Relatively, the conductivity is as follows:
ρ = R S l = U ab S J y d s / l S l = U ab S S J y d s
Equation (11) explains the resistivity of the cube sample.
ρ cube = U ab l I
Equation (12) illustrates the radial resistivity of the cylindrical sample.
ρ cylinder = U ab S S J y d s
Most of the objects in the real world have very complex anisotropy. To simplify computation, three extremes covering both lamination development and the testing direction in the samples were considered first, as shown in Figure 3.
Moderate voltage was at first imposed on both ends of the samples in the three extremes. Additionally, corresponding potential fields were then generated after the numerical simulation. Next, the resistivity of the cuboid sample and the radial resistivity of the cylindrical sample were calculated. Finally, after contrasting these two resistivities, a systematic error that appeared during radial resistivity testing was analyzed.

4. Numerical Simulation Results

To reflect the error obtained during the radial resistivity testing corresponding to the three extremes above more clearly, additional simulations were performed for two kinds of materials with resistivities of 1:10 and by supposing that the resistivities of material 1 and material 2 were 1 Ω m and 10 Ω m, respectively. The three extremes were simulated one by one. For convenience of contrast, the cross-section of the cylindrical sample on the zOx plane mentioned below was the same as that of the cube (a special cuboid) sample, and the end-circle diameter of the cylindrical sample was equal to the side length of the cube sample. Since the resistivity testing method used for the cube sample was one that is traditionally adopted to evaluate resistivity anisotropy, the testing results were taken as the denominator of the relative error between the two during later calculations. For the cylindrical sample, hi and D-hi represented the lengths of the two line segments that passed through the center of the cross-section of the cylindrical end, and they were perpendicular to the interface between the two materials and separated by the material interface in the ith instance. For the cube sample, hi and D-hi represented the thicknesses of the two materials separated by the interface in the ith instance.

4.1. Extreme 1

Supposing that the sample consisted of double-deck materials with different resistivities, the thicknesses were denoted as h1 and D-h1 for upper material 1 and lower material 2, respectively. The potential field distribution could be simplified to a cross-sectional 2D model to implement one numerical simulation because the sample resistivities were equivalent at the same Z-axis. Obviously, for both the cylindrical and cube samples, another numerical simulation was carried out using the same drawing at the cross-section on the zOx plane. The two simulation results were bound to be identical. Thus, for the radial resistivity in Extreme 1, the systematic error was 0.

4.2. Extreme 2

Supposing that the interface of the double-deck materials used in the sample was parallel to not only the zOy plane but also the current direction, and the thicknesses were denoted as h2 and D-h2 for material 1 and material 2, respectively, as shown in Figure 4. Because both cylindrical and cube samples had the same property at the same Z-axis, the model could be simplified to the projected drawing at the cross-section on the xOy plane for the numerical simulation.
Some of results from the numerical simulation can be found in Table 1. The maximum difference between the two testing methods appeared in the low-resistivity materials at the current edge because, in the radial resistivity testing method, the curved electrode failed to touch these materials, while the electrode in the cube testing electrode always touched them. As such, in Extreme 2, there was a relative difference between the two testing results. In other extremes, the difference was less than 11%. However, the results from the two testing methods were identical, and the error was zero when the double-deck materials maintained a 50–50 split.

4.3. Extreme 3

Supposing that the interface of the double-deck materials was parallel to not only the xOz plane but also the current direction, the thicknesses were denoted as h3 and D-h3 for material 1 and material 2, respectively, as shown in Figure 5. Because the cylindrical and cube samples both had the same property at the same Z-axis, the model could be simplified to the projected drawing at the cross-section on the xOy plane for the numerical simulation.
Some of the experimental results from the numerical simulation are listed in Table 2. The radial resistivity testing results differed from the other testing results obtained from the cube samples the most when the vertical direction of the current was located at one end for a few high-resistivity materials. This is because, in radial resistivity testing, both ends of the curved electrode make direct contact with the low-resistivity materials, resulting in that part of the current flowing directly from one electrode end to another end through these low-resistivity materials; however, during cube testing, the current first had to pass through the high-resistivity materials before flowing from one electrode end to another end. In the other extremes, the difference in the resistivity between the two testing methods was less than 3%. As a matter of fact, there are still several transitional cases among these three extremes, which are discussed as below.

4.4. Transitional Case 1 (from Extreme 2 to Extreme 3)

In Transitional Case 1, the case in which there was a transition from Extreme 2 to Extreme 3, there was a specific included angle between the two directions of lamination development and current, and the sample was homogeneous in the Z direction. It is easy to see from Table 3 that regardless of the included angle, the results from the two testing methods did not exceed 8% when the ratio of the low-resistivity materials to high-resistivity ones was 50/50. In the event that the two kinds of materials occupied different areas, large significant differences were only observed between the two testing methods when a small amount of high-resistivity materials was in the cylindrical end face or a when a few low-resistivity ones were on the sample margin parallel to the current direction; otherwise, the significant difference was no more than 10%.

4.5. Transitional Case 2 (from Extreme 1 to Extreme 2 and from Extreme 1 to Extreme 3)

As listed in Table 4 and Table 5, Transitional Case 2, which included one subtransition from Extreme 1 to Extreme 2 and another from Extreme 1 to Extreme 3, was studied via numerical simulation. Since these two subtransitions could not project certain overlapping current lines, interfaces, or the uniform electric field distribution on the same plane, only 3D numerical simulation was adopted for the calculation.
As listed in Table 4, for the subtransition from Extreme 1 to Extreme 2, there was a bigger difference between the two when there was a higher proportion of high-resistivity materials. As listed in Table 5, when both high-resistivity and low-resistivity materials accounted for half of the samples, there was a bigger difference between the two. However, a small difference often was often observed in other extremes and cases.

4.6. Transitional Case 3 (Transition from Extreme 1, Extreme 2, and Extreme 3)

As for Transitional Case 3, the numerical simulation could only be realized in 3D space. As listed in Table 6, when the low-resistivity materials were present in a low proportion, there was a difference of nearly 40% between the two testing results. Nevertheless, there was very little difference when there was an increase in the materials.
The numerical simulations on the above extremes and cases show that (1) there was no difference between the results of the two testing methods for Extreme 1; (2) for Extreme 2, the difference was less than 11%, with the exception of a small amount of low-resistivity materials at the current edge when there was a big difference between the two; (3) for Extreme 3, the difference was less than 3%, with the exception of when the vertical current direction of a few high-resistivity materials was at one end; and (4) for the three transitional cases, a considerable difference was observed, but the two testing results were in good agreement when the low-resistivity materials made the largest contribution.
As such, the radial resistivity testing results and the results of other tests used for the cube samples were similar as long as the lamination and current directions of the tested samples were perpendicular and parallel to each other or when small amounts of materials with very different properties did not appear at the sample edge. Extreme 1 was ideal because the two testing results were identical, and the theoretical error was zero.

5. Discussion

Both similarity and difference were observed in the testing results from the cylindrical and cube samples, which constitute two kinds of materials with different resistivities, as discussed above. Next, it is necessary to further consider exceptional circumstances and to analyze the main factors affecting the difference between these results.

5.1. Effects on Resistivity When Double-Deck Materials Feature Various Resistivity Differences

As per the above analysis, in Extreme 2, there was a great deal of difference between the two test methods when only a small number of low-resistivity materials were located at the current edge. One special circumstance with a bigger difference was chosen to set the scope of the resistivity difference from big (1:10) to small (1:1). As listed in Table 7, when the resistivity difference was less than 1:2, the two differed by just 6.66%. As listed in Table 8, when the quantity of low-resistivity materials at the current edge increased to some extent, the systematic error was only a little more than 10%, even though the resistivity difference was up to 1:10.
In Extreme 3, the radial resistivity test results differed from those of the cube testing method the most when the vertical current direction of a few high-resistivity materials was at one end. As listed in Table 9, the difference between the two dropped to 6.55% when the resistivity difference fell to 1:2, and a very considerable difference was observed at resistivity differences above 1:2. In other words, it should be noticed that in the actual measurements, the results from the two testing methods were not identical in terms of physical meaning.

5.2. Effects of Resistivity Testing Results When the Layers of Double-Deck Materials Vary from Less to More in Proportion

To estimate whether the number of material layers affected the test results, an additional numerical simulation was targeted at Extreme 2, where the number of layers increased from higher to lower. As shown from Table 10, the difference between the two testing results decreased step by step as this number increased to a certain level, and the systematic error was less than 10% for both materials as long as they constituted six or more layers.

5.3. Resistivity in the Sample Developed with One Fracture (with Saturated Water, without Saturated Water, and Different Fracture Angles)

It is assumed that individually, the resistivity was 1 Ω m for the fracture with 100% saturated brine, 2 Ω m for that with 50% saturated brine, and 4 Ω m for 25% saturated brine. Meanwhile, the matrix resistivity and the fracture width were set to 10 Ω m and 0.001 m. From the numerical simulation results listed in Table 11, it is not difficult to observe that the systematic error is no less than 6% for the sample developed with one fracture.

6. Conclusions

  • For core samples in various extremes and cases, we used numerical methods to simulate the difference between the radial resistivity test results in the cylindrical samples and the resistivity testing results in the cube samples and proved that in most extremes and cases, the agreement between the two was within the allowable error range. The cylindrical radial resistivity testing method was also confirmed to be universal and comparable to other methods that have used before. Additionally, it is an important tool for anisotropy characterization.
  • The numerical simulation results illustrate that the radial resistivity testing results in cylindrical samples were in high agreement with those obtained in cuboid samples (zero error) when the current direction was perfectly consistent with the lamination plane of the rocks.
  • The difference between the results obtained from the two testing methods was no more than 10% in most of the tested extremes and cases when the lamination plane was parallel to the current plane, with the exception of Extreme 2 and Extreme 3. When there is a small number of low-resistivity materials at the sample edge and when the interface of the different materials was parallel to the current direction (Extreme 2), the difference between the two testing results was big. The curved electrode used during radial resistivity testing failed to touch these materials, and the results were somewhat different from the test results obtained from the cube samples when the materials were in contact with the electrode end. Moreover, there was a considerable difference when the interface between two kinds of materials was parallel to the current directions (Extreme 3). A small amount of high-resistivity materials was distributed on one end, and during radial resistivity testing, it was possible for the curved electrode to make contact with the low-resistivity materials, but during cube sample testing, the electrode only touched the high-resistivity materials representing the reason for the difference.
  • Therefore, the radial resistivity testing results and the cube sample test results are comparable as long as two extra-large systematic errors and certain special circumstances can be avoided in transitional cases during testing. In these special circumstances, the reason why the systematic error is large is that these circumstances have different physical meanings that require a more appropriate testing method to be selected according to concrete testing purposes.

Author Contributions

Conceptualization: J.H., T.L., L.W. (Long Wen) and M.L.; methodology: J.H.; software, J.H. and J.L.; validation: J.H., T.H., L.W. (Long Wen) and X.Y.; formal analysis: T.H.; investigation: J.H., T.L., L.W. (Long Wen) and M.L.; resources: L.W. (Long Wen) and L.W. (Li Wang); data curation: X.Y.; writing—original draft preparation: J.H. and T.H.; writing—review and editing: T.H.; visualization: T.H.; supervision: T.H.; project administration: J.H.; funding acquisition: J.H. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by special funds for local science and technology development fund guided by the central government of Sichuan Province (No. 2020ZYD062).

Data Availability Statement

Data are available from the corresponding author upon reasonable request.

Acknowledgments

The authors would like to thank Zhou Keming, Zeng Li, Li Nong, Tang Zhijuan, Liu Tingzhi, and Zou Mengwen for their experiments, guidance, and suggestions. Without their assistance, this paper would not have been possible.

Conflicts of Interest

The authors declare that there are no conflict of interest regarding the publication of this paper.

References

  1. Zou, C.; Xiong, B.; Xue, H.; Zheng, D.; Ge, Z.; Wang, Y.; Jiang, L.; Pan, S.; Wu, S. The role of new energy in carbon neutral. Pet. Explor. Dev. 2021, 48, 480–491. [Google Scholar] [CrossRef]
  2. Zou, C.; Xue, H.; Xiong, B.; Zhang, G.; Pan, S.; Jia, C.; Wang, Y.; Ma, F.; Sun, Q.; Guan, C.; et al. Connotation, innovation and vision of “carbon neutral”. Nat. Gas Ind. 2021, 41, 46–57. [Google Scholar]
  3. Zhou, S.; Zhu, J. Exploration of ways to helping “Carbon Peak and Neutrality” Strategy. Nat. Gas Ind. 2021, 41, 1–8. [Google Scholar]
  4. Soeder, D.J. Greenhouse gas sources and mitigation strategies from a geosciences perspective. Adv. Geo-Energy Res. 2021, 5, 274–285. [Google Scholar] [CrossRef]
  5. Li, B.; Zhu, L.; Wang, W.; Xiong, B.; Jiang, L.; Hu, R.; Mei, Q. Integrated development strategy of natural gas and hydropower in Sichuan-Chongqing area. Nat. Gas Ind. 2021, 41, 136–143. [Google Scholar]
  6. Chen, J.; Li, Q.; He, J. Regional diversity of low-carbon efficiency in Sichuan province under the goal of carbon neutrality. Nat. Gas Ind. 2021, 41, 162–170. [Google Scholar]
  7. Liu, F.; Qin, L.; Deng, X.; Ge, L. Progress of VSP logging technology in Sichuan Basin. Nat. Gas Explorat. Dev. 2020, 43, 39–46. [Google Scholar]
  8. He, J.; Li, M.; Zhou, K.; Yang, Y.; Xie, B.; Li, N.; Dang, L.; Tang, Y. Effects of vugs on resistivity of vuggy carbonate reservoirs. Pet. Explor. Dev. 2020, 47, 527–535. [Google Scholar] [CrossRef]
  9. Tian, H.; Xin, Y.; Zhang, H.; Wang, X.; Sun, H. Identification of complex lithology based on conventional well logging: An example from T2I43 gas reservoirs, Longgang area, Sichuan Basin. Nat. Gas Explor. Dev. 2019, 42, 55–65. [Google Scholar]
  10. Hou, M.; Pan, S.; Liu, H. World energy trend and China’s oil and gas sustainable development strategies. Nat. Gas Indust. 2021, 41, 9–16. [Google Scholar]
  11. Wang, Y.; Xie, B.; Lai, Q.; He, X.; Yang, M.; Zhao, A.; Peng, X.; Han, B.; Bai, L. Petrophysical characteristics of deep dolomite reservoirs with and well-logging evaluation methods. Nat. Gas Explor. Dev. 2021, 44, 63–70. [Google Scholar]
  12. Luo, Q.; Li, J.; Lei, X.; Xu, Q.; Dai, B.; Ma, W.; Qin, W.; Yuan, Z. Deep earth fluids: Basic characteristics and energy effects. Nat. Gas Explor. Dev. 2021, 44, 1–8. [Google Scholar]
  13. Chen, F.; An, J.; Liao, C. Directional characteristic of resistivity changes in rock of original resistivity anisotropy. Chin. J. Geophys. 2003, 46, 271–280. [Google Scholar] [CrossRef]
  14. Zhang, B.; Zhu, T.; Zhou, J. Experimental studies on the changes of rock resistivity image and anisotropy. Acta Seismol. Sin. 2017, 39, 478–494. [Google Scholar]
  15. Pavel, B.; Edward, F. New interpretation of the reduction phenomenon in the electrical resistivity of rock masses before local earthquakes. Phys. Earth Planet. Inter. 2019, 294, 106279. [Google Scholar]
  16. Luo, N.; Zhang, J.; Li, J.; Xin, S. Development and utilization prospect of the geothermal resources in the buried hills of the Xiong’an New Area and its periphery. Nat. Gas Ind. 2021, 41, 160–171. [Google Scholar]
  17. Wang, C.; Xu, Y.; Gao, X. Rock resistivity characteristics and its application in coal mine goaf exploration. Coal Eng. 2020, 52, 64–69. [Google Scholar]
  18. Jesus, G.; Jean-Christophe, C.; Anatoly, L.; Ulrich, O.; David, H. Quantification of groundwater storage heterogeneity in weathered/fractured basement rock aquifers using electrical resistivity tomography: Sensitivity and uncertainty associated with petrophysical modelling. J. Hydrol. 2021, 593, 125637. [Google Scholar]
  19. Zhang, S.; Wang, Y.; Tong, Y.; Chen, Y.; Li, Z.; Niu, D. Flexural toughness characteristics of basalt fiber reinforced shotcrete composites in high geothermal environment. Constr. Build. Mater. 2021, 298, 123893. [Google Scholar] [CrossRef]
  20. Kayode, J.; Adelusi, A.; Nawawi, M.; Bawallah, M.; Olowlafe, T. Geo-electrical investigation of near surface conductive structures suitable for groundwater accumulation in a resistive crystalline basement environment: A Extreme study of Isuada, southwestern Nigeria. J. Afr. Earth Sci. 2016, 119, 289–302. [Google Scholar] [CrossRef]
  21. Sergey, K.; Ekaterina, P.; Irina, A.; Vitaliy, D.; Elena, D.; Denis, S.; Konstantin, B. Mathematical Model of Electrical Conductivity of Anisotropic Nanocomposite with Periodic Structure. Mathematics 2021, 9, 2948. [Google Scholar]
  22. Wang, F.; Xie, X.; Dong, L. Anomalous Areas Detection in Rocks Using Time-Difference. Adjoint Tomography. Mathematics 2022, 10, 1069. [Google Scholar] [CrossRef]
  23. Panja, P.; McLennan, J.; Green, S. Impact of permeability heterogeneity on geothermal battery energy storage. Adv. Geo-Energy Res. 2021, 5, 127–138. [Google Scholar] [CrossRef]
  24. Cao, Q.; Fang, C.; Li, Y.; Wang, H.; Fang, Q.; Shi, X. Development status of geothermal reinjection at home and abroad and its enlightenment. Oil Drill. Prod. Technol. 2021, 43, 203–211. [Google Scholar]
  25. Zhan, H.; Dong, W.; Chen, S.; Hu, D.; Zhou, H.; Luo, J. Improved test method for convection heat transfer characteristics of carbonate fractures after acidizing etching. Adv. Geo-Energy Res. 2021, 5, 376–385. [Google Scholar] [CrossRef]
  26. Emil N., M.; Sergey P., R.; Nail G., M. Hierarchical Approach to Identifying Fluid Flow Models in a Heterogeneous Porous Medium. Mathematics 2021, 9, 3289. [Google Scholar]
  27. Yu, G.; Liu, C.; Zhang, L.; Fang, L. Parameter sensitivity and economic analyses of an interchange-fracture enhanced geothermal system. Adv. Geo-Energy Res. 2021, 5, 166–180. [Google Scholar] [CrossRef]
  28. Šafanda, J. Effect of thermal conductivity anisotropy of rocks on the subsurface temperature field. Geophys. J. Int. 2010, 120, 323–330. [Google Scholar] [CrossRef]
  29. David, D. Estimation of the thermal conductivity anisotropy of rock with application to the determination of terrestrial heat flow. J. Geophys. Res. 1994, 99, 22087–22091. [Google Scholar]
  30. Daniel, F.; John, H. Determination of thermal conductivity for deep boreholes. J. Geophys. Res. Solid Earth 1995, 100, 9981–9984. [Google Scholar]
  31. Zhu, T.; Zhou, J.; Hao, J. Resistivity anisotropy and its applications to earthquake research. Prog. Geophys. 2009, 24, 871–878. [Google Scholar]
  32. Zhang, B.; Zhou, J. The experimental study on rock resistivity. CT Theory Appl. 2015, 24, 239–249. [Google Scholar]
  33. Fang, C.; Li, X.; Wang, J.; Cai, C.; Cai, C. Rock physical parameters of coal reservoir in the south of Qinshui Basin. Well Logging Technol. 2018, 42, 73–77. [Google Scholar]
  34. Gong, Q.; Zhou, X.; Yin, L.; He, G.; Miao, C. Study of rock breaking efficiency of TBM disc cutter based on chips analysis of linear cutting test. Tunn. Constr. 2017, 37, 363–368. [Google Scholar]
  35. An, J.; Xiu, J.; Chen, F.; Chen, D. Anisotropy studies of rock resistivity changes under pressure and water replenishment. Earthq. Res. China 1996, 12, 300–306. [Google Scholar]
  36. He, J.; Li, M.; Zhou, K.; Zeng, L.; Li, N.; Yang, Y.; Xiao, D.; Huang, M. Radial resistivity measurement method for cylindrical core samples. Interpretation 2020, 8, 1071–1080. [Google Scholar] [CrossRef]
Figure 1. Radial resistivity testing method: (a) experimental device; (b) top view of cylindrical core; (c) cylindrical core.
Figure 1. Radial resistivity testing method: (a) experimental device; (b) top view of cylindrical core; (c) cylindrical core.
Mathematics 10 02885 g001
Figure 2. Current direction simulated using radial resistivity testing method.
Figure 2. Current direction simulated using radial resistivity testing method.
Mathematics 10 02885 g002
Figure 3. Radial resistivity testing method corresponding to three extremes. The arrow represents the current direction during the test, and the dotted line represents the lamination direction of the rock. θ is an included angle between the lamination plane and the end, and φ is an included angle between the projection of the lamination plane on the end and the current direction: (a) Extreme 1: θ = 0, φ = 0; (b) Extreme 2: θ = π/2, φ = 0; (c) Extreme 3: θ = π/2, φ = π/2.
Figure 3. Radial resistivity testing method corresponding to three extremes. The arrow represents the current direction during the test, and the dotted line represents the lamination direction of the rock. θ is an included angle between the lamination plane and the end, and φ is an included angle between the projection of the lamination plane on the end and the current direction: (a) Extreme 1: θ = 0, φ = 0; (b) Extreme 2: θ = π/2, φ = 0; (c) Extreme 3: θ = π/2, φ = π/2.
Mathematics 10 02885 g003
Figure 4. Extreme 2: different material thicknesses.
Figure 4. Extreme 2: different material thicknesses.
Mathematics 10 02885 g004
Figure 5. Extreme 3: different material thicknesses.
Figure 5. Extreme 3: different material thicknesses.
Mathematics 10 02885 g005
Table 1. Extreme 2: numerical simulation results of different material thicknesses.
Table 1. Extreme 2: numerical simulation results of different material thicknesses.
h2D-h2 Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error 1
(%)
0.90.1 Mathematics 10 02885 i0011.036 Mathematics 10 02885 i0021.099−5.73
0.70.3 Mathematics 10 02885 i003 Mathematics 10 02885 i0041.315 Mathematics 10 02885 i0051.340−1.87
0.50.5 Mathematics 10 02885 i0061.818 Mathematics 10 02885 i0071.8180.00
0.30.7 Mathematics 10 02885 i0082.994 Mathematics 10 02885 i0092.70310.77
0.10.9 Mathematics 10 02885 i0109.008 Mathematics 10 02885 i0115.26371.16
1 Here, systematic error refers to the difference between the radial resistivity testing value and the cube sample testing value divided by the latter value.
Table 2. Extreme 3: numerical simulation results of different material thicknesses.
Table 2. Extreme 3: numerical simulation results of different material thicknesses.
h3D-h3 Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
0.90.1 Mathematics 10 02885 i012 Mathematics 10 02885 i0131.116 Mathematics 10 02885 i0141.900−41.26
0.70.3 Mathematics 10 02885 i0153.603 Mathematics 10 02885 i0163.700−2.62
0.50.5 Mathematics 10 02885 i0175.514 Mathematics 10 02885 i0185.5000.25
0.30.7 Mathematics 10 02885 i0197.276 Mathematics 10 02885 i0207.300−0.33
0.10.9 Mathematics 10 02885 i0219.319 Mathematics 10 02885 i0229.1002.41
Table 3. Transitional Case 1: numerical simulation results of different material thicknesses.
Table 3. Transitional Case 1: numerical simulation results of different material thicknesses.
h4D-h4Angle between Lamination and Y-axis Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
0.50.5 Mathematics 10 02885 i023 Mathematics 10 02885 i0241.818 Mathematics 10 02885 i0251.8180.00
0.50.545° Mathematics 10 02885 i0262.989 Mathematics 10 02885 i0273.099−3.55
0.50.590° Mathematics 10 02885 i0285.514 Mathematics 10 02885 i0295.5000.25
0.50.5135° Mathematics 10 02885 i0303.532 Mathematics 10 02885 i0313.836−7.93
0.90.1 Mathematics 10 02885 i0321.036 Mathematics 10 02885 i0331.099−5.73
0.90.145° Mathematics 10 02885 i0341.142 Mathematics 10 02885 i0351.0449.39
0.90.190° Mathematics 10 02885 i0361.117 Mathematics 10 02885 i0371.900−41.21
0.90.1135° Mathematics 10 02885 i0381.141 Mathematics 10 02885 i0391.0439.40
0.90.1180° Mathematics 10 02885 i0401.036 Mathematics 10 02885 i0411.099−5.73
0.90.1225° Mathematics 10 02885 i0421.101 Mathematics 10 02885 i0431.0623.67
0.90.1270° Mathematics 10 02885 i0441.283 Mathematics 10 02885 i0451.900−32.47
0.90.1315° Mathematics 10 02885 i0461.099 Mathematics 10 02885 i0471.0643.29
0.10.9 Mathematics 10 02885 i0489.008 Mathematics 10 02885 i0495.26371.16
0.10.945° Mathematics 10 02885 i0508.707 Mathematics 10 02885 i0519.579−9.10
0.10.990° Mathematics 10 02885 i0529.053 Mathematics 10 02885 i0539.100−0.52
0.10.9135° Mathematics 10 02885 i0548.718 Mathematics 10 02885 i0559.579−8.99
0.10.9180° Mathematics 10 02885 i0569.050 Mathematics 10 02885 i0575.26371.96
0.10.9225° Mathematics 10 02885 i0589.299 Mathematics 10 02885 i0599.563−2.76
0.10.9270° Mathematics 10 02885 i0609.969 Mathematics 10 02885 i0619.1009.55
0.10.9315° Mathematics 10 02885 i0629.323 Mathematics 10 02885 i0639.569−2.57
Table 4. Transitional Case 2 (one subtransition from Extreme 1 to Extreme 2): numerical simulation results of different material thicknesses.
Table 4. Transitional Case 2 (one subtransition from Extreme 1 to Extreme 2): numerical simulation results of different material thicknesses.
h5D-h5 Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
0.250.75 Mathematics 10 02885 i064 Mathematics 10 02885 i0655.233 Mathematics 10 02885 i0668.247−36.55
0.50.5 Mathematics 10 02885 i0672.100 Mathematics 10 02885 i0681.81815.51
0.750.25 Mathematics 10 02885 i0691.115 Mathematics 10 02885 i0701.127−1.07
Table 5. Transitional Case 2 (another subtransition from Extreme 1 to Extreme 3): numerical simulation results of different material thicknesses.
Table 5. Transitional Case 2 (another subtransition from Extreme 1 to Extreme 3): numerical simulation results of different material thicknesses.
h6D-h6 Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
0.250.75 Mathematics 10 02885 i071 Mathematics 10 02885 i0728.270 Mathematics 10 02885 i0738.0342.94
0.50.5 Mathematics 10 02885 i0742.599 Mathematics 10 02885 i0753.851−32.51
0.750.25 Mathematics 10 02885 i0761.261 Mathematics 10 02885 i0771.270−0.71
Table 6. Transitional Case 3 (transition from Extreme 1, Extreme 2, and Extreme 3): numerical simulation results of different material thicknesses.
Table 6. Transitional Case 3 (transition from Extreme 1, Extreme 2, and Extreme 3): numerical simulation results of different material thicknesses.
h7D-h7 Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
0.250.75 Mathematics 10 02885 i078 Mathematics 10 02885 i0792.506 Mathematics 10 02885 i0804.160−39.76
0.50.5 Mathematics 10 02885 i0811.254 Mathematics 10 02885 i0821.2671.02
0.750.25 Mathematics 10 02885 i0831.034 Mathematics 10 02885 i0841.0280.58
Table 7. Numerical simulation results for resistivity difference in various materials (0.1:0.9).
Table 7. Numerical simulation results for resistivity difference in various materials (0.1:0.9).
ρ1ρ2 Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
110 Mathematics 10 02885 i085 Mathematics 10 02885 i0869.008 Mathematics 10 02885 i0875.26371.16
18 Mathematics 10 02885 i0887.281 Mathematics 10 02885 i0894.70654.72
16 Mathematics 10 02885 i0905.508 Mathematics 10 02885 i0914.00037.70
14 Mathematics 10 02885 i0923.772 Mathematics 10 02885 i0933.07722.59
12 Mathematics 10 02885 i0941.939 Mathematics 10 02885 i0951.8186.66
11 Mathematics 10 02885 i0961.000 Mathematics 10 02885 i0971.0000
Table 8. Numerical simulation results for resistivity difference in various materials (0.3:0.7).
Table 8. Numerical simulation results for resistivity difference in various materials (0.3:0.7).
ρ1ρ2 Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
110 Mathematics 10 02885 i0982.994 Mathematics 10 02885 i0992.70310.77
18 Mathematics 10 02885 i1002.852 Mathematics 10 02885 i1012.58110.50
16 Mathematics 10 02885 i102 Mathematics 10 02885 i1032.625 Mathematics 10 02885 i1042.4009.38
14 Mathematics 10 02885 i1052.261 Mathematics 10 02885 i1062.1057.41
12 Mathematics 10 02885 i1071.587 Mathematics 10 02885 i1081.5383.19
11 Mathematics 10 02885 i1091.000 Mathematics 10 02885 i1101.0000
Table 9. Extreme 3: numerical simulation results for resistivity difference in various materials (0.9:0.1).
Table 9. Extreme 3: numerical simulation results for resistivity difference in various materials (0.9:0.1).
ρ1ρ2 Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
110 Mathematics 10 02885 i111 Mathematics 10 02885 i1121.116 Mathematics 10 02885 i1131.900−41.26
18 Mathematics 10 02885 i1141.105 Mathematics 10 02885 i1151.700−35.00
16 Mathematics 10 02885 i1161.090 Mathematics 10 02885 i1171.500−27.33
14 Mathematics 10 02885 i1181.067 Mathematics 10 02885 i1191.300−17.02
12 Mathematics 10 02885 i1201.028 Mathematics 10 02885 i1211.1006.55
11 Mathematics 10 02885 i1221.000 Mathematics 10 02885 i1231.0000
Table 10. Numerical simulation results of resistivity difference in various materials (0.1:0.9).
Table 10. Numerical simulation results of resistivity difference in various materials (0.1:0.9).
Number of Material Layers Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
2 Mathematics 10 02885 i124 Mathematics 10 02885 i1259.008 Mathematics 10 02885 i1265.26371.16
4 Mathematics 10 02885 i1276.437 Mathematics 10 02885 i1285.26322.30
6 Mathematics 10 02885 i1295.753 Mathematics 10 02885 i1305.2639.31
8 Mathematics 10 02885 i1315.345 Mathematics 10 02885 i1325.2631.56
10 Mathematics 10 02885 i1335.066 Mathematics 10 02885 i1345.263−3.74
Table 11. Numerical simulation results when fractures are developed.
Table 11. Numerical simulation results when fractures are developed.
Fracture ConditionIncluded Angle with Current Direction Potential Field Distribution from Radial TestingResistivity Simulated by Radial Testing
(Ω m)
Potential Field Distribution from Cube TestingResistivity Simulated by Cube Testing
(Ω m)
Systematic Error
(%)
100% saturated brine Mathematics 10 02885 i135 Mathematics 10 02885 i1369.596 Mathematics 10 02885 i1379.1754.59
45° Mathematics 10 02885 i1389.329 Mathematics 10 02885 i1399.578−2.60
90° Mathematics 10 02885 i1409.924 Mathematics 10 02885 i1419.9100.14
50% saturated brine Mathematics 10 02885 i1429.860 Mathematics 10 02885 i1439.6152.55
45° Mathematics 10 02885 i1449.319 Mathematics 10 02885 i1459.788−4.79
90° Mathematics 10 02885 i1469.933 Mathematics 10 02885 i1479.9210.12
25% saturated brine Mathematics 10 02885 i1489.948 Mathematics 10 02885 i1499.8520.97
45° Mathematics 10 02885 i1509.369 Mathematics 10 02885 i1519.912−5.48
90° Mathematics 10 02885 i1529.954 Mathematics 10 02885 i1539.9400.14
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

He, J.; Liu, T.; Wen, L.; He, T.; Li, M.; Li, J.; Wang, L.; Yao, X. Numerical Simulation Analysis of Difference from a Radial Resistivity Testing Method for Cylindrical Cores and a Conventional Testing Method. Mathematics 2022, 10, 2885. https://doi.org/10.3390/math10162885

AMA Style

He J, Liu T, Wen L, He T, Li M, Li J, Wang L, Yao X. Numerical Simulation Analysis of Difference from a Radial Resistivity Testing Method for Cylindrical Cores and a Conventional Testing Method. Mathematics. 2022; 10(16):2885. https://doi.org/10.3390/math10162885

Chicago/Turabian Style

He, Jiahuan, Tangyan Liu, Long Wen, Tingting He, Min Li, Jin Li, Li Wang, and Xin Yao. 2022. "Numerical Simulation Analysis of Difference from a Radial Resistivity Testing Method for Cylindrical Cores and a Conventional Testing Method" Mathematics 10, no. 16: 2885. https://doi.org/10.3390/math10162885

APA Style

He, J., Liu, T., Wen, L., He, T., Li, M., Li, J., Wang, L., & Yao, X. (2022). Numerical Simulation Analysis of Difference from a Radial Resistivity Testing Method for Cylindrical Cores and a Conventional Testing Method. Mathematics, 10(16), 2885. https://doi.org/10.3390/math10162885

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop