Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = ECG M-Trace Base II

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 2088 KB  
Article
The Use of Samsung Health and ECG M-Trace Base II Applications for the Assessment of Exercise Tolerance in the Secondary Prevention in Patients after Ischemic Stroke
by Mateusz Lucki, Ewa Chlebuś, Agnieszka Wareńczak and Przemysław Lisiński
Int. J. Environ. Res. Public Health 2021, 18(11), 5753; https://doi.org/10.3390/ijerph18115753 - 27 May 2021
Cited by 1 | Viewed by 2931
Abstract
Background and objectives: The aim of the study was to use the mobile application Samsung Health for the assessment of parameters of exercise tolerance and the ECG (electrocardiogram) M-Trace Base II for the assessment of cardiological parameters. Materials and Methods: The [...] Read more.
Background and objectives: The aim of the study was to use the mobile application Samsung Health for the assessment of parameters of exercise tolerance and the ECG (electrocardiogram) M-Trace Base II for the assessment of cardiological parameters. Materials and Methods: The measurements were conducted during rest and after performing SMWT (Six Minute Walk Test) and SCT (Stair Climb Test) in 26 patients after ischemic stroke (IS) and 26 healthy individuals. Results: In the SMWT, the post-stroke group (SG) walked a shorter distance (p < 0.001), achieving lower mean gait velocity (p < 0.001) and lower maximum gait velocity (p = 0.002). In the SCT, SG achieved a lower mean gait velocity (p < 0.001) and lower maximum gait velocity (p < 0.001) when compared to the control group (CG). In SG, myocardial ischemia in ECG was noted in four patients after SMWT and in three patients following SCT. Both in SG and in CG the increase in SBP (systolic blood pressure) value measured after SMWT and SCT compared to at rest (p < 0.001) was observed. In SG, in the compared ratios rest to SMWT and SCT as well as SMWT to SCT, there was an increase in HR (heart rate) (p < 0.001). Conclusions: ECG M-Trace Base II and Samsung Health are mobile applications that can assess cardiological parameters and exercise tolerance parameters in patients after IS, so they can be used to plan the intensity of exercise in rehabilitation programs. Full article
(This article belongs to the Special Issue Innovative Technologies and Applications in Rehabilitation Medicine)
Show Figures

Figure 1

Back to TopTop