Different Methods for Assessing Tooth Colour—In Vitro Study
Abstract
:1. Introduction
2. Materials and Methods
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Paravina, R.D.; Pérez, M.M.; Ghinea, R. Acceptability and perceptibility thresholds in dentistry: A comprehensive review of clinical and research applications. J. Esthet. Restor. Dent. 2019, 31, 103–112. [Google Scholar] [CrossRef]
- Dozic, A.; Voit, N.F.; Zwartser, R.; Khashayar, G.; Aartman, I. Color coverage of a newly developed system for color determination and reproduction in dentistry. J. Dent. 2010, 38, e50–e56. [Google Scholar] [CrossRef] [PubMed]
- Mounika, A.; Mandava, J.; Roopesh, B.; Karri, G. Clinical evaluation of color change and tooth sensitivity with in-office and home bleaching treatments. Indian J. Dent. Res. 2018, 29, 423–427. [Google Scholar] [CrossRef]
- Mehl, A.; Bosch, G.; Fischer, C.; Ender, A. In vivo tooth-color measurement with a new 3D intraoral scanning system in comparison to conventional digital and visual color determination methods. Int. J. Comput. Dent. 2017, 20, 343–361. [Google Scholar]
- Zafar, M.S.; Amin, F.; Fareed, M.A.; Ghabbani, H.; Riaz, S.; Khurshid, Z.; Kumar, N. Biomimetic Aspects of Restorative Dentistry Biomaterials. Biomimetics 2020, 5, 34. [Google Scholar] [CrossRef] [PubMed]
- Pan, Q.; Westland, S. Tooth color and whitening—Digital technologies. J. Dent. 2018, 74, S42–S46. [Google Scholar] [CrossRef]
- Joiner, A.; Luo, W. Tooth colour and whiteness: A review. J. Dent. 2017, 67, S3–S10. [Google Scholar] [CrossRef]
- Sampaio, C.; Gurrea, J.; Gurrea, M.; Bruguera, A.; Atria, P.; Janal, M.; Bonfante, E.; Coelho, P.; Hirata, R. Dental Shade Guide Variability for Hues B, C, and D Using Cross-Polarized Photography. Int. J. Periodontics Restor. Dent. 2018, 38, s113–s118. [Google Scholar] [CrossRef]
- Hein, S.; Modrić, D.; Westland, S.; Tomeček, M. Objective shade matching, communication, and reproduction by combining dental photography and numeric shade quantification. J. Esthet. Restor. Dent. 2021, 33, 107–117. [Google Scholar] [CrossRef] [PubMed]
- Karaman, T.; Altintas, E.; Eser, B.; Yildirim, T.T.; Oztekin, F.; Bozoglan, A. Spectrophotometric Evaluation of Anterior Maxillary Tooth Color Distribution According to Age and Gender. J. Prosthodont. 2019, 28, e96–e102. [Google Scholar] [CrossRef]
- Mahn, E.; Tortora, S.C.; Olate, B.; Cacciuttolo, F.; Kernitsky, J.; Jorquera, G. Comparison of visual analog shade matching, a digital visual method with a cross-polarized light filter, and a spectrophotometer for dental color matching. J. Prosthet. Dent. 2021, 125, 511–516. [Google Scholar] [CrossRef] [PubMed]
- Sampaio, C.S.; Atria, P.J.; Hirata, R.; Jorquera, G. Variability of color matching with different digital photography techniques and a gray reference card. J. Prosthet. Dent. 2019, 121, 333–339. [Google Scholar] [CrossRef] [PubMed]
- Yılmaz, N.; Baygin, O.; Tüzüner, T.; Turgut, S.N.; Erbek, S. Evaluation of the effect of pediatric drugs and an oral rinse on primary teeth discoloration. Dent. Med. Probl. 2022, 59, 225–231. [Google Scholar] [CrossRef]
- Liberato, W.F.; Barreto, I.C.; Costa, P.P.; de Almeida, C.C.; Pimentel, W.; Tiossi, R. A comparison between visual, intraoral scanner, and spectrophotometer shade matching: A clinical study. J. Prosthet. Dent. 2019, 121, 271–275. [Google Scholar] [CrossRef] [PubMed]
- He, W.H.; Park, C.J.; Byun, S.; Tan, D.; Lin, C.Y.; Chee, W. Evaluating the relationship between tooth color and enamel thickness, using twin flash photography, cross-polarization photography, and spectrophotometer. J. Esthet. Restor. Dent. 2020, 32, 91–101. [Google Scholar] [CrossRef] [PubMed]
- Lazar, R.; Culic, B.; Gasparik, C.; Lazar, C.; Dudea, D. The accuracy of dental shade matching using cross-polarization photography. Int. J. Comput. Dent. 2019, 22, 343–351. [Google Scholar]
- Dias, S.; Marques, D.; Silveira, J.; Corado, D.; Alves, R.; Mata, A. Determinação da cor de diferentes escalas por dois métodos espectrofotométricos-estudo in vitro. SPEMD 2017, 58, 168–174. [Google Scholar] [CrossRef]
- Ferreira Dias, S.B.; Lourenço Silveira, J.M.; Nunes Pereira, R.M.; Cardoso, A.B.; Duarte Sola Pereira da Mata, A.; da Silva Marques, D.N. CIEL*a*b* values in vita classical and vita 3d master by two dental spectrophotometers. Int. J. Prosthodont. 2021. [Google Scholar] [CrossRef]
- Farah, R.I.; Almershed, A.S.; Albahli, B.F.; Ali, S.N.A.-H. Effect of ambient lighting conditions on tooth color quantification in cross-polarized dental photography: A clinical study. J. Prosthet. Dent. 2021, 128, 776–783. [Google Scholar] [CrossRef] [PubMed]
- Ntovas, P.; Papazoglou, E. Digital selection of composite resin shade using cross polarized photography and a standardized white balance gray reference card. J. Clin. Exp. Dent. 2021, 13, 1061–1067. [Google Scholar] [CrossRef] [PubMed]
- Kim-Pusateri, S.; Brewer, J.D.; Dunford, R.G.; Wee, A.G. In vitro model to evaluate reliability and accuracy of a dental shade-matching instrument. J. Prosthet. Dent. 2007, 98, 353–358. [Google Scholar] [CrossRef]
- Hein, S.; Tapia, J.; Bazos, P. eLABor_aid: A new approach to digital shade management. Int. J. Esthet. Dent. 2017, 12, 186–202. [Google Scholar]
- Koo, T.K.; Li, M.Y. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J. Chiropr. Med. 2016, 15, 155–163. [Google Scholar] [CrossRef] [PubMed]
- Paravina, R.D.; Ghinea, R.; Herrera, L.J.; Bona, A.D.; Igiel, C.; Linninger, M.; Sakai, M.; Takahashi, H.; Tashkandi, E.; Perez, M.D.M. Color difference thresholds in dentistry. J. Esthet. Restor. Dent. 2015, 27, S1–S9. [Google Scholar] [CrossRef] [PubMed]
- Lagouvardos, P.E.; Fougia, A.G.; Diamantopoulou, S.A.; Polyzois, G.L. Repeatability and interdevice reliability of two portable color selection devices in matching and measuring tooth color. J. Prosthet. Dent. 2009, 101, 40–45. [Google Scholar] [CrossRef] [PubMed]
- Gómez-Polo, C.; Gómez-Polo, M.; De Parga, J.A.M.V.; Celemin-Viñuela, A. 3D Master Toothguide According to L*, C*, and h* Coordinates. Color Res. Appl. 2014, 40, 518–524. [Google Scholar] [CrossRef]
- Kim-Pusateri, S.; Brewer, J.D.; Davis, E.L.; Wee, A.G. Reliability and accuracy of four dental shade-matching devices. J. Prosthet. Dent. 2009, 101, 193–199. [Google Scholar] [CrossRef]
- Śmielecka, M.; Dorocka-Bobkowska, B. Comparison of two optical devices used for artificial tooth color selection. Dent. Med. Probl. 2022, 59, 249–253. [Google Scholar] [CrossRef]
VC | VM | |||
---|---|---|---|---|
ICC | CI 95% | ICC | CI 95% | |
L* | 0.984 | [0.982–0.987] | 0.990 | [0.989–0.991] |
a* | 0.972 | [0.968–0.976] | 0.991 | [0.990–0.992] |
b* | 0.983 | [0.980–0.985] | 0.993 | [0.992–0.993] |
VC | VM | |||
---|---|---|---|---|
ICC | CI 95% | ICC | CI 95% | |
L* | 0.968 | [0.964–0.973] | 0.970 | [0.967–0.973] |
a* | 0.970 | [0.965–0.974] | 0.862 | [0.848–0.875] |
b* | 0.982 | [0.979–0.984] | 0.988 | [0.987–0.990] |
VC | SS | ΔE00 SS | eLAB | ΔE00 eLAB | p | ΔE00 | |
---|---|---|---|---|---|---|---|
B1 | L* | 75.7 ± 0.4 | 0.2 ± 0.5 | 74.5 ± 1.4 | 1.1 ± 1.3 | <0.05 | 3.9 ± 0.5 |
a* | −0.9 ± 0.1 | 1.9 ± 0.3 | |||||
b* | 12.8 ± 0.1 | 12.5 ± 0.5 | |||||
A1 | L* | 76.5 ± 0.3 | 0.2 ± 0.4 | 76.7 ± 2.3 | 1.6 ± 1.3 | <0.05 | 3.7 ± 0.8 |
a* | −0.3 ± 0.1 | 2.2 ± 0.3 | |||||
b* | 14.1 ± 0.2 | 12.9 ± 0.7 | |||||
B2 | L* | 74.2 ± 0.3 | 0.2 ± 0.4 | 72.7 ± 0.7 | 0.9 ± 0.8 | <0.05 | 2.9 ± 0.5 |
a* | 0.2 ± 0.1 | 2.2 ± 0.3 | |||||
b* | 18.3 ± 0.2 | 17.4 ± 0.7 | |||||
D2 | L* | 69.7 ± 0.5 | 0.4 ± 0.5 | 67.2 ± 0.8 | 1.0 ± 0.5 | <0.05 | 5.0 ± 0.7 |
a* | 0.7 ± 0.1 | 4.2 ± 0.5 | |||||
b* | 13.3 ± 0.2 | 13.9 ± 0.8 | |||||
A2 | L* | 73.8 ± 0.5 | 0.3 ± 0.4 | 72.6 ± 0.5 | 0.7 ± 0.6 | <0.05 | 4.2 ± 0.4 |
a* | 1.1 ± 0.1 | 4.3 ± 0.3 | |||||
b* | 18.2 ± 0.2 | 18.6 ± 0.4 | |||||
C1 | L* | 70.8 ± 0.5 | 0.3 ± 0.5 | 68.9 ± 0.9 | 0.9 ± 0.5 | <0.05 | 5.1 ± 0.6 |
a* | 0.0 ± 0.1 | 3.7 ± 0.4 | |||||
b* | 13.8 ± 0.2 | 15.2 ± 0.5 | |||||
C2 | L* | 69.0 ± 0.6 | 0.7 ± 0.5 | 66.4 ± 1.3 | 1.2 ± 0.8 | <0.05 | 4.9 ± 0.9 |
a* | 1.1 ± 0.2 | 4.4 ± 0.5 | |||||
b* | 18.3 ± 0.8 | 19.9 ± 0.6 | |||||
D4 | L* | 66.9 ± 0.9 | 0.9 ± 0.4 | 66.2 ± 0.8 | 1.1 ± 1.0 | 0.750 | 3.4 ± 0.6 |
a* | 1.0 ± 0.3 | 3.6 ± 0.3 | <0.05 | ||||
b* | 19.4 ± 0.7 | 21.1 ± 0.7 | 0.734 | ||||
A3 | L* | 71.7 ± 0.7 | 0.4 ± 0.8 | 68.6 ± 1.0 | 1.2 ± 0.7 | <0.05 | 4.9 ± 0.6 |
a* | 1.8 ± 0.2 | 5.3 ± 0.5 | |||||
b* | 20.5 ± 0.4 | 21.5 ± 1.1 | |||||
D3 | L* | 68.9 ± 0.5 | 0.3 ± 0.5 | 68.3 ± 1.0 | 1.2 ± 1.1 | <0.05 | 5.0 ± 0.7 |
a* | 1.4 ± 0.1 | 5.1 ± 0.3 | |||||
b* | 17.2 ± 0.1 | 18.9 ± 0.5 | |||||
B3 | L* | 71.0 ± 0.3 | 0.3 ± 0.3 | 69.7 ± 0.8 | 0.8 ± 0.5 | <0.05 | 4.0 ± 0.5 |
a* | 1.6 ± 0.2 | 5.0 ± 0.4 | |||||
b* | 23.5 ± 0.2 | 25.2 ± 0.7 | |||||
A3.5 | L* | 68.9 ± 0.5 | 0.3 ± 0.6 | 66.0 ± 1.0 | 1.1 ± 0.7 | <0.05 | 5.8 ± 0.7 |
a* | 2.4 ± 0.1 | 7.1 ± 0.7 | |||||
b* | 23.0 ± 0.3 | 26.3 ± 1.1 | |||||
B4 | L* | 69.7 ± 0.5 | 0.8 ± 0.4 | 66.8 ± 0.9 | 0.8 ± 0.4 | <0.05 | 5.6 ± 0.7 |
a* | 2.1 ± 0.2 | 6.6 ± 0.4 | |||||
b* | 24.6 ± 1.1 | 28.2 ± 0.7 | |||||
C3 | L* | 66.4 ± 0.4 | 0.3 ± 0.5 | 62.8 ± 1.1 | 1.2 ± 0.6 | <0.05 | 5.7 ± 1.1 |
a* | 1.2 ± 0.1 | 5.6 ± 0.7 | |||||
b* | 18.9 ± 0.1 | 21.2 ± 0.7 | |||||
A4 | L* | 65.4 ± 0.6 | 0.4 ± 0.6 | 61.6 ± 1.4 | 1.2 ± 0.8 | <0.05 | 7.1 ± 0.9 |
a* | 3.2 ± 0.1 | 9.4 ± 0.5 | |||||
b* | 23.0 ± 0.1 | 26.7 ± 0.3 | |||||
C4 | L* | 61.2 ± 0.6 | 0.4 ± 0.6 | 57.0 ± 7.4 | 1.0 ± 0.5 | <0.05 | 6.6 ± 1.2 |
a* | 2.5 ± 0.2 | 7.4 ± 0.6 | |||||
b* | 19.3 ± 0.3 | 22.5 ± 1.0 | |||||
Total | 0.5 ± 0.6 | 1.1 ± 0.8 | 4.9 ± 1.7 |
VM | SS | ΔE00 SS | eLAB | ΔE00 eLAB | p | ΔE00 | |
---|---|---|---|---|---|---|---|
0M1 | L* | 81.1 ± 0.2 | 0.1 ± 0.2 | 78.0 ± 1.0 | 0.9 ± 0.6 | <0.05 | 3.3 ± 0.5 |
a* | −0.3 ± 0.1 | 0.8 ± 0.2 | |||||
b* | 6.7 ± 0.1 | 4.5 ± 0.3 | |||||
0M2 | L* | 79.8 ± 0.3 | 0.2 ± 0.2 | 7.7 ± 0.8 | 1.3 ± 2.6 | <0.05 | 3.7 ± 3.1 |
a* | −0.5 ± 0.1 | 1.6 ± 4.4 | |||||
b* | 8.0 ± 0.1 | 5.7 ± 0.4 | |||||
0M3 | L* | 79.2 ± 0.1 | 0.1 ± 0.2 | 77.2 ± 0.9 | 0.9 ± 0.7 | <0.05 | 3.3 ± 0.6 |
a* | −0.7 ± 0.0 | 0.8 ± 0.2 | |||||
b* | 9.4 ± 0.2 | 6.9 ± 0.4 | |||||
1M1 | L* | 77.5 ± 0.5 | 0.2 ± 0.6 | 74.7 ± 1.1 | 1.5 ± 2.7 | <0.05 | 3.9 ± 3.1 |
a* | −0.3 ± 0.0 | 1.8 ± 0.2 | |||||
b* | 12.3 ± 0.3 | 10.4 ± 0.3 | |||||
2M1 | L* | 72.5 ± 0.1 | 0.1 ± 0.2 | 71.0 ± 1.1 | 1.0 ± 0.7 | <0.05 | 3.4 ± 0.5 |
a* | 0.2 ± 0.1 | 2.5 ± 0.2 | |||||
b* | 13.0 ± 0.1 | 12.5 ± 0.3 | |||||
1M2 | L* | 77.2 ± 0.4 | 0.2 ± 0.6 | 75.2 ± 1.5 | 1.2 ± 0.6 | <0.05 | 3.5 ± 0.6 |
a* | −0.5 ± 0.1 | 1.6 ± 0.2 | |||||
b* | 16.8 ± 0.2 | 15.4 ± 0.3 | |||||
2L1,5 | L* | 72.7 ± 0.0 | 0.3 ± 1.4 | 70.8 ± 0.8 | 0.9 ± 0.4 | <0.05 | 4.1 ± 1.0 |
a* | −0.5 ± 0.0 | 2.4 ± 0.5 | |||||
b* | 15.7 ± 1.4 | 16.1 ± 0.7 | |||||
2R1,5 | L* | 72.2 ± 0.3 | 0.3 ± 0.2 | 70.3 ± 1.2 | 1.1 ± 0.5 | <0.05 | 3.7 ± 0.7 |
a* | 0.9 ± 0.1 | 3.4 ± 0.3 | |||||
b* | 15.1 ± 0.1 | 15.0 ± 0.5 | |||||
2M2 | L* | 71.8 ± 2.0 | 1.4 ± 1.4 | 72.0 ± 1,3 | 1.2 ± 0.6 | 0.053 | 4.0 ± 0.5 |
a* | 0.3 ± 0.4 | 3.1 ± 0.3 | 0.062 | ||||
b* | 17.0 ± 1.3 | 17.9 ± 0.6 | <0.05 | ||||
3M1 | L* | 68.1 ± 0.2 | 0.2 ± 0.2 | 66.0 ± 1.3 | 1.2 ± 0.9 | <0.05 | 4.2 ± 1.0 |
a* | 1.2 ± 0.1 | 4.1 ± 0.8 | |||||
b* | 14.2 ± 0.1 | 14.5 ± 0.5 | |||||
3L1,5 | L* | 67.0 ± 0.1 | 0.1 ± 0.3 | 65.4 ± 0.8 | 1.0 ± 0.6 | <0.05 | 4.5 ± 0.6 |
a* | 1.1 ± 0.1 | 4.6 ± 0.5 | |||||
b* | 18.3 ± 0.2 | 19.6 ± 0.7 | |||||
2R2,5 | L* | 73.4 ± 0.4 | 0.2 ± 0.5 | 71.0 ± 1.0 | 0.9 ± 0.5 | <0.05 | 4.4 ± 0.4 |
a* | 0.8 ± 0.0 | 3.9 ± 0.2 | |||||
b* | 20.9 ± 0.1 | 21.3 ± 0.3 | |||||
2L2,5 | L* | 72.3 ± 0.1 | 0.1 ± 0.5 | 71.3 ± 1.3 | 1.4 ± 0.6 | <0.05 | 4.3 ± 0.9 |
a* | −0.2 ± 0.1 | 3.1 ± 0.7 | |||||
b* | 22.4 ± 0.4 | 22.5 ± 1.5 | |||||
3R1,5 | L* | 71.8 ± 1.2 | 0.6 ± 1.4 | 66.4 ± 0.9 | 0.9 ± 0.7 | 0.448 | 7.3 ± 0.6 |
a* | 1.0 ± 0.3 | 5.5 ± 0.3 | 0.921 | ||||
b* | 15.2 ± 0.4 | 17.8 ± 0.4 | 0.161 | ||||
2M3 | L* | 73.2 ± 0.2 | 0.1 ± 0.4 | 71.8 ± 1.3 | 1.1 ± 0.6 | <0.05 | 4.2 ± 0.6 |
a* | 0.3 ± 0.1 | 3.5 ± 0.4 | |||||
b* | 22.5 ± 0.1 | 23.4 ± 0.8 | |||||
3M2 | L* | 69.2 ± 1.6 | 1.0 ± 1.1 | 67.1 ± 1.3 | 1.0 ± 0.8 | 0.111 | 4.6 ± 0.5 |
a* | 1.7 ± 0.1 | 5.0 ± 0.3 | <0.05 | ||||
b* | 20.1 ± 0.7 | 20.7 ± 0.6 | 0.652 | ||||
4M1 | L* | 65.2 ± 0.5 | 0.2 ± 0.6 | 61.0 ± 0.7 | 0.9 ± 0.9 | <0.05 | 5.9 ± 0.4 |
a* | 1.9 ± 0.1 | 5.6 ± 0.2 | |||||
b* | 15.8 ± 0.1 | 15.9 ± 0.5 | |||||
3L2,5 | L* | 68.6 ± 0.3 | 0.2 ± 0.4 | 66.9 ± 0.8 | 0.9 ± 0.5 | <0.05 | 4.8 ± 0.4 |
a* | 1.3 ± 0.1 | 5.2 ± 0.4 | |||||
b* | 23.3 ± 0.1 | 24.9 ± 0.6 | |||||
3R2,5 | L* | 70.0 ± 1.0 | 0.4 ± 1.3 | 61.1 ± 0.6 | 0.7 ± 0.5 | 0.082 | 5.5 ± 0.4 |
a* | 3.1 ± 0.2 | 6.7 ± 0.2 | <0.05 | ||||
b* | 25.2 ± 0.8 | 24.8 ± 0.5 | 0.181 | ||||
4L1,5 | L* | 64.8 ± 0.5 | 0.2 ± 0.6 | 61.9 ± 0.4 | 0.8 ± 0.5 | 0.463 | 5.3 ± 0.5 |
a* | 2.2 ± 0.1 | 6.0 ± 0.4 | <0.05 | ||||
b* | 20.1 ± 0.2 | 20.9 ± 0.8 | <0.05 | ||||
3M3 | L* | 68.5 ± 0.1 | 0.3 ± 0.4 | 66.3 ± 1.1 | 1.2 ± 0.6 | <0.05 | 4.5 ± 0.6 |
a* | 2.5 ± 0.1 | 6.0 ± 0.4 | |||||
b* | 26.0 ± 0.5 | 27.0 ± 1.0 | |||||
4R1,5 | L* | 65.0 ± 0.4 | 0.5 ± 0.5 | 61.9 ± 0.8 | 0.9 ± 0.5 | <0.05 | 5.7 ± 0.9 |
a* | 3.1 ± 0.4 | 7.3 ± 0.5 | |||||
b* | 19.6 ± 0.3 | 19.7 ± 0.8 | |||||
4M2 | L* | 65.3 ± 0.4 | 0.5 ± 0.3 | 62.3 ± 0.6 | 0.9 ± 0.5 | <0.05 | 6.2 ± 0.4 |
a* | 2.5 ± 0.3 | 7.3 ± 0.4 | |||||
b* | 20.7 ± 0.5 | 22.8 ± 1.0 | |||||
5M1 | L* | 60.1 ± 0.4 | 0.2 ± 0.5 | 55.6 ± 1.5 | 1.4 ± 0.8 | <0.05 | 6.9 ± 0.8 |
a* | 3.2 ± 0.0 | 7.7 ± 0.4 | |||||
b* | 18.3 ± 0.2 | 18.6 ± 0.3 | |||||
4L2,5 | L* | 65.6 ± 0.8 | 0.4 ± 1.1 | 61.7 ± 0.9 | 1.1 ± 0.6 | 0.494 | 6.3 ± 0.8 |
a* | 3.5 ± 0.2 | 8.0 ± 0.8 | <0.05 | ||||
b* | 27.8 ± 0.5 | 28.0 ± 1.1 | <0.05 | ||||
4R2,5 | L* | 65.4 ± 0.5 | 0.8 ± 1.0 | 61.3 ± 0.9 | 0.9 ± 0.5 | <0.05 | 6.9 ± 0.7 |
a* | 3.8 ± 0.1 | 9.0 ± 0.4 | |||||
b* | 24.5 ± 1.6 | 26.1 ± 0.8 | |||||
4M3 | L* | 66.0 ± 0.4 | 0.2 ± 0.6 | 62.2 ± 1.4 | 1.2 ± 0.7 | <0.05 | 6.9 ± 0.8 |
a* | 3.5 ± 0.1 | 9.1 ± 0.3 | |||||
b* | 28.1 ± 0.1 | 30.3 ± 1.0 | |||||
5M2 | L* | 61.2 ± 0.2 | 0.1 ± 0.4 | 57.7 ± 1.2 | 1.1 ± 0.6 | <0.05 | 6.9 ± 0.8 |
a* | 4.6 ± 0.1 | 10.1 ± 0.4 | |||||
b* | 25.1 ± 0.3 | 26.1 ± 0.5 | |||||
5M3 | L* | 62.0 ± 0.5 | 0.2 ± 0.7 | 57.9 ± 1.1 | 1.2 ± 0.7 | <0.05 | 7.9 ± 0.9 |
a* | 5.8 ± 0.1 | 12.5 ± 0.6 | |||||
b* | 32.2 ± 0.4 | 33.5 ± 0.7 | |||||
Total | 0.5 ± 0.8 | 1.1 ± 0.9 | 5.0 ± 1.7 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Dias, S.; Dias, J.; Pereira, R.; Silveira, J.; Mata, A.; Marques, D. Different Methods for Assessing Tooth Colour—In Vitro Study. Biomimetics 2023, 8, 384. https://doi.org/10.3390/biomimetics8050384
Dias S, Dias J, Pereira R, Silveira J, Mata A, Marques D. Different Methods for Assessing Tooth Colour—In Vitro Study. Biomimetics. 2023; 8(5):384. https://doi.org/10.3390/biomimetics8050384
Chicago/Turabian StyleDias, Susana, Joana Dias, Ruben Pereira, João Silveira, António Mata, and Duarte Marques. 2023. "Different Methods for Assessing Tooth Colour—In Vitro Study" Biomimetics 8, no. 5: 384. https://doi.org/10.3390/biomimetics8050384
APA StyleDias, S., Dias, J., Pereira, R., Silveira, J., Mata, A., & Marques, D. (2023). Different Methods for Assessing Tooth Colour—In Vitro Study. Biomimetics, 8(5), 384. https://doi.org/10.3390/biomimetics8050384