Abstract

:
Fuzzy logic is the most effective mathematical solution that has been presented in the last few years to deal with the problems in which imprecise and uncertain data exist. It can be defined as a generalization of classical binary logic, which admits only two logical states, true or false, by adding degrees of truth between the extreme values. Its basics were initiated by Lotfi Zadeh in the mid-1960s. However, in the last few years, a question was raised by different authors: yes, by using a fuzzy set or membership functions we can solve the problem of some kinds of uncertainties, but what is the situation in cases where the uncertainties exist in the membership function itself? To handle this situation, researchers introduce type 2 fuzzy logic. In our paper, we will introduce the design of a type 2 fuzzy logic controller to control the level in a FESTO process workstation. The mathematical model is first deduced, and after that the controller is designed. The simulation results show that the obtained controller gives very good transient characteristics for the system response work.

1. Introduction

One of the biggest problems generally facing chemical process industries (CPI) [1] is that they are very complex and accurate models are difficult, if not impossible, to obtain [2,3]. One reason for this is the nonlinear nature of most CPI problems. Another reason is the multivariable nature of control problems, since in almost all cases we need to control at least two parameters: the quantity and quality [4]. To overcome these problems, it will be helpful to apply techniques that use human judgment and experience rather than precise mathematical models, which in the major cases are deduced from the linearization of the system and simplification hypothesis. The fuzzy logic systems are capable of handling complex, nonlinear systems using simple solutions. Although they seem adequate for controlling chemical processes, since they provide solutions to incompletely defined and nonlinear processes, they are not widely used by researchers since obtaining an optimal set of fuzzy membership functions is not an easy task [5]. Another difficulty that faces the engineer when we use the fuzzy logic approach is this question: we believe that these techniques are suitable to handle uncertainties using the principle of membership degrees, but what is the situation in cases of the existence of uncertainties in the membership function itself? [6]. Different approaches are provided to deal with this situation, among them the use of what we call type 2 fuzzy logic [7]. In our work, we use a type 2 fuzzy logic controller to control the level in the FESTO MPS PA Compact Workstation [8,9]. A general description for this workstation is given in the following sections. To achieve the goal of our work, we first introduce a general description of fuzzy logic, followed by an introduction to type 2 fuzzy logic, process description and, finally, simulation and results.

2. Fuzzy Logic

2.1. Definition

The fuzzy logic tool was introduced in 1965 by Lotfi Zadeh [10,11], and is based on the concept of fuzzy sets. Fuzzy sets theory provides a mathematical tool for dealing with uncertainty. In general, fuzzy logic provides an inference structure that enables appropriate human reasoning capabilities. It is classified as an artificial intelligent tool. This is because fuzzy systems modeling, analysis, and control incorporate a certain amount of human knowledge into their components (fuzzy sets, fuzzy logic, and fuzzy rule base) [12,13]. In recent years, the number and variety of fuzzy logic applications have increased significantly. The applications range from consumer products such as cameras, camcorders, washing machines, and microwave ovens to industrial process control, medical instrumentation, decision-support systems, and portfolio selection.

2.2. Fuzzy Logic Control

Control applications are the kinds of problems for which fuzzy logic has the greatest success [14,15,16]. The basic structure of a fuzzy logic controller is shown in Figure 1.
The measurements are processed using actual sensors (exact values), and after going through the fuzzification stage they transferred to linguistic variables, and in their fuzzier form, fuzzy inferences are computed, and the result is defuzzified; that is, it is transformed back into a specific number.

3. Type 2 Fuzzy Logic

The concept of a type 2 fuzzy set was introduced by Zadeh as an extension of the concept of an ordinary fuzzy set (henceforth called a type 1 fuzzy set) [17,18], in which the antecedent or consequent membership functions are type 2 fuzzy sets. Such sets are fuzzy sets whose membership grades themselves are type 1 fuzzy sets; they are very useful in circumstances where it is difficult to determine an exact membership function for a fuzzy set. They can be used to convey the uncertainties in membership functions of type 1 sets, due to the dependence of the membership functions on available linguistic and numerical information. Linguistic information (e.g., rules from experts), in general, does not give any information about the shapes of the membership functions. When membership functions are determined or tuned based on numerical data, the uncertainty in the numerical data, e.g., noise, translates into uncertainty in the membership functions. In all such cases, information about the linguistic/numerical uncertainty can be incorporated into the type 2 framework [15]. The structure of a T2FLS (type 2 fuzzy logic system), as presented in Figure 2, is quite similar to a type 1. The only difference is that the antecedent and/or consequent sets in a T2FLS are type 2. There are five principal parts in a T2FLS: fuzzifier, rule base, inference engine, type-reducer and defuzzifier.

4. Process Description (FESTO MPS PA Compact Workstation)

The FESTO MPS PA Compact Workstation shown in Figure 3 is a laboratory stand that has been used to design different kinds of PID controllers. As we can see in the photo, the stand is composed of a pump, pipes, two tanks, different types of sensors, actuators and a PLC controller S7-300 (Siemens Aktiengesellschaft, Nuremberg, Germany) to allow the testing of different types control systems. Using an OPC server algorithm, the PLC can communicate with the MATLAB software, in which the different control algorithms are designed. The system is equipped with a graphical tool implemented using WINCC software, to supervise the process and indicate the different measurements [19,20].
The FESTO Didactic station allows the realization of such a control system as: level, pressure, temperature and flow rate; in our case, the level control loop is used. The considered loop is shown in Figure 4. The process of the level control system is realized by the pump P101, that pumps liquid from tank B101 to tank B102 and the ultrasonic sensor located on the top of the tank B102. The measurement signal transmits the value of liquid in tank B102, and the correction is realized through an actuator signal which is the voltage applied to the pump. As is shown in Figure 4, the process admits a disturbance represented by manually opening/closing the valve V102 or the valve V110.
The best model that describes the relationship between the pump voltage and output flow rate was that identified, such that it provides better values of best fit for the training and validation tests. The transfer function given by is by Equation (1):
Y ( z ) U ( z ) = 0.013402   z 1 0.013391   z 2 1 1.970562   z 1 + 0.970593   z 2

5. Simulation and Results

In this section, the designs of type 1 and type 2 fuzzy logic controllers are presented.

5.1. Simple Type 1 Fuzzy Logic Controller

The Simulink Block diagram for the simple fuzzy logic controller applied for the FESTO workstation is shown in Figure 5, such that the inputs are the error and the variation of the error, and the output is the control action for the valve.
The membership functions for the inputs and are shown in Figure 6.
Figure 7 shows the output membership functions for the control signal of the valve.
The transient response for the system is shown in Figure 8:

5.2. Type 2 Fuzzy PID Controller

The Simulink Block diagram for the type 2 fuzzy logic PID controller applied for the FESTO workstation is shown in Figure 9, such that the inputs are the error and the variation of the error and the outputs are Kp, Ki and Kd; the PID controller’s parameters.
The membership functions for the inputs are shown in Figure 10.
Figure 11, Figure 12 and Figure 13 show the output membership functions of the PID parameters.
The transient response for the system is shown in Figure 14.
The above figures (Figure 14) show that the system has a very fast response to the set point, with more precision and stability compared with the use of a simple fuzzy logic controller shown in Figure 8, the same remark for the use of simple PID control. The experimental and simulation results show that a better control in terms of robustness, speed and precision can be achieved by type 2 fuzzy logic controllers.

6. Conclusions

In this paper, we have presented the results of simulation with the two types of fuzzy control that we have studied in this work, using a simple fuzzy controller and also a fuzzy PID controller for the FESTO Process Workstation. We have seen that the type 2 fuzzy controller shows very good performance when compared with the type 1, and from the results obtained we can say that the type 2 fuzzy controller is not just an extension, but an improvement of the type 1 fuzzy controller in the simulation framework.

Author Contributions

Conceptualization, B.R. and M.E.-A.; methodology, B.R.; software, K.M. and K.W.; validation, B.R.; formal analysis, B.R.; investigation, B.R.; resources, K.M. and K.W.; data curation, B.R.; writing—original draft preparation, B.R. and M.E.-A.; writing—review and editing, B.R.; supervision; Z.Y. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Garvin, T.; Sinott, R. Chemical Engineering Design, Principles, Practice and Economics of Plant and Process Design; Elsevier: Amsterdam, The Netherlands, 2018. [Google Scholar]
  2. Bendib, R.; Bentarzi, H. Contribution to Improve the Dynamic Control of a Binary Distillation Column. Int. J. Syst. Assur. Eng. Manag. 2017, 8, 663–675. [Google Scholar] [CrossRef]
  3. Bendib, R. Optimization and Improvement of the Overall Performances of an Industrial Plant. Ph.D. Thesis, University of M’hamed Bougerra, Boumerdes, Algeria, 2017. [Google Scholar]
  4. Skogestad, S.; Postlethwaite, I. Multivariable Feedback Control: Analysis and Design; John Wiley & Sons: Hoboken, NJ, USA, 2005; ISBN 978-0-470-01167-6. [Google Scholar]
  5. Bendib, R.; Hammadi, Y.; Mazouzi, M.; Mechhoud, E. Particle Swarm Optimization for Tuning a Fuzzy Supervisory Controller Parameters (Takagi Seguno and Mamdani Engines). Alger. J. Signals Syst. 2020, 5, 92–97. [Google Scholar] [CrossRef]
  6. Castillo, O.; Castro, J.R.; Melin, P. Type-2 Fuzzy Logic Systems. In Interval Type-3 Fuzzy Systems: Theory and Design; Castillo, O., Castro, J.R., Melin, P., Eds.; Studies in Fuzziness and Soft Computing; Springer International Publishing: Cham, Switzerland, 2022; pp. 5–11. ISBN 978-3-030-96515-0. [Google Scholar]
  7. Karnik, N.N.; Mendel, J.M. Operations on Type-2 Fuzzy Sets. Fuzzy Sets Syst. 2001, 122, 327–348. [Google Scholar] [CrossRef]
  8. Koszewnik, A.; Nartowicz, T.; Pawłuszewicz, E. Fractional Order Controller to Control Pump in FESTO MPS® PA Compact Workstation. In Proceedings of the 2016 17th International Carpathian Control Conference (ICCC), High Tatras, Slovakia, 29 May–1 June 2016; pp. 364–367. [Google Scholar]
  9. Feijoo, J.D.; Chanchay, D.J.; Llanos, J.; Ortiz-Villalba, D. Advanced Controllers for Level and Temperature Process Applied to Virtual Festo MPS® PA Workstation. In Proceedings of the 2021 IEEE International Conference on Automation/XXIV Congress of the Chilean Association of Automatic Control (ICA-ACCA), Valparaíso, Chile, 22–26 March 2021; pp. 1–6. [Google Scholar]
  10. Nguyen, H.T.; Walker, C.L.; Walker, E.A. A First Course in Fuzzy Logic, 4th ed.; Chapman and Hall/CRC: Boca Raton, FL, USA, 2018; ISBN 978-1-138-58508-9. [Google Scholar]
  11. Timothy, J.R. Fuzzy Logic with Engineering Applications, 4th ed.; Wiley: Hoboken, NJ, USA, 2016; Available online: https://www.wiley.com/en-br/Fuzzy+Logic+with+Engineering+Applications%2C+4th+Edition-p-9781119235866 (accessed on 30 November 2022).
  12. Kosko, B.; Tomos, M. Fuzzy Thinking: The New Science of Fuzzy Logic; Hyperion: New York, NY, USA, 1993. [Google Scholar]
  13. Iron, I. Fuzzy Logic-Controls, Concepts, Theories and Applications Logic with Engineering Applications, 1st ed.; Dadios, E.P., Ed.; BoD–Books on Demand: Norderstedt, Germany, 2018. [Google Scholar]
  14. King, E.R. Computational Intelligence in Control Engineering; CRC Press: Boca Raton, FL, USA, 1999. [Google Scholar]
  15. Lee, C.C. Fuzzy Logic in Control Systems: Fuzzy Logic Controller. II. IEEE Trans. Syst. Man Cybern. 1990, 20, 419–435. [Google Scholar] [CrossRef]
  16. Larkin, L.I. A Fuzzy Logic Controller for Aircraft Flight Control. In Proceedings of the 23rd IEEE Conference on Decision and Control, Las Vegas, NV, USA, 12–14 December 1984; pp. 894–897. [Google Scholar]
  17. Zadeh, L.A. Fuzzy Sets. Inf. Control 1965, 8, 338–353. [Google Scholar] [CrossRef] [Green Version]
  18. Zadeh, L.A. Outline of a New Approach to the Analysis of Complex Systems and Decision Processes. IEEE. 1973. Available online: https://ieeexplore.ieee.org/document/5408575 (accessed on 30 November 2022).
  19. Sankata, B.P.; Umesh, C.P.; Kamalakanta, M. Implementation of Fuzzy-PID Controller to Liquid Level System Using LabVIEW. Available online: https://ieeexplore.ieee.org/document/6959045 (accessed on 30 November 2022).
  20. Ahmad, S.; Ali, S.; Tabasha, R. The Design and Implementation of a Fuzzy Gain-Scheduled PID Controller for the Festo MPS PA Compact Workstation Liquid Level Control. Eng. Sci. Technol. Int. J. 2020, 23, 307–315. [Google Scholar] [CrossRef]
Figure 1. Fuzzy logic controller.
Figure 1. Fuzzy logic controller.
Engproc 29 00006 g001
Figure 2. Type 2 fuzzy logic system.
Figure 2. Type 2 fuzzy logic system.
Engproc 29 00006 g002
Figure 3. Type 2 Fuzzy logic system.
Figure 3. Type 2 Fuzzy logic system.
Engproc 29 00006 g003
Figure 4. FESTO level control loop.
Figure 4. FESTO level control loop.
Engproc 29 00006 g004
Figure 5. Simple fuzzy type 1 logic diagram applied for FESTO workstation.
Figure 5. Simple fuzzy type 1 logic diagram applied for FESTO workstation.
Engproc 29 00006 g005
Figure 6. The membership functions for the inputs. (a) Error; (b) Delta error.
Figure 6. The membership functions for the inputs. (a) Error; (b) Delta error.
Engproc 29 00006 g006
Figure 7. The membership function for the control action output.
Figure 7. The membership function for the control action output.
Engproc 29 00006 g007
Figure 8. The transient response for a step input case simple FLC.
Figure 8. The transient response for a step input case simple FLC.
Engproc 29 00006 g008
Figure 9. Simulink Block for Type 2 fuzzy logic PID controller.
Figure 9. Simulink Block for Type 2 fuzzy logic PID controller.
Engproc 29 00006 g009
Figure 10. The Type 2 membership functions for the inputs. (a) Error; (b) Delta error.
Figure 10. The Type 2 membership functions for the inputs. (a) Error; (b) Delta error.
Engproc 29 00006 g010
Figure 11. The membership function for KP.
Figure 11. The membership function for KP.
Engproc 29 00006 g011
Figure 12. Ki membership function.
Figure 12. Ki membership function.
Engproc 29 00006 g012
Figure 13. Kd membership function.
Figure 13. Kd membership function.
Engproc 29 00006 g013
Figure 14. The transient response for a step input case Type 2 FLC.
Figure 14. The transient response for a step input case Type 2 FLC.
Engproc 29 00006 g014
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Riad, B.; El-Arkam, M.; Maroua, K.; Wiam, K.; Youcef, Z. Design of Type 2 Fuzzy Logic Controller for FESTO Process Workstation. Eng. Proc. 2023, 29, 6. https://doi.org/10.3390/engproc2023029006

AMA Style

Riad B, El-Arkam M, Maroua K, Wiam K, Youcef Z. Design of Type 2 Fuzzy Logic Controller for FESTO Process Workstation. Engineering Proceedings. 2023; 29(1):6. https://doi.org/10.3390/engproc2023029006

Chicago/Turabian Style

Riad, Bendib, Mechhoud El-Arkam, Kassah Maroua, Kattouche Wiam, and Zennir Youcef. 2023. "Design of Type 2 Fuzzy Logic Controller for FESTO Process Workstation" Engineering Proceedings 29, no. 1: 6. https://doi.org/10.3390/engproc2023029006

APA Style

Riad, B., El-Arkam, M., Maroua, K., Wiam, K., & Youcef, Z. (2023). Design of Type 2 Fuzzy Logic Controller for FESTO Process Workstation. Engineering Proceedings, 29(1), 6. https://doi.org/10.3390/engproc2023029006

Article Metrics

Back to TopTop