Next Article in Journal
Non-Destructive Testing of CFRP DCB Specimens Using Active Thermography
Previous Article in Journal
Enhanced Defect Characterisation Using Pulsed Phase Thermography: The Impact of Sample Geometry and Signal-Enhancement Techniques
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Understanding and Controlling Interference in Sub-Terahertz Wave Measurements †

Department of Mechanical Engineering, Shibaura Institute of Technology, 3-7-5 Toyosu, Koto-ku, Tokyo 135-0061, Japan
*
Author to whom correspondence should be addressed.
Presented at the 18th International Workshop on Advanced Infrared Technology and Applications (AITA 2025), Kobe, Japan, 15–19 September 2025.
Proceedings 2025, 129(1), 51; https://doi.org/10.3390/proceedings2025129051
Published: 12 September 2025

Abstract

Interference caused by multiple reflections is a critical issue in transmission measurements using continuous wave (CW) terahertz and sub-terahertz radiation. This study proposes a practical method to reduce interference effects and improve the stability of transmittance measurements. By deriving analytical expressions for interference patterns under both normal and oblique incidence conditions, we demonstrate that oblique incidence simplifies the interference behavior and allows the reliable extraction of transmittance values from maximum and minimum signal intensities. Using a 95 GHz CW oscillator (Model SFD-753114-103-10SF-P1, Eravant, Torrance, CA, USA) and a 1 mm-thick PET sample, we conducted transmission measurements while varying the detector position. The derived method enabled the calculation of interference-free transmittance values that were consistent across different sample positions. This approach offers a practical technique for material characterization, especially in applications such as nondestructive testing and plastic recycling.

1. Introduction

In recent years, nondestructive testing (NDT) technologies have expanded their applicable frequency range from the mid-infrared to the far-infrared regions, including terahertz (THz) and sub-terahertz (sub-THz) waves. Notably, THz radiation can couple with whole-molecule vibrations, while sub-THz waves couple with phonon vibrations. These features make them promising for novel inspection techniques in structural health monitoring and material recycling [1].
Among various THz sources, single-frequency continuous wave (CW) oscillators—based on semiconductor devices—offer a simple and cost-effective alternative to Fourier Transform Infrared Spectroscopy (FTIR), particularly since they do not require interferometers. However, CW systems are highly susceptible to interference caused by multiple reflections, which compromises measurement stability. Addressing such interference is essential for the accurate characterization of material properties and reliable inspection [2].
This study investigates interference mitigation methods in transmission measurements using sub-THz CW devices. A practical method for transmittance measurement and associated data processing is proposed to suppress interference effects and enhance measurement reproducibility.

2. Methods

2.1. Interference in Reference Measurements

When performing reference measurements (i.e., without a sample), interference arises from reflections between the oscillator and the detector (Figure 1) [3]. The complex amplitude of the transmitted wave can be written as follows:
t = t 1 t 4 / { e x p i ϕ + r 1 r 4 e x p i ϕ }
The detected intensity T = | t | 2 is as follows:
T = t 1 2 t 4 2 1 + r 1 2 r 4 2 + 2 r 1 r 2 c o s 2 ϕ
By moving the detector, the minimum ( T m i n ) and maximum ( T m a x ) intensities can be obtained. Using these, the interference-independent product t 1 2 t 4 2 can be estimated as follows:
t 1 2 t 4 2 = T m a x 1 T m a x / T m i n 1 T m a x / T m i n + 1 2
Figure 1. Interference model for the reference measurement without a sample.
Figure 1. Interference model for the reference measurement without a sample.
Proceedings 129 00051 g001

2.2. Interference in Normal Incidence Sample Measurements

For transmittance measurements with normal incidence, multiple reflections occur at the four interfaces of the oscillator, sample, and detector. The transmitted amplitude becomes a complex sum involving the phase terms ϕ 1 , ϕ 2 , and ϕ 3 , leading to a complicated interference pattern. Due to this complexity, interference effects cannot be easily canceled using extreme values as achieved in the reference case [3,4].

2.3. Interference in Oblique Incidence Sample Measurements

To simplify the interference, measurements were performed with an oblique incidence angle (e.g., 45°) (Figure 2). In this configuration, some reflected components are redirected away from the detector, reducing the number of interfering terms. The transmission amplitude is as follows:
t = t 1 t 2 t 3 t 4 / { e x p i L + r 2 r 3 e x p i L + 2 ϕ 2 + r 1 r 4 e x p i L r 1 r 3 r 4 e x p i L 2 ϕ 2
where L = ϕ 1 + ϕ 2 + ϕ 3 . The detected intensity T = | t | 2 becomes
T = ( t 1 t 2 t 3 t 4 ) 2 / D
with
D = α + β c o s ( δ ( L ) )
Assuming r i < 1 , we approximate α 1 , allowing the interference-independent transmittance to be calculated as follows:
( t 1 t 2 t 3 t 4 ) 2 = 2 T m a x T m i n T m a x + T m i n
Figure 2. Interference model for transmission measurement of a sample under oblique incidence.
Figure 2. Interference model for transmission measurement of a sample under oblique incidence.
Proceedings 129 00051 g002

3. Transmission Measurement and Data Processing

Transmission measurements were conducted using a 95 GHz CW oscillator (Model SFD-753114-103-10SF-P1, Eravant, Torrance, CA, USA) (Figure 3). A 1 mm-thick PET plate was used as the sample, and reproducibility was evaluated at different sample positions.
The detector was motorized and moved over a 2 mm range—sufficient to capture a full interference cycle (greater than a half-wavelength). Voltage data were recorded, and the transmittance was calculated using the maximum and minimum values obtained during movement. The angle of incidence was set to 45°.

4. Results

Figure 4 shows the calculated transmittance values at various sample positions. The results confirm that the proposed method yields stable and reproducible transmittance measurements, irrespective of the sample’s position, by effectively suppressing interference.

5. Conclusions

In this study, we addressed the problem of interference in transmission measurements using sub-terahertz continuous wave radiation. We derived interference equations for both reference and sample measurements and proposed a method to eliminate interference effects by analyzing maximum and minimum voltage values. Notably, we found that using oblique incidence simplifies the interference pattern, allowing for more accurate and reproducible transmittance measurements. Experimental validation using a 1 mm PET plate and a 95 GHz oscillator confirmed that our method provides stable transmittance results, independent of sample position. These findings contribute to improving the reliability of CW-based terahertz and sub-terahertz inspection technologies and hold potential for broader application in material inspection, especially for nondestructive testing and plastic recycling.

Author Contributions

Conceptualization, T.D.; methodology, T.D.; software, T.D. and S.M.; validation, T.D.; formal analysis, T.D.; investigation, T.D.; resources, T.D.; data curation, T.D.; writing—original draft preparation, T.D.; writing—review and editing, T.D. and T.T.; visualization, T.D.; supervision, T.D. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Dataset available on request from authors.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Okubo, K.; Manago, G.; Tanabe, T.; Yu, J.; Liu, X.; Sasaki, T. Identifying plastic materials in post-consumer food containers and packaging waste using terahertz spectroscopy and machine learning. Waste Manag. 2025, 196, 32–41. [Google Scholar] [CrossRef] [PubMed]
  2. Li, C.; Zhao, C.; Ren, Y.; He, X.; Yu, X.; Song, Q. Microwave traveling-standing wave method for density-independent detection of grain moisture content. Measurement 2022, 198, 111373. [Google Scholar] [CrossRef]
  3. van de Stadt, H.; Muller, J. M. Multimirror Fabry–Perot interferometers. J. Opt. Soc. Am. A 1985, 2, 1363–1370. [Google Scholar] [CrossRef]
  4. Wang, L.; Zhou, R.; Li, M.; Li, M.-Y.; Wen, X.; Lu, H. Asymmetric Reflection Spectrum of Fabry-Perot Interferometer and the Application in Pressure Sensing. J. Light. Technol. 2022, 40, 4011–4019. [Google Scholar] [CrossRef]
Figure 3. Experimental setup for transmission measurement of plastic samples.
Figure 3. Experimental setup for transmission measurement of plastic samples.
Proceedings 129 00051 g003
Figure 4. Measured transmittance of the PET sample at each sample position.
Figure 4. Measured transmittance of the PET sample at each sample position.
Proceedings 129 00051 g004
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Date, T.; Miyazaki, S.; Tanabe, T. Understanding and Controlling Interference in Sub-Terahertz Wave Measurements. Proceedings 2025, 129, 51. https://doi.org/10.3390/proceedings2025129051

AMA Style

Date T, Miyazaki S, Tanabe T. Understanding and Controlling Interference in Sub-Terahertz Wave Measurements. Proceedings. 2025; 129(1):51. https://doi.org/10.3390/proceedings2025129051

Chicago/Turabian Style

Date, Tomoaki, Seiya Miyazaki, and Tadao Tanabe. 2025. "Understanding and Controlling Interference in Sub-Terahertz Wave Measurements" Proceedings 129, no. 1: 51. https://doi.org/10.3390/proceedings2025129051

APA Style

Date, T., Miyazaki, S., & Tanabe, T. (2025). Understanding and Controlling Interference in Sub-Terahertz Wave Measurements. Proceedings, 129(1), 51. https://doi.org/10.3390/proceedings2025129051

Article Metrics