Next Article in Journal
Study Protocol to Determine Association between Environmental Triggers and Asthma among Children in King Williams Town
Previous Article in Journal
What’s Wrong in a Jump? Prediction and Validation of Splice Site Variants
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Submerged Bioreactor Production of Geobacillus stearothermophilus ATCC 7953 Spores for Use as Bioindicators to Validate Hydrogen Peroxide Inactivation Processes

TUM School of Life Sciences, Technical University of Munich, 85354 Freising, Germany
*
Author to whom correspondence should be addressed.
Methods Protoc. 2021, 4(3), 63; https://doi.org/10.3390/mps4030063
Submission received: 12 August 2021 / Revised: 6 September 2021 / Accepted: 7 September 2021 / Published: 10 September 2021

Abstract

In the food and pharmaceutical industries, evaluating the sterilization performance preceding aseptic production processes is of central importance. In the case of hydrogen peroxide sterilization of solid surfaces, bioindicators (BI) consisting of spores of Bacillus atrophaeus or Geobacillus stearothermophilus are used to validate the effectiveness and efficiency of the inactivation procedure. Commercial production of G. stearothermophilus is commonly performed on agar plates, where cultivation and sporulation conditions are not well-defined. Therefore, the produced BI can vary in their resistance, which in turn creates unacceptable uncertainties in the evaluation of aseptic processes. Submerged production in the bioreactor would allow more control over sporulation conditions, while reducing production time, resistance variability, and avoidance of false-positive or false-negative test results. In addition, submerged production of G. stearothermophilus so far was a challenge to achieve sufficiently high spore concentrations for BI production. This study reports on the development of a method for submerged production of G. stearothermophilus spores (pH 7.0, 57 °C, 30% pO2) that can achieve 1.6 × 107 spores/mL with a resistance against 35% H2O2 at 25 °C of D25°C,35% H2O2 = 73 s. This resistance ranks within the range of commercially available BI, making the results directly transferable to industrial applications.
Keywords: aseptic production; product safety; sterilization; validation aseptic production; product safety; sterilization; validation

Share and Cite

MDPI and ACS Style

Stier, P.; Kulozik, U. Submerged Bioreactor Production of Geobacillus stearothermophilus ATCC 7953 Spores for Use as Bioindicators to Validate Hydrogen Peroxide Inactivation Processes. Methods Protoc. 2021, 4, 63. https://doi.org/10.3390/mps4030063

AMA Style

Stier P, Kulozik U. Submerged Bioreactor Production of Geobacillus stearothermophilus ATCC 7953 Spores for Use as Bioindicators to Validate Hydrogen Peroxide Inactivation Processes. Methods and Protocols. 2021; 4(3):63. https://doi.org/10.3390/mps4030063

Chicago/Turabian Style

Stier, Philipp, and Ulrich Kulozik. 2021. "Submerged Bioreactor Production of Geobacillus stearothermophilus ATCC 7953 Spores for Use as Bioindicators to Validate Hydrogen Peroxide Inactivation Processes" Methods and Protocols 4, no. 3: 63. https://doi.org/10.3390/mps4030063

APA Style

Stier, P., & Kulozik, U. (2021). Submerged Bioreactor Production of Geobacillus stearothermophilus ATCC 7953 Spores for Use as Bioindicators to Validate Hydrogen Peroxide Inactivation Processes. Methods and Protocols, 4(3), 63. https://doi.org/10.3390/mps4030063

Article Metrics

Back to TopTop