Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation—Invasive Insights of TTI-Dependent Cryoenergy Titration
Abstract
:1. Introduction
2. Methods
2.1. Study Population
2.2. Pre-Procedural Management
2.3. Initial Cryoballoon Pulmonary Vein Isolation Procedures
2.4. Radiofrequency Pulmonary Vein Isolation Procedure
2.5. Statistical Analysis
3. Results
3.1. Baseline Characteristics
3.2. Procedural Data
3.3. PV Reconnection Rate after Initial Cryoballoon PVI
3.4. Localization of PV Conduction Recovery
4. Discussion
4.1. Total PV Reconnection Rate
4.2. Influence of Freeze Duration and Type of PV for PV Reconnection
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Hindricks, G.; Potpara, T.; Dagres, N.; Arbelo, E.; Bax, J.J.; Blomström-Lundqvist, C.; Boriani, G.; Castella, M.; Dan, G.A.; Dilaveris, P.E.; et al. 2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the european association of cardio-thoracic surgery (EACTS). Eur. Heart. J. 2020, 42, 373–498. [Google Scholar] [CrossRef] [PubMed]
- Kuck, K.H.; Brugada, J.; Fürnkranz, A.; Metzner, A.; Ouyang, F.; Chun, K.R.; Elvan, A.; Arentz, T.; Bestehorn, K.; Pocock, S.J.; et al. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N. Engl. J. Med. 2016, 374, 2235–2245. [Google Scholar] [CrossRef]
- Andrade, J.G.; Wazni, O.M.; Kuniss, M.; Hawkins, N.M.; Deyell, M.W.; Chierchia, G.B.; Nissen, S.; Verma, A.; Wells, G.A.; Turgeon, R.D. Cryoballoon ablation as initial treatment for atrial fibrillation: JACC state-of-the-art review. J. Am. Coll. Cardiol. 2021, 78, 914–930. [Google Scholar] [CrossRef] [PubMed]
- Pott, A.; Jäck, S.; Schweizer, C.; Baumhardt, M.; Stephan, T.; Rattka, M.; Weinmann, K.; Bothner, C.; Scharnbeck, D.; Keßler, M.; et al. Atrial fibrillation ablation in heart failure patients: Improved systolic function after cryoballoon pulmonary vein isolation. ESC Heart Fail. 2020, 7, 2258–2267. [Google Scholar] [CrossRef] [PubMed]
- Pott, A.P.; Messemer, M.; Petscher, K.; Iturbe-Orbe, M.; Bothner, C.; Rottbauer, W.; Dahme, T. Clinical outcome of 2nd generation cryoballoon pulmonary vein isolation in patients over 75 years of age. J. Cardiol. 2017, 69, 24–29. [Google Scholar] [CrossRef] [PubMed]
- Metzner, A.; Reissmann, B.; Rausch, P.; Mathew, S.; Wohlmuth, P.; Tilz, R.; Rillig, A.; Lemes, C.; Deiss, S.; Heeger, C.; et al. One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circ. Arrhythm. Electrophysiol. 2014, 7, 288–292. [Google Scholar] [CrossRef]
- Chierchia, G.B.; Di Giovanni, G.; Ciconte, G.; de Asmundis, C.; Conte, G.; Sieira-Moret, J.; Rodriguez-Mañero, M.; Casado, R.; Baltogiannis, G.; Namdar, M.; et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace 2014, 16, 639–644. [Google Scholar] [CrossRef]
- Fürnkranz, A.; Bordignon, S.; Dugo, D.; Perotta, L.; Gunawardene, M.; Schulte-Hahn, B.; Nowak, B.; Schmidt, B.; Chun, J.K.R. Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J. Cardiovasc. Electrophysiol. 2014, 25, 840–844. [Google Scholar] [CrossRef]
- Heeger, C.H.; Wissner, E.; Wohlmuth, P.; Mathew, S.; Hayashi, K.; Sohns, C.; Reißmann, B.; Lemes, C.; Maurer, T.; Saguner, A.M.; et al. Bonus-freeze: Benefit or risk? two-year outcome and procedural comparison of a “bonus-freeze” and “no bonus-freeze” protocol using the second-generation cryoballoon for pulmonary vein isolation. Clin. Res. Cardiol. 2016, 105, 774–782. [Google Scholar] [CrossRef]
- Giovanni, G.D.; Wauters, K.; Chierchia, G.B.; Sieira, J.; Levinstein, M.; Conte, G.; DEAsmundis, C.; Baltogiannis, G.; Saitoh, Y.; Ciconte, G.; et al. One-year follow-up after single procedure cryoballoon ablation: A comparison between the first and second generation balloon. J. Cardiovasc. Electrophysiol. 2014, 25, 834–839. [Google Scholar] [CrossRef]
- Straube, F.; Dorwarth, U.; Schmidt, M.; Wankerl, M.; Ebersberger, U.; Hoffmann, E. Comparison of the first and second cryoballoon: High-volume single-center safety and efficacy analysis. Circ. Arrhythm. Electrophysiol. 2014, 7, 293–299. [Google Scholar] [CrossRef] [PubMed]
- Heeger, C.H.; Schuette, C.; Seitelberger, V.; Wissner, E.; Rillig, A.; Mathew, S.; Reissmann, B.; Lemes, C.; Maurer, T.; Fink, T.; et al. Time-to-effect guided pulmonary vein isolation utilizing the third-generation versus second generation cryoballoon: One year clinical success. Cardiol. J. 2018, 26, 368–374. [Google Scholar] [CrossRef] [PubMed]
- Chun, K.R.; Stich, M.; Fürnkranz, A.; Bordignon, S.; Perrotta, L.; Dugo, D.; Bologna, F.; Schmidt, B. Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-T trial. Heart Rhythm. 2017, 14, 495–500. [Google Scholar] [CrossRef] [PubMed]
- Pott, A.; Kraft, C.; Stephan, T.; Petscher, K.; Rottbauer, W.; Dahme, T. Time-to-isolation guided titration of freeze duration in 3rd generation short-tip cryoballoon pulmonary vein isolation-comparable clinical outcome and shorter procedure duration. Int. J. Cardiol. 2018, 255, 80–84. [Google Scholar] [CrossRef] [PubMed]
- Heeger, C.H.; Wissner, E.; Mathew, S.; Deiss, S.; Lemes, C.; Rillig, A.; Wohlmuth, P.; Reissmann, B.; Tilz, R.R.; Ouyang, F.; et al. Once isolated, always isolated? incidence and characteristics of pulmonary vein reconduction after second-generation cryoballoon-based pulmonary vein isolation. Circ. Arrhythm. Electrophysiol. 2015, 8, 1088–1094. [Google Scholar] [CrossRef]
- Chen, S.; Schmidt, B.; Bordignon, S.; Perrotta, L.; Bologna, F.; Chun, K.R.J. Impact of cryoballoon freeze duration on long-term durability of pulmonary vein isolation: ICE re-map study. JACC Clin. Electrophysiol. 2019, 5, 551–559. [Google Scholar] [CrossRef]
- Kuck, K.H.; Albenque, J.P.; Chun, K.J.; Fürnkranz, A.; Busch, M.; Elvan, A.; Schlüter, M.; Braegelmann, K.M.; Kueffer, F.J.; Hemingway, L.; et al. Repeat ablation for atrial fibrillation recurrence post cryoballoon or radiofrequency ablation in the FIRE AND ICE trial. Circ. Arrhythm. Electrophysiol. 2019, 12, e007247. [Google Scholar] [CrossRef]
- Aryana, A.; Singh, S.M.; Mugnai, G.; de Asmundis, C.; Kowalski, M.; Pujara, D.K.; Cohen, A.I.; Singh, S.K.; Fuenzalida, C.E.; Prager, N.; et al. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: Results of a multicenter analysis. J. Interv. Card Electrophysiol. 2016, 47, 341–348. [Google Scholar] [CrossRef]
- Wieczorek, M.; Sassani, K.; Hoeltgen, R. Comparison of pulmonary vein reconnection patterns after multielectrode phased radiofrequency- and cryoballoon ablation of atrial fibrillation. BMC Cardiovasc. Disord. 2020, 20, 197. [Google Scholar] [CrossRef]
- Miyazaki, S.; Kajiyama, T.; Watanabe, T.; Ichijo, S.; Iesaka, Y. Additional cryoapplications at the pulmonary vein antrum using a 28-mm second-generation cryoballoon: A pilot study of extra-pulmonary vein ablation. Heart Vessels. 2018, 33, 1052–1059. [Google Scholar] [CrossRef]
- Shah, S.; Xu, W.; Adelstein, E.; Voigt, A.; Saba, S.; Jain, S. Characterization of pulmonary vein reconnection post cryoballoon ablation. Indian Pacing Electrophysiol. J. 2019, 19, 129–133. [Google Scholar] [CrossRef] [PubMed]
- Nolasco, R.R.; Leon-Larios, G.; Bazzini-Carranza, D.E.; Zavaleta, E.; Calixto-Vargas, O. Reconnection sites in redo ablation after cryoballoon pulmonary vein isolation in patients with paroxysmal atrial fibrillation. Arq. Bras. Cardiol. 2021, 117, 100–105. [Google Scholar] [CrossRef] [PubMed]
- Baumhardt, M.; Pott, A. On the quest of the optimal blanking period—can we predict early arrhythmia recurrence after atrial fibrillation ablation using biomarkers? Int. J. Cardiol. 2021, 340, 34–35. [Google Scholar] [CrossRef] [PubMed]
- Schweizer, C.; Jäck, S.; Petscher, K.; Weinmann, K.; Stephan, T.; Piskorski, L.; Federle, D.; Rottbauer, W.; Dahme, T.; Pott, A. P499-Incidence of aborted freezes for safety endpoints is reduced in cryoballoon ablation utilizing time-to-isolation guided cryoenergy dosing, DGK Herztage 2018/Annual Meeting. Clin. Res. Cardiol. 2018, 107, 1. [Google Scholar] [CrossRef]
Baseline Characteristics | Total (n = 219) | Fixed Group (n = 45) | TTI Group (n = 174) | p-Value |
---|---|---|---|---|
Age [y] [mean ± SD] | 66.8 ± 10.5 | 64.8 ± 11.6 | 67.3 ± 10.2 | 0.16 |
Sex (female) [n (%)] | 108 (49%) | 18 (40%) | 90 (52%) | 0.16 |
Pers. AF [n (%)] | 103 (47%) | 15 (33%) | 88 (51%) | 0.06 |
BMI [kg/m2] [mean ± SD] | 28.8 ± 5.5 | 29.1 ± 5.4 | 28.7 ± 5.5 | 0.67 |
LAD [mm] [mean ± SD] | 45.8 ± 6.3 | 45.1 ± 6.7 | 46.0 ± 6.2 | 0.44 |
CHA2DS2-VASc [mean ± SD] | 3.2 ± 1.6 | 3.0 ± 1.6 | 3.2 ± 1.6 | 0.61 |
Congestive heart failure [n (%)] | 58 (27%) | 9 (20%) | 49 (28%) | 0.27 |
Hypertension [n (%)] | 177 (81%) | 36 (80%) | 141 (81%) | 0.88 |
Diabetes mellitus [n (%)] | 37 (17%) | 7 (16%) | 30 (17%) | 0.79 |
Stroke [n (%)] | 20 (9%) | 7 (16%) | 13 (8%) | 0.09 |
Vascular disease (%) | 71 (32%) | 14 (31%) | 57 (33%) | 0.83 |
Procedural Parameters | Total (n = 219) | Fixed Group (n = 45) | TTI Group (n = 174) | p-Value |
---|---|---|---|---|
1st ablation (Cryo) | ||||
Procedure duration [min] [mean ± SD] | 96.6 ± 34.0 | 131.5 ± 28.3 | 87.5 ± 29.3 | <0.001 |
Total freeze duration [min] [mean ± SD] | 20.6 ± 9.5 | 34.6 ± 6.5 | 17.0 ± 6.2 | <0.001 |
Number of freezes [mean ± SD] | 6.9 ± 2.4 | 9.0 ± 1.6 | 6.4 ± 2.2 | <0.001 |
2nd ablation (RF) | ||||
Procedure duration [min] [mean ± SD] | 164.4 ± 57.6 | 175.2 ± 61.0 | 161.5 ± 56.5 | 0.22 |
Total applied RF energy [min] [mean ± SD] | 17.1 ± 16.6 | 20.9 ± 19.9 | 16.1 ± 15.6 | 0.14 |
Number RF applications [mean ± SD] | 20.3 ± 41.2 | 19.2 ± 38.7 | 20.6 ± 41.9 | 0.85 |
Total PV reconnection 2nd ablation: | 310/864 (36%) | 57/179 (32%) | 253/685 (37%) | 0.21 |
LSPV | 90/205 (44%) | 18/43 (42%) | 72/162 (44%) | 0.76 |
LIPV | 52/205 (25%) | 5/43 (12%) | 47/162 (29%) | 0.02 |
LCPV | 10/14 (71%) | 1/2 (50%) | 9/12 (75%) | 0.51 |
RSPV | 85/219 (39%) | 17/45 (38%) | 68/174 (39%) | 0.87 |
RIPV | 73/219 (33 %) | 16/45 (36%) | 57/174 (33%) | 0.72 |
Mean degree of low voltage area [mean ± SD] | 1.8 ± 1.2 | 2.2 ± 1.2 | 1.8 ± 1.2 | 0.14 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Pott, A.; Baumhardt, M.; Al-Masalmeh, M.; Wolf, A.; Schiele, M.; Schweizer, C.; Bothner, C.; Aktolga, D.; Teumer, Y.; Weinmann, K.; et al. Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation—Invasive Insights of TTI-Dependent Cryoenergy Titration. J. Cardiovasc. Dev. Dis. 2022, 9, 284. https://doi.org/10.3390/jcdd9090284
Pott A, Baumhardt M, Al-Masalmeh M, Wolf A, Schiele M, Schweizer C, Bothner C, Aktolga D, Teumer Y, Weinmann K, et al. Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation—Invasive Insights of TTI-Dependent Cryoenergy Titration. Journal of Cardiovascular Development and Disease. 2022; 9(9):284. https://doi.org/10.3390/jcdd9090284
Chicago/Turabian StylePott, Alexander, Michael Baumhardt, Mohammad Al-Masalmeh, Alexander Wolf, Matthias Schiele, Christiane Schweizer, Carlo Bothner, Deniz Aktolga, Yannick Teumer, Karolina Weinmann, and et al. 2022. "Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation—Invasive Insights of TTI-Dependent Cryoenergy Titration" Journal of Cardiovascular Development and Disease 9, no. 9: 284. https://doi.org/10.3390/jcdd9090284
APA StylePott, A., Baumhardt, M., Al-Masalmeh, M., Wolf, A., Schiele, M., Schweizer, C., Bothner, C., Aktolga, D., Teumer, Y., Weinmann, K., Rottbauer, W., & Dahme, T. (2022). Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation—Invasive Insights of TTI-Dependent Cryoenergy Titration. Journal of Cardiovascular Development and Disease, 9(9), 284. https://doi.org/10.3390/jcdd9090284