Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (7)

Search Parameters:
Keywords = Symfony

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
9 pages, 206 KB  
Article
Effect of Prior Laser-Assisted In Situ Keratomileusis on the Calibration Accuracy of Extended Depth of Focus Intraocular Lenses: A Direct Comparative Study
by I-Hung Lin, Chen-Cheng Chao and Chao-Kai Chang
J. Pers. Med. 2025, 15(7), 301; https://doi.org/10.3390/jpm15070301 - 10 Jul 2025
Viewed by 432
Abstract
Background: Personalized precision medicine has become a prevailing trend and applies to the selection of intraocular lenses (IOLs) for cataract surgery based on the unique corneal morphology of each person. The choice of presbyopia-correcting IOLs for post-laser-assisted in situ keratomileusis (LASIK) cataract surgery [...] Read more.
Background: Personalized precision medicine has become a prevailing trend and applies to the selection of intraocular lenses (IOLs) for cataract surgery based on the unique corneal morphology of each person. The choice of presbyopia-correcting IOLs for post-laser-assisted in situ keratomileusis (LASIK) cataract surgery is a significant concern. However, few direct comparison studies exist between eyes with and without LASIK history. We analyzed the performance of extended depth of focus (EDOF) IOL implantation in these two groups. Methods: In this retrospective single-center study, we included patients with or without previous LASIK who underwent cataract surgery and EDOF Symfony IOL implantation, with ≥1 follow up. All patients underwent optical biometry using the IOLMaster. IOL power was calculated using the Sanders Retzslaff Kraff/theoretical and Haigis-L formulas for patients without and with LASIK, respectively. Uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), refraction, and corneal tomography were recorded. The prediction error was the absolute difference between the postoperative sphere and target refraction. The right eyes of patients who met the inclusion criteria were selected for analysis. Results: Among the 321 recruited eyes, 18 underwent previous LASIK. After 1:3 age/sex matching, 17 LASIK and 49 non-LASIK eyes from 66 patients were analyzed. No significant preoperative differences existed in target refraction, spherical equivalent, or best-corrected visual acuity. All surgical procedures were uneventful. LASIK exhibited non-inferiority to non-LASIK for predictive refraction error and UNVA. An age/sex-matched regression analysis indicated no UDVA superiority between the two groups. Conclusions: Previous LASIK may have no discernible effect on the visual performance of presbyopia-correcting EDOF IOLs with respect to the absolute refractive error, UNVA, and UDVA. Longer follow-up and larger-scale studies are required to further validate these results. Full article
9 pages, 1386 KB  
Article
Comparative Evaluation of Visual Performance and Patient Satisfaction following Cataract Surgery: A Retrospective Analysis of an Extended Depth-of-Focus Intraocular Lens and a Diffractive Multifocal Lens with Extended Depth of Focus
by Kwang Eon Han and Ji Eun Lee
J. Clin. Med. 2023, 12(23), 7368; https://doi.org/10.3390/jcm12237368 - 28 Nov 2023
Cited by 4 | Viewed by 2462
Abstract
(1) Background: Cataract surgery has evolved significantly with the development of multifocal and extended depth-of-focus intraocular lenses (IOLs), driven by increasing patient desire for spectacle independence. (2) Methods: This retrospective, single-center study conducted on 86 eyes from 59 patients aged 40–80 years compared [...] Read more.
(1) Background: Cataract surgery has evolved significantly with the development of multifocal and extended depth-of-focus intraocular lenses (IOLs), driven by increasing patient desire for spectacle independence. (2) Methods: This retrospective, single-center study conducted on 86 eyes from 59 patients aged 40–80 years compared the performance and patient satisfaction of Symfony® and Synergy® (Johnson & Johnson Vision) IOLs during a follow-up of 1 year postsurgery. Uncorrected and corrected distance, intermediate, and near visual acuities were assessed (UDVA, CDVA, UIVA, CIVA, UNVA, and CNVA, respectively). (3) Results: Although both IOLs demonstrated a commendable distance VA, Synergy® outperformed in near VA (UNVA, p = 0.040; CNVA, p = 0.014), and Symfony® slightly excelled in intermediate VA (UIVA, p = 0.014; CIVA, p = 0.040). The defocus curve of Synergy® maintained a higher VA even at −4 D with a smoother curve and a broad landing zone. Although the optical quality assessments were similar, Symfony® had a nonsignificant edge. Patients indicated higher satisfaction and reduced reliance on spectacles with Synergy® despite more frequent reports of glare and halos. (4) Conclusions: These findings highlight the importance of personalized IOL selection in cataract surgery, which must be customized to apply the distinctive advantages of each IOL to address the unique visual requirements and lifestyle of patients. Full article
(This article belongs to the Special Issue New Advances in Cataract and Refractive Surgery)
Show Figures

Figure 1

17 pages, 3292 KB  
Article
Assessing Visual Outcomes: A Comparative Study of US-FDA Premarket Approval Data for Multifocal and EDOF Lens Implants in Cataract Surgery
by Majid Moshirfar, Isabella M. Stoakes, Joshua S. Theis, Kaiden B. Porter, Jordan M. Santos, Tanisha Martheswaran, Carter J. Payne and Phillip C. Hoopes
J. Clin. Med. 2023, 12(13), 4365; https://doi.org/10.3390/jcm12134365 - 28 Jun 2023
Cited by 10 | Viewed by 3626
Abstract
This study compares the efficacy, safety, and patient-reported outcomes of three intraocular implants (IOL): Tecnis Synergy IOL, AcrySof IQ PanOptix Trifocal, and Tecnis Symfony EDOF IOL. Participants achieving 20/20 or better uncorrected binocular visual acuity were as follows: Synergy—67% distance, 64% intermediate, and [...] Read more.
This study compares the efficacy, safety, and patient-reported outcomes of three intraocular implants (IOL): Tecnis Synergy IOL, AcrySof IQ PanOptix Trifocal, and Tecnis Symfony EDOF IOL. Participants achieving 20/20 or better uncorrected binocular visual acuity were as follows: Synergy—67% distance, 64% intermediate, and 47% near; PanOptix—73% distance, 73% intermediate, and 50% near; and Symfony—63% distance, 75% intermediate, and 22% near. Symfony demonstrated superior intermediate visual acuity compared to Synergy (p = 0.0182) for those achieving 20/25 or better. Both Synergy and PanOptix showed superiority over Symfony for near visual acuity (p < 0.0001). Halos were statistically more common in Synergy participants compared to PanOptix (p = 0.0013) and Symfony (p < 0.0001). Each trial lens outperformed its monofocal IOL in terms of independence from glasses or contacts, with Synergy and PanOptix showing statistical significance over Symfony. Comparing contrast sensitivities and defocus curves was challenging due to data variance and as such, standardization of United States Food and Drug Administration (US-FDA) data reporting is key for better comparison of outcomes among different IOL platforms. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

16 pages, 2565 KB  
Article
Comparative Visual Outcome Analysis of a Diffractive Multifocal Intraocular Lens and a New Diffractive Multifocal Lens with Extended Depth of Focus
by Majid Moshirfar, Seth R. Stapley, Wyatt M. Corbin, Nour Bundogji, Matthew Conley, Ines M. Darquea, Yasmyne C. Ronquillo and Phillip C. Hoopes
J. Clin. Med. 2022, 11(24), 7374; https://doi.org/10.3390/jcm11247374 - 12 Dec 2022
Cited by 23 | Viewed by 4449
Abstract
This study compares the visual and refractive performance of the TECNIS Synergy (DFR00V-DFW150-225-300-375) multifocal intraocular lens (IOL) and the AcrySof IQ PanOptix (TFAT00-30-40-50-60) multifocal IOL. Patients who underwent phacoemulsification and cataract extraction and received either a multifocal Synergy or PanOptix IOL were included. [...] Read more.
This study compares the visual and refractive performance of the TECNIS Synergy (DFR00V-DFW150-225-300-375) multifocal intraocular lens (IOL) and the AcrySof IQ PanOptix (TFAT00-30-40-50-60) multifocal IOL. Patients who underwent phacoemulsification and cataract extraction and received either a multifocal Synergy or PanOptix IOL were included. Monocular uncorrected distance (UDVA), intermediate (UIVA), near (UNVA), and corrected distance (CDVA) visual acuities were assessed at three and six months postoperatively. Secondary outcome measures of photic phenomena were also assessed. A total of 140 patients (224 eyes) were included in this study, with 69 patients (105 eyes) in the Synergy group and 71 patients (119 eyes) in the PanOptix group. There were no statistically significant differences in UIVA or CDVA measurements across all time points. When assessing UDVA, at three months postoperatively, there were more eyes in the PanOptix group with vision better than 20/40 (p = 0.04). At three and six months postoperatively, the average UNVA was superior in the Synergy group (p = 0.01, 0.002). While the Synergy group reported more night vision disturbances at one and three months (p = 0.01, 0.03), the PanOptix group had more night vision disturbances at six months (p = 0.02). Although not statistically significant, the AcrySof IQ PanOptix multifocal IOL demonstrated better UDVA and UIVA sooner postoperatively than the TECNIS Synergy multifocal IOL. The Synergy IOL provided statistically better UNVA compared to the PanOptix IOL at three and six months postoperatively. Synergy patients reported more early photic phenomena than PanOptix patients, which later diminished. Full article
(This article belongs to the Special Issue Cataract Surgery and Postoperative Care – Part II)
Show Figures

Figure 1

9 pages, 4320 KB  
Article
Visualization of Ray Propagation through Extended Depth-of-Focus Intraocular Lenses
by Isabella D. Baur, Gerd U. Auffarth, Weijia Yan, Grzegorz Łabuz and Ramin Khoramnia
Diagnostics 2022, 12(11), 2667; https://doi.org/10.3390/diagnostics12112667 - 2 Nov 2022
Cited by 12 | Viewed by 4436
Abstract
Extended depth-of-focus (EDoF) presbyopia-correcting intraocular lens (IOL) models differ in their optical design and performance. In the laboratory, we compared the ray propagation and light intensity profiles of four IOLs: the non-diffractive AcrySof IQ Vivity (Alcon Inc., Fort Worth, TX, USA) and two [...] Read more.
Extended depth-of-focus (EDoF) presbyopia-correcting intraocular lens (IOL) models differ in their optical design and performance. In the laboratory, we compared the ray propagation and light intensity profiles of four IOLs: the non-diffractive AcrySof IQ Vivity (Alcon Inc., Fort Worth, TX, USA) and two diffractive models, Symfony ZXR00 (Johnson & Johnson Vision, Jacksonville, FL, USA) and AT Lara 829 MP (Carl Zeiss Meditec, Berlin, Germany). A fourth lens, the monofocal AcrySof IQ SN60WF (Alcon Inc.) acted as the control. We projected a 520 nm laser light through each submerged lens in a bath of fluorescein solution. A camera mounted on a microscope captured the light that emerged from the IOL. We recorded the IOLs’ point spread function (PSF) to determine the presence of unwanted visual effects. The ray propagation visualization and light intensity profile of the monofocal control showed one distinct focus, while the AcrySof IQ Vivity demonstrated an extended focus area. We observed two distinct foci with each diffractive IOL. We found a lower level of light spread beyond the PSF center for the AcrySof IQ Vivity compared to the diffractive IOLs. In conclusion, we could confirm the extended range of focus for all the EDoF IOL models. However, the non-diffractive AcrySof IQ Vivity appears to have a smoother transition from a far to an intermediate range. We discuss whether, in clinical use, the higher level of spurious light we found in the diffractive designs may translate into increased dysphotopsia. Full article
(This article belongs to the Special Issue Refining Diagnosis in Ophthalmology through Laboratory Research)
Show Figures

Figure 1

11 pages, 1842 KB  
Article
Clinical Outcomes after Bilateral Implantation of Trifocal Diffractive Intraocular Lenses and Extended Depth of Focus Intraocular Lenses
by Kyoung Yoon Shin, Dong Hui Lim and Tae-Young Chung
J. Clin. Med. 2022, 11(19), 5729; https://doi.org/10.3390/jcm11195729 - 27 Sep 2022
Cited by 4 | Viewed by 3330
Abstract
The purpose of this retrospective study is to investigate clinical outcomes of bilateral implantation of diffractive trifocal intraocular lenses (IOLs) and extended depth of focus IOLs in Koreans. The clinical outcomes of cataract surgery with bilateral implantation of PanOptix, FineVision, Symfony, and MiniWell [...] Read more.
The purpose of this retrospective study is to investigate clinical outcomes of bilateral implantation of diffractive trifocal intraocular lenses (IOLs) and extended depth of focus IOLs in Koreans. The clinical outcomes of cataract surgery with bilateral implantation of PanOptix, FineVision, Symfony, and MiniWell were evaluated. Uncorrected distant, intermediate (80 cm, 60 cm), near (40 cm) visual acuity, defocus curve, manifest refraction, contrast sensitivity, and higher-order aberrations, quality of vision, spectacle independence, and subjective satisfaction at postoperative 3 months were assessed. A total of 136 eyes in 68 patients were included in the analyses. PanOptix and FineVision performed better visual acuity compared to Symfony and MiniWell at 40 cm distance. Defocus curve showed broad range of vision in PanOptix and FineVision with visual acuity of more than 0.1 logarithm of the minimum angle of resolution at −2.5 diopter (D) of defocus power, while Symfony and MiniWell presented excellent intermediate vision without a dip at defocus power of −0.5 D to −1.0 D. Glare, halo, and starburst were significantly less in MiniWell compared to others. In conclusion, all four IOLs presented satisfactory clinical outcomes. PanOptix and FineVision provided good near and intermediate vision, while Symfony and MiniWell provided good intermediate vision. MiniWell induced little dysphotopsia. Full article
(This article belongs to the Special Issue Cataract Surgery and Postoperative Care – Part II)
Show Figures

Figure 1

11 pages, 998 KB  
Article
Far and Near Contrast Sensitivity and Quality of Vision with Six Presbyopia Correcting Intraocular Lenses
by Miguel Á. Gil, Consuelo Varón, Genis Cardona and José A. Buil
J. Clin. Med. 2022, 11(14), 4150; https://doi.org/10.3390/jcm11144150 - 17 Jul 2022
Cited by 13 | Viewed by 3328
Abstract
The objective of this prospective, randomized, double-masked study was to compare the contrast sensitivity and quality of vision of patients bilaterally implanted with the following six different presbyopia correcting intraocular lenses (IOLs): SV25T0 (n = 19), ATLISA 809M (n = 18), [...] Read more.
The objective of this prospective, randomized, double-masked study was to compare the contrast sensitivity and quality of vision of patients bilaterally implanted with the following six different presbyopia correcting intraocular lenses (IOLs): SV25T0 (n = 19), ATLISA 809M (n = 18), ATLISA TRI 839MP (n = 19), ZKB00 (n = 20), ZLB00 (n = 20) and Symfony ZXR00 (n = 20). For comparison purposes, 36 patients were implanted with a monofocal lens (ZA9003). Contrast sensitivity was assessed binocularly at distance under photopic, mesopic and mesopic plus glare conditions, and at near under photopic conditions. Quality of vision was explored in terms of photic phenomena and spectacle independence. Overall, the monofocal lens offered better contrast sensitivity, under all illumination conditions, and less occurrence and intensity of photic phenomena. Amongst the multifocal IOL (MIOL) designs, the extended depth of focus Symfony ZXR00 provided better contrast sensitivity than the other MIOLs, particularly at intermediate and high spatial frequencies. Up to 40% and 50% of patients implanted with MIOLs reported glare and halos, respectively. The SV25T0 resulted in less occurrence and intensity of halos. The evaluation of photic phenomena and contrast sensitivity under different illumination conditions may reflect real-life, visually challenging situations, and thus provide insightful information to assist ophthalmic surgeons when selecting the best intraocular lens for their patients. Full article
(This article belongs to the Special Issue Cataract Surgery and Postoperative Care – Part II)
Show Figures

Figure 1

Back to TopTop