Pesticide Industry Wastewater Treatment with Photo-Fenton Process †

Department of Environmental Engineering, Dokuz Eylul University, İzmir 35390, Turkey
*
Author to whom correspondence should be addressed.
Presented at Innovations-Sustainability-Modernity-Openness Conference (ISMO’22), Bialystok, Poland, 26–27 May 2022.
Environ. Sci. Proc. 2022, 18(1), 15; https://doi.org/10.3390/environsciproc2022018015
Published: 5 September 2022
(This article belongs to the Proceedings of Innovations-Sustainability-Modernity-Openness Conference (ISMO’22))

Abstract

:
Pesticides are agricultural drugs used to combat weeds, plants, and insects that are harmful to the product and affect the efficiency during the cultivation of plants. However, pesticides are highly toxic, carcinogenic, and mutagenic, even at low concentrations and pesticides persist in nature for a long period. Pesticide manufacturing industry wastewater causes pollution problems due to the toxic components, high chemical oxygen demand (COD), biochemical oxygen demand (BOD), high total dissolved solids (TDS) and intensive color, disgusting odor, and generally low pH values. Since adequate treatment efficiency cannot be obtained with biological treatment in these wastewaters, chemical processes based on advanced oxidation methods are needed for the removal of toxicity and organic load caused by pesticide wastewater. Advanced oxidation methods are based on the formation of hydroxyl radicals (OH) and provide the conversion of toxic organic substances into harmless products. The major objective of this study was to investigate the oxidation of raw pesticide wastewater using the photo-Fenton process by using a Box-Behnken statistical experimental design and surface response methodology. In the photo-Fenton experiments, the effects of different oxidant and catalyst concentrations for COD removal at different reaction times were investigated using Box-Behnken statistical design. Because of the studies, the most appropriate reaction conditions according to COD removal are: H2O2 concentration of 1000 mg/L, Fe+2 concentration of 325 mg/L, reaction time of 35 min, and COD yield of 70%.

1. Introduction

Pesticides are agricultural drugs used to combat weeds, plants, and insects that are harmful to the product and affect the efficiency during the cultivation of plants. They are often used in modern agriculture to meet the nutrition needs of the growing population and to obtain more products. However, pesticides are highly toxic, carcinogenic, and mutagenic, even at low concentrations and pesticides persist in nature for a long period.
Pesticide manufacturing industry wastewater causes pollution problems due to its toxic components, high chemical oxygen demand (COD), biochemical oxygen demand (BOD), high total dissolved solids (TDS) and intensive color, disgusting odor, and generally low pH values [1]. The chemical oxidation demand of pesticide wastewater is higher than the biological oxidation demand of it. Therefore, microorganisms could not easily degrade wastewater originating from the pesticide industry. Despite the low economic cost aspect of biological treatment, conventional biological methods have not been effective methods for treating or degrading refractory and toxic organics in pesticide wastewaters. Additionally, the pH value of pesticide wastewater is very low and this pH value cannot be suitable for the biological treatment process. Thus, pesticide wastewater could not be treated by biological processes directly. It is not feasible to use a single conventional biological method or conventional chemical-precipitation methods for treating pesticide wastewater.
New technologies need to develop for the effective treatment of pesticide-containing wastewaters. Depending on highly concentrated and refractory compounds in pesticide wastewater, an advanced oxidation process should be preferred as a pretreatment process before biological treatment methods to treat or degrade non-biodegradable pesticides in wastewater. Recently, advanced oxidation processes (AOPs) have been used as potentially powerful methods capable of transforming non-biodegradable pollutants into harmless substances. Almost all AOPs rely on the generation of reactive free radicals, such as the hydroxyl, OH with a redox potential of 2.8 V. Therefore, advanced oxidation is a promising alternative for the mineralization and reducing recalcitrant organic compounds in wastewaters. Photo-Fenton process as an advanced oxidation process is a very effective method to degrade pesticides in wastewater and to change the form of compounds, to convert easily degraded forms for microorganisms in biological treatment methods [2]. Additionally, the photo-Fenton process has many advantages that it requires a short reaction time and a low number of oxidant and catalyst doses compared to other advanced oxidation methods.
The major objective of this study was to investigate the advanced oxidation of pesticide wastewaters using the photo-Fenton process as a pretreatment process. The effects of hydrogen peroxide (H2O2) and ferrous ion (Fe+2) concentrations and reaction times on the oxidation of pesticide wastewater were investigated with chemical oxidation demand (COD) removal by using a Box-Behnken statistical experimental design and surface response methodology.

2. Materials and Methods

The pesticide wastewater used in these experiments, was obtained from a pesticide factory in İzmir, Turkey. This factory produced many kinds of pesticides, such as azoxytrubin, imidacloprid, epoxinazole, and methoxy fenozide. The wastewater from the pesticide production industry, which contains many precursor chemicals and pesticides, was complicated. The COD concentration of the wastewater is around 150,000 mg/L. The pH value of the wastewater was around 5. Additionally, suspended solids are very high. Photo-Fenton experiments were carried out at room temperature (23 ± 2 °C) using different hydrogen peroxide and ferrous ions. Hydrogen peroxide solution (35% w/w) and ferrous sulfate obtained from Merck were used as an oxidant and catalyst, respectively.

2.1. Design of the Experiments

The effects of variables on the response were complicated and were observed by using the most known approach, which is altering one factor at a time for multivariable systems. However, this technique is not usable for the estimation of responses. Thus, some experimental stable design should be used for the optimization of the reaction conditions. To this aim, several significant parameters are determined by response surface methodology (RSM). Among all RSM designs, the Box-Behnken design needs fewer experimental runs and allows and shows efficiency at intermediate levels not experimentally studied [3,4].

2.2. Experimental Procedure

All batch photo-oxidation experiments were performed in a completely mixed, batch, cylindrical photochemical reactor containing a 16 W low-pressure mercury vapor lamp with a total volume of 2.2 L. A diagram of the laboratory-scale photochemical reactor used in an oxidation experiment was given in previous studies [5]. In the experiments, the effects of hydrogen peroxide (H2O2) and ferrous ion (Fe+2) concentrations and reaction times as independent variables on the oxidation of raw pesticide wastewater were evaluated in terms of chemical oxidation demand (COD) removal as dependent variables in Box-Behnken design.

3. Results and Discussion

Box-Behnken design approach was mentioned as an effective and useful method for optimization of the three variable response functions, predicting the response of the fitted model by the ANOVA tests. Reaction conditions for an independent variable; H2O2 concentration was 1000–5000 mg/L (X1), Fe+2 concentration was 100–500 mg/L (X2), and reaction time was determined as 5–60 minutes (X3). The experimental conditions of the Box-Behnken experiment design and results of the Photo-Fenton processes are presented in Table 1.
This static design was preferred because of fewer combinations of the independent variables to estimate the second-order polynomial regression model. Coefficients in the regression model were determined by means of 15 runs. Nine coefficients were calculated such as one block term, three linear terms, three quadratic terms, and three interaction terms. The objective function for COD removal efficiency with the determined coefficient is presented in Equation (1).
Y1 = 86.44 − 0.03X1 + 0.13X2 − 0.39X3 + 1.0 × 10−3X1X2 + 1.0 × 10−4X1X3 + 0.0014X2X3 − 3.54 × 10−6X12 − 0.0003X22 − 0.003X32   (R-Squared = 0.99231)
Response functions with determined coefficients were used to estimate variations in response functions with the independent variables under different conditions. Figure 1 shows the effect of different Fe+2 concentrations and different reaction times ions on percent COD removal at when the initial concentration of H2O2 1000 mg/L. As shown in Figure 1, percent COD removal were 58, 65, and 48% when Fe+2 concentrations of 100, 300, and 500 mg/L, respectively, at an H2O2 concentration of 1000 mg/L and reaction time of 5 min.

4. Conclusions

Real pesticide wastewater treatment with the photo-Fenton process as a pretreatment process was investigated. The effects of hydrogen peroxide (H2O2) and ferrous ion (Fe+2) concentrations and reaction times as independent variables on the oxidation of raw pesticide wastewater were evaluated in terms of chemical oxidation demand (COD) removal as dependent variables in the Box-Behnken design. The optimal H2O2/Fe+2/reaction time ratio resulting in the maximum COD (70%) removal was found to be 1000/325/35. Optimal values of the operating parameters maximizing COD removal were determined. Additionally, at these operating parameters, TOC and suspended solid removals were also observed as 20% and 32.5%, respectively. After the photo-Fenton process as a pretreatment process, treated pesticide wastewater characterization was converted to treatment with a biological treatment method. Therefore, the aim of the research succeeded.

Author Contributions

E.Ç. and S.E. carried out experiments together, E.Ç. wrote the paper. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Singare, P.; Dhabarde, S. Pollution Scenario due to Discharge of Effluent from Agrochemicals and Pesticides Manufacturing Industries of Dombivali Industrial Belt of Mumbai, India. Int. Lett. Chem. Phys. Astron. 2016, 22, 8–15. [Google Scholar] [CrossRef]
  2. Catalkaya, E.C.; Kargi, F. Advanced oxidation treatment of pulp mill effluent for TOC and toxicity removals. J. Environ. Manag. 2008, 87, 396–404. [Google Scholar] [CrossRef]
  3. Sastry, S.V.; Khan, M.A. Aqueous based polymeric dispersion: Plackett- Burman design for screening of formulation variables of atenolol gastrointestinal therapeutic system. Pharm. Acta Helv. 1998, 73, 105–112. [Google Scholar] [CrossRef] [PubMed]
  4. Hamed, E.; Sakr, A. Application of multiple response optimization technique to extended release formulations design. J. Control. Release 2001, 73, 329–338. [Google Scholar] [CrossRef] [PubMed]
  5. Çokay, E. Effects of the heterogeneous photo-Fenton oxidation and sulfate radical-based oxidation on atrazine degradation. Desalin. Water Treat. 2022, 252, 233–242. [Google Scholar] [CrossRef]
Figure 1. COD removal efficiencies were achieved with different Fe+2 concentrations and reaction times (H2O2: 1000 mg/L, pH: 5).
Figure 1. COD removal efficiencies were achieved with different Fe+2 concentrations and reaction times (H2O2: 1000 mg/L, pH: 5).
Environsciproc 18 00015 g001
Table 1. COD Removal efficiencies as dependent variables in Box-Behnken design.
Table 1. COD Removal efficiencies as dependent variables in Box-Behnken design.
RunH2O2 (mg/L); X1Fe+2 (mg/L); X2Reaction Time (min); X3COD Rem. Eff. (%); Y1
1100010032.561.6
2500010032.542.4
3100050032.555.2
4500050032.552
51000300570
65000300548.8
710003006068
850003006068
93000100542.2
103000500527
1130001006030
1230005006045.6
13300030032.552
14300030032.552
15300030032.552
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Çokay, E.; Eker, S. Pesticide Industry Wastewater Treatment with Photo-Fenton Process. Environ. Sci. Proc. 2022, 18, 15. https://doi.org/10.3390/environsciproc2022018015

AMA Style

Çokay E, Eker S. Pesticide Industry Wastewater Treatment with Photo-Fenton Process. Environmental Sciences Proceedings. 2022; 18(1):15. https://doi.org/10.3390/environsciproc2022018015

Chicago/Turabian Style

Çokay, Ebru, and Serkan Eker. 2022. "Pesticide Industry Wastewater Treatment with Photo-Fenton Process" Environmental Sciences Proceedings 18, no. 1: 15. https://doi.org/10.3390/environsciproc2022018015

APA Style

Çokay, E., & Eker, S. (2022). Pesticide Industry Wastewater Treatment with Photo-Fenton Process. Environmental Sciences Proceedings, 18(1), 15. https://doi.org/10.3390/environsciproc2022018015

Article Metrics

Back to TopTop