Next Article in Journal
Mid-IR Fiber-Optic Sensors
Previous Article in Journal
Electronic versus Ionic Electroactive Polymers (EAPs) Strain Sensors for Wearable Electronics: A Comparative Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Influence of the Printing Pastes’ Rheology on Screen-Printed Electrochemical Sensors’ Performance †

by
Filip Budny
1,2,
Marta Jarczewska
3,
Piotr Aureliusz Walter
1,2,
Sandra Lepak-Kuc
1,2,
Dominik Baraniecki
1,2,
Andrzej Pepłowski
1,* and
Małgorzata Jakubowska
1,2
1
Printed Electronics & Assembly Lab, Center for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, 02-822 Warsaw, Poland
2
Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, 02-525 Warsaw, Poland
3
The Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, 00-664 Warsaw, Poland
*
Author to whom correspondence should be addressed.
Presented at the 9th International Symposium on Sensor Science, Warsaw, Poland, 20–22 June 2022.
Eng. Proc. 2022, 21(1), 3; https://doi.org/10.3390/engproc2022021003
Published: 22 August 2022
(This article belongs to the Proceedings of The 9th International Symposium on Sensor Science)

Abstract

:
This study concerns printed, disposable voltammetric electrodes for bioanalytical applications. Sensing electrodes’ electrochemically active surface area was found to relate to the screen-printing pastes’ rheology and manufacturing parameters. The sensors’ response was examined for constant carbon content in the electrode material and varying additions of surfactants and solvents, as well as the forces affecting the printing process. The printing pastes employed graphene nanoplatelets with the addition of carbon black as the functional phase and various polymers (PMMA, TPU, and others) as the composite matrix. Technological parameters examined included: the pressure and movement rate during the printing cycle, screen mesh density, curing, and ozonizing time. The rheological properties determined for each paste were: static viscosity, zero viscosity, and yield stress. To estimate active surface area values, sensors were immersed in redox couple solution and employed for CV measurements at varying scan rates. Finally, the active surface area was calculated according to the transformed Randles–Sevcik equation. The results were compared to electron transfer resistance and surface roughness. Correlation analysis was performed for the above parameters. The obtained statistical relationships will allow fine-tuning of the printed sensors’ performance as well as the faster development of new applications of this technology in analytical devices.

Author Contributions

A.P.: conceptualization (literature study, theory application, formulating conclusions), methodology (defining pastes’ compositions and planning experiments), formal analysis, F.B. and P.A.W.: screen-printing, F.B. and D.B.: rheology measurements, P.A.W.: surface morphology measurements, M.J. (Marta Jarczewska): electrochemical measurements, M.J. (Marta Jarczewska): electrochemical results interpretation, S.L.-K.: pastes’ preparation and SEM imaging, M.J. (Małgorzata Jakubowska): supervision, validation, and funding acquisition, and project administration. All authors have read and agreed to the published version of the manuscript.

Funding

This research was partially funded by the National Centre for Research and Development, Poland, through the project: “Development of construction and technology for the production of miniature diagnostic devices for rapid determination of biomarkers in physiological fluids and other biological samples—ImDiag,” grant. No. POIR.04.01.04-00-0027/17. The APC was funded from the statutory funds of Warsaw University of Technology.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Budny, F.; Jarczewska, M.; Walter, P.A.; Lepak-Kuc, S.; Baraniecki, D.; Pepłowski, A.; Jakubowska, M. Influence of the Printing Pastes’ Rheology on Screen-Printed Electrochemical Sensors’ Performance. Eng. Proc. 2022, 21, 3. https://doi.org/10.3390/engproc2022021003

AMA Style

Budny F, Jarczewska M, Walter PA, Lepak-Kuc S, Baraniecki D, Pepłowski A, Jakubowska M. Influence of the Printing Pastes’ Rheology on Screen-Printed Electrochemical Sensors’ Performance. Engineering Proceedings. 2022; 21(1):3. https://doi.org/10.3390/engproc2022021003

Chicago/Turabian Style

Budny, Filip, Marta Jarczewska, Piotr Aureliusz Walter, Sandra Lepak-Kuc, Dominik Baraniecki, Andrzej Pepłowski, and Małgorzata Jakubowska. 2022. "Influence of the Printing Pastes’ Rheology on Screen-Printed Electrochemical Sensors’ Performance" Engineering Proceedings 21, no. 1: 3. https://doi.org/10.3390/engproc2022021003

Article Metrics

Back to TopTop