Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (15)

Search Parameters:
Keywords = immobilized emitter

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 4123 KB  
Article
Quantitative Detection of ALP Activity via Electrochemiluminescence Signal Switching on a Biomimetic Zirconia Interface
by Xinyu Lu, Jin Wang, Jiahao Zhou, Wenwen Tu, Junru Zhou and Tianxiang Wei
Chemosensors 2026, 14(4), 98; https://doi.org/10.3390/chemosensors14040098 - 19 Apr 2026
Viewed by 290
Abstract
Quantitative detection of alkaline phosphatase (ALP) activity is crucial in clinical diagnosis and bioanalysis. Herein, we have developed a highly sensitive electrochemiluminescence (ECL) biosensor that employs a biomimetic zirconia interface as its core sensing platform. The interface was constructed by immobilizing o-phosphorylethanolamine (PEA) [...] Read more.
Quantitative detection of alkaline phosphatase (ALP) activity is crucial in clinical diagnosis and bioanalysis. Herein, we have developed a highly sensitive electrochemiluminescence (ECL) biosensor that employs a biomimetic zirconia interface as its core sensing platform. The interface was constructed by immobilizing o-phosphorylethanolamine (PEA) onto zirconium oxide nanofilms (ZrO2NFs), forming a surface rich in Zr-O-P bonds. This design mimics phosphate recognition and enzyme-triggered dephosphorylation processes, where ALP catalyzes the hydrolysis of these bonds, triggering a direct switch in the ECL signal from Ru(bpy)32+-loaded gold nanocage (Ru-AuNCs) emitters. This sensor achieves a wide linear range of 0.100–100 U/L and a low detection limit down to 0.0899 U/L. Its practical utility was validated through the accurate detection of ALP in fetal bovine serum samples, confirming high recovery and reliability. This strategy highlights the potential of biomimetic zirconia interfaces in developing robust biosensors for early disease diagnosis. Full article
(This article belongs to the Special Issue Electrochemical Biosensors for Global Health Challenges)
Show Figures

Figure 1

16 pages, 1696 KB  
Article
Evaluation of Daughter Radionuclide Release from the 103Pd/103mRh In Vivo Generator for Targeted Auger Therapy
by Aicha Nour Laouameria, Cathryn H. S. Driver, Monika Buys, Elena Sergeevna Kurakina, Mátyás Hunyadi, Jan Rijn Zeevaart and Zoltan Szucs
Pharmaceuticals 2026, 19(1), 126; https://doi.org/10.3390/ph19010126 - 11 Jan 2026
Viewed by 739
Abstract
Background/Objectives: The 103Pd/103mRh in vivo generator represents a promising Auger electron-emitting system, in which both parent and daughter radionuclides emit predominantly Auger electrons with minimal accompanying radiation. This study investigates the release dynamics of daughter radionuclides from the 103 [...] Read more.
Background/Objectives: The 103Pd/103mRh in vivo generator represents a promising Auger electron-emitting system, in which both parent and daughter radionuclides emit predominantly Auger electrons with minimal accompanying radiation. This study investigates the release dynamics of daughter radionuclides from the 103Pd/103mRh in vivo generator and evaluates the underlying mechanisms governing bond rupture and daughter retention. Methods: Cyclotron irradiation of rhodium foils was performed in two separate batches, followed by radionuclide separation using conventional wet chemistry and a novel dry distillation technique. The purified 103Pd radionuclide was used to radiolabel DOTA-TATE, phthalocyanine-TATE, and DOTA-TOC chelators. The resulting complexes were immobilized on Strata-X and Strata-C18 solid-phase extraction columns. Scheduled elution experiments were conducted to quantify the release of the 103mRh daughter radionuclide. Results: The measured 103mRh release rates were 9.8 ± 3.0% and 9.6 ± 2.7% from Strata-X columns with DOTA-TATE and phthalocyanine-TATE, respectively, and 10.5 ± 2.7% and 12.0 ± 0.5% from Strata-X and Strata-C18 columns, respectively, with DOTA-TOC. These values are significantly lower than the ~100% release predicted based on the reported Auger electron yield of 186%. One explanation for this difference could be potential inconsistencies in decay data that may require correction; this needs further investigation. The results further demonstrated that delocalized π-electrons, introduced via phthalocyanine-based chelation, did not mitigate daughter release. Conclusions: The low observed daughter nuclide release represents a favorable characteristic for the future clinical translation of the 103Pd/103mRh Auger emitter pair. The findings support the conclusion that Auger electron cascades, rather than nuclear recoil energy, dominate bond rupture processes. Full article
(This article belongs to the Special Issue Advances in Theranostic Radiopharmaceuticals)
Show Figures

Graphical abstract

15 pages, 2677 KB  
Article
Enzyme-Based Solid-Phase Electrochemiluminescence Sensors with Stable, Anchored Emitters for Sensitive Glucose Detection
by Chunyin Wei, Yanyan Zheng, Fei Yan and Lifang Xu
Biosensors 2025, 15(5), 332; https://doi.org/10.3390/bios15050332 - 21 May 2025
Cited by 15 | Viewed by 1568
Abstract
Glucose (Glu) detection, as a fundamental analytical technique, has applications in medical diagnostics, clinical testing, bioanalysis and environmental monitoring. In this work, a solid-phase electrochemiluminescence (ECL) enzyme sensor was developed by immobilizing the ECL emitter in a stable manner within bipolar silica nanochannel [...] Read more.
Glucose (Glu) detection, as a fundamental analytical technique, has applications in medical diagnostics, clinical testing, bioanalysis and environmental monitoring. In this work, a solid-phase electrochemiluminescence (ECL) enzyme sensor was developed by immobilizing the ECL emitter in a stable manner within bipolar silica nanochannel array film (bp-SNA), enabling sensitive glucose detection. The sensor was constructed using an electrochemical-assisted self-assembly (EASA) method with various siloxane precursors to quickly modify the surface of indium tin oxide (ITO) electrodes with a bilayer SNA of different charge properties. The inner layer, including negatively charged SNA (n-SNA), attracted the positively charged ECL emitter tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) via electrostatic interaction, while the outer layer, including positively charged SNA (p-SNA), repelled it, forming a barrier that efficiently concentrated the Ru(bpy)32+ emitter in a stable manner. After modifying the amine groups on the p-SNA surface with aldehyde groups, glucose oxidase (GOx) was covalently immobilized, forming the enzyme electrode. In the presence of glucose, GOx catalyzed the conversion of glucose to hydrogen peroxide (H2O2), which acted as a quencher for the Ru(bpy)32+/triethanolamine (TPA) system, reducing the ECL signal and enabling quantitative glucose analysis. The sensor exhibited a wide linear range from 10 μM to 7.0 mM and a limit of detection (LOD) of 1 μM (S/N = 3). Glucose detection in fetal bovine serum was realized. By replacing the enzyme type on the electrode surface, this sensing strategy holds the potential to provide a universal platform for the detection of different metabolites. Full article
(This article belongs to the Special Issue Recent Developments in Nanomaterial-Based Electrochemical Biosensors)
Show Figures

Figure 1

12 pages, 3280 KB  
Article
A Dual-Signal Electrochemiluminescence Sensor for Kanamycin Detection Based on a Self-Enhanced Zr MOF and Single Co-Reactant Competition Mechanism
by Yawen Zhu, Xuemei Wang, Zhiyong Yan, Feifei Zhang, Jianfei Xia, Lili Lv and Zonghua Wang
Biosensors 2025, 15(5), 291; https://doi.org/10.3390/bios15050291 - 5 May 2025
Cited by 8 | Viewed by 1639
Abstract
The dual-signal output self-calibration mode reduces the false positive and negative signals of electrochemiluminescence (ECL) aptamer sensors. A competitive dual-signal ECL platform was designed for the ultrasensitive detection of kanamycin (KAN) using a zirconium metal–organic framework (Zr MOF) and Luminol as ECL emitters. [...] Read more.
The dual-signal output self-calibration mode reduces the false positive and negative signals of electrochemiluminescence (ECL) aptamer sensors. A competitive dual-signal ECL platform was designed for the ultrasensitive detection of kanamycin (KAN) using a zirconium metal–organic framework (Zr MOF) and Luminol as ECL emitters. To enhance the ECL efficiency, a co-reactant (polyethyleneimine, PEI) was covalently bound to the Zr MOF to achieve self-enhanced ECL. Based on the selective interaction between KAN and its aptamer, the Luminol/KAN/Zr MOF-PEI “sandwich” structure was immobilized on the electrode surface. The competition for PEI between emitters increased the Luminol ECL signal and decreased the Zr MOF’s ECL signal. The ratio in ECL signals between the two competitive emitters enabled the quantitative analysis of KAN, achieving a detection limit as low as 7.86 × 10−4 ng/mL. This study elucidated the synergistic mechanism between self-enhanced ECL and ECL competition, offering a novel approach for constructing dual-signal ECL sensors using a single co-reactant. Full article
(This article belongs to the Special Issue Progress in Electrochemiluminescence Biosensors)
Show Figures

Figure 1

12 pages, 7574 KB  
Article
Deterministic Fabrication of Fluorescent Nanostructures Featuring Distinct Optical Transitions
by Marijn Rikers, Ayesheh Bashiri, Ángela Barreda, Michael Steinert, Duk-Yong Choi, Thomas Pertsch and Isabelle Staude
Nanomaterials 2025, 15(3), 219; https://doi.org/10.3390/nano15030219 - 29 Jan 2025
Cited by 1 | Viewed by 1552
Abstract
The precise and deterministic integration of fluorescent emitters with photonic nanostructures is an important challenge in nanophotonics and key to the realization of hybrid photonic systems, supporting effects such as emission enhancement, directional emission, and strong coupling. Such integration typically requires the definition [...] Read more.
The precise and deterministic integration of fluorescent emitters with photonic nanostructures is an important challenge in nanophotonics and key to the realization of hybrid photonic systems, supporting effects such as emission enhancement, directional emission, and strong coupling. Such integration typically requires the definition or immobilization of the emitters at defined positions with nanoscale precision. While various methods were already developed for creating localized emitters, in this work we present a new method for the deterministic fabrication of fluorescent nanostructures featuring well-defined optical transitions; it works with a minimal amount of steps and is scalable. Specifically, electron-beam lithography is used to directly pattern a mixture of the negative-tone electron-beam resist with the europium complex Eu(TTA)3, which exhibits both electric and magnetic dipolar transitions. Crucially, the lithography process enables precise control over the shape and position of the resulting fluorescent structures with a feature size of approx. 100 nm. We demonstrate that the Eu(TTA)3 remains fluorescent after exposure, confirming that the electron beam does not alter the structure the optical transitions. This work supports the experimental study of local density of optical states in nanophotonics. It also expands the knowledge base of fluorescent polymer materials, which can have applications in polymer-based photonic devices. Altogether, the presented fabrication method opens the door for the realization of hybrid nanophotonic systems incorporating fluorescent emitters for light-emitting dielectric metasurfaces. Full article
(This article belongs to the Section Nanofabrication and Nanomanufacturing)
Show Figures

Figure 1

16 pages, 5129 KB  
Article
Enhanced Electrochemiluminescence of Luminol and-Dissolved Oxygen by Nanochannel-Confined Au Nanomaterials for Sensitive Immunoassay of Carcinoembryonic Antigen
by Weibin Li, Ruliang Yu and Fengna Xi
Molecules 2024, 29(20), 4880; https://doi.org/10.3390/molecules29204880 - 15 Oct 2024
Cited by 14 | Viewed by 3423
Abstract
Simple development of an electrochemiluminescence (ECL) immunosensor for convenient detection of tumor biomarker is of great significance for early cancer diagnosis, treatment evaluation, and improving patient survival rates and quality of life. In this work, an immunosensor is demonstrated based on an enhanced [...] Read more.
Simple development of an electrochemiluminescence (ECL) immunosensor for convenient detection of tumor biomarker is of great significance for early cancer diagnosis, treatment evaluation, and improving patient survival rates and quality of life. In this work, an immunosensor is demonstrated based on an enhanced ECL signal boosted by nanochannel-confined Au nanomaterial, which enables sensitive detection of the tumor biomarker—carcinoembryonic antigen (CEA). Vertically-ordered mesoporous silica film (VMSF) with a nanochannel array and amine groups was rapidly grown on a simple and low-cost indium tin oxide (ITO) electrode using the electrochemically assisted self-assembly (EASA) method. Au nanomaterials were confined in situ on the VMSF through electrodeposition, which catalyzed both the conversion of dissolved oxygen (O2) to reactive oxygen species (ROS) and the oxidation of a luminol emitter and improved the electrode active surface. The ECL signal was enhanced fivefold after Au nanomaterial deposition. The recognitive interface was fabricated by covalent immobilization of the CEA antibody on the outer surface of the VMSF, followed with the blocking of non-specific binding sites. In the presence of CEA, the formed immunocomplex reduced the diffusion of the luminol emitter, resulting in the reduction of the ECL signal. Based on this mechanism, the constructed immunosensor was able to provide sensitive detection of CEA ranging from 1 pg·mL−1 to 100 ng·mL−1 with a low limit of detection (LOD, 0.37 pg·mL−1, S/N = 3). The developed immunosensor exhibited high selectivity and good stability. ECL determination of CEA in fetal bovine serum was achieved. Full article
Show Figures

Figure 1

13 pages, 3302 KB  
Article
Solid-Phase Electrochemiluminescence Enzyme Electrodes Based on Nanocage Arrays for Highly Sensitive Detection of Cholesterol
by Xinying Ma, Zhe Zhang, Yanyan Zheng and Jiyang Liu
Biosensors 2024, 14(8), 403; https://doi.org/10.3390/bios14080403 - 21 Aug 2024
Cited by 34 | Viewed by 2733
Abstract
The convenient and sensitive detection of metabolites is of great significance for understanding human health status and drug development. Solid-phase electrochemiluminescence (ECL) enzyme electrodes show great potential in metabolite detection based on the enzyme-catalyzed reaction product hydrogen peroxide (H2O2). [...] Read more.
The convenient and sensitive detection of metabolites is of great significance for understanding human health status and drug development. Solid-phase electrochemiluminescence (ECL) enzyme electrodes show great potential in metabolite detection based on the enzyme-catalyzed reaction product hydrogen peroxide (H2O2). Herein, a solid-phase ECL enzyme sensor was fabricated based on a confined emitter and an immobilized enzyme using electrostatic nanocage array, constructing a platform for the sensitive detection of cholesterol. The electrostatic cage nanochannel consists of a bipolar and bilayer vertically aligned mesoporous silica film (bp-VMSF). The upper layer of bp-VMSF is an amino-modified, positively charged VMSF (p-VMSF), and the lower layer is a negatively charged VMSF (n-VMSF). The most commonly used ECL probe tris(bipyridine)ruthenium(II) (Ru(bpy)32+) is fixed in n-VMSF by electrostatic adsorption from n-VMSF and electrostatic repulsion from the upper p-VMSF, generating significantly enhanced and stable ECL signals. The successful preparation of the electrostatic cage was characterized by scanning electron microscopy (SEM) and electrochemical methods. After amino groups on the outer surface of bp-VMSF were derivatized with aldehyde, cholesterol oxidase (ChOx) molecules were covalently immobilized. The successful construction of the enzyme electrode was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). When the corresponding enzyme substrate, cholesterol, was present in the solution, the ECL signal of Ru(bpy)32+ was quenched by the enzyme-catalyzed reaction product H2O2, enabling the high-sensitivity detection of cholesterol. The linear range for detecting cholesterol was from 0.05 mM to 5.0 mM, with a limit of detection (LOD) of 1.5 μM. Full article
Show Figures

Figure 1

15 pages, 4190 KB  
Article
Solid Electrochemiluminescence Sensor by Immobilization of Emitter Ruthenium(II)tris(bipyridine) in Bipolar Silica Nanochannel Film for Sensitive Detection of Oxalate in Serum and Urine
by Ruliang Yu, Yujiao Zhao and Jiyang Liu
Nanomaterials 2024, 14(5), 390; https://doi.org/10.3390/nano14050390 - 20 Feb 2024
Cited by 36 | Viewed by 3096
Abstract
Convenient and highly sensitive detection of oxalate ions in body fluids is of crucial significance for disease prevention, diagnosis, and monitoring of treatment effectiveness. Establishing a simple solid-state electrochemiluminescence (ECL) sensing system for highly sensitive detection of oxalate ions is highly desirable. In [...] Read more.
Convenient and highly sensitive detection of oxalate ions in body fluids is of crucial significance for disease prevention, diagnosis, and monitoring of treatment effectiveness. Establishing a simple solid-state electrochemiluminescence (ECL) sensing system for highly sensitive detection of oxalate ions is highly desirable. In this work, a solid ECL sensor was fabricated by immobilizing the commonly used emitter ruthenium(II)tris(bipyridine) (Ru(bpy)32+) on a double-layered bipolar silica nanochannel array film (bp-SNA)-modified electrode, enabling sensitive detection of oxalate ions in serum or urine samples. Cost-effective and readily available indium tin oxide (ITO) was used as the supporting electrode. Convenient fabrication of multiple negatively charged SNA (n-SNA)-modified ITO electrodes was achieved through the one-step Stöber solution growth method. Subsequently, a positive outer layer film (p-SNA) was rapidly prepared using an electrochemical-assisted self-assembly method. The double-layered bipolar silica nanochannel array film achieved stable immobilization of Ru(bpy)32+ on the electrode surface, facilitated by the electrostatic adsorption of Ru(bpy)32+ by n-SNA and the electrostatic repulsion by p-SNA. Utilizing oxalate ions as a co-reactant for Ru(bpy)32+, combined with the electrostatic enrichment of oxalate ions by p-SNA, the constructed sensor enabled highly sensitive detection of oxalate ions ranging from 1 nM to 25 μM and from 25 μM to 1 mM, with a detection limit (LOD) of 0.8 nM. The fabricated ECL sensor exhibited high selectivity and good stability, making it suitable for ECL detection of oxalate ions in serum and urine samples. Full article
Show Figures

Figure 1

16 pages, 3098 KB  
Article
The Fabrication of a Probe-Integrated Electrochemiluminescence Aptasensor Based on Double-Layered Nanochannel Array with Opposite Charges for the Sensitive Determination of C-Reactive Protein
by Feng Li, Qianqian Han and Fengna Xi
Molecules 2023, 28(23), 7867; https://doi.org/10.3390/molecules28237867 - 30 Nov 2023
Cited by 27 | Viewed by 2308
Abstract
The effective and sensitive detection of the important biomarker, C-reactive protein (CRP), is of great significance in clinical diagnosis. The development of a convenient and highly sensitive electrochemiluminescence (ECL) aptasensor with an immobilized emitter probe is highly desirable. In this work, a probe-integrated [...] Read more.
The effective and sensitive detection of the important biomarker, C-reactive protein (CRP), is of great significance in clinical diagnosis. The development of a convenient and highly sensitive electrochemiluminescence (ECL) aptasensor with an immobilized emitter probe is highly desirable. In this work, a probe-integrated ECL aptamer sensor was constructed based on a bipolar silica nanochannel film (bp-SNF) modified electrode for the highly sensitive ECL detection of CRP. The bp-SNF, modified on an ITO electrode, consisted of a dual-layered SNF film, including the negatively charged inner SNF (n-SNF) and the outer SNF with a positive charge and amino groups (p-SNF). The ECL emitter, tris(bipyridine) ruthenium (II) (Ru(bpy)32+), was stably immobilized in a nanochannel of bp-SNF using the dual electrostatic interactions with n-SNF attracting and p-SNF repelling. The amino groups on the outer surface of bp-SNF were aldehyde derivatized, allowing for the covalent immobilization of recognitive aptamers (5′-NH2-CGAAGGGGATTCGAGGGGTGATTGCGTGCTCCATTTGGTG-3′), leading to the recognition interface. When CRP bound to the aptamer on the recognition interface, the formed complex increased the interface resistance and reduced the diffusion of the co-reactant tripropylamine (TPA) into the nanochannels, leading to a decrease in the ECL signal. Based on this mechanism, the constructed aptamer sensor could achieve a sensitive ECL detection of CRP ranging from 0.01 to 1000 ng/mL, with a detection limit (DL) of 8.5 pg/mL. The method for constructing this probe-integrated ECL aptamer sensor is simple, and it offers a high probe stability, good selectivity, and high sensitivity. Full article
(This article belongs to the Special Issue Biosensors for Molecules Detection)
Show Figures

Graphical abstract

18 pages, 6159 KB  
Article
Electrochemiluminescence Aptasensor with Dual Signal Amplification by Silica Nanochannel-Based Confinement Effect on Nanocatalyst and Efficient Emitter Enrichment for Highly Sensitive Detection of C-Reactive Protein
by Ning Ma, Shuai Xu, Weidong Wu and Jiyang Liu
Molecules 2023, 28(22), 7664; https://doi.org/10.3390/molecules28227664 - 19 Nov 2023
Cited by 17 | Viewed by 2985
Abstract
The rapid and sensitive detection of the important biomarker C-reactive protein (CRP) is of great significance for monitoring inflammation and tissue damage. In this work, an electrochemiluminescence (ECL) aptasensor was fabricated based on dual signal amplification for the sensitive detection of CRP in [...] Read more.
The rapid and sensitive detection of the important biomarker C-reactive protein (CRP) is of great significance for monitoring inflammation and tissue damage. In this work, an electrochemiluminescence (ECL) aptasensor was fabricated based on dual signal amplification for the sensitive detection of CRP in serum samples. The sensor was constructed by modifying a silica nanochannel array film (SNF) on a cost-effective indium tin oxide (ITO) electrode using the Stöber solution growth method. Gold nanoparticles (AuNPs) were grown in situ within the nanochannels using a simple electrodeposition method as a nanocatalyst to enhance the active electrode area as well as the ECL signal. The negatively charged nanochannels also significantly enriched the positively charged ECL emitters, further amplifying the signal. The recognition aptamer was covalently immobilized on the outer surface of SNF after modification with epoxy groups, constructing the aptasensor. In the presence of CRP, the formation of complexes on the recognitive interface led to a decrease in the diffusion of ECL emitters and co-reactants to the supporting electrode, resulting in a reduction in the ECL signal. Based on this mechanism, ECL detection of CRP was achieved with a linear range of 10 pg/mL to 1 μg/mL and a low limit of detection (7.4 pg/mL). The ECL aptasensor developed in this study offers advantages such as simple fabrication and high sensitivity, making promising applications in biomarker detection. Full article
(This article belongs to the Special Issue Aptamer Generation and Bioapplication)
Show Figures

Graphical abstract

15 pages, 4306 KB  
Article
Immunosensor with Enhanced Electrochemiluminescence Signal Using Platinum Nanoparticles Confined within Nanochannels for Highly Sensitive Detection of Carcinoembryonic Antigen
by Huihua Zhang, Chaoyan Zhang, Hui Qu and Fengna Xi
Molecules 2023, 28(18), 6559; https://doi.org/10.3390/molecules28186559 - 11 Sep 2023
Cited by 18 | Viewed by 3911
Abstract
Rapid, highly sensitive, and accurate detection of tumor biomarkers in serum is of great significance in cancer screening, early diagnosis, and postoperative monitoring. In this study, an electrochemiluminescence (ECL) immunosensing platform was constructed by enhancing the ECL signal through in situ growth of [...] Read more.
Rapid, highly sensitive, and accurate detection of tumor biomarkers in serum is of great significance in cancer screening, early diagnosis, and postoperative monitoring. In this study, an electrochemiluminescence (ECL) immunosensing platform was constructed by enhancing the ECL signal through in situ growth of platinum nanoparticles (PtNPs) in a nanochannel array, which can achieve highly sensitive detection of the tumor marker carcinoembryonic antigen (CEA). An inexpensive and readily available indium tin oxide (ITO) glass electrode was used as the supporting electrode, and a layer of amino-functionalized vertically ordered mesoporous silica film (NH2-VMSF) was grown on its surface using an electrochemically assisted self-assembly method (EASA). The amino groups within the nanochannels served as anchoring sites for the one-step electrodeposition of PtNPs, taking advantage of the confinement effect of the ultrasmall nanochannels. After the amino groups on the outer surface of NH2-VMSF were derivatized with aldehyde groups, specific recognition antibodies were covalently immobilized followed by blocking nonspecific binding sites to create an immunorecognition interface. The PtNPs, acting as nanocatalysts, catalyzed the generation of reactive oxygen species (ROS) with hydrogen peroxide (H2O2), significantly enhancing the ECL signal of the luminol. The ECL signal exhibited high stability during continuous electrochemical scanning. When the CEA specifically bound to the immunorecognition interface, the resulting immune complexes restricted the diffusion of the ECL emitters and co-reactants towards the electrode, leading to a reduction in the ECL signal. Based on this immune recognition-induced signal-gating effect, the immunosensor enabled ECL detection of CEA with a linear range of 0.1 pg mL−1 to 1000 ng mL−1 with a low limit of detection (LOD, 0.03 pg mL−1). The constructed immunosensor demonstrated excellent selectivity and can achieve CEA detection in serum. Full article
(This article belongs to the Special Issue Sensors and Analytical Techniques in Biochemistry)
Show Figures

Figure 1

11 pages, 2813 KB  
Communication
Development of Lectin Modified Fluorescent Magnetic Particles for Highly Sensitive Detection of Glycoconjugates
by Yoshio Suzuki
Sensors 2021, 21(16), 5512; https://doi.org/10.3390/s21165512 - 17 Aug 2021
Cited by 4 | Viewed by 3487
Abstract
I conducted this study to develop an improved method for glycome detection using fluorescent magnetic beads, whose surfaces were modified using lectins, for the highly sensitive detection of saccharides or glycoproteins via fluorescence quenching using a novel fluorescence emitter and quencher pair. The [...] Read more.
I conducted this study to develop an improved method for glycome detection using fluorescent magnetic beads, whose surfaces were modified using lectins, for the highly sensitive detection of saccharides or glycoproteins via fluorescence quenching using a novel fluorescence emitter and quencher pair. The emitter (Cy3 fluorophore) was incorporated into magnetic beads, and a fluorescence quencher (cyanopyranyl group) was bound to glycomes via covalent bonding. The fluorescence intensities of fluorescent magnetic beads containing lectins decreased specifically in the presence of glycomes, which was a result of fluorescence quenching from Cy3 to cyanopyranyl groups due to the formation of a stable complex between lectins and glycome. Fluorescence intensities were plotted as a function of glycoprotein concentration, and good linear relationships were observed. This method enabled the fluorescent reading-out of a series of lectin-glycome interactions on the basis of recognition selectivity and affinity of immobilized lectins without tedious washing processes. Moreover, a simple profiling process was performed using this assay for diverse glycoconjugates, which not only included simple saccharides but also glycoproteins and glycome in cell lysates. These results clearly indicate that the combination of magnetic beads with the novel emitter-quencher pair enabled the highly sensitive detection of lectin-glycome interactions. Full article
(This article belongs to the Special Issue Fluorescence and Chemical Luminescence Sensors)
Show Figures

Figure 1

11 pages, 4600 KB  
Article
Surface Alteration of Borosilicate and Phosphate Nuclear Waste Glasses by Hydration and Irradiation
by Bella Y. Zubekhina, Boris E. Burakov and Michael I. Ojovan
Challenges 2020, 11(2), 14; https://doi.org/10.3390/challe11020014 - 23 Jul 2020
Cited by 20 | Viewed by 5144
Abstract
We examined the degradation of nuclear waste borosilicate and phosphate glasses containing strong alpha-emitter 238Pu at a specific activity of 6.33 × 105 MBq/g in comparison with similar non-radioactive, non-radioactive irradiated and radioactive samples containing beta- and gamma-emitters, namely radionuclides 134 [...] Read more.
We examined the degradation of nuclear waste borosilicate and phosphate glasses containing strong alpha-emitter 238Pu at a specific activity of 6.33 × 105 MBq/g in comparison with similar non-radioactive, non-radioactive irradiated and radioactive samples containing beta- and gamma-emitters, namely radionuclides 134Cs and 137Cs. For irradiation and leaching experiments, we used borosilicate and phosphate glasses, which are well-known and currently used to immobilize high-level radioactive waste. The main focus was the observation of the surface of altered glasses. Comparative analysis of hydrolytic surface alteration of borosilicate and phosphate nuclear waste glasses reveals that the behavior of radioactive samples differs significantly from that of non-radioactive glasses. Full article
(This article belongs to the Section Technologies)
Show Figures

Figure 1

17 pages, 3710 KB  
Article
Selective Immobilization of Fluorescent Proteins for the Fabrication of Photoactive Materials
by Ana I. Benítez-Mateos, Ehsan Mehravar, Susana Velasco-Lozano, Radmila Tomovska, Luca Salassa and Fernando López-Gallego
Molecules 2019, 24(15), 2775; https://doi.org/10.3390/molecules24152775 - 30 Jul 2019
Cited by 5 | Viewed by 4625
Abstract
The immobilization of fluorescent proteins is a key technology enabling to fabricate a new generation of photoactive materials with potential technological applications. Herein we have exploited superfolder green (sGFP) and red (RFP) fluorescent proteins expressed with different polypeptide tags. We fused these fluorescent [...] Read more.
The immobilization of fluorescent proteins is a key technology enabling to fabricate a new generation of photoactive materials with potential technological applications. Herein we have exploited superfolder green (sGFP) and red (RFP) fluorescent proteins expressed with different polypeptide tags. We fused these fluorescent proteins to His-tags to immobilize them on graphene 3D hydrogels, and Cys-tags to immobilize them on porous microparticles activated with either epoxy or disulfide groups and with Lys-tags to immobilize them on upconverting nanoparticles functionalized with carboxylic groups. Genetically programming sGFP and RFP with Cys-tag and His-tag, respectively, allowed tuning the protein spatial organization either across the porous structure of two microbeads with different functional groups (agarose-based materials activated with metal chelates and epoxy-methacrylate materials) or across the surface of a single microbead functionalized with both metal-chelates and disulfide groups. By using different polypeptide tags, we can control the attachment chemistry but also the localization of the fluorescent proteins across the material surfaces. The resulting photoactive material formed by His-RFP immobilized on graphene hydrogels has been tested as pH indicator to measure pH changes in the alkaline region, although the immobilized fluorescent protein exhibited a narrower dynamic range to measure pH than the soluble fluorescent protein. Likewise, the immobilization of Lys-sGFP on alginate-coated upconverting nanoparticles enabled the infrared excitation of the fluorescent protein to be used as a green light emitter. These novel photoactive biomaterials open new avenues for innovative technological developments towards the fabrication of biosensors and photonic devices. Full article
(This article belongs to the Special Issue Enzyme Immobilization and Its Applications)
Show Figures

Figure 1

15 pages, 1341 KB  
Article
Trastuzumab-Modified Gold Nanoparticles Labeled with 211At as a Prospective Tool for Local Treatment of HER2-Positive Breast Cancer
by Łucja Dziawer, Agnieszka Majkowska-Pilip, Damian Gaweł, Marlena Godlewska, Marek Pruszyński, Jerzy Jastrzębski, Bogdan Wąs and Aleksander Bilewicz
Nanomaterials 2019, 9(4), 632; https://doi.org/10.3390/nano9040632 - 18 Apr 2019
Cited by 93 | Viewed by 8865
Abstract
Highly localized radiotherapy with radionuclides is a commonly used treatment modality for patients with unresectable solid tumors. Herein, we propose a novel α-nanobrachytherapy approach for selective therapy of human epidermal growth factor receptor 2 (HER2)-positive breast cancer. This uses local intratumoral injection of [...] Read more.
Highly localized radiotherapy with radionuclides is a commonly used treatment modality for patients with unresectable solid tumors. Herein, we propose a novel α-nanobrachytherapy approach for selective therapy of human epidermal growth factor receptor 2 (HER2)-positive breast cancer. This uses local intratumoral injection of 5-nm-diameter gold nanoparticles (AuNPs) labeled with an α-emitter (211At), modified with polyethylene glycol (PEG) chains and attached to HER2-specific monoclonal antibody (trastuzumab). The size, shape, morphology, and zeta potential of the 5 nm synthesized AuNPs were characterized by TEM (Transmission Electron Microscopy) and DLS (Dynamic Light Scattering) techniques. The gold nanoparticle surface was modified by PEG and subsequently used for antibody immobilization. Utilizing the high affinity of gold for heavy halogens, the bioconjugate was labelled with 211At obtained by α irradiation of the bismuth target. The labeling yield of 211At was greater than 99%. 211At bioconjugates were stable in human serum. Additionally, in vitro biological studies indicated that 211At-AuNP-PEG-trastuzumab exhibited higher affinity and cytotoxicity towards the HER2-overexpressing human ovarian SKOV-3 cell line than unmodified nanoparticles. Confocal and dark field microscopy studies revealed that 211At-AuNP-PEG-trastuzumab was effectively internalized and deposited near the nucleus. These findings show promising potential for the 211At-AuNP-PEG-trastuzumab radiobioconjugate as a perspective therapeutic agent in the treatment of unresectable solid cancers expressing HER2 receptors. Full article
(This article belongs to the Special Issue Nanocarriers and Targeted Drug Delivery)
Show Figures

Graphical abstract

Back to TopTop