Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (162)

Search Parameters:
Keywords = cobalt chromium alloy

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 12766 KB  
Article
Shaping the Structure and Properties of Stellite 6 Alloy by Addition of Ti and W via Laser Cladding
by Jacek Górka, Tomasz Poloczek, Damian Janicki and Aleksandra Lont
Materials 2025, 18(17), 3968; https://doi.org/10.3390/ma18173968 (registering DOI) - 25 Aug 2025
Abstract
Cobalt-based alloys such as Stellite 6 are widely applied in demanding conditions because of their good resistance to wear, erosion, and corrosion, but further improvements in erosion resistance are still required. This work analyzes the effect of adding titanium and tungsten on the [...] Read more.
Cobalt-based alloys such as Stellite 6 are widely applied in demanding conditions because of their good resistance to wear, erosion, and corrosion, but further improvements in erosion resistance are still required. This work analyzes the effect of adding titanium and tungsten on the structure and properties of Stellite 6 coatings produced by laser cladding, aiming to enhance their erosion resistance. Penetrant tests confirmed that the additions did not reduce coating quality, and macroscopic observations showed that appropriate process parameters allowed for defect-free coatings with strong bonding to the substrate. Microstructural studies carried out by SEM/EDS (Scanning Electron Microscopy/ Energy Dispersive Spectroscopy) and XRD (X-ray Diffraction) revealed that the reference Stellite 6 coating consisted of a cobalt-based austenitic matrix with interdendritic chromium carbides, while Ti and W additions led to the in situ formation of primary and eutectic (Ti,W)C carbides. Transmission electron microscopy showed a gradient in tungsten concentration inside the primary carbides, with progressive tungsten dissolution into the TiC lattice. Although different powder compositions had only a moderate effect on hardness, erosion tests demonstrated that the coatings with Ti and W exhibited clearly improved resistance. In particular, the in situ carbides enhanced erosion resistance at 30° impingement angles, while also maintaining high resistance under 90° impact. These findings confirm that modifying Stellite 6 with Ti and W during laser cladding is an effective way to improve its durability in erosive conditions. Full article
(This article belongs to the Special Issue Fusion Bonding/Welding of Metal and Non-Metallic Materials)
Show Figures

Graphical abstract

14 pages, 2251 KB  
Review
Porcelain Fused to Titanium—Advantages and Challenges
by Zlatina Tomova, Desislav Tomov, Angelina Vlahova, Gergana Kirova and Yordanka Uzunova
Dent. J. 2025, 13(9), 382; https://doi.org/10.3390/dj13090382 - 24 Aug 2025
Abstract
Although dental implants appear to be an alternative for treatment of tooth loss, fixed prosthetic restorations are an irreplaceable part of oral rehabilitation. Regarding the EU directives concerning cobalt health risks, titanium alloys may be an alternative to cobalt–chromium and nickel–chromium for metal–ceramic [...] Read more.
Although dental implants appear to be an alternative for treatment of tooth loss, fixed prosthetic restorations are an irreplaceable part of oral rehabilitation. Regarding the EU directives concerning cobalt health risks, titanium alloys may be an alternative to cobalt–chromium and nickel–chromium for metal–ceramic dental restorations. The presented review briefly describes the specific properties of titanium, and the challenges met during production and use of titanium–ceramic fixed prosthetic restorations. Full article
(This article belongs to the Special Issue Dental Materials Design and Application)
Show Figures

Figure 1

20 pages, 691 KB  
Review
Alloy Selection and Manufacturing Technologies for Total Ankle Arthroplasty: A Narrative Review
by Kishen Mitra, Arun K. Movva, Michael O. Sohn, Joshua M. Tennyson, Grayson M. Talaski, Samuel B. Adams and Albert T. Anastasio
Materials 2025, 18(16), 3770; https://doi.org/10.3390/ma18163770 - 11 Aug 2025
Viewed by 365
Abstract
Total ankle arthroplasty (TAA) has evolved significantly through advances in alloy selection and manufacturing technologies. This narrative review examines the metallurgical foundations of contemporary TAA implants, analyzing primary alloy systems and their mechanical properties. Cobalt-chromium alloys provide superior mechanical strength and durability but [...] Read more.
Total ankle arthroplasty (TAA) has evolved significantly through advances in alloy selection and manufacturing technologies. This narrative review examines the metallurgical foundations of contemporary TAA implants, analyzing primary alloy systems and their mechanical properties. Cobalt-chromium alloys provide superior mechanical strength and durability but present metal ion release concerns, while titanium alloys (Ti6Al4V) optimize biocompatibility with elastic modulus values (101–113 GPa) closer to bone, despite tribological limitations. Novel β-titanium formulations (Ti-35Nb-7Zr-5Ta, Ti10Mo6Zr4Sn3Nb) eliminate toxic aluminum and vanadium components while achieving lower elastic modulus values (50–85 GPa) that better match cortical bone properties. Manufacturing has transitioned from traditional methods (investment casting, forging, CNC machining) toward additive manufacturing technologies. Selective laser melting and electron beam melting enable patient-specific geometries, controlled porosity, and optimized microstructures, though challenges remain with residual stresses, surface finish requirements, and post-processing needs. Emerging biodegradable materials, composite structures, and hybrid implant designs represent promising future directions for addressing current material limitations. This review provides evidence-based insights for alloy selection and manufacturing approaches, emphasizing the critical role of materials engineering in TAA implant performance and clinical outcomes. Full article
(This article belongs to the Special Issue Microstructure and Mechanical Properties of Alloys (2nd Edition))
Show Figures

Figure 1

20 pages, 7843 KB  
Article
Effect of Ageing on a Novel Cobalt-Free Precipitation-Hardenable Martensitic Alloy Produced by SLM: Mechanical, Tribological and Corrosion Behaviour
by Inés Pérez-Gonzalo, Florentino Alvarez-Antolin, Alejandro González-Pociño and Luis Borja Peral-Martinez
J. Manuf. Mater. Process. 2025, 9(8), 261; https://doi.org/10.3390/jmmp9080261 - 4 Aug 2025
Viewed by 485
Abstract
This study investigates the mechanical, tribological, and electrochemical behaviour of a novel precipitation-hardenable martensitic alloy produced by selective laser melting (SLM). The alloy was specifically engineered with an optimised composition, free from cobalt and molybdenum, and featuring reduced nickel content (7 wt.%) and [...] Read more.
This study investigates the mechanical, tribological, and electrochemical behaviour of a novel precipitation-hardenable martensitic alloy produced by selective laser melting (SLM). The alloy was specifically engineered with an optimised composition, free from cobalt and molybdenum, and featuring reduced nickel content (7 wt.%) and 8 wt.% chromium. It has been developed as a cost-effective and sustainable alternative to conventional maraging steels, while maintaining high mechanical strength and a refined microstructure tailored to the steep thermal gradients inherent to the SLM process. Several ageing heat treatments were assessed to evaluate their influence on microstructure, hardness, tensile strength, retained austenite content, dislocation density, as well as wear behaviour (pin-on-disc test) and corrosion resistance (polarisation curves in 3.5%NaCl). The results indicate that ageing at 540 °C for 2 h offers an optimal combination of hardness (550–560 HV), tensile strength (~1700 MPa), microstructural stability, and wear resistance, with a 90% improvement compared to the as-built condition. In contrast, ageing at 600 °C for 1 h enhances ductility and corrosion resistance (Rp = 462.2 kΩ; Ecorr = –111.8 mV), at the expense of a higher fraction of reverted austenite (~34%) and reduced hardness (450 HV). This study demonstrates that the mechanical, surface, and electrochemical performance of this novel SLM-produced alloy can be effectively tailored through controlled thermal treatments, offering promising opportunities for demanding applications requiring a customised balance of strength, durability, and corrosion behaviour. Full article
Show Figures

Graphical abstract

17 pages, 2870 KB  
Article
Influence of Magnetorheological Finishing on Surface Topography and Functional Performance of Shoulder Joint Cap Surface
by Manpreet Singh, Gagandeep Singh, Riyad Abu-Malouh, Sumika Chauhan and Govind Vashishtha
Materials 2025, 18(14), 3397; https://doi.org/10.3390/ma18143397 - 20 Jul 2025
Viewed by 429
Abstract
The surface quality of biomedical implants, such as shoulder joint caps, plays a critical role in their performance, longevity, and biocompatibility. Most biomedical shoulder joints fail to reach their optimal functionality when finished through conventional techniques like grinding and lapping due to their [...] Read more.
The surface quality of biomedical implants, such as shoulder joint caps, plays a critical role in their performance, longevity, and biocompatibility. Most biomedical shoulder joints fail to reach their optimal functionality when finished through conventional techniques like grinding and lapping due to their inability to achieve nanometer-grade smoothness, which results in greater wear and friction along with potential failure. The advanced magnetorheological finishing (MRF) approach provides enhanced surface quality through specific dimensional control material removal. This research evaluates how MRF treatment affects the surface roughness performance and microhardness properties and wear resistance behavior of cobalt–chromium alloy shoulder joint caps which have biocompatible qualities. The study implements a magnetorheological finishing system built with an electromagnetic tool to achieve the surface roughness improvements from 0.35 µm to 0.03 µm. The microhardness measurements show that MRF applications lead to a rise from HV 510 to HV 560 which boosts the wear protection of samples. After MRF finishing, the coefficient of friction demonstrates a decrease from 0.12 to 0.06 which proves improved tribological properties of these implants. The results show that MRF technology delivers superior benefits for biomedical use as it extends implant life span and decreases medical complications leading to better patient health outcomes. The purposeful evaluation of finishing techniques and their effects on implant functionality demonstrates MRF is an advanced technology for upcoming orthopedic implants while yielding high precision and enhanced durability and functional output. Full article
Show Figures

Figure 1

20 pages, 24228 KB  
Article
Surface Treatments on Cobalt–Chromium Alloys for Layering Ceramic Paint Coatings in Dental Prosthetics
by Willi-Andrei Uriciuc, Maria Suciu, Lucian Barbu-Tudoran, Adrian-Ioan Botean, Horea Florin Chicinaș, Miruna-Andreea Anghel, Cătălin Ovidiu Popa and Aranka Ilea
Coatings 2025, 15(7), 833; https://doi.org/10.3390/coatings15070833 - 17 Jul 2025
Viewed by 866
Abstract
Ceramic dental prosthetics with internal metal structures are made from a cobalt–chromium alloy that is coated with ceramic. This study aims to validate surface treatments for the metal that enhance the adhesion of the ceramic coating under masticatory forces. Surface conditioning is performed [...] Read more.
Ceramic dental prosthetics with internal metal structures are made from a cobalt–chromium alloy that is coated with ceramic. This study aims to validate surface treatments for the metal that enhance the adhesion of the ceramic coating under masticatory forces. Surface conditioning is performed using mechanical methods, like sandblasting (SB), and thermal methods, such as oxidation (O). The ceramic coating is applied to the metal component following the conditioning process, which can be conducted using either a single method or a combination of methods. Each conditioned sample undergoes characterization through various techniques, including drop shape analysis (DSA), scanning electron microscopy (SEM), X-ray diffraction (EDX), and atomic force microscopy (AFM). After the ceramic coating is applied and subjected to thermal sintering, the metal–ceramic samples are mechanically tested to assess the adhesion of the ceramic layer. The research findings, illustrated by scanning electron microscopy (SEM) images of the metal structures’ surfaces, indicate that alloy powder particles ranging from 10 to 50 µm were either adhered to the surfaces or present as discrete dots. Particles that exceed the initial design specifications of the structure can be smoothed out using sandblasting or mechanical finishing techniques. The energy-dispersive spectroscopy (EDS) results show that, after sandblasting, fragments of aluminum oxide remain trapped on the surface of the metal structures. These remnants are considered impurities, which can negatively impact the adhesion of the ceramic to the metal substrate. The analysis focuses on the exfoliation of the ceramic material from the deformed metal surfaces. The results emphasize the significant role of the sandblasting method and the micro-topography it creates, as well as the importance of the oxidation temperature in the treatment process. Drawing on 25 years of experience in dental prosthetics and the findings from this study, this publication aims to serve as a guide for applying the ceramic bonding layer to metal surfaces and for conditioning methods. These practices are essential for enhancing the adhesion of ceramic materials to metal substrates. Full article
(This article belongs to the Special Issue Corrosion and Corrosion Prevention in Extreme Environments)
Show Figures

Figure 1

14 pages, 6398 KB  
Article
Corrosion Behavior of Additively Manufactured GRX-810 Alloy in 3.5 wt.% NaCl
by Peter Omoniyi, Samuel Alfred, Kenneth Looby, Olu Bamiduro, Mehdi Amiri and Gbadebo Owolabi
Materials 2025, 18(14), 3252; https://doi.org/10.3390/ma18143252 - 10 Jul 2025
Viewed by 411
Abstract
This study examines the corrosion characteristics of GRX-810, a NiCoCr-based high entropy alloy, in a simulated marine environment represented by 3.5 wt.% NaCl solution. The research employs electrochemical and surface analysis techniques to evaluate the corrosion performance and protective mechanisms of this alloy. [...] Read more.
This study examines the corrosion characteristics of GRX-810, a NiCoCr-based high entropy alloy, in a simulated marine environment represented by 3.5 wt.% NaCl solution. The research employs electrochemical and surface analysis techniques to evaluate the corrosion performance and protective mechanisms of this alloy. Electrochemical characterization was performed using potentiodynamic polarization to determine critical corrosion parameters, including corrosion potential and current density, along with electrochemical impedance spectroscopy to assess the stability and protective qualities of the oxide film. Surface analytical techniques provided detailed microstructural and compositional insights, with scanning electron microscopy revealing the morphology of corrosion products, energy-dispersive X-ray spectroscopy identifying elemental distribution in the passive layer, and X-ray diffraction confirming the chemical composition and crystalline structure of surface oxide. The results demonstrated distinct corrosion resistance behavior between the different processing conditions of the alloy. The laser powder bed fused (LPBF) specimens in the as-built condition exhibited superior corrosion resistance compared to their hot isostatically pressed (HIPed) counterparts, as evidenced by higher corrosion potentials and lower current densities. Microscopic examination revealed the formation of a dense, continuous layer of corrosion products on the alloy surface, indicating effective barrier protection against chloride ion penetration. A compositional analysis of all samples identified oxide film enriched with chromium, nickel, cobalt, aluminum, titanium, and silicon. XRD characterization confirmed the presence of chromium oxide (Cr2O3) as the primary protective phase, with additional oxides contributing to the stability of the film. This oxide mixture demonstrated the alloy’s ability to maintain passivity and effective repassivation following film breakdown. Full article
(This article belongs to the Special Issue Study on Electrochemical Behavior and Corrosion of Materials)
Show Figures

Figure 1

12 pages, 2705 KB  
Article
Electrochemical Behavior of Cobalt–Chromium Alloy Exposed to Effervescent Denture Cleansers
by Glenda Lara Lopes Vasconcelos, Carolina Alves Freiria de Oliveira, Ana Paula Macedo, Viviane de Cássia Oliveira, Patrícia Almeida Curylofo, Carlos Alberto Della Rovere, Rodrigo Galo, Bruna S. H. Tonin and Valéria Oliveira Pagnano
Corros. Mater. Degrad. 2025, 6(2), 23; https://doi.org/10.3390/cmd6020023 - 12 Jun 2025
Viewed by 566
Abstract
This study demonstrates that effervescent denture cleansers can influence the electrochemical behavior of cobalt–chromium (Co-Cr) alloys, with a particular focus on their corrosion resistance. The findings underscore the importance for dental professionals of selecting cleansers compatible with Co-Cr prostheses to minimize material degradation [...] Read more.
This study demonstrates that effervescent denture cleansers can influence the electrochemical behavior of cobalt–chromium (Co-Cr) alloys, with a particular focus on their corrosion resistance. The findings underscore the importance for dental professionals of selecting cleansers compatible with Co-Cr prostheses to minimize material degradation and enhance clinical durability. Corrosion resistance was evaluated using open-circuit potential (OCP), corrosion current density (icorr), and passivation current density (ipass). Surface morphology and elemental composition were analyzed through scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Forty specimens (n = 5 per group) were individually immersed in one of ten test solutions: distilled water (DW), artificial saliva (AS), and eight commercial denture cleansers—Polident 3 minutes™ (P3M), Steradent™ (St), Polident for Partials™ (PP), Efferdent™ (Ef), Corega Tabs™ (CT), NitrAdine™ (Ni), Fixodent™ (Fi), and Kukident™ (Ku). Each specimen was exposed a single solution to avoid cross-contamination. Results showed St, Ef, and Ku had higher OCP values than DW and Ni (p < 0.05), indicating better corrosion resistance. AS exhibited lower OCP values compared to St (p = 0.034), Ku (p = 0.023), and P3M (p = 0.050). DW had higher icorr than PP (p = 0.030), CT (p = 0.005), and P3M (p = 0.003). For ipass, DW had lower values than Ef (p = 0.025) and Ku (p = 0.016). SEM and EDS revealed no significant surface alterations. Understanding the underlying corrosion mechanisms in different solutions provides valuable insights into optimizing material performance and ensuring durability in clinical applications. The corrosion resistance of Co-Cr depends on the stability of the passive oxide layer, which can be degraded by chloride ions, reinforced by sulfate ions, and influenced by active ingredients in denture cleansers. Overall, the Co-Cr alloy demonstrated acceptable corrosion resistance, underscoring the importance of selecting suitable cleansers for prosthesis longevity. Full article
(This article belongs to the Special Issue Advances in Material Surface Corrosion and Protection)
Show Figures

Graphical abstract

23 pages, 5628 KB  
Article
Optimization of Bond Strength Between Heat-Polymerized PMMA and Contemporary CAD/CAM Framework Materials: A Comparative In Vitro Study
by Başak Topdağı
Polymers 2025, 17(11), 1488; https://doi.org/10.3390/polym17111488 - 27 May 2025
Cited by 1 | Viewed by 596
Abstract
This study aimed to comparatively evaluate the effects of various surface treatment protocols on the shear bond strength (SBS) between heat-polymerized polymethyl methacrylate (PMMA) and different CAD/CAM framework materials, including cobalt–chromium (Co–Cr) alloys, ceramic particle-reinforced polyetheretherketone (PEEK), and glass fiber-reinforced composite resin (FRC). [...] Read more.
This study aimed to comparatively evaluate the effects of various surface treatment protocols on the shear bond strength (SBS) between heat-polymerized polymethyl methacrylate (PMMA) and different CAD/CAM framework materials, including cobalt–chromium (Co–Cr) alloys, ceramic particle-reinforced polyetheretherketone (PEEK), and glass fiber-reinforced composite resin (FRC). A total of 135 disc-shaped specimens were prepared from Co–Cr, PEEK, and FRC materials. Surface treatments specific to each material, including airborne-particle abrasion, sulfuric acid etching, laser irradiation, plasma activation, and primer application, were applied. PMMA cylinders were polymerized onto the treated surfaces, and all specimens were subjected to 30,000 thermal cycles. SBS values were measured using a universal testing machine, and the failure modes were classified. The normality of data distribution was assessed using the Kolmogorov–Smirnov test, and the homogeneity of variances was evaluated using Levene’s test. Group comparisons were performed using the Kruskal–Wallis test, and Dunn’s post hoc test with Bonferroni correction was applied in cases where significant differences were detected (α = 0.05). The highest SBS values (~27–28 MPa) were obtained in the Co–Cr group and in the PEEK groups treated with sulfuric acid and primer. In contrast, the PEEK group with additional laser treatment exhibited a lower SBS value. The untreated PEEK group showed significantly lower SBS (~3.9 MPa) compared to all other groups. The Trinia groups demonstrated intermediate SBS values (16.5–17.4 MPa), which exceeded the clinically acceptable threshold of 10 MPa. SEM observations revealed material- and protocol-specific surface responses; plasma-treated specimens maintained topographic integrity, whereas laser-induced surfaces showed localized degradation, particularly following dual-step protocols. Fracture mode analysis indicated that higher SBS values were associated with cohesive or mixed failures. SEM observations suggested that plasma treatment preserved surface morphology more effectively than laser treatment. This study highlights the importance of selecting material-specific surface treatments to optimize bonding between CAD/CAM frameworks and PMMA. Sulfuric acid and primer provided strong adhesion for PEEK, while the addition of laser or plasma offered no further benefit, making such steps potentially unnecessary. Trinia frameworks also showed acceptable performance with conventional treatments. These findings reinforce that simplified conditioning protocols may be clinically sufficient, and indicate that FRC materials like Trinia should be more fully considered for their broader clinical potential in modern CAD/CAM-based prosthetic planning. Full article
(This article belongs to the Special Issue Advances in Polymer Composites II)
Show Figures

Figure 1

24 pages, 7910 KB  
Article
Optimization of Magnetic Finishing Process and Surface Quality Research for Inner Wall of MP35N Cobalt–Chromium Alloy Vascular Stent Tubing Based on Plasma-Fused Al2O3 Magnetic Abrasives
by Yusheng Zhang, Yugang Zhao, Qilong Fan, Shimin Yang, Shuo Meng, Yu Tang, Guiguan Zhang and Haiyun Zhang
Micromachines 2025, 16(5), 591; https://doi.org/10.3390/mi16050591 - 18 May 2025
Viewed by 721
Abstract
To solve the manufacturing problem of the efficient removal of multi-scale surface defects (wrinkles, cracks, scratches, etc.) on the inner wall of MP35N cobalt–chromium alloy vascular stents, this study proposes a collaborative optimization strategy of magnetic abrasive polishing (MAF) based on a new [...] Read more.
To solve the manufacturing problem of the efficient removal of multi-scale surface defects (wrinkles, cracks, scratches, etc.) on the inner wall of MP35N cobalt–chromium alloy vascular stents, this study proposes a collaborative optimization strategy of magnetic abrasive polishing (MAF) based on a new type of magnetic abrasive. In response to the unique requirements for the inner wall processing of high aspect ratio microtubes, metal-based Al2O3 magnetic abrasives with superior performance were prepared by the plasma melt powder spraying method. A special MAF system for the inner wall of the bracket was designed and constructed. The four-factor and three-level Box–Behnken response surface method was adopted to analyze the influences and interactions of tube rotational speed, magnetic pole feed rate, abrasive filling amount, and processing clearance on surface roughness (Ra). The significance order of each parameter for Ra is determined as follows: processing clearance > tube rotational speed > abrasive filling amount > magnetic pole feed rate. Using the established model and multiple regression equations, the optimal parameters were determined as follows: a tube rotational speed of 600 r/min, a magnetic pole feed rate of 150 mm/min, an abrasive filling amount of 0.50 g, and a processing clearance of 0.50 mm. The optimized model predicted an Ra value of 0.104 μm, while the average Ra value verified experimentally was 0.107 μm, with the minimum error being 2.9%. Compared with the initial Ra of 0.486 μm, directly measured by the ultra-depth-of-field 3D microscope of model DSX1000, the surface roughness was reduced by 77.98%. MAF effectively eliminates the surface defects and deteriorated layers on the inner wall of MP35N tubes, significantly improving the surface quality, which is of great significance for the subsequent preparation of high-quality vascular stents and their clinical applications. Full article
(This article belongs to the Special Issue Advanced Manufacturing Technology and Systems, 3rd Edition)
Show Figures

Figure 1

11 pages, 429 KB  
Systematic Review
Measuring the Marginal Gap of Pre-Cemented All-Metal Single Crowns: A Systematic Review of In Vitro Studies
by James Dudley and Taseef Hasan Farook
Dent. J. 2025, 13(5), 204; https://doi.org/10.3390/dj13050204 - 2 May 2025
Viewed by 1272
Abstract
Background: Different methods have been used to fabricate and measure marginal gap in all-metal crowns, yet a systematic review on this topic has not been conducted. Objective: To review the existing literature regarding the measurement methods employed for the in vitro marginal gap [...] Read more.
Background: Different methods have been used to fabricate and measure marginal gap in all-metal crowns, yet a systematic review on this topic has not been conducted. Objective: To review the existing literature regarding the measurement methods employed for the in vitro marginal gap measurement of pre-cemented all-metal single crowns and examine the influence of crown fabrication method on the marginal gap. Materials and Methods: A systematic search was performed from December 2024 backwards across EBSCO Host, Scopus, PubMed, and Web of Science databases following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and predefined eligibility criteria. The quality of included articles was evaluated using the Joanna Briggs Critical Appraisal Checklist. Results: Ten studies, involving 180 crowns, assessed marginal gaps using computerised superimposition (102 µm), scanning electron microscopy (89 µm), profilometry (100 µm), photogrammetry (59 µm), impression replica techniques (124 µm), and direct view microscopy (35 µm). Marginal gaps varied across crowns constructed with cobalt–chromium (97 µm), titanium (56 µm), noble metals (127 µm), and base metal alloys (35 µm). No significant differences (t = 1.06, p = 0.315) were observed between CAD/CAM (103.21 ± 58.56 µm) and lost wax casting method (71.59 ± 43.94 µm) of crown fabrication when analysed using an independent t-test. Conclusions: Cobalt–chromium was the most used material for AMCs, while titanium alloys produced the lowest mean marginal gap per crown. No significant differences in reported marginal gaps were observed between crowns fabricated using lost wax casting and CAD/CAM techniques. However, the limited number of studies, variation in measurement methods, and inconsistency in methodological rigour restricted the generalisability of the findings. Full article
(This article belongs to the Section Dental Materials)
Show Figures

Figure 1

25 pages, 14859 KB  
Article
The Effect of Drag Finishing on Additively Manufactured Customized Dental Crowns
by Cosmin Cosma, Martin Melichar, Stelian Libu, Alexandru Popan, Glad Contiu, Cristina Teusan, Petru Berce and Nicolae Balc
Metals 2025, 15(5), 471; https://doi.org/10.3390/met15050471 - 22 Apr 2025
Viewed by 823
Abstract
Cobalt–chromium (CoCr) alloys are frequently used to produce customized dental applications such as crowns, bridges, or prostheses. These medical products have anatomical forms, and can be effectively manufactured using the laser-based powder bed fusion (PBF-LB/M) technique. A major disadvantage of this approach is [...] Read more.
Cobalt–chromium (CoCr) alloys are frequently used to produce customized dental applications such as crowns, bridges, or prostheses. These medical products have anatomical forms, and can be effectively manufactured using the laser-based powder bed fusion (PBF-LB/M) technique. A major disadvantage of this approach is the extended time required to refine the resultant surface. The purpose of this research is to reduce the surface roughness of PBF-LB/M/CoCr dental crowns by adopting drag finishing (DF) technology. To evaluate the impact of this automatic post-processing, surface roughness measurements and geometrical investigations were undertaken. The microstructure was characterized using scanning electron microscopy (SEM), and the chemical composition was verified by energy-dispersive X-ray spectroscopy (EDAX). On outside surfaces, the DF post-processing decreased the initial surface roughness by 70–90%. The dental crown’s surface roughness value after DF post-processing was comparable to that of the basic form (cylinder). The lowest roughness was obtained with DF3 post-processing (Ra~0.60 μm). The inner surfaces were limitedly finished. The 3D surface texture showed that the DF method reduced the height of peaks, uniformizing the surfaces. CMM work compared the deviations between the virtual model and the printed samples before and after DF post-processing. This analysis revealed that dimensional deviations were reduced on the outside crown walls, ranging from +0.01 to +0.05 mm. The laser parameters and the heat treatment applied increased the hardness of CoCr crowns to 520 HV, but the proper DF conditions identified reduced the surface roughness and improved the accuracy. Full article
Show Figures

Figure 1

10 pages, 2292 KB  
Article
Comparison of Different Materials in the Same-Sized Cemented Stems on Periprosthetic Fractures in Bone Models
by Kohei Hashimoto, Yukio Nakamura, Nobunori Takahashi and Takkan Morishima
J. Clin. Med. 2025, 14(8), 2724; https://doi.org/10.3390/jcm14082724 - 15 Apr 2025
Viewed by 604
Abstract
Objective: The increasing number of aging patients with total hip arthroplasties (THA) causes an increased incidence of periprosthetic fractures (PPF). The study aimed to evaluate the impacts of two different materials in the same-sized cemented stems on PPF in bone models. Methods [...] Read more.
Objective: The increasing number of aging patients with total hip arthroplasties (THA) causes an increased incidence of periprosthetic fractures (PPF). The study aimed to evaluate the impacts of two different materials in the same-sized cemented stems on PPF in bone models. Methods: This study compared the maximum rotational torque leading to PPF when stems made of cobalt–chromium–molybdenum (Co–Cr–Mo) alloy and stainless use steel (SUS) were implanted using simulated bone models (Sawbones, 3403). The maximum destruction torque was compared statistically for each material (Co–Cr–Mo alloy vs. SUS stainless steel) in this model, and fracture patterns were examined. Results: The PPF occurred with a spiral propagation from the proximal femur towards the diaphysis, with breakage occurring near the distal end of the stem. There were no significant differences in the destruction torque values between the Co–Cr–Mo alloy (103.0 ± 14.9 Nm) and SUS (98.7 ± 15.1 Nm) samples (p = 0.575). The fractures using the bone models exhibited similar patterns in all specimens, resembling clinical PPF fracture types clinically, specifically Vancouver classification B2. Conclusions: The comparison of the maximum destruction torques of the Co–Cr–Mo alloy and SUS cemented stems in simulating PPF showed no significant differences. The results suggest that the materials of the cemented stems might not significantly affect the occurrence of PPF in THA. Full article
(This article belongs to the Section Orthopedics)
Show Figures

Figure 1

31 pages, 25096 KB  
Article
Study of the Structure and Mechanical Properties of Ti-38Zr-11Nb Alloy
by Konstantin V. Sergienko, Sergei V. Konushkin, Yaroslava A. Morozova, Mikhail A. Kaplan, Artem D. Gorbenko, Boris A. Rumyantsev, Mikhail E. Prutskov, Evgeny E. Baranov, Elena O. Nasakina, Tatiana M. Sevostyanova, Sofia A. Mikhlik, Andrey P. Chizhikov, Lyudmila A. Shatova, Aleksandr V. Simakin, Ilya V. Baimler, Maria A. Sudarchikova, Mikhail L. Kheifetz, Alexey G. Kolmakov and Mikhail A. Sevostyanov
J. Funct. Biomater. 2025, 16(4), 126; https://doi.org/10.3390/jfb16040126 - 2 Apr 2025
Viewed by 730
Abstract
Hip joint implants are among the most prevalent types of medical implants utilized for the replacement of damaged joints. The utilization of modern implant materials, such as cobalt–chromium alloys, stainless steel, titanium, and other titanium alloys, is accompanied by challenges, including the toxicity [...] Read more.
Hip joint implants are among the most prevalent types of medical implants utilized for the replacement of damaged joints. The utilization of modern implant materials, such as cobalt–chromium alloys, stainless steel, titanium, and other titanium alloys, is accompanied by challenges, including the toxicity of certain elements (e.g., aluminum, vanadium, nickel) and excessive Young’s modulus, which adversely impact biomechanical compatibility. A mismatch between the stiffness of the implant material and the bone tissue, known as stress shielding, can lead to adverse outcomes such as bone resorption and implant loosening. Recent studies have shifted the focus to β-titanium alloys due to their exceptional biocompatibility, corrosion resistance, and low Young’s modulus, which is close to the Young’s modulus of bone tissue (10–30 GPa). In this study, the microstructure, mechanical properties, and phase stability of the Ti-38Zr-11Nb alloy were investigated. Energy dispersion spectrometry was employed to confirm the homogeneous distribution of Ti, Zr, and Nb in the alloy. A subsequent microstructural analysis revealed the presence of elongated β-grains subsequent to rolling and quenching. Furthermore, grinding contributed to the process of recrystallization and the formation of subgrains. X-ray diffraction analysis confirmed the presence of a stable β-phase under any heat treatment conditions, which can be explained by the use of Nb as a β-stabilizer and Zr as a neutral element with a weak β-stabilizing effect in the presence of other β-stabilizers. Furthermore, the modulus of elasticity, as determined by tensile testing, exhibited a decline from 85 GPa to 81 GPa after annealing. Mechanical tests demonstrated a substantial enhancement in tensile strength (from 529 MPa to 628 MPa) concurrent with a 32% reduction in elongation to fracture of the samples. These alterations are attributed to microstructural transformations, including the formation of subgrains and the rearrangement of dislocations. This study’s findings suggest that the Ti-38Zr-11Nb alloy has potential as a material of choice due to its lower Young’s modulus compared to traditional materials and its stable β-phase, which enhances the implant’s durability and reduces the risk of brittle phases forming over time. This study demonstrates that the corrosion resistance of titanium grade 2 and Ti-38Zr-11Nb is comparable. The material in question exhibited no evidence of cytotoxic activity in the context of mammalian cells. Full article
(This article belongs to the Section Bone Biomaterials)
Show Figures

Figure 1

32 pages, 2445 KB  
Review
Toxicity, Irritation, and Allergy of Metal Implants: Historical Perspective and Modern Solutions
by Grzegorz Szczęsny, Mateusz Kopec and Zbigniew L. Kowalewski
Coatings 2025, 15(3), 361; https://doi.org/10.3390/coatings15030361 - 20 Mar 2025
Cited by 6 | Viewed by 5608
Abstract
The widespread adoption of metal implants in orthopaedics and dentistry has revolutionized medical treatments, but concerns remain regarding their biocompatibility, toxicity, and immunogenicity. This study conducts a comprehensive literature review of traditional biomaterials used in orthopaedic surgery and traumatology, with a particular focus [...] Read more.
The widespread adoption of metal implants in orthopaedics and dentistry has revolutionized medical treatments, but concerns remain regarding their biocompatibility, toxicity, and immunogenicity. This study conducts a comprehensive literature review of traditional biomaterials used in orthopaedic surgery and traumatology, with a particular focus on their historical development and biological interactions. Research articles were gathered from PubMed and Web of Science databases using keyword combinations such as “toxicity, irritation, allergy, biomaterials, corrosion, implants, orthopaedic surgery, biocompatible materials, steel, alloys, material properties, applications, implantology, and surface modification”. An initial pool of 400 articles was screened by independent reviewers based on predefined inclusion and exclusion criteria, resulting in 160 relevant articles covering research from 1950 to 2025. This paper explores the electrochemical processes of metals like iron, titanium, aluminium, cobalt, molybdenum, nickel, and chromium post-implantation, which cause ion release and wear debris formation. These metal ions interact with biological molecules, triggering localized irritation, inflammatory responses, and immune-mediated hypersensitivity. Unlike existing reviews, this paper highlights how metal–protein interactions can form antigenic complexes, contributing to delayed hypersensitivity and complications such as peri-implant osteolysis and implant failure. While titanium is traditionally considered bioinert, emerging evidence suggests that under certain conditions, even inert metals can induce adverse biological effects. Furthermore, this review emphasizes the role of oxidative stress, illustrating how metal ion release and systemic toxicity contribute to long-term health risks. It also uncovers the underappreciated genotoxic and cytotoxic effects of metal ions on cellular metabolism, shedding light on potential long-term repercussions. By integrating a rigorous methodological approach with an in-depth exploration of metal-induced biological responses, this paper offers a more nuanced perspective on the complex interplay between metal implants and human biology, advancing the discourse on implant safety and material innovation. Full article
(This article belongs to the Collection Review Papers Collection for Bioactive Coatings)
Show Figures

Figure 1

Back to TopTop