Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (624)

Search Parameters:
Keywords = periimplantitis

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 4612 KB  
Article
Focused Analysis of Complications Associated with Bovine Xenohybrid Bone Grafts Following Maxillary Sinus Augmentation via the Lateral Approach: A Retrospective Cohort Study
by Pascal Grün, Marius Meier, Alexander Anderl, Christoph Kleber, Flora Turhani, Tim Schiepek, S. M. Ragib Shahriar Islam, Sebastian Fitzek, Patrick Bandura and Dritan Turhani
Diagnostics 2025, 15(16), 2089; https://doi.org/10.3390/diagnostics15162089 - 20 Aug 2025
Viewed by 224
Abstract
Background: Maxillary sinus floor augmentation (MSFA) is commonly used to increase posterior maxillary bone volume prior to implant placement. Although generally successful, late complications can impact long-term outcomes. The purpose of the study was to estimate the incidence and timing of atypical [...] Read more.
Background: Maxillary sinus floor augmentation (MSFA) is commonly used to increase posterior maxillary bone volume prior to implant placement. Although generally successful, late complications can impact long-term outcomes. The purpose of the study was to estimate the incidence and timing of atypical late complications following (MSFA) using bovine xenohybrid bone grafts. The study also aimed to evaluate whether preoperative bone volume is associated with the risk of complications. Methods: This retrospective cohort study was conducted at the Center of Oral and Maxillofacial Surgery, Danube Private University, Krems-Stein, Austria, and included patients who underwent MSFA with bovine xenohybrid bone grafts and either simultaneous or staged implant placement between January 2020 and December 2023. Preoperative bone volume of the posterior maxilla measured via cone beam computed tomography (CBCT) in the planned implant insertion position. The primary endpoint was the time (days) from MSFA to the occurrence of a graft-related complication (defined as atypical if occurring more than 6 months after MSFA and not related to peri-implantitis) The covariates included subjects’ age, sex, the quantity of graft used for MSFA, timing of dental implant insertion (simultaneous vs. staged) and implant dimensions. Kaplan–Meier analysis and Cox proportional hazards regression were used to evaluate time-to-event data. Only one graft site per patient was analyzed. Results: Atypical complications occurred in 9 out of 47 patients (19.1%), with an average time to onset of 645 days. In a multivariable analysis, a lower preoperative bone volume was found to be an independent predictor of an increased risk of complications (hazard ratio [HR]: 0.972; 95% confidence interval [CI]: 0.925–1.021; p = 0.252). However, the quantity of graft used for MSFA was not found to be a predictor (p = 0.46). Conclusions: Within the limitations of a retrospective study, reduced native bone volume appears to increase the risk of atypical late complications following MSFA with bovine xenohybrid grafts. This makes closer clinical and radiologic follow-up of patients over a longer period very necessary. Full article
(This article belongs to the Section Medical Imaging and Theranostics)
Show Figures

Figure 1

13 pages, 1358 KB  
Article
A New Method for the Digital Assessment of the Relative Density of Bone Tissue in Dentistry Using the ImageJ Software Package
by Mariya Ebrakhim, Denis Moiseev, Valery Strelnikov, Alaa Salloum, Ekaterina Faustova, Aleksandr Ermolaev, Yulianna Enina, Ellina Velichko and Yuriy Vasil’ev
Dent. J. 2025, 13(8), 375; https://doi.org/10.3390/dj13080375 - 19 Aug 2025
Viewed by 197
Abstract
Backgroud: The aim of this study was to create an accessible, simple and reliable method for assessing the relative density of bone tissue in dentistry based on the analysis of digital panoramic radiographs. Methods: Measurement of average gray values on orthopantomograms [...] Read more.
Backgroud: The aim of this study was to create an accessible, simple and reliable method for assessing the relative density of bone tissue in dentistry based on the analysis of digital panoramic radiographs. Methods: Measurement of average gray values on orthopantomograms was carried out using ImageJ Version 1.54i software. To estimate the relative bone density, functions for selecting regions of interest (ROI), calculating the area of selection, and statistics of the selected area were used. Statistical characteristics of samples and testing of hypotheses using statistical criteria were performed using Microsoft Excel. Results: we found that when manually selecting the reference and comparison areas for areas without signs of pathological changes in bone tissue, the average standard deviation was 0.058, and the coefficient of variation was 0.055 ± 0.011%, which makes the choice of the jaw angle as a reference more preferable. The average relative bone density of the assessed defective areas to the jaw angle was 0.64 ± 0.11, and the average relative bone density of the areas without pathology to the jaw angle was 1.052 ± 0.058. Conclusions: a research protocol was developed and justified using the ImageJ software package, which establishes a strict procedure for quantitative assessment of relative bone density based on the results of digital panoramic radiography. The proposed protocol can be used to monitor the condition of bone tissue after all types of dental treatment over time. Full article
(This article belongs to the Special Issue Digital Implantology in Dentistry)
Show Figures

Figure 1

14 pages, 720 KB  
Article
An Evaluation of the Peri-Implant Tissue in Patients Starting Antiresorptive Agent Treatment After Implant Placement: A Nested Case–Control Study
by Keisuke Seki, Ryo Koyama, Kazuki Takayama, Atsushi Kobayashi, Atsushi Kamimoto and Yoshiyuki Hagiwara
Medicina 2025, 61(8), 1348; https://doi.org/10.3390/medicina61081348 - 25 Jul 2025
Viewed by 248
Abstract
Background and Objectives: We wished to evaluate the effect of antiresorptive agents (ARAs) on peri-implant tissues and to examine the risk factors for peri-implant medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: The study cohort consisted of patients who underwent [...] Read more.
Background and Objectives: We wished to evaluate the effect of antiresorptive agents (ARAs) on peri-implant tissues and to examine the risk factors for peri-implant medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: The study cohort consisted of patients who underwent implant surgery or maintenance treatment between March 2012 and December 2024. The patients were divided into two groups: those in whom bisphosphonates (BPs) or denosumab (Dmab) was used to treat osteoporosis after implant treatment (the ARA group) and a control group. Peri-implant clinical parameters (implant probing depth (iPPD), implant bleeding on probing (iBoP), marginal bone loss (MBL), and mandibular cortical index (MCI)) measured at the baseline and at the final visit were statistically evaluated and compared in both groups. Risk factors were examined using a multivariate analysis of adjusted odds ratios (aORs). Results: A total of 192 implants in 61 patients (52 female, 9 male) were included in this study. The ARA group consisted of 89 implants (22 patients). A comparison of the clinical parameters showed that the ARA group had significantly higher variations in their maximum iPPD and iBoP values over time than those in the control group. Risk factors for peri-implantitis as objective variables were the use of ARAs (aOR: 3.91; 95% confidence interval [CI]: 1.29–11.9) and the change in the maximum iPPD over time (aOR: 1.86; 95% CI: 0.754–4.58). Conclusions: During long-term implant maintenance treatment, patients’ health and medication status change. Monitoring peri-implantitis, the presumed cause of peri-implant MRONJ, is essential, especially in patients who started ARA treatment after implant placement, and special attention should be paid to changes in implant pocket depth. Full article
(This article belongs to the Section Dentistry and Oral Health)
Show Figures

Figure 1

9 pages, 676 KB  
Article
Thermal Effects of Pulsed Infrared Lasers on Zirconia Implants at Different Temperatures In Vitro
by George Kokkinos, Maryam Hafeez, Joseph De Leon and Georgios E. Romanos
Dent. J. 2025, 13(8), 342; https://doi.org/10.3390/dj13080342 - 24 Jul 2025
Viewed by 236
Abstract
Objectives: The aim of this study was to determine the differential temperature produced on ceramic implants using laser irradiation on a pulsed setting of intrabony defects in vitro. Methods: A ceramic (Zr) dental implant (Zeramex, 4.8 × 12 mm) was placed into a [...] Read more.
Objectives: The aim of this study was to determine the differential temperature produced on ceramic implants using laser irradiation on a pulsed setting of intrabony defects in vitro. Methods: A ceramic (Zr) dental implant (Zeramex, 4.8 × 12 mm) was placed into a bovine bone block. A three-wall intrabony defect (6 × 4 × 3 mm) was created to mimic an osseous peri-implant defect. Thermocouples were placed on the apical and coronal areas to measure temperature changes (∆T) during 60 s of laser irradiation. The bovine block was heated to 37 °C, and the defect walls were irradiated with the CO2 and Er,Cr:YSGG laser. The settings used were pulsed mode for both lasers, with 30 Hz and 1.5 W for the Er,Cr:YSGG laser and 70 Hz and 2 W for the CO2 laser. The same laser settings were repeated at room temperature (RT, 23 °C). Twenty trials were performed for each experimental group at room and body temperature for assessment of ∆T. Paired t-test were used to compare the measurements between 37 °C and 23 °C for the Er,Cr:YSGG, and CO2 laser, respectively. Results: The CO2 laser resulted in the highest ∆T (°C) at the coronal (15.22 ± 0.28/8.82 ± 0.21) and apical (5.84 ± 0.14/2.30 ± 0.28) level when this laser was used in both room temperature and body temperature, respectively. The highest ∆T (°C) for the Er,Cr:YSGG laser at body temperature at the coronal thermocouple was 7.64 ± 0.55, while for the CO2 laser, at body temperature was 8.82 ± 0.21. Conclusion: Within the limitations of our study, the use of CO2 laser and Er,Cr:YSGG laser on peri-implant defects generally appears to be safe in treating peri-implant defects around zirconia implants in vitro. Full article
Show Figures

Figure 1

12 pages, 6846 KB  
Case Report
A Second Chance: Managing Late Implant Failure from Peri-Implantitis with Computer-Guided Bone Regeneration—A Clinical Case Report
by Marco Tallarico, Silvio Mario Meloni, Carlotta Cacciò, Francesco Mattia Ceruso and Aurea Immacolata Lumbau
Reports 2025, 8(3), 118; https://doi.org/10.3390/reports8030118 - 22 Jul 2025
Viewed by 535
Abstract
Background and Clinical Significance: The retreatment of failed dental implants remains a challenging clinical scenario, particularly when complicated by peri-implantitis and as sociated bone loss. Successful management requires a comprehensive and predictable approach that addresses both hard and soft tissue deficiencies. Case [...] Read more.
Background and Clinical Significance: The retreatment of failed dental implants remains a challenging clinical scenario, particularly when complicated by peri-implantitis and as sociated bone loss. Successful management requires a comprehensive and predictable approach that addresses both hard and soft tissue deficiencies. Case Presentation: This case report illustrates a fully digital, prosthetically driven workflow for the rehabilitation of a posterior mandibular site following implant failure. A 44-year-old female patient underwent removal of a failing implant and adjacent tooth due to advanced peri-implantitis and periodontitis. After healing, a digital workflow—including intraoral scanning, cone-beam computed tomography (CBCT), and virtual planning—was employed to design and fabricate a customized CAD/CAM titanium mesh for vertical guided bone regeneration. The grafting procedure utilized a composite mixture of autogenous bone and anorganic bovine bone (A-Oss). After nine months of healing, two implants with a hydrophilic surface (SOI) were placed using a fully guided surgical protocol (OneGuide system). Subsequent soft tissue grafting and final prosthetic rehabilitation with monolithic zirconia restorations resulted in stable functional and aesthetic outcomes. Conclusions: This case highlights how the integration of modern digital technologies with advanced regenerative procedures and innovative implant surfaces can enhance the predictability and long-term success of implant retreatment in compromised posterior sites. Full article
(This article belongs to the Section Dentistry/Oral Medicine)
Show Figures

Figure 1

15 pages, 1695 KB  
Article
Reconstructive Therapy in Patients with Peri-Implantitis in a University Dental Hospital: A Preliminary Retrospective Case Series Focusing on Complications
by Ahmad Alahmari, Xavier Costa-Berenguer, Rui Figueiredo, Eduard Valmaseda-Castellón, Alba Sánchez-Torres and Marta García-García
Appl. Sci. 2025, 15(14), 8040; https://doi.org/10.3390/app15148040 - 18 Jul 2025
Viewed by 681
Abstract
Peri-implantitis is an inflammatory disease-causing bone loss around dental implants, often requiring reconstructive surgical therapies to reduce probing depth and regenerate bone. However, such surgeries are frequently complicated by postoperative issues. This retrospective case series aimed to identify the main postoperative complications following [...] Read more.
Peri-implantitis is an inflammatory disease-causing bone loss around dental implants, often requiring reconstructive surgical therapies to reduce probing depth and regenerate bone. However, such surgeries are frequently complicated by postoperative issues. This retrospective case series aimed to identify the main postoperative complications following the reconstructive treatment of peri-implant bone defects in peri-implantitis patients. Data from 14 patients with 21 affected implants were analyzed, including demographics, oral hygiene, surgical techniques, and complications such as wound dehiscence, membrane exposure, and infections. Wound dehiscence was measured using Image J® software version 1.54. Descriptive and bivariate analyses were performed. The results showed that 11 implants (52.4%; 95% confidence interval (95%CI): 29% to 76%) in nine patients (57.1%; 95%CI = 27% to 87%) developed soft tissue dehiscence after one week, with membrane exposure observed in 4 implants. Dehiscence was significantly associated with mandibular implant location (p = 0.003), poor interproximal hygiene (p = 0.008), and membrane exposure (p = 0.034). No postoperative infections were recorded. In conclusion, more than half of peri-implantitis patients undergoing reconstructive surgery experience wound dehiscence, particularly in cases involving mandible, poor hygiene, and membrane exposure. This complication might compromise bone regeneration and reduce the treatment success rate. These results should be interpreted cautiously due to study design limitations (retrospective design, lack of a control group, and small sample size). Full article
(This article belongs to the Special Issue Recent Advances in Digital Dentistry and Oral Implantology)
Show Figures

Figure 1

5 pages, 201 KB  
Editorial
Peri-Implantitis Treatment on Microbial Decontamination
by Maria Pia Di Palo
Microorganisms 2025, 13(7), 1681; https://doi.org/10.3390/microorganisms13071681 - 17 Jul 2025
Viewed by 436
Abstract
Peri-implantitis, as defined by the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions, is a pathological condition affecting the tissues around dental implants, with inflammation in the outer peri-implant tissues and bone loss [...] Full article
24 pages, 9660 KB  
Article
Effect of Mouth Rinsing and Antiseptic Solutions on Periodontitis Bacteria in an In Vitro Oral Human Biofilm Model
by Jan Tinson Strenge, Ralf Smeets, Maria Geffken, Thomas Beikler and Ewa Klara Stuermer
Dent. J. 2025, 13(7), 324; https://doi.org/10.3390/dj13070324 - 16 Jul 2025
Viewed by 582
Abstract
Background/Objectives: The formation of oral biofilms in periodontal pockets and around dental implants with induction of periodontitis or peri-implantitis is an increasing problem in dental health. The intelligent design of a biofilm makes the bacteria embedded in the biofilm matrix highly tolerant [...] Read more.
Background/Objectives: The formation of oral biofilms in periodontal pockets and around dental implants with induction of periodontitis or peri-implantitis is an increasing problem in dental health. The intelligent design of a biofilm makes the bacteria embedded in the biofilm matrix highly tolerant to antiseptic therapy, often resulting in tooth or implant loss. The question therefore arises as to which mouthwashes have eradication potential against oral biofilm. Methods: A human oral biofilm model was developed based on donated blood plasma combined with buffy coats, inoculated with oral pathogenic bacterial species found in periodontal disease (Actinomyces naeslundii, Fusobacterium nucleatum, Streptococcus mitis, and Porphyromonas gingivalis). Over a span of 7 days, we tested different mouth rinsing and antiseptic solutions (Chlorhexidine, Listerine®, NaOCl, Octenisept®, and Octenident®) covering the matured biofilm with 24 h renewal. Phosphate-buffered saline (PBS) was used as a control. Bacterial growth patterns were detected via quantitative polymerase chain reaction (qPCR) after 2, 4, and 7 days of treatment. Results: While all groups showed initial bacterial reduction, the control group demonstrated strong regrowth from day 2 to 4. Listerine showed a near-significant trend toward bacterial suppression. Additionally, strain-specific efficacy was observed, with Octenisept® being most effective against Streptococcus mitis, Octenident® and NaOCl showing superior suppression of Actinomyces naeslundii, and Listerine® outperforming other solutions in reducing Fusobacterium nucleatum. Donor-specific, individual variability further influenced treatment outcomes, with distinct trends in bacterial suppression and regrowth observed across donors. Conclusions: These findings underscore the complexity of biofilm-associated infections and highlight the importance of targeted therapeutic approaches for managing bacterial biofilms. In this experiment, the donor-specific outcomes of the antimicrobial effects of the solutions may indicate that genetic predisposition/tolerance to oral infections appears to play a critical role in the control of oral biofilms. Full article
(This article belongs to the Special Issue Oral Microbiology and Related Research)
Show Figures

Figure 1

22 pages, 2494 KB  
Systematic Review
Reassessing the Use of Membranes in Peri-Implantitis Surgery: A Systematic Review and Meta-Analysis of In Vivo Studies
by Young Joon Cho, Yong Tak Jeong, Hyun Nyun Woo, Hyun Woo Cho, Min Gu Kang, Sung-Min Hwang and Jae-Mok Lee
J. Funct. Biomater. 2025, 16(7), 262; https://doi.org/10.3390/jfb16070262 - 15 Jul 2025
Viewed by 857
Abstract
Peri-implantitis (PI) presents a growing challenge in implant dentistry, with regenerative surgical approaches often incorporating barrier membranes despite the uncertainty of their clinical value. This systematic review and meta-analysis of in vivo studies aimed to evaluate the efficacy of barrier membranes in the [...] Read more.
Peri-implantitis (PI) presents a growing challenge in implant dentistry, with regenerative surgical approaches often incorporating barrier membranes despite the uncertainty of their clinical value. This systematic review and meta-analysis of in vivo studies aimed to evaluate the efficacy of barrier membranes in the reconstructive surgical treatment of PI. A comprehensive electronic search was performed in PubMed, Scopus, Google Scholar, and the Cochrane Library, covering studies published from 1990 to 2024. The protocol followed PRISMA guidelines and was registered in PROSPERO (CRD42025625417). Eligible studies included in vivo investigations comparing regenerative procedures with and without membrane use, with a minimum follow-up of 6 months and at least 10 implants per study. Risk of bias (RoB) was assessed using the Cochrane RoB tool. The meta-analysis was conducted using a random-effects model and included 15 studies comprising 560 patients. Although not consistently statistically significant, the findings suggested that membrane use may offer enhanced outcomes in terms of probing pocket depth (PPD) reduction and marginal bone level (MLB) gain. The evidence was limited by high clinical heterogeneity, variability in outcome definitions, and short follow-up durations. While membranes are commonly utilized, current evidence does not justify their routine use. Further well-designed, long-term clinical trials are needed to establish specific indications and optimize treatment strategies. Full article
(This article belongs to the Special Issue New Biomaterials in Periodontology and Implantology)
Show Figures

Figure 1

14 pages, 5791 KB  
Article
The Trouser Technique: A Novel Approach for Peri-Implant Soft Tissue Augmentation
by Pablo Pavón, Carla Fons-Badal, Natalia Pérez-Rostoll, Jorge Alonso-Pérez-Barquero, María Fernanda Solá-Ruiz and Rubén Agustín-Panadero
J. Clin. Med. 2025, 14(14), 4974; https://doi.org/10.3390/jcm14144974 - 14 Jul 2025
Viewed by 580
Abstract
Background/Objectives: Peri-implant mucosa plays a key role in both peri-implant health and aesthetics. Differences in contour and color between implants and natural teeth can negatively affect patient satisfaction, while soft tissue deficiency may lead to complications such as peri-implantitis. Peri-implant plastic surgery [...] Read more.
Background/Objectives: Peri-implant mucosa plays a key role in both peri-implant health and aesthetics. Differences in contour and color between implants and natural teeth can negatively affect patient satisfaction, while soft tissue deficiency may lead to complications such as peri-implantitis. Peri-implant plastic surgery aims to improve these conditions. The objective of this study is to describe the trouser-shaped connective tissue graft technique designed to enhance vestibular and interproximal peri-implant tissue volume in a single surgical procedure, and to assess its effectiveness and morbidity. Methods: Ten patients requiring soft tissue augmentation in edentulous areas prior to delayed implant placement were selected. Intraoral scanning was performed before and 6 months after treatment to evaluate tissue thickness gain. Results: Significant soft tissue volume gain was observed at both the coronal (mean: 2.74 mm with a 95% confidence interval of 2.21–3.26 mm) and vestibular (mean: 2.79 mm with a 95% confidence interval of 2.24–3.35 mm) levels in all analyzed positions (p < 0.001). The procedure exhibited low morbidity, with minimal complications and discomfort reported by the patients. Conclusions: The trouser-shaped connective tissue graft technique is effective in increasing peri-implant soft tissue. It allows for vestibular and interproximal tissue augmentation in a single procedure, minimizing tissue contraction and morbidity. This technique could be a predictable and minimally invasive alternative for managing volume deficiencies in peri-implant tissues, particularly in aesthetic areas. Full article
(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
Show Figures

Figure 1

16 pages, 950 KB  
Review
High Insertion Torque—Clinical Implications and Drawbacks: A Scoping Review
by Mattia Manfredini, Martina Ghizzoni, Beatrice Cusaro, Mario Beretta, Carlo Maiorana, Francisley Ávila Souza and Pier Paolo Poli
Medicina 2025, 61(7), 1187; https://doi.org/10.3390/medicina61071187 - 30 Jun 2025
Viewed by 618
Abstract
Implant primary stability is a prerequisite for obtaining osseointegration and clinical success. Insertion torque (IT) is measured during implant placement and is expressed in Ncm. It represents the quantification of the frictional force experienced by the implant as it progresses apically through a [...] Read more.
Implant primary stability is a prerequisite for obtaining osseointegration and clinical success. Insertion torque (IT) is measured during implant placement and is expressed in Ncm. It represents the quantification of the frictional force experienced by the implant as it progresses apically through a rotational motion along its axis. Usually, to achieve osseointegration, a value within the range of 20–40 Ncm is desirable. Below a threshold of 20 Ncm, implants have a decrease in survival rate, while implant stability is guaranteed above 20 Ncm. The main goal of this study was to evaluate whether high values of IT affect osseointegration, implant health, and healing, by highlighting the positive and negative effects of IT > 50 Ncm on peri-implant bone, soft tissues, and long-term stability. This scoping review considered randomized clinical trials, observational studies, and cohort studies. Studies failing to meet the predefined inclusion criteria were excluded from the analysis. The review process adhered to the Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) guidelines. Ultimately, a total of 11 studies were included in the final synthesis. Based on the studies included, the literature suggests that high values of IT guarantee adequate primary stability and better osseointegration. However, high IT is significantly associated with greater marginal bone loss, depending on bone density. Accordingly, IT values > 50 Ncm may provoke greater compressive forces with a negative impact on the jawbone. An elevated strain on the bone can induce necrosis and ischemia, due to an alteration of circulation, which in turn is responsible for marginal bone loss and reduced osseointegration. Lack of osseointegration ultimately leads to an early implant failure. As concerns soft tissue recession, a higher decrease is measured in implants placed with high-insertion torque. Nonetheless, additional clinical trials are warranted to assess long-term outcomes, quantify the incidence of these complications, and explore the impact of emerging clinical variables. Full article
(This article belongs to the Special Issue New Regenerative Medicine Strategies in Oral Surgery)
Show Figures

Figure 1

16 pages, 1767 KB  
Article
Peri-Implant Oral Squamous Cell Carcinoma (OSCC): Clinicopathological Features and Staging Issues
by Luisa Limongelli, Fabio Dell’Olio, Antonio D’Amati, Eliano Cascardi, Marta Forte, Rosaria Arianna Siciliani, Alfonso Manfuso, Eugenio Maiorano, Gianfranco Favia, Chiara Copelli and Saverio Capodiferro
Cancers 2025, 17(13), 2149; https://doi.org/10.3390/cancers17132149 - 26 Jun 2025
Viewed by 601
Abstract
Background: Eighty-five percent of peri-implant malignancies are oral squamous cell carcinomas (OSCCs), and most of them are misdiagnosed as peri-implantitis because of their clinical and radiological presentation; few studies have focused on addressing and solving the diagnostic issues related to peri-implant OSCCs. Objectives: [...] Read more.
Background: Eighty-five percent of peri-implant malignancies are oral squamous cell carcinomas (OSCCs), and most of them are misdiagnosed as peri-implantitis because of their clinical and radiological presentation; few studies have focused on addressing and solving the diagnostic issues related to peri-implant OSCCs. Objectives: The study aimed to describe the clinicopathological features of peri-implant OSCCs and to report the staging issues related to the diagnosis of these lesions. Methods: This retrospective cohort study included patients who received a diagnosis of and treatment for peri-implant OSCCs at the Unit of Dentistry of the “Aldo Moro” University of Bari (Italy) from 2018 to 2024. By using descriptive statistics, the authors highlighted the diagnostic issues related to the clinical presentation, radiological features, and histology of peri-implant OSCCs. Results: A total of 13 women and 8 men with a mean age of 70.6 ± 11.7 years met the inclusion criteria; the medical history of the participants showed potentially malignant disorders (OPMDs) in 52.4% of patients, whereas 14.3% had already developed an OSCC. The patients showed 24 peri-implant OSCCs; the clinical presentation was leuko-erythroplakia-like (41.7%) or erythroplakia-like (58.3%), thus simulating peri-implantitis; in addition, 52.0% of dental implants involved had a probing pocket depth ≥ 10 mm, further mimicking peri-implantitis. Panoramic radiograms and cone beam computed tomography were of little use in studying bundle bone–implant interfaces; in particular, the tomography showed circumferential bone resorption only in peri-implantitis-like OSCCs. In total, 91.6% of histological examinations of OSCCs showed peri-implantitis-like inflammation; early-stage lesions (pTNM I-II) accounted for 33.3%, whereas late-stage lesions (pTNM III-IV) accounted for 66.7%; lymph nodal metastases occurred in 25.0% and 62.5%, respectively. The mean follow-up was 3.4 ± 1.0 years; all patients with OPMDs had poorly differentiated tumors and thus showed a worse prognosis than those without OPMDs (mean disease-free survival of 15.5 ± 7.7 months and 44.7 ± 12.1 months, respectively). Conclusions: The results of the study showed that peri-implant OSCCs occurred most frequently in patients with OPMDs or previous OSCC; in addition, peri-implant OSCCs required demolition rather than conservative excision, and the prognosis of patients strictly depended on the grade of the cancer. In the authors’ experience, the clinical–radiological presentation simulating peri-implantitis was the feature that concurred most in complicating the diagnosis of those tumors. Full article
Show Figures

Figure 1

17 pages, 17488 KB  
Article
Effect of Diamond-like Carbon Thin-Film Deposition on the Hardness of Pure Titanium Surfaces
by Hideaki Sato, Yutaka Kameyama, Ryota Yoshikawa, Kaito Tabuchi, Chizuko Ogata and Satoshi Komasa
Materials 2025, 18(13), 2992; https://doi.org/10.3390/ma18132992 - 24 Jun 2025
Viewed by 362
Abstract
The purpose of this study was to clarify the physical durability of a diamond-like carbon (DLC) thin film coated on pure titanium. The titanium surface of the abutment does not have sufficient toughness to prevent an increase in surface roughness or damage when [...] Read more.
The purpose of this study was to clarify the physical durability of a diamond-like carbon (DLC) thin film coated on pure titanium. The titanium surface of the abutment does not have sufficient toughness to prevent an increase in surface roughness or damage when the implant is scaled using a professional mechanical implement. The scaling process used for the removal of the dental plaque adhered to the abutment surface could increase the potential for the deposition of oral microorganisms and the accumulation of plaque, which increase the risk of peri-implantitis. A DLC thin film is biocompatible material that is known for its toughness, including extreme hardness, high abrasion resistance, chemical inertness, and high corrosion resistance. Protecting the abutment surface with the application of a DLC might prevent plaque adhesion due to its non-stick property. There was little change in the surface roughness of titanium samples to which DLC surface protection had been applied when the surface of the sample was scratched with a stainless steel scalar more than a thousand times. When cleaning the surface of pure titanium samples, the surface roughness significantly increased. DLC thin films are effective for the prevention the surface roughness of pure titanium implants from being increased when the conventional cleaning of the surface of the implant is performed. Full article
(This article belongs to the Special Issue Materials for Prosthodontics, Implantology, and Digital Dentistry)
Show Figures

Figure 1

19 pages, 1126 KB  
Review
Exploring the Efficacy of Low-Temperature Plasmas on Oral Biofilms: A Scoping Review
by Carson C. Davis, Fabrízio Dias Panariello and Beatriz Panariello
Med. Sci. 2025, 13(2), 79; https://doi.org/10.3390/medsci13020079 - 18 Jun 2025
Viewed by 864
Abstract
The rise of antibiotic resistance and the limitations of conventional therapies for managing biofilm-related oral infections highlight the urgent need for novel solutions, with low-temperature plasma (LTP) emerging as a promising alternative due to its potent antimicrobial effects, tissue-safety, and reduced risk of [...] Read more.
The rise of antibiotic resistance and the limitations of conventional therapies for managing biofilm-related oral infections highlight the urgent need for novel solutions, with low-temperature plasma (LTP) emerging as a promising alternative due to its potent antimicrobial effects, tissue-safety, and reduced risk of fostering resistance. This scoping review investigates the efficacy of LTP application for the management of oral biofilms associated with dental caries, peri-implantitis, endodontic infections, and oral candidiasis. This review was conducted in accordance with the PRISMA-ScR guidelines and registered with the Open Science Framework (OSF). Studies were identified through comprehensive searches of PubMed/MEDLINE, EBSCO (Medline Ultimate and e-journals), and Google Scholar, with no publication date restrictions, and were supplemented by manual reference screening. Eligible studies included original research, published in English, examining LTP’s effectiveness in oral biofilms. After systematically screening the literature, 51 studies were included in this scoping review, comprising mostly in vitro research, alongside ex vivo, in situ, and clinical studies. Data extraction revealed LTP’s broad-spectrum antimicrobial potential and promising clinical implications for dentistry. This review highlights key findings, identifies research gaps, and underscores the therapeutic potential of LTP in managing complex oral biofilm-related infections. Full article
Show Figures

Figure 1

11 pages, 1142 KB  
Article
Changes in Implant Surface Characteristics and Wettability Induced by Smoking In Vitro: A Preliminary Investigation
by Danielle Ohana, Nina K. Anderson, Rafael Delgado-Ruiz and Georgios E. Romanos
Materials 2025, 18(12), 2844; https://doi.org/10.3390/ma18122844 - 17 Jun 2025
Viewed by 469
Abstract
The biologic response following the insertion of dental implants is a widely studied process. Recent research has highlighted the importance of implant surface topography and chemistry as highly influential factors in consolidating the dental implant with the surrounding biological environment. The hydrophilicity, or [...] Read more.
The biologic response following the insertion of dental implants is a widely studied process. Recent research has highlighted the importance of implant surface topography and chemistry as highly influential factors in consolidating the dental implant with the surrounding biological environment. The hydrophilicity, or wettability, of dental implants plays a pivotal role in these interactions and successful osseointegration. A more well-established factor that can also influence the development of the tissue–implant interface is exposure to tobacco smoke. While the negative impact of smoking on the biological response of the tissue is clear, there has been no research evaluating the impact that tobacco smoke can have directly on the surface chemistry of dental implants. The present study aimed to explore the effect of smoking on implant surface chemistry and wettability in vitro. Five different implant disks (Ti-Mach, Ti-SLA, Ti-Alloy, Zirc-1 and Zirc-2) were subjected to contamination with tobacco smoke using a portable smoke infuser with dome enclosure. Occasional smoking (5×/day 10 min each for 3 days) and heavy smoking (20×/day for 10 min each for 10 days) were simulated. The wettability of the implant disks was evaluated via the contact angle technique using artificial blood and albumin, as well as saline as a control. It was determined that the contamination of implant surfaces due to smoking produces changes in the surface chemistry and wettability. Changes in the surface hydrophilicity differed based on the implant material. Within the constraints of this investigation, tobacco smoke improved the hydrophilicity of titanium surfaces but worsened that of ceramic surfaces when utilizing the testing solutions. Different implant surfaces exhibit different wetting behavior following contamination with nicotine smoke. This might have an impact on the treatment of peri-implantitis in smokers due to changes in implant surface hydrophilicity, which can affect the re-osseointegration process. Full article
(This article belongs to the Section Biomaterials)
Show Figures

Figure 1

Back to TopTop