Article
Peer-Review Record

Plasma A2AR Measurement Can Help Physicians Identify Patients Suspected of Coronary Chronic Syndrome: A Pilot Study

Biomedicines 2022, 10(8), 1849; https://doi.org/10.3390/biomedicines10081849
by Franck Paganelli 1,2, Gabriel Cappiello 1, Soumeya Aliouane 1, Nathalie Kipson 2, Christine Criado 2, Khadidja Hamou 1, Jehuel Ntawanga 1, Erika Peroni 3, Maria Carreno 3, Lucas Methlin 3, Giovanna Mottola 2, Julien Fromonot 2, Pierre Deharo 2,4, Marine Gaudry 5, Marion Marlinge 2,3, Régis Guieu 2,3,* and Jean Ruf 2
Reviewer 1:
Reviewer 2: Anonymous
Reviewer 3: Anonymous
Biomedicines 2022, 10(8), 1849; https://doi.org/10.3390/biomedicines10081849
Submission received: 11 July 2022 / Revised: 27 July 2022 / Accepted: 28 July 2022 / Published: 1 August 2022
(This article belongs to the Special Issue Advances in Adenosine and Adenosine Receptors)

Round 1

Reviewer 1 Report

I have no further comments.

Author Response

Answer: Thank You

Reviewer 2 Report

The manuscript titled as "Plasma A2AR Measurement Can Help Physicians 2 Identify Patients Suspected of Coronary Chronic 3 Syndrome: A Pilot Study" used homemade inhibition ELISA to measure A2AR in plasma to evaluate patients with stable CCS.

In the previous study "Production of an agonist-like monoclonal antibody to the human A2A receptor of adenosine for clinical use." shows the innovative usage of A2AR antibody. I assumed that the aim of this study is to further prove the clinical value of A2AR inhibition ELISA. However, only around 30 samples were collected in each group in this study. 

The results can be accepted, only if the samples in each group increase into 50+.

Author Response

The manuscript titled as "Plasma A2AR Measurement Can Help Physicians 2 Identify Patients Suspected of Coronary Chronic 3 Syndrome: A Pilot Study" used homemade inhibition ELISA to measure A2AR in plasma to evaluate patients with stable CCS.

In the previous study "Production of an agonist-like monoclonal antibody to the human A2A receptor of adenosine for clinical use." shows the innovative usage of A2AR antibody. I assumed that the aim of this study is to further prove the clinical value of A2AR inhibition ELISA. However, only around 30 samples were collected in each group in this study. 

The results can be accepted, only if the samples in each group increase into 50+

 

Answer: As specified previously this is a pilot study. Furthermore the statistical analysis show significant Differences in soluble A2a concentration in plasma between groups.

Reviewer 3 Report

There is not a formal reply to my previous report (or it is not accessible to me), however authors changed the text accordingly. I have few other comments:

As already underlined in my previous report I would change non-contributive electrocardiography and troponin” simply with “negative electrocardiography and troponin”.

Abstract continues to be confused in presentation as underlined in previous report. 

In flow chart  “figure 2” which is the difference between “met non inclusion criteria”  and “met exclusion criteria”. 

Author Response

here is not a formal reply to my previous report (or it is not accessible to me), however authors changed the text accordingly. I have few other comments:

Answer: Sorry

As already underlined in my previous report I would change non-contributive electrocardiography and troponin” simply with “negative electrocardiography and troponin”.

Answer: this was done

Abstract continues to be confused in presentation as underlined in previous report. 

In flow chart  “figure 2” which is the difference between “met non inclusion criteria”  and “met exclusion criteria”. 

Answer: met non inclusion criteria means that patient do not meet the conditions to be included in the study. For example presence of an associated  chronic pathology. Met exclusion criteria means that patient was first included and finally excluded for example because of a rise in troponin.