A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Abstract
:1. Introduction
2. Design Fundamentals for Accelerometry-Based Wearable Motion Detectors
2.1. Accelerometry: Principles and Sensors
2.1.1. Piezoresistive accelerometers
2.1.2. Piezoelectric accelerometers
2.1.3. Differential capacitive accelerometers
2.2. Sensor Placement
3. Capabilities of Wearable Systems Using Accelerometry Measurement
3.1. Posture and Movement Classification
3.2. Estimation of Energy Expenditure
3.3. Fall Detection and Balance Control Evaluation
4. Review of Current Products
(1) SenseWear (BodyMedia Inc.)
(2) CT1 and RT3 (StayHealthy Inc.)
(3) AMP 331 (Dynastream Innovations Inc.)
(4) GT3X, GT1M (ActiGraph LLC)
(5) StepWatch (Orthocare Innovations)
(6) activPAL (PAL Technologies Ltd.)
(7) IDEEA (MiniSun)
5. Conclusions
References
- Caspersen, CJ; Powell, KE; Christenson, GM. Physical activity, exercise and physical fitness: Definitions and distinctions for health-related research. Public. Health. Rep 1985, 110, 126–131. [Google Scholar]
- Steele, BG; Holt, RNL; Belza, B; Ferris, S; Lakshminaryan, S; Buchner, DM. Quantitating physical activity in COPD using a triaxial accelerometer. Chest 2000, 117, 1359–1367. [Google Scholar]
- Meijer, GAL; Westerterp, KR; Verhoeven, FMH; Koper, HBM; Hoor, F. Methods to assess physical activity with special reference to motion sensors and accelerometers. IEEE. Trans. Biomed. Eng 1991, 38, 221–229. [Google Scholar]
- Podsiadlo, D; Richardson, S. The timed “Up & Go”: A test of basic functional mobility for frail elderly persons. J. Am. Geriatr. Soc 1991, 39, 142–148. [Google Scholar]
- Berg, KO; Wood-Dauphinee, SL; Williams, JI; Gayton, D. Measuring balance in elderly: Preliminary development of an instrument. Physiother. Can 1989, 41, 304–311. [Google Scholar]
- Saris, WHM; Binkhorst, RA. The use of pedometer and actometer in studying daily physical activity in man. Part I: Reliability of pedometer and actometer. Eur. J. Appl. Physiol 1977, 37, 219–228. [Google Scholar]
- Chen, KY; Bassett, DR, Jr. The technology of accelerometry-based activity monitors: Current and future. Med. Sci. Sports. Exerc 2005, 37, 490–500. [Google Scholar]
- Mathie, MJ; Coster, ACF; Lovell, NH; Celler, BG. Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement. Physiol. Meas 2004, 25, 1–20. [Google Scholar]
- Saunders, JB; Inman, V; Eberhart, HD. The major determinants in normal and pathological gait. J. Bone. Joint. Surg. Am 1953, 35, 543–558. [Google Scholar]
- Morris, JRW. Accelerometry—A technique for the measurement of human body movement. J. Biomech 1973, 6, 729–736. [Google Scholar]
- Roylance, LM; Angell, JB. A batch-fabricated silicon accelerometer. IEEE. Trans. Electron. Devices 1979, 26, 1911–1917. [Google Scholar]
- Öberg, PÅ; Togawa, T; Spelman, FA. Sensors in Medicine and Health Care; Wiley-VCH. Weinheim: Berlin, Germany, 2004; Volume 1, pp. 245–252. [Google Scholar]
- Godfrey, A; Conway, R; Meagher, D; ÓLaighin, G. Direct measurement of human movement by accelerometry. Med. Eng. Phys 2008, 30, 1364–1386. [Google Scholar]
- Gemperle, F; Kasabach, C; Stivoric, J; Bauer, M; Martin, R. Design for wearability. Proceedings of the 2nd IEEE Symposium on Wearable Computers, Pittsburg, PA, USA, 19–20 October 1998; pp. 116–122.
- Najafi, B; Aminian, K; Paraschiv-Ionescu, A; Loew, F; Büla, CJ; Robert, P. Ambulatory system for human motion analysis using a kinematic sensor: Monitoring of daily physical activity in the elderly. IEEE. Trans. Biomed. Eng 2003, 50, 711–723. [Google Scholar]
- Karantonis, DM; Narayanan, MR; Mathie, M; Lovell, NH; Celler, BG. Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring. IEEE. Trans. Inf. Technol. Biomed 2006, 10, 156–167. [Google Scholar]
- Yang, CC; Hsu, YL. Development of a wearable motion detector for telemonitoring and real-time identification of physical activity. Telemed. J. E. Health 2009, 15, 62–72. [Google Scholar]
- Sekine, M; Tamura, T; Togawa, T; Fukui, Y. Classification of waist-acceleration signals in a continuous walking record. Med. Eng. Phys 2000, 22, 285–291. [Google Scholar]
- Kawada, T; Shimizu, T; Fujii, A; Kuratomi, Y; Suto, S; Kanai, T; Nishime, A; Sato, K; Otsuka, Y. Activity and sleeping time monitored by an accelerometer in rotating shift workers. Work 2008, 30, 157–160. [Google Scholar]
- Liszka-Hackzell, JJ; Martin, DP. Analysis of nighttime activity and daytime pain in patients with chronic back pain using a self-organizing map neural network. J. Clin. Monit. Comput 2005, 19, 411–414. [Google Scholar]
- Morillo, DS; Ojeda, JLR; Foix, LFC; Jiménez, AL. An Accelerometer-based device for sleep apnea screening. IEEE. Trans. Inf. Technol. Biomed 2010, 14, 491–499. [Google Scholar]
- Park, JH; Kim, HJ; Kang, SJ. Validation of the AMP331 monitor for assessing energy expenditure of free-living physical activity. Res. Quart. Exerc. Sport 2006, 77, A40–A40. [Google Scholar]
- Kuo, YL; Culhane, KM; Thomason, P; Tirosh, O; Baker, R. Measuring distance walked and step count in children with cerebral palsy: An evaluation of two portable activity monitors. Gait Posture 2009, 29, 304–310. [Google Scholar]
- Lindemann, U; Hock, A; Stuber, M; Keck, W; Becker, C. Evaluation of a fall detector based on accelerometers: A pilot study. Med. Biol. Eng. Comput 2005, 43, 548–551. [Google Scholar]
- Menz, HB; Lord, SR; Fitzpatrick, C. Age-related differences in walking stability. Age Ageing 2003, 32, 137–142. [Google Scholar]
- Menz, HB; Lord, SR; Fitzpatrick, RC. Acceleration patterns of the head and pelvis when walking are associated with risk of falling in community-dwelling older people. J. Gerontol. A. Biol. Sci. Med. Sci 2003, 58, 446–452. [Google Scholar]
- Noury, N; Dittmar, A; Corroy, C; Baghai, R; Weber, JL; Blanc, D; Klefstat, F; Blinovska, A; Vaysse, S; Comet, B. VTAMN-A smart clothe for ambulatory remote monitoring of physiological parameters and activity. Proceedings of 26th Annual International Conference of the IEEE EMBS, San Francisco, CA, USA, 1–5 September 2004; pp. 3266–3269.
- Kiani, K; Snijders, CJ; Gelsema, ES. Computerized analysis of daily life motor activity for ambulatory monitoring. Technol. Health. Care 1997, 5, 307–318. [Google Scholar]
- Mathie, MJ; Celler, BG; Lovell, NH; Coster, ACF. Classification of basic daily movements using a triaxal accelerometer. Med. Biol. Eng. Comput 2004, 42, 679–687. [Google Scholar]
- Veltink, PH; Bussmann, BJ; de Vries, W; Martens, WL; van Lummel, RC. Detection of static and dynamic activities using uniaxial accelerometers. IEEE. Trans. Rehabil. Eng 1996, 4, 375–385. [Google Scholar]
- Foerster, F; Smeja, M; Fahrenberg, J. Detection of posture and motion by accelerometry: A validation study in ambulatory monitoring. Comput. Human. Behav 1999, 15, 571–583. [Google Scholar]
- Lyons, GM; Culhane, KM; Hilton, D; Grace, PA; Lyons, D. A description of an accelerometer-based mobility monitoring technique. Med. Eng. Phys 2005, 27, 497–504. [Google Scholar]
- Najafi, B; Aminian, K; Loew, F; Blanc, Y; Robert, PA. Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly. IEEE. Trans. Biomed. Eng 2002, 49, 843–851. [Google Scholar]
- Ohtaki, Y; Susumago, M; Suzuki, A; Sagawa, K; Nagatomi, R; Inooka, H. Automatic classification of ambulatory movements and evaluation of energy consumptions utilizing accelerometers and a barometer. Microsyst. Technol 2005, 11, 1034–1040. [Google Scholar]
- Bussmann, HB; Reuvekamp, PJ; Veltink, PH; Martens, WL; Stam, HJ. Validity and reliability of measurements obtained with an “activity monitor” in people with and without a transtibial amputation. Phys. Ther 1998, 78, 989–998. [Google Scholar]
- Lau, HY; Tong, KY; Zhu, H. Support vector machine for classification of walking conditions of persons after stroke with dropped foot. Hum. Mov. Sci 2009, 28, 504–514. [Google Scholar]
- Zhang, T; Wang, J; Xu, L; Liu, P. Fall detection by wearable sensor and one-class SVM algorithm. Intel. Comput. Signal Process. Pattern Recognit 2006, 345, 858–863. [Google Scholar]
- Huynh, T; Schiele, B. Towards less supervision in activity recognition from wearable sensors. Proceedings of the 10th IEEE International Symposium on Wearable Computers, Montreux, Switzerland, 11–14 October 2006; pp. 3–10.
- Long, X; Yin, B; Aarts, RM. Single-accelerometer-based daily physical activity classification. Proceedings of the 31st Annual International Conference of the IEEE EMBS, Minneapolis, MN, USA, 2–6 September 2009; pp. 6107–6110.
- Allen, FR; Ambikairajah, E; Lovell, NH; Celler, BG. Classification of a known sequence of motions and postures from accelerometry data using adapted Gaussian mixture models. Physiol. Meas 2006, 27, 935–951. [Google Scholar]
- Mannini, A; Sabatini, AM. Machine learning methods for classifying human physical activity from On-Body Accelerometers. Sensors 2010, 10, 1154–1175. [Google Scholar]
- Pober, DM; Staudenmayer, J; Raphael, C; Freedson, PS. Development of novel techniques to classify physical activity mode using accelerometers. Med. Sci. Sports Exerc 2006, 38, 1626–1634. [Google Scholar]
- Vanhees, L; Lefevre, J; Philippaerts, R; Martens, M; Huygens, W; Troosters, T; Beunen, G. How to assess physical activity? How to assess physical fitness? Eur. J. Cardiovasc. Prev. Rehabil 2005, 12, 102–114. [Google Scholar]
- Bouten, CV; Westerterp, KR; Verduin, M; Janssen, JD. Assessment of energy expenditure for physical activity using a triaxial accelerometer. Med. Sci. Sports. Exerc 1994, 26, 1516–1523. [Google Scholar]
- Bouten, CV; Koekkoek, KT; Verduin, M; Kodde, R; Janssen, JD. A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity. IEEE. Trans. Biomed. Eng 1997, 44, 136–147. [Google Scholar]
- Plasqui, G; Westerterp, KR. Physical activity assessment with accelerometers: An evaluation against doubly labeled water. Obesity 2007, 15, 2371–2379. [Google Scholar]
- Crouter, SE; Churilla, JR; Bassett, DR. Estimating energy expenditure using accelerometers. Eur. J. Appl. Physiol 2006, 98, 601–612. [Google Scholar]
- Gibson, MJ. The prevention of falls in later life. A report of the Kellogg International Work Group on the prevention of falls by the elderly. Dan Med Bull 1987, 34(4), 1–24. [Google Scholar]
- Williams, G; Doughty, K; Cameron, K; Bradley, DA. A smart fall and activity monitor for telecare applications. Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Hong Kong, 29 October–1 November 1998; pp. 1151–1154.
- Doughty, K; Lewis, R; McIntosh, A. The design of a practical and reliable fall detector for community and institutional telecare. J. Telemed. Telecare 2000, 6, 150–154. [Google Scholar]
- Berg, KO; Maki, BE; Williams, JI; Holliday, PJ; Wood-Dauphinee, SL. Clinical and laboratory measures of postural balance in an elderly population. Arch. Phys. Med. Rehabil 1992, 73, 1073–1080. [Google Scholar]
- Lord, SR; Menz, HB; Tiedemann, A. A physiological profile approach to fall risk assessment and prevention. Phys. Ther 2003, 83, 237–252. [Google Scholar]
- Sherrington, C. The Effect of Exercise on Physical Ability Following Fall-Related Hip fracture. PhD thesis,. University of New South Wales: Sydney, Australia, 2000. [Google Scholar]
- Hageman, PA; Leibowitz, JM; Blanke, D. Age and gender effects on postural control measures. Arch. Phys. Med. Rehabil 1995, 76, 961–965. [Google Scholar]
- Duarte, M; Harvey, W; Zatsiorsky, VM. Stabilographic analysis of unconstrained standing. Ergonomics 2000, 43, 1824–1839. [Google Scholar]
- Nichols, DS; Glenn, TM; Hutchinson, KJ. Changes in the mean center of balance during balance testing in young adults. Phys. Ther 1995, 75, 699–706. [Google Scholar]
- Mayagoitia, RE; Lötters, JC; Veltink, PH; Hermens, H. Standing balance evaluation using a triaxial accelerometer. Gait Posture 2002, 16, 55–59. [Google Scholar]
- Adlerton, AK; Moritz, U; Moe-Nilssen, R. Forceplate and accelerometer measures for evaluating the effect of muscle fatigue on postural control during one-legged stance. Physiother Res Int 2003, 8, 187–199. [Google Scholar]
- Evans, AL; Duncan, G; Gilchrist, W. Recording accelerations in body movement. Med. Biol. Eng. Comput 1991, 29, 102–104. [Google Scholar]
- Auvinet, B; Chaleil, D; Barrey, E. Accelerometric gait analysis for use in hospital outpatients. Rev. Rhum. Engl. Ed 1999, 66, 389–397. [Google Scholar]
- Aminian, K; Rezakhanlou, K; De Andres, E; Fritsch, C; Leyvraz, PF; Robert, P. Temporal feature estimation during walking using miniature accelerometers: An analysis of gait improvement after hip arthroplasty. Med. Biol. Eng. Comput 1999, 37, 686–691. [Google Scholar]
- Aminian, K; Najafi, B; Büla, C; Leyvraz, PF; Robert, P. Spatial-temporal parameters of gait measured by an ambulatory system using miniature gyroscope. J. Biomech 2002, 35, 689–699. [Google Scholar]
- Moe-Nilssen, R; Helbostad, JL. Estimation of gait cycle characteristics by trunk accelerometry. J. Biomech 2004, 37, 121–126. [Google Scholar]
- Moe-Nilssen, R; Helbostad, JL; Talcott, JB; Toennessen, FE. Balance and gait in children with dyslexia. Exp. Brain. Res 2003, 150, 237–244. [Google Scholar]
- Smidt, GL; Arora, JS; Johnston, RC. Accelerometric analysis of several types of walking. Am. J. Phys. Med. Rehabil 1971, 50, 285–300. [Google Scholar]
- Polzien, KM; Jakicic, JM; Tate, DF; Otto, AD. The efficacy of a technology-based system in a short-term behavioral weight loss intervention. Obesity 2007, 15, 825–830. [Google Scholar]
- Arvidsson, D; Slinde, F; Larsson, S. Energy cost in children assessed by multisensory activity monitors. Med. Sci. Sports. Exerc 2009, 41, 603–611. [Google Scholar]
- Jin, GH; Lee, SB; Lee, TS. Context awareness of human motion states using accelerometer. J. Med. Syst 2008, 32, 93–100. [Google Scholar]
- Rowlands, AV; Thomas, PW; Eston, RG; Topping, R. Validation of the RT3 triaxial accelerometer for the assessment of physical activity. Med. Sci. Sports. Exerc 2004, 36, 518–524. [Google Scholar]
- Hecht, A; Ma, S; Porszasz, J; Casaburi, R. Methodology for using long-term accelerometry monitoring to describe daily activity patterns in COPD. COPD J. Chronic Obstructive Pulm. Dis 2009, 6, 121–129. [Google Scholar]
- Barnason, S; Zimmerman, L; Nieveen, J; Schulz, P; Miller, C; Hertzog, M; Tu, C. Influence of a symptom management telehealth intervention on older adults' early recovery outcomes after coronary artery bypass surgery. Heart Lung 2009, 38, 364–376. [Google Scholar]
- Martinez-Gómez, D; Welk, GJ; Calle, ME; Marcos, A; Veiga, OL. Preliminary evidence of physical activity levels measured by accelerometer in Spanish adolescents; the AFINOS Study. Nutr. Hosp 2009, 24, 226–232. [Google Scholar]
- Focht, BC; Sanders, WM; Brubaker, PH; Rejeski, WJ. Initial validation of the CSA activity monitor during rehabilitation exercise among older adults with chronic disease. J. Aging. Phys. Act 2003, 11, 293–304. [Google Scholar]
- de Vries, SI; Bakker, I; Hopman-Rock, M; Hirasing, RA; van Mechelen, W. Clinimetric review of motion sensors in children and adolescents. J. Clin. Epidemiol 2006, 59, 670–680. [Google Scholar]
- García-Ortiz, L; Recio-Rodríguez, JI; Martín-Cantera, C; Cabrejas-Sánchez, A; Gómez-Arranz, A; Gánzalez-Viejo, N; Nicolás, EIS; Patino-Alonso, MC; Gómez-Marcos, MA. Physical exercise, fitness and dietary pattern and their relationship with circadian blood pressure pattern, augmentation index and endothelial dysfunction biological markers: Evident study protocol. BMC. Public Health 2010, 10, 1–8. [Google Scholar]
- Foster, RC; Lanningham-Foster, LM; Manohar, C; McCrady, SK; Nysse, L; Kaufman, KR; Padgett, DJ; Levine, JA. Precision and accuracy of an ankle-worn accelerometer-based pedometer in step counting and energy expenditure. Prev. Med 2005, 41, 778–783. [Google Scholar]
- Storti, KL; Pettee, KK; Brach, JS; Talkowsk, JB; Richardson, CR; Kriska, AM. Gait speed and step-count monitor accuracy in community-dwelling older adults. Med. Sci. Sports Exerc 2008, 40, 59–64. [Google Scholar]
- Karabulut, M; Crouter, SE; Bassett, DR. Comparison of two waist-mounted and two ankle-mounted electronic pedometers. Eur. J. Appl. Physiol 2005, 95, 335–343. [Google Scholar]
- Ryan, CG; Grant, PM; Tigbe, WW; Granat, MH. The validity and reliability of a novel activity monitor as a measure of walking. Br. J. Sports. Med 2006, 40, 779–784. [Google Scholar]
- Godfrey, A; Culhane, KM; Lyons, GM. Comparison of the performance of the activPAL(TM) Professional physical activity logger to a discrete accelerometer-based activity monitor. Med. Eng. Phys 2007, 29, 930–934. [Google Scholar]
- Grant, PM; Dall, PM; Mitchell, SL; Granat, MH. Activity-monitor accuracy in measuring step number and cadence in community-dwelling older adults. J. Aging. Phys. Act 2008, 16, 201–214. [Google Scholar]
- Benedetti, MG; Di Gioia, A; Conti, L; Berti, L; Esposti, LD; Tarrini, G; Melchionda, N; Giannini, S. Physical activity monitoring in obese people in the real life environment. J. Neuroeng. Rehabil 2009, 6, 1–9. [Google Scholar]
- Huddleston, J; Alaiti, A; Goldvasser, D; Scarborough, D; Freiberg, A; Rubash, H; Malchau, H; Harris, W; Krebs, D. Ambulatory measurement of knee motion and physical activity: preliminary evaluation of a smart activity monitor. J. Neuroeng. Rehabil 2006, 13, 1–10. [Google Scholar]
- Zhang, K; Pi-Sunyer, FX; Boozer, CN. Improving energy expenditure estimation for physical activity. Med. Sci. Sports Exerc 2004, 36, 883–889. [Google Scholar]
- Higashi, Y; Yamakoshi, K; Fujimoto, T; Sekine, M; Tamura, T. Quantitative evaluation of movement using the timed up-and-go test. IEEE. Eng. Med. Biol. Mag 2008, 27, 38–46. [Google Scholar]
- Ní Scanaill, C; Carew, S; Barralon, P; Noury, N; Lyons, D; Lyons, GM. A review of approaches to mobility telemonitoring of the elderly in their living environment. Ann. Biomed. Eng 2006, 34, 547–563. [Google Scholar]
SenseWear | CT1/RT3 | AMP331 | GT3X/GT1M | StepWatch | activPAL | IDEEA | |
---|---|---|---|---|---|---|---|
Size (mm) | 88.4 × 56.4 × 24.1 | 71 × 56 × 28 | 71.3 × 24 × 37.5 | 38 × 37 × 18 | 75 × 50 × 20 | 53 × 35 × 7 | 70 × 54 × 17 |
Weight (g) | 82.2 | 71.5 | 50 | 27 | 38 | 20 | 59 |
Accelerometer type | na | Piezoelectric | na | na | na | piezoresistive | piezoelectric |
Number of accelerometer | 1 | 1 | 2 | 1 | 1 | 1 | 5 |
Number of accelerometer axis | 2 | 1/3 | 1 uni-axis and 1 dual-axis | 3/1 | 2 | 1 | 2 |
Sensor placement | Upper arm | Waist | Ankle | Waist or wrist | Ankle | Thigh | Chest, thigh, feet |
Sampling rate | 32 Hz | 0.017–1 Hz | na | 30 Hz (12 bit) | 128 Hz | 10 Hz (8 bit) | 32 Hz |
Sensitivity range | 2 g | na | na | 0.05–2.5 g | na | 2 g | 5 g |
Battery type | 1.5 V AAA × 1 | 1.5V AAA × 1 | na | 3.7 V Lithium ion/Lithium Polymer | 750 mAh Lithium | 3 V li-polymer rechargeable | 1 1.5 V AA |
Battery life | 3 days (continuous) | 30 days | na | 20 days | na | 7–10 days | 60 hrs |
Data transmission | RF/USB | USB (docking tation) | 916 MHz RF (USB wireless adapter) | USB | USB (docking station) | USB (ducking station) | USB |
Data storage capacity | na | 3 hours to 21 days (dependant on data resolution and collection) | na | 16 MB (or 40 days) | 2 months | na | 7 days |
Reported parameters | EE estimation, activity duration, sleep duration | Activity intensity, EE, MET | Steps, cadence, walking speed, stride length, distance, EE | Activity counts, steps, MET, activity intensity level | Steps gait characteristics | Sedentary and upright time, steps, stepping time, cadence, sit-to-stand activities, MET, PAL, kCal | Activity types, gait types, EE |
© 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
Share and Cite
Yang, C.-C.; Hsu, Y.-L. A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring. Sensors 2010, 10, 7772-7788. https://doi.org/10.3390/s100807772
Yang C-C, Hsu Y-L. A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring. Sensors. 2010; 10(8):7772-7788. https://doi.org/10.3390/s100807772
Chicago/Turabian StyleYang, Che-Chang, and Yeh-Liang Hsu. 2010. "A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring" Sensors 10, no. 8: 7772-7788. https://doi.org/10.3390/s100807772
APA StyleYang, C. -C., & Hsu, Y. -L. (2010). A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring. Sensors, 10(8), 7772-7788. https://doi.org/10.3390/s100807772