Next Article in Journal
Non-Stoichiometric Titanium-Oxide Gate Electrodes for EGFET Based pH Sensors
Previous Article in Journal
Chordoma Treatment with Boron Neutron Capture Therapy (BNCT): Experimental Insights
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Silver-Based Plasmonic Grating with PDMS Microchannel for Biological Sensors †

1
Professorship for Sensors, Department of Electrical Engineering and Information Technology, TU Dortmund, 44227 Dortmund, Germany
2
Chair for Communication Technology, Department of Electrical Engineering and Information Technology, TU Dortmund, 44227 Dortmund, Germany
*
Author to whom correspondence should be addressed.
Presented at the XXXV EUROSENSORS Conference, Lecce, Italy, 10–13 September 2023.
Proceedings 2024, 97(1), 192; https://doi.org/10.3390/proceedings2024097192
Published: 17 April 2024

Abstract

:
The label-free approach streamlines sample analysis by eliminating the need for fluorescent markers or labels, thus improving accuracy and speed. This contribution explores the potential of silver-based plasmonic gratings as central building blocks for developing biological sensors using label-free detection techniques. It presents the design, fabrication, and optimization of plasmonic gratings, including showcasing their application in biological molecule detection.

1. Introduction

Label-free detection is widely used for studying biological molecules and offers straightforward information compared to using labeled molecules [1]. Silver-based gratings enable label-free detection in biomedical applications by exciting plasmonic surface waves [2]. Additionally, grating structures enable miniaturization, integration with established microelectronic technologies, and simple use in on-chip applications. Plasmonic research focuses on various applications, including chemical and biological sensors, optics, and data transfer. These enable real-time analyte detection through surface plasmon excitation. Grating configurations can be seamlessly combined with integrated circuit manufacturing technology, providing adaptability and accuracy in quantifying small molecule quantities in biosensors. However, the challenges include stability, durability, and fabrication processes. This work presents the development of high-performance biological sensors, harnessing the potential of silver-based plasmonic gratings with microchannel and label-free detection techniques.

2. Materials and Methods

A silver grating was fabricated on a silicon wafer with a surface of (20 × 20) mm2, a thickness of 100 nm, and a grating height of 50 nm. Electron beam lithography was used to create an 800 nm grating period within a total area of 1.2 mm2. A 5 μM solution of protein A [3] in pH 7.5 phosphate-buffered saline (PBS) buffer was measured using polydimethylsiloxane (PDMS) microchannels [4] with a thickness of 2000 μm and a channel height of 150 μm, respectively, attached to the silver grating structure. The grating plasmon excitation was measured with an angle scanning tool. The experimental setup presented in Figure 1 was used to detect the reflected wave from the grating structure, utilizing a He-Ne laser source operated at a wavelength of 632.8 nm. The sample was rotated within an angle range of 10°–45° with reflections analyzed at intervals of 0.2°.

3. Discussion

The plasmon excitation angles with and without a PDMS microchannel are depicted in Figure 2 and show similar behavior, indicating its minimal impact on detection. The results confirm PDMS as an appropriate solution-containment channel. The PBS solution shifted the excitation angle of the plasmons, and the protein A solution caused a further shift. The grating sensor with the PDMS microchannel had an average sensitivity of approximately 77.23°/RIU, demonstrating the viability of PDMS as a microchannel and the grating coupler for biomolecular solution identification.

Author Contributions

Conceptualization by P.S. and D.S.; methodology by P.S.; software by P.S.; writing by S.P. and P.S.; supervision by S.P. All authors have read and agreed to the published version of the manuscript.

Funding

P.S. appreciates funding from the Erasmus Mundus LEADERS (leading mobility between Europe and Asia in developing engineering education and research) program.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Cooper, M. (Ed.) Label-Free Biosensors: Techniques and Applications; Label-Free Biosensors; Cambridge University Press: Cambridge, UK, 2009; pp. Xi–Xii. [Google Scholar]
  2. Li, E.; Chu, H. Plasmonic biosensing devices and systems. In Plasmonic Nanoelectronics and Sensing; EuMA High Frequency Technologies Series; Cambridge University Press: Cambridge, UK, 2014; pp. 217–248. [Google Scholar]
  3. Christopoulos, T.; Diamandis, E. Immunoassay; Immunoassay Configurations; Academic Press: Cambridge, MA, USA, 1996; pp. 227–236. [Google Scholar]
  4. Raj, M.K.; Chakraborty, S. PDMS microfluidics: A mini review. J. Appl. Polym. Sci. 2020, 137, 48958. [Google Scholar] [CrossRef]
Figure 1. (a) Schematic overview of the silver grating geometry with a grating period of P = 800 nm, a height of h = 50 nm, and a thickness of b = 100 nm. (b) The silver grating with PDMS microchannel was mounted in the sample holder with laser beam alignment on the grating area. The experimental setup indicating the incident and reflected waves is shown in (c).
Figure 1. (a) Schematic overview of the silver grating geometry with a grating period of P = 800 nm, a height of h = 50 nm, and a thickness of b = 100 nm. (b) The silver grating with PDMS microchannel was mounted in the sample holder with laser beam alignment on the grating area. The experimental setup indicating the incident and reflected waves is shown in (c).
Proceedings 97 00192 g001
Figure 2. The effect of PDMS microchannel on the relative reflection and plasmon excitation angle change induced by various fluid solutions.
Figure 2. The effect of PDMS microchannel on the relative reflection and plasmon excitation angle change induced by various fluid solutions.
Proceedings 97 00192 g002
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Sarapukdee, P.; Schulz, D.; Palzer, S. Silver-Based Plasmonic Grating with PDMS Microchannel for Biological Sensors. Proceedings 2024, 97, 192. https://doi.org/10.3390/proceedings2024097192

AMA Style

Sarapukdee P, Schulz D, Palzer S. Silver-Based Plasmonic Grating with PDMS Microchannel for Biological Sensors. Proceedings. 2024; 97(1):192. https://doi.org/10.3390/proceedings2024097192

Chicago/Turabian Style

Sarapukdee, Pongsak, Dirk Schulz, and Stefan Palzer. 2024. "Silver-Based Plasmonic Grating with PDMS Microchannel for Biological Sensors" Proceedings 97, no. 1: 192. https://doi.org/10.3390/proceedings2024097192

Article Metrics

Back to TopTop