Indoor Air Quality and Bioaerosols in Spanish University Classrooms

by
Esther Fuentes-Ferragud
1,2,
Antonio López
1,*,
Juan Miguel Piera
1,
Vicent Yusà
1,3,4,
Salvador Garrigues
4,
Miguel de la Guardia
4,
F. Xavier López Labrador
1,5,6,
Marisa Camaró
3,
María Ibáñez
2 and
Clara Coscollà
1
1
Foundation for the Promotion of Health and Biomedical Research in the Valencia Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020 Valencia, Spain
2
Environmental and Public Health Analytical Chemistry, Research Institute for Pesticides and Water, University Jaume I, S/N, Avenida Sos Baynat, 12071 Castelló de la Plana, Spain
3
Public Health Laboratory of Valencia, 21, Avenida Catalunya, 46020 Valencia, Spain
4
Analytical Chemistry Department, University of Valencia, Edifici Jeroni Muñoz, Dr. Moliner 50, 46100 Burjassot, Spain
5
Microbiology Department, University of Valencia Medical School, Av. de Blasco Ibáñez, 13, 46010 Valencia, Spain
6
CIBERESP, Institute of Health Carlos III, Sinsesio Delgado Street, 4, 28029 Madrid, Spain
*
Author to whom correspondence should be addressed.
Toxics 2024, 12(3), 227; https://doi.org/10.3390/toxics12030227
Submission received: 30 January 2024 / Revised: 13 March 2024 / Accepted: 15 March 2024 / Published: 20 March 2024

Abstract

:
A comprehensive study assessed indoor air quality parameters, focusing on relevant air pollutants such as particulate matter (PM10 and PM2.5), gaseous compounds (CO, CO2, formaldehyde, NO2) and volatile/semi-volatile organic chemicals, as well as respiratory viruses (including SARS-CoV-2), fungi and bacteria in Spanish university classrooms. Non-target screening strategies evaluated the presence of organic pollutants inside and outside the classrooms. Saliva samples from teachers and students were collected to explore correlations between respiratory viruses in the air and biological samples. Indoor results revealed the punctual exceedance of recommended guidelines for CO2, formaldehyde (HCHO), volatile organic compounds (TVOCs) and PM in the least naturally ventilated classrooms. Significant differences occurred between the classes, with the least ventilated one showing higher average concentrations of CO2, HCHO, NO2, PM10 and PM2.5. A respiratory virus (rhinovirus/enterovirus) was detected in the medium naturally ventilated classroom, although saliva samples tested negative. Suspect screening tentatively identified 65 substances indoors and over 200 outdoors, with approximately half reporting a high toxicological risk based on the Cramer rules. The study provides a comprehensive overview of indoor air quality, respiratory viruses and organic pollutants in university classrooms, highlighting the variations and potential health risks associated with ventilation differences.

1. Introduction

People spend up to 90% of their time indoors, and consequently, indoor air quality (IAQ) inside homes, offices, educational centres, healthcare facilities and other buildings is an important health determinant [1]. In the European Union (EU), indoor air pollution exposure is associated with many non-communicable diseases and an estimated 2 million deaths yearly [2]. Furthermore, inadequate IAQ has a significant impact on human comfort, productivity and effectiveness [1,3].
IAQ in buildings is the result of a complex interplay between building quality and ventilation, outdoor air quality and indoor emissions from cleaning and/or consumer products. As a result, IAQ is affected by pollutants introduced into buildings from the outside, as well as those originating indoors. The main indoor air pollutants are particulate matter (PM), chemical pollutants like nitrogen dioxide (NO2), carbon dioxide (CO2), ozone (O3), total volatile organic compounds (TVOCs) or semi-volatile organic compounds (SVOCs), as well as biological pollutants (mainly viruses, fungi, bacteria, or toxins) [4,5].
In the EU, it is estimated that almost 80% of the disease burden from indoor exposures is caused by exposure to PM2.5 [1]. Evidence suggests that indoor PM may be more bioactive than ambient particles due to the presence of endotoxins and other pro-inflammatory components in indoor particles. Air pollution derived from PM causes irritation to the eyes, nose and throat, as well as breathing difficulties [6].
Chemical products can originate from plastic products, cleaning products, electronic and electrical equipment, textiles, furniture, perfumes and personal care products. VOCs, such as formaldehyde (HCHO) and benzene, are emitted from building materials, furniture and paints and may cause significant health effects. Short-term exposure to VOCs may cause skin irritation, dizziness and nausea, whereas longer-term exposure to some VOCs can be carcinogenic [7]. Vehicle exhaust fumes from roads and nearby parking areas is a major contributor to carbon monoxide (CO) and nitrogen oxides in urban areas [8].
Exposure to bioaerosols can cause infectious, toxic or allergic diseases [9]. In fact, fungi can produce more than 300 different mycotoxins, which can have carcinogenic, immunotoxic, cytotoxic and mutagenic effects [10]. Exposure to some Gram-negative and Gram-positive bacteria, endotoxin and actinomycetes, when dispersed through the air, can cause disease by inhalation [11]. Moreover, several viruses, including SARS-CoV-2, can be transmitted through small droplets of saliva that are expelled from the mouth when coughing, sneezing, talking or breathing, as well as through aerosols [12]. The air quality in the areas containing people infected with such viruses can influence the transmission of infection [13]. Several studies have shown that small particles containing viruses can be spread up to 10 m by aerosols in indoor environments [14].
Nowadays, there is no IAQ directive guideline or standard at the EU level, although some European countries like France, Belgium or Germany have drafted national guidelines [4]. Furthermore, there are other laws and technical standards [15,16] that aim to promote the health and well-being of building occupants through increased consideration of air quality and ventilation. On the other hand, chemical legislation also has an impact on IAQ, including the Regulation on the Registration, Authorisation and Restriction of Chemicals [17] and Directive 2011/65/EU, which regulates the restriction of the use of certain hazardous substances in electrical and electronic equipment [18]. Moreover, the World Health Organisation (WHO) has published reports addressing IAQ in relation to dampness and mould [19], pollutants [20], household fuel combustion [21] and setting ambitious goals for air quality to protect public health [22].
According to the literature, only a few studies on IAQ in university environments worldwide have been published [5,23,24,25], and there is a lack of harmonisation in the way IAQ has been assessed. Overall, only CO2 has been regularly measured as a proxy indicator of IAQ.
In contrast, the aims of the present work are as follows: (i) to study IAQ in Spanish university classrooms, including the assessment of bioaerosols and SARS-CoV-2 in the air and saliva samples in the pandemic context, and (ii) to study the presence of other pollutants in indoor and outdoor environments.
This study marks the pioneering effort in assessing organic pollutants in university classrooms through non-target screening strategies alongside the examination of bioaerosols and IAQ sensors.

2. Site Characterisation and Sampling

2.1. Study Population and Site Characterisation

Studies were carried out in three different classrooms belonging to the Chemistry Faculty of the University of Valencia and the School of Technology and Experimental Science of the University Jaume I (Valencian Region, Spain), with different types of natural ventilation, taking into account their number of windows and doors. Sampling was carried out in 2021, during the reopening of Spanish public buildings in the COVID-19 pandemic, and in 2022. There were approximately 20–40 people in the assessed classrooms. The populations under study were students and teachers of the sampled classrooms. The characteristics of the studied classrooms, such as ventilation level, dimensions, classroom volume or the number of doors, are shown in Table 1.

2.2. Sampling Air Strategies

A preliminary visit to the sampled facilities was essential in order to select the most suitable sites to be studied. During the first visit, the ventilation of the classrooms, their size, geographical orientation and classroom capacity were checked. Secondly, the researchers informed the universities about the sampling strategy in order to obtain permission to carry out the sampling procedure. Finally, the research team installed the sampling equipment before classes started on the first sampling day. The field strategy used was original, and it is proposed that this applies to indoor air quality studies in educational centres.

2.2.1. Sampling for Monitoring IAQ

The physico-chemical qualities of the indoor air, CO, CO2, HCHO, NO2, PM and TVOC concentrations were measured with sensors. Additionally, temperature (°C) and relative humidity (RH %) were recorded. All these parameters were monitored using continuous sensors (Aeroqual Series 500) distributed by PCE Iberica S.L. (Tobarra, Albacete, Spain). These sensors undergo annual calibration by the supplying company. The characteristics of the employed sensors are shown in Table S1.
The measurements of these parameters were carried out on three consecutive university lecture days, from approximately 8:30 a.m. to 1:00 p.m., with measurements recorded every 10 min (logging interval) and representing the hours when the students attended classes. The sensors were placed on tripods at a height of approximately 1.5 m (the height corresponding to the student’s breathing zone) and were homogenously distributed around the classroom.

2.2.2. Sampling for Bioaerosols

Two different samplers were employed for sampling respiratory viruses, including SARS-CoV-2. The first device consisted of a Lealand pump operating at a flow rate of 10 L min−1 for 2.5 h, collecting a total volume of 1500 L coupled to a three-stage cassette, which contained a 37 mm diameter PTFE (Polytetrafluoroethylene) filter. The second piece of equipment was the MD-8 air scan sampler, which collected aerosols on gelatine filters (3 µm pore size, 80 mm diameter and soluble in water). Two MD-8 air scans were used for virus sampling, with a flow rate of 50 L min−1 for 30 min, collecting a total volume of 1500 L. They have been previously employed in indoor hospital environments for sampling MERS-coronavirus (MERS-CoV), SARS-CoV viruses [26] and SARS-CoV-2, providing good yields [27,28].
Microbiological Air Sampler SAS Super IAQ equipment (VWR, Spain) with 90 mm Petri dishes was employed for sampling bacteria and fungi. The multimode working mode was used, with a flow of 100 L min−1 for 1 min and a delay of 10 min and 5 intakes, collecting a total air volume of 500 L. Tryptic soy agar (TSA) Petri dishes were used for bacteria growth [9,29] and Sabouraud dextrose agar (SDA) was used for fungal identification [30]. Petri dishes were incubated in an oven at 25 °C for fungi (SDA) and 30 °C for bacteria (TSA) for 3–5 days.

2.2.3. Sampling Surface for Viruses

Six surface samples were collected in each classroom. On each sampling day, two samples were taken: one on the floor and another one on a student’s desk located in the middle of the classroom. A commercial kit was used to analyse the surfaces (Xpress on-Cov-Hygiene site detection kit, VWR Avantor, Barcelona, Spain) [28].

2.2.4. Sampling Indoor Air

Samples were collected using a low-volume active sampler based on an ®Aircheck Touch Pump (SKC, Fullerton, CA, USA) coupled to a sorbent tube (XAD-2 OVS®) containing a glass fibre filter (GFF), PUF (polyurethane foam) and XAD-2 resin (SKC, Fullerton, CA, USA). An airflow rate of 0.06 m3 h−1 was applied for 48 h, collecting a total volume of 2.88 m3. Three samplers were placed at the front of the classroom near the teacher’s desk. Samples were stored at −20 °C until analysis.

2.2.5. Sampling Outdoor Air

A low-volume active sampler (Digitel DPA-16) at 2.3 m3 h−1 for 48 h was employed to collect outdoor air samples (the total volume of air collected was approximately 110 m3). Samples included a glass fibre filter (to collect the particulate phase) and PUF-XAD2-PUF sorbent (to collect the gaseous phase).

2.3. Saliva Samples Collection

Saliva samples were collected from teachers and students in the context of the pandemic situation. In order to perform it properly, participants had to refrain from eating, drinking and smoking for 30 min before sampling. Furthermore, participants needed to disinfect their hands and put on gloves before collecting the biological sample.
A sterile plastic falcon tube with a 50 mL screw cap was used to collect the samples with a zip-lock bag to store the falcon tubes. Sample volumes between 3 and 5 mL were collected, avoiding bubble formation and spillage. The details of participant recruitment, saliva collection and transport to the laboratory are described in Table S2.
Biological sample collection was approved by the Scientific Ethics Committee of FISABIO (reference 1580887), as it was the formalisation of informed consent from each participant.

2.4. Statistical Analysis

Spatial comparisons were carried out using one-way ANOVA in order to know if the obtained results in the different classrooms were significantly different (p < 0.05 was considered). In positive cases, Tukey’s range test was employed to know which classroom/s showed significant differences. All calculations and statistical analysis were performed using the SPSS 22 package program and Microsoft Excel 2016.

3. Sample Treatment and Analysis

3.1. Bioaerosols Samples

Sample preparation was performed as described by López et al., 2021 [28]. Briefly, for the cassette filters, this was as follows: 900 µL of RAV1 lysis buffer (Machery-Nagel, Düren, Germany) was added to the cassette and gently shaken for two hours. Next, 750 µL was extracted, and 5 µL of human DNA was added to the samples just before the extraction as an internal control for the quality of the extraction and amplification.
Regarding the gelatine filters (MD-8 air scan sampler), filters were cut by adding 2 mL of lysis buffer RAV1 (Machery-Nagel, Düren, Germany) and 5 µL of human DNA (as internal control) to a 50 mL tube that was heated for 5 min. Then, 200 µL of the sample solution was added to 550 µL of lysis buffer RAV1 and 30 µL of proteinase K (10 mg/mL). Samples were then heated at 56 °C for 10 min.
In both cases (cassette and gelatine filters), total nucleic acids were extracted using the Nucleospin-96 RNA kit (Macherey-Negel, Düren, Germany) on an automated platform (Hamilton Starlet, Hamilton Company, Düren, Germany). The analysis of respiratory viruses in the air was performed as described by López et al., 2021 [28]. For SARS-CoV-2, the detection was performed by RT-PCR, whereas four different screening multiplexes were employed for the other 17 respiratory viruses. Disposable, sterile and RNase/DNase-free materials and equipment were used for quality control. The use of positive, negative and internal controls as a protocol for processing quality control or quality assurance protocols in each analytical batch ensured that the studied viruses were correctly analysed [28].

3.2. Saliva Samples

Sample preparation for saliva samples was performed in a BSL2+ laboratory by preparing extraction pools of five samples as follows: 200 µL of five saliva samples were mixed in the pool and it was added to a tube containing 2 mL of Nuclisens lysis buffer (BioMérieux, Lyon, France) and 30 µL of 10 mg/mL proteinase K. The mixtures were incubated at room temperature for at least 30 min to inactivate SARS-CoV-2. Thereafter, total nucleic acids were extracted using an automated silica-based method in an automated platform (Nuclisens e-Mag, BioMérieux, Lyon, France) and eluted in 50 µL. The analysis of respiratory viruses in saliva was performed in the same way as bioaerosol samples.

3.3. SARS-CoV-2 in Surfaces

The analysis of SARS-CoV-2 on surfaces was performed in situ using a commercial kit (Xpress on-Cov-Hygiene site detection kit). This specific kit detects possible specific proteins of the virus. In just fifteen minutes, it was possible to qualitatively know whether the assessed surface was positive or negative for SARS-CoV-2 [28].

3.4. Fungi and Bacteria

The analysis of fungi and bacteria was carried out using the total number of colonies observed in the Petri dishes. The concentration, expressed as Colony-Forming Units, CFUs per cubic meter, m3 was calculated by dividing the number of colonies for bacteria and fungi by the volume of air sampled. The gender identification of fungi was carried out by microscopic visualisation.

3.5. Sample Preparation and Analysis for Indoor Samples

The extraction procedure of indoor air samples was based on pressurised fluid extraction (PLE) using an ASE-350 system (Dionex, Sunnyvale, CA, USA). The solvent extraction mixture was dichloromethane/acetone (1:1) under the following conditions: oven temperature = 50 °C, heat = 5 min, static time = 5 min, pressure = 1500 psi, 3 cycles and flush = 75%. Afterward, samples were filtered and concentrated in a Turbo Vap 500 (Zymark, Idstein, Germany) to less than 10 mL and transferred to 10 mL volumetric flasks in order to adjust them to this final volume. Next, two 5 mL aliquots were taken from each sample to obtain two different extracts (one for liquid chromatography (LC) and one for gas chromatography (GC)). Finally, both extracts of each sample were evaporated until dry in a Turbo Vap 10 (Zymark, Idstein, Germany) and redissolved in 1 mL of water/methanol (70:30) for LC and in 0.5 mL of nonane for GC, both coupled to high-resolution mass spectrometry (HRMS).
For the LC-HRMS analysis, liquid chromatography was coupled to an Orbitrap ID-X Tribrid mass spectrometer (Thermo Fisher, Bremen, Germany), using a Hypersil Gold aQ column (100 mm × 2.1 mm, 1.9 µm). A mass spectrometer was employed in the positive and negative modes (ESI + and ESI −). A full scan was acquired at 120,000 FWHM, MS2 data at 15,000 FWHM and MS3 data were detected at the Ion trap (FHWM < 0.3). For GC-HRMS, a TraceGOLD TG-5MS column (30 m, 0.25 mm, 0.25 µm) was used, and the acquisition was performed in full scan mode with a resolving power of 60,000 FWHM and a mass range from 40 to 500 m/z. More information about the gradient and temperature programmes are described by López et al., 2022, and Miralles et al., 2021, respectively [31,32].

3.6. Sample Preparation and Analysis for Outdoor Samples

For the two types of samples collected (particulate phase and gaseous phase), microwave-assisted extraction (MAE) using ethyl acetate as the extracted solvent was employed, followed by an evaporation and reconstitution step, as described by Fuentes et al., 2021 [33]. Outdoor air samples were analysed using a non-target approach to identify the maximum number of organic pollutants. The analyses were performed in the same way as indoor samples, as described in Section 3.5, “Sample preparation for indoor samples”. In the analysis, quality assurance protocols were included, including process blanks, spiked blank samples, the blank sample and reagent blank.

4. Results and Discussion

The analytical results obtained in university classrooms are presented in this section. More specifically, the results are related to the following: (1) IAQ parameters; (2) SARS-CoV-2 and other respiratory viruses in the environment (air and surface), biological samples (saliva), fungi and bacteria in bioaerosol samples; and (3) non-target results from outdoor and indoor air samples.

4.1. IAQ Parameters

Overall, IAQ parameters provided average values below those recommended by the guidelines, including comfort parameters such as temperature and relative humidity (see Table 2). Nevertheless, in classroom 2 (the worst naturally ventilated one), the running concentrations of some pollutants (CO2, HCHO, PM10, PM2.5 and TVOCs) sometimes exceeded the maximum recommended values (MRV) [22,34,35,36]. This fact was probably related to the reduced natural ventilation, the large number of people in relation to the classroom volume, the reduced number of doors and windows or its location in front of a street. In classroom 1 (medium natural ventilation classroom), two of the assessed pollutants (CO2 and formaldehyde) showed a peak value higher than the MRV on one of the assessed days. On the other hand, the classroom with the highest natural ventilation (classroom 3) did not show any value higher than the recommended guidelines (see Figures S1–S26). It is also noteworthy that a slight increase was observed in all particle concentrations from day one to day three, except in the classroom with high natural ventilation.
Differences between the studied pollutants in the classrooms were carried out. Significant differences between classrooms were observed for CO2, HCHO, NO2, PM10 and PM2.5. For TVOCs and CO only (no levels were observed in two out of three classrooms), no significant differences were found. Looking more closely at the results, it was found that CO2 concentrations were higher in the lowest-ventilated classroom (classroom 2) than in classrooms 1 and 3, as an important proxy of poorer air quality. These results were probably related to the large number of people in relation to the volume of the classroom. Particulate matter (PM10 and PM2.5) levels showed significant differences between the three classrooms, with the highest levels observed in the classroom with the least naturally ventilated room. Concerning NO2, concentrations in the best natural ventilated classroom (classroom 3) were significantly lower than in classrooms 1 and 2. Figure 1 shows the obtained box plots for each pollutant in each classroom.
The CO2 concentrations determined in our study were similar to those observed in earlier studies at Spanish universities [24]. The average concentration obtained for PM10 in classroom 2 was more than two times higher than the average concentrations reported in the study carried out in 2021 [24] and more than ten times higher than the values obtained by Aldekheel et al., 2022, in the USA [23]. Concerning NO2, average concentrations were approximately five times higher than the maximum levels obtained by Rodriguez et al., 2022 [24] in Spain. Maximum concentrations measured for TVOCs in classroom 2 were two times higher than the maximum concentration detected in university classrooms in South Africa and in university libraries in Turkey [25,37].

4.2. Obtained Results for Bioaerosols in Air, Saliva and Surfaces

SARS-CoV-2 coronavirus was not detected either in the environmental matrices (air and surface) or in the biological samples (saliva). However, one respiratory virus, Human Rhinovirus/Enterovirus (HRV/ENV), was detected one day in the indoor air of classroom 1. Several factors must be taken into account to interpret these results properly. When reopening Spanish public buildings during the COVID-19 pandemic in March 2021, some preventive measures were taken into account by the University, such as no more than 40 people in classrooms with social distancing between them (1.5 m), good ventilation with open doors and windows and mandatory use of masks. Moreover, the incidence of infectious diseases in the Valencian Region was not too high at that time (100–200 new cases per day) [38]. This set of measures could explain the negative results obtained in this study for SARS-CoV-2 in environmental and biological samples. In contrast to our results, a study carried out at the University of Barcelona during the same period (the third wave of the COVID-19 Pandemic in Spain), in which nasal swabs were collected, showed that 1.6% of the students were positive for SARS-CoV-2 [39].
Regarding other respiratory viruses, one positive sample for the HRV/ENV virus was detected in the indoor air on a single day in classroom 1 (see Table S3). By contrast, in the study carried out by Lednicky et al., 2020 [40] in university classrooms in the USA, the HRV/ENV virus was not detected.
For fungal and bacteria bioaerosols, acceptable indoor concentrations were observed. Table 3 shows the results obtained for the fungi and bacteria in the classrooms. The results were lower than the recommended maximum limit of 500 CFU m−3 [41] for both bacteria and fungi.
Differences in fungi and bacteria levels obtained in the three classrooms were investigated. Concerning bacteria results, no significant differences were observed between classrooms. On the other hand, fungi results showed that levels in classroom 2 were significantly higher than the obtained results in classrooms 1 and 3 (better-ventilated classrooms). Figure 2 shows the obtained box plots for bacteria (TSA) and fungi (SBD) in the evaluated classrooms.
Bacteria concentrations obtained in the present study were higher than the detected concentrations in a university campus in Turkey during the COVID-19 lockdown [5]. On the other hand, fungi concentrations were in line with those detected in Turkey [5].
Genera identification for fungi was also carried out. Several genera of fungi were identified as Penicillium, Aspergillus, Alternaria, Cladosporium and Mucor or Rhizopus. The obtained results were in line with the fungi genera detected in university classrooms in Italy by Di Giulio et al., 2010 [42], which are quite common in indoor environments and mainly originate in outdoor environments.

4.3. Non-Target Air Sample Analysis Results

4.3.1. Indoor

Using a high confidence identification level, 65 substances were tentatively identified in the assessed university classrooms. These 65 substances were not detected in blank samples or their area or were ten or more times higher than the blank samples. According to their toxicological hazard assigned through their Cramer class, 24 were classified as high risk, 4 were classified as medium risk, and 36 were classified as low risk. The obtained results are shown in Table S4. A total of 37 substances were related to industrial activities. It is also noteworthy that some terpenes usually detected in indoor air, like beta-pinene, borneol, camphor or limonene, were detected in the present study. These results are consistent with those obtained by Villanueva et al., 2018 [43] in school areas in the central–southeastern region of Spain.
Furthermore, it is also noticeable that one pesticide (DEET) and one of its metabolites (Cyclopent-2-ene-1-carboxylic acid, 2,3-dimethyl-1-ethyl-, ethyl ester) were tentatively identified in indoor classrooms. This pesticide is currently approved by the EU as a biocide for indoor use.

4.3.2. Outdoor

After analysis of the outdoor samples, 237 compounds were tentatively identified, providing candidates with a high confidence identification level. These 237 substances were not detected in blank samples or their area or were ten or more times higher than the blank samples. According to the toxicological hazard assigned by their Cramer class, 94 substances were classified as low risk, 119 substances were classified as high risk, and 7 substances were classified as intermediate risk. The obtained results are shown in Table S5.
The identified substances were classified, taking into account their sources, common uses or applications. Most of the detected compounds (84 compounds) were related to industrial activities. A major industrial area is located less than 10 km away from one of the sampling points. Other important activities related to the identified substances were pharmaceutical activities (18) and cosmetics (10).
Among the detected substances, it is noteworthy that some authorised pesticides, like pyrimethanil, and other banned pesticides, such as bioresmethrin or carbaryl, were tentatively identified.
Overall, only two substances were tentatively identified in indoor and outdoor environments: 2-methylbenzoic acid and vanillin. Both substances originate from industrial sources.

5. Study Limitations

The assessment of classrooms was restricted, and it was only possible to study three classrooms due to the circumstances of the pandemic situation following the reopening of university classrooms. The indoor-to-outdoor ratio was not calculated, as only two substances were identified in both indoor and outdoor environments.

6. Conclusions

Efforts to improve IAQ require an integrated approach, with the development and implementation of IAQ monitoring strategies in state and private centres like universities being crucial. In this study, a new strategy to study indoor and outdoor air quality, including bioaerosols in educational centres, is proposed.
Overall, the results showed that the average values provided were below the recommended guidelines for all the pollutants assessed. Nevertheless, some differences were observed between different levels of ventilation in the classrooms, with significant differences (p < 0.05) for CO2, HCHO, NO2, PM10, PM2.5 and fungi levels in the least naturally ventilated classrooms compared to the better-ventilated classrooms.
Only one respiratory virus (rhinovirus/enterovirus) was detected in the indoor air of the assessed classrooms. Furthermore, during the third wave of the COVID-19 pandemic, students’ and teachers’ saliva was also tested, and no positive results were obtained.
Several substances were tentatively identified in the outdoor and indoor air of the studied classrooms. Some substances that are usually found in indoor environments, like terpenes or in outdoor environments, such as pesticides, were detected in the present study. Overall, about half of the assessed substances in indoor and outdoor environments were classified as high risk, according to the Cramer rules.
Consolidated data at the European level should be made available following policy frameworks that explicitly address indoor air pollution, following harmonized monitoring requirements for sampling, analysis and data interpretation for IAQ in the EU.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/toxics12030227/s1, Table S1: Sensors specifications Table S2: Field work manual; Table S3: Results of respiratory viruses in indoor air; Table S4: List of the tentatively identified substances in indoor air; Table S5: List of the tentatively identified substances in outdoor air; Figure S1: CO concentration (ppm) in classroom 1; Figure S2: CO concentration (ppm) in classroom 2; Figure S3: CO concentration (ppm) in classroom 3; Figure S4: CO2 concentration (ppm) in classroom 1; Figure S5: CO2 concentration (ppm) in classroom 2; Figure S6: CO2 concentration (ppm) in classroom 3; Figure S7: HCHO concentration (mg m−3) in classroom 1; Figure S8: HCHO concentration (mg m−3) in classroom 2; Figure S9: NO2 concentration (ppm) in classroom 1; Figure S10: NO2 concentration (ppm) in classroom 2; Figure S11: NO2 concentration (ppm) in classroom 3; Figure S12: PM10 concentration (mg m−3) in classroom 1; Figure S13: PM10 concentration (mg m−3) in classroom 2; Figure S14: PM10 concentration (mg m−3) in classroom 3; Figure S15: PM2.5 concentration (mg m−3) in classroom 1; Figure S16: PM2.5 concentration (mg m−3) in classroom 2; Figure S17: PM2.5 concentration (mg m−3) in classroom 3; Figure S18: TVOCs concentration (mg m−3) in classroom 1; Figure S19: TVOCs concentration (mg m−3) in classroom 2; Figure S20: TVOCs concentration (mg m−3) in classroom 3; Figure S21: Temperature (°C) in classroom 1; Figure S22: Temperature (°C) in classroom 2; Figure S23: Temperature (°C) in classroom 3; Figure S24: Relative Humidity (%) in classroom 1; Figure S25: Relative Humidity (%) in classroom 2; Figure S26: Relative Humidity (%) in classroom 3.

Author Contributions

Conceptualisation, V.Y. and F.X.L.L.; methodology, E.F.-F., A.L. and J.M.P.; resources, E.F.-F., A.L., J.M.P. and M.C.; writing—original draft preparation, E.F.-F.; writing—review and editing, A.L., V.Y., S.G., M.d.l.G., M.I. and C.C.; visualisation, E.F.-F., A.L. and J.M.P.; supervision, V.Y., S.G., M.d.l.G., F.X.L.L. and M.I.; funding acquisition, V.Y. and C.C. All authors have read and agreed to the published version of the manuscript.

Funding

This work is part of the AIRCOV project “Detection of SARS-CoV-2 in the indoor air of Health and Educational Centers” (UGP-21-423) financed by the “European Regional Development Funds (ERDF) Operational Programme”. Some of the analytical instruments used in this study were financed by the European Commission under the European Regional Development Fund (ERDF) Operational Programme of the Valencia Region (2014–2020).

Institutional Review Board Statement

Biological sample collection was approved by the Scientific Ethics Committee of FISABIO (reference 1580887) as it was the formalisation of an informed consent from each participant.

Informed Consent Statement

Informed consent was obtained from all subjects involved in this study.

Data Availability Statement

Data are contained within article.

Acknowledgments

The authors would like to thank the University of Valencia, Universitat Jaume I, Microbiology Area of the Public Health Laboratory of Valencia, Genomics and Health Area of FISABIO staff and Col.lecció Espanyola de Cultius Tipus (CECT) for their help in this study.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Asikainen, A.; Carrer, P.; Kephalopoulos, S.; Oliveira, E.; Wargocki, P.; Hänninen, O. Reducing burden of disease from residential indoor air exposures in Europe (HEALTHVENT project). Environ. Health 2016, 15, s35. [Google Scholar] [CrossRef] [PubMed]
  2. Eurostat. 2019. Available online: https://ec.europa.eu/eurostat/documents/2995521/9550240/3-05022019-BP-EN.pdf/f426eec4-bbff-48f0-8084-88d721fa49ef#:~:text=In%202017%2C%20more%20than%2095,those%20aged%20ten%20to%20fifteen (accessed on 8 February 2023).
  3. Yang, D.; Mak, C.M. Relationships between indoor environmental quality and environmental factors in university classrooms. Build. Environ. 2020, 186, 107331. [Google Scholar] [CrossRef]
  4. Zhang, Y.; Hopke, P.K.; Mandin, C. Handbook of Indoor Air Quality, 2nd ed.; Springer Nature: Berlin/Heidelberg, Germany, 2022; ISBN 978-981-16-7679-6. [Google Scholar] [CrossRef]
  5. Bhat, M.A.; Eraslan, F.N.; Awad, A.; Malkoç, S.; Üzmez, O.O.; Dögeroglu, T.; Gaga, E.O. Investigation of indoor and outdoor air quality in a university campus during COVID-19 lock down period. Build. Environ. 2022, 219, 109176. [Google Scholar] [CrossRef]
  6. EC; JRC. Joint Research Centre the European Commission’s in-House Science Service. Annual Report 2012. 2012. Available online: https://ec.europa.eu/jrc/sites/default/files/jrc_ar_2012_1.pdf (accessed on 12 October 2021).
  7. David, E.; Niculescu, V.C. Volatile Organic Compounds (VOCs) as Environmental Pollutants: Occurrence and Mitigation Using Nanomaterials. Int. J. Environ. Res. Public Health 2021, 18, 13147. [Google Scholar] [CrossRef] [PubMed]
  8. Gennaro, G.; Dambruoso, P.R.; Loiotile, A.D.; Di Gilio, A.; Giungato, P.; Tutino, M.; Marzocca, A.; Mazzone, A.; Palmisani, J.; Porcelli, F. Indoor air quality in schools. Environ. Chem. Lett. 2014, 12, 467–482. [Google Scholar] [CrossRef]
  9. Brągoszewska, E.; Biedroń, I.; Kozielska, B.; Pastuszka, J.S. Microbiological indoor air quality in an office building in Gliwice, Poland: Analysis of the case study. Air Qual. Atmos. Health 2018, 11, 729–740. [Google Scholar] [CrossRef]
  10. El-Sayed, R.A.; Jebur, A.B.; Kang, W.; El-Demerdash, F.M. An overview on the major mycotoxins in food products: Characteristics, toxicity, and analysis. J. Future Foods 2022, 2, 91–102. [Google Scholar] [CrossRef]
  11. Stetzenbach, L.D. Airborne infectious microogranisms. In Encyclopedia of Microbiology; Academic Press: Cambridge, MA, USA, 2009; pp. 175–182. [Google Scholar] [CrossRef]
  12. Morawska, L.; Cao, J. Airborne transmission of SARS-CoV-2: The world should face the reality. Environ. Int. 2020, 139, 105730. [Google Scholar] [CrossRef]
  13. Rodríguez-Barranco, M.; Rivas-García, L.; Quiles, J.L.; Redondo-Sánchez, D.; Aranda-Ramírez, P.; Llopis-González, J.; Sánchez Pérez, M.J.; Sánchez-González, C. The spread of SARS-CoV-2 in Spain: Hygiene habits, sociodemographic profile, mobility patterns and comorbidities. Environ. Res. 2021, 192, 110223. [Google Scholar] [CrossRef]
  14. Setti, L.; Passarini, F.; De Gennaro, G.; Barbieri, P.; Perrone, M.G.; Borelli, M.; Palmisani, J.; Di Gilio, A.; Piscitelli, P.; Miani, A. Airborne transmission route of COVID-19: Why 2 meters/6 feet of inter-personal distance could not be enough. Int. J. Environ. Res. Public Health 2020, 17, 2932. [Google Scholar] [CrossRef]
  15. EN-1506; 2007—Ventilation for Buildings—Sheet Metal Air Ducts and Fittings with Circular Cross-Section—Dimensions. 2007. Available online: https://standards.iteh.ai/catalog/standards/cen/31607322-3223-483b-ba07-2e80bca4c831/en-1506-2007 (accessed on 14 March 2024).
  16. EU. Directive 2010/31/Eu of the European Parliament and of the Council of 19 May 2010 on the Energy Performance of Buildings. 2010. Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32010L0031&from=EN (accessed on 12 October 2021).
  17. EC. REGULATION (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 Concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), Establishing a European Chemicals Agency, Amending Directive 1999/45/EC and Repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC. 2006. Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32006R1907R(01)&from=EN (accessed on 12 October 2021).
  18. EU. Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment. 2011. Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32011L0065&from=en (accessed on 12 October 2021).
  19. WHO. WHO Guidelines for Indoor Air Quality: Dampness and Mould. 2009. Available online: https://apps.who.int/iris/bitstream/handle/10665/164348/9789289041683-eng.pdf?sequence=1&isAllowed=y (accessed on 12 October 2021).
  20. WHO. WHO Guidelines for Indoor Air Quality. Selected Pollutants. 2010. Available online: http://www.euro.who.int/__data/assets/pdf_file/0009/128169/e94535.pdf (accessed on 17 June 2021).
  21. WHO. WHO Guidelines for Indoor Air Quality: Household Fuel Combustion. 2014. Available online: https://www.who.int/airpollution/guidelines/household-fuel-combustion/IAQ_HHFC_guidelines.pdf (accessed on 12 October 2021).
  22. WHO. WHO Global Air Quality Guidelines: Setting Ambitious Goals for Air Quality to Protect Public Health. 2021. Available online: https://ec.europa.eu/environment/air/quality/documents/20210923%20-%20AAQ%20Revision%20-%20Stakeholder%20Meeting%20-%20WHO%20AQ%20Guidelines.pdf (accessed on 3 November 2021).
  23. Aldekheel, M.; Altuwayjiri, A.; Tohidi, R.; Farahani, V.J.; Sioutas, C. The Role of Portable Air Purifiers and Effective Ventilation in Improving Indoor Air Quality in University Classrooms. Int. J. Environ. Res. Public Health 2022, 19, 14558. [Google Scholar] [CrossRef]
  24. Rodríguez, D.; Urbieta, I.R.; Velasco, Á.; Campano-Laborda, M.A.; Jiménez, E. Assessment of indoor air quality and risk of COVID-19 infection in Spanish secondary school and university classrooms. Build. Environ. 2022, 226, 109717. [Google Scholar] [CrossRef] [PubMed]
  25. Güneş, G.; Yalçin, N.; Çolaklar, H. Investigation of indoor air quality in university libraries in terms of gaseous and particulate pollutants in Bartin, Turkey. Environ. Monit. Assess. 2022, 194, 200–215. [Google Scholar] [CrossRef] [PubMed]
  26. Kim, S.H.; Chang, S.Y.; Sung, M.; Park, J.H.; Bin, K.H.; Lee, H.; Choi, J.P.; Choi, W.S.; Min, J.Y. Extensive Viable Middle East Respiratory Syndrome (MERS) Coronavirus Contamination in Air and Surrounding Environment in MERS Isolation Wards. Clin. Infect. Dis. 2016, 63, 363–369. [Google Scholar] [CrossRef] [PubMed]
  27. Liu, Y.; Ning, Z.; Chen, Y.; Guo, M.; Liu, Y.; Gali, N.K.; Sun, L.; Duan, Y.; Cai, J.; Westerdahl, D.; et al. Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals. Nature 2020, 582, 557–560. [Google Scholar] [CrossRef] [PubMed]
  28. López, A.; Fuentes, E.; Yusa, V.; Lopez-Labrador, F.X.; Camaró, M.; Peris-Martinez, C.; Llácer, M.; Ortolá, S.; Coscollà, C. Indoor Air Quality including Respiratory Viruses. Toxics 2021, 9, 274. [Google Scholar] [CrossRef] [PubMed]
  29. Brągoszewska, E.; Palmowska, A.; Biedroń, I. Investigation of indoor air quality in the ventilated ice rink arena. Atmos. Pollut. Res. 2020, 11, 903–908. [Google Scholar] [CrossRef]
  30. Sepahvand, A.; Salim, K.; Hoseinzadeh, E.; Jafari, K.; Khorramabadi, R.M. Indoor and Outdoor Air Fungus Bioaerosols in Khorramabad Day Care Child Centers Western of Iran. J. Environ. Dev. 2018, 5, 1077–1090. [Google Scholar] [CrossRef]
  31. López, A.; Fuentes, E.; Yusà, V.; Ibáñez, M.; Coscollà, C. Identification of Unknown Substances in Ambient Air (PM10), Profiles and Differences between Rural, Urban and Industrial Areas. Toxics 2022, 10, 220. [Google Scholar] [CrossRef]
  32. Miralles, P.; Yusà, V.; Pineda, A.; Coscollà, C. A fast and automated strategy for the identification and risk assessment of unknown substances (Ias/nias) in plastic food contact materials by gc-q-orbitrap hrms: Recycled ldpe as a proof-of-concept. Toxics 2021, 9, 283. [Google Scholar] [CrossRef]
  33. Fuentes, E.; López, A.; Ibáñez, M.; Yusà, V.; Muñoz, A.; Vera, T.; Borrás, E.; Calvete-Sogo, H.; Coscollà, C. Pesticide Inhalation Exposure of Applicators and Bystanders Using Conventional and Innovative Cropping Systems in the Valencian Region, Spain. Atmosphere 2021, 12, 631. [Google Scholar] [CrossRef]
  34. German Supreme Health Authorities. Guide values for indoor air: First update of the German risk assessment procedure (basic scheme). Communication from the Ad-hoc Working Group on Indoor Guide Values of the Indoor Air Hygiene Commission and the States’ Supreme Health Authorities. Bundesgesundheitsblatt 2012, 55, 279–290. [Google Scholar]
  35. LIFTEC. CSIC Guía Práctica: Ventilación Natural en las Aulas. 2020. Available online: https://drive.google.com/file/d/1VG03H9UPqsTBBw3qNKNmZ2PtUbfSsc6f/view (accessed on 17 June 2021).
  36. INSHT. Límite de Exposición Profesional para Agentes Químicos en España. 2021. Available online: https://www.insst.es/documents/94886/1637405/LEP+2021.pdf/3e65c9ac-0708-f262-4808-2562cc9e0134?t=1620397240887 (accessed on 12 January 2022).
  37. Mundackal, A.; Ngole-Jeme, V.M. Evaluation of indoor and outdoor air quality in university academic buildings and associated health risk. Int. J. Environ. Health Res. 2022, 32, 1076–1094. [Google Scholar] [CrossRef]
  38. Centro Nacional de Epidemiología. Curva Epidémica. 2021. Available online: https://cnecovid.isciii.es/covid19/#provincias (accessed on 18 November 2021).
  39. Videla, S.; Otero, A.; Martí, S.; Domínguez, M.A.; Fabrellas, N.; Delgado-Hito, M.P.; Cruz, I.; Tebé, C.; Vinuesa, T.; Ardila, F.; et al. Prevalence of SARS-CoV-2 Infection at the University of Barcelona during the Third COVID-19 Pandemic Wave in Spain. Int. J. Environ. Res. Public Health 2021, 18, 6526. [Google Scholar] [CrossRef] [PubMed]
  40. Lednicky, J.A.; Shankar, S.N.; Elbadry, M.A.; Gibson, J.C.; Alam, M.; Stephenson, C.J.; Eiguren-fernandez, A.; Morris, J.G.; Mavian, C.N.; Salemi, M.; et al. Collection of SARS-CoV-2 Virus from the Air of a Clinic within a University Student Health Care Center and Analyses of the Viral Genomic Sequence. Aerosol Air Qual. Res. 2020, 20, 1167–1171. [Google Scholar] [CrossRef] [PubMed]
  41. National Environmental Agency; Institute of Environmental Epidemiology; Ministry of the Environment. Guidelines for Good Indoor Air Quality in Office Premises; NEA: Singapore, 1996; p. 44. [Google Scholar]
  42. Di Giulio, M.; Grande, R.; Di Campli, E.; Di Bartolomeo, S.; Cellini, L. Indoor air quality in university environments. Environ. Monit. Assess. 2010, 170, 509–517. [Google Scholar] [CrossRef] [PubMed]
  43. Villanueva, F.; Tapia, A.; Lara, S.; Amo-Salas, M. Indoor and outdoor air concentrations of volatile organic compounds and NO2 in schools of urban, industrial and rural areas in Central-Southern Spain. Sci. Total Environ. 2018, 622–623, 222–235. [Google Scholar] [CrossRef]
Figure 1. Boxplots for the assessed pollutants in each classroom: (A) CO2 (ppm), (B) HCHO (mg m−3), (C) NO2 (ppm), (D) PM10 (mg m−3), (E) PM2.5 (mg m−3) and (F) TVOCs (ppm). Boxplots show the median, minimum and maximum values.
Figure 1. Boxplots for the assessed pollutants in each classroom: (A) CO2 (ppm), (B) HCHO (mg m−3), (C) NO2 (ppm), (D) PM10 (mg m−3), (E) PM2.5 (mg m−3) and (F) TVOCs (ppm). Boxplots show the median, minimum and maximum values.
Toxics 12 00227 g001
Figure 2. Boxplots for (A) TSA bacteria (CFU m−3), (B) SBD fungi (CFU m−3) in the assessed classrooms.
Figure 2. Boxplots for (A) TSA bacteria (CFU m−3), (B) SBD fungi (CFU m−3) in the assessed classrooms.
Toxics 12 00227 g002
Table 1. Classroom characteristics.
Table 1. Classroom characteristics.
Assessed AreaMaximum Number of StudentsVolume (m3)Natural
Ventilation
Number of DoorsOrientation
Classroom 132296.00Medium2East
Classroom 237261.89Low1North
Classroom 325349.67High2West
Table 2. IAQ parameter results.
Table 2. IAQ parameter results.
AnalytesClassroom 1Classroom 2Classroom 3
minmaxAvSDminmaxAvSDminmaxAvSDMRV
CO (ppm)00.1400.0201.820.090.3000--3.43 a
CO2 (ppm)4487425366743097058612644864351444700 b
HCHO (mg m−3)00.990.080.0801.100.160.19- 1- 1- 1- 10.37 c
NO2 (ppm)0.0510.0800.0610.0070.0560.0730.0620.0030.0500.0650.0570.0040.5 c
PM10 (mg m−3)0.0020.0280.0130.0070.0130.1900.0330.0250.0040.0110.0060.0020.045 a
PM2.5 (mg m−3)0.0010.0150.0050.0040.0030.0220.0100.0050.0020.0050.0040.0010.015 a
TVOCs (ppm)00.890.050.120.023.070.120.3600.500.070.101.32 d
RH (%)32.052.138.38.038.955.847.04.152.466.458.84.530–70 c
Temperature (°C)17.922.420.61.218.122.020.31.017.821.019.70.817–27 c
min = minimum, max= maximum, Av = average, SD = standard deviation, MRV = maximum recommended value, bold: result above the recommended value; 1 = results not available due to HCHO sensor problems; a = WHO guidelines, 2021; b = LIFTEC and CSIC, 2020; c = INSHT, 2022; d = German Supreme Health Authorities, 2012.
Table 3. Results of bacteria and fungi in the assessed university classrooms.
Table 3. Results of bacteria and fungi in the assessed university classrooms.
TSA Petri Dishes (Bacteria) (1)
ClassroomClassroom 1Classroom 2Classroom 3
Sampling DayDay 1Day 2Day 3Day 1Day 2Day 3Day 1Day 2Day 3
Colony number90706184991645111492
CFU m−3180140122168198328102228184
SBD Petri Dishes (Fungi) (2)
ClassroomClassroom 1Classroom 2Classroom 3
Sampling DayDay 1Day 2Day 3Day 1Day 2Day 3Day 1Day 2Day 3
Colony number60477090110100324352
CFU m−3120941401802202006486104
(1) Incubated at 30 °C; (2) incubated at 25 °C.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Fuentes-Ferragud, E.; López, A.; Piera, J.M.; Yusà, V.; Garrigues, S.; de la Guardia, M.; López Labrador, F.X.; Camaró, M.; Ibáñez, M.; Coscollà, C. Indoor Air Quality and Bioaerosols in Spanish University Classrooms. Toxics 2024, 12, 227. https://doi.org/10.3390/toxics12030227

AMA Style

Fuentes-Ferragud E, López A, Piera JM, Yusà V, Garrigues S, de la Guardia M, López Labrador FX, Camaró M, Ibáñez M, Coscollà C. Indoor Air Quality and Bioaerosols in Spanish University Classrooms. Toxics. 2024; 12(3):227. https://doi.org/10.3390/toxics12030227

Chicago/Turabian Style

Fuentes-Ferragud, Esther, Antonio López, Juan Miguel Piera, Vicent Yusà, Salvador Garrigues, Miguel de la Guardia, F. Xavier López Labrador, Marisa Camaró, María Ibáñez, and Clara Coscollà. 2024. "Indoor Air Quality and Bioaerosols in Spanish University Classrooms" Toxics 12, no. 3: 227. https://doi.org/10.3390/toxics12030227

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop