23 pages, 3443 KB  
Article
Adhesion of Escherichia coli and Lactobacillus fermentum to Films and Electrospun Fibrous Scaffolds from Composites of Poly(3-hydroxybutyrate) with Magnetic Nanoparticles in a Low-Frequency Magnetic Field
by Vera V. Voinova, Vsevolod A. Zhuikov, Yulia V. Zhuikova, Anastasia A. Sorokina, Tatiana K. Makhina, Garina A. Bonartseva, Evgeniia Yu. Parshina, Muhammad Asif Hossain, Konstantin V. Shaitan, Artyom S. Pryadko, Roman V. Chernozem, Yulia R. Mukhortova, Lada E. Shlapakova, Roman A. Surmenev, Maria A. Surmeneva and Anton P. Bonartsev
Int. J. Mol. Sci. 2024, 25(1), 208; https://doi.org/10.3390/ijms25010208 - 22 Dec 2023
Cited by 2 | Viewed by 2956
Abstract
The ability of materials to adhere bacteria on their surface is one of the most important aspects of their development and application in bioengineering. In this work, the effect of the properties of films and electrospun scaffolds made of composite materials based on [...] Read more.
The ability of materials to adhere bacteria on their surface is one of the most important aspects of their development and application in bioengineering. In this work, the effect of the properties of films and electrospun scaffolds made of composite materials based on biosynthetic poly(3-hydroxybutyrate) (PHB) with the addition of magnetite nanoparticles (MNP) and their complex with graphene oxide (MNP/GO) on the adhesion of E. coli and L. fermentum under the influence of a low-frequency magnetic field and without it was investigated. The physicochemical properties (crystallinity; surface hydrophilicity) of the materials were investigated by X-ray structural analysis, differential scanning calorimetry and “drop deposition” methods, and their surface topography was studied by scanning electron and atomic force microscopy. Crystal violet staining made it possible to reveal differences in the surface charge value and to study the adhesion of bacteria to it. It was shown that the differences in physicochemical properties of materials and the manifestation of magnetoactive properties of materials have a multidirectional effect on the adhesion of model microorganisms. Compared to pure PHB, the adhesion of E. coli to PHB-MNP/GO, and for L. fermentum to both composite materials, was higher. In the magnetic field, the adhesion of E. coli increased markedly compared to PHB-MNP/GO, whereas the effect on the adhesion of L. fermentum was reversed and was only evident in samples with PHB-MNP. Thus, the resultant factors enhancing and impairing the substrate binding of Gram-negative E. coli and Gram-positive L. fermentum turned out to be multidirectional, as they probably have different sensitivity to them. The results obtained will allow for the development of materials with externally controlled adhesion of bacteria to them for biotechnology and medicine. Full article
(This article belongs to the Special Issue Polymers in Biological Systems)
Show Figures

Figure 1

18 pages, 6510 KB  
Article
Effect of Fe3O4 Nanoparticles Modified by Citric and Oleic Acids on the Physicochemical and Magnetic Properties of Hybrid Electrospun P(VDF-TrFE) Scaffolds
by Vladimir Botvin, Anastasia Fetisova, Yulia Mukhortova, Dmitry Wagner, Sergey Kazantsev, Maria Surmeneva, Andrei Kholkin and Roman Surmenev
Polymers 2023, 15(14), 3135; https://doi.org/10.3390/polym15143135 - 24 Jul 2023
Cited by 27 | Viewed by 4993
Abstract
This study considers a fabrication of magnetoactive scaffolds based on a copolymer of vinylidene fluoride and trifluoroethylene (P(VDF-TrFE)) and 5, 10, and 15 wt.% of magnetite (Fe3O4) nanoparticles modified with citric (CA) and oleic (OA) acids by solution electrospinning. [...] Read more.
This study considers a fabrication of magnetoactive scaffolds based on a copolymer of vinylidene fluoride and trifluoroethylene (P(VDF-TrFE)) and 5, 10, and 15 wt.% of magnetite (Fe3O4) nanoparticles modified with citric (CA) and oleic (OA) acids by solution electrospinning. The synthesized Fe3O4-CA and Fe3O4-OA nanoparticles are similar in particle size and phase composition, but differ in zeta potential values and magnetic properties. Pure P(VDF-TrFE) scaffolds as well as composites with Fe3O4-CA and Fe3O4-OA nanoparticles demonstrate beads-free 1 μm fibers. According to scanning electron (SEM) and transmission electron (TEM) microscopy, fabricated P(VDF-TrFE) scaffolds filled with CA-modified Fe3O4 nanoparticles have a more homogeneous distribution of magnetic filler due to both the high stabilization ability of CA molecules and the affinity of Fe3O4-CA nanoparticles to the solvent used and P(VDF-TrFE) functional groups. The phase composition of pure and composite scaffolds includes a predominant piezoelectric β-phase, and a γ-phase, to a lesser extent. When adding Fe3O4-CA and Fe3O4-OA nanoparticles, there was no significant decrease in the degree of crystallinity of the P(VDF-TrFE), which, on the contrary, increased up to 76% in the case of composite scaffolds loaded with 15 wt.% of the magnetic fillers. Magnetic properties, mainly saturation magnetization (Ms), are in a good agreement with the content of Fe3O4 nanoparticles and show, among the known magnetoactive PVDF or P(VDF-TrFE) scaffolds, the highest Ms value, equal to 10.0 emu/g in the case of P(VDF-TrFE) composite with 15 wt.% of Fe3O4-CA nanoparticles. Full article
(This article belongs to the Special Issue Development and Application of Polymer Scaffolds)
Show Figures

Figure 1

17 pages, 2730 KB  
Article
Core-Shell Magnetoactive PHB/Gelatin/Magnetite Composite Electrospun Scaffolds for Biomedical Applications
by Artyom S. Pryadko, Vladimir V. Botvin, Yulia R. Mukhortova, Igor Pariy, Dmitriy V. Wagner, Pavel P. Laktionov, Vera S. Chernonosova, Boris P. Chelobanov, Roman V. Chernozem, Maria A. Surmeneva, Andrei L. Kholkin and Roman A. Surmenev
Polymers 2022, 14(3), 529; https://doi.org/10.3390/polym14030529 - 28 Jan 2022
Cited by 42 | Viewed by 5463
Abstract
Novel hybrid magnetoactive composite scaffolds based on poly(3-hydroxybutyrate) (PHB), gelatin, and magnetite (Fe3O4) were fabricated by electrospinning. The morphology, structure, phase composition, and magnetic properties of composite scaffolds were studied. Fabrication procedures of PHB/gelatin and PHB/gelatin/Fe3O4 [...] Read more.
Novel hybrid magnetoactive composite scaffolds based on poly(3-hydroxybutyrate) (PHB), gelatin, and magnetite (Fe3O4) were fabricated by electrospinning. The morphology, structure, phase composition, and magnetic properties of composite scaffolds were studied. Fabrication procedures of PHB/gelatin and PHB/gelatin/Fe3O4 scaffolds resulted in the formation of both core-shell and ribbon-shaped structure of the fibers. In case of hybrid PHB/gelatin/Fe3O4 scaffolds submicron-sized Fe3O4 particles were observed in the surface layers of the fibers. The X-ray photoelectron spectroscopy results allowed the presence of gelatin on the fiber surface (N/C ratio–0.11) to be revealed. Incubation of the composite scaffolds in saline for 3 h decreased the amount of gelatin on the surface by more than ~75%. The differential scanning calorimetry results obtained for pure PHB scaffolds revealed a characteristic melting peak at 177.5 °C. The presence of gelatin in PHB/gelatin and PHB/gelatin/Fe3O4 scaffolds resulted in the decrease in melting temperature to 168–169 °C in comparison with pure PHB scaffolds due to the core-shell structure of the fibers. Hybrid scaffolds also demonstrated a decrease in crystallinity from 52.3% (PHB) to 16.9% (PHB/gelatin) and 9.2% (PHB/gelatin/Fe3O4). All the prepared scaffolds were non-toxic and saturation magnetization of the composite scaffolds with magnetite was 3.27 ± 0.22 emu/g, which makes them prospective candidates for usage in biomedical applications. Full article
(This article belongs to the Topic Advances in Biomaterials)
Show Figures

Graphical abstract

34 pages, 3386 KB  
Review
Tuning the Cell and Biological Tissue Environment through Magneto-Active Materials
by Jorge Gonzalez-Rico, Emanuel Nunez-Sardinha, Leticia Valencia, Angel Arias, Arrate Muñoz-Barrutia, Diego Velasco and Daniel Garcia-Gonzalez
Appl. Sci. 2021, 11(18), 8746; https://doi.org/10.3390/app11188746 - 19 Sep 2021
Cited by 11 | Viewed by 4813
Abstract
This review focuses on novel applications based on multifunctional materials to actuate biological processes. The first section of the work revisits the current knowledge on mechanically dependent biological processes across several scales from subcellular and cellular level to the cell-collective scale (continuum approaches). [...] Read more.
This review focuses on novel applications based on multifunctional materials to actuate biological processes. The first section of the work revisits the current knowledge on mechanically dependent biological processes across several scales from subcellular and cellular level to the cell-collective scale (continuum approaches). This analysis presents a wide variety of mechanically dependent biological processes on nervous system behaviour; bone development and healing; collective cell migration. In the second section, this review presents recent advances in smart materials suitable for use as cell substrates or scaffolds, with a special focus on magneto-active polymers (MAPs). Throughout the manuscript, both experimental and computational methodologies applied to the different treated topics are reviewed. Finally, the use of smart polymeric materials in bioengineering applications is discussed. Full article
(This article belongs to the Special Issue Magnetic Scaffolds for Biomedical Applications)
Show Figures

Figure 1

13 pages, 3974 KB  
Article
Magnetic Bioreactor for Magneto-, Mechano- and Electroactive Tissue Engineering Strategies
by Nelson Castro, Margarida M. Fernandes, Clarisse Ribeiro, Vítor Correia, Rikardo Minguez and Senentxu Lanceros-Méndez
Sensors 2020, 20(12), 3340; https://doi.org/10.3390/s20123340 - 12 Jun 2020
Cited by 37 | Viewed by 6090
Abstract
Biomimetic bioreactor systems are increasingly being developed for tissue engineering applications, due to their ability to recreate the native cell/tissue microenvironment. Regarding bone-related diseases and considering the piezoelectric nature of bone, piezoelectric scaffolds electromechanically stimulated by a bioreactor, providing the stimuli to the [...] Read more.
Biomimetic bioreactor systems are increasingly being developed for tissue engineering applications, due to their ability to recreate the native cell/tissue microenvironment. Regarding bone-related diseases and considering the piezoelectric nature of bone, piezoelectric scaffolds electromechanically stimulated by a bioreactor, providing the stimuli to the cells, allows a biomimetic approach and thus, mimicking the required microenvironment for effective growth and differentiation of bone cells. In this work, a bioreactor has been designed and built allowing to magnetically stimulate magnetoelectric scaffolds and therefore provide mechanical and electrical stimuli to the cells through magnetomechanical or magnetoelectrical effects, depending on the piezoelectric nature of the scaffold. While mechanical bioreactors need direct application of the stimuli on the scaffolds, the herein proposed magnetic bioreactors allow for a remote stimulation without direct contact with the material. Thus, the stimuli application (23 mT at a frequency of 0.3 Hz) to cells seeded on the magnetoelectric, leads to an increase in cell viability of almost 30% with respect to cell culture under static conditions. This could be valuable to mimic what occurs in the human body and for application in immobilized patients. Thus, special emphasis has been placed on the control, design and modeling parameters governing the bioreactor as well as its functional mechanism. Full article
(This article belongs to the Special Issue Electronics for Sensors)
Show Figures

Figure 1

15 pages, 3258 KB  
Article
Morphology Dependence Degradation of Electro- and Magnetoactive Poly(3-hydroxybutyrate-co-hydroxyvalerate) for Tissue Engineering Applications
by Luis Amaro, Daniela M. Correia, Pedro M. Martins, Gabriela Botelho, Sónia A. C. Carabineiro, Clarisse Ribeiro and Senentxu Lanceros-Mendez
Polymers 2020, 12(4), 953; https://doi.org/10.3390/polym12040953 - 20 Apr 2020
Cited by 25 | Viewed by 5004
Abstract
Poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is a piezoelectric biodegradable and biocompatible polymer suitable for tissue engineering applications. The incorporation of magnetostrictive cobalt ferrites (CFO) into PHBV matrix enables the production of magnetically responsive composites, which proved to be effective in the differentiation of a variety of [...] Read more.
Poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is a piezoelectric biodegradable and biocompatible polymer suitable for tissue engineering applications. The incorporation of magnetostrictive cobalt ferrites (CFO) into PHBV matrix enables the production of magnetically responsive composites, which proved to be effective in the differentiation of a variety of cells and tissues. In this work, PHBV and PHBV with CFO nanoparticles were produced in the form of films, fibers and porous scaffolds and subjected to an experimental program allowing to evaluate the degradation process under biological conditions for a period up to 8 weeks. The morphology, physical, chemical and thermal properties were evaluated, together with the weight loss of the samples during the in vitro degradation assays. No major changes in the mentioned properties were found, thus proving its applicability for tissue engineering applications. Degradation was apparent from week 4 and onwards, leading to the conclusion that the degradation ratio of the material is suitable for a large range of tissue engineering applications. Further, it was found that the degradation of the samples maintain the biocompatibility of the materials for the pristine polymer, but can lead to cytotoxic effects when the magnetic CFO nanoparticles are exposed, being therefore needed, for magnetoactive applications, to substitute them by biocompatible ferrites, such as an iron oxide (Fe3O4). Full article
(This article belongs to the Special Issue Advanced Polymeric Biomaterials for Tissue Engineering)
Show Figures

Figure 1